Skip to main content

Full text of "Tektronix Manual: Tektronix2000MeasurementProducts"

See other formats


Measurement 

Products Catalog 2000 




Keep Up-to-date with Tektronix 



WWW.TEKTRONIX.COM 




Keep up to date with news from Tektronix via the 
World Wide Web! We publish our press releases in the 
What's New section the day they are released to the 
public, with links to available data sheets, application 
notes, published articles, and upcoming conferences, 
seminars, and shows worldwide. 



Tektronix is on the World Wide Web at: 
www.tektronix.com/Measurement 

Through this site you can access the latest information available 
about Tektronix products. 








CD-ROM* Now Available 

The Tektronix Measurement Catalog is available on CD. 
To order, contact your local Tektronix representative. 

* Availability of the CD-ROM may vary from country to country^ 
Please check with your nearest Tektronix office for details. 



Copyright ® 1999 Tektronix, Inc. All rights reserved. Printed in U.S.A. Tektronix products are covered by U.S. and foreign patents, issued 
and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges 
reserved. TEKTRONIX and TEK are registered trademarks. 

For further information, contact: Tektronix, Inc,, Corporate Offices, 26600 SW Parkway, PO Box 1000, Wilsonville, Oregon 97070-1000. 
Phone (503) 682-3411. (800) 426-2200. Subsidiaries and distributors worldwide. 

Prices and Specifications Subject to Change. 

All prices, specifications and characteristics set forth in this catalog are subject to change without notice. Prices current at the time an 
order is accepted by Tektronix will apply. Check with your local Tektronix representative for current price and specification information. 





Table of Contents 



Alphanumeric Index 

Functional Index 17-24 

New Products/Worldwide Web 25-48 

Measurement Products ........ ................................. 49-672 

Oscilloscopes 

Logic Scope 122 

Logic Analyzers 125 

Spectrum Analyzers 

Network Analyzers 200 

Power Meters 212 

Signal Generators 225 

EMI/RFI Solutions 246 

Wireless Communication Test Sets 266 

Optical Network Products 289 

Broadband Transmission Test Products 33 1 

Access Networks Products 352 

Protocol Analyzers 388 

VXI Systems, Controllers, Software 436 

Arbitrary Generators 

Stimulus Systems 

Data Generator 

PLC Tester 

RMS Multimeters 

Digital Multimeters 104, 479, 481 

Digital Counter 

Function Generators 

Power Supplies 468 

Photometers 

Semiconductor Testers 

Accessories 

Probes/Probe Accessories 

Carts 

Other Accessories 586 

Television Products 

Picture Quality Analysis System 591 

MPEG Test System 

Measurement Sets 593^ 594 

Waveform Monitors/Vectorscopes 597 

Generators/Inserters 601 

Audio 604 

Cable TV Spectrum Analyzer 384 

General Customer Information 612-672 

General Business Information, Terms and Methods of Payment 612 

Rental/Leasing Programs 613 

Federal Government Customers 613 

Technical Support 612, 614, 617 

Service Programs 615-616 

Installation 615-616 

Calibration 615-616 

fest Data 615-616 

On-site Service 615-616 

extended Repair 615-616 

Training/Seminars 617 

Reconditioned Instruments: TekSelect™ 618 

Power Cords/Plugs 619 

Application/Technical Notes 620 

Worldwide Sales/Service Offices 621 

Distributors/Representatives/Rental/Leasing Companies 628, 632 

Price List 635 



New Products ...see pages 25-48 



Prices all in one piace 

All prices have been consolidated 
into one section in the back of the 
catalog instead of appearing on 
individual pages. Makes looking up 
numerous prices easier and faster. 



Your feedback is important to us! 

In the back of the catalog is a 
mini-survey to let us know how 
we are doing and what we can 
provide to meet your changing 
needs. Just complete, mail, fax, 
or provide your input through the 
Tektronix www.tektronix.com site. 




Electronic Products 
Product of the Year Award 






1 





Year 200 0 Co m pliance 



YEAR 2000 INFORMATION AND 
READINESS DISCLOSURE Aa NOTICE 

The statements and information provided 
by Tektronix on this web site, and any 
previous statements by Tektronix con- 
cerning Year 2000 readiness of its prod- 
ucts, are designated as ‘Year 2000 
Readiness Disclosures,’ pursuant to the 
Year 2000 Information and Readiness 
Disclosure Act (RL. 105-271). This is 
Tektronix’ primary, official source of 
information on the company’s Year 2000 
program. Because the contents of this site 
are subject to change without notice, we 
urge vou to register to receive email 
update notices. 

TEKTRONIX' COMMITMENT 

Tektronix has made a corporate commit- 
ment to have its products and support 
systems, both internal and external, 
ready for the year 2000. To carry out 
that commitment, we have established a 
comprehensive program, directed 
through a Year 2000 Program Office, and 
overseen by senior management. 

TEKTRONIX' YEAR 2000 PROGRAM 

Tektronix’ Year 2000 program consists 
of four phases: 

► Strategy & Planning: inventorying 
potential Year 2000 threats and per- 
forming risk assessments 

► Product Readiness: analyzing each 
product to determine if date logic is 
present and, if so. determining if the 
product is Year 2000 Ready 

► Operational Readiness: performing 
remediation and compliance testing 
of internal systems, suppliers, and 
other tliird party service providers 

► Contingency Planning: developing 
contingency strategies that can be 
implemented quickly if a threat is 
realized or a disruption occurs 




2 



www.tektronix.com/Measurement/ 




Tektronix: A Lifetime of Value 



Customer Support 

No other test and measurement supplier 
can match the remarkable depth of cus- 
tomer support offered by Tektronix. We 
offer technical support, service training, 
and service warranties. For additional 
information and the Tektronix represen- 
tative nearest you, see the listing in the 
back of this catalog. 

TEKFAX 

Literature Available Via Fax 

You can now receive information via 
fax — ideal for technical information you 
need immediately. Product information 
or application notes are available any 
time of the day via Tektronix TekFAX. 
See the General Customer Information 
Section for information. 



ilDVANTEST 

In 1993 Tektronix became the exclusive 
distributor of Advantest test and meas- 
urement products in North America. 
Featured in this catalog are a wide- 
range of Advantest products in the 
RF/Microwave and Telecommunications 
areas. These exciting products are highly 
complementary to the Tektronix instru- 
ment portfolio. So look for the Advantest 
logo throughout this catalog to identify 
new high-performance, high-quality 
products from another leading company 
in the Test and Measurement industry. 



ROHDE&SCHWARZ 

In 1993 Tektronix became the exclu- 
sive, marketing distribution service and 
support for Rohde & Schwarz Test and 
Measurement products in North 
America. 



SONY 

Tbktfpnix 

In 1965, Sony /Tektronix was created as 
one of the first Japanese/ American joint 
ventures in Japan. Since then, the com- 
pany has been distributing every 
Tektronix products to Japanese cus- 
tomers including Test and Measurement 
instruments. Color Printers. Video 
Networking products, Computer 
Graphic Terminals. Beside these activi- 
ties, Sony/Tektronix has originally 
designed, manufactured and distributed 
innovative T&M products to worldwide 
customers through Tektronix sales 
channel. These instruments such as 
Arbitrary Waveform Generators, Data 
Generators and Cur\^e Tracers can be 
seen throughout this catalog. 



Tektronix Sales/Service 
Offices 

We have a worldwide network of sales 
and service offices. To find the office 
nearest you, see the listing in the back 
of this catalog. 



Distributor & 

Manufacturers 

Representatives 

We have Authorized Tektronix 
Distributors and Manufacturers 
Representatives for selective products 
and geographic areas. To find the office 
nearest you, see the listing in the back 
of this catalog. 



U. S. Government 
Customers 

Federal Agencies should obtain price 
and delivery from, and place orders 
directly with, Tektronix Federal Order 
Administration. See the General 
Customer Information Section for 
information. 



Reconditioned Products: 
TekSelect™ 

Tektronix has a variety of quality, 
previously used products at prices 
significantly lower than our catalog 
prices. These products have been fully 
refurbished, tested and calibrated. 

Each comes with a warranty equivalent 
to our new products. See the General 
Customer Information Section for 
information. 

World Wide Web 

See Tektronix on the World Wide Web: 
www.tektronix.com 



www.tektronix.com/Measurement/ 



3 



.484 



Alphanumeric Index 



ic-r 



AC220 

ACL21 

ACL22 

ACL23 

ACL24 

AC11 

AC12 

AC13 

AD007 



IDS 200 Soft Case 103 ATL22 

Alligator Clips 404 ATL23 

Hook Clips 

Wire Clips 



484 ATL25 

.484 ATPOl 



Basic Tip 

Extender Reach Tip 484 

Extender Reach Tip 484 

Bead Probe 486 

Audio to Video Delay Measurement Pkg 594 



Jaw Clips 484 AVTIME 

DMM Soft Case 486 AV601A/E/M Digital Audio/Video Monitoring Systems 606 

DMM Soft Case 486 AWC 2005 Arbitrary Waveform Generator 440, 442, 451 

DMM Soft Case 486 AWC 2021 Arbitrary Waveform Generator 440, 442, 449 

GPIB-LAN Adapter 90 AWC 510 Arbitrary Waveform Generator 440, 442, 446 



ADA400A Differential Amplifier 558 AWC 5J0 Arbitrary Waveform Generator 440,442,446 



AFC 310 
AFC 320 
AFTDS 
AMT75 



Arbitrary Function Generator 440, 442, 453 AWC 610 Arbitrary Waveform Generator 440, 442, 443 



Arbitrary Function Generator 440,442,453 A01905 

Electrical Communication Adapter 576 A08012 

Electrical Communication Adapter 576 A08013 

AM 503B Current Probe Amplifier 564, 568 A08014 

AM 503S Current Probe Amplifier System 564, 568 A08017 

AM 5030 Pgm. Current Probe Amplifier 564, 568 A08019 

AM 5030S Pgm. Current Probe Amplifier System 564, 568 A08020 

Handheld Analyzer/Generator 604 A08021 

l/Q Modulation Generator Software 225, 233 A08026 

Audio Signal Generator 604 A08027 

Audio Signal Generator 604 A08028 

Temperature Probe Adapter 486 A08030 

Lead Set A08031 

Lead Set with Probes 484 A08032 



AM70 
AMIQ 
ASC 100 
ASC 140 
ATKOl 
ATLDXl 
ATLOl 
ATL21 



Basic Test Leads 484 A08090 



Sensor Cable 327 

Connector Adapter, FC 325 

Connector Adapter, D4 325 

Connector Adapter, OF2 327 

AC Power Adapter 327 

AC Power Adapter 327 

Bare Fiber Adapter 325 

Adapter Cap 325 

Connector Adapter, Diamond 2.5 327 

Connector Adapter, Diamond 3.5 327 

Connector Adapter, SMA 325 

Connector Adapter, Sumitomo 327 

Connector Adapter, MBO 327 

Connector Adapter, HFBR-4000 327 

Connector Adapter, SC 325 



ALPHANUMERIC INDEX 



Italics and color identifies NEW products. 



Alphanumeric Index 



A08096 Connector Adapter, ST 325 

A0816I Connector Adapter, FC 325 

A08162 Connector Adapter, SC 325 

A08163 Connector Adapter, ST 325 

A08187 Connector Adapter, FC 325 

A1001 Blank Adapter 494 

AI002 In-Line Adapter 494 

A 1003 TD3/TD66 Power Transistor Adapter 494 

A1004 Offset Lead Adapter 494 

A 1005 Axial Lead Diode Adapter 494 

A 1007 Transistor Adapter 494 

A 1009 FET Adapter 494 

A1010 1C Adapter 494 

A1023 SMT Device Adapter 494 

A1024 TD/SMT Device Adapter 494 

A621 Current Probe 487 

A622 Current Probe 487 

A6302 50 MHz AC/DC Current Probe 564, 570 

A6312 100 MHz AC/DC Current Probe 564, 570 

A6302XL Current Probe 564, 570 

A6303XL Current Probe 564, 570 

A6303 15 MHz AC/DC Current Probe 564, 570 

A6304XL Current Probe 564, 570 

A6907 Monolithic Isolator 552, 562 

A6909 Monolithic Isolator 552, 562 

CableScout™ TDR Cable Testers for CATV 376, 378 



CDM250 Digital Multimeter 465, 472 

CFG253 Function Generator 465, 473 

CFG280 Function Generator w/ Counter 465, 473 

CMC251 Frequency Counter w/ Time Base 465, 475 

CMD53 Rohde&Schwarz Communications Test Set 266, 277 

CMD55 Rohde&Schwarz Communications Test Set 266, 277 

CMD57 Rohde&Schwarz Communications Test Set 266, 281 



CMD80 Rohde&Schwarz Communications Test Set 



w/ IS-136 Support 266, 271 

CMM150 AC Clamp Probe 465, 481 

CMU200 Radio Communications Tester 266, 283 

CPS250 Power Supply 465, 469 

CrafTek™ Subscriber Loop Portable Test Set 352, 380 

CRTC02 Rohde&Schwarz Communications Test Set 266, 274 

CSA 803C Communications Signal Analyzer 289, 290 

CTS 55 Rohde&Schwarz Communications Test Set 266, 280 

CIS 710 SONET/DS3/DS1 Test Set 331, 336 

CTS 850 SDH/PDH Jitter Test Set 331, 338 

CT-1 1 GHz Current Transformer 564, 572 

CT-100 CrafTek"” Portable Subscriber Loop Test Set 352, 380 

CT-2 200 MHz Current Transformer 564,572 

CT-6 2 GHz Current Probe 564, 572 

DC2040 Data Generator 455, 459 

DG2020A Data Generator 455, 459 

DG2030 Data Generator 455, 459 

DL-11 Delay Line 120 



Italics and color identifies NEW products. 



ALPHANUMERIC INDEX 



5 



Alphanumeric 


Index 


DMAm/nt 


Digital Modulation Analyzers 


353 


DMMI50 

DMM157 


Ppn Mpfpr 


465, 481 


Handheld Digital Multimeter 


465, 481 


DMM249 


Handheld Digital Multimeter 


465, 481 


DMM254 


Handheld Digital Multimeter 


465, 481 


DMM912 


Digital Multimeter 


465, 479 


DIVIIVI914 


Digital Multimeter 


465, 479 


DMM916 


Digital Multimeter 


465, 479 


DS1001 


M/N Television Demodulator 


608 


DS1002 


B/G Television Demodulator 


608 


DS1003 


1 Television Demodulator 


608 


DS1201/2/3/4/5LOW Cost TV Demodulator System . . 


608 



D3186 Pulse Pattern Generator 331, 332 

D5286 Error Detector 331, 332 

EMC120 EMI Measurement Software 262 

EMI EMI Test Receiver 261 



ESBI Rohde&Schwarz EMI Test Receiver 247 

ESCS30 Rohde&Schwarz EMI Test Receiver 246, 250 

ESHSIO Rohde&Schwarz EMI Test Receiver 246, 252 

ESHS30 Rohde&Schwarz EMI Test Receiver 246, 252 

£5/7 Rohde&Schwarz EMI Test Receiver 247 

ES-Kl Rohde&Schwarz EMI Software 246, 259 

ESMI Rohde&Schwarz EMI Test Receiver 247 

ESN Rohde&Schwarz EMI Test Receiver 255 

ESPC Rohde&Schwarz EMI Test Receiver 246, 260 

ESS Rohde&Schwarz EMI Test Receiver 246, 252 



ESVB Rohde&Schwarz EMI Test Receiver 246, 255 

ESVD Rohde&Schwarz EMI Test Receiver 246, 255 

ESVN20 Rohde&Schwarz EMI Test Receiver 246, 255 

ESVN30 Rohde&Schwarz EMI Test Receiver 246, 255 

ESVSIO Rohde&Schwarz EMI Test Receiver 246, 252 

ESVS30 Rohde&Schwarz EMI Test Receiver 246, 252 

FSIQ3 Signal Analyzer 145,156 

FSIQ7 Signal Analyzer 145, 156 

FSIQ26 Signal Analyzer 145, 156 



FiberMaster R Optical Time Domain Reflectometer 352, 359 

FMTAP™ OTDR Trace Analysis Software Ver. 3.0 352, 361 

FSEA20 Rohde&Schwarz Spectrum Analyzer 145, 147, 160 

FSEA30 Rohde&Schwarz Spectrum Analyzer 145, 147, 160 

FSEB20 Rohde&Schwarz Spectrum Analyzer 145, 147, 160 

FSEB30 Rohde&Schwarz Spectrum Analyzer 145, 147, 160 

FSEK20 Rohde&Schwarz Spectrum Analyzer 145, 146, 160 

FSEK30 Rohde&Schwarz Spectrum Analyzer 145, 146, 160 

FSEM20 Rohde&Schwarz Spectrum Analyzer 145, 146, 160 

FSEM30 Rohde&Schwarz Spectrum Analyzer 145, 146, 160 

gigaBERT CB700 Pattern Generator & Error Detector 331, 348 

gigaBERT GB1400 Pattern Generator & Error Detector 331, 348 

GTS1250 Ethernet GBIC Test System 289, 301 

HFS 9DG1 Data Time Generator Card 455, 456 

HFS 9DG2 Data Time Generator Card 455, 456 

HFS 9003 Stimulus System 455, 456 

HFS 9009 Stimulus System 455, 456 



6 



ALPHANUMERIC INDEX 



Italics and color identifies NEW products. 



Alp ha n um eric Index 



J17 TekLumaColor™ Photometer 465, 488 

JI8 TekLumaColor™ Photometer 465,488 

J1803 Luminance Head 465, 488 

J1810 Color Head 465, 488 

J1811 Illuminance Head 465, 488 

J1820 Color Head 465, 488 

K1103 Protocol Tester 388, 391 

K1205 Protocol Tester 388, 396 

K1297 Protocol Tester 388, 401 

K1297 ATM ATM Protocol Tester Software 388, 409 

K1297 CPR5 GPRS Protocol Tester Software 388, 408 

K1297 ISDN ISDN Software for K1297 388, 411 

K1297 PSI5DN Packet Services for ISDN Software for K 1297 388, 417 

K1297 MRN Mobile Radio Network Software for K1297 388, 420 

K1297 GSM Data Services for GSM Software for K1297 388, 416 

K1297 SS#7 SS#7 Software for K1297 388, 422 

K1297TT Test Tools 388,418 

K1297 V5.1/V5.2 

V5.1/V5.2 Software for K1297 388, 421 

K1403 ISDN SO Analyzer 388, 424 

K1404 ISDN U Analyzer 388, 427 

K1405 ISDN SO Simulator/Monitor 388, 430 

K212 Portable Instrument Cart 582, 585 

K415 Transport Cart 582, 584 

K420 Work Bench Cart 582, 583 

K465 Instrument Tower 582, 583 



K475 Workstation Tower 582, 584 

LPBnoo Tunable Laser Sources 289, 303 

LPB1300 Tunable Laser Sources 289, 303 

LPBI550 Tunable Laser Sources 289, 303 

LPM5000 Modular Laser-source Mainframe 289, 306 

LPM5200 Modular Laser-source Mainframe 289, 306 

LPM5500 Modular Laser-source Mainframe 289, 306 

LPM5700 Modular Laser-source Mainframe 289, 306 

MCTAP Metallic Cable Trace Analysis Package 352, 370 

MCCS Mobile Call Generation System 266, 269 



MTS205 Real-Time Analyzer 592 

M2T300 Trunking Video Edge Device 610 

MTS210 Deferred-Time Analysis System and 

Transport Stream Generator 592 

MTS215 MPEG Test System 592 

M366PIUS GSM Network Service Analyzer 267 

NAP Rohde&Schwarz Power Reflection Meter 213 

NAP-Z3 Power Sensor 213 

NAP-Z4 Power Sensor 213 

NAP-Z5 Power Sensor 213 

NAP-Z6 Power Sensor 213 

NAP-Z7 Power Sensor 213 

NAP-Z8 Power Sensor 213 

NAP-Z9 Power Sensor 213 

NAP-Z10 Power Sensor 213 

N AP-Z 1 1 Power Sensor 213 



Italics and color identifies NEW products. 



ALPHANUMERIC INDEX 



7 



Alphanumeric Index 



NAP-Z42 Power Sensor 213 

NAS Rohde&Schwarz Directional Power Meter 222 

NAS-Z1 RF Insertion Unit 222 

NAS-Z2 RF Insertion Unit 222 

NAS-Z3 RF Insertion Unit 222 

NAS-Z5 RF Insertion Unit 222 

NAS-Z6 RF Insertion Unit 222 

NAS-Z7 RF Insertion Unit 222 

Net-C Monitoring System 389 

NRT Power Meter 213 

NRT-Z4J Power Sensor 213 

NRVD Rohde&Schwarz Dual-CH RF Meter 212, 218 

NRVS Rohde&Schwarz RF Power Meter 212, 220 

NRV-Z1 Power Sensors 222 

NRV-Z2 Power Sensors 222 

NRV-Z3 Power Sensors 222 

NRV-Z4 Power Sensors 222 

NRV-Z5 Power Sensors 222 

NRV-Z6 Power Sensors 222 

NRV-Z7 Power Sensors 222 

NRV-Z8 Power Sensors 222 

NRV-Z15 Power Sensors 222 

NRV-Z31 Power Sensors 222 

NRV-Z51 Power Sensors 222 

NRV-Z52 Power Sensors 222 

NRV-Z53 Power Sensors 222 



NRV-Z54 Power Sensors 222 

NRV-Z55 Power Sensors 222 

OA5002 Optical Attenuator 289, 320 

OA5012 Optical Attenuator 289, 320 

OA5022 Optical Attenuator 289, 320 

OA5032 Optical Attenuator 289, 320 

ORR24 Optical Reference Receiver 289, 297 

ORS20 Optical Receiver System 289, 299 

PacketBERT PB200 Packet Generator & Error Detector 331, 350 

PPM203B Articulated Arm 535 

PPM207 Probe Buddy 535 

PQA200 Picture Quality Analysis System 591 

PS2520G Programmable Power Supply 465, 470 

PS2521G Programmable Power Supply 465,471 

PS280 Triple Output Power Supply 465,468 

P30W 100 MHz, lOX Probe 523, 524 

P3410 m Level Pod 455, 459 

P3420 Variable Level Pod 455, 459 

P5100 250 MHz, 2.5 kV, lOOX Probe 553 

P5102 100 MHz, 1 kV High Voltage Probe 527, 553 

P5200 Active Differential Probe 560 

P5205 Active Differential High Voltage Probe 560 

P5210 Active Differential High Voltage Probe 560 

P6015A 75 MHz, 40 kV, lOOOX Probe 553 

P6021 60 MHz Current Probe 564, 574 

P6022 120 MHz Current Probe 564, 574 



8 



ALPHANUMERIC INDEX 



Italics and color identifies NEW products. 



Alphanumeric Index 



P6101B 15 MHz, IX Probe 523, 524 

P6103B 60 MHz, lOX Probe 523, 524 

P6105A 100 MHz, lOX Probe 523, 526 

P6106A 250 MHz, lOX Probe 523, 526 

P6109B 100 MHz, lOX Probe 523, 524 

P6111B 200 MHz, lOX Probe 523, 524 

P6I12 100 MHz, lOX Probe 523, 524 

P6114B 400 MHz, lOX Probe 523, 524 

P6I17 200 MHz, lOX Probe 523, 524 

P6119B 1 VlOX Switchable Probe 523, 524 

P6122 100 MHz, lOX Probe 526 

P6129B iX/lOX Switchable Probe 523, 524 

P6I31 300 MHz, lOX Probe 529 

P6I33 150 MHz, lOX Probe 529 

P6134C 400 MHz, lOX Probe 529 

P6135A 150 MHz, lOX Passive Differential Probe Pair 559 

P6136 350 MHz, lOX Probe 529 

P6137 400 MHz, lOX Probe 529 

P6138A 400 MHz, lOX Probe 529 

P6139A 500 MHz, lOX Probe 529 

P6150 9 GHz, High BW, Low Impedance Probe 520 

P6158 3 GHz, 20X, Low Capacitance Probe 521 

P6201 900 MHz, IX/IOX/IOOX, FET Probe 510, 518 

P6202A 500 MHz, lOX/lOOX, FET Probe 510, 518 

P6204 1 GHz, lOX, FET Probe 510, 516 

P6205 750 MHz, lOX, FET Probe 510, 516 



P6243S Active Probe System 510, 514 

P6243 1 GHz Active Probe 510, 514 

P6245 1.5 GHz, FET Probe 510, 512 

P6246 Active Differential Probe 555 

P6247 Active Differential Probe 555 

P6248 Active Differential Probe 555 

P6249 4 GHz, Active Probe 510, 512 

P6339A Buffered Passive Probe 531 

P6408 Word Recognizer Probe 575 

P6561 A 200 MHz, lOX SMD Probe 533 

P6562A 350 MHz, lOX SMD Probe 533 

P6563A 500 MHz, 20X SMD Probe 533 

P6701B Optical-Electrical Converter 289, 293 

P6703B Optical-Electrical Converter 289, 293 

P6711 Optical-Electrical Converter 289, 293 

P6713 Optical-Electrical Converter 289, 293 

P6723 Optical-Electrical Converter 289, 293 

Q7606A Optical Chipform Test Set 289, 313 

Q7606B Optical Chipform Test Set 289, 313 

Q7750 Optscope Optical Network Analyzer 289, 328 

Q81201 LED Source 322 

Q81202 LED Source 322 

Q81203 LED Source 322 

Q81204 LED Source 322 

Q81205 LED Source 322 

Q81206 LED Source 322 



Italics and color identifies NEW products. 



ALPHANUMERIC INDEX 



9 



Alp h anume ric Index 



Q81207 LED Source 322 

Q81211 Laser Diode Source 322 

Q81212 Laser Diode Source 322 

Q8/6J Optical Polarization Scrambler 289, 318 

Q8221 Advantest Optical Power Multimeter Mainframe 289, 322 

Q82214 Power Sensor, Short Wavelength 322 

Q82215 Power Sensor, Long Wavelength 322 

Q82216 Power Sensor, Large Area, High Sensitivity 322 

Q82227 Power Sensor, Long Wavelength, High Power 322 

Q8344A Advantest Optical Spectrum Analyzer 322 

Q8347 Advantest Optical Spectrum Analyzer 289, 314 

RFA300 8VSB Measurement Set 593 

RFM151 SignalScour” Cable TV RF Analyzer 352, 382 

RJIJI Spectrum Analyzer 145, 148, 192 

R3132 Spectrum Analyzer 145, 148, 185 

R3I32N Spectrum Analyzer 145, 148, 185 

R3162 Spectrum Analyzer 145, 148, 185 

R3263 Advantest Spectrum Analyzer 145, 147, 176 

R3267 Spectrum Analyzer 145, 147, 170 

R3272 Advantest Spectrum Analyzer 145,146,174 

R3273 Spectrum Analyzer 145, 146, 170 

R3463 Advantest Spectrum Analyzer 145, 147, 176 

R3465 Advantest Spectrum Analyzer 145, 147, 176 

R 3561 /R 3561 L Advantest Source Simulation 145, 180 

R3754A Network Analyzer 200,211 

R3754B Network Analyzer 200,211 



R3765AH Advantest Network Analyzer 200, 207 

R3765BH Advantest Network Analyzer 200, 207 

R3765CH Advantest Network Analyzer 200, 207 

R3767AH Advantest Network Analyzer 200, 207 

R3767BH Advantest Network Analyzer 200, 207 

R3767CH Advantest Network Analyzer 200, 207 

SD-14 High Impedance Probe Sampler 116 

SD-20 Loopthrough Sampling Head 116 

SD-22 Low Noise Sampling Head 116 

SD-24 TDR Sampling Head f 16 

SD-26 Sampling Head H6 

SD-32 Sampling Head H6 



SD-42 Optical to Electrical Converter 116, 289, 295 

SD-43 Optical to Electrical Converter 289, 295 

SD-44 Optical to Electrical Converter 116, 289, 295 



SD-48 Optical to Electrical Converter 289, 295 

SD-51 20 GHz Trigger Head H6 

SF201 A SureFoot R Interconnect for FET Probes 535 

SF202A SureFoot R Interconnect for FET Probes 535 

SF203A SureFootl Interconnect for FET Probes 535 

SF501 SureFoot R Interconnect for SMD Probes 535 

SF502 SureFoot! Interconnect for SMD Probes 535 

SF503 SureFoot R Interconnect for SMD Probes 535 

SignalScout^ RFM 151 Cable TV RF Analyzer 352,382 

SlU 800 Static Isolation Unit 120 

SJ300E SDH/SONET Jitter and Wander Analyzer 331, 346 



10 ALPHANUMERIC INDEX 



Italics and color identifies NEW products. 



Alp hanumeric Index 

SMCKl SOIC Clips 535 



SME02 Rohde&Schwarz 1.5 GHz Signal Generator 225, 226, 244 

SME03 Rohde&Schwarz 3 GHz Signal Generator 225, 226, 244 

SME06 Rohde&Schwarz 6 GHz Signal Generator 225, 226, 244 

SMG50 SMT KlipChip^ Pkg 535 

5MIQ02B Rohde&Schwarz Signal Generator 225, 226, 227 

5MIQ0JB Rohde&Schwarz Signal Generator 225, 226, 227 

SIVIK4 Micro KlipChip Adapter 535 

SMP02 Rohde&Schwarz 20 GHz Signal Generator 225, 226, 240 

SMP03 Rohde&Schwarz 27 GHz Signal Generator 225, 226, 240 

SMP04 Rohde&Schwarz 40 GHz Signal Generator 225, 226, 240 

SMP22 Rohde&Schwarz 20 GHz Signal Generator 225, 226, 240 

SMQK1 PLCC Quad Kits 535 

SMR20 Signal Generator 225, 226, 236 

SMR27 Signal Generator 225, 226, 236 

5MR40 Signal Generator 225, 226, 236 

SMT02 Rohde&Schwarz 1.5 GHz Signal Generator 226, 242 

SMT03 Rohde&Schwarz 3.0 GHz Signal Generator 225, 226, 242 

SMT06 Rohde&Schwarz 6.0 GHz Signal Generator 225, 226, 242 

SPG 1000 HDTV Sync Generator 602 

SPG- 170 A NTSC Sync Generator 602 

SPG-271 PAL Sync Generator 602 

SPG 422 Component Digital Sync Generator 602 

ST501 SureFoot'R Interconnect for SMD Probes 535 

ST112 Portable SONET Transmission Tester 331, 341 

ST2400A 2.4 Gb/s SDH/SONET Test Set 331, 343 



SureFoot r Surface Mount Device Interconnects 535 

S3FT400 WaveWrlter^ System Software 441 

TCP202 50 MHz Current Probe 564,566 



TD5CEM1 Communications Eye Diagram Measurement Software 82 



TDSCPM1 Communications Pulse Measurement Software 83 

TDSDMM1 Disk Drive Measurement Software 85 

TDSJITI Jitter Analysis Software 81 

TD5PSM1 Processor Specification Measurement Software 84 

TDSPWR1 Power Measurement Software 86 

TDSPRT1 Enhanced Printing Utility Software 87 

TDS2CIVI Communications Extension Module 101 

TDS2HM Hardcopy Extension Module 101 

TDS2MM Measurement Extension Module ; .101 

IDS 210 60 MHz Digital Storage Oscilloscope 50, 60, 66, 101 

IDS 220 100 MHz Digital Storage Oscilloscope 50, 60, 66, 101 

TD5 224 100 MHz Digital Storage Oscilloscope 50, 60, 66, 101 

TD5 JTMT Telecom Mask Test Module 96, 100 

TDS 3FFT FFT Application Module 96, 100 

TDS 3STRC Advanced Trigger Application Module 96, 100 

TDS 3VID Extended Video Application Module 97, 100 

TDS 3EM lOBaseT Ethernet and RS-232 Interface 100 

TDS 3CM GPIB and RS-232 Interface 99, 100 

TDS 3VM VGA Port and RS-232 Interface 99, 100 

TDS 3BAT Battery Pack 

TDS 3012 100 MHz Digital Phosphor Oscilloscope 50, 60, 66, 

TDS 3014 100 MHz Digital Phosphor Oscilloscope 50, 60, 66, 95 



Italics and color identifies NEW products. 



ALPHANUMERIC INDEX 11 



.352, 359 



A L P H A N U MER 1C INDEX 



TD5 5052 


300 MHz Digital Phosphor Oscilloscope — 


50, 60, 66, 95 


TFP2A 


JDS 5054 


300 MHz Digital Phosphor Oscilloscope . . . . 


50, 60, 66, 95 


TFS3031 


TD5 5052 


500 MHz Digital Phosphor Oscilloscope . . . . 


50, 60, 66, 95 


TG2000 


TD5 5054 


500 MHz Digital Phosphor Oscilloscope — 


50, 60, 66, 95 


THS7BAT 


TDS 420A 


200 MHz Digitizing Oscilloscope 


50, 60, 66, 92 


THS7CHG 


TDS 430A 


400 MHz Digitizing Oscilloscope 


50, 60, 66, 92 


THS7HCA 


TDS 460A 


400 MHz Digitizing Oscilloscope 


50, 60, 66, 92 


THS710A 


TDS 520D 


500 MHz Digital Phosphor Oscilloscope . . . . 


50, 60, 62, 68 


THS720A 


TDS 540D 


500 MHz Digital Phosphor Oscilloscope . . . . 


50, 60, 62, 68 


THS720P 


TDS 580D 


1 GHz Digital Phosphor Oscilloscope 


50, 60, 62, 68 


THS730A 


TDS 654C 


500 MHz Digitizing Oscilloscope 


50, 60, 64, 77 


TLA7I4 


TDS 680C 


1 GHz Digitizing Oscilloscope 


50, 60, 64, 77 


TLA720 


TDS 684C 


1 GHz Digitizing Oscilloscope 


50, 60, 64, 77 


TLS 216 


TDS 694C 


3 GHz Digitizing Oscilloscope 


50, 60, 64, 77 


TOP130 


TDS 724D 


500 MHz Digital Phosphor Oscilloscope . . . 


50, 60, 62, 68 


TOP140 


TDS 754D 


500 MHz Digital Phosphor Oscilloscope . . . 


50, 60, 62, 68 


TOP160 


TDS 784D 


1 GHz Digital Phosphor Oscilloscope 


50, 60, 62, 68 


TOP200 


TDS 794D 


2 GHz Digital Phosphor Oscilloscope 


50, 60, 62, 68 


TOP220 


TDS 820 


6 GHz Digitizing Oscilloscope 


50, 60, 64, 88 


TOP300 


TekRanger R 


2 TFS5031 Mini OTDR 


352, 363 


TOP400 


TekScopeR 


THS710A Handheld Battery Operated Oscilloscope/DMM . . .50, 104 


TPG20 


TekScopeR 


THS720A Handheld Battery Operated Oscilloscope/DMM . . .50, 104 


TQ82014 


TekScopeR 


THS720P Handheld Battery Operated Oscilloscope/DMM . . .50, 104 


TQ82015 


TekScope r 


THS730A Handheld Battery Operated Oscilloscope/DMM . . .50, 104 


TQ82017 


TelScoutR 


TDR Telephone Cable Testers 


. . . .352, 368, 371, 373 


TQ82018A 


Test Station 


Instrument Workstation 


582, 585 


TQ8210 



FiberMaster R OTDR 
TekRanger™ 2 Mini Optical Time Domain Reflectometer . . .352, 363 

Signal Generator 602 

Ni-Cad Battery Pack 106 

Battery Charger 106 

Hard Carrying Case 106 

60 MHz Handheld Battery Operated Oscilloscop^DMM — 50, 104 



100 MHz Handheld Battery Operated Oscilloscope/DMM . . .50, 104 
100 MHz Handheld Battery Operated Oscilloscope/DMM . . .50, 104 
200 MHz Handheld Battery Operated Oscilloscope/DMM . . .50, 104 



Portable Color Logic Analyzer Mainframe 125 

Benchtop Color Logic Analyzer Mainframe 125 

Logic Scope 122 

LED Optical Source 352, 355 

LASER Optical Source 352, 355 

LASER Optical Source 352, 355 

Optical Power Meter 352, 355 

High Performance Optical Power Meter 352, 355 

Visual Fault Finder 352, 355 

Optical Attenuator 352, 355 

Test Pattern Generator 602 

Power Sensor, Short Wavelength 289, 326 

Power Sensor 289, 326 

Power Sensor, Thin Wand 289, 326 

Power Sensor, Thin Wand 289, 326 

Advantest Handheld Optical Power Meter 289, 326 



12 



ALPHANUMERIC INDEX 



Italics and color identifies NEW products. 



Alphanumeric Ind ex 



TQ8325 Advantest Optical Wavelength Meter 289, 316 

TR 210 Huntron Tracker R 466 

TS 90 TDR Telephone Cable Testers 352, 371 

TS 100 TDR Telephone Cable Testers 352, 368 

TS 200 Access Network Analyzer 352, 373 

TSC 95 PAL/NTSC Signal Generator 602 

TSC 100 NTSC Signal Generator 602 

TSC 111 PAL Signal Generator 602 

TSC 130A NTSC Multiformat Generator 602 

TSC 131 A PAL Multiformat Generator 602 

TSC 170A TV Test Signal Generator 603 

TSC 170D Digital Composite Generator 603 

TSC 200 NTSC Signal Generator 603 

TSC 271 PAL TV Generator 603 

TSC 422 Digital Component Generator 603 

TSC 601 Handheld Serial Component Generator 603 

TS90 TelScouf" Cable Tester for Telephone Applications 371 

TSIOO TelScout ® TDR Telephone Cable Tester 368 

TVS621A VXI Waveform Analyzer 439 

TVS625A VXI Waveform Analyzer 439 

TVS641A VXI Waveform Analyzer 439 

TVS645A VXI Waveform Analyzer 439 

TV90 CableScout™ TDR Cable Tester for CATV 352, 378 

TV220 CableScour TDR Cable Tester for CATV 352, 376 

TV1340 Test Demodulator 608 

TV1350 Test Receiver and Demodulator 608 



TXl True RMS Digital Multimeter 465, 477 

TX3 True RMS Digital Multimeter 465, 477 

UPDOS Audio Analyzer 266, 285 

UPL06 Audio Analyzer 266,286 

UPL16 Audio Analyzer 266,288 

UPL66 Audio Analyzer 266,288 

URV-Z3 RF Probes 222 

URV-Z50 RF Probes 222 

URV 35 Rohde&Schwarz RF Millivoltmeter 212, 216 

URV 5 Rohde&Schwarz RF Millivoltmeter 212, 216 

URV5-Z1 RF Probes 222 

URV5-Z2 RF Insertion Unit 222 

URV5-Z6 RF Probe 222 

URV 5-Z7 RF Probe 222 

URV 5-Z44 RF Insertion Unit 222 

URV 5-Z47 RF Insertion Unit 222 

U3641 Advantest Spectrum Analyzer 145,148,188 

U3641N Advantest Spectrum Analyzer 145,148,188 

U3661 Spectrum Analyzer 145, 148, 182 

VITS 100 NTSC Generator/Inserter 603 

VITS 200 NTSC Generator/Inserter 603 

VITS 201 Insertion Generator 603 



Italics and color identifies NEW products. 



ALPHANUMERIC INDEX 13 



Alphanumeric Index 



VMBKUP Backup and Remote Control Software 594 

VMREMGR Remote Graphics Software 594 

VMT Remote Control Software 594 

VM100 Video Measurement Set 594 

VM101 Video Measurement Set 594 

VM700T Video Measurement Set 594 

VX1410A VXI C-Size Mainframe 439 

VX1411A VXI C-Size Mainframe 439 

VX1420A VXI C-Size Mainframe 439 

VX4101A MultiPaq™ Instrument 437, 438 

VX4240 VXI Waveform Digitizer/Analyzer Module 439 

VX4244 Digitizer 439 

VX4286 Digital Input/Analog Comparator 438 

VX4287 VXI Differential Input A/D Converter 438 

VX4320 Six 1x4 RF Multiplexer 437 

VX4330 Scanner/Multiplexer 437 

VX4350 Switching Module 437 

VX4351 Switching Module 437 

VX4357 SPDT Relay Switch 437 

VX4380 Matrix 437 

VX4428 ARINC 429 Quad Transmitter/Receiver 437 

VX4469A ARINC 629 Simulator w/ Enhanced Error Injection 437 

VX4730 12 Channel DAC 438 

VX4750 Function Generator 438 

VX4780 Digitizer 439 

VX4790A Arbitrary Waveform Generator 438 



VX4801 Isolated Digital I/O 438 

VX4802 Programmable Digital I/O 438 

WaveStar™ Oscilliscope Software 109 

WaveWriter^ Waveform Editing Software 441 

WFM1125 Digital Television Waveform Monitor 597 

WSTR31 WaveStar™ Electronic Lab Notebook Software 109 

WSTRM WaveStar"*" Software for Meters 109 

WSTRO WaveStar™ Software for Oscilloscopes 109 

WFM 300A Component/Composite TV Waveform Monitor 597 

WFM 601 A Serial Component Monitor 597 

WFM 601 E Serial Component Monitor with Eye Pattern 597 

WFM 601 M Serial Component Measurement Set 597 

WFM 90 Waveform/Vector/Picture/Audio Monitor (NTSC) 597 

WFM 91 Waveform/Vector/Picture/Audio Monitor (PAL) 597 

WVR 500 Waveform/Vector Rasterizer 597 

YT5060 IX/lOX 60 MHz Passive Probe 528 

ZVR Network Analyzer 201 

1101 A Probe Power Supply 510, 516 

1103 TEKPROBEI) Power Supply 510, 516 

11801C Digital Sampling Oscilloscope 50, 112, 113 

1502C TDR Cable Testers 352,366 

1503C TDR Cable Testers 352,366 

1705A Spectrum Monitor 599 

1710J Waveform Monitor for NTSC 599 

171 1J Waveform Monitor for PAL 599 

1720 Vectorscope for NTSC System AppI 599 



14 ALPHANUMERIC INDEX 



Italics and color identifies NEW products. 



Alphanumeric Index 



1720 SCH Vectorscope with SCH (NTSC) 599 

1721 Vectorscope for PAL System AppI 599 

1721 SCH Vectorscope with SCH (PAL) 599 

1725 Vectorscope for PAL/NTSC 599 

1730 Waveform Monitor NTSC System AppI 599 

1730 D NTSC Digital Waveform Monitor 599 

1731 Waveform Monitor for PAL System AppI 599 

1735 Waveform Monitor for PAiyNTSC 599 

1735 HD HDTV Waveform Monitor 599 

1740A NTSC Waveform/Vector Monitor 599 

1741 A PAL Waveform/Vector Monitor 599 

1745A NTSC/PAL Waveform/Vector Monitor 599 

1750A NTSC Waveform/Vector/SCH Monitor 599 

1751 A PAL Waveform/Vector/SCH Monitor 599 

1755A NTSC/PAL Waveform/Vector/SCH Monitor 599 

1760 NTSC/Component Waveform/Vector Monitor 599 

1761 PAL/Component Waveform/Vector Monitor 599 

1765 NTSC/PAL/Component Waveform/Vector Monitor 599 

1780R Video Measurement Set 594 

1781 R Video Measurement Set 594 

2704 Inverter 198 

2705 Battery Pack 198 

2706 Stepping RF Preselector 246, 264 

2707 External Tracking Generator 199 

2711 Portable Spectrum Analyzer 145, 149, 194 

2712 Portable Spectrum Analyzer 145, 149, 194 



27I20B EMI Measurement System 246, 262 

2711/2712/ 

2715 Opt. 05 Tracking Generator 199 

2715 CATV Spectrum Analyzer 149, 382, 384 

J026 Spectrum Analyzer 145, 153 

S066 Spectrum Analyzer 145, 150 

3086 Spectrum Analyzer 145, 150 

370A Programmable Curve Tracer 491 

371 A Programmable Curve Tracer 491 

73A270 VXI Pulse/Pattern Generator 438 

73A308 VXI Relay Driver Module 437 

73A455 MIL-STD-1553 Simulator Tester 437 

760A Stereo Audio Monitor 604 

764 Digital Audio Monitor 604 



Italics and color identifies NEW products. 



ALPHANUMERIC INDEX 15 



Functional Index 



A 

Access Networks Products 352 

Accessories 495-589 

ATM Protocol Tester 401-409 

Bit Error Rate Test Set 348-351 

Cable Testing, Metallic 366 

Cable Testing, Optical 359, 363 

Communications Signal Analyzer 68, 271, 290 

ISDN Analyzers 388-432 

ISDN Service Set 388 

ISDN Simulator/Monitor 388 

LAN Media Testing 366 

Metallic Cable Testers 366 

Modulation Analyzers 160, 176 

Optical Attenuator 320 

Optical Cable Testing 359, 363 

OptIcal-to-Electrical Converters 116, 293, 295 

Optical Probes 293 

Optical Spectrum Analyzers 314 

Optical Wavelength Meter 316 

Probes 495 

Protocol Tester 388 

Protocol Tester Software 388 

RS-232 Analyzer 125 

SDH/PDH Test Set 338 

SDH/SONET Analyzer 346 

SDH/SONET Jitter and Wander Analyzer 338 

SDH/SONET Test Set 341-345 

SONET Test Set 336 

Spectrum Analyzers 145-199, 262, 314 

Waveform Analyzer 125 

Accessories 495-589 

Accessory Pouch 586 

Adapters 578 

Antennas 265 

Attenuators 518, 580 

Capacitors, Coupling 580 

Carrying Cases 586 

Carts 582-585 

Cathode-Ray Tube Light Filters 589 

Coaxial Cables 578 

Connectors, Coaxial 578 

Converter Probes (Optical) 293 



Delay Lines (SMA) 580 

EMC Screen Filters 589 

Fiber Optic Cables 294 

Filters, Light/Mesh 589 

GPIB Cables 578 

Ground Leads, Probes 540-551 

Interface Cables (RS-232C, GPIB, Centronics) 578, 579 

Isolators 562 

Light Filters 589 

Meter Leads 578 

Optical-to-Electrical Converter 293 

PLCC. SOIC Clips 535 

Power Dividers (SMA) 579, 580 

Power Supplies 469-471, 516, 518 

Probe Accessories 542-551, 578, 579 



Product Accessories see Individual Product Pages 



Rackmount Kits 588 

SMD Attachments 535 

Terminations 580 

Test Leads 578 

Transit (Carrying) Cases 586 

Active Probes (FET, Bipolar) 510-519, 535 

Adapters 

Bare Fiber, Optical 326 

BNC 579 

Cables, Fiber Optic 294 

Connector, Optical Fiber 326 

F 579 

GR 579 

Kits 579-581 

N 579 

Optical Fiber 326 

Probe 540-551, 579-581 

SMA (3 mm and 3.5 mm) 546, 548 

Amplifiers, Piug-ln 

Differential Preamplifier 558 

Operational 568 

Analyzers 

Audio 604 

Cable TV Spectrum 384 

Communications Signal 290 

Eye Diagram 68, 290, 597 

Handheld, Audio Monitor 597, 606 



16 FUNCTIONAL INDEX 



Functional Index 



Logic 

Measurement Sets 

Modulation 

Network 

Optical Spectrum 

SDH/SONET 

Spectrum 

Waveform 

Antennas 

Application Notes Listing 

Arbitrary Generators 

Attenuators 

Electrical 

Optical 

Audio 

Analyzer/Cenerator, Digital 

Audio Measurement Set 

Handheld Monitor 

Signal Generators 

Stereo Audio Monitors 

B 

Battery Operated Instruments 

Battery Pack 

Bench Test Instruments 

Bit Error Rate Testers 

BNC 

Adapters 

Attenuators 

Cables 

c 

Cables 

BNC, BSM, SMA (3 mm and 3.5 mm) . . . 

Coaxial 

GPIB Interface (RS-232, GPIB, CentroniG) 

Optical Fiber 

Patch Cords 

Cable Testers 

Metallic 

CATV/Broadband Sweep 



125 

594 

. . . .147, 176 

200 

314 

. . . .336-342 
144-199, 314 
439 

265 

620 

440 

320 

580 

320 

604 

594 

. . .597, 604 

601 

604 



,104,182,188,477-483, 
597, 601, 602, 604 

198 

465-487 

348-351 



.579-581 
. . . .580 
. . . .578 



.579-581 

578 

578 

.294, 578 
578 

366 

384 



Cable TV Measurement Spectrum Analyzer 384 

Cable TV Measurements 384 

Cable TV, RF Spectrum Analyzer Optical Plug-in 314 

Cable TV/RF 

Demodulators 608 

Signal Generator 601-603 

Signal Level Meters 382 

Calibration Services 616 

Camera Measurement Set 594 

Capacitors, Coupling (SMA) 580 

Card Modular Systems (VXI) 436 

Carrying Cases 586 

Carts 582-585 

CATV 384 

Centronics Cables 578 

Coaxial Cables 578 

Colorimeters 488 

Communication Interfaces 
GPIB 

Communication Test Sets 144-199, 266-288 

EMI Field Strength 246 

EMI/Radio Monitoring Solutions 255 

GPIB-LAN Adapter 90 

Logic Analyzers 125 

Logic Scope 122 

Oscilloscopes 49-121 

Power Meters 212-224 

Preselector 264 

Signal Sources 225-245, 440-454 

Spectrum Analyzers 145-199 

RS-232 

EMI/RFI Solutions 246 

Oscilloscopes 25 

Power Meters 212-224 

Signal Sources 225-245, 440-454 

VXI 436-439 

Communications Signal Analyzers 290 

Communications Test Equipment see Access Network 352 

Communications Test Sets 266-288 

Component Checker, Handheld 472, 479 



FUNCTIONAL INDEX 17 



Functional Index 



Component Tester 

Connectors 

Converters 

Optical-to-Electrical 

Tunable/Fixed Down Converter, Television RF — 

Counters 

Coupling Capacitors (SMA) 

Current Measurements 

Current Probes 

Curve Tracers 

Adapters 

Customer Information 

Application/Technical Notes 

Calibration Services 

Customer Support 

Federal Customers 

General Business Information 

Leasing Program 

Order Information see Individual Product Pages 

Power Cords/Plugs 

Pricelist 

Reconditioned Instruments: TekSelect™ 

Rental Program 

Repair 

Sales & Service Location Listing 

Service 

Technical Support 

Terms and Methods of Sale 

Training 

Upgrade Services 

Warranty — 

Customer Service/Support 

Customer Training 

D 

Data Generators (a!so see Generators) 

Data Time Generators see Generators 

DC Coupled Current Probe 

Delay Lines (SMA) 

Demodulators, Television 

Differential Preamplifier 



.... 472 , 479 
579 

. 293 - 300 , 320 
608 

475 

580 

564 

564-574 

490 

494 

612-620 

620 

616 

614 

613 

612 

613 

619 

633 

618 

613 

615 , 616 

621 

615 , 616 

614-617 

612 

617 

615 , 616 

612 

612-620 

617 

459 

564 , 566 

580 

608 

558 



Differential Probes 

Digital Multimeters (DMM) 

Handheld Digital Multimeters . . 
Bench Digital Multimeters 

Digital Signal Analyzers 

Digital Signal Processing Systems 

Analyzers 

Oscilloscopes 

Spectrum Analyzers 

Digital Test Instruments 

Digitizers also see Oscilloscopes 

Logic Analyzer Based 

VXI 

Waveform 

Diode, Edge Emitting 

Distributors 

Down Converters, Television RF ... 

E 

EMC Screen Filters 

EMI, Field Strength 

EMI Measurement Systems 

EMI/Radio Monitoring 

EMI/RFI Solutions 

EMI Test Software 

Encoder, PAL 

Error Detector, SDH/SONET.. 

F 

FET Probe Tutorial 

FET Probes 

Fiber Adapter, Optical 

Fiber Optic Power Meter 

Fiber Optic Spectrum Analyzer.... 
Fiber Optics 



555 

. . 477 , 479-483 
472 

290 

. 145 - 199 , 290 

602 

290 

145-199 

436 

125 

436 

436 

322 

628 

384 

589 

246 

246 

255 

246 

246 

259 

.. 332 , 348-351 

510 

.. 512 - 519 , 535 

322 , 326 

325 , 326 

314 

314 , 352 



18 FUNCTIONAL INDEX 



Functional Index 



Filters 




EMC Screen 




Light 




Mesh 




Floating Measurements 




Frequency Counter, Optical Wavelength 




Frequency Counters 




Function Generators 




Furniture also see Carts 




Carts 




Workstation 





G 

Generators, Signal 



Arbitrary Waveform 440 

Audio 601-604 

CATV 601-603 

Component-Serial, Analog, NTSC, PAL, Digital 601-603 

Data 456,459 

Data Time 456 

Digital Component 601-603 

Digital Composite, NTSC 601-603 

Digital Modulated 226, 227 

Function 

Ghost Canceler Reference 601-603 

Handheld 601-604 

High Definition Sync, Test Signal, Waveform Monitor 599, 601-603 

Insertion 601-603 

IQ Modulated 226, 227 

Microwave Signal 225-245 

MPEG 

Pattern 456,601-603 

Programmable 601-603 

Pulse 440-454 

Pulse/Function 456 

SDH/SONET 336-347 

Sync 601-603 

Television Test Signal 601-603 

Tracking 194 ^ 198 

Word 456 

GPIB Adapters 

GPIB Cables 

Ground Leads, Probe 540-551 



H 

Handheld Products 

Accessories 484-487 

Audio (TV) Analyzer/Generator 601-603 

Digital Audio (TV) Analyzer/Generator 601 

Digital Multimeters 479-483 

Optical Power Meters 326 

Oscilloscopes loi 

PAL/NTSC Signal Generator 601 

Waveform/Vector/Picture/Audio Monitor 597 

High Definition 

Programmable TV Generator 601-603 

Television Oscilloscopes 68, 77, 92 

Television Sync Generator 601-603 

Waveform Monitor 597 

High Resolution Spectrum Analyzer, Optical 314 

High Voltage Probes 533, 553 



1C Clips 

PLCC Packages 535 

SOIC Packages 535 

Indices 

Alphanumeric 4 

Functional i6 

Inserts/Generator goi -603 

Instrument/Probe Reference Chart 498, 499 

Instruments, Reconditioned 618 

Instruments, Stimulus 455, 456 

Instruments, Switching and Scanning 437 

Interface Cables 573 

ISDN Analyzers 424, 427 

ISDN Simulator/Monitor 430 

J 

Jitter Analyzer, SOH/SONET 333, 344 

L 

Laser Optical Sources 355 

Leasing Program 613 

LED Optical Source 355 

Light Filters 539 



FUNCTIONAL INDEX 19 



Functional Index 



Light Measurement 312-330, 352, 355, 357 

Line impedance Stabiiization Network (LiSN) 265 

Literature, Appiication Notes 620 

Locai Area Network (LAN) Adapter 90 

Logic Anaiyzers 

Accessories 134-136, 495-590 

Microprocessor 

Disassembly 

Support 

Logic Scope 

Low Capacitance Probes 620, 521 

Low Impedance Voltage Probes 520, 521 

M 

Mainframes 

Logic Analyzers 

Oscilloscopes 113, 290 

VXl 439 

Measurement Instruments, Systems 436 

Memory Comparison ^25 

Meter Leads 

Meter, Optical Power 322, 326, 355, 357 

Meter, Power 212 

Meter, 212-224 

Microprocessor Support Products 137 

Microwave & RF Instruments 

Accessories 144-199, 495 

Communications Test Sets 266-288 

EMl/RFI Solutions 246-265 

Signal Generators 225-245 

Software 259,262 

Spectrum Analyzers 145-199 

Spectrum Monitor 599 

Mobile Radio Test Sets 266 

Modular Instruments 

Optical Converter/Power Meter 295, 322 

Signal Sources 456 

Modulation Analyzer 147, 176 



.599 



Monitors 

Spectrum 

Stereo Audio ^^4 

Waveform 599 

MPEG Test System 592 

Multimeter, Optical Power 922 

N 

Network Analyzers 200 

New Products 25-48 

O 



Optical also see Opto-Electronic Instruments 


320 


Optical-to-Electrical Converters 

rintiral Pnuupr Meter 


116, 293, 295 

322, 326, 355, 357 


Optical Reference Receivers, SDH/SONET 


297, 299 

322, 355, 357 






upuuai iiawcicimni - 

Opto-Electronic Instruments 

r -aKIa Tocfino Ontiral 


320, 359-365 




Hratiral AHaniiatnr 320, 355, 357 


Optical-to-Electrical Converters 


116, 293, 295 

295 






DniAfor fWlotpr OntirPil 


322, 326 


Oscilloscopes 


495-589 



Battery Operated ^^4 

Carts 582-585 

Communications Signal Analyzer 290 

Delay Line ^^0 

Digital 113,290 

Heads 116,295 

Multi-Channel Unit 120 

Digital/Optical Communications 58, 290 

Digital Phosphor 58, 95 

Digital Sampling 113,290 

Digital Storage 49-122, 290 

DMM 



104 



20 



FUNCTIONAL INDEX 



Fu nctional Index 



Handheld 

Logic Analyzer Based 

Mainframes for Modular Plug-Ins 

Modular 

Optical-to-Electrical Converters 

Plug-Ins 

Portable 

Probes 

Rackmount see Individual Product Options 

Rackmount Kits 

Sampling 

Accessories 

Service 

Software 

Storage 

Digital 

Variable Persistence 

Telecommunications 

Television 

Training 

Travel Accessories 



104, 597, 598 

125 

113,290 

113,290 

290, 293, 295 

116,295 

.60, 68, 77, 92, 95, 101, 104 
495 

588 

88, 113, 290 

120 

92-108 

81-87, 109-111 

49-115, 290 

49-115 

68, 113, 290 

68, 290 

68, 77, 92, 95, 101 

617 

586 



P 



Passive Voltage Probes 

Patch Cords 

Pattern Generator 

SDH/SONET 

Performance Analysis Support... 

Photometers 

Picture Monitor, Handheld 

Power Dividers (SMA) 

Power Meter, Optical 

Power Meters, RF 

Power Plug Options 

Power Sensors 

Power Supplies 

Pre-/Post-Certification Software 
Pre-/Post-Certlfication System .. 

Prequalification Software 

Preselector, RF Stepping 

Price List 



523-534 

578 

125 , 348 - 351,456 

348-351 

125 

488 

597 

579 , 580 

. 295 , 322 , 326 , 355 , 357 

212 

619 

222 

469 - 471 , 516 , 518 

262 

262 

262 

264 

633 



Probes 

iX-lOX Switchable 524, 528 

Accessories 542-551, 578, 579 

Active (PET, Bipolar, Bias/Offset) 510-519, 535 

Adapters 579 

Articulated Arms/Probing Stations 538 

Attenuators 580-581 

Current 564-574 

Current Amplifiers 568 

DC Coupled Current Probe 566 

Differential 555-561 

Discontinued Instrument Probe Replacement Guide 500-505 

Discontinued Probe Replacement Guide 508, 509 

PET 512-519,535 

PET Voltage Probe Tutorial 510 

Ploating Measurements 552, 562 

Ground Leads 540-551, 578 

High Prequency 512-519, 535 

High Voltage 552, 562 

Instrument/Probe Reference Chart 498, 499 

Isolation Systems 562, 563 

Low Capacitance 520, 521 

Low Impedance 520 

Low Loading 510, 520 

Microprocessor/Bus Probe Adapter 137 

Obsolete Probe to Replacement Probe Cross Reference 508, 509 

Optical-to-Electrical Converters 116, 295 

Oscilloscope to Probe Cross Reference 498 

Passive Voltage 523-534 

Probe Tutorial 496 

Replacement Guide for Discontinued Probes 508 

Replacement Parts 540, 541 

RP 222 

Small Geometry Probes 533, 534 

SMT Device Probe/Interconnects 535 

Specification Chart 506, 507 

Voltage 

Active 510-519,535 

High Voltage 553, 554 

Low Impedance 520 

Passive 523-534 

Specification Chart 506, 507 

Word Recognizer/Trigger 575 



FUNCTIONAL INDEX 21 



Functional Index 



Protocol Testers 388-435 

Protocol Tester Software 388-435 

Pulse Generators 456 

R 

Radiometers 488 

Rackmount Products 

Bit Error Rate Testers 348-351 

Carts 582-585 

Communication Test Sets 266-288 

Kits 588 

Oscilloscopes 49-121, 290 

RF Meters 212 

SDH/SONET Test Set 341-345 

Signal Sources 225, 440-452 

Spectrum Analyzer 145-199 

Radio Communication Test Sets 266-288 

Radio Test Sets, Mobile 266-288 

Receivers, SDH/SONET 116, 295, 297, 299 

Reconditioned Instruments: TekSelecr'^ 618 

Reference Information 

Arbitrary Generators 440 

Attenuator Selection Guide 510 

Cart Selection Guide 582 

Communication Test Sets 266 

EMI/RFI Solutions 246 

Instrument/Probe Chart 498 

Logic Analyzer 125 

Microprocessor Support Selection Guide 137 

Microwave and RF 146-149 

Network Analyzers 200 

Obsolete Probes to Replacement Probes 508, 509 

Oscilloscopes 50-61 

Oscilloscope Selection Guide 62-67 

Oscilloscope to Probe Cross Reference 498 

Power Meters 212 

Power Plug Options 619 

Probe Selection/Tutorial 496 

RF Meters 212 

Self-Study Programs 617 

Signal Generator Selection Guides 226 

Spectrum Analyzer Selection Guide 146-149 

Telecommunication Products see Access Network Products 352 



Voltage Probe Reference Chart 617 

VXI Systems 436 

Remote Control 125 

Rental Companies 613, 638 

Rental Program 613 

Repair, Upgrade, Warranty Services 615, 616 

Representatives 621 -632 

RF Insertion Units 222 

RF Meters 212-224 

RF Probes 222 

RF Products 

Cable TV Spectrum Analyzer 384 

Demodulator 608 

Power Meters 212-224 

Probes 222 

Radio Communication Test Sets 266 

Signal Generators 225-245, 438 

Signal Level Meter 382 

Spectrum Monitor 314, 599 



Spectrum, Optical 
Sweep Receiver . . 
Sweep Transmitter 



RS-232-C Cables 578 

S 

Sales & Service Offices 621 

Sampling 

Accessories 120 

Delay Line 120 

Heads 116,295 

Mainframe H3 

Multi-Channel Unit 120 

OptIcal-to-Electrical Head 116, 293, 295 

Oscilloscopes 88, 113, 290 

Scanners, VXI 437 

SDH Portable Test Set 341-347 

SDH/PDH and Jitter/Wander Test Set 338 

SDH/SONET Analyzer 336-342 

SDH/SONET Reference Receivers 297, 299 

SDH/SONET Test Sets 338-347 



Selection Guides see Reference Information 



22 FUNCTIONAL INDEX 



Functional Index 



Semiconductor Testers 490-494 

Curve Tracers 491-493 

Socket Adapters 494 

Serial Digital 

Video Interface 601-603 

Waveform Monitor 597-598 

Service Information 

Calibration 615 

Options 616 

Warranty, Repair and Upgrade 616 

Service Oscilloscopes 92-108 

Service Training/Seminars 617 

Signal Analyzers 113, 290 

Signal Generators (also see Generators) 225 

Digital Modulated 227 

IQ Modulated 227 

RF Sources 236 

Signal Level Meter 382 

Signal Sources 

Arbitrary Generators 440 

Digital Signal 244 

RF 240,242 

Television 601-603 

Vector 227 

VXI 436 

SMA 

Adapters 546-548 

Attenuators 518, 580 

Cables 578 

SMD Probe/Interconnects 535 

Software 

Arbitrary Generators 441 

Debug Tools 125 

EMI Testing 259, 262 

EMI Prequalification 260, 262 

Meters 109-111 

Oscilloscope 81-87, 109-111 

Protocol Tester Software 388-432 

Signal Acquisition and Analysis 441 

Spectrum Analyzer 122, 259, 262 

VM700T Remote Graphics 594 

VM700T Backup and Remote Control 594 



VM700T Remote Control 

VXI 

Waveform Generation 

S0NET/DS3/DS1 Test Set 

SONET Portable Test Set 

Source Code Support 

Spectrum Analyzers 

Accessories 

Battery Powered 

Cable TV Analyzer 

Full-Range Microwave 

Modulation Analyzer 

Optical-to-Electrical Converter 

Optical Spectrum 

PC-Based Systems 

Plug-In, Optical 

Portable 

Preselector 

Probes, RF 

Software 

Tracking Generator 

State Analyzer 

Stimulus Systems/Instruments 

Sweep System, Cable TV 

Switching and Scanning Instruments 

Systems 

Avionics 

Digitizers 

General Information 

Mainframes 

Measurement Instruments 

Sources 

Switching/Scanning 



594 

436 

441 

336 

341-347 

125 

144-199, 265, 495 

188 

384 

145-199 

176 

116, 295, 320 

314, 320 

246 

320 

160, 174, 176, 188, 194, 384 

264 

222 

259, 262 

199 

125 

438, 456 

384 

437 

436-439 

437 

439 

436 

439 

438 

438 

437 



Technical Support 614-617 

Telecommunications Test see Access Network Products 352 

Television Test Equipment 590-609 

Accessories 495-589 

Audio Analyzers 604 

Audio Measurement Set 594 

Cable TV Spectrum Analyzer 384 



FUNCTIONAL INDEX 23 



Functional Index 



Demodulators 

Generators 

Audio Signal 

Handheld Test Signal 

Insertion 

MPEG Test System 

Serial Digital Video Interface — 
Test Signal Generators/Inserters . . 

Spectrum Analyzers 

Spectrum Monitor 

Stereo Audio Monitors 

Vectorscopes 

Video Measurement Sets 

Waveform Monitors 

Terms and Methods of Sale 

Test Leads 

Test & Measurement Software 

Arbitrary Generators 

Debug Tools 

EMI Prequalification 

EMI Testing 

Meters 

Oscilloscope 

Protocol Tester Software 

Signal Acquisition and Analysis 

Spectrum Analyzer 

VM700T Backup and Remote Control 

VM700T Remote Graphics 

VM700T Remote Remote Control . . . 
Waveform Generation 

Test Sets 

SDH/PDH 

SONET/DS3/DS1 

Test Systems 

Avionics 

Digital 

Digitizers 

Mainframes 

Measurement Instruments 

Sources 

Switching/Scanning 



604 


Time Domain Reflectometry (TOR) Systems 


366 


.601 -603 
.602, 603 




359-365 






.602, 603 




113,290 




520-522 




. .592 




125 


603 




199 


.601-603 


Tracking uenerator lor opeciruiii HUdiy^cid 


617 


384 




586 


599 






604 


V 




599 




599 


594 




594 


.597, 599 



612 

578 

441 

125 

262 

259, 262 

109 

.81-87, 109-111 

388 

441 

259, 262 

594 

594 

594 

441 

338 

336 

436 

437 

438 

439 

439 

438 

438 

437 



VITS/ITS Inserter 

Voltage/Probe Reference Chart 506 , 507 

436-439 

Avionics 

Digital 

Digitizers 

Mainframes 

Measurement Instruments 

Software 

Sources 

Switching/Scanning 

W 

Wander Analyzer, SDH/SONET ^58 

Warranty, Repair and Upgrade Services 615 , 616 

Waveform Analyzers 

Waveform Digitizers 

Waveform Monitors 

Wavelength Meter, Optical 516 

Wireless Communication Test Sets 266 

Word Recognizer/Trigger Probes 575 

Workstation, Carts 



24 



FUNCTIONAL INDEX 



Tektronix' Measurement Solutions 



With a comprehensive family of more 
than 1,400 test and measurement prod- 
ucts, Tektronix is at the forefront of 
enabling new technologies and is often 
first to market with innovative products 
that support evolving standards. 

Tektronix is poised to meet the 
increasing demands for quality testing 
imposed by the digital information age. 
As technologies converge, adapting to 
change forces companies to solve 



today’s problems even as they evolve 
in anticipation of future changes. 
Tektronix products can help ease 
the transition and uncertainty. 

By leveraging its expertise in comput- 
ers, communications and video, 
Tektronix is in a unique position to 
lead the way as these markets converge 
and demand for new tools and meas- 
urements emerges. 



Tektronix continues to earn its leader- 
ship position by focusing on solving 
customer problems. Because of 
Tektronix’ acknowledged expertise and 
proven success in video, customers can 
count on Tektronix to help them meet 
new demands. In addition, Tektronix’ 
experience in signal testing - from 
source to destination - will enable cus- 
tomers to grow and prosper wherever 
the information highway leads. 



TEST AND MEASUREMENT PRODUCTS 



Electronic Design Engineering/ 
Performance Products 

► Oscilloscopes 

► Logic Analyzers 

► Spectrum Analyzers 

► Curve Tracers 

► Signal Sources 

► VXI Instrumentation 



Value Electronic Design 
Engineering 

► Oscilloscopes 

► Power Supplies 

► Digital Multimeters 

► Function Generators 

► Counters 



Communications Test 

► OTDRs/TDRs 

► ISDN Testers 

► SDH/SONET 
Testers/Analyzers 

► Optical-to-Electrical 
Converters 

► SDH/SONET Reference 
Receivers 

► Bit Error Rate Tester 

► Protocol Testers 



TV Test 

► Video Measurement Test 
Sets 

► MPEG Testers 

► Waveform, Audio and 
Digital Monitors 

► Vectorscopes 

► Generators 

► Inserters 

► Audio Measurement 
Testers 

► Demodulators 



Tektronix Products for every signal type 




www.tektronix.com/Measurement/ 



NEW PRODUCTS 25 






www.tektronix.com 

Detailed information on Test and measurement products at your fingertips 



Piwlans Su|»poii Silnwp 



Tektronix 



I I" 



The World Wide Web has become an invalu- 
able source of up-to-date information about 
Tektronix products. You can also find online 
support press releases and application notes 
on the latest research. 




INa Stnw iMluoy. nd R*phe«n^ 

Pot Ukntaii. DM Stefan C«Wag 

Haw my iKd Tkklmiitf Ktnort miiii^pi uD iM 

Cagml Qaadsaa m Comnaflb 



Contact Tektronix at: 
www.tektronix.com/ Measurement/ 
Feedback/welcome_new.html 




Find the latest Y2K information at: 
www.tektronix.com/y2k 



C.M.Ct Ut 
E>«cg««. P'rfitt 

IXiOai 

tm««w 



1H. .tjtarrwnt. and mfunnaboo provHted by Td««ronta cm 
« hw ancJ «cv prWMJ. by T«hbw. 

concaminQ Y««r »#•# ol tte prTMluct.. ara 



to tbs Ymt iita Informatton and Uaadlnaa* 

(P.l. ia»-IEI).l»ii»l»tMbta<otiiji‘ primary, oHicUl 

■rttaa 




rfi y ?nCB rroar.m 



Ottl.T MipjfictumT i P 'stfuai 



T«l.*r«ni» f 

predvxn .oil «oppon .Yrtamt. boH> mumal and axtama 
r«ady foe the year 2000 To c»«v out that comnMtment, . 
have o»tab«fhod a comp»ehoesi.e propiam. dnoetod 
thceugh a Teat 2000 Bcogtam Othce. afid o«ec«een by 
•enio' manaoetnent 



26 




Find material that ¥vlll 
make you more productive 
with the instrument 
you already own. 




Welcome to our site, 
bringing you the 
latest news, interactive 
demos, and application 
information, or register 
for a seminar. 




Where to Buy 

Contact your nearest 
sales office from one 
of our woridvride 
locations. 




NEW PRODUCTS 27 



www.tektronix.coni/Measureneiit/ 











IW714/720 






The Tektronix 
TLA 714/720 
Logic Analyzers, 
including Microprocessor 
Support and our Embedded 
Systems Tools Partners 



Leading-edge Designs 

Taking on Today's Digital 
Designers 

Can you answer yes to even one of these 
design challenges? Accelerated technological 
changes. Extreme time-to-market pressures. 
Measurement and analysis design challenges 
for next-generation microprocessors like 
RAMBUS. Elusive problems ranging from 
analog signals to HLL source code. 

If so, whether you are a hardware developer, 
a software developer or a hardware/software 
integrator, you will find our newest logic 
analyzers - the TLA 714 and TLA 720 - answer 
the need for your entire digital design team. 



Tektronix new logic analyzers offer an industry- 
leading combination of acquisition speed, 
channel width and memory depth, all of which 
are essential for supporting next-generation 
microprocessor designs. Now offering up to 
16M, the TLA 714/720 have the deepest 
memory configuration in the industry plus an 
innovative hardware-assisted display system 
to simplify the management of such a large 
memory. They are also the only logic analyzers 
that provide simultaneous 200 MHz state and 
2 GS/s timing on the same probe. 

And when you match our industry-leading 
product performance with our Embedded 
Systems Tools Partners Program and our Third- 
Party Microprocessor Support, hardware and 
software embedded systems designers now have 
the flexibility to choose the best tools to speed 
their development and debug efforts. 



For further information see page 125, or on 
the web at www.tektronix.com/Measurement/ 
logic_analyzers/ 



28 



NEW PRODUCTS 



www.tektronix.com/Measurement/logic_analyiers/ 




Logic Analyzers 
TLA 

The TLA 700 Series addresses the needs of the entire 
digital design team. HW developers, HW/SW integra- 
tors and embedded SW developers will all find the 
TLA 700 provides solutions for those elusive problems 
ranging from analog signals to HLL source code that 
threaten their product development schedules. 




TLA 720 - Both the portable TLA 714 and the 
henchtop TLA 720 combine impressive performance 
and a modern graphical user interface to simplify 
debugging complex system problems and enable 
engineering teams to meet or exceed their develop- 
ment schedules. 




From right: The 34-CH, 68-CH, 102-CH, and 136-CH 
Logic Analyzer modules; available with depths up 
to 16 Mbits per channel with your choice of probes. 
A TLA 720 henchtop mainframe can hold up to five 
modules for a total of 680 channels. 



A New Family 
OF Instruments 

The TLA 700 Series is a 
new family of instru- 
ments developed speclfl- 
caliy to address the fast- 
changing needs of 
today's digital design 
engineers. These prod- 
ucts bring new technolo- 
gy to bear on the time 
and design pressures 
faced by digital system 
designers. 



New Products 





MagniVu™ “ A 64-Bit data bus and its clock signal 
acquired with MagniVu technology, showing that 
the bus takes about 3 ns to settle when the value 
changes. Some individual data signals are shown 
also, including the first and last to change. The 
clock signal and the slowest data signal are shown 
as acquired by the DSO. 



Data acquired by all instrument modules is precisely 
time correlated. You can now easily see when signal 
quality causes timing faults. 

For further information see page 125, or on 
the web at www.tektronix.com/Measurement/ 
logic_analyzers/ 



N Eg 



P R O D U CIS 



29 



www.tektronix.com/Measurement/logic_analyzers/ 




Tlie Tektronix 
TDS 694C - 
A Cornerstone for digital 
systems testing-includ- 
ing Rambus, AGP, and 
other high-speed buses. 
Provides 3-GHz 
Bandwidth 
Simultaneously Across 
All Four Channels 
to the Probe Tip. 



New Products 



THE P6249, 4 GHz, 
FET PROBE 

Measures 3.0 V Logic, 
RAMBUS DATA LINES, 
RISETIME on Gigabit 
Ethernet, Fibre Channel, 
IEEE 1394. 

THE P6248, 1.7 GHi, 
DIFFERENTIAL PROBE 

The P6248 enables users 
to make time domain or 
frequency domain 
measurements on high 
bandwidth signals 
commonly found in disk 
drive, digital 1C design 
(RAMBUS), and 
communication 
applications (Gigabit 
Ethernet IEEE 1394 
FlreYTlre and Fibre 
Channel). 



Digital Storage Oscilloscope TDS 694C 




Examine Your Signal 
Activity in Detail 

Tektronix’ TDS 694C digital storage oscillo- 
scope (DSO) provides the highest bandwidth 
and sampling rates available for accurate 
measurement of high-speed digital signals. 
The fom-channel, 3-GHz bandwidth DSO can 
simultaneously sample up to 10 GS/s on all 
channels. With the TDS 694C, digital design 
engineers can connect the powerful DSO to 
their device under test (DUT) and perform 
system characterization, verification and vali- 
dation, as well as high-speed timing and jitter 
measurements. 




P6249. 

For further information see page 512, or on 
the web at www.tektronix.com/Measurement/ 
accessories/ 



The TDS 694C is ideal for characterizing sig- 
nals in microprocessor systems and compo- 
nents such as motherboards, chip sets and 
graphics accelerators. The DSO also offers 
high-performance measurement for communi- 
cations equipment design, including hubs, 
routers, disk arrays and other high-speed data 
transmission equipment. The TDS 694C can 
also he used to record data from single-shot 
events in quantum electronics, including fast 
analog pulses and components. 

The DSO is Java-powered, extending the capa- 
bilities of the basic scope, enhancing the dis- 
play for specific applications and offering a 
continued path for additional future capabili- 
ties of the scope. The available jitter measure- 
ment package is especially useful for automat- 
ically measuring and characterizing jitter in 
leading-edge digital designs. 

► The TDS 694C provides the highest single- 
shot bandwidth and time measurement 
accuracy available on any oscilloscope. 

► With 3 GHz bandwidth and 10 GS/s sam- 
ple rate on each of its four channels simul- 
taneously, the TDS 694C is capable of 
measuring the time difference between sig- 
nals with ±15ps accuracy while displaying 
important signal details such as glitches, 
overshoot, and undershoot. 

For further information see page 77, or on the 
web at www.tektronix.com/Measurement/ 
scopes/ 



30 NEW PRODUCTS 



www.tektronlx.coiB/Measureineiit/ scopes/ 







Engineering 

Rambus 

Integration 

Solving today's leading-edge 
digital design challenges, 
including Rambus and the 
next generation of 
microprocessors, requires 
an entire test and 
measurement solution. 

With this year's 
introduction of three 
cornerstone products, 
the Tektronix 
TDS 694C, the TLA 714/720 
and the DG2040 - today's 
speed-driven engineers can 
swiftly integrate Rambus 
technology into their 
state-of-the-art designs. 



THE Rambus challenge 

Today, Rambus systems are driving state-of- 
the-art digital performance, with a sophisticat- 
ed memory-to-processor architecture and a 
high-speed chip-to-chip interface, called 
Rambus DRAM (RDRAM). Although RDRAMs 
deliver a quantum leap in performance, they 
increase the complexity of the verification, 
debug and characterization of processor-based 
applications. 

The Need For Speed. ..And Accuracy 

Couple the complexity of Rambus with today’s 
rigorous time-to-market schedules and its clear 
how essential it is to choose measurement 
tools that not only deliver repeatable perform- 
ance validation, but do it quickly. The right 
tools can literally save weeks in the design 
of a memory system, simply by revealing 
circuit performance details that elude lesser 
instruments or by making measurement results 
easier to comprehend and analyze. 



The Tektronix Solution 

With this year’s introduction of three new cor- 
nerstone products; the Tektronix TDS 694C, 
the TLA 714/720 and the DG2040, engineers 
now have a complete and robust suite of per- 
formance tools to swiftly— and effectively- 
integrate high-speed digital technologies, such 
as Rambus, into their designs 
From board-level to system-level to code-level, 
Tektronix delivers the most comprehensive, 
performance solution for all of your high- 
speed digital designs needs. 

New! TDS 694C Digital Storage Oscilloscope with 
complementary intelhgent connection devices 
New! TLA 714/720 Logic Analyzer 
New! DG2040 Data Generator 
New! TDSJITl Software 
New! TDSPSMl Software 

For further information see page 77, or on the 
weh at www.tektronix.com/Measurement/ 
scopes/ 



www.tektronix.com/Measurement/scopes/ 



NEW PRODUCTS 31 




DATA GENERATOR 
DG2040 

Our newest offering in the 

DG2000 Series Data Pattern 

Generator Family 

ARBITRARY WAVEFORM 
GENERATOR AWG610 
With 2.6 GS/s and 8 MB 
memory makes the AWG610 
the fastest stimulus ideal for 
digital Read-channel simula- 
tion, 100 hast T and Avionics 
Testing and well-suited for 
the failure analysis of semi- 
conductors and subsystems 
for magnetic and optical 



An Important 
Component in Verifying 
Your System Design 

The DG2040 is a high-speed, dual-channel 
1.1 Gb/s data generator used for serial signal 
simulation. Electronic design engineers can 
use this flexible logic source to supply high- 
speed data or clock stimulus in the design, 
characterization and verification of semicon- 
ductors or digital logic circuits. 

The DG2040 offers Edge Control, a unique fea- 
ture that simulates jitter or wander conditions 
in serial data or clock signals that is likely to 
occur in a real operating environment. The Edge 
Control feature permits the design engineer to 
select all or specific edges in the serial data 
stream or clock to apply jitter. An external mod- 
ulating signal up to 500 MHz provides dynamic 
control while front panel control provides pre- 
cise, static timing shifts up to ±100 psec. 



data storage products R^te 1.1 Gbps; Pattern Depth: 256 K/ch.; 

requiring characterization up Rise & Fall Time (20% to 80%) 150 psecs.; two 
to 800 Mbits per setond. complementary output data channels and one 
complementary clock output. 

32 NEW PRODUCTS 



AWG 6io Addresses the 
Challenging Needs Of the 
Disk Drive Market 

The AWG 610 features high-speed clock rates 
up to 2.6 GS/s, making it the fastest stimulus 
available for Digital read channel simulations. 
Its deep 8-Mbyte output Memory also provides 
higher resolution for complete sector simula- 
tions and affords longer play times. The 
AWG 610 features an easy-to-use application 
focused Graphical User Interface that allows 
engineers to precisely Create, Modify and 
Output standard and custom waveforms. 
Real-world signals, such as precise timing and 
jitter impairments, can be simulated using the 
unique Region Shift capabilities of the AWG. 

Semiconductor applications require high-perform- 
ance, mixed signal, functional test and device 
characterization capabilities. The AWG 610 out- 
puts analog and serial digital waveforms to meet 
these testing requirements. Although the removal 
of noise is a common goal, using the AWG 610 as 
a noise source is extremely useful for testing 
i mmuni ty to this type of signal impairment. 



w¥vw.tektronlx.coni/Measureiiient/sigiwi_sources/ 






Digital Phosphor Oscilloscope TDS 3000 



Better Tban Analog. 
Better Than Digital. 
And More... 



With Hs compact 
lightweight form factor, the 
TDS 3000 Scries, with its 
optional battery pack, can 
bring the power of 
DPO anywhere you 
need H to go. 



Mainstream Design 

Last year Tektronix’ introduced a new genera- 
tion of award winning oscilloscopes to the 
marketplace, the Digital Phosphor Oscilloscope 
(DPO). This year, Tektronix is proud to intro- 
duce the newest member of the DPO family, 
the TDS 3000 Series. With its advanced con- 
nection, capture and measurement capabilities, 
the TDS 3000 Series offers design, manufac- 
turing test and repair engineers, a new level of 
performance — all in one portable, affordable 
and state-of-the-art instrument. 

You Have To See It To Believe It 

Combining the best features of analog and dig- 
ital oscilloscopes, the TDS 3000 Series oscillo- 
scopes can display, store and analyze three 
dimensions of signal information in real time. 
Ideal for analyzing complex signals, the TDS 
3000 Series includes: 



h 2-channel, 4-channel models 

► 100 MHz, 300 MHz, 500 MHz bandwidths 
P Real-time intensity-graded color display 

for analyzing waveform anomalies that can 
be elusive with traditional Digital Storage 
. Oscilloscopes 

b Modular add-on functionality for applica- 
tion specific measurements 

► Built-in floppy disk drive 
b QuickMenu interface 

For further information see page 95, or on the 
web at www.tektronix.com/Measurement/ 
scopes/ 

New in January 2000 : 

b Telecommunications Mask Testing 
App Module 

b lOBaseT LAN Communication Module 



NEW PRODUCTS 33 



New Products 






A Tektronix Best-Seller 
...Just Got Better 

If your bench, 
production line or training 
lab needs include an 
affordable, yet high 
performance oscilloscope, 
a TDS 200 Series 
oscilloscope from 
Tektronix is the 
educated choice. 



Mainstream Design 

Introducing a new and improved TDS 224 
Series Digital Storage Oscilloscope from 
Tektronix. Offering unbeatable combination of 
performance, reliability and versatility, the 
TDS 200 Series offers breakthrough digital 
and real-time advantages — at an affordable 
price — and now, the TDS 224 offers the 
power and flexibility of four channels. 



The TDS 200 Series - An Ideal 
Choice For: 

► Design/debug 

► Service and repair 

► Manufacturing test and quality control 

► Education and training 

The Four Channel Advantage 

An ideal solution for today’s exacting debug 
challenges, no other digital oscilloscope offers 
as much bandwidth and sample rate for the 
price. In fact, by sampling at 10 and 16 times 
their bandwidth on all channels, the TDS 200 
Series oscilloscopes provide accurate real- 
time acquisition up to their full bandwidth. 



For further information see page 101, or on 
the weh at www.tektronix.com/Measurement/ 
scopes/ 



34 



NEW PRODUCTS 



www.tektronix.coin/Measurenieiit/Kopes/ 



RF Design and EMI/EMC Testing 



3026 Real-time Spectrum 
Analyzer 

The new 3026 real-time Spectrum Analyzer 
provides design engineers and manufacturing 
final test evaluators of communications equip- 
ment an affordable product that can be used 



to quickly evaluate a design or the final prod- 
uct for transient (BURST) phenomena that 
otherwise might not show up until it is in the 
end user’s hands. 

For further information see page 153, or on 
the web at www.tektronix.com/Measurement/ 
commtest/ 



RF Design and 

EMI/EMC 

Testing 

Tektronix offers 
a variety of toois for 
RF design and for 
EMI/EMC testing. 




ESI EMI Test Receiver 

The ESI family of EMI test receivers combines 
the flexibility and speed of spectrum analyzers 
with the large dynamic range required for EMI 
measurements in conformance with standards. 

The ESI family comprises three models with 
different upper fi'equency limits: 

► ESI7: 20 Hz to 7 GHz 

► ESI26: 20 Hz to 26.5 GHz 

► ESI40: 20 Hz to 40 GHz 

All three models are characterized by: 

► High sensitivity 

► Excellent large-signal immunity 

► Low measurement uncertainty 

► High measurement speed 

For further information see page 247, or on 
the weh at www.tektronix.com/Measurement/ 
commtest/ 




www.tektrofiix.coai/Measureiaeiit/ 



ZVR Network Analyzer 

A seven-model family that sets new perform- 
ance benchmarks. Each model delivers the 
highest dynamic range in its class, and executes 
measurements far more quickly than existing 
tools. In addition, the ZVR/ZVG family simpli- 
fies complex tasks such as intermodulation dis- 
tortion (IMD) tests and calibration procedures. 

For further information see page 201, or on 
the web at www.tektronix.com/Measurement/ 
commtest/ 




New Products 



RF Design and 

EMI/EMC 

Testing 



See o«r 
speckrvRi 
sl^t geilerMeH, 

oiiaiyiers 

an4 imre. 



new products 35 







Mobile Networks 




Tektromx 



EdI flbiaot* fluwy jable Ofitiore fitaph 



^firdcm Heb GwWeoy Daply Seh<) 




PRE3 



Fvcnii liitiph 



Event 18666 (Time reference: 60 seconds) 



•-IslTtSl 



-51 

•71 

•814' 

•91 






New Product^ 



Recently, market pressure is building for 
enhanced data delivery and telephony servic- 
es, global roaming, internet access, e-mail, 
and even video. 



► Existing 2G systems are experiencing great 
competitive pressure for assured Quality of 
Service (QoS) 

► Interim technologies (2.5G) such as HSCSD 
and GPRS will emerge, offering enhanced 
data delivery over existing 2G networks 

► New standards and formats are emerging 
and contending to become the worldwide 
3G standard 

What improvements are needed? 

Fundamentally, wireless users want even 

more services from their mobile sets: 

► Much-enhanced data delivery and 
telephony services 

► Global roaming 

► Internet access, e-mail, and even video and 
more in the future. 



mi 



36 NEW PRODUCTS 



The Tektronix strategy is self-explanatory: 
when a new wireless test requirement arises, a 
proper toolset should be there in advance to 
meet the need. 

But for now, wireless network operators and 
equipment manufacturers need test solutions 
that will address two pressing issues: 1.) keep- 
ing pace with burgeoning 2G demand for 
capacity and innovative products, and 2.) 
ensuring superior quality of service (QoS) as 
wireless industry competition grows even 
more intense. 

Tektronix offers a wide range of 2G test equip- 
ment, from integrated RF air interface analysis 
tools to signaling protocol analyzers. 

TEKTRONIX 2G WIRELESS SOLUTION SET: 

► The new 3066 Real-Time Spectrum 
Analyzer 

► The M366plus GSM Quality Analyzer 

► Tektronix’ K1205 Protocol Analyzer 



www.tektronix.com/Measurement/ 






Mobile 

Networks 



3086 Real-Time 
Spectrum Analyzer 

The 3086 has been designed to serve the wire- 
less industry throughout its transition to 3G. 
The 3086 is more than just the first spectrum 
analyzer on the market to offer a chip rate suf- 
ficient for the full range of W-CDMA-based 
technologies. 

Its real-time acquisition makes it possible-even 
easy-for engineers to examine burst events and 
transient phenomena. The 3086 captures a full 
30 MHz band of signal activity simultaneously, 
easily encompassing the full width of a 
W-CDMA channel. 

The 3086 is a DC-to-3 GHz instrument 
whose wideband input mode delivers a 
20.48 MChip/sec symbol rate. The Tektronix 
3086 Real-Time Spectrum Analyzer has all the 
features needed to pave the way for 2.5G, 
transitional, and 3G technologies, and it is 
available now. 



Unique features of the 3086 include the ability 
to analyze signals in the following domains: 

► Time vs. frequency 

► Time vs. amplitude and phase 

► Time vs. code power 

Additional displays allow examination of: 

► Constellation and vector 

► Error vector magnitude vs symbol 

► EVM on individual code channels 

► Demodulation to bit level of all types of 
modulation 

For further information see page 150, or on 
the web at www.tektronix.com/Measurement/ 
commtest/ 



New Products 




www.tektronix.com/Measurement/commtest/ 



NEW PRODUCTS 



37 





Mobile 

Networks 

K129T GPRS 
CMAIILITIES 

Portable Multi-protocel 
Tester for Monitoring 
Simulatiott, 
i;mi|lation and 
Conformance Tests 



Packet Simulation, 
Emulation and 
Monitoring for the 
GPRS Gb and G1 
Interfaces 

Packet Simulation and 
Monitoring for the 
GPRS Gr and Gs 
; . Interfaces 




Mol 
Networks 

A host of new 
Dkideband^COIIIA 
(W-CDMA) capabilities 
to the SMIQ platform, 
already established as a 
leading measurement 
tool for 3rd Generation 
wireless technologies. 



The SMIQ-B is an inte- 
grated confipirable 
soIntlQii that addresses 
the flesign and manvfic- 
turing test of wirelc^ 
components, mobile 
stations, aniTbase 
stations. 



38 NEW 



PRO DU 



■i 




K1297 GPRS 

Multi-protocol Tester 

An example of the 2.5G trend is the design 
and deployment of a new GPRS (General 
Packet Radio System) overlay network. GPRS 
uses the existing circuit switched GSM net- 
work infrastructure for voice traffic and adds a 
new packet switched network consisting of 
GPRS support nodes for data traffic. The 
result is a much-improved data rate of up to 
160 kb/sec (vs. the 9.6 kb/sec rate of standard 
GSM networks). It's no wonder that wireless 
customers are anxious to gain the benefit of 
GPRS enhancements! 

The K1297 Protocol analyzer with new GPRS 
software allows monitoring at all new net- 
work interfaces (such as support nodes) in 
GPRS systems as well as the simulation of 
GPRS network elements. It is ideal for the 
monitoring of GPRS protocols and services, 
and verifying inter-operability of GPRS with 
adjacent networks. 



Capabilities: 

► Portable Multi-protocol tester for monitor- 
ing, simulation, emulation and confor- 
mance tests 

► Packet simulation, emulation and monitor- 
ing for the GPRS Gb and G1 interfaces 

For further information see page 401, or on 
the web at www.tektronix.com/Measurement/ 
commtest/ 

SMIQ-B RF Signal 
Generator 

The SMIQ-B offers a broad range of selectable 
modulation types, encompassing all of today's 
prevalent standards as well as W-CDMA. 

It also provides for user-designed custom 
modulation formats, a valuable feature in the 
emerging 3G realm where modulation stan- 
dards are still far from stable. 

For further information see page 227, or on 
the web at wvirw.tektronix.com/Measurement/ 
commtest/ 




TS 



www.tektronix.com/Measurement/ 







► 

► 




Easy expandable and automatic recognition 
of system configuration 
Graphical and flexible call and traffic con- 
figuration 

Powerful analysis including protocol 
decoding 

Ideal product for load testing, automatic 
service testing, billing verification and 
roaming tests 

For further information see page 269, or 
on the web at www.tektronix.com/ 
Measurement/commtest/ 



► 

► 

► 

► 



MCGS Mobile Call 
Generation System 

The Mobile Call Generation System (MCGS), 
and air interface and signaling test system for 
GSM cellular networks. 



► 



Air interface test system for GSM900, 
DCS 1800, PCS 1900 and dual band net- 
works 

Generating end-to-end traffic 
Stimulates GSM mobile networks 
and tests all the components 
(MSG, BSC, BTS) 






AMIQ Modulation 
Generator 

The AMIQ is a powerful dual-channel arbitrary 
waveform generator with 14-bit vertical resolu- 
tion and a 100 MHz sample clock rate. Designers 
who must evaluate and debug new W-CDMA 
components and test engineers who must quali- 
fy those components in production will need its 
16.384 Mchips/sec rate. Instruments limited to 
lesser chip rates will not meet the requirements 
of the emerging high-capacity digitally modulat- 
ed wireless technologies. 

The AMIQ, paired with an SMIQ vector signal 
generator, produces a comprehensive and 
future-proof solution for all of the prevailing 
digital modulation formats: TDMA, CDMA, 



IS-95, and W-CDMA. The SMIQ vector signal 
generator family is renowned for its signal quali- 
ty and includes four models ranging from econ- 
omy to high performance. The SMIQ's front- 
panel controls can be used to operate the AMIQ, 
eliminating the need for a stand alone PC. 

► 14-bit resolution 

► 4,000,000 samples memory depth 

► 100 MHz sample rate 

► Integrated hard disk and floppy disk drive 

► Optional BER measurement 

For further information see page 233, or on 
the web at www.tektronix.com/Measurement/ 
commtest/ 




Mobile 

Networks 

Mobile Call 
Generation System 
The new MCGS simulates 
end-to-end traffic at the 
radio interface for the 
GSM900, DCS1800, 

PCS 1900 and dual-band 
(900/1800) networks. As 
the most complete air 
interface/signaling test- 
ing device available, the 
system provides equip- 
ment manufacturers and 
cellular operators with a 
means for software veri- 
fication, load, roaming 
and system integration. 



New Products 



Mobile 

Networks 

The AMIQ Modulation 
Generator, a high-speed 
l/Q modulation 
generator which 
supplements the SMIQ 
vector signal generator 
family. The AMIQ 
provides Wideband- 
CDMA (W-CDMA) and 
other signal formats for 
use in testing RF 
wireless components. 



www.tektronix.com/Measuremeiit/ 



NEW PRODUCTS 39 





Mobile 

Networks 

The M366plus Release 
5.0 GSM Quality 
Analyzer measures 
voice, data, and fax qual- 
ity in GSM networks. 
The M366plus Release 
5.0 analyzer includes a 
basestation and one or 
more mobile stations 
that generate end-to-end 
connections between 
PSTN, GSM, DCS and PCS 
networks. By testing 
specific parameters in 
the voice channel, the 
analyzer can identify 
trouble spots and pro- 
vide objective measure- 
ments of voice quality. 




M366 System 

► Quality of service, O&M and network opti- 
mization for GSM 900, DCS 1800, dual 
band and for PCS 1900 

► Voice quality measurements: clipping, 
echo delay, echo loss, loudness rating, 
impulse noise, psophometric noise 

► Cellular data and fax quality test 

► SMS verification 

► Determination of subscriber satisfaction 
level 

► Automatic generation 
of calls from a cellular phone 
to a fixed or cellular phone 

► Simultaneous 
measurements on up to 
4 different networks 

► Run-time display of results 
on digital maps 

► Post-processing of data 
obtained during measurement 
campaigns 



The M366 system includes two units that gen- 
erate automatic voice and data calls between 
each other. The M366plus/GSM basestation is 
a fixed unit that can be connected to as many 
as eight PSTN interfaces. The unit is able to 
simultaneously generate voice calls to the 
mobile unit, and serve as an answering device 
to receive calls from mobile units. 

For further information see page 267, or on 
the web at www.tektronix.com/Measurement/ 
commtest/ 



New Products 



M OBI IE 
Networks 

The FSIQ series of 
signal analyzers, 
offering fully integrated 
spectrum and 
modulation analysis for 
third-generation (3G) 
wireless technologies, 
particularly 
Wideband-CDMA 
(W-CDMA), and for 
today's leading wireless 






FSIQ Series Spectrum 
Analyzers 

The FSIQ series provides uncompromised 
adjacent channel power ratio (ACPR) measure- 
ments on W-CDMA equipment. 

The FSIQ Series exceptionally low typical 
phase noise and low thermal noise floor deliv- 
ers the dynamic range of 75 dB for measuring 
ACPR. For research and design and compo- 
nent test applications, the increased head- 
room makes it possible to characterize new 2G 
or 3G mobile phone and base station designs 
with greater accuracy and confidence than 
ever before. In manufacturing, the improved 
dynamic range allows narrower guardbands. 



► High-speed synthesizer with 5 ms sweep 
time for FULL SPAN (FSIQ3/7) 

► High display update rate up to 25 sweeps/s 

► Large color display with high resolution 
(24 cm/9.5" TFT) 

► Frequency, time and modulation domain in 
one box analysis 

► 75 dB ACPR (Adjacent Channel Power 
Ratio) in 4.096 MHz integration bandwidth 
for alternate channel 

► Integrated vector signal analyzer for 
W-CDMA 

► Digital demonstration up to 6.4 Msymbol/s 

For further information see page 156, or on 

the web at www.tektronix.com/Measurement/ 

commtest/ 



standards including 
GSM, IS-136, and 
W-CDMA. 



NEW PRODUCTS www.tektronix.com/Measuremcnt/ 




40 




Ki205 Protocol Analyzer 

The K1205 Protocol Analyzer is a low cost, 
lightweight signalling protocol analyzer for 
telecommunication network monitoring. It is 
the ideal tool to quickly and accurately moni- 
tor, decode, and troubleshoot signalling proto- 
cols in wired and mobile networks. 

Capabilities: 

► Network monitoring and analysis of CCS#7, 
GSM900, DCS1800, PCS1900, CDMA, ISDN 
D-channel and V5.x protocols 

► Simultaneous connection of 16 - 

2 Mbits/sec links with 32 time slots 

► Decodes over 150 signalling protocols 
including country and manufacturer- 
specific protocols. 

The VI. 2 software also delivers Calltrace 
capabilities for all telephone user part (TUP) 
protocols and improves Calltrace capabilities 
for ISUP. 

► Portable multi-protocol tester for monitor- 
ing at a variety of interfaces 

► Simultaneous connection of up to 

16 PCM30/PCM24 with up to 32 time slots 

► Automatic recognition of the measuring 
configuration 



► State-of-the-art modular design enables 
easy expansion 

► Simple operation under Windows NT 

► User-friendly help system 

► Large number of country-specific and 
manufacturer-specific protocols 

For further information see page 396, or on 
the web at www.tektronix.com/Measurement/ 
commtest/ 







Mobile 

Networks 

The low-cost and light- 
weight K1205 provides a 
cost-effective solution to 
quickly and accurately 
troubleshoot maintain 
and manage wired and 
mobile networks. 



New Products 



Net-C Monitoring System 

Monitoring systems are designed to measure 
voice, data and fax transmission quality for 
fixed and mobile networks. Essential to pro- 
viding quality service, these systems are used 
by network operators to assess the service and 
to identify problems and malfunctions within 
the network before they affect the customer. 

Containing non-intrusive algorithms 
(INMD/ITU-T P.561), the product can be used 
by network operators to monitor and analyze 



the transmission quality of 2-Mb/s telephone 
systems. It can also be used to detect fraud 
and network misuse, such as call back, blue 
box, refile, CSM roaming fraud and cloning, 
estimated to cost telephone network operators 
up to $4 billion per year, according to indus- 
try experts. 

For further information see page 389, or on 
the web at www.tektronix.com/Measurement/ 
commtest/ 




Mobile 

Networks 

The NET-C monitoring 
system, provides users 
with centralized control 
for assessing quality of 
service (QoS) and detect- 
ing fraud in real-time, 
mobile and fixed 
telecommunications 
networks. 



www.tektronix.com/Measurement/ 



NEW PRODUCTS 41 




Tektronix continues 
to broaden its 
photonics-test product 
portfolio with industry- 
leading solutions that 
address the latest 
requirements. 

Significant increases in 
network capacity 
requirements have 
driven the demand for 
rapid deployment of new 
core network technologies. 
Consequently, test and 
measurement plays a key 
role in enabling the 
development and 
deployment of 
these networks. 



Core Networks 





New Products 



Key Features and 
Benefits of the 
ST2400A 
Option 42 

Receive Error Count 
Transmit Error Insertion 
Transmit and Receive 
Payload Patterns 
Automatic Protection 
Switch (APS) Time 
Measurement 



ST2400A SDH/SONET 

Test Set 

The ST2400A SpH/SONET Test Set verifies the 
end-to-end integrity of 2.488-Gbit/s networks. 
Network operators installing high-speed paeket- 
basetf%e^brl^*:V\d^ niost fi:om the new 

capabjiUfies of the ST24 The ST2400A can 
emuiaterthe diaraGted an SDH or SONET 

nei^brkblenient. the ST240PA is optimized for 
Jesj^^ quality of 2.488 Gbit/s 

STM-IB; (SONET) networks 

trahspgrted.oye^ D\\T)M systenis. 

To mmimize teS time, the Tektronix ST2400A 
/ can be used to eGonomically test all channels of 
ailWDM sysfeni i^ One optical input 

signal is .spht multiple ways, ^ the test per- 

son deploysjt^'set-upw^ the necessary num- 
r^W.of ST2400 As at the^ 

sav 6 time without incurring 
-.do^:fiigh' capital costs of parallel test. This 
approach also kUows: the to allocate finan- 
^ OialTesources \yhefe most needed - at 

the-Teceiver, where’ the data niust be analyzed. 



NEW RECEIVER AND TRANSMITTER CAPABILITIES 

The variable receiver-decision tlrcBsliold 
allows the tester to eiriulate:systehi:i^ _ 
caused by optical amplifiers, and 
ter emulates the entire astern.. The ST2.40QA 
can emulate a leg^. system • 

user to adjust and set te desn^n th^iold iii 
accordance wi^ systein It will 

then produce m '.error •resiSlt &at iBpre 

predicts; the beha\mH: oT©idj|P'S : ^ _ . 

The variable;reGeiver-deGision‘'tIiresh^^^ . . v 

also provide an .easy w^-maccBlorMe-;^^^ . 
measurement of -a y«ry- few "iBi 

This wiU save' us, ers signpcant^^^^^ ^ 

2,488 Gbit^. * . .. -. ’ 4 ? ^ 

New nansmi^r j^uts^'^^ ' r . V 

2.048 MHz md:2:.048:M^^ 

nm jng-sy nrhrnniagfe in.oT ^d SDH- r " ; , 

systenis* The ST24PDA^’Pseudo-R ; /V 

SequeiffiB (PRBS) albws-mnidatian of live^^,-!V \ 
fic transport under ti3st eonditibns* ■ , 

For further informatioii see page 344, hr 

the web at wvw.tektronixxomiMeasmreni^^^ " 

commtest/ ' ■ ^ 



42 NEW 



PRO DUCTS. 



www.tektronix.com/Mea5urement/coiniiit.esf/ 





CTS 850 SDH, PDH, Jitter 
AND Wander Test Set 

The CTS 850 provides the most complete jit- 
ter and wander test solution. With its 300 UI 
jitter-measurement range, the CTS 850 can 
capture the pointer hits and counts useful for 
troubleshooting such time-sensitive services 
as 2-Mbit/s GSM and PBX. It can also measure 
frequency drift rates, enabling users to assess 



the existence and magnitude of timing impair- 
ments in video and GSM services. Available 
with a complete set of masks, the CTS 850 can 
also measure down to 0.1 Hz, with variable 
high-pass cut-off frequency, to fully character- 
ize phase transients. 

For further information see page 338, or on 
the web at www.tektronix.com/Measurement/ 
commtest/ 




Core 

Networks 

CTS 850 analyzes 
2-Mbit/s to 622-Mbit/s 
digital broadband 
networks. 

The as 850 Is the first 
test set in the industry 
to incorporate the ITU-T 
Recommendation 0.172, 
a standard proposed by 
the International 
Telecommunication 
Union for jitter and wan- 
der measuring 
equipment. 



The Q7750 

Optical Network Analyzer 

The Q7750 Optical Network Analyzer. The 
Q7750 was developed for optical transmission 
design engineers and component manufactur- 
ers in the Dense Wavelength Division 
Multiplexing (DWDM) market. 

By providing 600 data points in four seconds, 
the Q7750 Optical Network Analyzer rapidly 
yields optical carrier- frequency measurements 
for optical elements. In addition, the Q7750 
analyzer, with its narrow group delay meas- 
urement range of 25 ns and maximum resolu- 
tion of 0.1 ps, allows engineers to accurately 
measure the overall chromatic dispersion of 
optical components, modules, and systems. 

The Q7750 Optical Network Analyzer quickly 
and accurately characterizes a variety of opti- 
cal communication devices including arrayed 
waveguided gradients, fiber bragg grating fil- 
ters, and dispersion compensators. 

For further information see page 328, or on 
the web at www.tektronix.com/Measurement/ 
commtest/ 




New Products 



Core 

Networks 

The Q7750 provides 
superior amplitude, 
chromatic dispersion, 
and group delay meas- 
urements for testing 
optical communication 
devices. 



www.tektronix.com/IVIeasurement/ 



NEW PRODUCTS 43 




Core 

Networks 

LPB SERIES 

The LPB series 
of tunable laser 
diode sources 
help component 
d^igners and 
manufacturers fully 
characterize optical 
communications systems, 
particularly DWDM. 



New Producti 



Core 

Networks 

D3186/D3286 

The D3186/3286 BERT 
provides designers with 
the ability to evaluate 
and analyze 
high-speed 
communications 
systems, such 
as DWDM and 
SONET/SDH. 



44 N EW' P R O D U 



Tunable Laser Diode Sources 

LPBiioo, LPB1300, LPB1550 

Features and benefits include: 

► Mode-hop free for smooth and accurate 
wavelength tuning 

► High power output for low noise measure- 
ments and real-life signal emulation 

► Wide spectral range to fully characterize 
designs within the wavelength window of 
interest 

► Amplitude modulation and mode-locked 
operation for non-continuous wave test 
requirements 



► Fine tuning for precise wavelength (fre- 
quency) resolution 

► Characterization of fiber optic components 
(splitters, couplers, Bragg grating, etc.) 

► Characterization of optical amplifiers 
(EDFAs, etc.) 

► Testing of optical communication transmis- 
sion systems 

► Emulation of DWDM optical signals 
For further information see page 303, or on 
the web at www.tektronix.com/Measurement/ 
commtest/ 







D3186/D3286 12 Gb/s bit 
] ERROR rate tester (BERT) 

j The D3186/D3286 BERT, a high performance 
bit error rate tester (BERT) excels at character- 

! izing and analyzing high-speed digital 

telecommunications network devices such as 
integrated circuits (ICs) and high-speed opti- 
cal components, as well as dense-wavelength 
division multiplexing (DWDM) and high- 
speed SONET/SDH transmission systems. 
Designers and manufacturers can use the 
D3186/D3286 BERT to evaluate and analyze 
high-speed communications systems, includ- 
ing high-speed logic devices, multiplexers, 
repeaters, and digital transmission systems up 
to a frequency range of 12 Gb/s. For instance, 
the tester can he used to verify the integrity of 
a 10 Gb/s transmission system by enabling the 
user to simulate and detect errors in 
SONET/SDH traffic. 

Compatible with optical transmission stan- 
dards 0C3/STM-1 (155.52 Mb/s) to 
OC192/STM-64 (9.95 Gb/s), the D3186/D3286 
BERT operates at frequencies ranging from 
150 Mb/s to 12 Gb/s. The product can also 



generate SDH and SONET frames that allow 
users to evaluate information under condi- 
tions virtually identical to real data. The 
cross-point position of the data waveform can 
easily be varied with a simple twist of a knob, 
located on the front of the tester, to enable 
users to compensate for waveform output and 
mark the ratio evaluation of high-speed logic 
IC and laser diodes. Finally, the D3186/D3286 
BERT provides multi-channel outputs and 
8 MB of memory to generate WORD, PRBS, 
and mixed patterns. 

For further information see page 332, or on 
the web at www.tektronix.com/Measurement/ 
commtest/ 




www.tektronix.coin/Measuremeiit/ commtesV 




Modular Laser-Source 
Mainframe LPM5000 

Features and beneiits include: 

► Modular form factor provides flexibility for 
multi-wavelength applications 

► Large display and easy controls for adjust- 
ing the parameters of up to eight modules 

► Mainframe form factor allows convenient 
rack mounting (19 in. rack) 



► IEEE std-488.2 and RS-232-C compliant for 
automated test environments 

► Internal and external amplitude modula- 
tion operation for noncontinuous wave test 
requirements 

For further information see page 306, or 
on the web at www.tektronix.coni/ 
Measurement/commtest/ 




Core 

Networks 

LPM SERIES 

The LPM series of 
modular laser sources 
enable component 
designers and 
manufacturers to fully 
characterize optical 
communications systems, 
such as DWDM. 






Q7606 Chirp Test Instrument 

The Q7606 Chirp Test Instrument quickly 
calculates the alpha chirp value in under 45 
seconds for optical communication signals 
transmitting 10 Gbps or less. 

At these transmission speeds, the system can 
experience intersymbol interference because 
the optical signal's wavelength briefly shifts. 
This brief wavelength shift enlarges the width 
of optical signals in the time domain, creating 
what is referred to as chirp. 

Until now, engineers could not quickly meas- 
ure chirp with such excellent resolution and 
repeatability performance. The Q7606 chirp 
instrument decreases testing time from 20 
minutes to under 45 seconds and provides 
the highest resolution for chirp measurements 
at <20 MHz. See page 312. 



I 




www.tektroiiix.coai/MeasureBeiit/conntest/ 



Q8163 Optical Polarization 
Scrambler 

The Q8163 Optical Polarization Scrambler 
and Q82232 Optical Sensor - that, when used 
with the Q8221 Optical Power Meter and 
Q82203 Interface Plug-in, provide a complete 
system for measuring Polarization Dependent 
Loss (PDL) and associated PDL wavelength- 
dependency characteristics in optical devices. 
This system performs one PDL measurement 
per second with an accuracy of ±0.01 dB. 

The Q8163 optical scrambler provides fast 
polarization variances of up to 500 Poincare 
Sphere rotations per second. This enables 
users to quickly generate random optical 
polarization states, thus significantly reducing 
PDL measurement time. The Q8163 scrambler 
also provides an insertion loss of < 3 dB. 

See page 318. 




New Products 



Core 

Networks 

The Q7606 Chirp Test 
Instrument, provides 
engineers with a fast and 
reliable method for 
measuring chirp in high- 
speed DWDM and 
SDH/SONET systems. 

The Q8163 Optical 
Polarization Scrambler 
and Q82232 Optical 
Sensor enable PDL 
measurements when 
combined with the 
Q8221 Optical Power 
Meter and Q82203 
Interface Plug-in. 



NEW PRODUCTS 



45 




Access Networks 

TELEPHONE PRODUCTS 
II your job is to analyze and 
troubleshoot the access 
network for analog or 
digital services/the 
Tektronix TelScout(S/ TS200 
is built for you. Designed 
specifically for telephone 
access network 
applications, including 
xDSL, ISDN, and POTS. 

TheTeiScoutTS200 applies 
the newest technology to 
provide both ease-of-use 
and telephony performance 
that cannot be found 
in any other access 
network analyzer. 






A helpful xDSL poster 
explaining and mapping the 
various services and a 
comprehensive telephone 
access network 
measurements book are 
available on the web at 
www.Tektronix.com 
To read or print these 
documents, go to the 
website and follow the 
instructions provided- 
or contact your local 
account manager 
for paper copies. 



Handheld Access Network Analyzer 



optical and- 

networks. The 

prim^^^diis of oiiTiinew access network prod- 
ucts is oh enabling mass' de^ of digital 

services. Our products 

to assist custoffl'ers.&M^^ and 

reducing cost^lor the$e and 

highly competitive: servi^^^ 

TELSC0UT™:^TS2bd 

The TS200 a handheld access 
lyzer for usejn clearing and testing outside ;■- 
plant fox^5d)Sl; and The 1 ? 

TelScout® TS2Q0 alshdfe 
phone systeih'(F’OTS) and timedomam reflec- 
toineter (TDR) measuremenhGapabihtie^^ 
meet the cornmuiii'Gations iudustry!s need to 
del i ver analog arid digital semises "supportih 
appl icatidns,sudh^as high^^ internet access 

and video conferencing. / ' ' . > 



As telecomniunications customers increasingly 
demand high-speed digital services over their 
existing outside plant, the measurement and 
qualification of the access network have 
become critical. 

Features and .benefits include: 

► TestWizard^^^ - true: one-button testing 
Full function TDR with automatic multiple 
. event marking 

► Flexible, upgradeable platform 

' ► Complete ondine help and tutorials 

► Rugged design - suiviveS 2 m drop 

► Automatic hazardohs voltage s^^ warning 

► Extra large, high-contrast, backlit 

For fiirthef information see page 373, or on 
the at www.tektrpnix:comyMeasurement/ 
coramtesl/ 




46 NEW PRODUCTS 



www.tektronix.com/Measurement/comintest/ 



Access Networks 



CATV PRODUCTS 
The DMA120 Series of 
portable field tools now 
provides comprehensive 
in-service performance ver- 
ification measurements for 
both 64- and 256-QAM 
transmissions. Network 
operators activating digital 
transmission of video or 
downstream highspeed 
digital services on the 
RF Broadband System will 
use the DMA120 Series. 




New Products 



DMA120 Series 

► Automated in-service measurements of sig- 
nal level, adjacent channel levels, modula- 
tion error ratio (MER), estimated noise mar- 
gin, error vector magnitude (EVM), and BER 
before - and estimated BER after - forward 
error correction (EEC). These measurements 
allow operators to determine acceptable 
transmission quality quickly and easily, 
without removing channels from service. 

► At-a-glance troubleshooting. The constellation 
display mode provides a graphic view of view 
of phase and amplitude distortion caused by 
transmission impairments, without removing 
the channel from service. The spectrum dis- 
play mode allows direct viewing of channel 
flatness and symmetry, and sidebands. The 
equalizer tap coefficients, which iudicate 
linear impairments such as unflatness. 



► Portable and battery-operated. Weighing just 
2.1 kg (4.6 lbs.), the DMA120 Series is easy 
to carry up a pole or into difficult-to-reach 
locations. The battery is user-changeable. 

► PCMCIA expansion slot. This accommo- 
dates a memory expansion card, which 
enables storage of a large number of meas- 
urement results for later analysis. 

For further information see page 353, or on 
the web at www.tektronix.com/Measurement/ 
commtest/ 



www.tektronix.com/Measurement/comnitest/ 



NEW PRODUCTS 47 




i 



Java PowereiT 
Applications for the 
TDS500D600C/700D 




java 

leered' 



Embeddedlava 
Technology allows 
Tektronix to deliver 
application specific meas- 
urements in a tfmety and 
: cost-effective manner 
while building a library 
of utilities that enables 
the rapid development of 
additional appHcations. 



New Produc 



Oscilloscope Software 



Tek aERB Single Seq lO.OGS/s 






ftijil lOOmV 



Period 

Mean 

StdDev 

Max 

Min 

Pk-Pk 

Population 



19.995ns 

1.5594ps 

20.001ns 

19.990ns 

10.755ps 

2.04k 



Chi I 



-8mV 



Control 



Mode 



Free Run 



Start 



Pause 



Stop 



Reset 

All 



Measure 


Setup 


Histogram 




Profile 


Control 


Period 


Period 


Oft 




Off 


Ready 



Utility 




TDSjm 

TDSJITi 

TDSJITl Performs a suite of jitter measure- 
ment with unprecedented accuracy on single- 
shot waveforms. Jitter information can be 
displayed as statistics, histograms, or profiled. 

TDSPSMi 

TDSPSMl introduces a revolutionary way for 
making timing measurement by providing 
statistics on specific data and clock edges that 
are fully time-correlated. This application also 
performs automated AC timing measurements 
on all parameters in single-shot acquisitions. 




TDSCEMi 

TDSCEMl performs a suite of automated eye 
diagram measurements on SONET/SDH and 
Fibre Channel standards. These measurements 
include eye height, eye width and quality factor. 

TDSCPMl 

TDSCPMl performs automated parametric 
measurement of pulse amplitude, spectral 
power, and pulse symmetry to standard 
requirements. Standards include ANSI 
T1.102, and ITU-T G.703. 



peR Run; I.OOCS/s Average 



SSSmV 



ITU-T G.703: El coax 
Pulse Symmetry 



2.15V 253ns 

101\ 102\ 

95-105% 95-105% 

Passed Passed 



Limits 
Test 

Standard Data Rale Measure 



Log 

esults 



Utility 



TDSPSMl 



TDSCPMl 



www.tektronix.coin/ Measurement/ 









Oscilloscopes 



TDS Tektronix Digitizing Scope - An innovative advanced performance oscillo- 
scope, featuring multi-processor speed and flexibility, advanced acquisition and 
triggering capabilities and a unique 
graphical user interface for intuitive operation. 

TDS 800 Digital Sampling Oscilloscope - The TDS 820 provides design and test 
engineers w^ith up to 8 GHz bandwidth for characterization of repetitive signals. 

The TDS 820 simplifies the use of a sampling oscilloscope without compromising 
features or performance. 

TDS 700/500 Digital Phosphor Oscilloscopes - Digital Phosphor Oscilloscopes dis- 
play, store and analyze complex signals in real-time, using three dimensions of sig- 
nal information: amplitude, time and distribution of amplitude over time. The TDS 
700/500 Series offer a well rounded package of high-fidelity acquisition, advanced 
triggering, automatic measurements and 

communication signal analysis. TDS 700/500 are the most powerful debug tools for 
electronic design applications. 

TDS 600 Digital Storage Oscilloscopes - The TDS 600 Series provides design engi- 
neers the best tool for characterizing their digital designs. They offer the highest 
performance levels of real-time acquisition and a powerful set of triggering and 
measurement functions. 

TDS 400 Digital Storage Oscilloscopes - For professionals who demand high preci- 
sion and fidelity from their measurements, the TDS 400 combines excellent per- 
formance and a broad feature set, all at affordable prices. 

TDS 3000 Digital Phosphor Oscilloscopes - The TDS 3000 Series are the newest 
Tektronix Digital Phosphor Oscilloscopes. They were specifically developed for 
mainstream design applications with their unmatched combination of real-time per- 
formance, triggering, and automatic measurements all in a small, light and battery 
operated package. With a color display, floppy drive, FFT analysis, and advanced 
triggering available, the TDS 3000 delivers advanced 
capabilities and performance. 

TDS 200 Digital Storage Oscilloscopes - The world’s most popular oscilloscope, the 
TDS 200 Series real-time Oscilloscopes are for engineers and technicians who need 
a compact, easy to use, low cost oscilloscope that will improve productivity and 
measurement quality. There is no better combination of performance, reliability, 
and affordability. The controls will be familiar to analog oscilloscope users both in 
function and format. Automatic measurements, stored waveforms, and other digital 
functions are controlled by on-screen menus in any of ten user-selectable languages. 

THS 700 Digital Storage Handheld Oscilloscopes - The award winning THS 700 
Series now includes: 200 MHz version - the highest performance handheld 
scope/DMM in the market. Power version - tlie first handheld scope to include 
automatic power measurements, statistics, and harmonics measurements. All four 
models in the new TekScope THS 700 Series feature Isolated Channels at full band- 
width with real-time sampling technology. A true RMS digital multimeter is a stan- 
dard feature in the rugged, battery operated handheld package. 

11800/CSA Sequential Sampling Oscilloscopes - The 11801C/CSA 803C series of 
oscilloscopes provide comprehensive measurement capabilities from DC to 50 GHz. 
The modular design of these oscilloscopes allows you to tailor the performance of 
your scope to meet specific application needs. You can select between a wide range 
of plug-in sampling heads that provide various different levels of bandwidth and 
noise performance. 

ORDER ONLINE 

Selected products will be available to order from our web site. For availability of 
this service see our web site at www.tektronix.com/Measurement/ebusiness 



Contents 

Scope Reference 50 

TDS: Selection Guide 62 

TDS 794D/784D/754D/724D/ 

580D/540D/520D 68 

TDS 500D/700D Options and 

Accessories 68 

TDS 654C/680C/684C/694C .... 77 

TDSJITl 81 

TDSCEMl 82 

TDSCPMl 83 

TDSPSMl 84 

TDSDDMl 85 

TDSPWRl 86 

TDSPRTl 87 

TDS 820 88 

AD007 90 

TDS 430A/460A/420A 92 

TDS 3012/14/32/34/52/54 95 

TDS 224 (new) /2 10/220 101 

THS 730A/720A/710A/720P. ... 104 

WaveStar™ SW 109 

11801C 113 

Sampling Heads: 

SD 14/20/22/24 

/26/32/42/44/51 116 

TLS 216 122 

Logic Analyzers 125 

CSA 803C 290 

DL-11 Delay Line 120 

SIU800 Static Isolation Unit 120 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPE 



REFERENCE 49 



Oscilloscopes 

OSCILLOSCOPE REFERENCE 






From the highest performance to the 
most cost-effective solution, Tektronix 
offers a broad range of test and meas- 
urement instrumentation. Tektronix 
oscilloscopes provide the best connec- 
tion to your device-under-test, the most 
accurate signal acquisitions, the 
sharpest waveform displays, and the 
most comprehensive on-board wave- 
form measurements available. 

It takes a broad range of oscilloscope 
products to satisfy the spectrum of 
measurement applications throughout 
the world today, and Tektronix delivers 
the product line breadth sought by 
customers worldwide. 

Following Tektronix’ tradition of bring- 
ing innovative products to the market 
with the introduction of tlie TDS 3000, 
Tektronix now has three families of 
Digital Phosphor Oscilloscopes including 
the TDS 500D and TDS 700D. Designed 
to keep pace with current and evolving 
needs in advanced electronic design and 
debug. DPOs deliver a new level of 
insight that must be seen to be believed. 
DPOs capture, store, display, and ana- 
lyze, in real-time, three dimensions of 
signal information: amplitude, time and 
distribution of amplitude over time. 




50 



OSCILLOSCOPE REFERENCE 



www.tektronix.com/Mea$urement/scope$/ 




Oscilloscopes 

OSCILLOSCOPE REFERENCE 



General Trends in 
Oscilloscope Development 

Today you will find more and more 
special purpose oscilloscopes, such as 
the TDS 700D with their communica- 
tions options, TDS 3000 with its video 
capability, CSA 803C and 11801C with 
bandwidth to 50 GHz and color graded 
display for thorough analysis of high- 
speed communication channels and 
standards testing. 

Our TDS oscilloscopes include powerful 
digital signal processing engines which 
can give you simultaneous time and fre- 
quency domain displays with fast updates. 

Our scopes are constantly getting easier 
to use. We’ve reversed the trend toward 
more buttons and menus. Oiu* new mod- 
els achieve a balance between perform- 
ance and ease of use. We’ve done our 
homework, tested our ideas and greatly 
improved access to important new fea- 
tures without making the basic functions 
hard to find. Volts/division, time/divi- 
sion and trigger level have dedicated 
knobs so you can just grab and turn. 

Measurement, trigger modes, hard copy 
setups and acquisition control lie with- 
in easy reach behind a graphic user 
interface (GUI). Information-packed dis- 
plays are made easy to read with a 
high-resolution color monitor. 



Tektronix Digital Phosphor 
Oscilloscopes, Digital 
Storage Oscilloscopes and 
Communication Signal 
Analyzers 

These products include many innova- 
tive features designed to improve pro- 
ductivity and reduce operating costs. 
Tektronix oscilloscopes represent the 
best combination of performance fea- 
tures, human factors and price on the 
market today. 

► Digital Phosphor Oscilloscopes go 
beyond analog real-time (ART) and 
digital storage oscilloscopes (DSO) 
by incorporating an information- 
rich, real-time display, that surpass- 
es any analog or digital scope’s capa- 
bilities. This new instrument deliv- 
ers a new level of insight that makes 
dealing with complex signals 
straightforward, without loosing the 
full spectrum of digital acquisition, 
storage and analysis capabilities that 
engineers have come to expect in 
their oscilloscope solutions. 

► Digital Phosphor Oscilloscopes 
make it possible to see, store and 
analyze complex signals, such as 
serial data streams that are seen in 
the telecommunications, data com- 
munications and computer/comput- 
er peripheral industries. 



► Digital Phosphor Oscilloscopes pro- 
vide three full dimensions of signal 
information-amplitude, time and 
distribution of amplitude over time, 
in real-time. 

► Application specific measurements 
based on Java technology provide 
advanced analysis of acquired 
data, giving the user measurement 
results in familiar terms, specific 
to their industry. 

► The TDS 700D DPO and CSA com- 
munication analyzers give an accu- 
rate assessment of noise, jitter and 
compliance to ITU and ANSI stan- 
dards. Up to 50 GHz bandwidth with 
2.0 ps RMS jitter (1.3 ps typically) is 
available in the CSA 803C. 

► The High Bandwidth (50 GHz) 11801C 
offers the highest timing resolution 
and measurement repeatability. While 
the TDS 800 combines the sequential 
equivalent-time sampling technology 
of the 11 80 1C with the mid-range TDS 
platform for DC-8 GHz bandwidth in a 
portable monohthic instrument. 

► Using oversampling technology, DSOs 
offer single-event waveform capture to 
their full bandwidth. TDS 694C pro- 
vides the highest accuracy delta time 
measurements at ±15 ps. 

► The TDS 3000 DPO has specialized 
display, triggering and measure- 
ment capabilities for working with 
video signals. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPE reference 51 



Oscilloscopes 

OSCILLOSCOPE REFERENCE 




Better than analog. 




Better than digital. 




And more... 



Digital Phosphor 
Oscilloscopes 

Digital Phosphor Oscilloscopes display, 
store and analyze complex signals in 
real-time, using three dimensions of sig- 
nal information: amplitude, time and 
distribution of amplitude over time. 

DPO goes beyond analog real-time (ART) 
and digital storage oscilloscopes (DSO) 
by incorporating an information-rich, 
real-time display, that surpasses any ana- 
log or digital scope’s capabilities. This 
incredible new instrument delivers a 
new level of insight that makes dealing 
with complex signals straightforward - a 
level of insight engineers must see to 
believe. Of course, all of this is com- 
bined with the full spectrum of digital 



acquisition, storage and analysis capabil- 
ities that engineers have come to expect 
in their oscilloscope solutions. 

Like the actual phosphor on an ART 
display, the DPO captures and remem- 
bers the frequency of events, resulting 
in a three-dimensional array that retains 
information for hundreds of millions of 
samples. Chemical phosphorescence 
creates a gray scale because of the 
decay in its energy over time. Digital 
phosphor replicates this decay in inten- 
sity by digitally controlling the replace- 
ment of data in the three dimensional 
array. As a result, a DPO can display, 
store and analyze three dimensions of 
signal information: amplitude, time and 
the distribution of amplitude over time. 




Disk Drive Signal seen in a TDS 784D 
Digital Phosphor Oscilloscope. 



52 



OSCILLOSCOPE REFERENCE 



www.tektronix.com/Measurement/scopes/ 






Oscilloscopes 

OSCILLOSCOPE REFERENCE 



The DPO model takes a hardware-based 
approach to achieve this remarkable 
performance. Using advanced ASIC 
technology. It accumulates multiple 
images of signal information in a 500 x 
200 array of integers. Each integer rep- 
resents a pixel in the DPO’s display and 
is used to control intensity. As a signal 
is acquired over time, this array is con- 
tinuously updated with image after 
image of the signal. Unlike DSOs that 
decimate or throw away an enormous 
number of samples, the incoming sam- 
ples are acquired at rates comparable to 
an analog scope and are all used to cre- 
ate the image. As a result, engineers are 
finally protected against aliasing 
because of the abundance of samples 
collected and used by DPO. 

Creating this detailed image of a wave- 
form’s activity and intensity in hard- 
ware allows a real-time response simi- 
lar to an ART. The acquisition engine 
continuously samples at the maximum 
rate, triggering and building image after 
image with minimal dead time between 
acquisitions. A new snap.shot of the 
digital phosphor is sent to the display 
every 1/3 0th of a second, creating an 
image that responds to waveform activi- 
ty in real time. Even when the display 
is updated, the digital phosphor contin- 
ues to gather new samples. The parallel 
architecture and hardware-based pro- 



cessing enables the DPO to capture all 
the details and anomalies that occur in 
today’s complex, dynamic signals and 
to display as fast as the human eye can 
assimilate them. 

This real-time processing is what sets 
the DPO apart from post-processing 
modes, such as persistence, found in 
today’s DSOs. The post-processing in a 
DSO is executed in software on the nor- 
mally acquired waveforms, and it 
requires acquisition over a long period 
of time to build up the display, thus 
prohibiting instantaneous feedback. The 
time for creating this display is further 
exaggerated as multiple channels are 
turned on, since they use the same 
microprocessor. Plus during this pro- 
cessing time, the DSO is no longer 
acquiring new information and is 
forced to miss salient details on dynam- 
ic waveforms and important aperiodic 
events, often the very behavior an engi- 
neer is hoping to uncover and examine. 
DSOs consequently are limited to cap- 
turing infrequent snap shots of less 
than 1% of the available signals. 

The benefits of using a DPO in electron- 
ic design, debug and test are dramatic. 
By providing a third dimension of 
information, engineers gain new and 
important insights into the behavior of 
complex signals, enabling them to accu- 





rately interpret signal dynamics, 
including the mode of changes in the 
signal and the frequency of occurrence 
of signal phenomena. Instead of using 
two instruments — an ART to see all the 
nuances on the waveform and a DSO to 
capture, measure and analyze signal 
behavior - they can use one powerful 
tool. This will undoubtedly lead to 
more effective debug and performance 
verification, helping to streamline the 
overall design and maintenance tasks. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPE REFERENCE 53 









Oscilloscopes 

OSCILLOSCOPE REFERENCE 



Digitizing Oscilloscopes 

TDS SERIES 

POWERFUL ACQUISITION 

► Digital Phosphor Oscilloscopes 

► 3 GHz real-time bandwidth 
(TDS 694C) 

► XYZ mode (TDS 500D/700D) 

► Four channels of 10 GS/s (TDS 694C) 

► Record lengths of 8,000,000 points 
(TDS 500D/TDS 700D, Opt. 2M) 

► Up to 8 GHz bandwidth (TDS 820, 
Opt. ID) 

ADVANCED TRIGGERING 

► Glitch triggering (TDS 500D/TDS 
600C/TDS 700D) 

► Exclusive runt triggering (TDS 500D/ 
TDS 600C/TDS 700D/TDS 3000) 

► HDTV video triggering (TDS 500D/ 
TDS 600C/TDS 700D/TDS 3000) 

► Setup and hold time violation 
triggering (TDS 500D/TDS 600C/ 

TDS 700D/TDS 3000) 

► Slew rate triggering (TDS 500D/ 

TDS 600C/TDS 700D/TDS 3000) 

► Communication standard triggering 
(TDS 500D/TDS 700D, Opt. 2C) 

Powerful Processing 

► Application specific measurements 
based on Java technology 

► Histograms and statistical math 

► FFT analysis 

► Manufacturing pass/fail testing 

► On-board mask compliance testing 
(TDS 500D/TDS 700D, Opt. 2C) 

► Jitter measurements 

Tektronix Quality 
AND Reliability 

Tektronix’ oscilloscope quality and relia- 
bility are unmatched. Designs are thor- 
oughly scrutinized and tested to ensure 
compliance with all applicable safety 
and environmental standards. Calibration 
is traceable to national standards and 
conforms to military procedures. Our 
service network is designed to help you 
keep your oscilloscope calibrated and 
working with fast turnaround. 




The TDS 794D with 2 GHz Bandwidth 
enables real time analysis of high fi*equency 
signals. 




Tektronix TDS 500D/700D DPOs are the first 
digital oscilloscopes with XYZ mode. 




The optional Comm Trigger addresses the 
need to acquire a wide variety of AMI. CMl 
and NRZ communication signals. 

(TDS 500D/TDS 700D, Opt. 2C). 




TDS triggering can capture glitches as nar- 
row as 1 ns to help solve prototype circuit 
problems quickly. 





Application specific measurement packages 
enhance the DPOs ease of use. 



Histograms and statistical measurements are 
available in YT mode as well as XYZ mode. 



54 



OSCILLOSCOPE REFERENCE 



www.tektronix.com/Measurement/scopes/ 















Oscilloscopes 

OSCILLOSCOPE REFERENCE 




Hi-Res acquisition mode achieves extremely 
high signal to noise ratios (SNR) on single- 
shot events by oversampling the input signal. 



It " j 




SOOmVV) 



The TDS 694C provides four channels of 
3 GHz, 10 GS/s acquisition to capture events 
with high single-shot resolution. 




The TDS 820 provides 0.4 ps timing resolu- 
tion and channel deskew capability to accu- 
rately measure delays in today’s high-speed 
digital systems. 





TDS exclusive runt triggering helps isolate Logic timing analysis is clearly faster and 

invalid logic levels such as those caused by easier with icon-driven state triggering, 

setup and hold violations. 




Optional Video Trigger combined with DPO 
acquisition allows you to see details in 
video signals. 




FFT analysis provides an extra dimension of 
performance with simultaneous displays in 
the time and frequency domains. 



Automatic on-the-fly limit te.sting makes 
manufacturing pass/fail testing an easy task 
(all TDS 400A. TDS 500D. 600C, 700D and 
800 models). 




On-board mask te.sting capability allows 
comparison of signals to standard masks in 
communication systems (TDS 820/1'DS 500D/ 
TDS 700D, Opt. 2C). 



SELECTING AN OSCILLOSCOPE 

The first step in selecting an oscilloscope 
is to know what you’re expecting to see 
with the scope. In other words, what are 
the typical characteristics of the signals 
you need to capture and view. Are your 
signals of a complex nature? Are your sig- 



nals repetitive or single shot? What is the 
bandwidth and/or rise time of the signals 
or transients you need to captme? On 
what signal characteristics will you need 
to trigger - rimts, pulse widths, slew 
rates, glitches? How many signals do you 
need to display simultaneously? The 



answers to these questions will determine 
the type of scope you need. Which brings 
us to the actual oscilloscope and data 
sheet considerations: Digital Phosphor 
Oscilloscope, DSO. bandwidth, sample 
rate, waveform capture rate, record 
length, triggering and otlier capabilities. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPE REFERENCE 55 






















Oscilloscopes 

OSCILLOSCOPE REFERENCE 



THE "5 TIMES" RULE FOR BANDWIDTH 

An Oscilloscope’s bandwidth specifica- 
tion gives you an idea of the instru- 
ment’s ability to handle high-frequency 
signals. If the bandwidth of your scope 
is inadequate, high fi:equency informa- 
tion will be filtered out and critical tim- 
ing information may be displayed inac- 
curately. It’s important to remember that 
a scope’s bandwidth is derived from 
how well it reproduces a sine wave. If 
you’re dealing with high-speed digital 
electronics, you may never see a sine 
wave. A good rule of thumb for deter- 
mining the bandwidth you need is to 
use the “5 times rule”: to figure out the 
bandwidth of the scope you need, multi- 
ply the highest frequency component of 
the signals you want to examine by five. 
This will typically give you better than 
2% accuracy in your measurements. 

In some applications you may not know 
the bandwidth of the signal of interest, 
but you will know the risetime. The fre- 
quency response of most scopes is 
designed so that a constant allows you 
to relate the bandwidth and risetime of 
the instrument using the equation: 

-3 dB Bandwidth x Risetime = K 

where: -3 dB Bandwidth is in Hertz, 
Risetime is the 10% to 90% risetime in 
seconds and K is a constant that depends 
on the oscilloscope input filter type. 

As a general rule of thumb, when select- 
ing an oscilloscope you can assume that 
the bandwidth to risetime relationship 
is about 0.4. Using this to calculate 
bandwidth will give you a ballpark fig- 
ure that is sufficient for scope selection. 

DPX WAVEFORM IMAGING PROCESSOR 

Tektronix’ DPOs are based on a new par- 
allel processing architecture that inte- 
grates the acquisition and display sys- 
tems. The proprietary DPX waveform 
imaging processor in the TDS 500D/700D 
was designed by Tektronix specifically 
for acquiring and managing the three 
dimensions of waveform information of 
the Digital Phosphor Oscilloscope. To 
ensure maximum throughput, it has 
distributed internal control and works 
independently of the other processors 
in the oscilloscope. 

The DPX waveform imaging processor is 
completely dedicated to the acquisition 
and database management process. It 



includes an acquisition rasterizer and the 
digital phosphor three-dimensional data- 
base array that emulates the behavior of 
chemical phosphorescence to provide a 
real-time intensity-graded display. The 
basic operation of the DPX waveform 
imaging processor is drawing repeated 
images in the digital phosphor, control- 
ling the rate of image decay, and periodi- 
cally sending snap shots of that informa- 
tion to the oscilloscope’s display system. 

SAMPLE RATE 

When considering digitizing oscillo- 
scope characteristics and specifications, 
it’s important to make a clear distinc- 
tion between sample rate and waveform 
capture rate. A digitizing oscilloscope’s 
sample rate is specified in Samples per 
Second and indicates how frequently 
the scope samples the input signal. 

With higher sample rate, the signal is 
sampled more frequently allowing 
greater signal resolution. 

The Importance of Adequate Sample 
Rate - The Nyquist sampling theorem 
states that the signal of interest must be 
sampled at least twice the rate of its 
highest frequency component to accu- 
ratelv reproduce it. While this is true “in 



theory,” sometimes it isn’t enough in 
practice. In reality, today’s high speed 
digital signals should be sampled at least 
5 times the rate of the highest frequency 
component (2.5 times the Nyquist rate) 
to be accurately reconstructed. Real-time 
sampling allows full bandwidth single 
shot acquisition and eliminates the need 
for repetitive sampling techniques. 

TRIGGERING 

Extended triggering capabilities offered in 
most Tektronix oscilloscopes allow you to 
capture complex signals for device char- 
acterization or troubleshooting. They also 
provide more selective trigger control 
than is available with conventional edge 
triggering. In addition, their sophisticated 
user interfaces allow rapid setup of trig- 
ger parameters to increase productivity. 

Tektronix oscilloscopes allow you to 
trigger on pulses defined by amplitude 
(such as runt pulses), qualified by time 
(pulse width, ghtch, slew rate, setup- 
and-hold and time-out), and delineated 
by logic state or pattern (logic triggering). 
Combinations of extended and conven- 
tional triggers also help display video 
and other difficult-to-capture signals. 
Advanced triggering capabilities such as 
these deliver a large degree of flexibility 



SELECTION GUIDE 



Type 



Channels 



Bandwidth 



Q. E c 

5 *'7 "5. 

IQ E 



X 

u 



X J2 

V o 



X 

S 



X X 

o o 



AKKUCA 1 lUlM/ KKUUUL. 1 


Q 


oc 


(/) 


fS 


fS 




fNO 


Device 

CHARAaERIZATION 


TDS 800 






X 


X 








Design 

Debuc/Comm 
Signal Analysis 


TDS 700 


X 








X 


X 




Design 

Characterization 


TDS 6 oo 




X 






X 


X 




Design 

Debug/Comm 
Signal Analysis 


TDS 500 


X 








X 


X 




Personal 
Lab Scope 


TDS 400 








X 




X 


hh 


Design 
& Service 


TDS 3000 


X 


X 




X 




X 




Test 

& Service 


TDS 200 




X 




X 




X 


■ 


Handheld 

Portable 


THS 700 




X 




X 






xHH 


Comm Signal 

Analysis/Device 

Characterization 


11800/CSA 






X 


X 




X 





56 OSCILLOSCOPE REFERENCE 



www.tektronix.com/Measurement/scopes/ 



Oscilloscopes 

OSCILLOSCOPE REFERENCE 



when setting up testing procedures and 
can greatly simplify measurement tasks. 

RECORD LENGTH 

Maximum oscilloscope record lengths 
are available from 1 K points to 8 M 
points. Tektronix oscilloscopes provide 
adjustable record lengths that allow you 
to set the record length you need for a 
particular application - depending on 
the detail you need to see. If you are 
simply monitoring an extremely stable 
sinusoidal signal, for example, a 500 
point record length may be adequate. 

But if you’re tr3dng to find the causes of 
timing anomalies in a complex digital 
data stream, a long record length is more 
appropriate. In addition, long record 
lengths provide the detail you need to 
capture and analyze single-shot events. 

Data Management and 
Connectivity 

DATA MANAGEMENT SOLUTIONS FOR 
OSCILLOSCOPES 

The new WaveStar’^'^ Software for 
Oscilloscopes is a Windows 95/98/NT 
application bringing Tektronix oscillo- 
scope measurement information to your 
PC desktop. WaveStar Software’s famil- 



iar Windows features, such as drag and 
drop, provide the user a quick and sim- 
ple means for inserting important 
instrument information into other 
Microsoft Office or Windows compatible 
applications. WaveStar Software allows 
users to easily capture, analyze and 
record instrument data, as well as pro- 
fessionally create, save and print docu- 
ments. WaveStar Software also enables 
remote access and control of TDS or 
THS oscilloscopes on a PC, without the 
need for programming. 

► Capture measurement waveforms 
and data easily, without the need for 
programming 

► Data log from a single or multiple 
instruments 

► Insert information seamlessly in 
Microsoft Office Applications or 
transfer to other Windows 
Applications, such as Mathcad™ 

► Communicate with TDS, THS, 
CSA/11800 oscilloscopes easily 
through an Instrument Connection 
Wizard 




► Capture, EDIT, SAVE and RESTORE 
instrument settings 

► Print banner function for hardcopy 
of long record lengths 

► Control waveform information 
locally or over the network 

► Step away from your desk and have 
WaveStar software automatically 
capture data changes 

► For Windows 95/98/NT systems 

► Use WSTRO free for 30 days 



Record Length 



Device 

CHARAaERIZATION TDS8OO 

Design 

Debug/Comm 

SignalAnalysis TDS700 
Design 

CHARAaERIZATION TDS6OO 




Design 

Debug/Comm 

SignalAnalysis 

Personal 

Lab Scope 

Design 

& Ser/ice 

Test 

& Ser/ice 




Handheld 

PoR-ABLE THS700 X X 

Comm Signal 
Analysis/Device 

CHARAaERIZATION USOO/CSA X 



Triggering 






s i s 

< < S 



X 



X X X X X X X 



X X X X X X X 



X X X X X X X 



X 



X 



X 



X X 



X 



X 



X 



X 



X 



X X 



XXX X Opt. X 

XX X Opt X 



XXX X Opt 

X X X 

X X X X 

X X X 

X X 



XXX X 



w¥fw.tektronix.com/Measureinent/scopes/ 



OSCILLOSCOPE REFERENCE 57 




Oscilloscopes 

OSCILLOSCOPE REFERENCE 




CONNECTIVITY SOLUTIONS FOR 
OSCILLOSCOPES 

The AD007 GPIB - LAN Adapter 
Instrument to Local Area Network 
(LAN), allows you to control your 
Tektronix TDS oscilloscope from any 
networked PC, check on its status, or 
capture waveforms from your office, 
another site, or from anywhere using 
Tektronix WaveStari^’^ Software for 
Oscilloscopes application software or 
your own software. It also enables your 
TDS oscilloscope to print to a net- 
worked printer. 

The Tektronix AD007 GPIB - LAN 
Adapter lets you take advantage of the 
fact that many of today’s computers are 
connected together through an Ethernet 
lOBaseT LAN. 

Accessories 

PROBES AND ACCESSORIES 

Tektronix continues to dedicate 
research and development resources to 
helping customers find ways to connect 
instrumentation to the changing variety 
of today’s new devices and packages. 
You will find some iimovative new 
probes and connecting schemes that 
quickly and cleanly couple to all kinds 
of devices. 




AD007. 



P6248/P6247/P6246 HIGH SPEED 
DIFFERENTIAL 

The P6248. P6246 and P6247 enable 
users to make time domain or fre- 
quency domain measurements on 
high bandwidth signals commonly 
found in disk drive, digital IC design 
and communication applications. 

The small probe head geometry and 
assorted probe tip accessories allow 
these probes to easily accommodate 
manual probing of surface mount 
devices while maintaining high CMRR. 

The P6248. P6246 and P6247 are ideal 
for design verification of disk drive read 
channel electronics, timing analysis or 
troubleshooting ground bounce prob- 
lems associated with high speed logic. 
They can also be used for pulse shape 
or cross talk compliance testing at high 
speed communication signals. 





58 



OSCILLOSCOPE REFERENCE 



www.tektnmlx.aHii/(liea5ure«eiiV**®P®*/ 



Wo- 






Oscilloscopes 

OSCILLOSCOPE REFERENCE 




P6700. 



P6700 0/E CONVERTERS 

The Tektronix P6700 Series optical-to- 
electrical (O/E) converters change opti- 
cal signals into electrical signals for con- 
venient analysis on Tektronix TDS oscil- 
loscopes equipped with the TEKPROBE® 
interface, or any other oscilloscope when 
used with the 1103 TEKPROBE power 
supply. The P6700 Series O/E converters 
are ideal for optical source characteriza- 
tion in the development, manufacture or 
service of optical communication sys- 
tems and devices. 




AFTDS, ATM75. 

AFTDS DIFFERENTIAL SIGNAL 
ADAPTERS 

The AFTDS Differential Signal 
Adapter and the AMT75 75 Adapter 
provide an effective means for 50 
terminated instruments to connect to 
and analyze differential and high 
speed electrical communication sig- 
nals as well as video signals. 

Both adapters are rugged and have the 
TEKPROBE interface which provides 
convenient autoscaling of waveforms 
on Tektronix TDS Series oscilloscopes. 
Also the low VSWR (Return Loss) per- 
formance minimizes measurement 
errors commonly associated with inter- 
facing with complex electrical signals. 

Ideal for use in pulse shape compliance 
testing of high speed electrical commu- 
nication signals. 




P5210. 



DIFFERENTIAL SIGNAL ACQUISITION 
SOLUTIONS 

Four products are available for acquir- 
ing differential signals. The ADA400A 
1 MHz Differential Preamplifier allows 
single-ended oscilloscope measurements 
of very low signal levels (<10 pV) that 
are not ground referenced. The P5200, 
P5205, P5210 Differential Prohes meas- 
ure differential voltages up to 5,600 V 
and have bandwidths up to 100 MHz. 
The new P5210 Differential Probe meas- 
ures differential voltages up to 5,600 V. 
With a bandwidth of 50 MHz, the P5210 
probe easily measures those fast dV/dt 
transitions in switching power devices. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPE REFERENCE 



59 






Oscilloscopes 

TDS Series 




Features - Benefits 



Digital Phosphor Oscilloscopes 
Advanced Applications Packages 
60 MHz to 8 GHz Bandwidth 
100 MS/s to 10 GS/s Sample Rates 
2 and 4 Input Channels 
Advanced Logic Pattern and State 
Triggering 

Runt and Glitch Triggering 
HDTV Video Triggering 
High-resolution Color Display 
Record Lengths to 8 M Points 
8- to 13-Bit Vertical Resolution 

Tektronix TriStar"* DSP for Fast 
Waveform Processing and Live 
Measurement Updates 
DSP Math Including FFT, Integration 
and Differentiation 
Communication Signal Analysis 
Including Mask Testing, Mask 
Autoset and SDH/SONET and Fibre 
Channel Optical Reference Receivers 

Automatic Measurements 



Applications 



Research and Development 
Electromechanical Design 
Telecom Design and R&D 
Biophysical, Biomedical Research 
Power Supply Design 
Component Development and 
Characterization 
Sen/ice and Repair 



Pass/Fail Testing 

Easy Documentation with Saving of 
Image Files to Floppy Disk or 
Hardcopies Directly to Printer 

Full GPIB Programmability 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1 - 503 - 627 - 1916 , 
inside the U.S. call: 
1 - 800 - 426 - 2200 . 



TDS Oscilloscopes 

The TDS is a family of innovative oscilloscopes 
featuring multi-processor speed and flexibility, 
advanced acquisition and triggering capabilities 
and a unique graphical user interface for intuitive 
operation. 

With the TDS, Tektronix introduced a new and 
innovative generation of digitizing oscilloscopes 
designed to keep pace with ciurent and evolving 
needs across the electronics industry. 



To address the complexity of the signals that the 
era of convergence brings, Tektronix’ Digital 
Phosphor Oscilloscopes display, store and analyze 
complex signals in real-time, using three dimen- 
sions of signal information: amplitude, time and 
distribution of amplitude of over time. These 
TDS’s go beyond analog real-time (ART) and digi- 
tal storage oscilloscopes (DSO) by incorporating 
an information-rich, real-time display, that sur- 
passes any analog or digital scope’s capabilities. 



60 OSCILLOSCOPE REFERENCE 



www.tektronix.com/Measurement/scopes/ 






The TDS 700D Digital Phosphor Oscilloscopes. 



TDS 3000 Series Digital Phosphor 
Oscilloscopes. 



Composite video signal. 



TDS combines the performance needed 
with the ease of use demanded by cus- 
tomers in digital design; research and 
development; electromechanical design; 
power supply design; biophysical/bio- 
medical high-speed component devel- 
opment and characterization; and 
telecommunications design and auto- 
mated test. 

The TDS offers significant advantages 
over other oscilloscopes in four major 
areas: 

HIGH-FIDELITY SIGNAL ACQUISITION 

TDS offers sample rates ranging from 
100 MS/s to 10 GS/s and bandwidths 
from 60 MHz to 8 GHz. TDS couples 
this performance with wide dynamic 
range, vertical resolution up to 13-Bits, 
fast overdrive recovery and 1 mV/div 
sensitivity. You’ll find a model that pre- 
cisely fits your needs. 

POWERFUL AND FLEXIBLE TRIGGERING 

TDS 3000, 500, 600 and 700 models 
feature very innovative and accessible 
logic triggering features that can isolate 
glitches, runts and timing problems 
quickly and reliably. Video triggering 
for NTSC, PAL, SECAM and custom 
video standards makes the TDS 3000 an 
excellent choice for video and display 



in all TDS Scopes to permit more meas- 
urement flexibility, instant response to 
commands and live waveform math 
including FFT and waveform pass/fail 
testing in the TDS 400, 500, 600, 700 
and 800. Displays may be sent directly 
to a printer or plotter or exported as 
EPS (Encapsulated Postscript) or PCX 
(Microsoft Windows) files for use with 
common graphics and word processing 
software. The DPX™ waveform imaging 
processor makes the TDS 500D/700D 
the highest performance DPO’s by pro- 
viding the fastest waveform capture rate 
a deepest digital phosphor. 

AFFORDABLE PERFORMANCE THAT IS 
EASY TO USE 

A graphical user interface (GUI) makes 
operation intuitive. A familiar front- 
panel layout puts dedicated knobs for 
vertical, horizontal and trigger controls 
right where you expect to see them. 

This layout makes it easy for casual 
users to operate the basic oscilloscope 
features. Explanatory icons, pop-up 
menus, on line help and the VGA-quali- 
ty display quickly guide users to even 
the most powerful measurement fea- 
tures. A color VGA display is available 
with the TDS 3000, 600 and 700. 



64 QAM Modulation with histograms. 

system design. Specialized HDTV trig- 
gering is available on the TDS 3000, 
500, 600 and 700. 6 GHz trigger band- 
width in the TDS 800 and very low jitter 
make it ideal for high-speed component 
characterization and for telecommuni- 
cations manufacturing, installation and 
maintenance. Four channels of 3 GHz 
real-time acquisition makes the 
TDS 694C a necessity for high-speed 
bus design applications. 

MULTIPROCESSOR ARCHITECTURE 

Our TriStar™ Digital Signal Processor 
complements a multi-processor design 




www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPE REFERENCE 61 








Oscilloscopes 

TDS SERIES 



Selection Guide: 


TDS 520D 


TDS 540D 


TDS 580D 


TDS 724D 


TDS 754D 


TDS 784D 


TDS 794D 




DPO 


DPO 


DPO 


DPO 


DPO 


DPO 


DPO 




Sienal Acquisition System 












1 rut 


1 CMi 


Bandwidth 


500 MHz 
2+2 


500 MHz 
4 


1 GHz 
4 


500 MHz 
2+2 


500 MHz 
4 


1 CjMZ 
4 


4 


Sample Rate: 1 ch. 

2ch. 
3 4 ch 


2GS/S 
1 GS/s 


2 GS/s 
2 GS/s 
IGS/S 


4 GS/s 
2 GS/s 
IGS/S 


2 GS/s 
1 GS/s 


2 GS/s 
2 GS/s 
1 GS/s 


4 GS/s 
2 GS/s 
1 GS/s 


4 GS/s 
2 GS/s 
1 GS/s 


Record Length: Std. 

Opt 


50 K pts. 
4 M pts.*^ 


50 K pts. 
8 M pts.*^ 


50 K pts. 
8 M pls.*3 


50 K pts. 
4 M pts, *2 


50 K pts. 
8 M pts.*» 


50 K pts. 
8 M pts.*^ 


50 K pts. 
8 M pts.« 


Vert. Resolution: Normal 

w/ Averaging 
w/ Hi Res 


8 Bits 
11 Bits 
>13 Bits 


8 Bits 
11 Bits 
>13 Bits 


8 Bits 
11 Bits 
>13 Bits 


8 Bits 
11 Bits 
>13 Bits 


8 Bits 
11 Bits 
>13 Bits 


8 Bits 
11 Bits 
>13 Bits 


8 Bits 
11 Bits 
^13 Bits 




1 mV- 10 V 


1 mV-10 V 


1 mV - lOV 


1 mV-lOV 


1 mV-lOV 


1 mV-10 V 


lOmV-1 V(50a) 




±1% 


±1% 


±1% 


±m 


±1% 


±1% 


±1% 




300 V Cat II 


300 V Cat 11 


300 V Cat II 


300 V Cat II 


300 V Cat 11 


300 V Cat II 


5Vrms(50£2)»" 




+5 div 


±5 div 


±5 div 


±5 div 


±5 div 


±5 div 


±5 div 




±25 ns 


±25 ns 


±25 ns 


±25 ns 


±25ns 


±25 ns 


±25 ns 


D\A/ 1 imif 


20 250 MHz 


20, 250 MHz 


20. 250 MHz 


20, 250 MHz 


20, 250 MHz 


20. 250 MHz 


Full BW only 


Time Base: Range 

Accuracy 


500 ps - 
10 s/div 
25 ppm 


500 ps - 
10 s^iv 
25 ppm 


200 ps - 
10 s/div 
25 ppm 


500 ps - 
10 s/div 
25PP«P 


500 ps - 
10 s/div 
25 ppm 


200 ps- 
10 s/div 
25 ppm 


200 ps - 
10 s/div 
25 ppm 


Delta Time Measurement 


±75.5 ps 
@ 2 GS/s 


±75.5 ps 
@2CS/s 


±38 ps 
@ 4 GS/s 


±75.5 ps 
@ 2 GS/s 


±75.5 ps 
@2 GS/s 


±38 ps 
@ 4 GS/s 


±38 ps 
@ 4 GS/s 


nptprtinn 


1 ns 


1 ns 


1 ns 


1 ns 


1 ns 


1 ns 


1 ns 


rcCI\ L/dvvilUII 

FastFrame™’” Timestamp 
Std.: (372) 50-point frames 
Hnt "jM' 50-ooint frames 


50 to 

50,000 points 


50 to 

50,000 points 


50 to 

50,000 points 


50 to 

50,000 points 


50 to 

50,000 points 


50 to 

50,000 points 


50 to 

50,000 points 


Waveform Capture Rate 

r<;nn nnint uu;i\/pfnrm^/spc^ 


100,000 


200,000 


200,000 


100,000 


200,000 


200,000 


200,000 


(3UU UUIIH WQVCIUI lilJ/ jvv/ 

Display Sample Density 


50 million 


100 million 


100 million 


50 million 


100 million 


100 million 


100 million 




■ ■ ■■■& 

Xncicsoi* 


8 ps 


Bps 


7PS 


8_P5 


8 ps 


m 


7ps 


jiuci 

Trigger Conditioning 


- 

HF, LF, 

Noise Reject 


HF, LF, 
Noise Reject 


HF. LF. 
Noise Reject 


HF. LF, 
Noise Reject 


HF. LF. 
Noise Reject 


HF, LF. 
Noise Reject 


HF. LF. 
Noise Reject 


Types: Edge 

Pattern/State 
Setup & Hold 
Pulse Width 
Glitch 
Runt Pulse 
Slew Rate 
Time Out 
Comm 
External 
Video*® 


Std. 

4 inputs 
Std. 
Std. 

1 ns 
Std. 
Std. 
Std. 
Opt. 
Std. 
Opt 


Std. 

4 inputs 
Std. 
Std. 

1 ns 
Std. 
Std. 
Std. 
Opt. 
Std. 
Opt. 


Std. 

4 inputs 
Std. 
Std. 

1 ns 
Std. 
Std. 
Std. 
OpL 
Std. 
OpL 


Std. 

4 inputs 
Std. 
Std. 

1 ns 
Std. 
Std. 
Std. 
Opt. 
Std. 
Opt 


Std. 

4 inputs 
Std. 
Std. 

1 ns 
Std. 
Std. 
Std. 
Opt 
Std. 
Opt 


Std. 

4 inputs 
Std. 
Std. 

1 ns 
Std. 
Std. 
Std. 
Opt 
Std. 
Opt. 


Std. 

4 inputs 
Std. 
Std. 

1 ns 
Std. 
Std. 
Std. 
Opt 
Std. 


Modes: Delay by Time/Event 


r.?!!.. 

std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 



62 



OSCILLOSCOPE REFERENCE 



www.tektronix.com/Measurement/scopes/ 



Oscilloscopes 

TDS SERIES 

Selection Guide: 



Si^al Processing 


TDS 520D 


TDS 540D 


TDS 580D 


TDS 724D 


TDS 754D 


TDS 784D 


TDS 794D 


Auto. Measurements 


29 


29 


29 


29 


_ 29 


29 


29 


Math 




+,-,x,-^,inv 


+,-,x,+,inv 


+,-,x,-^,inv 


+,-,x,^,inv 


+,-,x,-5-,inv 


+,-,x,-i-,inv 


Envelope 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Average 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Interpolation*^ 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


FFT, Int, Diff. 


Opt. 


Opt. 


Opt. 


Std. 


Std. 


Std. 


Std. 


Limit Test 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


General 


Display Monitor 


Mono 


Mono 


Mono 


Color 


Color 


Color 


Color 


Inf. Persist, Vectors, 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Ools,YT,XYZ*« 
















Data Ports: VGA Out 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


GPIB 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


RS232 


0pt*8 


0pL*8 


Opt*« 


5td.*« 


Std.*« 


Std.*8 


Std.»» 


Centronics 


Opt 


opt 


opt 


Std. 


Std. 


Std. 


Std. 


Hardcopy/export Formats*® 


Std. 


std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Disk Drive (3.5 in.) 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Online Help 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 




Standard Probes 


2 ea. 


4 ea 


None 


2 ea. 


4 ea. 


None 


None 




P6139A 


P6139A 




P6139A 


P6I39A 








500 MHz, lOX 


500 MHz, lOX 




500 MHz, lOX 


500 MHz,10X 








Passive 


Passive 




Passive 


Passive 







Certain restrictions on range apply based on 
other instrument settings. Consult data sheets 
for details. 

'^^XYZ display mode not available on the TDS 
520D and TDS 724D. 

Derate at 20 dB/decade above 1 MHz. 

Assumes measurement of a 2 ns Hide pulse. 
See individual product specification for com- 
plete formula. 

Typical. 

Option XL is mandator}' for all TDS 400 Series. 
*^^TDS 2MM proiides four additional automatic 
measurements and FFT analysis. 



*•'' TDS 400A triggered and untriggered roll. 

TDS 3000 and TDS 200 untriggered roll only. 




IDS SELEaiON GUIDE FOOTNOTES 

With Option ID: Bandwidth = 8 GHz. Vertical 
Sensitivity' = 1 mV- lOOmV/div. Max Input = 
±3V, no pre-trigger. 

Optional record length on TDS 520D/724D is: 
Opt. IM: 250K pts (1-CH). 13UK pts per channel 
(2-CH): Opt. 2M: 4M pts (1-CH). 2M pts (2-CH). 
Optional record length 
TDS 580D/754D/784D/794D: Opt IM: 

500K pts (1-CH). 250K pts per channel 
(2-CH). 130K pts (3-. 4-CH). Opt 2M: 8M pts 
(1-CH). 4M pts (2-CH). 2M pts (3-. 4-CH). 
Maximum number of 50 point frames is 372 
(1489 with Opt. 2M installed). Frame lengths 
50 -50.000 points. 



TDS 3000: NTSC, PAL: TDS 200: Line. Field: 
TDS 400A: .VTSC PAL. SECAM: TDS 
500D/600C/700D: NTSC. PAL. SECAM. HDTV 
FlexFormaf'*. 

Selectable sin(x)/x, linear. TDS 3000. TDS 200: 
sin(x)/x only. 

Talk mode only, for hardcopy purposes. 
Supported formats: TIFF. BMP. PCX. RLE. 
Interleaf (IMG). PostScript. Laserfet. Epson. 
Thinkjet. DeskJet. DPU411/412. 

TDS 3000/400A/500D/600C/700D also support 
Spreadsheet. MathCad'^ waveform formats. 
TDS 200 support: Epson. Thi^Jet. DeskJet. 
Laseqet. BMP. PCX. EPS. Interleaf 
User Interface menus in multiple languages. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPE REFERENCE 63 




Oscilloscopes 

TDS SERIES 



Selection Guide: 


TDS 654C 


TDS 6S0C 


TDS 684C 


TDS 694C 


TDS 820 


Tvdc 


DSO 


DSO 


DSO 


DSO 


Sampling 


Simal Acauisition System 


Bandwidth 


500 MHz 


1 GHz 


1 GHz 


3 GHz 


6-8 GHz*' 


Channels 


4 


2+2 


4 


4 


2 


Sample Rate: 1 ch. 


5GS/S 


5GS/S 


5 GS/s 


10 GS/s 


50kS/s 


2 ch. 


5GS/S 


5 GS/s 


5 GS/s 


10 GS/s 


50 kS/s 


3, 4 ch. 


5GS/S 


- 


5GVs 


10 GS/s 


- 


Record Length: Std. 


15K pts. 


15K pts. 


I5K pts. 


30K pts. 


15K pts. 


OpL 








120K pts. 





Vert. Resolution: Normal 


8 Bits 


8 Bits 


8 Bits 


8 Bits 


14 Bits 


w/ Averaging 


11 Bits 


11 Bits 


11 Bits 


11 Bits 




Vert. Sensitivity (/div) 


1 mV-10 V 


1 mV-10 V 


1 mV-10 V 


10 mV - 1 V 


2 mV-200mV 


Vertical Accuracy 


±1.5% 


±1.5% 


±1.5% 


±1% 


±0.7% 


Max Input Voltage (1 


300 V Cat II 


300 V Cat II 


300 V Cat II 


5Vrms(50n)*" 


±6V 


Linear Dynamic Range 


±5 div 


±5 div 


±5 div 


±5 div 


±5 div 


BW Limit 


20, 250 MHz 


20, 250 MHz 


20. 250 MHz 






Time Base: Range 


200 ps - 10 s/div 


200 ps - 10 s/div 


200 ps - 10 s/div 


100 ps - 10 s/div 


20 ps - 2 ms/div 


Accuracy 


100 ppm 


100 ppm 


100 ppm 


10 ppm 


0.1%+15ps 


Delta Time Measurement Accuracy*^ 


±50 ps @ 5 GS/s 


±50 ps @ 5 GS/s 


±50 ps @ 5 GS/s 


±15 ps @ 10 GS/s 




Peak Detection 


Ins 


Ins 


Ins 


loops 




rhflnnpl Dpskew 


±25 ns 


±25 ns 


±25 ns 


±25 ns 







Trigger Jitter*'^ 


8ps 


Bps 


Bps 


Bps 




Trigger Conditioning 


HP, LF, 


HF, LF, 


HF, LF, 


HF, LF, 






Noise Reject 


Noise Reject 


Noise Reject 


Noise Reject 




Types: Edge 


Std. 


Std. 


Std. 


Std. 


Std. 


Pattem/State 


4 inputs 


4 inputs 


4 inputs 


4 inputs 




Setup & Hold 


Std. 


Std. 


Std. 


Std. 




Pulse Width 


Std. 


Std. 


Std. 


Std. 




Glitch 


1 ns 


1 ns 


1 ns 


1 ns 




Runt Pulse 


Std. 


Std. 


Std. 


Std. 




Slew Rate 


Std. 


Std. 


Std. 


Std. 




Time Out 


Std. 


Std. 


Std. 


Std. 




External 


Std. 


Std. 


Std. 


Std. 


Std. 


Video*® 


Opt 


Opt 


Opt 






Si«ial Processine 


Modes: Delay by Tim^Event 


Std. 


Std. 


Std. 


Std. 




Auto. Measurements 


29 


29 


29 


29 


27 


Math 


+r,x,-*-,inv 


+,-,x,+,inv 


+.-X+MN 


+,*,x,+,inv 


+,-A+rinv 


Envelope 


Std. 


Std. 


std. 


Std. 


Std. 


Average 


Std. 


Std. 


Std. 


Std. 


Std. 


Interpolation*^ 


Std. 


Std. 


Std. 


Std. 


Std. 


FFT, Int, Diff. 


Std. 


Std. 


Std. 


Std. 


OpL 


Limit Test 


Std. 


Std. 


Std. 


Std. 


Std!., 



64 



OSCILLOSCOPE REFERENCE 



www.tektronlx.com/Measurement/Kopes/ 



Oscilloscopes 

TDS SERIES 



->> r X V ; V -•V'XVVVV- r ■ .-s?ra;«cwsc«ow»s^ 





TDS 654C 


TDS 680C 


TDS 684C 


TDS 694C 


TDS 820 




General 


Display Monitor 


Color 


Mono 


Color 


Color 


Mono 




Inf. Persist, Vectors, Dots, YT, XY 


Std. 


Std. 


Std. 


Std. 


Std. 




Data Ports: VGA Out 


Std. 


Std. 


Std. 


Std. 






GPIB 


Std. 


Std. 


Std. 


Std. 


Std. 




R5232 


Std.*8 


Std.^8 


Std.*8 


Std. 


Opt*« 




Centronics 


Std. 


Std. 


Std. 


Std. 


Opt 




Hardcopy/Export Formats*^ 


Std. 


Std. 


Std. 


Std. 


std. 




Disk Drive (3.5 In.) 


Std. 


Std. 


Std. 


Std. 






Online Help 


Std. 


Std. 


Std. 


Std 


Std. 




Standard Probes 


4ea 


None 


None 


None 


None 





P6243 
1 GHz, lOX 
FET 



TDS SELECTION GUIDE FOOTNOTES 

With Option ID: Bandwidth = 8 GHz. Vertical 
Sensitivity - ImV - lOOmV/div. Max Input = 
±3V no pre-trigger. 

Optional record length on TDS520D/724D is: 
Opt. IM: 250K pts (1-CH), 130K pts per channel 
(2-CH): Opt. 2M: 4M pts (1-CH), 2M pts (2-CH). 
Optional record length 
TDS 580D/754D/784D/794D: Opt IM: 

500K pts (1-CH), 250K pts per channel 
(2-CH), 130K pts (3-, 4-CH). Opt 2M: 8M pts 
(1-CH), 4M pts (2-CH), 2M pts (3-, 4-CH). 
Maximum number of 50 point frames is 372 
(1489 with Opt. 2M installed). Frame lengths 
50 -50,000 points. 

TDS 400A triggered and untriggered roll. 

TDS 3000 and TDS 200 untriggered roll only. 




100 BaseT signal testing with standard com- 
munications mask. 



*6 TDS 3000: NTSC. PAL; TDS 200: Une, Field; 
TDS 400A: NTSC, PAL. SECAM; 

TDS 500D/600C/700D: NTSC, PAL. SECAM, 
HDTV. FlexFormaP'*. 

Selectable Sin (x)/x, linear. TDS 3000, TDS 200: 
Sin (x)/x only. 

** Talk mode only, for hardcopy purposes. 
Supported formats: TIFF. BMP. PCX, RLE. 
Interleaf (IMG). PostScript. LaserJet, Epson, 
Thinkjet, DeskJet, DPU411/412. 

TDS 3000/400A/500D/600C/700D also support 
Spreadsheet. MathCad^'^ waveform formats. 
TDS 200 support: Epson. Thinkjet, DeskJet, 
LaserJet, BMP. PCX. EPS, Interleaf 
User Interface menus in multiple languages. 




GSM Signal. The second ring shows 
attenuated slot. 



Certain restrictions on range apply based on 
other instrument settings. Consult data sheets 
for details. 

‘^^XYZ display mode not available on the 
TDS 520D and TDS 724D. 

Derate at 20 dB/decade above 1 MHz. 

Assumes measurement of a 2 ns wide pulse. 
See individual product specification for com- 
plete formula. 

Typical. 

Option XL is mandatory for all TDS 400 Series. 
TDS 2MM provides four additional automatic 
measurements and FFT analysis. 




8VSB Eye Pattern. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPE REFERENCE 65 






Oscilloscopes 

TDS SERIES 



Selection Guide; 


TDS 2IO*w 


TDS 220*’® 


TDS son*" 


TDS 3032*" 


TDS 3052*" 


TDS 420A*’« 


TDS 430A*'® 


TDS 460A*’« 




TDS 224*’® 


TDS 3014*“ 


TDS 3034*" 


TDS 3054*" 










DSO 


DSO 


DPO 


DPO 


DPO 


DSO 


DSO 


DSO 


•in 

Cional ArnuisHifin Svstem — 


Bandwidth 


60 MHz 


100 MHz 


100 MHz 


300 MHz 


500 MHz 


200 MHz 


400MHz 


400 MHz 


Channels 


2 


2 (TDS 220) 


2 (TDS 3012), 


2 (TDS 3032), 


2 (TDS 3052), 


4 


2 


4 




4 (TDS 224) 


4 (TDS 3014) 


4 (TDS 3034) 


4 (TDS 3054) 









Sample Rate: 1 ch. 

2 ch. 


1 GS/s 
IGS/S 


1 GS/s 
1 GS/s 


1.25 CS/s 
1.25 CS/s 


2.5 GS/s 
2.5 GS/s 


5 GS/s 
5 CS/s 


100 MS/s 
100 MS/s 


100 MS/s 
100 MS/s 


100 MS/s 
100 MS/s 


3, 4 ch. 


1 CS/s (TDS 224) 


1.25 CS/s 


2.5 C^s 


5 GS/s 


100 MS/s 




100 MS/s 


Record Length: Std. 

Opt 


2.5 K pts. 


2.5 K pts. 


10K pts. 


10K pts. 


10K pts. 


120K pts. (XL) 


120K pts. (XL) 


120K pts. (XL) 


Vert. Resolution: Normal 

w/Averaging 
w/Hi Res 


8 Bits 
8 Bits 


8 Bits 
8 Bits 


9 Bits 
>13 Bits 


9 Bits 
>13 Bits 


9 Bits 
>13 Bits 


8 Bits 
11 bits 
>12 Bits 


8 Bits 
11 bits 
>12 Bite 


9 Bite 
11 bite 
>12 bite 




2 mV - 5 V 


2mV-5V 


1 mV-lOV 


1 mV- 10 V 


1 mV -10 V 


1 mV -10 V 


1 mV- 10 V 


1 mV-IOV 


Vertical Accuracy 


±3% 


±3% 


±2% 


±2% 


±2% 


±1.5% 


±1.5% 


±1.5% 


Max Input Voltage(1 MO) 


300 Vrms 


300 Vrms 


150 Vrms 


150 Vrms 


150 Vrms 


300 Vrms 


300 Vrms 


300 Vrms* " 


1 inpar Dvnamic Ranse 


±5 div 


±5 div 


±5 div 


±5 div 


±5 div 


±5 div 


±5 div 


±5 div 


BW Limit 


20 MHz 


20 MHz 


20 MHz 


20, 150 MHz 


20, 150 MHz 


20, 100 MHz 


20, 100 MHz 


20, 100 MHz 


L/iV ^llllli 

Time Base: Range 


5 ns - 5 s 


5 ns - 5 s 


4 ns - 10 s 


2 ns - 10 s 


1 ns - 10 s 


1 ns - 20 s 


1 ns - 20 s 


2 ns - 20 s 


Accuracy 


100 ppm 


100 ppm 


200 ppm 


200 ppm 


200 ppm 


50 ppm 


50 ppm 


50 ppm 


Ppak Detection 


10 ns 


10 ns 


1 ns 


1 ns 


1 ns 


10 ns 


10 ns 


10 ns 


lCOI\ L/dv^ilwll 

Roll Mode*® 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Std, 


Std. 


r\vii 

rhannpl Deckew 




_ 


±10 ns 


±10 ns 


±10 ns 


- 


- 


- 


TrlotfArino 


Trigger Conditioning 


HE, LF. 
Noise Reject 


HF, LF, 
Noise Reject 


HF, LF 
Noise Reject 


HF,LF 
Noise Reject 


HF,LF 
Noise Reji^ 


HF, LF 
Noise Reject 


HF,LF 
Noise Reject 


HF. LF 
Noise Reject 


Types: Edge 

Pattern/State 


Std. 


Std. 


Std. 

Opt. (TDS 3012), 


Std. 

Opt (TDS 3032), 


Std. 

Opt (TDS 3052), 


Std. 


Std. 


Std. 






Std. (TDS 3014) 


Std. (TDS 3034) 


Std. (TDS 3054) 








Setup & Hold 
Pulse Width 


- 


- 


Opt. (TDS 3012), 


Opt. (TDS 3032) 


Opt. (TDS 3052) 


- 


- 


- 






Std. (TDS 3014) 


Std. (TDS 3034) 


Std. (TDS 3054) 








Glitch 


_ 


_ 


Opt. (TDS 3012), 


Opt (TDS 3032) 


Opt (TDS 3052) 


- 




~ 






Std. (TDS 3014) 


Std. (TDS 3034) 


Std. (TDS 3054) 








Runt Pulse 


_ 


- 


Opt. (TDS 3012), 


Opt (TDS 3032) 


Opt (TDS 3052) 


- 


~ 








Std. aDS 3014) 


Std. (TDS 3034) 


Std. (TDS 3054) 








Slew Rate 


_ 


_ 


OpL (TDS 3012), 


Opt (TDS 3032) 


Opt (TDS 3052) 


- 










Std. (TDS 3014) 


Std. (TDS 3034) 


Std. (TDS 3054) 









Time Out 
Comm 

External Std. Std. 

Video*® Std. Std. 

Modes: Delay By Time only By Time only 



Opt. 


Opt. 


Opt. 


- 


Std. (TDS 3012) 


Std. (TDS 3032) 


Std. (TDS 3052) 


Std. 


Std. 


Std. 


Std. 


Std- 


Std. 


Std. 


Std. 


Std. 



Std. 


Std. 


Std. 


Std. 


Std. 


Std. 



by Time/Event 



R E 



FERENC 



E 



66 



OSCILLOSCOPE 



www.tektronix.com/Measurenient/scopes/ 



Oscilloscopes 

TDS SERIES 



Selection Guide 


TDS 1I0*“ 


TDS 220*“ 


TDS 3012*" 


TDS 3032*» 


TDS 30S2*" 


TDS 420A*“ 


TDS 430A*“ 


TDS 460A*“ 






TDS 224*" 


TDS 3014*“ 


TDS 3034*" 


TDS 3054*" 








Siinial Processing 


Auto. Measurements 


5*17 


5*17 


21 


21 


21 


25 


25 


25 


Math 


+, - 


+, - 


+,-;tinv 


+,*,x,inv 


+r,x,inv 


+,-,x,inv 


+,-,x,inv 


+,-,x,inv 


Envelope 


_ 


- 


Std. 


Std. 


std. 


Std. 


Std. 


Std. 


Average 


Std. 


std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Interpolation*^ 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


FFT, Ini, Dift. 


Opt (FFT)*" 


Opt (FFT)*" 


FFT Opt 
(TDS 3012), 
FFT Std. 


FFT Opt 
(TDS 3032), 
FFT Std. 


FFT Opt 
(TDS 3052), 
FFT Std. 


Std. (Opt XL) 


Std. (Opt XL) 


Std. (Opt. XL) 








ODS 3014) 


(TDS 3034) 


(TDS 3054) 








Limit Test 


- 


- 


- 


- 


- 


Std. 


Std. 


Std. 


General 


Display Monitor 


Mono 


Mono 


Color 


Color 


Color 


Mono 


Mono 


Mono 


Inf. Persist, Vectors, 
Dots,YT,XY 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Data Ports: VGA Out 


- 


- 


Opt 




Opt _ 


Std. 


Std. 


Std. 


GPIB 


Opt 


Opt 


opt 




Opt 


Opt 


Std. 


Std. 


Std. 


RS232 


Opt. 


Opt 


Opt 


Opt. 


Opt. 


std, (Opt XL) 


Std. (Opt XL) 


Std. (Opt XL) 


Centronics 


Opt. 


Opt. 


std. 


std. 


std. 


Std. (Opt XL) 


std. (Opt XL) 


Std. (Opt XL) 


Hardcopy/Export Formats*^ 


Std. 


std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Disk Drive (3.5 in.) 


- 


- 


Std. 


Std. 


Std. 


Std. 


Std. 


Std. 


Online Help 


_ 


_ 


- 


_ 


- 


Std. 


Std. 


Std. 


Standard Probes 


2 ea. 


2 ea. (TDS 220) 


2 ea. (TDS 3012) 


2 ea. (TDS 3032) 


2 ea. (TDS 3052) 


4 ea. 


2 ea. 


4 ea. 




P6112 


4 ea. (TDS 224) 
P6112 


4 ea. (TDS 3014) 
P3010 


4 ea. (TDS 3034) 
P6139A 


4 ea. (TDS 3054) 
P6139A 


P6138A 


P6138A 


P6138A 




100 MHz, 


100 MHz, 


100 MHz 


500 MHz 


500 MHz 


400 MHz 


400 MHz 


400 MHz 




lOX Passive 


lOX Passive 


lOX Passive 


lOX Passive 


lOX Passive 


lOX Passive 


lOX Passive 


lOX Passive 



TDS SELEaiON GUIDE FOOTNOTES 

With Option ID: Bandwidth = 8 GHz. Vertical 
Sensitixity - ImV - lOOmV/div. Max Input = 
±3V, no pre-trigger. 

Optional record length on TDS 520D/724D is: 
Opt. IM: 250K pts (1-CH), 130K pts per channel 
(2-CH): Opt. 2M: 4M pts (1-CH). 2M pts (2-CH). 
Optional record length 
TDS 580D/754D/784D/794D: Opt IM: 

500K pts (1-CH). 250K pts per channel 
(2-CH). 130K pts (3-. 4-CH). Opt 2M: 8M pts 
(1-CH). 4M pts (2-CH). 2M pts (3-. 4-CH). 




The TDS 400A Digital Storage Oscilloscopes 
and AM 503S Current Probe System. The 
AM 503S and TDS 400A combination are 
well-suited for measuring currents in 
switching supplies. 



*** Maximum number of 50 point frames is 372 
(1489 with Opt. 2M installed). Frame lengths 
50 -50.000 points. 

TDS 400A triggered and untriggered roil. 

TDS 3000 and TDS 200 untriggered roll only. 
TDS 3000: NTSC. PAL: TDS 200: Une. Field: 
TDS 400A: NTSC. PAL. SECAM: 

TDS 500D/600C/700D: NTSC. PAL. SECAM. 
HDTV FlexFormat"* . 

Selectable sin(x)/x. linear. TDS 3000. TDS 200: 
sin(x)/x only. 

Talk mode only, for hardcopy purposes. 
Supported formats: TIFF. BMP. PCX. RLE. 
Interleaf (IMG). PostScript. LaserJet. Epson. 
Thinkjet. DeskJet. DPU41 1/412 (not TDS 3000). 
TDS 3000/400A/500D/600C/700D also support 
Spreadsheet. MathCad '’ waveform formats. 




TDS 3054 Digital Phosphor Oscilloscope. 



TDS 200 support: Epson. Thinkjet. DeskJet. 
LaserJet. BMP, PCX. EPS, Interleaf 
User Interface menus in multiple languages. 
Certain restrictions on range apply based on 
other instrument settings. Consult data sheets 
for details. 

‘^^XYZ display mode not available on the 
TDS 520D and TDS 724D. 

Derate at 20 dB/decade above 1 MHz. 

Assumes measurement of a 2 ns wide pulse. 
See individual product specification for com- 
plete formula. 

Typical. 

Option XL is mandatory for all TDS 400 Series. 
TDS 2MM provides four additional automatic 
measurements and FFT analysis. 




TDS 200 Series Digital Storage 
Oscilloscopes. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPE REFERENCE 67 





Digital Phosphor Oscilloscopes 

TDS 500D • TDS 700D 




For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 

C€ 

^Tsersooi 



Tektronix measurement 
products are manufactured in 
ISO registered facilities. 




Product(s) complies with IEEE 
Standard 488.1-1987, RS-232-C, 
and with Tektronix Standard 
Codes and Formats. 



Features - Benefits Applications 



2 GHz, 1 GHz and 500 MHz 
Bandwidths 

Sample Rates to 4 GS/s 

Captures and Displays up to 
200,000 Waveforms per Second 

2 or 4 Channels 

1% Vertical Accuracy 

8-Bit Vertical Resolution, Over 
1 1 -Bits with Averaging and Over 
13-Bits with Hi-res 

1 ns Peak Detect 
1 mV/div to 10 V/div Sensitivity 

Up to 1.5 GHz Differential 
Measurements 

Channel Deskew 

Record Lengths to 8 M Points 

Floppy Disk Storage 

Iomega Zip and Zip Plus Drive 
Compatible 

Advanced Triggering 

29 Automatic Measurements and 
Measurement Statistics 

FFT and Advanced Math 
Histograms 
Histogram Statistics 
Limit Test 

FastFrame™ Time Stamp 

Communication Signal Analysis 
Including Mask Testing and 
SONET/SDH and Fibre Channel 
Optical Reference Receivers 

Full GPIB Programmability 

3 Year Warranty 
CE Marking 



Communication Compliance 
Testing 

Digital Design and Debugging 
Jitter Analysis 
Fast Edge Characterization 
Video Design and Debug 
Disk Drive Measurements 
Power Measurements 



68 OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 








Digital Phosphor Oscilloscopes 

TDS 500D • TDS 700D 



The TDS 500D/TDS 700D 
Family of Digital Phosphor 
Oscilloscopes 

The TDS 500D/700D oscilloscopes are 
the first in the TDS family of Digital 
Phosphor Oscilloscopes (DPOs) designed 
to keep pace with current and evolving 
needs in advanced electronic design and 
debug. DPOs deliver a new level of 
insight that makes dealing with complex 
signals elementary - a new level of 
insight that must be seen to be believed. 

DPOs capture, store, display and ana- 
lyze, in real-time, three dimensions of 
signal information: amplitude, time and 
distribution of amplitude over time. 

The benefit of this new third dimension 
of information is an interpretation of 
the signal dynamics, including instanta- 
neous changes and the frequency of 
occurrence displayed in the form of 
quantitative intensity information. 

HIGH FIDELITY SIGNAL ACQUISITION 

The high waveform capture rate of the 
TDS 500D/700D DPO, together with its 
high bandwidth and sample rate, deliv- 
ers instantaneous signal feedback to 
show the true signals that other scopes 
may be missing. The DPO acquisition 
acquires over 1000 times more data 
than traditional DSOs, allowing the 
capture of complex signals, reducing 
debugging times from hours to seconds. 

Channels can be transparently com- 
bined to achieve higher sample rates 
and longer record lengths. The record 
length can be optionally increased to 8 
M points, providing a high-resolution 
representation of the signal over a long 
period of time. 

All of the TDS products provide wide 
dynamic range, flat response, fast over- 
drive recovery, calibrated DC offset, 1 
mV/div sensitivity (10 mV maximum 
sensitivity on TDS 794D), 1 ns peak 
detect and internal calibration. 

POWERFUL AND FLEXIBLE TRIGGERING 

In addition to basic triggering such as 
edge and pulse-width, these Digital 
Phosphor Oscilloscopes have several 
trigger modes tailored for specific 
design and debug applications. Logic 
and pulse triggers, including 
setup/hold, glitch, slew rate and time- 
out triggers, capture hard-to-catch digi- 



tal design problems. The optional video 
trigger provides line and field selection 
for NTSC, PAL and HDTV standards. 
The optional communications trigger 
capability addresses needs to acquire a 
wide variety of AMI, CMI. NRZ and 
Ethernet communication signals. 

ADVANCED PERFORMANCE FEATURES 

Automatic Measurements eliminate the 
need for manually measuring the wave- 
form against the graticule or with cur- 
sors. Measurement gating, (gating not 
available for DPO operation) allows the 
user to select a specific part of the live 
waveform for measurement. 
Measurement statistics (min, max, 
mean and standard deviation), give 
additional information about the varia- 
tions in the measurements over time 
(for example, worst case excursions), 
increasing the confidence in the quality 
of the measurements. 




The horizontal histogram of the selected 
region of the waveform shows the character 
of a metastable flip-flop output. 



Waveform Histograms allow the exami- 
nation of the statistical nature of the 
signal. Horizontal histograms, which 
are useful for evaluating signal jitter, 
sample the waveform within a specified 
region, sort the values into time bins 
and plot the accumulated bin values 
versus time. Vertical histograms, which 
are useful for evaluating signal noise, 
sample the waveform within a specified 
region, sort the values into amplitude 
bins and plot the accumulated bin val- 
ues versus amplitude. 

For histograms of DPO acquisitions 
(both live and stored), the specified 
region can be repositioned and will 
update to reflect the underlying 3 
dimensional data base (32 bits in shal- 



low mode, 64 bits in deep mode). 

Communication Mask Testing (available 
as an option) allows mask compliance 
testing of a wide variety of communica- 
tion signals to industry standards. 
Specialized measurement accessories, 
unique trigger modes, built-in optical 
reference receiver filters, mask autoset 
and mask violation counting make these 
measurements easily and repeatahly. 

APPLICATIONS SOFTWARE PACKAGES 

TDSDDMl provides users with industry 
standard measurements such as Track 
Average Amplitude (TAA), 50% Pulse 
Width (PW^*^), Non-Linear Transition 
Shift (NLTS) and Signal to Noise Ratio 
(SNR). This capability gives disk drive 
designers direct measurements in 
industry standard terminology. TDSP- 
WRl gives designers interested in 
power consumption applications the 
ability to automatically calculate True 
Power, Apparent Power, Power Factor, 
Instantaneous Power and Energy to 
eliminate manual calculations. TDSJITl 
performs a suite of jitter measurements 
with unprecedented accuracy on single- 
shot waveforms. Jitter information can 
be displayed as statistics, histograms or 
profiled. TDSPSMl introduces a revolu- 
tionary way for making timing measure- 
ments by providing statistics on specific 
data and clock edges that are fully time- 
correlated. This application also per- 
forms automated AC timing measure- 
ments on all parameters in single-shot 
acquisitions. TDSCEMl performs a 
suite of automated eye diagram meas- 
urements on SONET/SDH and Fibre 
Channel standards. These measure- 
ments include eye height, eye width 
and quality factor. TDSCPMl performs 
automated parametric measurements of 
pulse amplitude, spectral power and 
pulse symmetry to standards require- 
ments. Standards include ANSI Tl.102 
and ITU-T G.703. 

COMPLEMENTARY MEASUREMENT 
ACCESSORIES 

Tektronix provides a wide range of 
measurement accessories optimized for 
the TDS family. These accessories are 
designed to operate via the 
TEKPROBE® interface, which provides 
power and automatic scaling, to com- 
plete the DPO measurement solutions. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPES 69 





Digital Phosphor Oscilloscopes 

TDS 500D • TDS 700D 



Active Probes such as the P6249 and 
P6245 active prohes were designed 
specifically for the DPO products. For 
example, the P6249 (4 GHz prohe only) 
is capable of achieving the full 2 GHz 
bandwidth on a TDS 794D, while pro- 
viding low loading. 

The P6339A Buffered Passive Probe is 
designed to provide 500 MHz bandwidth 
at the probe time for the TDS 794D. 

Optical-to-electrical Converters (P6701B, 
P6703B) allow convenient analysis of 
optical transmission signals with the 
oscilloscope. Both short- and long-wave- 
length optical converters are compatible 



with the industry-standard wavelengths 
for SONET/SDH and Fibre Channel. 

High-bandwidth Differential Probes 
(P6248, P6247) enable high bandwidth 
(up to 1.7 GHz) differential measure- 
ments while maintaining high common- 
mode rejection. 

Current Probes such as the TCP202 and 
High-Voltage Differential Probes such 
as the P5205 and P5210 allow safe, 
high-power measurements. Direct Probe 
Readouts use information from the 
probes to display measurements in 
units of Amps, Volts and Watts. 



SOPHISTICATED DOCUMENTATION 

Save screen displays in a number of 
standard desktop publishing formats to 
the internal 3.5 in. DOS-compatible 
floppy disk drive. Transfer the disk to a 
PC for import into word processing 
applications. Make hardcopies directly 
to monochrome or color printers and 
plotters connected to the computer net- 
work (LAN), GPIB, RS-232 or Centronics 
ports, or acquire waveforms, screen dis- 
plays and scope settings using Tektronix 
WaveStar™ software running on a PC 
interfaced to the GPIB port. 



Characteristics 



TDS 500D/700D 


Series Electrical Characteristics 

TDS 794D TDS 784D TDS 754D TDS 724D 


TDS 580D 


TDS 540D 


TDS 520D 


Bandwidth 


2CHz« 


1 GHz*’ 


500 MHz*2 


500 MHz*2 


1 GHz 


500 MHz« 


500 MHz« 


# Channels 


4 


4 


4 


2 + 2 aux. 


4 


4 


2 + 2 aux. 


# Samplers 


4 


4 


4 


2 


4 


4 


2 


Max Real-time Sample Rate 


1 Channel 


4GS/S 


4 GS/s 


2CS/S 


2CS/S 


4 GS/s 


2 GS/s 


2CS/S 


2 Channels 


2CS/S 


2 GS/s 


2GVs 


1 GS/s 


2 GS/s 


2 GS/s 





3-4 Channels 


IGS/S 


1 GS/s 


iGVs 


NA 


1 cys . 


1 GS/s 


NA 


Equivalent-time Sample Rate 


250 GS/s max. 


250 CS/s max. 


100 GS/s max. 


100 GS/s max. 


250 GS/s max. 


100 GS/s max. 


100 GS/s max. 


Maximum Record Leneth 


1 Channel 


50 K 

(OpL 1M:500K, 
Opt. 2M: 
8M) 


50 K 

(Opt IM: 500 K, 
Opt 2M: 
8M) 


50 K 

(Opt IM: 500 K. 
Opt 2M: 
8M) 


50 K 

(Opt IM: 250 K, 
Opt 2M: 
4M) 


50 K 

(Opt IM: 500 K, 
Opt 2M: 
8M) 


50 K 

(Opt IM: 500 K, 
Opt 2M: 
8M) 


50 K 

(Opt IM: 250 K, 
OpL 2M: 




2 Channels 


50 K 

(Opt. IM: 250 K, 
Opt. 2M: 
4M) 


50 K 

(Opt IM: 250 K, 
Opt 2M: 
4M) 


50 K 

(OptlM; 250 K, 
OpL 2M: 
4M) 


50 K 

(Opt IM: 130 K, 
Opt 2M: 
2M) 


50 K 

(Opt IM: 250 K, 
Opt 2M: 
4M) 


50 K 

(Opt IM: 250 K. 
Opt 2M: 
4M) 


50 K 

(Opt IM: 130 K, 
Opt 2M: 
2M) 


3-4 Channels 


50 K 

(Opt IM: 130 K, 
OpL 2M: 
2M) 


50 K 

(Opt IM: 130 K, 
Opt 2M: 
2M) 


50 K 

(Opt. IM: I30K, 
Opt 2M; 
2M) 


NA 


50 K 

(Opt IM: 130 K, 
Opt 2M: 
2M) 


50 K 

(OptlM: 130 K. 
Opt 2M: 
2M). 


NA 


Max Sample Rate Window*^ 


2 ms 


2 ms 


4 ms 


4 ms 


2 ms 


4 ms 


4 ms 


Display 


NuColor"* Display 


NuColor™ Display 


NuColor™ Display 


NuColor™ Display 


monochrome 


monochrome 


monochrome 



In 50 n mode: 5 mV/div: 750 MHz. 2 mV/div: 600 MHz. 1 mV/div: 500 MHz. Reduce the upper bandwidth frequencies by 5 MHz for each degree C 



above 30°C. 



In 50 mode: 1 mV/div: 450 MHz. Reduce the upper bandwidth frequencies by 2.5 MHz for each degree C above 30°C. 
Single-channel operating at full sample rate and maximum record length (Opt. 2M). 

*‘* > 10 mV/div in 50 il mode. 



*^Reduce the upper bandwidth frequency by 20 MHz for each degree C above OO'^C. 



ACQUISITION MODES 

DPO - Captures and displays complex wave- 
forms, random events and subtle patterns in 
actual signal behavior. By acquiring up to 100 M 
points/sec TDS 794D, TDS 784D, TDS 754D, 

TDS 580D, TDS 540D (SOM points/sec; TDS 724D 
and TDS 520D) DPOs are able to provide 
3 dimensions of signal information, in real-time; 
amplitude, time, and the distribution of amplitude 
over time. The DPX™ Waveform Imaging 



Processor automatically selects record lengths 
between 500 and 500,000 points and sample rate 
up to 1 GS/s, based on horizontal time base set- 
ting, to optimize displayed sample density. 

Peak Detect - High frequency and random 
glitch capture. Captures glitches of 1 ns using 
acquisition hardware at ail real-time sampling 
rates. 

Sample - Sample data only. 

Envelope - Max/min values acquired over 
one or more acquisitions. 



Average - Waveform data from 2 to 10,000 
(selectable) is averaged. 

Hi-res - Vertical resolution improvement and 
noise reduction on low-frequency signal (e.g., 
12-Bits typical). 

FastFrame"” Time Stamp - Acquisition 
memory size segmentable with trigger rate up 
to 80,000 per second from 50 to 5,000 points 
per frame (independent of the number of 
channels). 



70 OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 




Digital Phosphor Oscilloscopes 

TDS 500D • IDS 700D 



TDS 500D/700D 


Series Vertical System 

TDS 794D TDS 784D TDS 754D 


TDS 724D 


TDS S80D 


TDS 540D 


TDS 520D 


Sensitivity 


10 mV/div to 


mV/div to 


1 mV/div to 


1 mV/div to 


1 mV/div to 


1 mV/div 


1 mV/div to 




1 V/div 


10 V/div 


10 V/div 


10 V/div 


10 V/div 


to 10 V/div 


10 V/div 




(50 Q mode) 


1 (1 Mi2 mode), 


(1 MQ mode). 


(1 MQ mode). 


(1 MQ mode). 


(1 MQ mode). 


(1 MQ mode), 1 






1 mV/div to 


1 mV/divto 


1 mV/div 


1 mV/div 


1 mV/div to 


mV/div to 






1 V/div 


1 V/div 


to 1 V/div 


to 1 V/div 


1 V/div 


1 V/div 






(50 n mode) 


(50 Q mode) 


(50 Q mode) 


(50 Q mode) 


(50 Q mode) 


(50 Q mode) 


DC Gain Accuracy 


±1.0% 


±1.0% 


±1.0% 


±1.0% 


±1.0% 


±1.0% 


±1.0% 




(0.7% typical) 


(±0.7% typical) 


(±0.7% typical) 


(±0.7% typical) 


(±0.7% typical 


(±0.7% typical) 


(±0.79t) typical) 


Effective Bits (typical) 


5.0 (2 GHz 


5.5 (1 GHz 


6.8 (500 MHz 


6.8 (490 MHz 


5.5 (1 GHz 


6.8 (500 MHz 


6.8 (490 MHz 




@ 4 CS/s), 9.7 


@ 4 GS/s), 9.7 


@ 2 GS/s), 9.7 


@ 2 GS/s), 9.7 


@ 4 GS/s). 9.7 


@ 2 GS/s), 9.7 


@ 2 GS/s). 9.7 




with Hi-res (1 MHz 


with Hi-res (1 MHz 


with Hi-res (1 MHz 


with Hi-res (1 MHz 


with Hi-res (1 MHz 


with Hi-res (1 MHz 


with Hi-res (1 MHz 




@ 10 MS/s) 


@ 10 MS/s) 


@ 10 MS/s) 


@ 10 MS/s) 


@ 10 MS/s) 


@ 10 MS/s) 


@ 10 MS/s) 


Vertical Resolution 




8-Bits (256 levels on 10.25 divisions). >11 -Bits with averaging, >13-Bits typical with Hi-res 








(TDS 794D, TDS 784D, TDS 580D), >12-Bits typical with Hi-res (TDS 754D, TDS 724D, TDS 540D, TDS 520D) 




Position Range 


±5 


±5 


±5 


±5 


±5 


±5 


±5 




divisions 


divisions 


divisions 


divisions 


divisions 


divisions 


divisions 


Offset Range 




±1 Vfrom 1 


mV to 100 mV/div, ±10 V from 101 mV to 1 V/div, ±100 V from 1.01 V to 10 V/div 








fTDS 784D. TDS 754D. TDS 724D. TDS 580D. TDS 540D. TDS 520D) ±0.5 V from 10 mV to 50 mV/div 




Analog Bandwidth 


Full only 


20 MHz, 


20 MHz, 


20 MHz, 


20 MHz, 


20 MHz. 


20 MHz, 


Selections 




250 MHz, full 


250 MHz, full 


250 MHz. full 


250 MHz, full 


250 MHz, full 


250 MHz, full 


Input Coupling 


DCGND 


AC, DC. GND 


AC. DC, GND 


AC, DC. GND 


AC. DC, GND 


AC, DC, GND 


AC, DC, GND 


Input Impedance Selections 






1 MQ in parallel with 10 pF, or 50 Q (AC and DC coupling) 








fTDS 784D. TDS 754D. TDS 724D. TDS 580D, TDS 540D. TDS 520D) 50 Q only (DC coupling only) (TDS 794D only) 


AC-coupled Low 


N/A 


^0 Hz 


^0 Hz 


<10 Hz 


<10 Hz 


<10 Hz 


<10 Hz 


Frequency Limit 




when AC 1 MQ 


when AC 1 MQ 


when AC 1 MQ 


when AC 1 MQ 


when AC 1 MQ 


when AC 1 MQ 






coupled. 


coupled. 


coupled. 


coupled. 


coupled. 


coupled. 






^00 kHz 


^00 kHz 


^00 kHz 


^00 kHz 


^00 kHz 


^00 kHz 






when AC 50 Q 


when AC 50 Q 


when AC 50 Q 


when AC 50 Q 


when AC 50 Q 


when AC 50 Q 






coupled. 


coupled. 


coupled. 


coupled. 


coupled. 


coupled. 


Channel Isolation 






>100:1 at 100 MHz and >30:1 at the rated bandwidth 






Max. Input Voltage 


5 Vrmst with 


300 V CAT II 


300 V CAT II 


300 V CAT II 


300 V CAT II 


300 V CAT II 


300 V CAT 11 




peaks <± 20 Volts 


±400 V (peak). 


±400 V (peak). 


±400 V (peak). 


±400 V (DC + 


±400 V (peak). 


±400 V (peak). 






Derate at 


Derate at 


Derate at 


peak AC). Derate 


Derate at 


Derate at 






20 dB/decade 


20 dB/decade 


20 dB/decade 


at 20 dB/decade 


20 dB/decade 


20 dB/decade 






above 1 MHz. 


above 1 MHz. 


above 1 MHz, 


above 1 MHz. 


above 1 MHz. 


above 1 MHz. 






1 MQ or GND 


1 MQ or GND 


1 MQ or GND 


1 MQ or GND 


1 MQ or GND 


1 MQ or GND 






coupled. 


coupled. 


coupled. 


coupled. 


coupled. 


coupled. 



TDS 500D/700D Series Timebase System 

TPS 540P/TPS 520P TPS 794P TPS 784P/TPS 580P TPS 754P/TPS 724P 



Time Bases 


Main, delayed 


Main, delayed 


Main, delayed 


Time Base Ranee 


200 ps to 10 s/div 


200 ps to 10 s/dIv 


500 ps to 10 s/div 


Time Base Accutacv *25 ppm (over any interval >1 ms) 


Delta Time Measurement Accuracy 




±(0.15/sample rate) + (25 ppm x [readingl) 




Trigger Jitter 


7 ps (typical) 


7 ps (typical) 


8 ps (typical) 


Pre-trigger Position 




0% to 100% of any record 




Delay Between Channels 




<50 ps (any 2 channels with equal V/dIv and coupling) 





Single Sequence - Use RUN/STOP button to 
capture a single triggered acquisition at a time, 
which may be automatically saved to NVRAM 
with AutoSave. 

TRIGGER SYSTEM 
Triggers - Main and delayed. 

Main Trigger Modes - Auto, Normal, Single. 
Delayed Trigger - Delayed by time, events, 
or events and time. 

Time Delay Range - 16 ns to 250 s. 

Events Delay Range - 1 to 9,999,999 events. 



External Rear Input - >1.5 kW; Max input 
voltage is ±20 V (DC + peak AC). 

TRIGGER TYPES 
EDGE (Main and Delayed) - 

Conventional level-driven trigger. Positive or 
negative slope on any channel or rear panel 
auxiliary input. Coupling selections: DC, AC, 
noise reject, HF reject, LF reject. 

LOGIC (Main) - 

PATTERN: Specifies a logical combination 
(AND, OR, NAND, NOR) of the four input chan- 



nels (high, low, don't care). Trigger when pat- 
tern stays true or false for a specified time. 
STATE: Any logical pattern of channels 1, 2, and 
3 (AUX1 on 2-CH products) plus a clock edge 
on channel 4 (AUX2 on 2-CH products). 
Triggerable on rising or falling clock edge. 
SETUP/HOLD: Trigger on violations of both 
setup time and hold time between clock and 
data which are on two input channels. 

PULSE (Main) - 

GLITCH: Trigger on or reject glitches of positive, 
negative, or either polarity. Minimum glitch 



www.tektronix.com/Measureinent/scopes/ 



OSCILLOSCOPES 71 



Digital Phosphor Oscilloscopes 

TDS 500D • TDS 700D 



width is 1.0 ns (typical) 2 ns (warranted) with 
200 ps resolution. 

RUNT: Trigger on a pulse that crosses one 
threshold but fails to cross a second threshold 
before crossing the first again. 

WIDTH: Trigger on width of positive or negative 
pulse either within or out of selectable time 
limits (1 ns to 1 s). 

SLEW RATE: Trigger on pulse edge rates that 
are either faster or slower than a set rate. 

Edges can be rising, falling or either. 

TIMEOUT: Trigger on an event which remains 
high, low, or either, for a specified time peri- 
od, selectable from 1 ns to 1 s, with 200 ps 
resolution. 

COMM (Optional) - 

AMI: Trigger on standard communications sig- 
nals (including DSl, DSIA, DSIC, DS2, DS3, El, 
E2, E3, STS-1 or a custom bit rate). Select 
between "Isolated ones" (positive or negative) 
and eye diagrams. 

CMI: Trigger on standard communications sig- 
nals (including STS-3, STMIE, DS4NA, E4 or a 
custom bit rate). Select between positive or neg- 
ative one pulses, zero pulses and eye diagrams. 
NRZ: Trigger on standard communications sig- 
nals (including OCl/STMO, OC3/STM1, 
OC12/STM4, E5, FC133, FC266, FC531, FC1063, 
FDDI HALT, 143 Mb/s serial digital composite 
video, 270 Mb/s serial digital component video 
or a custom bit rate). Select between an eye 
diagram, rising or falling edges or any of eight 
3-Bit serial patterns. 

VIDEO (Optional) - 
Trigger on a particular line of individual, 
odd/even, or all fields. Trigger on a specific 
pixel of a line by using the video trigger with 
delay by events. Choose positive or negative 
horizontal sync polarity. 

525/NTSC: Choose monochrome or color (stu- 
dio-quality NTSC) sync formats. 

625/PAL: Choose color or monochrome (stu- 
dio-quality PAL) sync formats. 

HDTV: Choose from 1125/60, 1050/60, 

1250/50, and 787.5/60 HDTV formats. 

MEASUREMENT SYSTEM 
Automatic Waveform Measurements - 

Period, frequency, + width, - width, rise time, fall 
time, + duty cycle, - duty cycle, delay, phase, 
burst width, high, low, max. min, peak to peak, 
amplitude, + overshoot, - overshoot, mean, 
cycle mean, RMS, cycle RMS, area, cycle area, 
extinction ratio (ratio, dB, %) and mean optical 
power. Continuous update of up to four meas- 
urements on any combination of waveforms. 
Measurement Statistics - Display minimum 
and maximum or mean and standard devia- 
tion on any displayed single-waveform meas- 
urements. 

Thresholds - Settable in percentage or voltage. 



Gating - Any region of the waveform may be 
isolated for measurement using vertical bars. 
Snapshot - Performs all measurements on 
any one waveform showing results from one 
instant in time. 

Cursor Measurements - Absolute, 

Delta: Volts, Time, Frequency and NTSC IRE 
and line number (with video trigger option). 
Cursor Types - Horizontal bars (volts), verti- 
cal bars (time); operated independently or in 
tracking mode. 

WAVEFORM PROCESSING 
Waveform Functions - Sin(x)/x or linear 
interpolation. Average, Envelope. 

Advanced Waveform Functions (optional on 
TDS 500D) - FFT, Integration, Differentiation. 
Arithmetic Operators - Add, Subtract, 
Multiply, Divide, Invert. 

Autoset - Single-button, automatic setup on 
selected input signal for vertical, horizontal and 
trigger systems. Also automatically normalizes 
signals to standard masks when used with the 
mask testing option. 

Waveform Limit Testing - Compares incom- 
ing or math waveform to a reference wave- 
form's upper and lower limits. 

Waveform Histograms - Both vertical and hor- 
izontal histograms, with periodically updated 
measurements, allow statistical distributions to be 
analyzed over any region of the signal. For his- 
tograms on DPO acquisitions, both live and 
stored, the specified region can be repositioned 
and will update to reflect the underlying 3 dimen- 
sional data base, in both YT and XY modes (32 
bits in shallow mode, 64 bits in deep mode). 
Mask Testing (Optional) - in addition to the 
standard communication masks in the instru- 
ment, the masks can be edited on the screen. 
Together with automatic waveform scaling, the 
mask tests give rapid verification of a digital bit 
stream's conformance to pulse templates and 
eye pattern masks. For optical conformance 
testing, the internal Fibre Channel and 
SONET/SDH optical reference receiver filters 
provide convenient test setup which is compli- 
ant to Industry standards. 

ZOOM CHARACTERISTICS 

The zoom feature allows waveforms to be 
expanded or compressed In both vertical and 
horizontal axes. Allows precise comparison and 
study of fine waveform detail without affecting 
ongoing acquisitions. When used with Hi-res or 
Average acquisition modes. Zoom provides an 
effective vertical dynamic range or 1000 divi- 
sions or 100 screens. Zoom features not avail- 
able on DPO operations. 

Dual Window Zoom - Dual graticules simul- 
taneously show selected and zoomed wave- 
forms. Up to two zoom boxes show areas on 



the selected trace that are being magnified, 
and the two magnified areas can be over- 
lapped for quick comparison. Color of zoomed 
trace matches selected trace. 

DISPLAY CHARACTERISTICS 
Waveform Style - Dots, vectors, variable per- 
sistence from 32 ms to 10 s, infinite persistence, 
and intensified samples. 

Color (TDS 794D, TDS 784D, TDS 754D, 
TDS 724D) - Standard palettes and user- 
definable color for waveforms, text, graticules 
and cursors. Measurement text and cursor col- 
ors matched to waveform. Waveform collision 
areas highlighted with different color. Statistical 
waveform distribution shown with color grad- 
ing through variable persistence. 

Color Grading (TDS 794D, TDS 784D, 

TDS 754D, TDS 724D) - With variable per- 
sistence selected, historical timing information 
is represented by temperature or spectral color 
scheme (or gray scale on TDS 580D, TDS 540D, 
TDS 520D) providing "z-axis" information 
about rapidly-changing waveforms. 

Graticules - Full, grid, cross-hair, frame, NTSC 
and PAL (with video trigger option). 

Format - YT and XY (and XYZ and dual XY in 
DPO operation). 

Type - 7 in. diagonal, NuColor™ liquid crystal 
full color shutter display, 256 color levels 
(TDS 700D); 7 in. diagonal, magnetic deflec- 
tion, horizontal raster-scan monitor with P4 
white phosphor (TDS 500D). 

Resolution - 640 horizontal by 480 vertical 
displayed pixels (VGA). 

COMPUTER INTERFACE 
GPIB (IEEE-488.2) Programmability - Full 
talk/listen modes. Control of all modes, set- 
tings, and measurements. 

HARDCOPY 

Printer - Phaser 740N/740P, HP Thinkjet, 
DeskJet, LaserJet, Epson, Interleaf, PostScript, 
TIFF, PCX, BMP, DPU41 1/412, RLE. 

Plotter - HPGL 

Data - MathCad, spreadsheet formats. 
Interface - GPIB standard. 

Hardcopy Interface (optional on TDS 
500D) - Centronics and RS-232 (talk only). 

STORAGE 

Non-volatile Waveform Storage - 4 full 50 K 
records (Opt IM or 2M: 4 full 130 K records, 

2 full 250 K records, or 1 compressed 500 K 
record) (TDS 794D, TDS 784D, TDS 754D, 

TDS 580D, TDS 540D); 2 full 50 K records 
(Opt IM or 2M: 2 full 130 K records or 1 full 
250 K record) (TDS 724D, TDS 520D). 
Non-volatile storage for setups - 10 front 
panel setups. 



72 OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 



Digital Phosphor Oscilloscopes 

TDS 500D • TDS 700D 



Floppy Disk Drive - Store reference wave- 
forms, setups, and image files on 3.5 in. 1.44 MB 
or 720 K DOS-format floppy disk. 

Iomega Zip and Zip Plus Drive 
Compatible - Compatible for waveform and 
front panel setup file transfer to Iomega Zip 
and Zip Plus Drives. 

POWER REQUIREMENTS 

Line Voltage Range - 100 to 240 V RMS. 

Line Frequency - 45 to 440 Hz. 

Power Consumption - 350 W max. 

ENVIRONMENTAL AND SAFETY 
Temperature - 

Operating: +4 to +50°C (floppy not used), +10 
to +50®C (floppy in use). 

Nonoperating: -22 to +60°C. 

Humidity - 

Operating: To 80% RH at < 32®C. Derates to 
30% RH at +45®C. 

Nonoperating: To 90% RH at < 40®C. Derates 
to 30% RH at +60°C. 

Altitude - 

Operating: 15,000 ft. (hard disk not used), 
10,000 ft. (hard disk in use). 

Nonoperating: 40,000 ft. 

Electromagnetic Compatibility - UL1244. 
Safety - UL3111-1, CSAIOIO.I, EN61010-1, 
IEC61010-1. 

Physical Characteristics 



Dimensions 


mm 


in. 


Height with feet 


193 


7.6 


Height without feet 


178 


7 


Width with handle 


445 


17.5 


Depth with front 
cover installed 


434 


17.1 


Weight 




lbs. 


Net approximately 


14.1 


31 


Shipping Weight 
approximately 


25.4 


56 




COMMUNICATION SIGNAL ANALYZER 
PACKAGE APPLICATIONS 

► Advanced triggering, including 
triggering for AMI, CMI and NRZ 
communication signals 

► Automatic measurements with meas- 
urement statistics including extinc- 
tion ratio and average optical power 

► Waveform histograms on DPO and 
normal waveform acquisitions 

► Custom mask generation on-board 

► Autoset signals to standard masks 

► SONET/SDH and fibre channel 
optical reference receivers 

► Internal standard communication 
signal masks provided for 
compliance testing for over 

50 communication standards 

► Debugging communications designs 

► Mask testing per comm/video 
standards 

► Optical eye pattern testing 
The Tektronix TDS Communication 
Signal Analyzer package gives you the 
most comprehensive oscilloscope solu- 
tions for connecting to, capturing, and 
characterizing optical and electrical sig- 
nals in high-speed communication 
designs. Based on the TDS 500D/700D 
family of Digital Phosphor Oscilloscopes 
(DPOs), the Communication Signal 
Analyzer options and measurement 
accessories tailor the oscilloscopes for 
engineers debugging, characterizing and 
verifying the compliance of communica- 
tion systems to international standards. 
These communications options comple- 
ment tlie Tektronix 11 80 1C Digital 



Sampling Oscilloscope and the CSA 
803C Communication Signal Analyzer, 
which provide bandwidths up to 50 GHz 
and measurement features tailored for 
optical component manufacturing and 
research and development applications. 

CONNECTING TO THE SIGNAL 

Whether the signals are electrical (differ- 
ential or single-ended) or optical, con- 
necting the design to the measurement 
system is no easy matter. A wide selec- 
tion of complementary measurement 
accessories, optimized for use with the 
TDS oscilloscopes, are available to make 
probing convenient and reliable, while 
maintaining high accuracy. 

Electrical Communication 
Adapters such as the AFTDS ease con- 
nection to differential communication 
signals, such as DSl, DS2 and El, by ter- 
minating the signal in 100 Q, 110 ^2 or 
120 Q and adapting various connector 
styles (bantam, Siemens and RJ-11) to the 
oscilloscope’s 50 Q BNC environment. 

The AMT75 75 Q Adapter simplifies 
connection of video and communication 
signals such as DS3 and E3 to the oscil- 
loscope. This adapter supplies a precise 
termination to signals up to 1 GHz. 

Optical-to-electrical Converters allow 
convenient analysis of optical transmis- 
sion signals. The P6701B can be used for 
Fibre Channel signals and the P6703B 
can be used for SONET/SDH signals. 
They provide high gain (1 V/mW) for sig- 
nals up to 1 GHz and as large as 1 mW 
(0 dBm). The P6723 optical logic probe 
converts SONET/SDH signals into PECL 
digital signals suitable for use as triggers. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPES 73 



25.0GS/SET t2.38MAcq$ 



Digital Phosphor Oscilloscopes 

TDS 500D • TDS 700D 



CAPTURING THE SIGNAL 

High Bandwidth and Sample Rates, up 
to 2 GHz and 1 GS/s per channel, 
enable the user to capture the signal 
with high fidelity. Channels can be 
transparently combined to achieve 
higher sample rates, up to 4 GS/s. 

Digital Phosphor Oscilloscopes capture, 
store, display and analyze, in real-time, 
three dimensions of signal information: 
amplitude, time and distribution of 
amplitude over time. The benefit of this 
new third dimension of information is 
an interpretation of the signal dynam- 
ics, including instantaneous changes 
and the frequency of occurrence dis- 
played in the form of quantitative 
intensity information. 

In addition to standeud Advanced 
Trigger modes such as edge, pulse- 
width, logic and optional video trigger, 
these oscilloscopes have trigger modes 
tailored for communication design and 
debug. The optional Comm trigger 
addresses the need to acquire a wide 
variety of Alternate-Mark Inversion 
(AMI), Code-Mark Inversion (CMI) and 
Non-Return to Zero (NRZ) communica- 
tion signals. These trigger modes may 
be selected manually during routine 
troubleshooting, but are automatically 
selected when mask testing is enabled. 

AMI mode triggers on standard AMI sig- 
nals (including DSl, DS3, El, E2, E3 and 
STS-1). “Isolated ones” triggering is avail- 
able on ANSI Tl.102 AMI signals (includ- 
ing DSl and DS3). CMI triggering isolates 
positive or negative one pulses and zero 
pulses in standard CMI signals (including 
STS-3, STMIE, DS4 and E4). NRZ trigger 
selects rising or falling edges, or any of 
eight 3 -Bit serial patterns in NRZ signals 
(including SONET/SDH, Fibre Channel, 
FDDI, 143, 270, 360 and 1485 Mb/s serial 
video signals). The serial trigger mode 
allows identification of data-dependent 
anomalies in eye diagrams. 

Long streams of serial data, up to 4 ms 
at full resolution, can be captured 
with optional long record length (up 
to 8 M points). 




An example of the selection of isolated-one 
AMI trigger mode. 



CHARACTERIZING THE SIGNAL 

Optional Communication Mask 
Testing allows mask compliance testing 
of a wide variety of communication sig- 
nals against industry standards. The 
instruments are set up for mask testing 
by selecting the standard from the user 
interface. This selection sets up the trig- 
ger system and vertical and horizontal 
scaling and displays the appropriate 
mask. A specialized autoset scales and 
offsets the signal to the selected stan- 
dard mask, making mask testing easy 
and repeatable. The standard communi- 
cation masks in the instrument can be 
edited directly on the screen to create 
custom masks, allowing up to 8 regions 
with 50 vertices. 

In addition to the specialized optical 
measurement accessories, the oscillo- 
scopes have nominal internal 4th-order 
Bessel-Thompson filters for diagnostic 
testing of Fibre Channel and 
SONET/SDH signals. Optional internal 
SONET/SDH (Opt. 3C) and Fibre 
Channel (Opt. 4C) optical reference 
receiver filters on channel 1 of the 
products are also available. These refer- 
ence receivers, required for optical 
compliance testing by ANSI FC-PH, 
Bellcore GR-253-Core and ITU-T G.957, 
can be switched in and out at the touch 
of a button. 

Automatic Measurements eliminate the 
need for manually measuring waveform 




A DS-1 isolated-one signal is compared with 
the standard pulse mask, showing a compli- 
ant waveform. 



parameters. Measurements include 
average optical power (in dBm) and 
extinction ratio (expressed as a ratio, in 
% for FDDI and in dB for SONET/SDH 
and Fibre Channel applications). 

Refer to individual product data sheets 
for full information. 

OPTION 2CT® 

Communication Signal Analyzer Package 
Includes: 

AMI, CMI, and NRZ Comm triggers, commu- 
nication mask testing, nominal Bessel- 
Thompson filtering, automatic pass/fail test- 
ing, mask margin testing, inverted masks 
and mask autoset. 

Standards Supported: OCI/STMO, 
0C3/STM1, OC12/STM4, FC133, FC266, 
FC513, FC1063, DSO, DSl, DSl A, DSlC, DS2, 
DS3, DS4NA, El, E2, E3, E4, E5, STMlE, 
STS-1, STS-3, FDDI, Dl, D2, 259M-D, 292M 
video and Ethernet (10 Base-T, 100 Base-TX, 
1000 Base-SX, 1000 Base-LX). 

OPTION 3C*7 

Fibre Channel Optical Reference Receiver 
Includes: 

P6701 B and reference receiver calibration. 

Standards Supported: FC133, FC266, 
FC531*^and FC1063« 



74 OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 








Digital Phosphor Oscilloscopes 

TDS 500D • TDS 700D 



OPTION 4C*^ 

SONET/SDH Optical Reference Receiver 
Includes: 

P6703B and reference receiver calibration. 

Standards Supported: OCI/STMO, 
OC3/STM1 and OC12/STM4*! 

Available on TDS 784D, TDS 754D and 
TDS 540D. 

Available on TDS 784D and TDS 580D only. 
Frequency response controlled to 1.5 * bit rate. 
TDS 794D does not provide nominal Bessel- 
Thompson filtering. 

Not compatible with TDS 794D. 

OPTION 1M 
Record Length: 

TDS 794D, TDS 784D, TDS 754D, TDS 580D, 
TDS 540D: 500 K maximum. 

TDS 724D, TDS 520D: 250 K maximum. 

OPTION 2M 

Record Length 2 M/Channel: 

TDS 794D, TDS 784D, TDS 754D, TDS 580D, 
TDS 540D: 8 M maximum. 

TDS 724D, TDS 520D: 4 M maximum, 
includes hard disk drive. 




A SONET/SDH (OC-3/STM-1) signal is com- 
pared with the standard mask, showing a 
compliant waveform. 

ACCESSORIES 

High Bandwidth Differential Probes: 

Probe Bandwidth: 

P6248: 1.7 GHz. 

P6247: 1 GHz. 

P6246: 400 MHz. 

AFTDS Differential Signal Adapter: 

Input Impedance (selectable): 100 Q, 110 Q 
or 120 a ±3%. 

Available Connectors: Bantam, Siemens, RJ-11. 

Electrical Standards Supported: DSl, 
DSIA, El, DSIC, DS2. 



AMT75 75 Q. Adapter: 

Input Impedance: 75 Q ± 1.5%. 

Adapter Bandwidth: DC to 1 GHz (typical). 
VSWR (Return Loss): < 1.1:1 (>26 dB, up to 
1 GHz typical). 

Connectors: 75 Q BNC. 

Electrical Standards Supported: E2, E3, 
DS3, STS-1, DS4, E4, STM-1, STS-3, Dl, D2 
and 259M-D, 292M video. 

P6701B Dptical-to-electrical Converter: 
Wavelength Response: 500 to 950 nm. 

Optical Bandwidth: DC to 1 GHz. 

Conversion Gain (at 780 nm): 1 V/mW. 
Standards Supported: Fibre Channel, FDDI. 
P6703B Dptical-to-electrical Converter: 
Wavelength Response: 1100 to 1700 nm. 
Optical Bandwidth: DC to 1.2 GHz. 

Conversion Gain (at 1310 nm): 1 V/mW. 
Standards Supported: SONET/SDH. 

P6723 Dptical Logic Probe: 

Wavelength Response: (1310/1550 nm). 
Standards Supported: SONET/SDH 
< 650 Mb/s. 

OPTICAL ATTENUATORS 

OA5002: 10 pm single-mode. 

OA5012: 50 pm multimode. 

OA5022: 62.5 pm multimode. 

OA5032: 100 pm multimode. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPES 75 




Digital Phosphor Oscilloscopes 

TDS 500D • TDS 700D 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see 



TDS 794D 

Digital Phosphor Oscilloscope. 

TDS 784D 

Digital Phosphor Oscilloscope. 

TDS 754D 

Digital Phosphor Oscilloscope. 

TDS 724D 

Digital Phosphor Oscilloscope. 

TDS 580D 

Digital Phosphor Oscilloscope. 

TDS 540D 

Digital Phosphor Oscilloscope. 

TDS 520D 

Digital Phosphor Oscilloscope. 

INCLUDED ACCESSORIES 
Probes - 4 each P6139A passive probes (TDS 754D, 
TDS 540D), 2 each P6139A (TDS 724D, TDS 520D). 
Documentation - Quick Reference in 9 languages 
(020-2235-00), User Manual (071-0130-00), 

Technical Reference (071-0135-00), Programmer's 
Manual (063-3120-00) in MS-Help format on floppy 
disk, and ANSI, NCSL Z 540-1-1994 (ISO Guide 25) 
calibration certificate. 

Accessories - Front Cover (200-3696-01), US power 
cord (161-0230-01), and accessory pouch (016-1268-00; 
TDS 794D, TDS 784D, TDS 754D, TDS 724D). 

INSTRUMENT OPTIONS 
Opt. 05 - Add video trigger (NTSC, PAL, HDTV, 
FlexFormat’“). (Not available on the TDS 794D) 

Opt. IM - Add 130 K/channel memory length (500 K 
max on TDS 794D, TDS 784D, TDS 754D, TDS 580D, 
TDS 540D) 250 K max (TDS 724D, TDS 520D). 

Opt. 2M - Add 2 M/channel memory length (8 M 
max on TDS 794D, TDS 784D, TDS 754D, TDS 580D, 
TDS 540D; 4 M max on TDS 724D, TDS 520D). 
Includes internal hard disk drive. 

Opt. 13 (TDS 580D, TDS 540D, TDS 520D only) 

- Add RS-232C and Centronics hardcopy interfaces. 
Opt. 2F (TDS 580D, TDS 540D, TDS 520D only) 

- Extended waveform math: FFT, integration and dif- 
ferentiation. 

COMMUNICATION SIGNAL ANALYZER OPTIONS 
Opt. 2C - Communication Signal Analyzer; includes 
comm triggers and communication mask testing. 
Opt. 3C - Short-wavelength (Fibre Channel FC133, 
FC266, FC513, FC1063) Optical Reference Receiver; 
includes P6701 B and system calibration (Not 
Available on the TDS 794D). 

Opt. 4C - Long-wavelength (SONET/SDH OCl/STMO, 
OC3/STM1, OC12/STM4) Optical Reference Receiver; 
includes P6703B and sy^em calibration (Not Available 
on the TDS 794D). 

INSTRUMENT PROBE OPTIONS*^ 

Opt. 31 (TDS 794D only) - Add 1 each P6339A 
buffered passive probe. 

Opt. 33 (TDS 794D, TDS 784D, TDS 580D 
only) - Add 1 each P6158 low capacitance probe. 



Opt. 34 - Add 1 each P6247 differential probe. 

Opt. 35 (TDS 754D, TDS 724D, TDS 540D, 

TDS 520D only) - Add 1 each P6243 1 GHz active 
probe. 

Opt 36 (TDS 784D, TDS 754D, TDS 724D, 

TDS 580D, TDS 540D, TDS 520D only) - Add 

1 each P6139A passive probe. (4 standard on TDS 754D, 
TDS 540D, 2 standard on TDS 724D, TDS 520D). 

Opt. 37 (TDS 784D and TDS 580D only) - Add 

1 each P6245 .5 GHz active probe. 

Opt. 38 (TDS 794D only) - Add 1 each P6249 4 GHz 
active probe. 

Opt. 39 (TDS 794D only) - Add 1 each P6248 
1.7 GHz differential probe. 

INSTRUMENT APPLICATIONS MEASUREMENT 
SOFTWARE 

Requires TDS 500/600/700 Opt. HD or 2M. 

TDSPRT1 - Printing Utility. 

TDSDDM1 - Disk drive measurement package. 
TDSPWR1 - Power measurement package. 

TDSJIT1 - Jitter analysis measurement package. 
TDSPSM1 - Processor specifications measurement 
package. 

TDSCEM1 - Communications eye-diagram 
measurement package. 

TDSPSM1 - Processor specifications measurement. 
TDSCEM1 - Communications eye-diagram 
measurement. 

WSTRO - WaveStar™ software for Oscilloscopes, 
Windows 95/98/NT application for waveform capture, 
analysis, documentation and control from your PC. 
WSTROU - Upgrade from WSTR31 to WSTRO. 
WSTR31 - WaveStar™ software for Windows 3.1. 
LVWIN95 - LabVIEW" for Windows 95. 

LVWCVI95 - LabWindows/CVI for Windows 95. 
S3FT400 - WaveWriter™ AWG and waveform creation 
software. 

INTERNATIONAL POWER PLUGS 

Opt. A1 - European power cord (220 V, 50 Hz). 

Opt. A2 - UK power cord (240 V, 50 Hz). 

Opt. A3 - Australian power cord (240 V, 50 Hz). 
Opt A4 - North American power cord (240 V, 60 Hz). 
Opt. A5 - Swiss power cord (220 V, 50 Hz). 

See page 619 for description. 

OPTIONAL ACCESSORIES 
Opt. IK - Add K420 scope cart. 

Opt. 1R - Rackmount kit. 

Opt. LI - Substitute French user manual for English 
user manual. 

Opt. L3 - Substitute German user manual for 
English user manual. 

Opt. L5 - Substitute Japanese user manual for 
English user manual. 

Opt. L9 - Substitute Korean user manual for English 
user manual. 



the price list in the back of this catalog. 

RECOMMENDED PROBES 
ADA400A - Differential Preamplifier. 

AM503S - DC/AC Current Measurement System. 
AFTDS - Electrical communication differential signal 
adapter. 

AMT75 - 1 GHz electrical communication 75 Q 
adapter. 

P5100 - 2.5 kV High-voltage probe. 

P5205 - 1.3 kV High-voltage 100 MHz differential 
probe. 

P5210 - 5.6 kV High-voltage 50MHz differential 
probe. 

P6139A - 500 MHz passive lOX voltage probe. 
P6205 - 750 MHz active voltage probe. 

P6243 - 1 GHz active voltage probe. 

P6245 - 1.5 GHz active voltage probe. 

P6249 - 4 GHz active voltage probe. 

P6158 - 3 GHz low capacitance voltage probe. 
P6339A - 500 MHz buffered passive voltage probe 
(TDS 794D only). 

P6246 - 400 MHz differential probe. 

P6247 - 1 GHz differential probe. 

P6248 - 1.7 GHz differential probe. 

P6563A - SMD passive voltage probes. 

P6701B - Short-wavelength (500-950 nm) optical- 
to-electrical converter. 

P6703B - Long-wavelength (1100-1700 nm) optical- 
to-electrlcal converter. 

P6723 - Optical logic probe (1310/1550 nm). 
TCP202 - DC to 50 MHz current probe. 

RECOMMENDED ACCESSORIES 

Also see page 56. 

Service Manual - TDS 500D/600B/700D. Order 
071-0136-00. 

GPIB - LAN Adapter - Order AD007. 

Transit Case - Order 016-1135-00. 

Scope Cart - Order K420. 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of Calibration Services. 

Opt. D1 - Cal Data Report. 

Opt. D3 - Test Data (requires Opt. C3). 

See page 615 for further information. 

Java™ is a registered trademark of Sun Microsystems 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

C€ 

jg ISO 9001 

Tektronix measurement products are manufactured 
in ISO registered facilities. 

GPIB 

IECE-488 

Product(s) complies with IEEE Standard 488.1-1987, 
and with Tektronix Standard Codes and Formats. 



76 OSCILLOSCOPES 



www.tektronix.ioni/Measurement/scopes/ 





Digital Storage Oscilloscopes 

New TDS 694C • TDS 684C • TDS 680C • TDS 654C 




For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call; 
1-503-627-1916, 
inside the U.S. call; 
1-800-426-2200. 

C€ 

ISO 9001 

Tektronix measurement 
products are manufactured in 
ISO registered facilities. 




Product(s) complies with IEEE 
Standard 488.2-1987, 
and with Tektronix Standard 
Codes and Formats. 



Features - Benefits Applications 



3 GHz, 1 GHz and 500 MHz 
Bandwidths to Work with the Fastest 
Signals in Toda/s Digital Designs 

10 GS/s and 5 GS/s Sample Rates 
on all Channels Simultaneously for 
Full Bandwidth Single-shot Capture 

Histograms and Measurement 
Statistics to More Fully Characterize 
Design Performance 

Support for Java Applications 
Packages 

Hard Disk Drive Storage (option) 

Support for Iomega parallel port 
Zip™ drives 

Waveform Math and Advanced 
Waveform DSP 

Fully Automated Measurement 
System 

Waveform Pass/Fail Template Testing 

Color Display (TDS 654C, TDS 
684C, TDS 694C) 

RS-232, Centronics, and GPIB 
Interfaces Included Standard 

Record Length to 1 20,000 
Points/channel* 

Timebase Accuracy to 10 ppm. 

Time Interval Measurement 
Accuracy to ±15 ps (TDS 694C) 

Trigger Jitter 8 ps RMS (Typical) 

1% Vertical Accuracy (TDS 694C) 

100 ps Peak Detect (TDS 694C only) 



Validation and Characterization of 
High Speed Digital Designs 
Verify Simulation Performance 
with Real Measurements 
Ensure that Desired Design 
Margins Exist 

Jitter Measurements on High-speed 
Data, Phase-locked Loops and 
Spread-spectrum Clock Circuits 
Capture Glitches, Cross-talk, 
Setup/hold Violations 

Telecommunications/Data 
Communications Design 
Characterize Rise Times, Overshoot, 
Channel to Channel Timing 
Verify and Test High Speed Serial 
Data Streams 

High Energy Physics 
Transient Event Capture 



* TDS 694C with long record length 
option (1 M) only. 15,000 points/channel 
maximum on TDS 684C/680C/654C. 



Whether you are working on next generation 
microprocessor designs, high-speed data commu- 
nications equipment, or in high-energy physics 
research, the TDS 694C captures your fastest sig- 



nals with the best fidelity and resolution avail- 
able. Its 3 GHz bandwidth preserves your wave- 
form’s fast rising edges and accurately shows sig- 
nal details. With 10 GS/s digitizing rate simulta- 



w¥vw.tektronix.com/Measureraeiit/scopes/ 



OSCILLOSCOPES 77 






Digital Storage Oscilloscopes 

NEW TDS 694C • TDS 684C • TDS 680C • TDS 654C 



neously on all four channels and a high- 
stability timebase, the TDS 694C makes 
your critical timing measurements with 
the highest resolution and accuracy 
- even channel-to-channel measure- 
ments made in a single acquisition. 

The TDS 600C oscilloscopes incorporate 
all the advanced trigger features you 
expect in a high performance oscillo- 
scope: triggering on Glitches, Slew Rate 
violations, Setup and Hold Time viola- 
tions, Time Outs, Logic Patterns and 
States on four channels. For applications 
where sophisticated multi-channel 
debugging is required, the TDS 694C can 



be configured for cross triggering with a 
Tektronix TLA 700 Logic Analyzer. 

The TDS 600C oscilloscopes give you 
the total solution to your digital design 
characterization and debugging needs. 
Now you have the tool you need to ver- 
ify design margins, characterize setup 
and hold times, and measure clock-to- 
data skew on the fastest digital designs. 

The TDS 694C's companion probe, the 
P6249, offers small size to reliably con- 
tact your high-density boards with their 
fine-pitch, hard to reach components. 
The P6249 has short ground connection 
to give the maximum system bandwidth 



and preserve the details of your signals. 

The TDS 600C offers 29 automatic meas- 
urements, with measurement statistics, to 
make your design verification and char- 
acterization job much faster and easier. 
Available Java-based apphcation pack- 
ages for Jitter Analysis, Disk Drive meas- 
urements and Processor Specification 
measurements provide customized meas- 
urements and analysis capability. The 
TDS 600C gives you the performance and 
featmes you need to get your job done 
faster and more thoroughly. 



Characteristics 



TDS 654C TPS 680C TPS 684C TPS 694C 



Total Channels 


4 


2 + 2 


4 


4 


Sample Rate (all channels simultaneously) 


5 GS/s 


5 GS/s 


5 GS/s 


10 GS/s 


Real-time Bandwidth 


500 MHz 


1 GHz 


1 GHz 


3 GHz 


Maximum Record Length per Channel 


15,000 pts 


15,000 pts 


15,000 pts 


120,000 pts 


Vertical Resolution 


1 mV/div- 10 V/div 


1 mV/div - 10 V/div 


1 mV/div - 10 V/div 


10 mV/div - 1 V/div 


Delta Time Measurement Accuracy 


<50 ps @ 5 CS/s 


<50 ps @ 5 GS/s 


<50 ps @ 5 GS/s 


15 ps @ 10 GS/s 


Advanced Waveform DSP/Math 


Std. 


Std. 


Std. 


Std. 


Histograms and Measurement Statistics 


Std. 


Std. 


Std. 


Std. 


standard Probes 


4 P6243 


None 


None 


None 


Display Type 


7 in. NuColor™ Display 


7 in. monochrome 


7 in. NuColor™ Display 


7 in. NuColor™ Display 


Floppy Drive 


Std. 


Std. 


Std. 


Std. 


.......xr.i — — — - 

GPIB, R5-232 & Centronics 


Std. 


Std. 


Std. 


Std. 


VGA Output 


Std. Color 


Std. Mono 


Std. Color 


std. Color 


Hard Disk Drive 


opt 


Opt 


Opt 


Opt 



TIME BASE SYSTEM 
Time Bases - Main and delayed. 

Time/div Range - 200 ps/div to 10 s/div. 
except TDS 694C: 100 ps^iv to 10 s/div. 
Time Base Accuracy - Over any interval 
>1 ms 100 ppm. Except TDS 694C: Over any 
interval > 1 ms ± 10 ppm. 

Time Interval Measurement Accuracy - 
TDS 654C/680C/684C: ±[(0.2/sample rate) 

+ (100 ppm X |Reading|)l single shot. 

(« 50 ps @ 5 GS/s) 

TDS 694C: ±[(0.1 5/sample rate) + (10 ppm x 
|Reading|)l single shot. (« 15 ps @ 10 GS/s) 

Record Length per Channel - 

500 to 15,000 pts. except TDS 694C: 500 to 
30,000 pts. (optional: 120,000 pts.) 

Trigger Jitter - 8 ps RMS (typical). 

Pre-Trigger Position - 
0% to 100% of record. 

Channel to Channel Deskew Range - 

±25 ns. 



VERTICAL SYSTEM 

Vertical Resolution - 8-Bits (> 11 -Bits with 

averaging). 

Vertical Sensitivity - 1 mV/div to 10 V/div. 
Except TDS 694C: 10 mV/div to 1 V/div. 
Maximum Input Voltage - 300 V CAT II; 

±400 V peak. Derate at 20 dB/decade above 
1 MHz. Except TDS 694C: 5 V RMS. 

DC Gain Accuracy - ±1.5%. Except 
TDS 694C: ±1.0%. 

Position Range - ±5 divs. 

Offset - ±1 V from 1 to 99.5 mV/div, ±10 V 
from 100 mV to 995 mV/div, ±100 V from 1 V 
to 10 V/div. 

Except TDS 694C: ±0.5 V from 10 to 50 mV/div, 
±0.25 V from 50.5 to 100 mV/div, ±5 V from 
101 mV to 500 mV/div, ±2.5 V from 505 mV to 
1 V/div. 

Bandwidth Selections - 20 MHz, 250 MHz, 
and Full. Except TDS 694C: Full only. 

Input Impedance Selections - 1 MQ in par- 
allel with 10 pF, or 50 Q (AC and DC coupling). 



Except TDS 694C: 50 Q (DC coupled). 

Input Coupling - AC, DC or GND. 

Except TDS 694C: DC or GND. 

AC Coupled Low Frequency Limit (Except 
TDS 694C) - <10 Hz when AC, 1 MH coupled. 
<200 kHz when AC, 50 Q coupled. 

ACQUISITION MODES 
Peak Detect - High frequency and random 
glitch capture. Captures glitches of 1 ns using 
acquisition hardware at all real-time sampling 
rates. TDS 694C captures glitches of 100 ps. 
Sample - Sample data only. 

Envelope - Max/min values acquired over 
one or more acquisitions. 

Average - Waveform data from 2 to 10,000 
waveforms (selectable) is averaged. 

Single Sequence - Use RUN/STOP button to 
capture a single triggered acquisition at a time, 
which may be automatically saved to NVRAM 
with AutoSave. 



78 OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 




Digital Storage Oscilloscopes 

NEW TDS 694C • TDS 684C • TDS 680C • TDS 654C 



TRIGGERING SYSTEM 

TRIGGER TYPES 
EDGE (Main and Delayed) - 

Conventional level-driven trigger. Positive or 
negative slope on any channel or rear panel 
auxiliary input. Coupling selections: DC, AC, 
noise reject, HF reject, LF reject. 

LOGIC (Main) - 

PATTERN: Specifies a logical combination (AND, 
OR, NAND, NOR) of the four input channels 
(high, low, don't care). Trigger when pattern 
stays true or false for a specified time. 

STATE: Any logical pattern of channels 1, 2, and 3 
(AUXl on TDS 680C) plus a clock edge on chan- 
nel 4 (AUX2 on TDS 680C). Triggerable on rising 
or falling clock edge. 

SETUP/HOLD: Trigger on violations of both 
setup time and hold time between clock and 
data which are on two Input channels. 

PULSE (Main) - 

GLITCH: Trigger on or reject glitches of positive, 
negative, or either polarity. Minimum glitch 
width Is 1.0 ns with 200 ps resolution. 

RUNT: Trigger on a pulse that crosses one 
threshold but fails to cross a second threshold 
before crossing the first again. 

WIDTH: Trigger on width of positive or negative 
pulse either within or out of selectable time 
limits (1 ns to 1 s). 

SLEW RATE: Trigger on pulse edge rates that 
are either faster or slower than a set rate. 

Edges can be rising, falling, or either. 

TIMEOUT: Trigger on an event which remains 
high, low, or either, for a specified time peri- 
od, selectable from 1 ns to 1 s, with 200 ps 
resolution. 

TLA Cross Trigger (TDS 694C only) - Utilize 
a TLA 700 logic analyzer to detect a multi- 
channel event, then trigger the TDS 694C. The 
trigger points on the TLA and TDS will be 
aligned In time. 

VIDEO (Optional; Not Available in 
TDS 694C) - Trigger on a particular line of 
individual, odd/even, or all fields. Trigger on a 
specific pixel of a line by using the video trig- 
ger with delay by events. Choose positive or 
negative horizontal sync polarity. 

525/NTSC: Choose monochrome or color 
(studio-quality NTSC) sync formats. 625/PAL: 
Choose color or monochrome (studio-quality 
PAL) sync formats. HDTV: Choose from 
1125/60, 1050/60, 1250/50, and 787.5/60 HDTV 
formats. 

Trigger Bandwidth (Edge Type) - 

3 GHz (TDS 694C), 1 GHz (TDS 684C, 

TDS 680C), 500 MHz (TDS 654C). 



Main Trigger Modes - Auto, Normal, Single. 
Delayed Trigger - Delay by time, events, or 
events and time. 

Delay by Time Range - 16 ns to 250 s. 

Delay by Events Range - 2 to 9,999,999 
events. 

External Trigger Input - Input Impedance: 
>1.5 Max. Input Voltage: ±20 V 
(DC + peak AC). 

DISPLAY CHARAaERISTICS 
Waveform Style - Dots, vectors, variable per- 
sistence from 32 ms to 10 s, infinite persistence, 
and Intensified samples. 

Color (TDS 694C TDS 684C, TDS 654C) - 
Standard palettes and user-definable color for 
waveforms, text, graticules, and cursors. 
Measurement text and cursor colors matched 
to waveform. Waveform collision areas high- 
lighted with different color. Statistical waveform 
distribution shown with color grading through 
variable persistence. 

Color Grading (TDS 694C, TDS 684C, 

TDS 654C) - With variable persistence select- 
ed, historical timing information is represented 
by temperature or spectral color scheme (or 
gray scale on TDS 680C). 

Graticules - Full, grid, cross-hair, frame, and 
NTSC and PAL (with video trigger option). 
Format - YT and XY. 

Resolution - 640 horizontal by 480 vertical 
displayed pixels (VGA). 

Color CRT Monitor (TDS 654C/684C/694C) - 

7 in. diagonal NuColor'^ liquid crystal full-color 
shutter, 256 levels. 

Monochrome CRT Monitor (TDS 680C) - 

7 in. diagonal, magnetic deflection. Horizontal 
raster-scan. P4 white phosphor. 

MEASUREMENT SYSTEM 
Automatic Waveform Measurements - 

Period, frequency, + width, - width, rise time, fall 
time, + duty cycle, - duty cycle, delay, phase, 
burst width, high, low, max, min, peak to peak, 
amplitude, + overshoot - overshoot mean, 
cycle mean, RMS, ^cle RMS, area, cycle area, 
extinction ratio (ratio, dB, %), and mean optical 
power. Continuous update of up to four meas- 
urements on any combination of waveforms. 
Measurement Statistics - Display minimum 
and maximum or mean and standard devia- 
tion on any displayed single-waveform meas- 
urements. 

Thresholds - Settable In percentage or voltage. 
Gating - Any region of the waveform may be 
isolated for measurement using vertical bars. 



Snapshot - Performs all measurements on 
any one waveform showing results from one 
instant in time. 

Cursor Measurements - Absolute, 

Delta: Volts, Time, Frequency, and NTSC IRE 
and line number (with video trigger option). 
Cursor Types - Horizontal bars (volts), verti- 
cal bars (time); operated independently or in 
tracking mode. 

Histogram Measurements - Mean, median, 
standard deviation, hits, waveform count, 
peak hits, peak to peak, % mean ± 1, 2, and 3 
standard deviations. 

WAVEFORM PROCESSING 
Waveform Functions - Interpolation (sin(x)/x 
or linear). Average, Envelope, Auto Setup. 
Advanced Waveform Functions - FFT, 
Integration, Differentiation, Waveform (math or 
acquired) Limit Testing. 

Arithmetic Operators - Add, Subtract, 
Multiply, Divide, Invert. 

Autoset - Single-button, automatic setup on 
selected input signal for vertical, horizontal, 
and trigger systems. 

Waveform Limit Testing - Compares incom- 
ing or math waveform to a reference wave- 
form's upper and lower limits. 

Waveform Histograms - Both vertical and 
horizontal histograms, with periodically updat- 
ed measurements, allow statistical distributions 
to be analyzed over any region of the signal. 

ZOOM CHARAaERISTICS 

The zoom feature allows waveforms to be 
expanded or compressed In both vertical and 
horizontal axes. Allows precise comparison and 
study of fine waveform detail without affecting 
ongoing acquisitions. When used with Average 
acquisition modes. Zoom provides an effective 
vertical dynamic range of 1000 divisions or 100 
screens. 

Dual Window Zoom - Dual graticules simul- 
taneously show selected and zoomed wave- 
forms. Up to two zoom boxes show areas on 
the selected trace that are being magnified, 
and the two magnified areas can be over- 
lapped for quick comparison. Color of zoomed 
trace matches selected trace. 

HARDCOPY 

Printer - HP Thinkjet, Deskjet, Laserjet, 

Epson, Interleaf, PostScript, TIFF, PCX, BMP, 
DPU41 1/412, RLE. 

Plotter - HPGL. 

Data - MathCad, spreadsheet formats. 
Hardcopy Interface - Centronics and RS-232 
(talk only). 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPES 79 



Digital Storage Oscilloscopes 

NEW TDS 694C • TDS 684C • TDS 680C • TDS 654C 



DATA STORAGE 

Standard - Internal MS-DOS 1.44 MB floppy, 
external Iomega Zip"“ drive support. 

Optional - Internal hard disk drive. 

Non-volatile Storage for Setups - 10 front 
panel setups. 

Floppy Disk Drive - Store reference wave- 
forms, setups, and Image files on 3.5 In. 

1.44 MB or 720 K DOS-format floppy disk. 
Iomega Zip"^ Drive Compatible - 
Compatible for waveform, hardcopy, and front 
panel setup file transfer to Iomega Zip™, 
ZipPlus™, and Zip250™ Drive. 

POWER REQUIREMENTS 

Line Voltage Range - 90 to 250 V RMS. 

Line Frequency - 45 to 440 Hz. 

Power Consumption - 300 W max. 

(TDS 654C/680C/684C). 

450 W max. (TDS 694C). 



ENVIRONMENTAL AND SAFETY 
Temperature - 

Operating; +4°C to +45°C (floppy not used), 
+10®C to +45®C (floppy in use). 

Nonoperating: -22°C to +60®C. 

TDS 694C: Operating: +5°C to +40°C (floppy 
not used), +10®C to +40°C (floppy in use). 
Nonoperating: -22°C to +60®C. 

Humidity - Operating: 20% to 80% RH at or 
below +32°C. 

Altitude - Operating: 15,000 ft. (hard disk not 
used), 10,000 ft. (hard disk in use). Non-oper- 
ating: 40,000 ft. 

Electromagnetic Compatibility - UL1244. 
Safety - UL3111-1, CSAIOIO.I, EN61010-1, 
IEC61010-1. 



Physical Characteristi 


ICS 


Dimensions 


mm 


in. 


Height with feet 


193 


7.6 


Height without feet 


178 


7 


Width with handle 


445 


17.5 


Depth with front cover installed 


434 


17.1 


Weight 


H . 


lbs. 


Net approximately 


14.1 


31 


Shipping Weight approximately 


24.0 


53 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of Calibration Services. 



TDS 694C 

Four-channel Color 3 GHz, 10 GS/s Per Channel, 
Digital Storage Oscilloscope. 

Includes: User Manual (071 -0473-00), Quick 
Reference Guide (071-2313-00), Programmer's 
Manual in MS-Help format on floppy disk 
(063-3060-00), Technical Reference (Performance 
Verification) Manual (071-0496-00), Probe Deskew 
Fixture (679-4809-00), Footswitch and Adapter 
(260-1189-02 and 013-0312-00), Front Cover (200- 
3696-00), North American Power Cord (161-0230- 
01), Accessory Pouch (016-1268-00). 

TDS 684C 

Four-channel Color 1 GHz, 5 GS/s Per Channel 
Digital Storage Oscilloscope. 

TDS 680C 

Two-channel Monochrome 1 GHz, 5 GS/s Per 
Channel Digital Storage Oscilloscope. 

TDS 654C 

Four-channel Color 500 MHz, 5 GS/s Per Channel 
Digital Storage Oscilloscope. Includes: Four P6243 
FET Probes. 

TDS 654C/TDS 680C/TDS 684C Include: User 
Manual (070-0130-00), User Supplement (071-0273- 
00), Quick Reference Guide (020-2235-00), 
Programmer's Manual in MS-Help format on floppy 
disk (063-3120-00), Technical Reference Manual (071- 
0272-00), Front Cover (200-3696-00), North 
American Power Cord (161-0230-01), Accessory 
Pouch (016-1268-00) (Except TDS 680C). 



OPTIONS 

Opt. 05 - Video Trigger, NTSC, PAL, HDTV, 
FlexFormar. (Except TDS 694C) 

Opt. IK - Model K420 Instrument Cart. 

Opt. IM - 120 k Record Length. (TDS 694C only) 
Opt. 1R - Rackmount Kit. 

Opt. 31 - Add 1 ea. P6339A Buffered Passive Probe. 
(TDS 694C only) 

Opt. 33 - Add 1 ea. P6158 Low Capacitance Probe. 
(Except TDS 654C) 

Opt. 34 - Add 1 ea. P6247 Differential Probe. 
(Except TDS 694C) 

Opt. 35 - Add 1 ea. P6243 Active Probe. (TDS 654C 
Only) 

Opt. 36 - Add 1 ea. P6139A Passive Probe. (Except 
TDS 694C) 

Opt. 37 - Add 1 ea. P6245 Active Probe. (Except 
TDS 654C) 

Opt. 38 - Add 1 ea. P6249 4 GHz Active Probe. 
(TDS 694C only) 

Opt. 39 - Add 1 ea. P6248 1.7 GHz Differential 
Probe. (TDS 694C only) 

Opt. HD - Internal Hard Disk Drive. 



Opt. D1 - Calibration Data Report. 

Opt. D3 - Test Data (requires Opt. C3). 

INTERNATIONAL POWER PLUGS 
Opt. A1, A2, A3, A5. 

See page 619 for description. 

SOFTWARE 

TDS JAVA APPLICATIONS 

TDSJIT1 - Jitter and timing analysis application. 

TDSDDM1 - Hard disk drive measurement 

application. 

TDSPSM1 - Processor specifications measurement 
application. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, Inside the U.S. call: 1-800-426-2200. 

CC 

^1509001 

Tektronix measurement products are manufactured 
in ISO registered facilities. 



Product(s) complies with IEEE Standard 488.2-1987, 
and with Tektronix Standard Codes and Formats. 



80 OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 




Jitter Analysis Software 

NEW TDSJIT1 




Jitter Analysis Software 

► Your TDS 500/600/700 Series oscil- 
loscope can perform jitter analysis 
without external equipment 

► Installs inside the TDS oscillo- 
scope requiring no external GPIB, 
RS-232 or PC 

► Provided on floppy disk for easy 
customer installation 

► Uses familiar, user-friendly TDS 
user interface 

► Characterize jitter on single inputs, 
differential inputs and chaimel to 
channel waveforms 

► Define timing analysis features by 
slope, level and hysteresis 

► Single-shot analysis on user-selec- 
table record lengths 

► Measure jitter timing parameters 
over contiguous clock cycles 

► Profile all jitter timing measurements 
vs. cycle 

► Comprehensive statistics and cus- 
tomized histograms on all profile 
parameters 

► Measurements include: cycle-cycle, 
N-cycle, skew, period, width, and 
duty cycle 



► Period time-stamps can be exported 
for external analysis 

► Typical TDS 694C single-shot meas- 
urement repeatability: 3 ps RMS*’ 

► Peak TDS 694C single-shot delta 
time accuracy: 15.1 ps*- 

APPLICATIONS 

► Characterize the timing performance 
of your semiconductor systems 

► Determine the timing margins in 
your digital designs 

► Use the channel to channel measure- 
ments to characterize spread spec- 
trum clock PLLs 

*^TDS 694C single-shot measurement repeata- 
bility = 0.03/(sampIe rate). This gives 3 ps at 
10 GS/s. 

*^TDS 694C single-shot delta time accuracy = 
0.15/(sample rate) +10 ppm * I measure- 
ment \ . This gives 15.1 ps accuracy for a 
10 ns (100 MHz) measurement at 10 GS/s. 

USER-INSTALLED, OSCILLOSCOPE RES- 
IDENT JITTER ANALYSIS PACKAGE 

Electronic design engineers in semicon- 
ductor industries develop ICs with high 
clock speeds and reduced timing mar- 
gins. As clock frequencies in the indus- 
try continue to increase, timing margins 
become more critical. Sophisticated 
techniques are required to properly 
characterize the placement of these 
clock edges. Customers in the computer 
industry need to ensure that the timing 
margins in their designs are not violat- 
ed because of excessive jitter. 



The TDS 500D/600C/700D oscilloscopes 
have superb jitter analysis capabilities 
on non-contiguous clock cycles ^with 
their histogram and statistics capabili- 
ties. The Tektronix TDSJITl Jitter 
Analysis Software will extend that capa- 
bility by making jitter measurements on 
contiguous clock cycles from single-shot 
acquisitions. TDSJITl provides many 
key timing parameter measurements. 
These are specifically designed to meet 
the jitter measurement needs of today’s 
high speed digital designers. 
Measurements can be made on differen- 
tial signals and between two separate 
input signals. Profile plots quickly show 
how various timing parameters change 
over time. Comprehensive statistics and 
histograms of timing parameters 
enhance the powerful analysis capabili- 
ties of TDSJITl. 

TDSJITl Jitter Analysis Software is a 
software package from Tektronix that 
delivers industry standard jitter and tim- 
ing analysis capabilities. It comes on 
floppy disks, is easily installed in a TDS 
oscilloscope, and doesn’t require any 
external processing or connections. After 
installation, the application is accessible 
from the oscilloscope front panel. 

TEKTRONIX OSCILLOSCOPES 
SUPPORTED 

TDS 500D, TDS 600C, TDS 700D series 
oscilloscopes with Option HD. 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 



TDS IIT1 

Jitter Analysis Software for TDS 500/600/700 
osdiloscopes. 

Includes: Software on 3.5-in. Disk, Manual. 
Note: Requires TDS 500/600/700 Opt. HD or 2M. 



TDSJITl RECOMMENDED ACCESSORIES 
High-bandwidth Differential Probe - P6248 
1.7 GHz Differential Probe. 

High-bandwidth Active Probe - P6249 4 GHz 
Active Probe. 

Data Generator - DG2040 Data Generator. 
Arbitrary Waveform Generator - AWG 610 

Programmable Arbitrary Waveform Generator. 



C€ 

Tektronix measurement products are manufactured 
in ISO registered facilities. 



www.tektronix.coin/Measureineiit/scopes/ 



OSCILLOSCOPES 81 





Communications Eye-diagram Measurements Software 

NEW TDSCEM1 




Eye Diagram Measurement 
Software 

► Perform automatic eye diagram 
measurements of: % crossing, eye 
height, eye width, quality factor, 
extinction ratio and jitter 

► Provides more in-depth understanding 
of your communication signal beyond 
qualitative pass/fail mask testing 

► Adds additional capability to your 
TDS communications analyzer pack- 
age by enabling your TDS 500/700 
Series oscilloscope to perform auto- 
mated eye diagram measurements 

► Optical standards measured include: 

— SONET/SDH: OCl/STMO, 
OC3/STM1, OC12/STM4 

— Fibre channel: FC133, FC266, 

FC531, FC1063 

— Gigabit ethernet: 1.25 Gb/s 

► With the unique autoset to standard 
mask capability, you do not need to 
set up the vertical, horizontal, trigger 
or filter controls 

► Set the population size for the 
statistics measurements 



► Log the measurement results to a file 
for future analysis 

► GPIB control of measurements for 
use in ATE applications 

► Installs inside the TDS oscilloscope 
requiring no external GPIB, RS-232 
or PC 

APPLICATIONS 

► Characterize the quality of your opti- 
cal communications signals with 
accurate eye diagram analysis 

USER-INSTALLED, OSCILLOSCOPE 
RESIDENT EYE DIAGRAM 
MEASUREMENT PACKAGE 

Option 2C, the Tektronix TDS 
Communication Signal Analyzer pack- 
age, gives you the most comprehensive 
oscilloscope solutions for connecting to, 
capturing, and characterizing optical 
and electrical signals in high-speed 
commmiication designs. Based on the 
TDS 500D/700D family of Digital 
Phosphor Oscilloscopes (DPOs), Option 
2C and various measurement acces- 
sories tailor the oscilloscope for engi- 
neers debugging, characterizing, and 
verifying tlie compliance of communica- 
tion systems to international standards. 

TDSCEMl adds additional capability to 
Option 2C by allowing communication 
customers to perform quantitative 
measurements on their eye diagrams in 
addition to qualitative mask testing. 
TDSCEMl provides an extensive suite 
of additional measurements to support 
analysis and trouble-shooting beyond 
simple pass-fail testing. 



Customers who will benefit from 
TDSCEMl are electronic design engi- 
neers working for communication 
equipment manufacturers in the com- 
munications industry who develop 
products with standard communication 
interfaces. These engineers need tools 
to properly characterize their designs 
and verify compliance to industry stan- 
dards. These standards include 
SONET/SDH, Fibre Channel and 
Gigabit Ethernet. Characterization of 
these optical and electrical signals 
include mask testing as well as eye dia- 
gram measurements. 

TDSCEMl comes on a single floppy 
disk, is easily installed in a TDS oscil- 
loscope, and doesn’t require any exter- 
nal processing or connections. After 
installation, the application is accessi- 
ble from the oscilloscope front panel. 

TEKTRONIX OSCILLOSCOPES 
SUPPORTED 

TDS 500D, TDS 700D series oscillo- 
scopes with Communication Signal 
Analyzer Option 2C and a hard disk 
drive (Option HD or Option 2M). 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916. inside the U.S. call: 1-800-426-2200. 



TDSCEMl 

Communications Eye Diagram Measurement 
Software for TDS 500/700 Oscilloscopes. 
Includes: Software on a 3.5-in. Disk, Manual. 
Note: Requires TDS 500/600/700 Opt. HD or 2M, 
and TDS 500/700 Communication Signal Analyzer 
Option 2C, FW v6.4e. 



TDSCEMl RECOMMENDED OPTIONS AND 

ACCESSORIES 

AMT75 - 75 Q Adapter. 

TDS Option 3C - (includes P6701B) Short-wave- 
length Fibre Channel Optical Reference Receiver. 
TDS Option 4C - (includes P6703B) Long-wave- 
length SONET/SDH Optical Reference Receiver. 
P6701B/P6703B - Optical-to-Electrical Converters. 
P6723 - Optical Logic Probe. 
OA5002/OA5012/OA5022/OA5032 - Optical 
Attenuators. 



cc 

^isomi 

Tektronix measurement products are manufactured 
in ISO registered facilities. 



82 OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 





Communications Pulse Measurements Software 

NEW TDSCPM1 




Communications Pulse 
Measurement Software 

► Enhances the Capabilities of Your 
TDS Communications Analyzer 
Package by Enabling Your TDS 
500/700 Series Oscilloscope to 
Perform Automated Parametric 
Measurements on Various Electrical 
Communication Pulse Waveforms 

► Perform Measurements and Pass/Fail 
Testing of: 

- Pulse Amplitude 

- Spectral Power 

- Pulse Imbalance 

- Pulse Symmetry 

- Zero Level 

► Standards Measured Include ANSI 
T1.102 and ITU-T G.703 



► With the Unique Autoset to 
Standard Mask Capability, You Do 
Not Need to Set Up the Vertical, 
Horizontal, Trigger or Filter Controls 

► Log the Measurement Results to a 
File for Future Analysis 

► GPIB Control of Measurements if 
Desired 

► Installs Inside the TDS Oscilloscope 
Requiring no External GPIB, RS-232 
or PC 

► Provided on a Single Floppy Disk for 
Easy Customer Installation 

► Uses Familiar, User-friendly TDS 
User Interface 

APPLICATIONS 

► Characterize the Standards 
Compliance of Electrical 
Communications Signals 

USER-INSTALLED, OSCILLOSCOPE 
RESIDENT COMMUNICATION PULSE 
SIGNAL MEASUREMENT PACKAGE 

Electronic design engineers, working 
for communication equipment manu- 
facturers in the communications indus- 
try, develop products with standard 
communication interfaces. These engi- 
neers need tools to properly character- 
ize their designs and verify compliance 
to industry standards. These standards 
include ANSI Tl. 102-1993 and ITU-T 
G.703. Characterization of these electri- 
cal signals include mask testing as well 
as parametric testing. 



Option 2C, the Tektronix TDS 
Communication Signal Analyzer pack- 
age, gives you the most comprehensive 
oscilloscope solutions for connecting to, 
capturing, and characterizing optical 
and electrical signals in high-speed 
communication designs. Based on the 
TDS 500D/700D family of Digital 
Phosphor Oscilloscopes (DPOs), Option 
2C and various measurement acces- 
sories tailor the oscilloscope for engi- 
neers debugging, characterizing, and 
verifying the compliance of communica- 
tion systems to international standards. 

This capability is further enhanced by 
TDSCPMl which allows electrical com- 
munication customers to perform quan- 
titative measurements on their pulse 
waveforms in addition to mask tests 
provided by the Option 2C capabilities 
and accessories. 

TDSCPMl comes on a single floppy 
disk, is easily installed in a TDS oscil- 
loscope, and doesn’t require any exter- 
nal processing or connections. After 
installation, the application is accessi- 
ble from the oscilloscope front panel. 

TEKTRONIX OSCILLOSCOPES 
SUPPORTED 

TDS 500D, TDS 700D series oscillo- 
scopes with Communication Signal 
Analyzer Option 2C and a hard disk 
drive (Option HD or Option 2M). 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



TDSCPMl 

Communications Pulse Measurement Software for 
TDS 500/700 Oscilloscopes. 

Includes: Software on a 3.5-in. Disk, Manual. 
Note: Requires TDS 500/600/700 Opt. HD or 2M. 



TDSCPMl RECOMMENDED OPTIONS AND 

ACCESSORIES 

AFTDS - Telecom Adapter. 

AMT75 - 75 D Adapter. 



For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

CC 

^ ISO 9001 

Tektronix measurement products are manufactured 
in ISO registered facilities. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPES 83 





Processor Specifications Measurements Software 

NEW TDSPSMl 




Processor Specifications 
Measurement Software 

► Your TDS 500/600/700 Series oscillo- 
scope can perform automated meas- 
urements on processor signal specifi- 
cations without external equipment 

► Installs inside the TDS oscilloscope 
requiring no external GPIB, RS-232 
or PC 

► Provided on floppy disk for easy 
installation 

► Uses familiar, user-friendly TDS user 
interface 

► Perform automated timing measure- 
ments of Ch-Ch delay, setup margin, 
hold margin, and clock to output 
timing 

► Perform automated AC specification 
measurements of rise, fall, high and 
low time 

► Analysis is performed on each and 
every valid pulse in a single-shot 
acquisition 

► Measurement results are returned 
with detailed statistics of: mean, 
min, max, standard deviation, and 
population 



APPLICATIONS 

► Precisely characterize the timing and 
AC performance of your digital 
designs 

► Measure timing from either or both 
edges of clock to either or both edges 
of data 

USER-INSTALLED, OSCILLOSCOPE RES- 
IDENT PROCESSOR SIGNAL MEASURE- 
MENT PACKAGE 

Microprocessors are used in a variety of 
industries and sub-systems. However, all 
these processors need to be integrated in 
a manner that will allow optimal opera- 
tion. The various processor manuals 
detail the electrical and interface per- 
formance that is required for proper 
operation of these processors. As an 
example, the Intel Processor Developer’s 
Manuals can be found on the WWW at 
http://intel.com/design/processor/. These 
measurements are generic to micro- 
processors and are useful across different 
processor types and across different gen- 
erations of a processor family. 



Many of the measurements in 
TDSPSMl can be performed today 
using the oscilloscope automatic meas- 
urements or histograms. TDSPSMl 
enhances this capability by providing 
direct measurements for each individ- 
ual edge or pulse and showing detailed 
statistics. For example, the setup time 
measurement in TDSPSMl is made for 
a specific data edge to the exact, corre- 
sponding clock edge. 

TDSPSMl comes on a single floppy 
disk, is easily installed in a TDS oscil- 
loscope, and doesn’t require any exter- 
nal processing or connections. After 
installation, the application is accessi- 
ble from the oscilloscope front panel. 

TEKTRONIX DIGITAL OSCILLOSCOPES 
SUPPORTED 

TDS 500D, TDS 600C, TDS 700D Series 
oscilloscopes with Option HD. 




TDSPSMl measurements are performed on all relevant data in a single-shot acquisition. 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 

TDSPSMl RECOMMENDED ACCESSORIES Jo, 

TDSJIT1 - Jitter Analysis Software. 1-503-627-191 6, inside the u.s. call: 1-800-426-2200. 

High-bandwidth Active Probes - P6245 1.5 GHz 
Active Probe. C € 

P6249 4 GHz Active Probe. IS O 9001 

Tektronix measurement products are manufactured 
in ISO registered facilities. 



TDSPSMl 

Processor Specifications Measurement Software for 
TDS 500/600/700 Oscilloscopes. 

Includes: Software on a 3.5-in. Disk, Manual. 
Note: Requires TDS 500/600/700 Opt. HD or 2M. 



84 OSCILLOSCOPES 



www.tektronix.com/Measureinent/scopes/ 





Disk Drive Measurement Software 

TDSDDIVI1 




Disk Drive Measurement 
Software 

► Your TDS 500D/600C/700D Series 
oscilloscope can perform disk-drive 
measurements without external 
equipment 

► Installs inside the TDS oscilloscope 
requiring no external GPIB, RS-232 
or PC 

► Provided on floppy disk for easy 
customer installation 

► Uses familiar, user-friendly TDS user 
interface 

► High-resolution measurements can 
be made on one channel at the high- 
est sample rate with trigger input 
from multiple channels 

► Comprehensive statistical measure- 
ments - mean, min, max, std dev, 
SNR and more for easy characteriza- 
tion of signals 

► Snapshot display of multiple parame- 
ters for detailed waveform information 

► SNR and NLTS measurements work 
for signal-to-noise ratios of 0 dB and 
below 

► Auto configures trigger inputs for 
index, sector and read channel for 
easy set-up 



► Thermal asperity information provided 
for quick problem detection 

► Track profile stores and displays 
measurement from each sector 
for various parameters 

► On-line help text provides informa- 
tion about each measurement 

► Part of a complete solution for disk- 
drive measurements from Tektronix 
- high-bandwidth differential 
probes, SMT probes, arbitrary wave- 
form generators, etc. 

► Lower price than other custom disk- 
drive measurement solutions that 
perform limited measurements 

APPLICATIONS 

► IDEMA measurements including 
TAA, PW50, overwrite, resolution 
and asymmetry 

► PRML measurements including auto- 
correlation NLTS and SNR 

USER-INSTALLED, OSCILLOSCOPE- 
RESIDENT DISK-DRIVE 
MEASUREMENT PACKAGE 

Design, manufacturing and failure 
analysis engineers at disk drive compa- 
nies; silicon vendors who design read- 
channel components; read/write head 
and media manufacturers - all desire to 
make measurements that are specific to 

Characteristics 

TEKTRONIX OSCILLOSCOPES SUPPORTED 



their industry. Performing measure- 
ments on disk-drive signals that comply 
with the IDEMA standards is crucial to 
meeting their objectives. 

Tektronix now offers a solution that pro- 
vides custom disk-drive measurements 
for the industry leading TDS oscillo- 
scopes. Peak detect measurements 
include track average amplitude posi- 
tive (TAA+), track average amplitude 
negative (TAA-), track average ampli- 
tude total (TAA), 50% pulse width posi- 
tive (PW50+), 50% pulse width negative 
(PW50-), 50% pulse width (PW50), 
overwrite and resolution. Timing meas- 
urements include time - trough-to-peak, 
and time - peak-to-trough. PRML meas- 
urements include autocorrelation non- 
linear transition shift and signal-to- 
noise ratio. Voltage and time asymmetry 
measurements are available for MR head 
designers. Measurement statistics are 
also available. 

TDSDDMl Disk-drive Measurement 
Software is a software package from 
Tektronix that dehvers industry-specific 
disk-drive measurements. It comes on 
floppy disks, is easily installed into a TDS 
500D/600C/700D oscilloscope and does- 
n’t require any external processing or 
connections. After installation, the appli- 
cation is accessible firom the front panel. 



TDSDDMl software operates on the following scopes: 

Instrument** Firmware Serial Number 



TDS724COpt2M 


v5.2e or later 


B020100 or greater 


TDS 754COpt2M 


v5.2e or later 


B020100 or greater 


TDS 784C Opt 2M 


v5.2e or later 


B020100 or greater 


TDS 500D 


Opt HD 




TDS 600C 


Opt HD 




TDS700D 


Opt HD 





Instruments must have Option HD, Hard Disk Drive. 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



TDSDDMl 

Disk-Drive Measurement Software for 
TDS 500D/700D. 

Includes: Software on 3.5-in. Disks, Manual. 
Note: Requires TDS 500/600/700 Opt. HD or 2M. 



TDSDDMl RECOMMENDED ACCESSORIES 
Arbitrary Waveform Generator - AWG 520 

Programmable Dual-channel Arbitrary Waveform 
Generator. 

High-bandwidth Differential Probe - P6247 
1 GHz Differential Probe. 

P6248 1.7 GHz Differential Probe. 



For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

CC 

Tektronix measurement products are manufactured 
in ISO registered facilities. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPES 85 





Power Measurement Software 

TDSPWR1 




Power Measurement 
Software 

► Your TDS 500D/600C/700D Series 
oscilloscope can perform customized 
power measurements without the 
need for a dedicated power system 
tester 

► Installs inside the TDS oscilloscope 
requiring no external GPIB, RS-232 
or PC 

► Provided on floppy disk for easy 
customer installation 

► Uses familiar, user-friendly TDS user 
interface 

► Graphic and table print-out of cur- 
rent harmonics to easily view and 
document AC-line performance in 



either spectral or tabular form 

► Direct reading of true power, 
apparent power and power factor 
measurements to eliminate manual 
calculations 

► Part of a complete solution for 
power measurements from Tektronix 
— voltage probes, high— and low- 
voltage differential probes, differen- 
tial amplifiers, high— and low-cur- 
rent probes, current-probe ampli- 
fiers, isolation systems, etc. 

► Measurements include instantaneous 
power and energy on long records 
with automatic display of power and 
energy 

► Lower price than other custom 
power measurement systems that 
perform limited measurements 

APPLICATIONS 

► Pre-compliance testing to CE stan- 
dard per EN 61000-3-2 

► Characterizing switching losses of 
IGBTs 

USER-INSTALLED, OSCILLOSCOPE- 

RESIDENT POWER-MEASUREMENT 

PACKAGE 

Engineers in the semiconductor indus- 
tries who design IGBTs, power 

MOSFETs and electric motor drive ICs 



for the power supply industry need to 
make specialized energy curve meas- 
urements. Engineers designing switch- 
ing power supplies, electric motors and 
ballasts for electrical lighting need to 
measure power on their sub-systems. 
Engineers designing products for the 
European market must ensure compli- 
ance to the EN 61000-3-2 standard. 

Tektronix now offers these and others a 
solution that provides custom power 
measurements for the industry leading 
TDS oscilloscopes. Features include cal- 
culation of instantaneous power and 
energv curves from voltage and current 
input. Automatic measurements include 
true power, apparent power and power 
factor. In addition, this package pro- 
vides pre-compliance testing to EN 
61000-3-2 with a minimum of difficulty. 

TDSPWRl Power Measurement 
Software is a software package from 
Tektronix that delivers industry-specific 
power measurements. It comes on flop- 
py disks, is easily installed onto a TDS 
500D/600C/700D oscilloscope, and 
doesn’t require any external processing 
or connections. After installation, the 
application is accessible from the oscil- 
loscope front panel. 



Characteristics 



TEKTRONIX OSCILLOSCOPES SUPPORTED 

TDSPWRl software operates on the following scopes: 



Instrument*' 

TDS 724C Opt 2M 


Nrmware 

V5.2e or later 


B020100 or greater 


TDS 754C Opt 2M 


V5.2e or later 


B020100 or greater 


TDS 784C Opt 2M 


V5.2e or later 


B020100 or greater 



TDS 500D, TDS 600C, TDS 700D series oscilloscopes with option HD. 



*' Instruments must have Option HD, Hard Disk Drive. 



Ordering Information 



For price information: Outside the U.S. contact 

TDSPWRl 

Power Measurement Software for TDS 500D/700. 
Includes: Software on 3.5-in. Disks, Manual. 

Note: Requires TDS 500/600/700 Opt. HD or 2M. 



your local Tektronix representative, inside the U.S. 

TDSPWRl RECOMMENDED ACCESSORIES 
High-Voltage Differential Probe - P5205 Active 
Differential Probe. 

Current Probe - TCP202 DC Coupled Current 
Probe. 



in the back of this catalog. 

For your local Tektronix representative see the list in 
the oack of this catalog or outside the U.S. call: 
1 - 503 - 627 - 1916 , inside the U.S. call: 1 - 800 - 426 - 2200 . 

C€ 

ISO 9001 

Tektronix measurement products are manufactured 
in ISO registered facilities. 



see 



86 



OSCILLOSCOPES 



www.tektnMiix.coiiVMcasureinefit/scopes/ 





Enhanced Printing Utility Software 

TDSPRT1 




Enhanced Printing Utility 
Software 

► Available for free download from the 
WWW 

► Uses familiar, user-friendly TDS user 
interface 

► Prints up to 2000 pages of waveform 
data 

► Allows printing of entire record or 
region between cursors 

► Print preview mode allows quick 
high resolution viewing of long 
records 

► Print preview mode allows pages to 
be marked or unmarked for printing 

► Help page 

APPLICATIONS 

► View data on multiple sectors of a 
disk drive 

► View header information in a com- 
munications data stream 



USER-INSTALLED OSCILLOSCOPE- 
RESIDENT ENHANCED PRINTING 
UTILITY 

Electronic design engineers in the disk 
drive, communications and other relat- 
ed industries that use long records 
need to view a hardcopy of a long 
record. Customers in the disk drive 
industry want to view anomalies on 
certain sectors of data. Customers 
designing modems want hardcopies of 
start-up sequences that detail threshold 
changes with different digital modula- 
tion schemes. Bio-Medical customers 
want to print out long records to evalu- 
ate several minutes of activity from 
their pacemakers. 

Tektronix now offers a solution that pro- 
vides enhanced printing capabilities for 
the industry-leading TDS oscilloscopes. 
Using the familiar TDS user interface, 
customers can now easily navigate long 
records and conveniently print only 
screens that are of interest to them. 



TDSPRTl is a Software package from 
Tektronix that delivers enhanced print- 
ing capabilities. It is available for free 
by following the installation instruc- 
tions from the following URL: 
www.tektronix.com/Measurements/scopes. 
After installation, the application will 
be accessible from the oscilloscope 
front panel. 

SYSTEM REQUIREMENTS 

TDSPRTl will operate on the following 
Tektronix Digital Storage Oscilloscopes: 

Instruments must have Option HD, 

Hard Disk Drive. 

Instruments must also have TDSRTEl 
(Run Time Environment) installed to 
run the application. 



Tektronix Oscilloscopes Supported 



Instrument fw 



TDS 724C OpL 2M 


V5.2e or later 


B020100 or greater 


TDS 754C Opt 2M 


V5.2e or later 


B020100 or greater 


TDS 784C Opt 2M 


V5.2e or later 


B020100 or greater 


TDS 500D, TDS 600C, TDS 700D, 


series oscilloscopes with option HD 





Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



Application and instructions can be downloaded for 
free from the www at: 

www.tektronixcom/Measurement/scopes 



For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call; 1-800-426-2200. 

CC 



pg ISO 9001 

Tektronix measurement products are manufactured 
in ISO registered facilities. 



www.tektronix.com/Measurenient/scopes/ 



OSCILLOSCOPES 87 





Digital Sampling Oscilloscopes 



TDS 820 




Features - Benefits 



0.4 ps Timing Resolution 

20 ps/div to 2 ms/div Sweep 
Speeds in 5 ps Steps 

2 GHz External Trigger Bandwidth 

3 ps RMS Jitter 

Infinite and Variable Persistence 
Displays 

14-Bit Vertical Resolution 
27 Automatic Measurements 
Full GPIB Programmability 
Optional Hardcopy Interface 

Optional Advanced DSP Waveform 
Math Including FFT, Integration and 
Differentiation 



Applications 



Telecom Service and Manufacturing 
Semiconductor Characterization 

Digital System Design and 
Characterization 
Electronic Mask Drawing and 
Display 

Automatic Pass/Fail Limit Testing 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 



C€ 



■ ISO 9001 



Tektronix measurement 
products are manufactured in 
ISO registered facilities. 



Product(s) complies with IEEE 
Standard 488.2-1987, 
and with Tektronix Standard 
Codes and Formats. 



Characteristics 



SIGNAL Acquisitioii System 


TDS 820 


TDS 820 Opt ID 


Channels 


2 


2 


Rise time 


58.3 PS 


43.8 ps 


Bandwidth (0.35/rise time) 


6 GHz 


8 GHz 


Max operating input voltage 


2Vp^,;±3VDC 


1 V„;±1.5VDC 


Sensitivity 


2 m V/div to 
200 mV/div 


1 mV/divto 
100 mV/d‘iv 


Random noise 


1.2 mV max, 
600 pV typical 


600 pV max, 
300 pV typical 



DC Cain Accuracy - ±0.7% after user-initiated auto- 
matic vertical calibration. 

Vertical Resolution - 14-Bits (Approx. 16,384 levels 
over 10.24 vertical divisions). 

Input Impedance -50Q. 

ACQUISITION MODES 

Normal - One sample acquired with each trigger event. 
Envelope - Max/min values acquired over one or 
more acquisitions. 

Average - Waveform averages selectable from 2 to 10,000. 

TIME BASE SYSTEM 
Time Bases - Main, Delayed. 



rime/Division Range - 20 ps/division to 5 ms/diyision 
in 1-2-5 steps or settable from the numeric keypad in 5 ps 
steps. 

Delta time measurement accuracy - 



rime interval 


Accuracy 


Ti >1 ns 


0.1% X interval +15ps 


loops 


5PS 


10 PS 


?_ES. 


Channel Deskew 


- Up to 100 ns (each channel). 


Record Length - 


500, 1000, 2000, and 5000, and 


15,000 samples per channel. 


Pre “Trigger View Time - 1.5 ns. 



TRIGGERING SYSTEM 

Trigger Sources - External input, internal rate genera- 
tor, CH 1, CH 2. 

External Trigger Sensitivity - 40 mVp.p from DC to 
200 MHz, increasing linearly to 200 mVp.p at 2 GHz. 
External Trigger Minimum Pulse Width - 0.25 ns. 
Internal Trigger Sensitivity - 80 mVp.p from DC to 
200 MHz, increasing linearly to 400 mVp.p at 1 GHz. 
Trigger Delay Jitter - 3 ps RMS + 30 ppm of time base 
delay. 

HoldoH Range - 15 ps to 2 s. 



88 OSCILLOSCOPES 



wv¥W.tektronix.com/Measurefflent/scopes/ 







Digital Sampling Oscilloscopes 

TDS 820 



DISPLAY 

Waveform Style - Dots or vectors. Infinite 
and variable persistence from 250 ms to 10 s. 
Cray Scaling - With variable persistence 
selected, waveform points gradually decay 
through 16 levels of intensity, providing "z-axis" 
information about rapidly changing waveforms. 
Graticules - Full, grid, cross hair, frame. 
Format -YTandXY. 

CRT Type - 7 In. diagonal, magnetic deflec- 
tion. Horizontal raster-scan. P4 White phosphor. 
CRT Resolution - 640 horizontal by 480 ver- 
tical displayed pixels. 

MEASUREMENT SYSTEM 
Automatic waveform measurements - 



h.!«!i 


Low 




+ Width 


-Width 




Maximum 


Minimum 




Rise 


Fall 




Peak to Peak 


Amplitude 




+ Duty Cycle 


- Duty Cycle 




+ Overshoot 


- Overshoot 




Propagation Delay Burst Width 


Mean 


Cycle Mean 




RMS 


Cyde RMS 




Phase 


Cyde Area 




+ Cross 


- Cross 




Area 



Continuous update of up to four measure- 
ments on any combination of waveforms. 
Snapshot mode shows all measurements on 
the selected waveforms. 

Thresholds - Settable in percentage or voltage. 

Cursor Measurements - Absolute, 

Delta; Volts, Time, Frequency. 

Cursor Types - Horizontal bars (volts); Vertical 
bars (time); Paired (volts and time). 

WAVEFORM PROCESSING 
Waveform Functions - Interpolate-selec- 
table sin(x)/x or linear. Average, FFT, integrate, 
and differentiate. 

Arithmetic Operators - Add, Subtract, 
Multiply, Invert. 

Autosetup - Single button, automatic setup 
on selected input signal for vertical, horizontal 
and trigger systems. 

COMPUTER INTERFACE 

GPIB (IEEE -488.2) Programmability - 

Full talk/listen modes. Control of all modes, 
settings, and measurements. 

HARD COPY 

Formats - HP ThinkJet, Epson, Postscript, 
Interleaf, DeskJet, LaserJet, EPS Monochrome, 
EPS Color, TIFF, PQ, BMP, HPGL. 

Optional Hardcopy Interface - Centronics 
and RS-232C. 



STORAGE 

Waveforms - Up to 15 K points. 

Setups - 10 front-panel setups. 

. POWER REQUIREMENTS 
Line Voltage Range - 90 to 250 V RMS. 
Line Frequency - 47 to 63 Hz. 

Power Consumption - 250 W max. 

ENVIRONMENT AND SAFETY 
Temperature - Operating: 0 to +50°C. non- 
operating: -40 to +75°C. 

Humidity - Operating and nonoperating: Up 
to 95% relative humidity at or below +40°C; to 
75% relative humidity from +41 °C to 50°C. 
Altitude - Operating: 15,000 ft. nonoperating: 
40,000 ft. 

Electromagnetic Compatibility - Meets 
MIL-STD-461C, CE-03, Part 4, Curve # 1, RE-02, 
Part 7; meets VDE 0871, Category B, FCC rules 
and regulations. Part 15, Subpart B, Class A. 
Safety - UL3111-1, CSAlOlO.l, EN61010-1, 
IEC61010-1. 



Physical Characteristics 

Dimensions mm in. 



Height 


193 


7.6 


wjth acc. pouch 


236 


9.3 


Width 


445 


17.5 


Depth with front cover 


432 


17 


Weight 


kg 


lbs. 


Net 


13.2 


29.1 


Shipping 


23.6 


52 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



TDS 820 

2-CH, 8 GHz Digital Sampling Oscilloscope. 

Includes: Reference (070-8511-01), User Manual 
(070-8512-01), Programmer Manual (070-8513-01), 
Performance Verification Manual (070-8696-00), U.S. 
Power Cord (161-0230-01), Two 12-inch 50 Q Male-to- 
Male SMA Cables (174-1364-00), 60-inch 50 Q Male- 
to-Male SMA Cable (174-1428-00), Antistatic Grounding 
Wrist Strap (006-3415-04), SMA 'T' (015-1016-00), SIVIA 
Female-to-Female Adapter (015-1012-00), Two SMA 
Short Circuit Male Terminations (015-1020-00), Front 
Cover (200-3696-00). 

Opt. 13 - RS-232/CENTRONICS Hardcopy Interface. 
Opt. 1R - Rackmount. 

Opt. B1 - Service Manual. 

Opt. 32 - Add 1 Each P6207 Probe. 



INTERNATIONAL POWER PLUGS 

Opt. A1-A5 available. 

See page 619 for description. 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of Calibration Services. 

Opt. D3 - Test Data (requires Opt. C3). 

See page 615 for further information. 

RECOMMENDED ACCESSORIES 

Also see page 495. 

PROBES 

Active - 3.5 GHz, 0.4 pF/100 kn, 1 m. Order P6207. 
Differential - 1 GHz, active differential, 6 ft. Order 
P6247. (Requires 1103 Power Supply.) 

50 Q Divider - 9 GHz, 0.15 pF/500 Q, Tips IX, 
lOX. 1 m. Order P6150. 

Carts - Order K420 Scope Cart. 

Static Isolation Unit - Order SIU800. 



SOFTWARE 

WSTRO - WaveStar™ software for oscilloscopes, 
Windows 95/98/NT application for waveform capture, 
analysis, documentation and control from your PC. 
WSTROU - Upgrade from WSTR31 to WSTRO. 
WSTR31 - WaveStar™ software for Windows 3.1. 

WSTR31 U - Upgrade from DocuWave ® software to 
WSTR31. 

LVWIN95 - LabVIEW ^ for Windows 95. 

LVWCVI95 - LabWindows/CVI for Windows 95. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

C€ 

pgiso^i 

Tektronix measurement products are manufactured 
in ISO registered facilities. 



Product(s) complies with IEEE Standard 488.2-1987, 
and with Tektronix Standard Codes and Formats. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPES 89 





GPIB-LAN Adapter 

AD007 




Features - Benefits 



Control Tektronix Oscilloscopes and 
Other Instruments via a LAN-Based 
(Ethernet) TCP/IP Network PC 

Interface Up to 14 GPIB Devices to 
Each AD007 

Talk to Several GPIB Instruments/ 
Systems from Several Networked PCs 

Print to Networked Printers 
Ethernet Twisted Pair (lOBaseT) 
Adapter 

Operates on All Windows 95/98 
and NT 4.0 Operating Systems 

Compatible with WaveStar for 
Oscilloscopes Applications 
Software and Custom, Proprietary 
Programs (C, C-h-h, or 
Microsoft Visual Basic) 



Applications 



Digital Design 

Research and Development 
Manufacturing Test 
Sen/ice and Support 
Education 

Web Page-based Configuration and 
Statistics 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call; 
1-800-426-2200. 



C€ 



j£ ISO 9001 

Tektronix measurement 
products are manufactured in 
ISO registered facilities. 



Product(s) complies with IEEE 
Standard 488.1-1987, RS-232-C, 
and with Tektronix Standard 
Codes and Formats. 



Instrument to Local Area Network 
(LAN) Connectivity 

Control your Tektronix TDS Series oscilloscope 
from any networked PC. Check on its status, or 
capture waveforms any time you want from your 
office, another site, or from anywhere using 
WaveStar™ application software or your own 
software. Or command your TDS Series oscillo- 
scope to print to a networked printer. 

The Tektronix GPIB-LAN Adapter takes advantage 
of the fact that many of today’s computers are con- 
nected together through an Ethernet lOBaseT LAN. 

PRINT TO NETWORKED PRINTERS 

Using any web browser, select the networked 
printer to which your TDS Series oscilloscope will 
print and route your hardcopy output to your high 
quality monochrome or color networked printer. 

WINDOWS 95/98 OR NT 4.0 COMPATIBILITY 

You don’t need to understand or program 
Ethernet protocols. Both communications 
and Virtual Instrument Software Architecture 



(VISA) software for Windows 95/98 or NT 4.0 is 
included free with the GPIB-LAN Adapter. Now, 
you can also perform waveform capture from 
your TDS Series oscilloscopes across the LAN by 
using Tektronix WaveStar for Oscilloscopes 
application software. Or write a program using 
C, C-I-+, or Microsoft Visual Basic to capture data 
or control your instrument. As long as the pro- 
gram is written using the standard VISA inter- 
face, the GPIB-LAN Adapter’s software will turn 
your PC into a GPIB Talker, Listener, Controller. 

NETWORK DETAILS 

The AD007 implements a full range of adapter 
functions and Ethernet-based TCP/IP protocols. 
It operates with all of the popular network pro- 
tocols such as BOOTP, DHCP, DNS, LPD, HTTP, 
and FTP. 

CONFIGURATION AND STATISTICS 

Use a web browser to configure features; exam- 
ine GPIB commands, Ethernet traffic statistics, 
and GPIB traffic statistics; and initiate diagnostic 
GPIB commands. 



90 OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 




GPIB-LAN Adapter 

AD007 




EASE OF INSTALLATION 

Simply connect your AD007 to your 
LAN with the cable provided, connect 
the GPIB interface to your instruments, 
and power up the unit. It automatically 
requests an IP address from the net- 
work’s Boot Server, or this can be manu- 
ally entered using the adapter’s internal 
web page. Upon power-up, the unit also 
performs hardware diagnostics/self-test. 
Status indicators on the unit give evi- 
dence of successful completion of this 
testing, connection to the LAN, and 
both LAN and GPIB traffic. 

Any number of AD007 Adapters may be 
used to connect any combination of 
GPIB devices to the network. (NOTE: 
Limit of 14 devices per GPIB cluster.) 



Characteristics 



SYSTEM REQUIREMENTS 
Computer Type - IBM PC-compatible with 
Windows 95/98 or NT 4.0 Operating System. 
Consult Microsoft documentation for recom- 
mended configuration. 

Hard Disk - 5 Mbytes or greater. 

RAM - Consult Microsoft documentation for 
recommended minimum configuration. 
CD-ROM - Required. 

NOTE: For printing only a web browser is 
required. 

NETWORK COMPATIBILITY 
Ethernet Port - lOBaseT, RJ-45 connector. 
Protocols - BOOTP, DHCP, LPD, DNS, HHP, 
FP. 

Networked Printer - Compatibility: Must be 
compatible with the GPIB instrument's hard- 
copy output format Print Protocol: Must sup- 
port LPD Network Print protocol. 



IEEE 488 (GPIB) 

Compatibility 

Connection - No cable required for most 
applications. 

Compatibili^ - Fully IEEE488.2 compatible. 
NOTE: Not suitable for connection to the public 
telecommunications (telephone) network. 

OTHER 

Transmission Rate - Up to 10 Mbps on 
Ethernet; dependent on slowest GPIB device 
on the bus. 

Front-Panel Indicators - Power, LAN-Link, 
LAN, GPIB. 

ENVIRONMENTAL 
Temperature - Operating: 0 to +45®C. 
Nonoperating: -20 to +70°C. 

Humidity - 30 to 45®C, 90 to 95%, relative 
humidity. 

Altitude - Operating: Up to 2,000 m (6,500 ft.). 
Nonoperating: Up to 10,000 m (33,000 ft.). 
Vibration - 3 axis, 60 minutes total, 20 min- 
utes/axis (10 minutes operating, 10 minutes 
non-operating). 

Shock - Half sine, 500 g, 3 axis, 3 drops each 
axis. 

EMC COMPLIANCE 

Meets the intent of EMC Directive 89/336/EEC. 
Complies with FCC Part 15, Class A limits. 

SAFETY COMPLIANCE (POWER SUPPLY) 

EN60950 (CE Mark). UL1950. 

CAN/CSA 22.2 No. 950. 

DENTORI (T-MARK). 

POWER 

Source Power - Voltage Ranges: 100 to 
240 VAC ±10%. Line Frequency: 50 to 60 Hz. 

Power Consumption - Regulated 5 VDC at 
300 mA, typical. 

Physical Characteristics 

Dimensions - H (35.6 mm/1.4 In.) x W (76.2 
mm/3 in.) x D (120.2 mm/4.7 in.). 

Weight - Net (0.15 kg/0.34 lb.). 

WARRANTY 

One year parts and labor. 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the hack of this catalog. 



AD007 

GPIB-LAN Adapter. 

Includes: Adapter, Regulated Power Supply, CD- 
ROM software, RJ-45 Cable, Manual. 



AD007 INTERNATIONAL POWER PLUGS 

Opt. AO - A6 Available. 

See page 619 for description. 



For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

C€ 



ISO 9001 



Tektronix measurement products are manufactured 
in ISO registered facilities. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPES 91 






Digital Storage Oscilloscopes 

TDS 430A • TDS 460A • TDS 420A 




For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 



Features - Benefits 



Be Confident You're Seeing Actual 
Signals with up to 400 MHz 
Bandwidth and ±1.5% Accuracy 

Capture Transient Events to the Full 
Scope Bandwidth with Its 100 MS/s 
Sample Rate 
2 and 4 Channels 
Record Lengths to 120 K (Opt. XL) 
Floppy Disk Storage 

Speed Up Your Circuit Analysis with 
25 Built-in Automatic Measurements 
and Extended Waveform Math/FFT 
(Opt. XL) 

Roll Mode Allows You to See 
Acquired Data Points Without 
Waiting for the Acquisition of the 
Complete Waveform 

Use the Video Trigger Mode to See 
NTSC, PAL, SECAM Signals or Your 
Own Custom Video Signals 

Capture Those Glitches with the 
10 ns Peak Detect Mode 

DIFFERENTIAL MEASUREMENTS 

ADA400A Analog Differential 
Amplifier (10 pV/div sensitivity) 

P5200/P5205/P5210 High Voltage 
Differential Probes (up to 5600 V) 
for Floating Measurements 



Applications 



Biophysical/Biomedical Research 

Electrophysical and 
Electromechanical System Design 

Audio System Measurement and 
Analysis 

Manufacturing Test and Quality 
Control 

Power Supply and Power-related 
Design 

Product Service and Maintenance 



Product(s) available through 
your local Tektronix Distributor 
listed in the back of this catalog. 

C€ 

j£ ISO 9001 

Tektronix measurement 
products are manufactured in 
ISO registered facilities. 




Product(s) complies with IEEE 
Standard 488.1-1987, 
and with Tektronix Standard 
Codes and Formats. 



TDS 400A Digital Storage 
Oscilloscopes 

For professionals who demand high precision 
and fidelity from their measurements, the TDS 
400A Digital Storage Scopes combine excellent 
performance and broad feature set. all at afford- 
able prices. A choice of 2 and 4 channel models 
ranging from 200 MHz to 400 MHz with a 100 
MS/s sample rate on all channels makes the 
TDS 400A Series a worthy fit for a variety of 
demanding applications. 



The highly featured, portable and easy to use 
TDS 420A, 430A and 460A personal lab scopes 
are ideal for simple to complex applications, 
including electro-mechanical research and 
analysis, power electronics/power supply 
design, bio-physical research and analysis, digi- 
tal and analog design. With its standard video 
trigger capability, the scopes are ideal instru- 
ments for measuring video signals including 
NTSC, PAL and SECAM. 



92 OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 





Digital Storage Oscilloscopes 

TDS 430A • TDS 460A • TDS 420A 



The TDS 400A Series uses the 
renowned TDS Graphical User Interface 
which offers intuitive icon-based menus 
along with help text, making scope 
operation extremely simple. Knobs and 
buttons allow easy selection of com- 
monly used scope fiuictions. The stan- 
dard floppy disk drive makes the saving 
of screen images or data to a disk sim- 
ple. The disk can then be inserted into 
your PC for importing to desktop pub- 
lishing or spreadsheet programs. 

Please see page 556 and page 560 for 
details on ADA400A, P5200, P5205 
and P5210. 



Characteristics 




Theoretically achievable resolution with 
TDS 400A Hi-res Mode. 



SIGNAL ACQUISITION SYSTEM 
Bandwidth - 200 MHz (TDS 420A), 400 MHz 
(TDS 430A, TDS 460A). 

Channels - 4 (2 on TDS 430A). 

Sample Rate - 100 MS/s on all channels. 
Sensitivity - 1 mV to 10 V/div (with calibrated 
fine adjust). 

Position Range - ±5 Divisions. 

Offset Range - ±1 V from 1 mV/div to 
99.5 mV/div; ±10 V from 100 mV to 995 mV/div 
; ±100 V from 1 V/div to 10 V/div. 

DC Gain Accuracy - ± 1 . 5 %. 

Verticai Resolution - 8-Bits (256 levels over 
10.24 vertical divisions). 

Analog Bandwidth Selections - 20 MHz, 

100 MHz and full. 

Input Coupling - AC, DC or GND. 

Input Impedance Selections - 1 M^2 in par- 
allel with 15 pF, or 50 Q (AC and DC coupling). 
Maximum Input Voltage - 300 V CAT II 

±400 Vpeak. Derate at 20 dB/decade above 
1 MHz. 1 MQ or GND coupled. 

Channel Isolation - >100:1 at 100 MHz for 

any two channels. 

AC Coupled Low Frequency Limit - <10 Hz 

when AC 1 MQ coupled. <200 kHz when AC 
50 Q coupled. 



ACQUISITION MODES 
Peak Detect - High frequency and random 
glitch capture. Captures glitches of 10 ns 
using acquisition hardware at all real-time 
sampling rates. 

Sample - Sample data only. 

Envelope - Max/min values acquired over 
one or more acquisitions, selectable from 2 to 
2000, infinite. 

Average - Waveform averages selectable 
from 2 to 10,000. 

Hi-res - Vertical resolution improvement and 
noise reduction on low-frequency signals, e.g. 
12-Bits at 10 ms/div and slower. Enhanced ver- 
tical resolution (> 12-Bits) for noise reduction, 
on low frequency signals. Make precise low- 
level signal measurements (up to 5 pV) with 
differential amplifier (ADA400A). 

TIME BASE SYSTEM 
Time Bases - Main, Delayed. 

Time/Division Range - 1 ns to 20 s/div. 
Time Base Accuracy - 0.015% over any 
interval >1 ms. 

Record Length (Real Time and Equivalent 
Time) - Sample points per channel: 500 to 
120,000 points (with Opt. XL). 

Pre-trigger Position - Selectable from 0 to 
100% of record. 

TRIGGERING SYSTEM 
Triggers - Main, Delayed. 

Main Trigger Modes - Auto, Normal, Single 
Sequence. 

Delayed Trigger - Delayed by time or events. 
Time Delay Range - 0 ns to 20 s. 

Events Delay Range - 2 to 10,000,000 events. 
External Rear Input - >1.5 kQ; Max input 
voltage is ±6 V (DC + AC peak). 

Video Trigger Types - NTSC, PAL, SECAM 
and custom; TV field, field 2 or both, any line 
within a field. Line rates -10 kHz to 64 kHz, 
interlaced, non-interlaced, composite. 

Video Trigger Sensitivity - 0.6 divisions of 
composite SYNC will achieve a stable display. 

DISPLAY 

Waveform Style - Dots or vectors. Infinite 
and variable persistence from 250 ms to 10 s. 
Cray Scaling - With variable persistence 
selected, waveform points gradually decay 
through 16 levels of intensity, providing "z-axis" 
information about rapidly changing waveforms. 
Update Rate - 200 ea. 500 point waveforms 
per sec with infinite persistence mode selected. 
Graticules - Full, grid, cross hair, frame. 
Format - YT and XY. 

VGA Out - Drives VGA display monitors. 



ZOOM 

The zoom feature allows waveforms to be 
expanded, compressed and positioned in both 
vertical and horizontal axes. Allows precise 
comparison and study of fine waveform detail 
without affecting ongoing acquisitions. When 
used with Hi-res or Average acquisition modes. 
Zoom provides an effective vertical dynamic 
range of 1000 divisions or 100 screens. 



Measurement System 

Automatic waveform measurements - 


Period 


Frequency 


High 


Low 


+ Width 


-Width 


Maximum 


Minimum 



Rise 

Peakto Peak 
+ Duty cycle 
+ Overshoot 
Propagation delay 
Mean 
RMS_ 

Area 

Phase 



Fall 

Amplitude 
- Duty cycle 
Overshoot 
lurst Width 



Cycle Mean 
. Cyde MS 
Cyde Area 



Continuous update of up to four measure- 
ments on any combination of waveforms. 
Thresholds - Settable in percentage or voltage. 
Gated - Any region of the record may be iso- 
lated for measurement using vertical bars. 
Snapshot - Performs all measurements on 
any one waveform showing results from one 
instant in time. 

Cursor Measurements - Absolute, 

Delta, Volts, Time, Frequency. 

Cursor Types - Horizontal bars 
(volts); Vertical bars (time); paired; operated 
independently or in tracking mode. 



WAVEFORM PROCESSING 
Waveform Functions - Interpolate-selectable 
sin(x)/x or linear. Average, Envelope. 
Advanced Waveform Functions - FF, 
Integration, Differentiation (Opt. XL). 
Arithmetic Operators - Add, Subtract, 
Multiply, Invert. 

Autosetup - Single button, automatic setup 
on selected input signal for vertical, horizontal 
and trigger systems. 

Waveform Limit Testing - Compares incom- 
ing waveform to a reference waveform's upper 
and lower limits. 



COMPUTER INTERFACE 
GPIB (IEEE 488.2) Programmability - Full 
talk/listen modes. Control of all modes, settings 
and measurements. 



www.tektronix.coRi/Measuranent/scopes/ 



OSCILLOSCOPES 93 





Digital Storage Oscilloscopes 

TDS 430A • TDS 460A • TDS 420A 



HARDCOPY/DESKTOP PUBLISHING 
Printer - HP ThinkJet, Epson, PostScript, 
Interleaf, DeskJet, LaserJet, TIFF, PCX, BMP 
(Microsoft Windows). 

Plotter - HPCL. 

Interface - GPIB standard. 

Hardcopy Interface - Centronics Type and 
RS-232 (Opt. XL). 

STORAGE 

Waveforms - 120,000 waveform points of 
non-volatile storage (with Opt. XL). 

Floppy Drive - 3.5 in. 1.44 MB or 720 KB 
DOS compatible (store waveforms, screen 
data, and setups)*^ 

Setups - 10 front-panel setups. 



CRT 

Type - 7 in. diagonal, magnetic deflection. 
Horizontal raster-scan. P31 green phosphor. 
Resoiution - 640 horizontal by 480 vertical 
displayed pixels. 

POWER REQUIREMENTS 

Line Voitage Range - 90 to 250 V RMS. 

Line Frequency - 48 to 440 Hz. 

Power Consumption - 240 W max. 

ENVIRONMENTAL AND SAFETY 
Temperature - Operating: 0®C to +50®C. 
Nonoperating: -40°C to +75®C. 

Humidity - Operating and nonoperating: Up 
to 95% relative humidity at or below +40°C; to 
75% relative humidity from +41 ®C to +50®C. 
Aititude - Operating: 15,000 ft., nonoperating: 
40,000 ft. 



Eiectromagnetic Compatibiiity - Meets 
MIL-STD-461C, CE-03, Part 4, Curve # 1, RE-02, 
Part 7; meets VDE 0871, Category B, FCC rules 
and regulations, Part 15, Subpart J, Class A. 
Safety - UL3111-1, CSAIOIO.I, EN61010-1, 
IEC61010-1. 

Physical Characteristics 



Dimensions 


mm 


in. 


Height 


164 


6.4 


w/acc. pouch 


177 


7.5 


Width 


362 


14.25 


Depth w/front cover installed 


491 


19.25 


Depth w/handle extended 


576 


22.2 


WCigM 


J* 


lbs. 


Net approximately 


9.1 


22.5 


Shipping approximatelY 


12.5 


32 



Waveforms can be stored to file in MathCAD 
and Spreadsheet (Excel. Lotus 1-2-3) formats 
for analysis. 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



TDS 430A (order with Opt. XL) Two-Channel, 

400 MHz Digitizing Oscilloscope. 

TDS 420A (order with Opt. XL) Four-Channel, 

200 MHz Digitizing Oscilloscope. 

TDS 460A (order with Opt. XL) Four-Channel, 

400 MHz Digitizing Oscilloscope. 

All include: 1 Probe Per Channel (P6138A lOX 
Passive Probes); Video Trigger; Reference Manual 
(070-8035-03); User Manual (070-8034-03); 
Performance Verification Document (070-8721-02); 
U.S. Power Cord (161-0230-01). 

INSTRUMENT OPTIONS 
Opt. XL - (mandatory for all TDS 400 models) 
120,000 Point Record Length; RS-232 and Centronics 
Hardcopy Interfaces; Extended Waveform Math: FFT; 
Integration, Differentiation; Front Cover and 
Accessories Pouch. 

Opt. 1R - Rack Mount. 

Opt. D1 - NIST, MIL-STD-45662A and ISO 9000 
Calibration Data Report. 

PROBES 

See page 498. 

Differential Probes - 

400 MHz, 30 dB CMRR. Order P6246. 

High Voltage Probes - 
2.5 kV, 25 MHz. Order P5100. 

20 kV, 75 MHz. Order P6015A. 

High Voltage Differential Probes - 
Up to 1300 V, 25 MHz. Order P5200. 

Up to 1300 V, 100 MHz. Order P5205. 

Up to 5600 V, 50 MHz. Order P5210. 

Passive Probe lx - Order P6101B. 

Passive Probe lOx - Order P6138A. 



FET Probe - Order P6205. 

SMT Probe - Order P6562A. 
m Logic Probe - Order P6408. 

Optical Converters - 

500 nm to 950 nm. Order P6701 B. 

1100 nm to 1700 nm. Order P6703B. 

DC/AC Current Probe System - Order AM 503S, 
or TCP202 DC Coupled Current Probe. 

RECOMMENDED ACCESSORIES- 

Analog Differential Amplifier - 10 pV sensitivity. 

Order ADA400A. 

Current Measurement Capability - Order TDS 400A 
and AM 503S, and appropriate probe. 

Also see page 495. 

Scope Cart - Order K212. 

Rackmount Kit - Order 016-1166-00. 

Soft-sided Carrying Case - Order 016-1158-01. 
lyansit Case - Order 016-1157-00. 

Programmer's Manual - Order 070-9876-00. 
Service Manual - Order 070-9703-04. 

Video Clamp - Order 013-0278-00. 

SOFTWARE 

WSTRO - WaveStar™ software for Oscilloscopes, 
Windows 95/98/NT application for waveform capture, 
analysis, documentation and control from your PC. 
WSTROU - Upgrade from WSTR31 to WSTRO. 
WSTR31 - WaveStar™ software for Windows 3.1. 
LVWIN95 - LabVIEW'' for Windows 95. 

LWCVI95 - LabWindows/CVI for Windows 95. 

CABLES 

GPIB- 

1 meter. Order 012-0991-01. 

2 meters. Order 012-0991-00. 



INTERNATIONAL POWER PLUGS 
Opt. A! - Universal Euro 220 V, 50 Hz. 

Opt. A2 - UK 240 V, 50 Hz. 

Opt. A3 - Australian 240 V, 50 Hz. 

Opt. A4 - North American 240 V, 60 Hz. 

Opt. AS - Switzerland 220 V, 50 Hz. 

See page 619 for description. 

International power options required on instruments 
and selected accessories for operation outside U.S. 
For operation outside U.S., specify A1-A5 power 
options. See General Customer Information pages for 
additional description. 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of Calibration Services. 

Opt. D1 - NIST, MIL-STD-45662A and ISO 9000 
Calibration Data Report. 

Opt. D3 - Test Data (requires Opt. C3). 

See page 615 for further information. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-S03-627-1916, inside the U.S. cali: 1-800-426-2200. 

Product(s) available through your local Tektronix 
Distributor listed in the back of this catalog. 

C€ 

ag ISO 9001 

Tektronix measurement products are manufactured 
in ISO registered facilities. 



Product(s) complies with IEEE Standard 488.1-1987, 
and with Tektronix Standard Codes and Formats. 



94 OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 




Digital Phosphor Oscilloscopes 

New TDS 3012 • TDS 3014 • TDS 3032 • TDS 3034 • TDS 3052 • TDS 3054 




For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1 - 503 - 627 - 1916 , 
inside the U.S. call: 
1 - 800 - 426 - 2200 . 

^1509001 

Tektronix measurement 
products are manufactured in 
ISO registered facilities. 



Features - Benefits 



500 MHz, 300 MHz, and 100 MHz 
Bandwidths 

Sample Rates up to 5 GS/s 
2 or 4 Channels 

Full VGA Color LCD on all Models 

Built-in Floppy Disk Drive For Easy 
Storage and Documentation 

Centronics Port Standard on ail 
Models for Quick, Convenient 
Hardcopies 

9-Bit Vertical Resolution 
Multi-Language User Interface 

QuickMenu User Interface Mode for 
Quick, Easy Operation 

Optional Modules for RS-232, GPIB, 
or VGA Communication Ports 

Advanced Triggers, such as. Glitch, 
Width, and Logic Standard on 
4 Channel Models 

Fast Fourier Transform (FFT) for 
Frequency and Harmonic Analysis 
Standard on 4 Channel Models 



Applications 



Telecommunications Manufacturing 
(Telecom Mask Test Application 
Module)*^ 

Digital Design and Debug 

Video Design and Service 
(Extended Video Application 
Module) 

Industrial Electronic Design 
Power Supply Design 

Connected Instrumentation 
(lOBaseT LAN*’, GPIB and VGA 
Modules with RS232) 

Highly Mobile Environments 
(Optional Battery Pack) 

New in January 2000, refer to the 
Tektronix web site or your local sales 
rperesentative for details. 



Extended Video Application 
Module, Provides Features, such as 
Custom Video Trigger, Line Count 
Trigger and NTSC, PAL, SECAM 
Display Graticules 

Support for Active Probes, 
Differential Probes, and Current 
Probes that Provide Automatic 
Scaling and Units 

Optional Battery Power for 
Convenient Use in the Field or 
Away from the Bench 



www.tektroiiix.coiiVMeasareneiit/scopes/ 



OSCILLOSCOPES 



95 






Digital Phosphor Oscilloscopes 

NEW TDS 3012 • TDS 3014 • TDS 3032 • TDS 3034 • TDS 3052 • TDS 3054 



The TDS 3000 Series of 
Digital Phosphor 
Oscilloscopes 

The TDS 3000 oscilloscopes are the 
lowest priced, most portable Digital 
Phosphor Oscilloscopes (DPOs). Now 
every design engineer and technician 
can take advantage of the tremendous 
benefits of DPOs. DPOs deliver a new 
level of insight that makes dealing with 
complex signals simple. DPOs display, 
store, and analyze, in real-time three 
dimensions of signal information: 
amplitude, time, and distribution of 
amplitude over time. 

BENEFITS OF DPO 

DPOs have an intensity graded color 
display that provides information 
about the frequency of occurrence of 
signal amplitudes and widths. This 
helps the user locate and characterize 
waveform anomalies that can be elu- 
sive on traditional Digital Storage 
Oscilloscopes. The fast update rate of 
DPOs also makes it easier to capture 
and display infrequent waveforms or 
waveform variations. 

QUICK TO LEARN AND QUICK TO USE 

The TDS 3000 Series graphical user 
interface offers a new operating mode 
called QuickMenu. This quick access 
user interface makes the main oscillo- 
scope controls accessible with a push 
of a single button. Included with every 
scope is an On-Line Tour disk that runs 
in the oscilloscope. This disk gives an 
overview of the product’s operation 
and capabilities. 

FLEXIBLE FEATURES FOR EVERY 
APPLICATION 

The portable form factor allows the 
instrument to go wherever it is needed. 
The Communication and Application 
Modules enable the instrument to be 
configured for specific applications or 
upgraded without returning it to the 
manufacturer. The TekProbe® Level II 
interface provides power to a range of 
application specific accessories. 

APPLICATION MODULES 

With the application module concept, 
the TDS 3000 Series can be easily adapt- 
ed to the needs of the user. These mod- 
ules can be easily installed by the user 
and the scope, upon power up indicates 



which modules are installed. Currently, 
there are three application modules 
available for the TDS 3000 Series — an 
FFT module, an advanced trigger mod- 
ule and an extended video module. In 
addition, there are twm communication 
modules available — a GPIB/RS-232 
module and a VGA/RS-232 module. 
Centronics port is standard. 

TDS3FFT - FFT MODULE 

When this module is installed in the 
TDS 3000 Series scope, the scope 
becomes an excellent troubleshooting 
aid for: 

► Testing impulse response of filters 
and systems. 

► Measuring harmonic content and 
distortions in systems. 

► Identifying and locating noise and 
interference sources 

► Analyzing vibration 

► Analyzing harmonics in 50 and 60 Hz 
power lines 

The TDS 3FFT application module pro- 
vides the following features 

► FFT Windows: Four FFT windows 
(Rectangular, Hamming, Hanning 
and Blackman-Harris) let you match 
the optimum window to the signal 
you are analyzing 

► Analyze repetive, single-shot and 
stored waveforms: An FFT waveform 
on any actively-acquired signal, last 
acquired signal or signal stored in the 
reference memory can be displayed 

► The FFT vertical graticule can be set 
to either dB or linear rms 

► The time signals and FFT waveforms 
can be shown on the display at the 
same time. This helps in the quick 
analysis of circuit or system problems 




TDS 3000 DPO answers today’s power 
measurement problems. 



TYPICAL APPLICATION FOR THE 
FFT MODULE 

In the design or analysis of power sup- 
plies, it is important to check the har- 
monics in the power supply’s load cur- 
rent. The following figure shows the 
harmonic analysis of a 250 watt class D 
power supply. Using the scope’s cur- 
sors, you can measure the frequency 
and magnitude of the individual fre- 
quency components. 

TDS 3TRG - ADVANCED TRIGGER 
MODULE 

When this module is installed in the 
TDS 3000 Series scope, an advanced 
trigger menu is added to the scope 
with the appropriate logic and pulse 
triggering capability. 

LOGIC TRIGGER FEATURES 

Logic triggering is extremely useful in 
the troubleshooting of digital circuits. 
The oscilloscope is triggered when two 
signals meet a Boolean trigger condi- 
tion. This module provides pattern and 
state logic trigger modes. 

Pattern Trigger. 

Pattern triggering triggers the oscillo- 
scope when two signals become logical- 
ly true or false. Basically, the pattern- 
triggering feature triggers the oscillo- 
scope from the output of a two-input 
AND, OR, NAND or NOR logic gate. 

You can specify time constraints and 
signal threshold levels as part of the 
triggering condition. The trigger is use- 
ful for digital logic troubleshooting. 

State Trigger. 

State triggering triggers the oscillo- 
scope when a state signal is true or 
false at the time a clock signal transi- 
tion is true. This trigger is useful for 
troubleshooting digital logic synchro- 
nous state machines. 

PULSE TRIGGER FEATURES 

Pulse triggering triggers the oscillo- 
scope when a signal meets a timing or 
threshold condition. The advanced trig- 
ger module provides three pulse trigger 
modes: pulse width, runt pulse and 
slew rate. 

Pulse Width (or Glitch). 

Pulse-width triggering triggers the oscil- 
loscope when a signalpulse width is les 
than, greater tlian, equal to or not equal 



96 



OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 



Digital Phosphor Oscilloscopes 

NEW TDS 3012 • TDS 3014 • TDS 3032 • TDS 3034 • TDS 3052 • TDS 3054 



to a specified pulse width, this trigger is 
useful for digital logic troubleshooting. 

Runt Pulse. 

Runt-pulse triggering triggers the oscil- 
loscope when a signal pulse is less than 
a specified threshold level. You can also 
specify runt pulse-width parameters. 
This ti’igger is useful for troubleshotting 
bus-contention problems. 

Slew Rate. 

Slew-rate triggering triggers the oscillo- 
scope when a signal’s slew rate (rise or 
fall time) is less than, greater than, 
equal to or not equal to a specified slew 
rate. This trigger is useful for trou- 
bleshooting digital bus transcievers, 
transmission lines and op-amp circuits. 

TDS 3VID - EXTENDED VIDEO 
MODULE 

All TDS 3000 Series oscilloscopes come 
standard with NTSC, PAL and SECAM 
(All Fields or All Lines) triggering capa- 
bility. The TDS 3VID application mod- 
ule extends this basic video triggering 
by adding the following features. 

Video QuickMenu. 

This Video QuickMenu function allows 
you to display a bottom and side menu 
that contains video functions useful for 
displaying and measuring broadcast 



standard waveforms, including trigger 
source, when to trigger, video graticule 
and video autoset. 

Video Autoset. 

The autoset function automatically 
adjusts the vertical, horizontal and 
video trigger settings to display a video 
waveform triggered on all lines and 
fields. You can then manually adjust 
controls to optimize the display. This 
function is available in the Video 
QuickMenu and in the Acquire menu. 

Custom Video. 

Using the custom video function allows 
you to specify custom horizontal scan 
rates in order to trigger on non-broad- 
cast video waveforms, such as those 
used by computer monitors and med- 
ical equipment displays. This following 
figure shows the TDS 3000 scope trig- 
gering on a scan rate of 26.2 kHz. 

Line Count Trigger. 

Sometimes it is necessary to view a 
single line of the video waveform. For 
example, the programming information 
in the NTSC signal is sometimes found 
on Line 20. Line Count triggering 
allows you to trigger on any particular 
line by scrolling through the line num- 
bers and selecting the one you want. 




Using the TDS 3000 DPO for video mainte- 
nance and service measurement. 



Field Holdoff. 

The field holdoff function provides the 
capability to specify a number of fields 
to wait before re-enabling triggering. 
This allows you to trigger on a single 
filed (e.g. field 1 or field 3 of NTSC) 
instead of both field 1 and field 3. 

Video Graticules. 

The video graticule function provides 
the capability for the user to change the 
standard oscilloscope graticule to either 
IRE or mV depending on the signal for- 
mat. Video graticules make it easier to 
measure and analyze video waveforms. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPES 97 





Digital Phosphor Oscilloscopes 

NEW TDS 3012 • TDS 3014 • TDS 3032 • TDS 3034 • TDS 3052 • TDS 3054 



Characteristics 



TDS 3000 Series Electrical Characteristics 





TDS 3012 


TDS 3032 


TDS 3052 


TDS 3014 


TDS 3034 


TDS 3054 


Bandwidth 


100 MHz 


300 MHz 


500 MHz 


100 MHz 


300 MHz 


500 MHz 


Channels 


2 


2 


2 


4 


4 


4 


Sample Rate on Each Channel 


1.25 GS/s 


2.5 GS/s 


5 GS/s 


1.25 GS/s 


2.5 GS/s 


5 GS/s 


Maximum Record Length 






lOK points on all models 






Vertical Resolution 






9-bits on all models 






Vertical Sensitivity (/div) 






1 mV- 10 V on all models 






Vertical Accuracy 






±2% on all models 






Max Input Voltage (1 MO) 






150V RMS CAT 1 on all models 






Position Range 






± 5 div on all models 






BW Limit 


20 MHz 


20 , 150 MHz 


20, 150 MHz 


20 MHz 


20 , 150 MHz 


20, 150 MHz 


Input Coupling 






AC, DC, GND on all models 






Input Impedance Selections 






I MQ in parallel V 


/ith 13 pF, or 50 Q. 






Time BaseiRange (/div) 


4 ns - 10 s/div 


2 ns - 10 s/div 


1 ns - 10 s/div 


4 ns - 10 s/div 


2 ns - 10 s/div 


1 ns - 10 s/div 


Accuracy 


200 ppm 


200 ppm 


200 ppm 


200 ppm 


200 ppm 


200 ppm 


Display Monitor Color LCD 



ACQUISITION MODES TRIGGER TYPES MEASUREMENT SYSTEM 



Peak Detect - High frequency and random 
glitch capture. Captures glitches as narrow 
as 1 ns. 

Sample - Sample data only. 

Envelope - Max/Min values acquired over 
one or more acquisitions. 

Average - Waveform data from 2 to 572 
(selectable) acquisitions is averaged. 

Single Sequence - Use SINGLE SEQUENCE 
button to capture a single triggered acquisition 
sequence at a time. 

TRIGGER SYSTEM 

Main Trigger Modes - Auto (supports Roll 
Mode for 40 ms/div and slower), Normal. 

B Trigger - Trigger after time or events. 

Trigger After Time Range - 13.2 ns to 50 s. 
Trigger After Events Range - 1 to 9,999,999 
events. 

External Trigger Input (available on TDS 
30 X 2 only) - >1 MQ in parallel with 17 pF; 
Max input voltage is 150V RMS. 



Edge - Conventional level-driven trigger. 
Positive or negative slope on any channel. 
Coupling selections: DC, noise reject, HF reject, 
LF reject. 

Video - Trigger on all lines, odd/even, or all 
fields. See TDS 3VID for Extended Video trig- 
gering and measurement features. 

Logic - (Standard on TDS 30X4, must pur- 
chase TDS 3TRGfor TDS 30X2) 

PAHERN: Specifies AND, OR, NAND, NOR 
when true or false for a specific time. 

STATE: Any logic state. Triggerable on rising or 
falling edge, of a clock. 

Note: Logic triggers can only be used on com- 
binations of 2 inputs. 

Pulse - (Standard on TDS 30X4, must pur- 
chase TDS 3TRGforTDS 30X2) 

WIDTH (or GLITCH): Trigger on pulse width 
less than, greater than, equal to, or not equal 
to a selectable time limit ranging from 39.6 ns 
to 50s. 

RUNT: Trigger on a pulse that crosses one 
threshold but fails to cross a second threshold 
before crossing the first again. 

SLEW RATE: Trigger on pulse edge rates that 
are either faster or slower than a set rate. 
Edges can be rising, falling, or either. 



Automatic Waveform Measurements - 

Period, Frequency, +Width, -Width, Rise Time, 
Fall Time, +Duty Cycle, -Duty Cycle, 
+Overshoot, -Overshoot, High, Low, Max, Min, 
Pk-Pk, Amplitude, Mean, Cycle Mean, RMS, 
Cycle RMS, Burst Width. 

Display any four measurements from any com- 
bination of waveforms. 

Thresholds - Settable in percentage or voltage. 
Gating - Measurements can be gated using 
the screen or vertical cursors. 

WAVEFORM PROCESSING 
Deskew - Channel to channel deskew ±10 ns 
may be manually entered for better timing 
measurements and more accurate math wave- 
forms. 

Arithmetic Operators - Add, Subtract, 
Multiply, Divide. 

Autoset - Single-button, automatic setup on 
selected input signal for vertical, horizontal, 
and trigger systems. 

DISPLAY CHARAaERISTICS 
Graticules - Full, grid, cross-hair, frame, 

NTSC, PAL and SECAM (with TDS 3VID option- 
al application module). 

Format - YT and XY. 



98 



OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 




Digital Phosphor Oscilloscopes 

NEW TDS 3012 • TDS 3014 • TDS 3032 • TDS 3034 • TDS 3052 • TDS 3054 



I/O INTERFACE 
Hardcopy Port (standard) - 

Centronics-type parallel. 

TDS 3GM Communications Module - 

GPIB (IEEE -488.2) Programmability: Full 
talk/listen modes; Control of all modes, set- 
tings, and measurements. 

RS-232-C Interface Programmability: Full 
talk/listen modes; Control of all modes, set- 
tings, and measurements. Baud Rate up to 
38,400. DB-9 male connector. 

Includes WaveStar™ Software for oscilloscopes 
30-day, full-functioning product demo. 
Programmer Manual: (071-0381-00). 

Note: For Ethernet/LAN connection use this 
module with the AD007 GPIB to LAN adapter. 
TDS 3VM Communications Module - 
VGA: Monitor output for direct display on 
large VGA-equipped monitors. DB-15 female 
connector, 31.6 kHz sync rate, EIA RS-343A 
compliant. 



RS-232-C Interface Programmability: same as 
TDS 3GM. 

Includes WaveStar™ Software for oscilloscopes 
30-day, full-functioning product demo. 
Programmer Manual: same as TDS 3GM. 
Note: Only one Communication Module may 
be installed at a time. 

HARD COPY CAPABILITY 
Graphics File Formats - Interleaf (.img), TIF, 
PCX (PC Paintbrush), BMP (Microsoft 
Windows), and Encapsulated Postscript (EPS). 
Printer Formats - Thinkjet, DeskJet, LaserJet, 
Epson (9 and 24 pin). 

ENVIRONMENTAL AND SAFETY 
Temperature - +5 to +50®C (operating), -20 
to +60°C (nonoperating). 

Humidity - 20% to 80% RH below 32®C, der- 
ate to 30% RH at 45°C (operating), 5% to 90% 
RH below 41X derate to 30% RH at 60®C 
(nonoperating). 



Altitude - to 3,000 m (operating), 15,000 m 
(nonoperating). 

Electromagnetic Compatibility - Meets or 
exceeds EN55011 Class A Radiated and 
Conducted Emissions; EN50082-1; FCC 47 CFR, 
Part 15, Subpart B, Class A; Australian EMC 
Framework; Russian GOST EMC regulations. 
Safety - UL3111-1, CSAIOIO.I, EN61010-1, 
IEC61010-1. 

Physical Characteristics 



Dimensions mm In. 



Width 


375.0 


14.8 


Height 


17^ 


6.9 


Depth 


149.0 


5.9 




kg 


Lbs. 


Instrument Only 


3.2 


7.0 


W/ battery 


5.2 


11.5 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPES 



99 



Digital Phosphor Oscilloscopes 

NEW TDS 3012 • TDS 3014 • TDS 3032 • TDS 3034 • TDS 3052 • TDS 3054 











TDS 3FFT - Application Module being TDS 3BAT - Battery Pack being installed, 

installed. 



Ordering Information <> 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



TDS 3012, TDS 3014, TDS 3032, TDS 3034, 

TDS 3052, TDS 3054 

STANDARD ACCESSORIES 

Probes: 2 each P3010 lOX passive probes (TDS 3012), 
4 each P3010 lOX passive probes (TDS 3014), 2 each 
P6139A lOX passive probes (TDS 3032, TDS 3052), 

4 each P6139A lOX passive probes (TDS 3034, 

TDS 3054). 

Documentation: Quick Reference Manual, User 
Manual, On-line Tour Disk, Front panel overlay for 
non-English languages. 

Application Modules (TDS 3014, TDS 3034, TDS 3054 
only): TDS 3FFT, TDS 3TRG. 

Power Cord. 

Accessory Tray. 

Protective Front Cover: has holder for reference 
manual and/or 3.5 in. floppy disks. 

NIST-Traceable Certificate of Calibration. 

WARRANTY INFORMATION 

Three year warranty covering ail labor and parts, 
excluding probes. 

INTERNATIONAL POWER PLUGS 
Standard - US (161-0104-00). 

Opt. A1 - Universal Euro 220V, 50 Hz (161-0104-06). 
Opt. A2 - United Kingdom 240V, 50 Hz (161-0104-07). 
Opt. A3 - Australia 240V, 50 Hz (161-0104-05). 

Opt. A5 - Switzerland 220V, 50 Hz (161-0167-00). 
Opt. A6 - Japan 3 to 2 wire adapter (013-0310-00). 
See page 619 for description. 



INTERNATIONAL USER MANUALS (TDS 3000 
SERIES, TDS 3FFT, TDS 3TRG, TDS 3VID) 
Standard - English. 

Opt. Li - French. 

Opt. L2 - Italian. 

Opt. L3 - German. 

Opt. L4 - Spanish. 

Opt. L5 - Japanese. 

Opt. L6 - Portuguese. 

Opt. L7 - Simplified Chinese. 

Opt. L8 - Traditional Chinese. 

Opt. L9 - Korean. 

Opt. LR - Russian. 

INSTRUMENT ACCESSORIES 

TDS STMT - Telecom Mask Test Module*'. 

TDS 3FFT - FFT Application Module (standard on 
TDS 30X4). Adds FFT measurement capabilities in dB 
or linear RMS scales. A selection of four FFT win- 
dows (Rectangular, Hamming, Hanning, and 
Blackman-Harris) are provided. 

TDS 3TRG - Advanced Trigger Application Module 
(standard on TDS 30X4). Adds Logic and Pulse trig- 
gering described under Trigger Types (page 2). 

TDS 3VID - Extended Video Application Module. 
Adds line count triggering, custom video scan and 
field rates, readout in mV or IRE units, and includes 
75 Q terminator. 

TDS 3EM - lOBaseT Ethernet (LAN) and RS-232 
interfaces*'. 

TDS 3GM - GPIB and RS232 interfaces. 

TDS 3VM - VGA port and RS232 interface. 

TDS 3BAT - Battery pack for up to 2 hours continu- 
ous operation without line power. Note: the instru- 
ment must be grounded at all times. 

013-0278-00 - Video Clamp Pod. 

*’Ne\vin Januarx' 2000. refer to the Tektronix web 
site or your local sales representative for details. 



TDS 3CHG - Fast charger for battery pack. 

AC3000 - Soft case for carrying instrument. 
RM3000 - Rackmount kit. 

Service Manual (TDS 3000 Series) - English Only 
(071-0382-00). 

TDS 3GM and TDS 3VM Programmers Manual - 

English Only (071-0381-00). 

WSTRO - WaveStar™ Software for Oscilloscopes, 
Windows 95/98/NT Application. 

PROBES 

ADA400A - lOOX, lOX, IX, 0.1 X High gain differen- 
tial amplifier. 

P6243 - 1 GHz, <lpF input C lOX active probe. 
P6246 - 400 MHz differential probe. 

P5205 - 1.3 kV, 100 MHz high voltage differential 
probe. 

P5210 - 5.6 kV, 50 MHz high voltage differential 
probe. 

P5I00 - 2.5 kV, lOOX high voltage passive probe. 
TCP202 - 15 A, DC + Peak AC 50 MHz AC/DC cur- 
rent probe. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

Product(s) available through your local Tektronix 
Distributor listed in the back of this catalog. 



jg ISO 9001 

Tektronix measurement products are manufactured 
in ISO registered facilities. 



100 OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 




Digital Storage Oscilloscopes 

TDS 210 • TDS 220 • New TDS 224 




Features - Benefits 



60 MHz or 100 MHz with 1 GS/s 
Sample Rate on all Channels 

2 and 4 Channel Models 
Dual Timebase 
Automatic Measurements 
Multi-language User Interface 
Autoset 

Waveform and Setup Memories 

Extended Capabilities Are Provided 
with Optional Modules, Software 
and Probing 



Applications 



Design/Debug 
Sen/ice and Repair 

Manufacturing Test and Quality 
Control 

Education/Training 



Product(s) available through 
your local Tektronix Distributor 
listed in the back of this catalog. 

C€ 

ISO 9001 

Tektronix measurement 
products are manufactured in 
ISO registered facilities. 




Product(s) complies with IEEE 
standard 488.1-1987, RS-232-C, 
and with Tektronix Standard 
Codes and Formats. 



Tektronix' Most Popular DSO 

The TDS 200 Oscilloscopes have quickly become 
the benchmark for low-cost oscilloscopes. 
Offering an unbeatable combination of perform- 
ance, reliability and versatility, the TDS 200 
Series offers breakthrough digital and real-time 
advantages at low-cost analog oscilloscope 
prices. And with the introduction of the TDS 
224, Tektronix now brings the digital perform- 
ance of the TDS 200 to customers that need four 
full-featured channels. 

AFFORDABLE DIGITAL PERFORMANCE 

No other digital oscilloscope offers as much 
bandwidth and sample rate for the price. By 
sampling at 10 and 16 times their band widths on 
all channels, the TDS 200 Series oscilloscopes 
provide accurate real-time acquisition up to their 
full bandwidth. 

VERSATILITY AND FLEXIBILITY 

The portable form factor provides increased ver- 
satility, allowing the instrument to be easily 
moved or safely stored away when not in use. 

EASY TO USE 

The user interface is similar to that of an analog 
oscilloscope, but with improvements that reduce 
learning time and increase efficiency. 



THE PERSONAL OSCILLOSCOPE 

The TDS 200 Series oscilloscopes are designed 
for people who demand the ultimate in oscillo- 
scope value. If an inexpensive yet high perform- 
ance oscilloscope is needed for the bench, pro- 
duction line, or training lab, a TDS 200 Series 
Oscilloscope is the best choice. 



Characteristics 



SIGNAL ACQUISITION SYSTEM 
Bandwidth - 

TDS 210: 60 MHz. 

TDS 220: 100 MHz. 

TDS 224: 100 MHz. 

Sample Rate - 1 GS/s on each channel. 

Channels - 

TDS 210 and TDS 220: 2 identical channels plus external 
trigger. 

TDS 224: 4 identical channels. 

Sensitivity (with calibrated fine adjustment) - 

2 mV to 5 V/div (bandwidth limited to 20 MHz at 2 
mV/div and 5 mV/div, in all modes, and 20 MHz at 10 
mV/div in Peak Detect mode). 

Vertical Zoom - Vertically expand or compress a live or 
stopped waveform. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPES 101 








Digital Storage Oscilloscopes 

TDS 210 • TDS 220 • NEW TDS 224 



Calibrated Position Range 

Volts/Piv Setting Offset Range 



2 mV to 200 mV/div 


±2V 


>200 mV to 5 V/div 


+50 V 



DC Gain Accuracy - ± 3%. (± 4% at 2 

mV/div and 5 mV/div). 

Vertical Resolution - 8 bits (256 levels over 
10.24 vertical divisions). 

AUTOMATIC MEASUREMENTS 

Period, Frequency, Cycle RMS, Mean, 

Peak to Peak. 

ACQUISITION MODES 
Sample, Average, Peak Detect - High fre- 
quency and random glitch capture; captures 
glitches as narrow as 10 ns using acquisition 
hardware at all time/div settings between 5 
ps/div and 5 s/div. 

TIME BASE SYSTEM (MAIN AND 
WINDOW) 

Horizontal Zoom - Horizontally expand or 
compress a live or stopped waveform. 
Time/Division Range - 5 ns to 5 s/div. 
Record Length - 2500 sample points 
per channel. 

Horizontal Accuracy - ± 0.01%. 

NON-VOLATILE STORAGE 

Waveform Display - Two 2500 point reference 

waveforms. 

Waveform Storage - Two 2500 point refer- 
ence waveforms (TDS 210, TDS 220), four 2500 
point reference waveforms (TDS 224). 

Setups - 5 front panel setups. 

TRIGGERING SYSTEM (MAIN ONLY) 
Trigger Type - Edge (Rising or Falling), Video, 
Set to 500/0. 

Video Trigger Type - Triggers on Fields or 
Lines from composite video; triggers on broad- 
cast standard NTSC, PAL, or SECAM video. 



Trigger Modes - Auto, Normal, Single Sweep. 

Trigger Source - 

TDS 210 and TDS 220: CHI, CH2, Ext, Ext/5 and 
AC Line. 

TDS 224: CHI, CH2, CH3, CH4 and AC Line. 
Trigger View - Displays trigger signal while 
trigger view button depressed. 

CURSORS 

Types - Voltage, Time. 

Measurements - [A]T, 1/[A]T, [A]V. 

WAVEFORM PROCESSING 
Arithmetic Operators - Add, Subtract. 
Sources - CH1±CH2, CH3±CH4 (TDS 224). 
Autoset - Single button automatic setup on 
selected input signal for vertical, horizontal, 
and trigger systems. 

DISPLAY SYSTEM 

Robust, backlit LCD with adjustable multilevel 
contrast. 

Interpolation - Sin(x)/x. 

Dispiay Modes - Vectors, dots. 

Persistence - Off, 1 sec, 2 sec, 5 sec. Infinite. 
Format - YT and XY. 

HARDCOPY CAPABILITY (REQUIRES 
MODULES) 

Printer/File Formats - Thinkjet, Deskjet, 
Laserjet, Epson (9 or 24 pin), BMP, PCX, IMG, 
EPS, DPU 411, DPU 412. 

Hardcopy Layout - Landscape or Portrait. 

TDS 2CM COMMUNICATIONS 
EXTENSION MODULE 
Centronics-type Parallel Port 
RS-232 Programmability - Full talk/listen 
modes. Control of all modes, settings, and meas- 
urements. Baud Rate up to 19,200. 9-Pin, DTE. 
GPIB Programmability - Full talk/listen 
modes. Control of all modes, settings, and 
measurements (IEEE Std 488-1987). 



Includes WaveStar™ Software for Oscilloscopes 
30 day product demo. 

TDS 2MM MEASUREMENT EXTENSION 
MODULE 

FFT - Windows: Hanning, Flat Top, Rectangular. 
Sample points: 2048. 

Automatic Measurements - Rise/Fall Time, 
Positive/Negative Pulse Width. 

Interface - Centronics, RS-232, GPIB. 

ENVIRONMENTAL AND SAFETY 
Temperature - 

Operating: 0°C to +50°C. 

Nonoperating: -20°C to +60®C. 

Humidity - 

Up to 90% RH at or below +40°C; 

Up to 60% RH from 41 °C to 50®C (Operating 
and Nonoperating). 

Altitude - 

Up to 3000 m (Operating). 

Electromagnetic Emissions - 

Meets Directive 89/336/EEC for 
Electromagnetic Compatibility; 

FCC Code of Federal Regulations, 47 CFR, Part 
15, Subpart B, Class A. 

Safety - UL3111-1, CSAIOIO.I, IEC61010-1, 
EN61010-1. 

Physical Characteristics 

Dimensions mm in. 



Width 


304.8 


12.0 


Height 


151.4 


5.96 


Depth 


120.7 


4.75 


Weight 


kg 


lb. 


oscilloscope only 


1.5 


3.25 


w/accessories 


1.7 


3.75 



102 



OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 



Digital Storage Oscilloscopes 

TDS 210 • TDS 220 • NEW TDS 224 



your local Tektronix representative, inside the U.S. see 



Ordering Information 



For price information: Outside the U.S. contact 

TDS 210 

Digital Storage Oscilloscopes. 

TDS 220 

Digital Storage Oscilloscopes. 

TDS 224 

Digital Storage Oscilloscopes. 

EACH INCLUDE: 

P6112 100 MHz lOX Passive Probes (one per channel). 

WARRANTY INFORMATION 

Three year warranty covering all labor and parts, 
excluding probes. 

INTERNATIONAL POWER PLUGS 
Standard - U.S. 115 V, 60 Hz (161-0230-01). 

Opt. A1 - Universal Euro 220 V, 50 Hz (161-0104-06). 
Opt. A2 - United Kingdom 240 V, 50 Hz (161-0104-07). 
Opt. A3 - Australia 240 V, 50 Hz (161-0104-05). 

Opt. A4 - North America 240 V, 60 Hz (161-0104-08). 
Opt. AS - Switzerland 220 V, 50 Hz (161-0167-00). 
Opt. AC - China 240 V, 50 Hz (161-0306-00). 

See page 619 for description. 

INTERNATIONAL USER MANUALS (TDS 200 
SERIES OSCILLOSCOPES) 

Standard - English (071-0398-00). 

Opt. LI - French (071-0400-00). 

Opt. L2 - Italian (071-0401-00). 

Opt. L3 - German (071-0402-00). 

Opt. U - Spanish (071 -0399-00). 

Opt. L5 - Japanese (071-0405-00). 

Opt. L6 - Portuguese (071-0403-00). 

Opt. L7 - Simplified Chinese (071-0406-00). 

Opt. L8 - Traditional Chinese (071-0407-00). 

Opt. L9 - Korean (071-0408-00). 

Opt. LR - Russian (071-0404-00). 

Translated front panel overlays Included with their 
respective user manuals (except Russian). 



INTERNATIONAL USER MANUALS (TDS 2XM 
EXTENSION MODULES) 

Standard - English (071-0409-00). 

Opt. LI - French (071-0483-00). 

Opt. L2 - Italian (071-0484-00). 

Opt. L3 - German (071-0485-00). 

Opt. L4 - Spanish (071-0482-00). 

Opt. L5 - Japanese (071-0488-00). 

Opt. L6 - Portuguese (071-0486-00). 

Opt. L7 - Simplified Chinese (071-0489-00). 

Opt. L8 - Traditional Chinese (071-0490-00). 

Opt. L9 - Korean (071-0491-00). 

Opt. LR - Russian (071-0487-00). 

INSTRUMENT ACCESSORIES 

TDS 2CM - Communications Extension Module. 

(I/O Cable not included) 

TDS 2MM - Measurement Extension Module. (I/O 
Cable not included) 

TR210 - Huntron Tracker. 

AD007 - LAN/WAN GPIB Converter. 

AC220 - Soft Carrying Case. 

RM200 - Rackmount Kit. 

Service Manual (TDS 200 Series) - English only 
(071-0492-00). 

TDS 2CM and TDS 2MM Programmer's 
Manual - English only (071-0493-00). 

SOFTWARE 

WSTRO - WaveStar™ Software for Oscilloscopes, 
Windows 95/98/NT application for waveform capture, 
analysis, documentation and control from your PC. 
WSTROU - Upgrade from WSTR31 to WSTRO. 
WSTR31 - WaveStar™ software for Windows 3.1. 
(TDS 210, TDS 220). 



the price list in the back of this catalog. 

PROBES 

P6015A - lOOOX High Voltage Probe. 

P6021 - 60 MHz AC Current Probe. 

P6022 - 120 MHz AC Current Probe. 

A621 - 2000 A AC Current Probe/BNC. 

A622 - 100 A AC/DC Current Probe/BNC. 

P5100 - lOOX High Voltage Passive Probe. 

P5200 - High Voltage Differential Probe. 

P6101B - IX Passive Voltage Probe (15 MHz). 
P6243S - Active FET Probing System (1 GHz). 
P6408 - Word Recognizer/Trigger Probe. 

P6561A - SMD Small Geometry Probe. 

AM503S - AC/DC Current Probe System. 

ACCESSORY CABLES 

GPIB, 1 m (3.3 ft) - Order 012-0991-01. 

GPIB, 2 m (6.6 ft) - Order 012-0991-00. 

RS-232, 9-Pin female to 9-Pin male connectors, 
15 ft. (4.6 m), for modems - Order 012-1241-00. 
Centronics, 25-Pin maie to 36-Pin Centronics, 
2.4 m (8 ft), for paraiiel printer interfaces - 

Order 012-1214-00. 

Product(s) available through your local Tektronix 
Distributor listed in the back of this catalog. 

CC 

jgisosooi 

Tektronix measurement products are manufactured 
in ISO registered facilities. 




Product(s) complies with IEEE Standard 488.1-1987, 
RS-232-C, and with Tektronix Standard Codes and Formats. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPES 103 




Handheld Battery Operated 
Oscilloscope/DMM/Power Analyzers 

TekScope® THS 730A • THS 720A • THS 710A • THS 720P 




Features - Benefits Applications 



THS 730A/THS 720A/THS 
710A/THS 720P 

200, 100 and 60 MHz Bandwidth 

1 CS/s, 500 MS/s, 250 MS/s 
Sampling Rates per Channel 

Two Channels and Dual Digitizers 
External Trigger 

3-3/4 Digit DMM with Datalogger 
Roll Mode 

Extra Bright Backlit Display 
8 ns Glitch Capture 

Independently Floating Isolated 
Scope and DMM Channels for Safety 

Advanced Trigger - Delay, Pulse 
and Video (Line Count and Field 
Select), PWM Motor Drive (THS 720P) 

NiCd Battery and AC Adapter 
21 Automatic Measurements 

RS-232 Programmability/ 
Communications 

Deluxe Soft Carrying Case 

THS 720P ONLY 

Measures Harmonics up to 31st 
(Fundamental from 30 Hz to 450 Hz) 

Automatic Power Measurement 
with Statistics 

Full Floating Measurement 
Capability up to 600 Vrms 

1 kV High-voltage Probes 



Field or Bench Electronic 
Troubleshooting 

Floating (Non-grounded) system 
Measurements 

Industrial Electronic Equipment 
Troubleshooting (THS 720P) 

Power Quality Surveys (THS 720P) 



Product(s) available through 
your local Tektronix Distributor 
listed in the back of this catalog. 






C€ 

155OT1 



Tektronix measurement 
products are manufactured in 
ISO registered facilities. 



THS 700 Series 

The TekScope THS 700 Series Scope/DMM com- 
bines a full-featured real-time oscilloscope with 
a True RMS digital multimeter in rugged, bat- 
tery-operated instruments. Scope and meter 
modes can operate simultaneously and inde- 
pendently on the same or separate signals. The 
high-resolution, backlit display and pop-up 



menus make it easy for users to take full advan- 
tage of the instrument’s many features. These 
include cursors, video trigger, voltage and resist- 
ance measurements, and storage of waveforms, 
data and instrument setups. In addition, they 
offer the most comprehensive triggering capabil- 
ities - external trigger and extensive triggering 
including delay, pulse width and video. 



104 OSCILLOSCOPES 



www.tektronix.com/Measurefflent/scopes/ 






Handheld Battery Operated Oscilloscope/DMM/Power Analyzers 

TEKSCOPE^ THS 730A • THS 720A * THS 710A • THS 720P 



The THS 700A Series is ideal for elec- 
tronic applications - at the bench or at 
the site. 

The THS 700A Series shares measure- 
ment features with the THS 7 2 OP 
Scope/DMM which includes features to 
address the needs of electric/power 
electronics measurements. 

The Only Safe Measurement 
Solution for Power 
Electronics 

The THS 720P TekScope 
IsolatedChanneP” Scope/DMM is ideal for 
electric/power electronics applications. 

The THS 720P includes features specifi- 
cally for electric/power electronics meas- 
urements which allow testing and verify- 



ing correct operation of motors, checking 
transformer efficiency, verifying power- 
supply performance, and measuring the 
effect of neutral current. These features 
include harmonic analysis, power meas- 
urements and statistics and PWM motor 
drive triggering. It also contains the pow- 
erful features of a modem oscilloscope 
that enable troubleshooting and verifica- 
tion of complicated electronic control 
circuits controlling the high-voltage 
power-electronics circuitry. 




THS 720P 



Characteristics 



Oscilloscope Functions 

THS 730A 


THS 720A 


THS 710A 


THS 720P 


Bandwidth 


200 MHz 


100 MHz 


60 MHz 


100 MHz 


Sample Rate (Each Channel) 


1 GS/s 


500 MS/s 


250 MS/s 


500 MS/s 


Time/Division Range 


2 nsto 50s/div 


5 nsto 50s/div 


10 ns to 50s/div 


5 nsto 50s/div 


Power Measurements 


N 


N 


N 


Y 



OSCILLOSCOPE FUNCTIONS 
Channels - Two. 

Sensitivity - 5 mV to 50 V/div (to 500 V/div 
with lOX probe). 

Position Range - ±10 div. 

DC Gain Accuracy - ± 2 %. 

Verticai Resoiution - 8-Bits. 

Record Length - 2500 points. 

Horizontai Accuracy - ±200 ppm. 

Roii Mode - > 0.5 s/div. 

Autorange - User-selectable. 

Trigger Modes - Auto, Normal. 

Trigger Types - Edge, Pulse, Video, External, 
Motor (THS 720P). 

Video Trigger Formats and Fieid Rates - 

Odd field, even field and line. 

Motor Trigger (THS 720P oniy) - Triggers 
on 3- and 5-level pulse-width modulated 
power signal. 

Externai Trigger Input - 5 MHz TTL 

compatible. 

Harmonics (THS 720P oniy) - Up to 31st 
(30 Hz-450 Hz). 

Waveform Processing - Add, Subtract, 
Multiply, Calculate Watts = V x I. 

Waveform Storage - 10 waveforms. 



Acquisition Modes - Sample, Envelope, 
Average, Peak Detect. 

Cursor Measurements - A Volts, A Time, 
1/ATime (Hz), Degree (phase). 

Cursor Types - Horizontal Bars, Vertical Bars, 
Paired (volts @ time). 

Dispiay System - Interpolation; Sin(x)/x. 
Format: YT and XY. 

Mode: Vector, Dot, Vector Accumulate, Dot 
Accumulate. 

Automatic Measurements 



+Width 


-Width 


Rise Time 


Fall Time 


+Duty Cycle 


-Duty Cycle 


+Overshoot 


-Overshoot 


High _ 


Max 


Low 


Min 


Peak-to-Peak 


Amplitude 


Mean 


RMS 


Cycle Mean 


Cyde RMS, 


Burst Width 



Power Measurements 
(THS 720 P only) - 

W True power 



VA Apparent power 


VAR 


Reactive power 


V 


Volts (RMS, Peak) 


A 


Amps (RMS, Peak) 


THD-F 


Total harmonic distortion 
as a percentage of the fundamental 


THD-R 


Total harmonic distortion 
of the RMS of the input signal 


PF 


Power factor 


DPF 


Displacement power factor 


PHI 


Phase difference between 
the voltage and current 



DMM SPECIFICATIONS 
DC Voltage Ranges - 400.0 mV to 880 V. 

DC Volts Accuracy - ±(0.5% of reading 
+ 5 counts). 

True RMS AC Voltage Ranges - 400.0 mV 
to 640 V. 

Maximum Float Voltage - 600 VRMS CAT li, 
each channel (probe dependent). 

Resolution - 4000 count, 3-3/4 digits. 

AC Volts Accuracy - ±(2% of reading 
+ 5 counts). 

Resistance Ranges - 400.0 Q. to 40.00 MQ. 
Resistance Accuracy - ±(0.5% of reading + 2 
counts); 40 ML2: ±(2% of reading + 5 counts). 
Diode Test Range - 0 to 2 V. 

Continuity Check - Audible tone when < 50 Q.. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPES 105 





Handheld Battery Operated Oscilloscope/DMM/Power Analyzers 

TEKSCOPE* THS 730A • THS 720A • THS 710A • THS 720P 



Modes - Min, Max, delta, Max-Min, Avg, Hold. 

Non-volatile Storage - 10 DMM screenshots. 
External Trigger Input - 5 MHz TTL 

compatible. 

Vertical Zoom Capability - 2X, 5X, 10X. 
dB Scale - Selectable, referenced from 1 mV 
to 10 V. 

dBm Scale - Selectable, referenced from 
50 il to 600 Q. 



GENERAL SPECIFICATIONS 
Setups - 10 front-panel setups. 

Safety - UL311H, CSAIOIO.I, EN61010-1. 
Power - NiCd rechargeable battery pack with 
AC adapter (both included). 

Battery Life - Approx. 2 hours from full 
charge. 

Display - Backlit LCD. 

Display Resolution - 320 x 240. 



Physical 


Characteristi 


ICS 


Dimensions 


mm 


in. 


Width 


177 


6.95 


Height 


217 


8.53 


Depth 


51 


2 


Weight 


H 


lbs. 


Net 


1.45 


3.2 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



THS 730A THS 720A, THS 710A 

Handheld Battery Operated Oscilloscopes/DMM. 
Includes: Two P61 17 10X Passive Probes, User 
Manual, Quick Reference Manual, Standard Meter 
Lead Set, NiCd Rechargeable Battery Pack, AC Power 
Adapter, Soft Carrying Case, Cable and Adapters for 
RS-232, NIST-traceable Certificate of Calibration. 

THS 720P 

Handheld Battery Operated Oscilloscope. 

Includes: Two P5102 lOX High-voltage Passive 
Probes, User Manual, Quick Reference Manual, 
Standard Meter Lead Set, NiCd Rechargeable Battery 
Pack, AC Power Adapter, Soft Carrying Case, Cable 
and Adapters for RS-232, NIST-traceable Certificate 
of Calibration. 

LANGUAGE OPTIONS 

Opt LI - French User Manual. 

Opt L2 - Italian User Manual. 

Opt L3 - German User Manual. 

Opt L4 - Spanish User Manual. 

Opt L5 - Japanese User Manual. 

Opt L6 - Portuguese User Manual. 

Opt L7 - Simplified Chinese User Manual. 

Opt L8 - Traditional Chinese User Manual. 

Opt L9 - Korean User Manual. 



INTERNATIONAL POWER PLUGS 
Opt. A1 - European power plug. 

Opt. A2 - UK power plug. 

Opt. A3 > Australian power plug. 

Opt. A6 - Japanese power plug. 

See page 619 for description. 

RECOMMENDED ACCESSORIES 

Also see page 495. 

P5102 - lOX 100 MHz Passive Probe for higher volt- 
age application: IOOOVr^s Tip-to-reference; 600 Vrms 
R eference-to-earth Ground (float). 

A621, A622 - Current Probes for scope operation. 
P6117 (replacement) - 10X Passive Probe. 

Battery Charger - Order THS 7CHG. 
Rechargeable Battery (replacement) - Order 
THS 7BAT. 

Hard Carrying Case - Order THS 7HCA. 

Standard Meter Lead Set (replacement) - Order 
012-1482-00. 

Deluxe Meter Lead Set - Order ATLDX1. 
Programming Manual - Order 070-9751-00. 
Service Manual - Order 070-9752-00. 

Soft Carrying Case (replacement) - Order 
016-1399-01. 



SOFTWARE 

WSTRO - WaveStar “ software for Oscilloscopes, 
Windows 95/98/NT application for waveform capture, 
analysis, documentation and control from your PC. 
WSTROU - Upgrade from WSTR31 to WSTRO. 
WSTR31 - WaveStar™ software for Windows 3.1. 

WARRANTy 

Three years (excluding probes). 

Product(s) available through your local Tektronix 
Distributor listed in the back of this catalog. 

CC 

ag ISO 9001 



Tektronix measurement products are manufactured 
in ISO registered facilities. 



106 



OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 




Handheld Oscilloscope Accessories 

PROBES • BATTERY CHARGER • HARDCASE 




P6117 Standard with the THS 710A, THS 
720A, and TH730A. 




P5102 Standard with the THS 720P. 



PROBES FOR THE THS 700 SERIES 

Passive Voltage Probes Standard with the 

THS 700 Series. Safety - UL3111-1, CSAlOlO.l, EN61010-1, EN61010-2-031. 




Probe 


Cable 

Length 


Bandwidth 


Attenuation 


Comp. 

Range 


Input C 


System 

Input resistance 


Maximum 

input 


Scopes 


P6H7*' 


2 m 


200 MHz 


lOX 


15 to 35 pF 


13.3 pF 


10.0 MO 


300 V RMS 


THS 710A/ 
720A/730A 


P5102*' 


2 m 


100 MHz 


lOX 


24 to 28 pF 


11.2 pF 


5.0 MO 


1000 V RMS 


THS 720P 
(only) 



Both of these probes can be used with any of the THS 700 Series Scopes. This only designates that these probes come standard with the scopes. 



THS7CHG TEKSCOPE BATTERY 
CHARGER 

► 12 to 18 volt input (DC) 

► 2 hour charge time 



THS7HCA TEKSCOPE HARD 
CARRYING CASE 

► Holds TekScope oscilloscope and 
accessories 



THSBAT NICAD BATTERY PACK 

► 4.8 volt 

► 2.8 A/hour 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPES 107 



Handheld Oscilloscope Accessories 

PROBES • BATTERY CHARGER • HARDCASE 



General Purpose Current 
Probes 

► Clamp-on 

► Excellent value 

► AC and DC 

► Easy to use 

The A 600 Series current probes are 
specifically designed to support meas- 
urements you make with yoin DMM, 
TekMeter® or oscilloscope. 




A621. 







A622. 



Model Number 


Frequency Range 


Current Range 
RMS to Peak 


Intniment 

Compatibility 


Max. Conductor 


Termination 


A621 


5 Hz to 20 kHz 


100 mA to 2,000 A 


Scop^DMM/TekMeter 


54 mm dia. 


BNC (w/banana adapter) 


A622 


DC to 100 kHz 


50 mA to 100 A 


Scope/DMM/TekMeter 


11.8 mm dia. 


BNC (w/banana adapter) 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



P6117 

lOX, 200 MHz Standard Probe for 
THS 710A/720A/730A. 

P5102 

lOX, High Voltage Probe for THS 700 Series. 

A621 

2000 A AC Current Probe/BNC. 



THS 7BAT 

Ni-Cad Battery Pack. 

THS 7CHG 

Battery Charger. 

THS 7HCA 

Hard Carrying Case. 



Product(s) available through your local Tektronix 
Distributor listed in the back of this catalog. 



ISO 9001 



Tektronix measurement products are manufactured 
in ISO registered facilities. 



A622 

100 A AC/DC Current Probe/BNC. 



108 OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 







WaveStar 

WSTRO • WSTRM 



TM 



Software Family 




Features - Benefits Applications 



Capture Measurement Waveforms 
and Data Easily Without the Need 
for Programming 

Data Log Measurements from a 
Single or Multiple Instruments 

Insert Information in Microsoft 
Office or Windows Applications 

Control Waveform or Meter 
Information Locally or over the 
Network 

Step Away from Your Desk and 
have WaveStar Software 
Automatically Capture Data 
Changes 

For Windows 95/98/NT Systems 

30-Day WSTRO Product Demo 
Available on Web 



Digital Design 

Research and Development 
Manufacturing Test 
Service 
Education 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 



Application Software Designed to 
Capture, Analyze, Document and 
Control Data 

WaveStar Software introduces a family of 
Windows 95/98/NT applications bringing either 
Tektronix TDS/THS/11800/CSA803 oscillo- 
scopes or TX-DMM^” measurement information 
to your PC desktop. 

CAPTURE 

Setup communication to instruments through the 
WaveStar Instrument Manager. The Explorer 
View displays these instruments and reveals their 
corresponding properties. To capture measure- 
ments, select a property, click, drag and drop into 
an active application sheet and begin analysis at 
your PC. 

ANALYZE 

Analyze, aimotate and record information on a 
variety of application sheets. 

Y-T Sheet - Capture and graphically view multi- 
ple waveforms on a graticule, with the same 



scale and position as the oscilloscope. Sheet fea- 
tures cursor measurements, horizontal and verti- 
cal gates, zoom function and annotation. 

X-Y Sheet - Capture and display one or more 
pairs of waveforms plotted against each other in 
an X-Y fashion. Sheet features cursor measure- 
ments and annotation capabilities. 

Stripchart Sheet - Automatically plots multiple 
waveform measurements, such as risetime or 
TX-DMM data, in a classic stripchart fashion. 
Sheet features cursor measurements, alarm con- 
trol, and annotation capabilities. 

Tabular Sheets - Capture, store, display and edit 
either waveform or data log information as a 
table of numbers on corresponding sheets. The 
Scalar Viewer Sheet displays contents of memo- 
ry locations on the TX-DMM Series or measure- 
ments from the oscilloscope. 

Measurement Sheet - Calculate frequency, 
pulse width, rise/fall time, duty cycle, over- 
shoot, peak to peak, amplitude, min, max, 
mean, cycle mean and RMS measurements. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPES 109 






WaveStar™ Software Family 

WSTRO • WSTRM 



Notes Sheet - Prepare simple reports 
right in WaveStar software. Capture and 
save instrument hard copy. Save, edit 
and restore instrument setups. 



DOCUMENT 

Quickly and simply insert information 
into Microsoft Office applications, such 
as Excel, Word or PowerPoint. Transfer 
information into Windows applications, 
such as MathCad, through the Windows 
clipboard. 



CONTROL 

Easily control instrument settings and 
measurements such as autoset and trig- 
gers through the WaveStar 
Explorer View. For convenience, 
WSTRM also includes a unique virtual 
instrument control interface. 



Characteristics 



SOFTWARE COMPATIBILITY 
Instrument Interface Support - GPIB or RS- 
232 interfaces with Full Talk-Listen modes. 
Windows Clipboard - Drag and Drop to 
compatible Microsoft Office Applications or 
copy/paste through Windows clipboard. 
Printer Plotter Support - Uses standard 
Windows printer drivers. 

Waveform Export Format - Microsoft Excel 
6.0 compatible. 

COMPUTER CONFIGURATION 
Required - 

Type: IBM PC-compatible. 

Operating System: Windows 95/98 or 
Windows NT. 

CD-ROM Drive: 4X or better. 

Monitor: Super VGA. 

Recommended 
Processor: Pentium, 100 MHz. 

RAM: 16 M. 

Instrument Interface Card: GPIB: National 
Instruments IEEE-488 Interface Card. 

RS-232: One free RS-232 port. 

Ethernet lOBaseT Interface Card: Inquire about 
Tektronix AD007, GPIB-LAN Adapter. 



Table i. Tektronix Instrument Families Supported 



Product 


Family*’ 


GPIB/RS232 


Restore*^ 


Settings*^ 


Picture** 


WSTRO 


TDS 200-300 


Both 


Yes 


Yes 


Yes 


WSTRO 


TDS 3000 


Both 


Yes 


Yes 


Yes 


WSTRO 


TDS 400-800 


GPIB 


Yes 


Yes 


Yes 


WSTRO 


THS 700 


RS-232 


Yes 


Yes 


Yes 


WSTRO 


CSA803/I1800 


Both 


Yes 


Yes 


Yes 


WSTRM 


TXDMM 


RS-232 


Yes 


Yes 


Yes 


'includes the newest TDS DPO oscilloscopes, as well as legacy series in each family. 

'^Restore waveforms, acquire/restore settings, acquire picture. WaveStar Software acquires wave- 
forms from ALL instruments listed above. 


Table 2 . 


Product 


Features 


Product 




Product 


Features 






WSTRO 




WSTRM 



Data Sheets 

YT, XY, Waveform Tabular, 

and Waveform Measurement Y?5 

Data Logging Stripchart, 

Tabular, a nd Measurement Yes Yes 



Scalar Viewer Tabular 


Yes 


Yes 


Notes 


Yes 


Yes 


Proxies (Drivers) 


All TDS, THS, CSA803, 11800 Series 


Yes 




All TX-DMM 




Yes 


Online Help and Manual 


Yes 


Yes 


Instrument Manager 


Yes 


Yes 


Upgrade From WSTR 3.1 


Yes 




PC Interface Cable 




Yes 


Virtual Meter Interface 




Yes 



110 



OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 





WaveStar™ Software Family 

WSTRO • WSTRM 



Also Available 
WaveStar 3.1 Version 1.3 

ELECTRONIC LAB NOTEBOOK 
SOFTWARE 




Tektronix Digital Storage Oscilloscopes Supported 

WaveStar 3.1 Version 1.3 Software can acquire waveforms from the following scopes; 



Instrument 


CPlB/RS-232 


Restore*' 


Sellings*' 


Picture*' 


11401, 11402/A, 11403/A, 

11801/8, 11802, CSA404, 
CSA803/A, DSA601/A, DSA602/A 


Both 


Yes 


Yes 


No 


2212, 2216, 2430/A, 2432/A, 2440 


GPIB 


Yes 


\es 


No 


2220, 2221A, 2230, 2232 


Both 


Yes 


No 


No 


TDS 200/300 Series 


Both 


Yes 


Yes 


Yes 


TDS 400, TDS 500, TDS 600, 
TDS 700, TDS 800 Series 


GPIB 


Yes 


Yes 


Yes 


THS 700 Series 


RS-232 


Yes 


Yes 


Yes 



Restore waveforms acquire/restore settings, acquire picture. WaveStar Software acquires wave- 
forms from ALL scopes listed above. 




WaveStar (version 1.3). 

APPLICATIONS 

► Capture waveforms and settings 
from digital storage oscilloscopes 

► Annotate, organize and analyze data 

► Perform harmonic analysis up to 
51 harmonics 

► Display table of 22 measurements 

► Store waveforms, pictures, settings 
and notes 

► Read TDS floppies 

► Exchange waveforms and data with 
other windows application software 

► Restore waveforms and settings to 
digital storage oscilloscopes 

► Windows 3.1 application 



PC SOFTWARE CREATES AN 
ELEaRONIC LAB NOTEBOOK 

WaveStar Software version 1.3 is an 
enhanced Windows 3.1 application pro- 
gram from Tektronix that allows the 
user to quickly create an electronic lab 
notebook within their personal comput- 
er to record Tektronix Digital Storage 
Oscilloscope (DSO) measurements. The 
Notebook can capture waveforms 
and/or screen shots, related scope set- 
tings and notes. Further. WaveStar 
Software provides a simple link to 
spreadsheet and documentation soft- 
ware, enabling users to analyze meas- 
urement records or incorporate them 
within other published materials. 



Instrument Interface Support - GPI6 or 
RS-232 interfaces with full Talk-Listen modes. 
Windows Clipboard - Copy/paste through 
Windows Clipboard to other Windows applica- 
tions as bitmaps or metafiles. 

Printer/Plotter Support - Uses standard 
Windows printer drivers supplied by printer 
vendor. 

Waveform Export Format - Microsoft Excel 
4.0 compatible. 

MINIMUM COMPUTER 

CONFIGURATION 

Type - IBM PC-Compatible 386 (486 or 

greater recommended). 

Operating System - Windows 3.1 or later in 
386 Enhanced mode. 

RAM - 4 MB or greater. 

Hard Disk - 5 MB free space. 

Floppy Disk - One 3.5 in. high-density disk 
drive. 

Monitor - VGA or better. 

Interface Card (DSO must have appropri- 
ate interface installed) - 

GPIB: National Instruments IEEE-488 
Interface Card. 

RS-232: One free RS-232 port. 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



WSTRO 

WaveStar Software for Oscilloscopes, Windows 
95/98/NT Version. 

Includes; CD ROM, Manual (071-0220-00). 

WSTRM 

WaveStar Software for Meters, Windows 
95/98/NT Version. 

Includes: CD ROM, PC Interface Cable with 9- to 25- 
Pin adapter (118-9828-00), Boot Insert (377-0625- 
00), Manual (071-0220-00). 



WSTROU 

WaveStar 3.1 (WSTR31) Upgrade to WaveStar for 
Oscilloscopes, Win 95/98/NT Version. 

Includes; 1 CD-ROM Disk, Manual (071-0220-00). 

WSTR31 

WaveStar Software version 1.3 for Windows 3.1. 
Includes: 3.5 in. Disk, Manual (070-9785-01). 



For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 



www.tektronix.com/Measurement/scopes/ 



OSCILLOSCOPES ill 






Sampling Oscilloscopes 



Contents 

Software (WaveStar) 109 

11801C 113 

Sampling Heads 116 

CSA 803C 290 

Probes 495 

SMD Adapters 535 

Probe and Instrument 

Accessories 540 

Instrumentation Carts 582 



11800 Series 

The Tektronix 11800 Series is a powerful set of analysis tools that alter your funda- 
mental expectations of an oscilloscope. Most revolutionary is the simplification and 
automation of the entire measurement and analysis process. Accuracy, sensitivity, 
bandwidth, offset and overdrive recovery are provided by a well-planned instru- 
ment family having plug-in versatility and performance. Multiprocessor architec- 
ture allows for simultaneous display of up to eight waveforms and up to six dynam- 
ic, “live” measurement readouts. The automation needs of scientific and production 
environments are easily met by integrating these instruments into a measurement 
system through RS-232-C or GPIB interfaces. 



CSA Series 

The Communications Signal Analyzer (CSA) offers signal analysis and the powerful 
measurement capabilities required to analyze high-speed digital communication 
signals. Features of the CSA 803C include histograms, mask testing and a color- 
graded display, allowing you to perform accurate measurements such as jitter, noise 
and phase. 



112 



DIGITIZING OSCILLOSCOPES 



www.tektronix.com/Measureinent/scopes/ 





Features - Benefits Applications 



DC To 50 GHz Bandwidth Semiconductor Test 

7 Ps Rise Time TDR Characterization 

Eight Channels, Expandable to 136 High Speed Digital 
(with SM-1 1 multi-channel units) Qgta Communication 
High Resolution and Measurement 
Repeatability 

10 Femtosecond Sampling Interval 
(0.01 ps) 

Modular Architecture 

Dual Timebase Allows Multiple 
Windows 



FFT 

Predefined Telecom Masks 
True Dual-Step Differential TDR 

Fully Automatic Jitter and Noise 
Measurements 

Automatic Statistical 
Measurements, Histograms and 
Mask Testing 

Automatic Pulse Measurements 
with Statistics 

Comprehensive Waveform 
Processing 

Complete Programmability for ATE 
Applications 

Color Display with Color Grading 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 

C€ 

1^0 9001 



The 11801 C Digital Sampling 
Oscilloscope 

The 11801C Digital Sampling Oscilloscope 
offers the widest range of on-hoard measure- 
ment and waveform processing capabilities of 
any multi-Gigahertz scope. With excellent meas- 



urement repeatability, exceptional vertical reso- 
lution and fast display update rate, the II 8 OIC 
is a powerful measurement tool for semiconduc- 
tor testing, TDR characterization of circuit 
boards. 1C packages and cables, and high speed 
digital data communications. 



Tektronix measurement 
products are manufactured in 
ISO registered facilities. 



www.tektronix.com/Measurement/scopes/ 



DIGITIZING OSCILLOSCOPES 113 








Digital Sampling Oscilloscope 

11801C 



MODULARITY MEETS YOUR NEEDS 
NOW AND IN THE FUTURE 

The modular microprocessor-based 
architecture of the 11801C not only 
allows you to select tlie right configura- 
tion for your application, but also 
allows expandability to meet your 
future measurement needs. The 11801C 
accepts up to 4 dual-channel sampling 
heads and can be expanded through the 
SM-11 Multi-Channel Units to 136 
channels. There are currently nine sam- 
pling heads to choose from: 

► SD-14 3 GHz high impedance 
(100 kn/0.475 pF) dual-channel 
probe sampler 

► SD-20 20 GHz single-channel loop- 
through head 

► SD-22 12.5 GHz dual-channel low 
noise head 

► SD-24 20 GHz dual-channel TDK/ 
sampling head 

► SD-26 20 GHz dual-channel 
sampling head 

► SD-32 50 GHz, single-channel 
sampling head 

► SD-42 6.4 GHz O/E converter (55 ps 
optical pulse response FWHM) 

► SD-44 15 GHz O/E converter 

► SD-51 20 GHz trigger head 



114 DIGITIZING OSCILLOSC 



Characteristics 



VERTICAL SYSTEMS 

Rise Time/Bandwidth - Determined by the 

sampling head used.*’ 

Vertical Resolution - 8 bits full screen (78 
pV LSB at 2 mV/div deflection factor). 
Amplifier Gain Accuracy - ±1% of all set- 
tings. 

Deflection Factors - 2 to 255 mV/div in 
1 mV/div increments. 

Offset Range - ±2 V. 

HORIZONTAL SYSTEM 

Main and Window Time Base - 1 ps/div to 

5 ms/div, settable in 1-2-5 sequence or in 1 ps 

increments. 

Time Interval Accuracy - 8 ps + 0.01% x 
(interval) + 0.001% x (position), guaranteed; 

4 ps + 0.004% X (interval) + 0.0004% x (posi- 
tion), typical, where interval >1 ns; 

2.5 ps + 0.0004% X (position), typical, where 
interval = 100 ps; 

1 ps + 0.0004% X (position), typical, where 
intervals <10 ps. 

Notes: 1) For intervals <100 ps, the above 
holds for time/div <20 ps/div. 

2) For other intervals not listed above, linearity 
interpolate the cardinal points. 

Record Length - 512, 1024, 2048, 4096 and 
5120 samples. 

Windows - Any number of window records 
may be placed on any number of main records, 
up to a maximum of 8 displayed traces. All win- 
dow records have the same duration, but may 
be independently positioned on any main 
record. Windows may be set to automatically 
track a moving edge on the main record. 
Maximum Sampling Rate - 200 ks/s. 

TRIGGER SYSTEM*^ 

Trigger Bandwidth - Direct 4 GHz typical. 
Prescaled 12.5 GHz typical. 

Trigger Sensitivity - Direct DC to 4 GHz: 

50 mV typical. 

Prescaled 2 to 10 GHz: 500 mV, 

10 to 12.5 GHz: 800 mV typical. 



Delay Jitter - 1.1 ps +4 ppm of a position 
typical. 2.0 ps +5 ppm of position 
maximum (rms). 

Metastability: Raw <0.005 ppm at 2.488 GHz 
with 200mV Input trigger voltage, typical. 
Enhanced is theoretically zero. 

Internal Clock - 100 kHz (drives TDR, 

Internal Clock Output and Calibrator). 

Trigger Level Range - ±1.0 V (±10 V with 
lOX trigger attenuator activated). 

Trigger Input Range - ±1.5 V (±1.5 V, 5 V 
rms maximum with lOX). 

Trigger Holdoff - 5 ps to 2.5 s. 

MEASUREMENT SYSTEM 
Waveform Processing Functions - Add, 
subtract, multiply, divide, absolute, average, 
differentiate, envelope, exponent, integrate, 
natural log, log, signum, square root, 
smoothing and filter. 

Measurement Set - Max, min, mid, p-p, 
mean, rms, amplitude, extinction ratio, over- 
shoot, undershoot, noise*^ rise, fall, spectral 
magnitude, spectral frequency, THD, SNR, fre- 
quency, period, prop delay, cross, width, 
phase, duty cycle, jitter*^ area +, area -, and 
energy. Measurements are constantly updated; 
mean and standard deviation available on all 
measurements. 

Measurement Parameters - (Proximal, 
mesial, distal and start/stop levels): May be set 
to absolute levels. 

Cursors - Paired or split dots, vertical bars, 
and horizontal bars. 

TDR SYSTEM (SD-24 ONLY) 

Combined TDR/Acquisition Reflected 
Risetime - 35 ps or less. 

TDR Step Amplitude - Adjustable to ±250 mV 
(polarity of either step may be inverted). 

Time Coincidence Between TDR Steps - 
Adjustable to less than 1 ps. 

Source Resistance - 50 ±0.5 Q. 

Typical Aberrations (at ±250 mV 
Amplitude) - 

10 ns to 20 ps before step: ±3% or less; 
less than 300 ps after step: +10%, -5% or less; 
300 ps to 5 ns after step: ±3% or less; else- 
where: ±1% or less. 



P E S 



www.tektronix.com/Measurement/scopes/ 





Digital Sampling Oscilloscope 

11801C 



CRT AND DISPLAY FEATURES 

CRT - 9 in. diagonal, magnetic deflection, ver- 
tical raster scan orientation. Color. 

Colors - Eight-color default color set included; 
or, colors are user-selectable from palette of 
262,144 colors. 

Video Resolution - 552 horizontal by 704 
vertical displayed pixels. 

Vertical system specifications of 11801C with 
SD-14 non-applicable. See 11800 Series 
Sampling Head specifications. 

11801C has external trigger only; requires 
23 ns pretrigger or DL-1 1 Delay Lines to view 
trigger point (45.5 ns with Option IM). 
Available only in statistical measurement 
mode. 



POWER REQUIREMENTS 

Line- Voltage Ranges - 90 to 132 V rms, 180 

to 250 V rms. 

Line Frequency - 48 to 440 Hz. 

Maximum Power Consumption - 214 W. 

ENVIRONMENTAL AND SAFETY 
Temperature - Operating: 0®C to +50®C; 
nonoperating: -40°C to +75°C. 

Humidity - Operating and nonoperating: up 
to 95% relative humidity, up to 50°C. Per Mil-T- 
28800E, Type III, Class 5. 

Altitude, Vibration, Shock nonoperating. 
Bench Handling - Meets MIL-T-28800E, 

Type III, Class 5. 

Electromagnetic Compatibility (with sam- 
piing heads or optional blank panels 
installed in all sampling head compart- 
ments) - Meets the requirements of: MIL- 
STD-461B; FCC Part 15, sub-part J, Class A; 

VDE 0871/6.78 Class B. 

Safety - Listed UL 1244, CSA Bulletin 556B 
September 1973. 



Physical Characteristics 

Cabinet Rackmount 



Dimensions 


mm 


in. 


mm 


in. 


11801C 

Width 


448 


17.6 


483 


19.0 


Height 


238 


9.4 


222 


8.8 


Depth 


599 


23.6 


550 


21.6 


SM-11 

Width 


448 


17.6 


483 


19.0 


Height 


238 


9.4 


222 


8.8 


Depth 


558 


22.0 


550 


21.6 


Weights 


M 


lb. 


H 


lb. 


11801C 

Net 


22.3 


49.0 


23.2 


51.0 


Shipping 


25.9 


57.0 


26.8 


59.0 


SM-11 

Net 


20.0 


44.0 


20.9 


46.0 


Shipping 


23.6 


52.0 


24.5 


54.0 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 



11801C 

Digital Sampling Oscilloscope. 

Includes: User Manual (070-9971-00); 

Programmer Manual (070-9970-00); 

Service Manual (070-9972-00); 

12-in. SMA-SMA cable, 

2 ea. 8-1/2-in. SMA-SMA cable, 

1 wrist strap. 

Opt. IM - Multi-Channel Conversion: Modifies 
1 1801 C to permit operation with up to four SM-11 
Multi-Channel Units. 

Opt. 1R - Rackmount. 

Includes: Hardware, tooling and instructions for 
converting bench model to rackmount configuration. 
Available with 11801C. 

DL-11 

Delay Line. 

Includes: Delay Line Instruction Sheet - 
Order 070-7051-01. 



INTERNATIONAL POWER PLUGS 
Opt. A1-A5 - Available. 

See page 619 for description. 

ADDITIONAL ACCESSORIES 
Calibration Step Generator - USA (067- 1338- 
00); Europe (067-1338-01); UK (067-1338-02); 
Australia (067-1338-03); Switzerland (067-1338-05); 
Japan (067-1338-06). 

Sampling Head Extender Cable, l meter - 

Order 012-1220-00. 

Sampling Head Extender Cable, 2 meter - 

Order 012-1221-00. 

DL-11 Service Manual - Order 070-7050-01. 
Blank Panel for Empty Sampling Head 
Compartments - Order 200-3395-00. 

ECL Terminator - Order 015-0558-00. 

SMA Accessory Kit - Order 020-1693-00. 

RECOMMENDED PROBES 
P6150 - 9 GHz Passive Probe. 

P6249/1103 - 4 GHz Active FET Probe and Power 
Source. 



C€ 

jg ISO 9001 

Tektronix measurement products are manufactured 
in ISO registered facilities. 



DIGITIZING 



OSCILLOSCOPES 



www.tektronix.com/Measurement/scopes/ 



115 





SD -14 • 
ORR24 



SD-20 
• SD-51 



SD-12I -26 



SD-32 • SD-42/-44 • 




For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1 - 503 - 627 - 1916 , 
inside the U.S. call: 
1 - 800 - 426 - 2200 . 

CC 



j g ISO 900 1 

Tektronix measurement 
products are manufactured in 
ISO registered facilities. 



Features - Benefits 



ECU CMOS and ACL GaAs Device 
Characterization (SD-14) 

Special TDR Communications 
(SD-20) 

Digital Data Communications 
(SD-22) 

TDR/TDT Crosstalk (SD-24) 

Device Characterization (SD-26) 

High Bandwidth Communication & 
Microwave (SD-32) 

Optical-to-electrical (SD-42/SD-44) 

SONET/SDH Compliance Testing 
(ORR-24) 

Triggering Countdown (SD-51) 

SD-26 

20 GHz Bandwidth 
Dual-channel 

SD-32 

50 GHz Bandwidth 
Single-channel 
2.4 mm Connector 

SD-42*^ 

DC to 6.4 GHz Optical Bandwidth 
1000-1700 nm Wavelength Range 
SD-44*’ 

DC to 15 GHz 

1 100 - 1650nm Wavelength range 

ORR24*i 

DC to 2.0 GHz 

1310-1500 nm Wavelength Range 

SD-51 

1 to 20 GHz Bandwidth 
Less Than 6 ps rms Jitter 



SD-14 

100 kO, 0.5 pF Typical 
7 V p-p Dynamic Range 
3 GHz Bandwidth 

SD-20 

Non-terminated 

SD-22 

12.5 GHz Bandwidth 

Low-noise 

Dual-channel 

SD-24 

20 GHz Bandwidth 
35 ps Reflected Rise Time 



116 DIGITIZING OSCILLOSCOPES 



www.tektronix.com/Measurefflent/scopes/ 






Sampling Heads 

SD-14 • SD-20 • SD-22/-24/-26 • SD-32 • SD-42/-44 • ORR24 • SD-51 



SD-14 High Impedance Probe 
Sampler 

The SD-14 is a dual-channel, 3 GHz 
probe sampler designed for high-imped- 
ance signal acquisition where a 50 Q 
acquisition system is not the optimal 
solution. The SD-14 is ideal for high- 
speed device characterization such as 
ECL, CMOS, ACL and GaAs testing. 

The 100 kn input impedance and 0.5 
pF capacitance results in very low load- 
ing of the device under test. The 7 V 
dynamic range and ±3.5 V offset range, 
makes the SD-14 suitable for testing all 
digital logic families as well as most 
analog circuits. 

The SD-14 consists of two samplers, 
each attached at the end of a 1.0 meter 
cable for easy circuit probing. The mod- 
ular architecture of the CSA 
803C/11801C enables the use of extend- 
ed samplers, bringing a new level of 
performance to sampling scopes. In 
conjunction with the 11801C and SM- 
11 multi-channel unit, it is possible to 
configure up to 136 channels of high- 
impedance, high-bandwidth acquisition 
with measurement accuracy approach- 
ing 140 ps. 

SD-14 Option 01 adds a longer probe tip, 
two probe-to-ECB (etched circuit board) 
adapters, and two probe-to-SMB adapters. 
These ease probing of plated holes (as 
found in Outboards for IC testers) and 
semi -permanent connections. 

SD-20 Loopthrough 
Sampling Head 

The SD-20 is a single-channel, 20 GHz 
loopthrough sampling head designed 



for low-loss testing in applications 
such as microwave systems research 
and development, digital device char- 
acterization and high-speed digital 
communications circuit design. It pro- 
vides an acquisition rise time of 
17.5 ps with typically 750 pV rms of 
noise (350 pV with smoothing) to 
ensure clean, undistorted signals. 

The SD-20 is nonterminated and keeps 
losses to a minimum by routing the sig- 
nal of interest directly through the sam- 
pling head without the need of a power 
divider. The SD-20 can also be used for 
customized TDR measurements of 
transmission lines and controlled 
impedance devices. An external signal 
generator may be used, instead of the 
SD-24 step generator, to tailor the TDR 
stimulus to fit a particular situation. For 
instance, slower slew rates or higher 
amplitude may be utilized, or you may 
perform half-sine or impulse testing. 

In digital communications, the SD-20 
is useful for viewing and triggering on 
the clock signal without the use of a 
power divider. 

SD-22 Low-noise Sampling 
Head 

The SD-22 is a dual-channel, 12.5 GHz 
sampling head specifically designed for 
low-noise measurement in digital com- 
munications and device characteriza- 
tion applications. It provides an acqui- 
sition rise time of 28 ps, and typically 
450 pV rms of displayed noise. With 
smoothing, noise levels are 180 pV rms. 

In order to precisely capture and dis- 
play the switching characteristics of 



high-speed communications circuits, to 
make accurate statistical measurements 
of signal noise and signal timing jitter, 
or to obtain stable timing measurements 
of fast digital ICs, the noise floor of the 
test equipment must be kept to a mini- 
mum. The SD-22 is the ideal instru- 
ment for these low-noise applications. 

SD -24 TDR/Sampling Head 

The SD-24 is a dual-channel 
TDR/Sampling Head. This sampling head 
has a rise time of 17.5 ps or less, with a 
typical 20 GHz equivalent bandwidth. 

Each channel of the SD-24 is also capa- 
ble of generating a fast rising step for 
use in Time Domain Reflectometry 
(TDR). In TDR mode, the acquisition 
portion of the sampling head monitors 
the incident step and any reflected 
energy. The reflected rise time of the 
TDR step is 35 ps or less. The polarity 
of each channel’s TDR step can be 
selected independently of the other 
channel. This allows for differential or 
common-mode testing of two coupled 
lines, in addition to the independent 
testing of isolated lines. The SD-24 can 
be used to characterize crosstalk by 
using the TDR step to drive one line 
while monitoring a second with the 
other channel. 

The “filter” function on the CSA 
803C/11801C can be used with TDR or 
crosstalk measurements to characterize 
a system at a slower rise time. 

SD -26 Sampling Head 

The SD-26 is a dual-channel, 20 GHz 
equivalent bandwidth sampling head. 
This sampling head has the same acqui- 



Sampling 


Head Characteristics 

Channels Bandwidth 


Rise Time 


Impedance 


Noise 


Applications (IVpical) 


SD-14 


2 


3 GHz (typical) 


140 ps 


100 kD/0.5 pF 
0.55 pF Opt 01 


2 mV 


ECL, CMOS, ACL GaAs 
Dev. Characterization 


SD-20 


1 


20 GHz 


17.5 ps 


50 D unterm. 


750 (IV 


Special TDR, Communications 


SD-22 


2 


12.5 GHz 


28 ps 


50 D 


450 mV 


Communications 


SD-24 


2 


20 GHz 


17.5 ps 


50 D 


750 |lV 


TDR/TDT Crosstalk 


SD-26 


2 


20 GHz 


17.5 ps 


50 D 


750 mV 


Device Characterization 


SD-32 


1 


50 GHz 


7.0 ps 


50 D 


1.8 mV 


High Bandwidth 
Communications & Microwave 


SD-42 


1 


6.4 GHz 








Optical-to-electrical 


SD-44 


1 


15 GHz 








Optical-to-electrical 


ORR-24 


1 


2.0 GHz 


205 ps 


50 D 




Optical Reference Receivers 
(SONET/SDH) 


SD-51 




20 GHz 




50 Q 




Trigger Countdown Head 



www.tektronix.com/Measurement/scopes/ 



DIGITIZING OSCILLOSCOPES 117 



Sampling Heads 

SD-14 • SD-20 • SD-22/-24/-26 • SD-32 • SD-42/-44 • 0RR24 • SD-51 



sition capability as the SD-24 
TDR/Sampling Head but does not 
include the TDR step generators. 

SD -32 Sampling Head 

The SD-32 is a single-channel, 50 GHz 
bandwidth sampling head. The SD-32 
performance is available for any new or 
existing CSA 803A/11801B mainframe. 
The SD-32 has measured bandwidth of 
greater than 50 GHz and calculated rise 
time less than 7.0 ps. The front-panel 
connector is female 2.4 nun, and an 
adapter is provided (011-0157-00; 2.4 
mm male to 2.92 mm female) in order 
to maintain compatibility with SMA 
connector systems. 

SD-42 Optical-to-electrical 
Converter*’ 

The SD-42 Optical-to-electrical 
Gonverter head can be used to analyze 
optical signals in the 1000 nm to 
1700 nm wavelength range. The pulse 
response of the measurement system is 
less than 55 ps FWHM (Full-width, 
Half-maximum), which is equivalent to 
a calculated bandwidth of DC to 6.4 
GHz. The electrical output on the front 
panel is coupled to the adjacent sam- 
pling head via the semi-rigid coaxial 
link provided. 

The SD-42 is also equipped with an 
optical power meter for average power 
monitoring through a pair of voltage 
outputs on the front panel. Power from 
5 nW to 5 mW can be measured. 

SD-44 Optical-to-electrical 
Converter*’ 

The SD-44 is an optical-to-electrical 
(0/E) converter for use with the 
Tektronix CSA 803 and 11800 Series 
sampling oscilloscopes equipped 
with an SD-2x or SD-3x Electrical 
Sampling Head. The SD-44 Optical-to- 
electrical Converter can be plugged 
directly into a 11800 sampling slot, 
CSA 803 power slot, or attached via 
a sampling head extender cable for 
remote use. The head extenders 
come in either 1 meter (012-1220-00) 
or 2 meter (012-1221-00) options. 

Optical signal input on the SD-44 is a 
standard FC/PC fiber optic connector. 
Other connector types can be accommo- 
dated by using hybrid fiber optic 






jumper cables (SA/SD-42) or an assort- 
ment of hybrid mating adapters (SD-44). 

ORR-24 Optical Reference 
Receiver*’ 

The Synchronous Data Hierarchy (SDH) 
and the Synchronous Optical NETwork 
(SONET) standards are the cornerstones 
of today’s high-speed digital telecom- 
munications systems. The Tektronix 
ORR24 optical reference receiver pro- 
vides an important interface for compli- 
ance testing of SDH/SONET optical 
transmission products or components. 

The amplified design of the ORR24 con- 
verts the incoming optical light into a 
high gain, low noise electrical signal. 
This allows easy testing of optical 
designs as well as repeatable measure- 
ments. The ORR24 is DC coupled 
which is required for accurate extinc- 
tion ratio measurements. 

SD-51 Trigger Head 

The SD-51 Trigger-countdown Head pro- 
vides stable displays of signals from 1 to 
20 GHz with less than 6 ps rms jitter. 

The SD-51 is a free-rimning tunnel 
diode oscillator with a front-panel con- 
trol to synchronize the oscillator to a 
subharmonic of the input signal and the 
output oscillator to a subharmonic of 
the input signal. The output from the 
SD-51 is coupled to the CSA 
803C/11801C Series trigger input con- 
nector. The output signal is a direct 
countdown of the input (and the input 
connector) and permits triggering by the 
sampling time base unit. 

For more information on this product, see 
Telecommunications products section of 
this catalog. 



Characteristics 



Ao|uisition System - SD-14, SD-22, SD-24, SD- 
26; dual channel; SD-20, SD-32: single channel. 
Rise rime - SD-14: 140 ps; SD-20, SD-24, SD- 
26: 17.5 ps; SD-22: 28 ps, all from 10% to 90%. 
Bandwidth - 3 GHz (typical) for the SD-14; 

20 GHz for the SD-20, SD-24, and SD-26; 12.5 
GHz for the SD-22; 50 GHz for the SD-32. 
Dynamic Range - 1 V p-p within a ±1.6 V 
range for the SD-20, SD-22, SD-24, SD-32; 7 V 
p-p within a ±3.5 V offset range for the SD-14. 
Dot Transient Response - Accuracy after cal- 
ibration at operating temperature is ±5% for 



signals up to 0.5 V p-p. Adjustable to unity for 
signals up to 1.0 V p-p. 

Input Impedance - SD-22, SD-24, SD-26, SD- 
32: 50 n ±0.5 n. SD-14 is 100 ki2 and 0.5 pF 
(0.55 pF for Option 01). SD-20 is not terminat- 
ed and not rated. 



Displayed Noise - 

Maximum Typical 



With unity dot response: 


SD-20, SD-24, Sp-26 


1.2 mV 


750|iV 


SD-22 


800 pV 


450 mV 


SD-14 


8 mV 


7 mV 


SD-32 


2.3 mV 


1.8 mV 


With smoothine: 


SD-20, SD-24, SD-26 


550 gV 


350 |jV 


SD-22 


400 mV 


180 mV 


SD-32 


1 mV 


700 mV 



Aberrations (typical) (SD-20, SD-22, SD- 
24, SD-26 only) - The following are acquisi- 
tion aberrations. 10 ns to 20 ps before step: 
±3% or less. <300 ps after step: +10%, -5% or 
less. 300 ps to 5 ns after step: ±3% or less. 

300 ps to 5 ns after step: ±4 or less (SD-20 
only). 5 ns to 100 ns after step: ±1% or less. 
Elsewhere: ±0.5% or less. 

Aberrations (typical) (SD-14 only) - 
<1.5 ns after step: +12%, -25%, 1.5 ns to 4 ns 
after step: +1%, -3%, 4 ns to 30 ns after step: 
±2%. Elsewhere: ±1%. 

Maximum Input Voltage - ±3 V. SD-14: 

±15 V; SD-32: ±2V. 

Isolation Between Channels - 1% p-p volt- 
age transmission from the channel driven by 
the 067-1338-00, to the quiescent channel (see 
page 121 in this catalog). 

Time Coincidence Between Channels - 
10 ps accuracy; <0.2 ps/®C stability. 

TDR SYSTEM (SD-24 ONLY) 

Displayed Rise Time. 

Incident - 28 ps typical, 10% to 90%, at 
+250 mV or -250 mV output elsewhere ±1%. 
Reflected - 35 ps or less, 10% to 90%, at 
+250 mV or -250 mV output. 

TDR Step Amplitude - Adjustable to ±250 mV 
(polarity of either step may be Inverted). 

Time Coincidence Between TDR steps - 

Adjustable to less than 1 ps. 

Source Resistance - 50 Q ±0.5 Q. 
Aberrations (at ±250 mV amplitude) - The 
following are TDR aberrations. 10 ns to 20 ps 
before step: ±3% or less. <300 ps after step: 
+10%, -5% or less. 300 ps to 5 ns after step: 
±3% or less. Elsewhere: ±1% or less. 



118 DIGITIZING OSCILLOSCOPES 



www.tektronix.coni/Measurefflent/scopes/ 





Sampling Heads 

SD-14 • SD-20 • SD-22/-24/-26 • SD-32 • SD-42/-44 • 0RR24 • SD-51 



ENVIRONMENTAL AND SAFETY 
CHARACTERISTICS 

(11801C, CSA 803C, SD-Series Heads) 
Temperature - Operating: 0°C to +50°C; 
nonoperating: -40®C to +75°C. 

Altitude, Vibration, Shock, Bench 
Handiing - Operating and nonoperating: 
meets MIL-T-28800C, Type III, Class 5. 
Electromagnetic Compatibility (not SD-14) - 
Meets the following requirements of MIL-STD- 
461 C: CE-03 R 4 Curve 1, CS-01 R 7, CS-02 R 4, 



CS-06 R 5, RE-02 R 7, RS-01 R 4, RS-02 R 5, 
RS-03 R 7 (limited to 1 GHz). Meets FCC Part 15, 
subpart J, Class A. For Germany: Meets VDE 
0871/6.78 Class B. (Not all for SD-14.) 

Humidity - To 95% RH at up to 50®C. 

CHARAaERISTICS (SD-51) 

Input Signal - Frequency range is 1 to 20 
GHz. Stable synchronization on signals of at 
least 100 mV p-p, as measured separately Into 
50 n, 5 V p-p max. 



Input Characteristics - 50 L2 SMA (3 mm) 

connector. Open termination paralleled by 1 pF. 
Trigger Output - Approximately 200 mV into 
50 Q. Jitter Is 6 ps rms or less with signals 
from 5 to 20 GHz; 7 ps rms or less with signals 
from 1 to 5 GHz. Kickout at signal input is 
180 mV peak; kickout occurs between succes- 
sive samples. 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



SD-14 

High Impedance Probe Sampler. 

Includes: Installation/User Manual (070-8286-01); 
Service Manual (070-8285-01); 4-post ECB Mount 
Ground Socket; Edge Tab Ground Socket; 10 ea. 
Wire-form Ground, .050 Spacing; 10 ea. Wire-form 
Ground, .040 Spacing; Plastic Accessories Case. 

Opt. 01 - Longer Probe Tip, Probe to ECB Adapters, 
Probe to SMB Adapters. 

SD-20 

Loopthrough Sampling Head. 

Includes: Installation/User Reference (070-7531-01), 
Service Reference (070-7528-01), Precision 3.5-mm 
Termination (011-0155-00), 2 SMA Short-circuit 
Terminations (015-1020-00). 

SD-22 

Low-noise Sampling Head. 

Includes: Installation/User Reference (070-7226-02), 
Service Reference (070-7227-02), 2 SMA Short-circuit 
Terminations (015-1020-00). 

SD-24 

Dual TDR/Sampling Head. 

Includes: Installation/User Reference (070-7052-01 ), 
Service Reference (070-7053-01), SMA Short-circuit 
Terminations (015-1020-00). 

SD-26 

Dual Sampling Head. 

Includes: Installation/User Reference (070-7226-02), 
Service Reference (070-7227-02), 2 SMA Short-circuit 
Terminations (015-1020-00). 

SD-32 

Sampling Head. 

Includes: Installation/User Reference (070-8268-01); 
Service Reference (070-8269-01); 1 SMA Short-circuit 
Termination (015-1020-00); 2.4 mm Male to 2.92 mm 
Female Adapter (011-0157-00). 

SD-42 

Optical-to-electrical Converter. 

See the Telecommunication Instruments section for 
complete information. 

SD-44 

Optical-to-electrical Converter. 

Includes: Hard Case, User Manual (English), 
Assorted Fiber Optic Hybrid Connectors (FC/FC, 
FC/ST, FC/SC), FC/FC Single-mode Fiber Jumper, 
Rigid 50 Q U-Cable, Certificate of Traceable 
Calibration. 



SD-44 External Power Supply with SD-4x 
Adapter Gible - Order 016-1609-00. Includes: lEC 
Compatible Power Supply, SD-44 Adapter Cable, U.S. 
Power Cord, Instruction Sheet. 

INTERNATIONAL POWER PLUGS 

Order European: 161-0066-09. 

Order UK: 161-0066-10. 

Order Australia: 161-0066-11. 

Order Switzerland: 161-0154-00. 

See page 619 for description. 

DIN/FC Fiber Optic Hybrid Connector - Order 
119-5118-00. 

10 kHz to 21 GHz DC Block - 

"N" Type: Order 015-0509-00. 

"K" to "N" Type Adapter: Order 015-0369-00. 

1101A 

Tektronix Power Supply. 

Includes: Hard Case, User Manual (English), 
Assorted Fiber Optic Hybrid Connectors (FC/FC, 
FC/ST, FC/SC), FQFC Single-mode Tiber Jumper, 

50 Q SMA Cable, Frequenq Response Graph, 
Certificate of Traceable Calibration. 

SD-51 

Trigger Head. 

Includes: Installation/User Manual (070-7338-01), 
Service Reference (070-7339-01), 12 in. SMA Male-to- 
male (174-1364-00). 

MEASUREMENT SERVICE OPTIONS 
SD-14 

Opt. R3 - Repair warranty extended to cover three 
years. 

SD-20/-22/-24/-26/-32/-42/-44 
Opt. C3 - Three years of Calibration Services. 

Opt. D3 - Test Data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover three 
years. 

SD-51 

Opt. C3 - Three years of Calibration Services. 

Opt. R3 - Repair warranty extended to cover three 
years. 

ORR24 - Optical Reference Receiver. 



RECOMMENDED ACCESSORIES 

Also see page 495. 

PROBES 

P6150 - 50 a. Divider Probe, 2 tips: IX, lOX. IX: 3 
GHz; lOX: 9 GHz. 

P6158 - 20X, 3 GHz/KQ. 

See page 520. Requires SMA Male-to-BNC female 
adapter when attached to SMA-type inputs. 

Order 015-0554-00. 

ADDITIONAL ACCESSORIES 

Also see page 495. 

2X Attenuator - SMA Male-to-female. 

Order 015-1001-00. 

5X Attenuator - SMA Male-to-female. 

Order 015-1002-00. 

75 Q to 50 Q Min. Loss Attenuator - 

BNC Order 011-0112-00. 

Blank Sampling Head - Order 200-3395-00. 

SMA Accessory Kit - 2 ea. 2X and 5X Attenuators; 

2 ea. SMA Terminations, Male Short Circuit, Female 
Short Circuit, Male 50 Q , Female 50 ^1 , 2 ea. 50 Q 
Signal Cables (2 ns), 2 ea. 500 ps Semi-rigid Cable, 2 
ea. Male-to-male Adapters, 2 ea. SMA Male-to-BNC 
Female, 2 ea. Female-to-female, 1 ea. 50 Q Power 
Divider, 1 ea. Combination Wrench (.312, 6 point). 
Order 020-1693-00. 

ECL Terminator - Provides the bias and termina- 
tion for ECL device outputs. At 10 GHz bandwidth 
and 1% precision attenuation, accurate AC and DC 
measurements are ensured. Attenuation: lOX ±1.0% 
@ DC, 20 dB ±3 dB, DC to 10 GHz. Aberrations: ±3% 
max with 100 ps Rise Time. Order 015-0558-00. 

DC Block (Coupling Capacitor) - BNC. 

Order 015-1013-00. 

Slip-on Connector - Order 015-0553-00. 
Connector Savers - (SMA) Order 015-0549-00. 

CABLES AND EXTENDERS 
Sampling Head Extender Cables - 

(1 m) Order 012-1220-00. 

(2 m) Order 012-1221-00. 

Acquisition Extender - Order 067-1324-00. 
Acquisition System Extender - Order 067-1323-00. 
Card Cage Extender - Order 067-1267-00. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 



DIGITIZING OSCILLOSCOPES 119 



www.tektronix.com/Measurement/scopes/ 




Delay Line/Stat 
Unit/Calibratio 



DL-11 • SlU 800 



1C 

N 



Isolation 

Step Generator 




Features - Benefits Applications 



DL-11 

47.5 ns Compensated Dual Delay 
Line 

5 GHz Bandwidth 
CALIBRATION STEP GENERATOR 
250 mV 

Verifies Specifications of SD-14, 
SD-20, SD-22, SD-24, SD-26 
Sampling Heads 

SlU 800 

<40 PS Reflected Rise Time When 
Used with SD-24 

<80 mp Reflection Coefficient 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1 - 503 - 627 - 1916 , 
Inside the U.S. call: 
1 - 800 - 426 - 2200 . 

NOT AVAILABLE IN EUROPE. 



f LS_0 M1 



Tektronix measurement 
products are manufactured in 
ISO registered facilities. 



DL-11 Delay Line 

The DL-11 Delay Line provides approximately 

47.5 ns of delay from the signal input to the sig- 
nal output. The DL-11 contains two delay lines 
that, when connected, allow you to view the 
triggering event through the 11801C or CSA 
803C. The DL-11 has approximately 5 GHz band- 
width and attenuates the signal by 50%. 

A delay line can reduce horizontal jitter and pro- 
vide more accurate measurements, because it 
lets you take measurements on the first rising 
edge of the triggering event. 

The DL-11 Delay Line contains two delay lines 
each with 47.5 ns delay. The DL-11 is used for 
showing the triggering event of a signal dis- 
played on an 11801C or a CSA 803C. 

Physical Characteristics 



Dimensions mm in. 



Width 


159 


6.3 


Height 


119 


4.7 


Depth 


356 


14 


WeigM 


H 


lbs. 


Net 


2.2 


10 


Shipping 


3.08 


14 



Calibration Step Generator 

The Calibration Step Generator is a very fast rise 
time, 250 mV step generator that verifies specifi- 
cations of the SD-14, SD-20, SD-22, SD-24, and 
SD-26 sampling heads. It is supplied with a cer- 
tificate and test report, stating the rise time of the 
step based on a measurement-controlled, internal 
Tektronix acquisition standard, to a tolerance of 

2.5 ps typically. This reported rise time will not 
exceed 19.5 ps. The output connector is a preci- 
sion 3.5 mm male that allows direct interface to 
the SD-Series head. The step generator is triggered 
directly from the Internal Clock Output on a CSA 
803C/118()1C Series mainframe. 

SlU 8oo Static Isolation Unit 

The SIU 800 protects the sampling bridge from 
damage due to static discharge from circuit 
boards and cables. The SIU 800 is intended for 
use in applications such as TDR circuit board 
testing and cable testing where large static 
charges can be stored. When used with the SD- 
24 TDR/Sampling Head, the SIU 800 provides a 
reflected rise time of less than 40 ps and a reflec- 
tion coefficient of less than 80 millirho. 



120 DIGITIZING OSCILLOSCOPES 



www.tektrofiix.com/Measurement/scopes/ 





Delay Line/Static Isolation Unit/Calibration Step Generator 

DL-11 *SIU 800 



The SIU 800 is installed between the 
DUT and sampling head and is con- 
trolled manually by a foot switch or 
under program control through a TTL- 
compatible input. When the foot switch 
is in the normal position (not pressed), 
the DUT is grounded through a 50 Q 
termination resistor. This will discharge 
any static charge stored in the DUT. 



Pressing the foot switch connects the 
DUT to the sampling head input, allow- 
ing a measurement to be made. Both 
channels are controlled simultaneously 
by the foot switch or TTL input. 



Physical 


Characteristics 




Dimensions 


mm 


in. 


Width 


23.28 


0.95 


Height 


71.05 


2.9 


Depth 


91.39 


3.8 


Weight 


h* 


lbs. 


Net 


0.205 


0.69 


Shipping 


0.441 


2 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



DL-11 

Delay Line. 

Includes: Installation/User Manual (070-7050-01), 
Instruction Sheet (070-7051-01), 20 in. Coaxial Cable, 
RF 50 Q (174-1427-00), 60 in. Coaxial Cable, RF 50 D 
(174-1428-00). 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of Calibration Services. 

Opt. R3 - Repair warranty extended to cover three 
years. 

See page 615 for further information. 



CALIBRATION STEP GENERATOR 
U.S. - Order 067-1338-00. 

Includes: Instruction Sheet Test Report, SMA Female 
Short-circuit Termination. 

Universal Euro - 220 V, 50 Hz - Order 067-1338-01. 
United Kingdom - 240 V, 50 Hz - Order 067-1338-02. 
Australia - 240 V, 50 Hz - Order 067-1338-03. 
Switzerland - 240 V, 50 Hz - Order 067-1338-05. 
Japan - 100 V, 50-60 Hz - Order 067-1338-06. 



SIU 800 

Static Isolation Unit 

Includes: 12 VDC Power Supply, Two SMA, Male-to- 
female Adapters, Foot Switch, Two 50 D, 
Terminators, and an 

Instruction/Performance Verification Manual. 

For your local Tektronix representative see the list in 
the hack of this catalog or outside the U.S. call: 
1-503-627-1916. inside the U.S. call: 1-800-426-2200. 

NOT AVAILABLE IN EUROPE. 

jg ISO 9001 

Tektronix measurement products are manufactured 
in ISO registered facilities. 



www.tektronix.com/Measurement/scopes/ 



DIGITIZING OSCILLOSCOPES 121 





Features - Benefits 



Applications 




Logic Scope 

TLS 216 




2.5 pR 1 MQ Podlet Style FET 
Probes 

Display Modes: Analog, Timing 
Diagram and BusForm"" 

<±100 ps Timing Resolution 
16 Input Channels 

2 GS/s Simultaneous Sampling on 
All Channels 



Hardware Performance Verification 
Multi-channel Data Acquisition 
Mixed Signal Analysis 
A/D and D/A Analysis 
Hardware Timing Analysis 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 

C€ 



ISO 9001 

Tektronix measurement 
products are manufactured in 
ISO registered facilities. 

gSb 

IEEE4U 



Product(s) complies with IEEE 
Standard 488.1-1987, RS-232-C, 
and with Tektronix Standard 
Codes and Formats. 



500 MHz Real-time Bandwidth 

Logic Family Presets for TTL, ECL 
and CMOS 

Sophisticated Time Qualified 
Triggering with Four Word 
Recognizers 

3-Year Warranty 

Facilitates Hands-free Connection 
to SMT Devices 

Low Capacitance Probe for Non- 
Intrusive Probing 

Powerful Triggering Reduces Time 
to Identify Problems 

Flexible Display Modes Simplify 
Recognition of Timing Faults 

High-speed Acquisitions on All 
Channels Facilitate Analysis of 
Complex System Interactions 



TLS 216 Logic Scope 

The TLS 216 Logic Scope is a new class of instru- 
ment designed to simplify the task of debugging 
digital hardware. The Logic Scope seamlessly com- 
bines in a single instrument the analog acquisition 
system of a high-speed digital storage oscilloscope 
(DSO) with the triggering and display systems of a 
logic analyzer. The 500 MHz bandwidth Logic 
Scope samples all channels simultaneously at 2 
GS/s and has sophisticated time-qualified trigger- 
ing, a high resolution color display, and an integrat- 
ed MS-DOS compatible 3.5 inch floppy disk drive. 



Sophisticated Triggering to 
Identify Complex Digital Problems 

In addition to edge trigger, most digital signals 
can be easily captured using pulse, glitch and 
pattern triggers. The Logic Scope provides two 
new trigger resources that allow the instrument 
to directly trigger on common digital circuit 
behavior. The industry’s first time-interval or 
sequence trigger type monitors the time between 
two events, allowing the instrument to easily 
trigger on setup time violations, hold-time viola- 
tions, or unexpected propagation delay. The 



122 LOGIC SCOPE 



www.tektronix.com/Measurement/logic analyzers/ 






Logic Scope 
ns 216 




P6240 



Characteristics 



Signal Acquisition System 

Sample Rate 2 CS/s 



Bandwidth 


500 MHz 


Channels 


16 


Samplers 


16 


Sensitivity 


50 mV to 10 V/div*' 


Position Range 


±5 


Offset 


±1 V from 1 to 99.5 mV/div 



Magnification used above 2 V/div range. 

VERTICAL SYSTEM 



powerful “Time-out” trigger type can be 
used to capture incomolete handshake 
sequenc'^*' le instrument 

whei 

All o ^ developers 

identny ciiaiiiiel-to-channel relationships, 
including 16-Bit patterns and time-relat- 
ed/time-qualified system faults. The Logic 
Scope’s external trigger-input can be used 
as a “Trigger Arm” to enhance cross-trig- 
gering between two instruments, simph- 
fying the task of using a Logic Scope with 
other test equipment. 

2.5 pF, Low-Mass FET Probes 
Ensure Nonintrusive 
Connection 

The Logic Scope includes a set of 16 
specially designed probes that have 
extremely low probe-tip mass (1.5 
grams) and input capacitance (2.5 pF). 
The P6240 low prohe-tip mass ensures 
that connections made to surface mount 
and fine pitch ICs will be reliable. The 
low input capacitance, combined with 
the 1 MO input resistance, decreases 
the effect of the probe on the DUT’s 
operation, allowing very accurate meas- 
urements to be made with confidence. 

These characteristics are made possible 
by using a “podlet-style” probe-tip 
design instead of the “pencil-style” 
design of traditional oscilloscope 
probes. Employing the de facto industry 
standard of 0.1 inch spacing between 
the signal and ground inputs, each 0.1 
inch thick podlet can directly attach to 
the hundreds of readily available 1C 
adapters and clips. 



DC Gain Accuracy - ±1.5% after probe cali- 
bration. 

Vertical Resolution - 8-Bits (256 levels over 
10.24 vertical divisions), 11 -Bits with averaging. 

Analog Bandwidth Selection - 20 MHz and 

full. 

Input Coupling - DC. 

Input Impedance - 50 il with coax adapter, 

1 MQ with probe. 

Maximum Input Voltage - Max nondestruc- 
tive input ±25 V (DC + Peak AC). 

Dynamic Range - +15 V to -12 V with probe. 



TIME Base system 



Time Bases 


Main, Delayed 


Time/Division Range 


500 ps to 5 s/div 


Time Base Accuracy 0.01 % over any interval < 1 ms 


Record Length 


500 to 2,000 pts 


Pre-trigger Position 


20% to 80% of record 



ACQUISITION MODES 
Sample - Sample data only. 

Envelope - Max/mln values acquired over 
one or more acquisitions. 

Average - Waveform averages selectable 
from 2 to 10,000. 

DISPLAY 

Mixed-mode Data Display - Logic Scope 
offers Analog, Timing and BusPorm"** display 
formats that simplify recognition of digital tim- 
ing faults and signal anomalies. BusForm dis- 
play compresses many Input signals into the 
least amount of display area. The acquired 
data can be displayed in any of the three dis- 
play modes without re-acquiring. 

Waveform Style - Dots, vectors, variable per- 
sistence selectable from 250 ms to 10 s, infinite 
persistence and intensified samples. 

Color - Standard palettes and user definable 
colors for waveforms, text, graticules and cur- 
sors. Measurement text and cursor colors 
matched to waveform. Waveform collision 
areas highlighted with different color. Statistical 
waveform distribution shown with color grad- 
ing through variable persistence. 



Color Grading - With variable persistence 
selected, historical timing information is repre- 
sented by temperature or spectral color 
scheme providing "z-axis" information about 
rapidly changing waveforms. 

Graticules - Full, grid, cross hair, frame. 
Format - YT. 

Fit to Screen - Entire acquisition memory 
displayed on screen. 

TRIGGERING SYSTEM 
Triggers - Main, Delayed. 

Main Trigger Modes - Auto, Normal, Single. 
Delayed Trigger - Delayed by time and/or 
events. 

Time Delay Range - 16 ns to 250 s (time/div 
<10 ps); 15.1 ns to 250 s (time/div <25 ps). 
Events Delay Range - 1 to 9,999,999 events. 
AUX Trigger Input - TTL compatible; Max 
input voltage is -1 V to +6 V. 

MEASUREMENT SYSTEM 

The Logic Scope provides a comprehensive suite 
of automatic measurements specifically designed 
to improve efficiency when troubleshooting digi- 
tal hardware. Twenty-eight on-board measure- 
ments, including setup time, hold time and skew, 
speed Identification of common digital problems. 
Whereas traditional DSOs confine waveform 
measurements to establishing the relationship of 
a single channel to a clock, the Logic Scope simul- 
taneously samples on all channels, so you can 
see the relationships between multiple channels. 

Automatic Waveform 
Measurements 



High ... 


Low 


+ Width 


- Width 


Maximum 


Minimum 


Rise 


Fall 


Peak to Peak 


Amplitude 


+ Duty Cycle 


- Duty Cycle 


+ Overshoot 


- Overshoot 


Propagation Delay 


Burst Width 


Mean 


Cyde Mean 


rms 


Cyde rms 


Area 


Cycle Area 


Phase 


Setup Time 


Hold Time 


Skew 



Continuous update of up to four measure- 
ments on any combination of waveforms. 
Gated - Any region of the record may be iso- 
lated for measurement using vertical bars. 
Snapshot - Performs all measurements on 
any one waveform, showing results from one 
instant in time. 



www.tektronix.com/Measurement/logk analyzers/ 



LOGIC SCOPE 123 







Logic Scope 

TLS 216 



Cursor Measurements - Absolute, 

Delta; Volts, Time, Frequency, Binary Readout. 
Cursor Types - Horizontal bars 
(volts); Vertical bars (time); operated inde- 
pendently or in tracking mode. 

COMPUTER INTERFACE 
GPIB (IEEE 488.2) Programmability - Full 
talk/listen modes. Control of all modes, set- 
tings, and measurements. 

HARD COPY/DESKTOP PUBLISHING 
Printer - HP ThinkJet, Epson, PostScript, 
DeskJet, LaserJet, DPU 411/412. 

Export File Formats - EPS (Encapsulated 
PostScript), Interleaf, TIFF, PCX, BMP, RLE. 
Plotter Support - HPCL. 

I/O Ports - GPIB, Centronics, RS-232 (Talk only). 
Floppy Disk Drive - 3.5 in., 1.44 MB DOS 
format. 

VGA Output - 15-Pin analog output (Color). 

STORAGE 

Waveforms - 16 full 2,000 pt waveforms. 
119,008 500 pt waveforms on 1.44 MB floppy 
disk. 

Setups - 10 front-panel setups. 78,947 setups 
on 1.44 MB floppy disk. 

POWER REQUIREMENTS 

Line Voltage Range - 90 to 250 V rms. 

Line Frequency - 47 to 63 Hz. 

Power Consumption - 300 W max. 

ENVIRONMENTAL AND SAFETY 
Temperature - Operating: -t-4°C to +50°C. 
Nonoperating: -22®C to +60°C. 

Humidity - Operating and Nonoperating: 
Operating to 80% at or below 29®C, to 20% 
from +30°C to +50®C. Nonoperating to 90% at 
or below 41 X to 5o/o from +41°C to 50°C. 



Trigger Types 
(Main and Delayed) 

Edge Trigger when either a rising or falling edge (positive or negative slope) is detected. 

Pulse The pulse may be positive or negative and defined by a duration. 

Width (Time) Trigger when the duration of either a positive or negative pulse 

Is less than or greater than the user-defined input 

Range (In Range, Out of Range) Trigger when the duration of either a positive or negative pulse 
Is either between the upper and lower limits or outside the limits. 

Time-out Trigger at the end of a user-defined time period if the trailing edge 

0^ either a positive or negative pulse is not detected. 

Pattern Each input may be defined as a low (logic 0), high (logic 1), or don't care (X). 

Inputs can be ANDed or ORed. The pattern may be positive true or positive false. 
Width (Time) Trigger when the duration of a user-defined logical pattern 

is less than or greater than the user-defined input. 

Range (In Range, Out of Range) Trigger when the duration of a user-defined logical pattern 

Is either between the upper and lower limits or outside the limits. 

Time-out Trigger at the end of a user-defined time period 

if the use r-defined logical pattern of a specified duration does not occur. 

Sequence The sequence is defined by a set of start and end events. 

The start or end event can be either a pattern or an edge (positive or negative slope). 
Width (Time) Trigger when the duration between the user-defined start and end events 

is less than or greater than the user-defined input. 

Range (In Range, Out of Range) Trigger when the duration between the user-defined start and end events 
is either between the upper and lower limits or outside the limits. 

Time-out Trigger at the end of a user-defined time period If the user-defined end event 

does not occur within the speci fied ti me af te r the start event. 

State Trigger when a user-specified logical pattern is detected 

and the input defined as the clock goes true or goes false. 

Each Input may be specified as a low (logic 0), high (logic 1), 

__ or don't care ()Q. Inputs c an be ANDed or ORed.aa 



Altitude - 

Operating: 15,000 ft.. Nonoperating: 40,000 ft. 

Electromagnetic Compatibility - Meets 
89/336/EEC. 

Safety - UL1244, CSA231, EN61010-1, 
IEC61010-1. 

PROBES 

Active Probes - 2.5 pF, 1 MQ FET. 



Physical Characteristics 



Dimensions 


mm 


in. 


Height with feet 


236 


9.3 


without feet 


193 


7.6 


Width with handle 


445 


17.5 


Depth with front cover installed 432 


17 


Weight _ 


kS 


lbs. 


Net approximately 


12.3 


27 


Shipping approximately 


20 


44 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



Opt. is - Substitute 16 Coax Adapters for Standard 
Probes. 



TLS 216 

Logic Scope. 

Includes: 16 each P6240 2.5 pF, FET Probes, 2 each 
Handheld Adapters (013-0281-00), 2 each 7 in. Ground 
Leads (196-3302-00), 2 Packages of 10 each Y-leadsets 
(020-2008-00), 3 Packages of 12 each KlipChip’^ (020- 
1386-01), 2 each 2-to-l Podlet Adapters (013-0280-00), 1 
Package of 6 Probe Cable Looms (352-0139-00), 3 Cards 
of Channel ID Labels (334-8632-00), Instrument Front 
Cover (200-3696-00), U.S. Power Cord (161-0230-01), 
Quick Reference Guide (070-8833-00), User Manual 
(070-8834-00), Programmer Manual (070-8835-00). 

Opt. IB - Package of 16 50 Q. Coax Adapters. 

Opt. IK - K420 Instrument Cart Without Power Strip. 
Opt. 1R - Rackmount Kit. 



Opt. 24 - Four Extra P6240 Probes. 

Opt. 01 - Calibration Data Report. 

INTERNATIONAL POWER PLUGS 
Opt. A1 - Universal Euro 220 V, 50 Hz. 

Opt. A2 - United Kingdom 240 V, 50 Hz. 

Opt. A3 - Australian 240 V, 50 Hz. 

Opt. A4 - North American 240 V, 60 Hz. 

Opt. A5 - Switzerland 220 V, 50 Hz. 

See page 619 for description. 

MEASUREMENT SERVICE OPTIONS 
Opt. IN - Product Installation Service. 

Opt. C3 - Three years of Calibration Services. 

Opt. S3 - Three year upgrade to "On-site" Service. 



PROBES 

FET Probes Only - 2.5 pF, 1 MQ, 800 MHz, 20X, 
1.5m. Order P6240. 

CARTS 

Instrument Cart - Order K420. 

ADDITIONAL ACCESSORIES 

Also see page 495. 

Service Manual - Order 070-8836-00. 

Soft Carrying Case - Order 016-0909-01. 

Hard Transit Case - Order 016-1157-00. 

U.S. Power Strip - Four Outlet, 6 ft., Noise/Surge 
Suppression. Order 131-5342-01. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 



124 LOGIC SCOPE 



www.tektronix.com/Measurement/logic_analyzers/ 




Logic Analyzers 



A New Family of Instruments 

The TLA 700 Series is a new family of instruments developed specifically to address 
the fast-changing needs of today’s digital design engineers. These products bring new 
technology to bear on the time and design pressures faced by digital system designers. 

The TLA 700 Series addresses the needs of the entire digital design team. HW 
developers, HW/SW integrators and embedded SVV developers will all find the TLA 
700 provides solutions for those elusive problems that threaten their product devel- 
opment schedules ranging from analog signals to HLL source code. 

► Source Code Support: See page 128 

► Performance Analysis Support: See page 128 

► Repetitive Acquisition wdth Memory Comparison: See page 129 

► Remote Control with Support for Advanced Data Analysis: See page 129 

► Processor and Bus Supports: See page 137 

TLA 700 Series Logic Analyzer Modules 

The TLA 700 Series includes a wide selection of logic analyzer modules with 
measurement capabilities not seen in logic analyzers before. 

MagniVu™ Acquisition Technology: A Breakthrough for 
Logic Analyzers 

At the heart of all the TLA 700 Series logic analyzer modules is a breakthrough 
called MagniVu acquisition technology. MagniVu acquisition technology is a super 
high-speed sampling architecture that dramatically changes the way logic analyzers 
work and what functionality they offer. 



World-Class DSO Modules 

The TLA 700 Series offers a range of DSO modules that provide the acquisition capa- 
bilities of the world’s best DSOs. tightly integrated with the TLA 700 logic analyzers. 

Mainframes that Establish a Platform for the Future 

The TLA 700 Series mainframes offer a new paradigm for Logic Analyzers. Instead 
of building a proprietary compute engine into an instrument, Tektronix built-in an 
industry-standard computer and operating system. 

Open Platform: The TLA700 Series Logic Analyzer Allows 
Flexibility and Interoperability of Embedded Systems Tools. 

Tektronix and its Embedded Systems Tools Partners provide a wide range of devel- 
opment products, debug products, and services for developers. Tektronix provides 
logic analyzers, oscilloscopes, and other instrumentation. Partners provide proces- 
sors, microprocessors, DSPs, processor development and evaluation boards, operat- 
ing systems, software development tools, emulators, software debuggers, logic ana- 
lyzer processor/bus supports, probe and interconnects adapters, protocol analyzers, 
instrument control hardware and software, and other products used in embedded 
systems design and debug. 



Embedded Systems Tools Partners 



Applied Microsystems Corp. 

ARM Ltd. 

CAD-UL, Inc. 

CATC - Computer Access Technology 
Corp. 

Cogent Computer Systems, Inc. 
Crescent Heart Software, Inc. 

EST - Embedded Support Tools Corp. 
ET - Emulation Technology, Inc. 
Green Hills Software, Inc. 

Hitex Development Tools 
Ingenieurbuero Strunck 



Ironwood Electronics, Inc. 
Macraigor Systems, Inc. 
Mentor Graphics Corp., 
Microtec Division 
National Instruments Corp. 
New Wave PDG 
Orion Instnunents 
TASKING, Inc. 

Temic MHS 

TERA Technologies, Inc. 

U S Software Corp. 

Wind River Systems, Inc. 



Contents 

Modules 126 

Mainframes 129 

Microprocessor Support 137 

Probes 134 

Carts 582 



www.tektronix.com/Measurement/logic_analyzers/ 



LOGIC analyzers 



125 




Logic Analyzers 

TLA 700 Series New TLA 714 • New TLA 720 




Features - Benefits Applications 



MagniVu^ Acquisition Technology 
Provides 500 ps Timing Resolution 
on All Channels All the Time 
Through a Single Probe 

200 MHz State Acquisition Supports 
Advanced Processors and Buses, 
250 MHz Timing Acquisitions 

400 MHz Data Rate 

Up to 16 Mbits Per Channel with 
Hardware - Accelerate Waveform 
Display and Search Functions 



Hardware Debug and Verification 

Embedded Software Integration, 
Debug and Verification 

Embedded Real-Time Software 
Optimization 

System Validation 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1 - 503 - 627 - 1916 , 
inside the U.S. call: 
1 - 800 - 426 - 2200 . 



CC 

iso 9001 

Tektronix measurement 
products are manufactured in 
ISO registered facilities. 



A New Family of Instruments 

The TLA 700 Series is a new family of instru- 
ments developed specifically to address the fast- 
changing needs of today’s digital design engi- 
neers. These products bring new technology to 
hear on the time and design pressures faced by 
digital system designers. 

The TLA 700 Series addresses the needs of the 
entire digital design team. HW developers, 
HW/SW integrators and embedded SW develop- 
ers will all find the TLA 700 provides solutions 
for those elusive problems ranging from analog 
signals to HLL source code that threaten their 
product development schedules. 

The family consists of portable and benchtop 
mainframes, logic analyzer modules, DSO mod- 
ules, and a full line of complementary support 
products for popular microprocessors and buses. 

TLA 700 SERIES LOGIC ANALYZER MODULES 

The TLA 700 Series includes a wdde selection of 
logic analyzer modules with measurement capa- 
bilities not seen in logic analyzers before. 

MAGNIVU ACQUISITION TECHNOLOGY - 
A BREAKTHROUGH FOR LOGIC ANALYZERS 

At the heart of all of the TLA 700 Series logic 
analyzer modules is a breakthrough called MagniVu 



acquisition technology. MagniVu acquisition tech- 
nology is a super-high-speed sampling architecture 
that dramatically changes the way logic analyzers 
work and what functionality they offer. 

All incoming data is oversampled at a 2 GHz 
rate, regardless of how the logic analyzer is 
being used. The oversampled data is then 
processed in real time to perform timing acquisi- 
tion, state acquisition, and triggering without 
missing the slightest piece of crucial timing 
information on any channel. 

MagniVu Acquisition technology makes it possi- 
ble to offer the following measurement capabili- 
ties that logic analyzer users have long needed: 

500 ps Timing Resolution on All Channels. By 
Storing timing information in MagniVu acquisi- 
tion technology’s high-speed memory at the full 
2 GHz rate, all TLA 700 Series logic analyzers 
are able to offer 500 ps timing resolution on all 
channels, all the time. 

Up to 200 MHz State Acquisition. TLA 700 
Series modules offer standard configurations 
with state acquisition up to 100 MHz for com- 
mon applications and optional 200 MHz configu- 
rations for leading-edge applications. 



126 LOGIC ANALYZERS 



www.tektronix.com/Measureinent/logic_analyzers/ 






Logic Analyzers 

TLA 700 SERIES 




TLA 720 - Both the portable TLA 714 and the 
benchtop TLA 720 combine impressive per- 
formance and a modem graphical user inter- 
face to simplify debugging complex system 
problems and enable engineering teams to 
meet or exceed their development schedules. 




From right: The 34-CH, 68-CH, 102-CH, and 
136-CH Logic Analyzer modules; available 
with depths up to 16 Mbits per channel with 
your choice of probes. A TLA 720 benchtop 
mainframe can hold up to five modules for a 
total system of 680 channels. 

Since all clocks and data are oversam- 
pled at a 2 GHz rate and processed in 
real time to provide 200 MHz synchro- 
nous acquisition, each data sample is 
timestamped with 500 ps resolution. 

User-selectable Setup-and-hold 
Window. Because TLA 700 Series logic 
analyzers always oversample incoming 
data at a 2 GHz rate, they are able to 
provide unmatched state acquisition 
capabilities as well. The combined 
setup-and-hold time window required 
across up to 136 channels is typically 
only 2.0 ns and can be placed anywhere 
from 8.5 ns before the selected clock 




The graphical user interface can display an 
almost unlimited number of data windows. 
In the above disassembly window, proper- 
ties such as column width or text size and 
color can be easily changed by the user. 

Note the timestamp with 500 picosecond 
resolution. 

edge to 7.0 ns after the clock edge, in 
500 ps increments. 

If your design involves sections of cir- 
cuitry with different timing require- 
ments or even mixed logic families, 
that’s no problem for the TLA 700 
Series; you can set different setup-and- 
hold time characteristics and unique 
threshold settings for different groups 
of channels. 

Simultaneous State and Timing 
Analysis Through the Same 
Probes. The logic analyzer modules are 
able to provide both timing analysis 
and state acquisition simultaneously. 
They provide 500 ps timing AND up to 
200 MHz state acquisition at the same 
time, through the same probes. 

You no longer have to hook up a sec- 
ond set of probes and timing modules 
to a bus you’re already acquiring state 
data from. No more running out of tim- 
ing channels because you didn’t have 
enough modules or couldn’t fit them 
into your mainframe. No tradeoffs of 
channels or important features to get 
the results you need. 

Precision Triggering on Setup-and-hold 
Violations and Glitches. Each logic ana- 
lyzer module has the ability to trigger 
on very precise timing problems. 
Whether timing problems are suspect, 
or things seem to be working and you 
need to test for design margins, tlie TLA 
700 Series triggering does what no 
other logic analyzer can. 

The TLA 700 Series can trigger on 
setup-and-hold time violations on any 




Using the Magnitude Mode feature in the 
Waveform Window, you can view the value 
of your acquired data versus time. This is 
particularly useful for A/D and D/A applica- 
tions, such as viewing the RGB components 
of a digitized video signal. 

or all groups of channels with 500 ps 
resolution. You can select different tim- 
ing limits for different groups and even 
verify propagation delay from clock-to- 
output of synchronous circuits. 

Not even glitches can escape the watch- 
ful eye of the TLA 700 Series; because 
the glitch detection logic is processing 
the same oversampled data. ANY set of 
two or more transitions between sample 
points on any channel is captured and 
can be used for glitch triggering. 

What-You-See-Is-What-You-Triggered- 
On! The greatest benefit that oversam- 
pling brings to triggering is that the pre- 
cise timing of whatever condition you 
trigger on is fidly visible with MagniVu 
technology. This means that when you 
trigger on a setup-and-hold time viola- 
tion on a 64-Bit data bus, you can 
immediately view all 64 channels to see 
exactly which signals caused the viola- 
tion and how far those signals were 
beyond the limits you specified. 

WORLD-CLASS DSO MODULES 

The TLA 700 Series offers a range of 
DSO modules that provide the acquisi- 
tion capabilities of the world’s best 
DSOs, tightly integrated with the TLA 
700 logic analyzers. 

Tektronix wrote the book on oscillo- 
scopes and Digital Real-Time^'’ (DRT) 
technology, which brings the band- 
width of leading analog oscilloscopes to 
single-shot digital applications. The 
2- and 4-channel DSO modules avail- 
able in the TLA 700 Series offer sample 



www.tektronix.com/Measurement/logic_anaiyzers/ 



LOGIC ANALYZERS 127 




MagniVu™ - A 64-Bit data bus and its clock 
signal acquired with MagniVu technology, 
showing that the bus takes about 3 ns to set- 
tle when the value changes. Some individual 
data signals are shown also, including the 
first and last to change. The clock signal and 
the slowest data signal are shown as 
acquired by the DSO. 



rates of up to 5 GS/s and bandwidths of 
up to 1 GHz, with 15 K record length, 
on all channels at all times. 

The DSO modules offer precise time 
correlation and flexible cross-triggering 
with the other installed modules. This 
enables you to see the quality of critical 
signals alongside the digital behavior 
they affect. 

LOGIC AND TIME-DOMAIN ANALOG 
FAULT TRIGGERING 

The DSO modules offer the kind of trig- 
gering you expect from a Tektronix 
DSO: Pulse Width, Runt, Glitch, Slew 
Rate, Logic Pattern, Setup-and-Hold 
Violation, Edge, and Timeout. All trigger 
modes can be fully time-qualified for 
any period from 2 ns to 1 s and are easi- 
ly set up with a graphical user interface. 

SOURCE CODE SUPPORT 

The HLL Source Code Support post- 
processes real-time trace data acquired 
from processors and buses and auto- 
matically correlates it with your high- 
level language source code. It uses the 
information provided in the object file 
from your compiler to build a data- 
base of source files, line numbers and 
symbolic information. 

Every time you acquire real-time data 
with yoiu* logic analyzer, you can view 
the acquired data disassembled in the 
Listing Window, which shows how 
your code was executed in native 



128 LOGIC ANALYZERS 




TLA7E1 and TLA7E2 

From left: The 2-channel and 4-channel DSO 
modules, shown with P6245 FET probes, are 
available with either 500 MHz or 1 GHz 
real-time bandwidth. 



assembly language, or at the source 
code level in the Source Window, 
which shows your code as written in 
the high level language you use. You 
can ‘step’ forward or backward through 
your source code and view the underly- 
ing assembly code or vice versa, using 
the global cursors. All lines in the 
Listing Window are highlighted that 
correspond to a particular line of source 
code in the Source Window, rather than 
using just the cursor as the indicator. 
Multi-processor and bus systems are 
supported via multiple Source and 
Listing Windows, all automatically 
time-correlated. 

The HLL Source Code Support is a non- 
intrusive tool that does not require you 
to instrument your source code. It is a 
universal tool that supports any high- 
level language whose software tools 
produce supported object file formats. 
No modifications or recompilation of 
your source code is required. 

PERFORMANCE ANALYSIS SUPPORT 

The Performance Analysis Support gen- 
erates statistical representations by 
postprocessing real-time data acquired 




Data acquired by all instrument modules is 
preci.sely lime correlated. You can now easily 
see when signal quality causes timing faults. 




The 2-channel and 4-channel DSO modules 
have the performance to accurately capture 
signal quality and small glitches. A maxi- 
mum of 20 1 GHz DSO channels is possible 
using the TLA 720 mainfi'ame. 

from processors and buses connected to 
the logic analyzer module and display- 
ing the results in a histogram format. 
You can view the results acquired by 
three different methods: 

► Group: Select a channel Group such 
as Address, setup your ranges either 
manually or automatically by load- 
ing symbols from your object mod- 
ule and press Run to monitor the 
number of hits against each range. 

► Counter: Select a Counter, setup the 
count intervals either linearly or log- 
arithmically and press Run to moni- 
tor the varying number of counts 
over multiple acquisition. 

► Timer: Select a timer, setup the time 
intervals either linearly or logarith- 
mically and press Run to monitor 
the varying time (with 4 ns resolu- 
tion) over multiple acquisitions. 



www.tektronix.com/Measurement/logic analyzers/ 







Logic Analyzers 

TLA 700 SERIES 




View processor trace data tightly time-corre- 
lated with your high-level source code using 
the information provided in the object file 
from your software development environ- 
ment. Tektronix disassemblers automatically 
filter out unexecuted code fetches. 

The Performance Analysis Support is a 
non-intrusive tool that does not require 
you to instrument your source code. No 
modifications or recompilation of your 
source code is required. 

You can sort the display in either ascend- 
ing or descending order. You can also 
export the results for further analysis. 

The Performance Analysis Support uti- 
lizes the same symbols in the TLA 700’s 
symbolic database. 

REPETITIVE ACQUISITION WITH 
MEMORY COMPARISON 

Repetitive Acquisition allows the TLA 
700 to repeatedly acquire data from 
your target system and perform a vari- 
ety of operations depending upon the 
comparison results. At each iteration, 
you can either save the results and 
restart or stop and send a command to 
the Windows 98 operating system that 
could send email or page you. Then, 
you can save the results, concatenate to 
a single file or specify that each new 
file has the filename autoincremented. 

Repetitive Acquisition with Memory 
Comparison compares the results of two 
independent LA acquisitions and high- 
lights the differences in either Listing 
or Waveform Windows. You can specify 
the range of samples over which to 
make the comparison or specify the off- 
set between the two acquisition memo- 
ries. You can also mask or prevent 
channels from being compared. 



www.tektronix.com/Measurement/logic_analyzers/ 




Extensive remote control command set 
based upon Microsoft COM/DCOM technolo- 
gy interfaces seamlessly with advanced 
Windows applications such as Excel or 
Visual Basic to provide advanced data 
analysis. Quickly develop powerful data 
analysis capabilities using the TLA 700 as a 
high-performance data acquisition device, 
either directly on the TLA 700 or over the 
network on a remote computer. 



Now you can setup your TLA 700 to 
continuously monitor your target sys- 
tem, thereby freeing you up for other 
tasks and notifying you only when 
there’s an anomaly. 

REMOTE CONTROL WITH SUPPORT 
FOR ADVANCED DATA ANALYSIS 

Although remote control has been a stan- 
dard feature in logic analyzers, the TLA 
700, being based upon an open, embed- 
ded PC running Microsoft Windows 98, 
provides a new capability that is a first 
for logic analyzers. Using the Microsoft 
Windows Component Object Model 
(COM/DCOM) technology, the TLA 700 
Programmatic Interface (TPI) provides 
the next-generation technology for LA 
remote control. The TPI provides a mod- 
ern ‘function call’ interface that is com- 
patible with COM/DCOM programmatic 
interfaces of other Windows applications. 

Support for non-Windows platforms 
(e.g., UNIX) is available via Distributed 
COM (DCOM) from 3rd parties. 

Now with the TPI, you can spend less 
time trying to build advanced data 
analysis from scratch and instead use 
existing Windows applications such as 
Microsoft Excel or Microsoft Visual 
Basic or C-h-i- to build an advanced data 
analysis application that seamlessly 



integrates with the TLA 700. You can 
then run your application directly on the 
TLA 700 or from a computer connected 
over a LAN connected to your TLA 700. 

MAINFRAMES THAT ESTABLISH A 
PLATFORM FOR THE FUTURE 

The TLA 700 Series mainframes offer a 
new paradigm for test instrumentation. 
Instead of building a proprietary com- 
pute engine into an instrument, 
Tektronix uses an industry-standard 
computer and operating system. You 
can install industry leading software 
debuggers and run control on the 
TLA 700 series to download and run 
code on your target. 

Both the portable TLA 714 and the 
benchtop TLA 720 use Microsoft 
Windows 98. That means that you don’t 
have to spend time learning how to 
navigate the user-interface because it 
works just like other PC-based software 
you’ve used. Because Windows 98 is 
fully integrated and embedded when 
you open the box, you get the benefit of 
a familiar environment without having 
to set things up yourself. This allows 
you to concentrate on the problem 
you’re solving rather than the tool 
you’re using. 

You also don’t have to worry about how 
to integrate the TLA 700 into your test 
environment. Any accessories you can 
buy that connect a portable PC into your 
environment can be used directly on 
TLA 700 Series mainframes. Standard 
USB, PS2 mouse & keyboard, serial, par- 
allel, SVGA, and PC Card, (Card Bus 32) 
interfaces are used for external acces- 
sories. The TLA 700 Series comes stan- 
dard with a 3.5 in. floppy, CD-ROM and 
removeable hard drive. 

THE TPI SUPPORTS THE FOLLOWING 
REMOTE OPERATIONS: 

System: Configuration, Load/Save, Run 

Control, Stat^^^^^ 

LA Module: Load/Save, Trigger Setup, 

Acquisition Data & Parameters 

DSO Module: Load/Save, Acquisition 

Data & Paramet ers 

All modules, software, and accessories 
are fully interchangeable between 
portable and benchtop mainframes. 



LOGIC ANALYZERS 129 




Logic Analyzers 

TLA 700 SERIES 




The TLA 714 includes PC card slots with 
Card Bus 32 support (two (2) Type II or one 
(1) TVpe III) and standard PC I/O - SVGA, 
parallel printer, and RS-232. Optional LAN 
card shown installed. 




TLA 714 with replaceable hard drive. 



Characteristics 



LA Module 

GENERAL 

Number of Channels per Module (all 
channels are acquired including clocks) - 

TLA 7N1 : 34 channels (2 are clock/qual 
channels). 

TLA 7N2, TLA 7P2: 68 channels (4 are 
clock/qual channels). 

TLA 7N3: 102 channels (4 are clock/qual and 
2 are qual channels). 

TLA 7N4, TLA 7P4: 136 channels (4 are 
clock/qual and 4 are qual channels). 

Channel Grouping - No limit to number of 
groups or number of channels per group (all 
channels can be reused in multiple groups). 




The TLA 720 includes PC card slots with 
Card Bus 32 support (two (2) Type II or one 
(1) TVpe III) and standard PC I/O - SVGA, 
parallel printer, and RS-232. 




TLA 714 - The portable TLA 714 includes a 
standard protective hard cover, accessory 
pouch, and integral carrying handle. 



Module "Merging" - Three 102-CH or 
136-CH modules can be "merged" to make up 
to a 408 CH module. Merged modules exhibit 
the same depth as the lesser of the three indi- 
vidual modules. Word/range/setup-and- 
hold/glitch/transition recognizers span all three 
modules. Only one set of clock connections is 
required. 

Time Stamp - 50-Bits at 500 ps resolution 
(6.5 day range). 

Clocking/ Acquisition Modes- State, timing, 
simultaneous. 

Number of Mainframe Slots Required - 2. 




Both the TLA 714 (shown) and the TLA 720 
have CD-ROM and replaceable hard drives. 



INPUT CHARACTERISTICS (WITH 
P6417, P6418 OR P6434 PROBES) 
Capacitive Loading - 

1.4 pf typical (P6418). 

2 pf typical (P6417 & P6434). 

Threshold Selection Range - From +5.0 V 
to -2.0 V in 50 mV increments. 

Threshold Selection Channel 
Granularity - Separate selection for clock (1) 
and data (16) for each 17-CH probe connector. 
Threshold Accuracy (including probe) - 
±100 mV. 

Input Voltage Range - 

Operating: 8 Vp.p centered around the pro- 
grammed threshold. 

Non-destructive: ±15 V. 

Input Signal Swing (probe overdrive) - 

±250 mV or ±25% of signal swing, whichever 
is greater. (P6417 & P6418) 

±300 mV or ± 25% of signal swing (P6434). 

Input Signal Minimum Slew Rate - 

200 mV/ns typical. 

STATE ACQUISITION 
CHARACTERISTICS (WITH P6417, 

P6418 OR P6434 PROBES) 

Maximum Synchronous Clock Rate - 

100 MHz standard, 200 MHz optional. 

Maximum Data Rate (Half Channels) - 
400 MHz, typical. Requires 200 MHz option. 
State Memory Depth - 64 K, 256 K, 1 M, 

4 M or 16 M bits per channel. 

Setup Time Selection Range - From 8.5 ns 
before to 7.0 ns after clock edge. 
Setup-and-hold Window - 2.0 ns typical. 
Minimum Clock Pulse Width - 2 ns. 

Active Clock Edge Separation - 5 ns. 
Demux Channel Selection - 32 channels can 
be demultiplexed to other channels by user. 



130 LOGIC ANALYZERS 



www.tektromx.com/Measurement/logic_analyzers/ 








Logic Analyzers 

TLA 700 SERIES 



TIMING ACQUISITION 
CHARACTERISTICS (WITH P64I7, 
P6418 OR P6434 PROBES) 

Main Timing Resolution - 4 ns to 50 ms. 
Main Timing Resolution with Glitch 
Storage Enabled - 10 ns to 50 ms. 

Main Timing Memory Depth (with or 
without transitional storage enabled) - 
64 K, 256 K, 1 M, 4 M or 16 M per channel. 
Main Timing Memory Depth with Glitch 
Storage Enabled - Half of default main 
memory depth. 

MagniVu"^ - 500 ps. 

MagniVu Timing Memory Depth - 2 Kbits 
(2048) per channel. 

Channel-to-channel Skew - <1 ns typical. 
Minimum Recognizable Pulse Width 
(single channel) - 2 ns. 

Minimum Recognizable Glitch Width 
(single channel) - 2 ns. 

Minimum Recognizable Multi-channel 
Trigger Event - Sample period + 2 ns. 

TRIGGER CHARACTERISTICS 
Independent Trigger States - 16. 

Maximum Independent If/then Clauses 
per State - 16. 

Maximum Number of Events per If/then 
Clause - 8 . 

Maximum Number of Actions per If/then 
Clause - 8 . 

Maximum Number of Trigger Events - 

18 counter/timers plus any 16 other resources. 
Number of Word Recognizers - 16. 
Number of Range Recognizers - 4. 

Number of Counter/Timers - 2 . 

Trigger Event Types - Word, group, channel, 
transition, range, anything, counter value, timer 
value, signal, glitch, setup-and-hold violation. 
Trigger Action Types - Trigger module, trig- 
ger all, store, don't store, start store, stop store, 
increment counter, reset counter, start timer, 
stop timer, reset timer, goto state, set/clear sig- 
nal, do nothing. 

Trigger Sequence Rate - DC to 250 MHz 

(4 ns). 

Counter/Timer Range - 51 -Bits each (>100 
days @ 4 ns). 

Counter Rate - DC to 250 MHz (4 ns). 

Timer Clock Rate - 250 MHz (4ns). 
Counter/Timer Latency - None (can be test- 
ed or reset immediately after starting). 

Range Recognizers - Double bounded (can 
be as wide as any group, must be grouped 
according to specified order of significance). 
Setup-and-hold Violation Recognizer 
Setup Time Range - From 8 ns before to 
7 ns after clock edge in 0.5 ns increments. 
Setup-and-hold Violation Recognizer Hold 
Time Range - From 7 ns before to 8 ns after 
clock edge in 0.5 ns increments. 



www.tektronix.com/Measurement/logic_analyzers/ 



Trigger Position - Any data sample. 
MagniVu"" Trigger Position - MagniVu data 
is centered around the module trigger. 
Storage Control (data qualification) - 
Global (conditional), by state (start/stop), by 
trigger action, or transitional. 

Storage Window Granularity - Single sam- 
ple or block-of-31 samples before and after. 

Physical Characteristics 

Dimensions mm in. 



Height 


262 


10.3 


Width 


61 


2.4 


Depth 


381 


15 


WeigM 




lb. 


Net 


3.1 


6.7 


Shipping 


6.3 


13.7 



P6417 Probe Cable Length - 1.8 m (6 ft ). 
P6418 Probe Cable Length - 1.8 m (6 ft.). 
P6434 Probe Cable Length - 1.5 m (5 ft.). 



DSO Modules 

GENERAL 

Number of Channels per Module - 

TLA 7D2, TLA 7E2: 4 channels. 

TLA 7D1, TLA 7E1: 2 channels. 

Sample Rate - 

TLA 7E1, TLA 7E2: 5 GS/s on all channels. 

TLA 7D1, TLA 7D2: 2.5 GS/s on all channels. 

Bandwidth (at probe tips) - 

TLA 7E1, TLA 7E2: 

100 mV to 10 V range: 1 GHz. 50 mV to 99.8 
mV range: 900 MHz. 20 mV to 49.8 mV range: 
600 MHz. 

All others: 

500 MHz. TLA 7D1, TLA 7D2: 500 MHz on all 
channels in all ranges. 

Memory Depth - 

15,000 samples per channel in ail modes. 

Number of Mainframe Slots 
Required - 2 . 

VERTICAL SYSTEM 

Input Sensitivity Range - 10 mV to 100 V 

full scale. 

Vertical Resolution - 8-Bits (256 levels). 

DC Gain Accuracy - ±1.5% of full scale range. 
Analog Bandwidth Selections - 20 MHz, 

250 MHz, and Full. 

Input Coupling - AC, DC, or GND. 

Input Impedance Selections - 1 MQ in par- 
allel with 10 pf, or 50 Q. 

AC Coupled Lower Frequency Limit - 
<10 Hz when AC 1 MQ, coupled, <200 kHz 
when AC 50 Q. coupled. 

Maximum Input Voltage at Probe 
Connector - 300 VRMS, but no greater than 
±420 V peak (1 MQ or ground input coupling). 



PROBE INPUT CHARACTERISTICS 
Probe Input Interface - TEKPROBE” probe 
interface. 

Input Loading - Less than 1 pf in parallel 
with 1 MQ with either P6243 or P6245. 

Usable Input Voltage Range at Probe Tip - 

P6243 Probe: ±8 V. 

P6245 Probe: ± 18 V. 

ACQUISITION SYSTEM 

Sample Rate Range - 200 ps to 200 ms in 

1, 2.5, 5 sequence. 

Timebase Accuracy - ±100 ppm over any 
interval >lms. 

Record Length Range - 512 to 15,000 sam- 
ples per channel in ail modes. 

Acquisition Modes - Single-shot, repetitive. 

TRIGGER SYSTEM 
Trigger Modes - Normal, auto. 

Trigger Position - Anywhere in the acquired 
record (pre-fill can be set anywhere from 0% 
to 100%). 

Trigger Types - Edge, pulse width, timeout, 
glitch, runt, slew rate, logic pattern, setup-and- 
hold violation. 

Trigger Actions - Trigger, trigger ail, set sig- 
nal, arm, immediate, wait for system trigger. 




Edge Trigger - Conventional level driven trig- 
ger, positive or negative slope, on any channel 
or external trigger input. Coupling Selections: 
DC, AC, noise reject, HF reject, LF reject. 

Pulse Width Trigger - Trigger on width of 
positive or negative pulse, either within or not 
within selectable time limits; settable from 2 ns 
to 1 s. 



Timeout Trigger - Triggers when a pulse fails 
to complete when specified; settable from 2 ns 
to 1 s. 




Glitch Trigger - Trigger on (or reject) glitches 
of positive, negative, or either polarity; settable 
from 2 ns to 1 s. Minimum glitch width: 2.0 ns, 
with 200 ps resolution (2 ns to 10 ns settings). 



LOGIC ANALYZERS 131 



Logic Analyzers 

TLA 700 SERIES 




Runt Pulse Trigger - Trigger on a pulse that 
crosses one threshold but fails to cross a sec- 
ond threshold before crossing the first again; 
settable from 2 ns to 1 s. 




Slew Rate Tri^er - Trigger on pulse edge 
rates that are either faster or slower than a set 
rate, edges can be rising, falling, or either; set- 
table from 2 ns to 1 s. 




Logic Pattern Trigger - Triggers when a logi- 
cal combination (AND, OR) of all the Input 
channels (Hi, Lo, Don't Care) stays true or false 
for a specified period of time; settable from 2 
ns to 1 s. 

3E±3E 

; T T ; 

Setup-and-hold Trigger - Trigger on viola- 
tions of both setup time and hold time 
between clock and data which are on separate 
input channels; setup time settable from -100 
ns to +100 ns in 200 ps increments; hold time 
settable from -1 ns to +102 ns; minimum set- 
table window of setup time + hold time is 2 ns. 

Physical Characteristics 

Dimensions mm in. 



Height 


262 


10.3 


Width 


61 


2.4 


Depth 


381 


15 


Weight kc lb. 


Net 


2.7 


5.8 


shipping 


5.8 


12.8 



Safety - UL3111-1, CSAIOIO.I, EN61010-1, 
IEC61010-1. 

P6243 Probe Cable Length - 1.3 m (51 in.). 
P6245 Probe Cable Length - 1.3 m (51 in ). 
Other Compatible Probes - P6139A, P6204, 
P5100, P6205, P6408, P6563A, P6701B, P6703B, 
AM 503S, TCP202, P6247, P6248, P6249. 

Mainframe 

PC CHARACTERISTICS (TLA 714 AND 
TLA 720) 

Operating System - Windows 98. 

Processor - 266 MHz Pentium. 



DRAM - 

64 MB SDRAM (128 MB with OpLlS) [TLA 714]. 
128 MB SDRAM [TLA 720]. 

Second-Level Cache - 512 KB pipeline burst 
cache with writeback. 

Display Memory - 2 MB. 

Sound - Built-In PC speaker transducer; 
multimedia sound can be added via PC Card 
interface. 

Replaceable Hard Disk Drive - 2.1 GB (6.4 
GB with Opt.lS) [TLA 714]. 6.4 GB [TLA 720]. 

A second internal fixed hard disk available with 
TLA7UP Opt. 04. 

CD Rom - 24x, Internal. 

Floppy Disk Drive - Built-in 3.5 in. 

1.44 MB drive. 

Year 2000 Compliant - Yes. 

INTEGRAL CONTROLS (TLA 714 ONLY) 
Front-Panel Display - Size: 10.4 In. diagonal. 
Type: Active-matrix color TFT LCD with 
backlight 

Resolution: 800 x 600. 

Colors: 16.8 M (true color). 

Simultaneous Display Capability - Both the 
front-panel and external displays can be used 
simultaneously at 800 x 600 resolution. 
Front-panel Knobs - Special function knobs 
for instrument control. 

Front-panel Qwerty Keypad - Mini-QWERTY 
keypad and Hex keypad. 

Front-panel Pointing Device - Glidepoint 
finger pad. 

External Peripheral 
Interfaces (TLA 714 and 
TLA 720) 

External Display Port Type - 15-Pln sub-D 
SVGA connector. 

External Display Resolution - Up to 1600 x 
1200 NI @ 256 colors. 

External Display Compatibility - DDC2B 
(Dynamic Display Configuration 2). 

External Keyboard Port Type - PS2 

mini-DIN. 

External Mouse Port Type - PS2 mini-DIN. 
Parallel Interface Port Type - IEEE 1284-C 
connector (comes standard with adapter to 
female DB25 connector). 

Parallel Interface Modes - Centronics 
mode, EPP (Extended Parallel Port), ECP 
(Microsoft high-speed mode). 

Serial Interface Port Type - Male DB9. 

PC Card (Card Bus 32) Slot Types - Two 
slots, two PC Card Type I/ll or one PC Card 
Type III. 

USB Port - Two (2). 



EXTERNAL INSTRUMENTATION INTER- 
FACES (TLA 714 AND TLA 720) 

System Trigger Output - Asserted whenever 
a system trigger occurs (TTL-compatible out- 
put, back-terminated into 50 Q). 

System Trigger Input - Forces a system trig- 
ger (triggers all modules) when asserted (TTL- 
compatible, edge-sensitive, falling-edge 
latched). 

External Signal Output - Can be used to 
drive external circuitry from a module's trigger 
mechanism (TTL-compatible output, back-ter- 
minated into 50 Q). 

External Signal Input - Can be used to pro- 
vide an external signal to arm or trigger any or 
ail modules (TTL-compatible, level-sensitive). 

Instrument Slots - 

TLA 714: Holds 4 single-wide or 2 double-wide 
modules. 

TLA 720: Holds 10 single-wide or 5 double- 
wide modules. 

SYMBOLIC SUPPORT 
Number of Symbols/Ranges - Unlimited 
(limited only by amount of virtual memory 
available on TLA 700). 

Object File Formats Supported - 

► IEEE695 

► OMF 51, OMF 86, OMF 286, OMF 386 

► COFF 

► Elf/Dwarf 

► Elf/Stabs 

► TSF (if your software development tools do 
not generate output in one of the above 
formats, TSF or the Tektronix symbol file, a 
generic ASCII file format is supported. The 
generic ASCII file format is documented in 
the TLA 700 User Manual). If a format is 
not listed, please contact your local 
Tektronix representative. 

POWER 
TLA 714 - 

Voltage range/frequency: 90-250 VACRMS 
@ 45-66 Hz and 100-132 VACRMS 
@ 360-440 Hz. 

Input current: 6 A maximum at 90 VAC 
(70 A surge). 

Power consumption: 600 W maximum. 

TLA 720 - 

Input voltage: 90-250 VACRMS @ 45-66 Hz, 
100-132 VACRMS @ 360-440 Hz. 

Input current: 15 A maximum at 90 VAC 
(70 A surge). 

Power consumption: 1350 W maximum. 



132 LOGIC ANALYZERS 



www.tektrofiix.com/Measurement/logic_aiialyzers/ 



Logic Analyzers 

TLA 700 SERIES 




16.7 in 
(42.55 cm) 



r 

13.65 in 
(35.00 cm) 



13.25 in 
(33.6 cm) 







Physical Characteristics 

TLA 714 Portable 



Dimensions 


mm 


in. 


Height 


235 


9.25 


Width 


432 


17.0 


Depth 


455 


17.5 


Weight 


k* 


ib. 


Net (w/o modules) 


11.4 


25 


Shipping (typical) 


25.5 


56 


TLA 720 Benchtop 


Dimensions 


mm 


in. 


Height 


362 


14.25 


Width 


426 


16.75 


Depth 


673 


26,5 


Weight 


>« 


ib. 


Net (w/o modules) 


22.7 


50 


Shipping (typical) 


51.8 


114 



P6041 External Signal Cable Length - 

1.1 m (42 in.). 

ENVIRONMENTAL 
Temperature - 

Operating: +5X to +50®C. 

Non-operating: -20X to +60®C. 

Humidity - 

20% to 80%. 

Operating: <30®C; 80o/o relative humidity (29®C 
maximum wet bulb temperature). 
Non-operating: 8% to 80% (29®C maximum 
wet bulb temperature). 

Altitude - 

Operating: -1,000 ft to 10,000 ft. 

Safety - UL3111-1, CSAIOIO.I, EN61010-1, 
IEC61010-1. 



your local Tektronix representative, inside the U.S. see 

Opt. 1A - Add LAN PC Card (119-6072-00). 

Opt. IM - Add 17-in. monitor (119-5430-00). 

Opt. 2M - Add 21 -in. monitor (119-5422-00). 

Opt. IK - Add LA Cart logic analyzer cart. 

INTERNATIONAL POWER PLUGS 
Opt. A1 - Universal Euro 220 V; 50 Hz. 

Opt. A2 - UK 240 V; 50 Hz. 

Opt. A3 - Australian 240 V; 50 Hz. 

Opt. A4 - North American 240 V; 60 Hz. 

Opt. AS - Switzerland 220 V; 50 Hz. 

See page 619 for description. 



Ordering Information 



For price information: Outside the U.S. contact 

TLA 714 

Portable Color Mainframe. 

Includes: Mouse, Keyboard, Front-panel Cover, 
Accessory Pouch, Panel Rllers for Empty Slots, 

Printer Adapter, Software, Manuals, Certificate of 
Traceable Calibration, and One-year Warranty 
(return to Tektronix). 

TLA 720 

Benchtop Color Mainframe. 

Includes: Mouse, Keyboard, Panel Fillers for Empty 
Slots, Printer Adapter, P6041 External Signal Cables 
(2); Software, Manuals, max DRAM/max replaceable 
HD, Certificate of Traceable Calibration, and One- 
year Warranty (return to Tektronix). Display is not 
included - order Opt. IM or Opt. 2M or use any 
SVGA monitor. 

TLA 714/720 OPTIONS 

Opt. IS - 128 MB DRAM/max replaceable HDD 

(TLA 714 only). 



TLA 714 /TLA 720 SERVICE OPTIONS 
Opt. Dl - Add calibration test data report. 

Opt. IN - Product installation service (on-site config- 
uration and user familiarization; excluding network 
integration). 



the price list in the hack of this catalog. 

Opt. C3 - Three years of calibration service 
(includes initial calibration and two annual 
calibrations). 

Opt. D3 - Provides test data for each calibration 
(must be ordered with Opt. C3). 

Opt. R3 - Extends depot repair warranty service 
period to three years. 

Opt. SI - Uplifts standard one-year warranty 
service of mainframe and Installed modules to 
on-site service. 

Opt. S3 - Uplifts Opt. C3 and/or R3 of mainframe 
and installed modules to on-site service (must be 
ordered with Opt. C3 and/or R3). 

TLA 704/714 / TLA 711/720 OPTIONAL 
ACCESSORIES 

Logic Analyzer Cart - LA Cart. 

TLA 711 Rackmount Kit - Order 020-2197-00. 
TLA 720 Rackmount Kit - Order 020-2221-00. 



Mrww.tektronix.coai/Measureineflit/logk_aiialyzers/ 



LOGIC ANALYZERS 133 




Logic Analyzers 

TLA 700 SERIES 



■k 



Ordering Information (Continued) 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



Customer Wants To: 


Customer's Current 
Mainframe Configuration 


Customer Should Order 


TLA704 Portable and TLA711 Benchtop Mainframe Upgrades 


Use a TLA7Nx/Px LA Module 
in a TLA704/711 mainframe 


TLA704/7II Std. or Opt. IS 
with Vl.((/t.)/2.0 SW 


TLA7UP Opt 01 


Upgrade the TLA704/711 
mainframe to use V3.0 application SW 


TLA704/711 Std. or Opt. IS 
withVI.0/U/2.0SW 


Maximum Performance 
For the customer who wants the latest 
upgrade for maximum peformance from 
their TLA 700 and/or may install a 
TLA7Nx/Px LA module at a later date. 
TLA7UP Opt 01 






Maximum Value 

For the customer who only wants V3.0 
application SW, is satisfied with current 
performance of their TLA 700 and has no 
plans to install a TLA7Nx/Px LA 
module at a later date.TLA7UP Opt. 06 






CD-ROM media which requires 
Windows 98 upgrade [TLA7UP Opt 07] 
& CD-ROM drive rTLA7UP Opt 08] 


Increase DRAM to 128MB in 
TLA704/711 mainframe 


TLA704/711 Std. or Opt IS 


TLA7UP Opt 02 


Increase size of fixed HDD in 
TLA704/711 mainframe 


TLA704/711 Std. 


TLA7UP Opt 04 


TLA714 Portable and TLA720 Benchtop Mainframe Upgrades 


Increase DRAM to 128MB In 
TLA714 mainframe 


TLA714 Std. 


TLA7UPOpt.03 


Increase size of replaceable HDD to 
MAX in TLA714 mainframe 


TU7t4 Std. 


TLA7UP Opt 04 


Add additional replaceable HDDs 
for TLA714/720 mainframe 


TLA714 Std. or Opt IS 
TLA720 Std. 


TLA7UP Opt 04 


Reconfigure replaceable HDD 


TLA714 Std. or Opt 1 S TLA720 Std. TLA7UP Opt. 04 



for data storage only 
(requires user to install replaceable 
HDD as an internal, fixed HDD) 

In TLA714/720 mainframe 



LOGIC ANALYZER "N & P" MODULE PROBE OPTIONS 

Quantity of probes per option 

TLA7N1 TLA7N2 


TLA7N3 


TLA7N4 


TLA7P2 


TLA7P4 


IP Add P6418 Probes 


2 


4 


6 


8 


4 


8 


2P Add P6434 Probes 




2 


3 


4 


2 


4 


3P Add P6417 Probes 


2 


4 


6 


8 


4 


8 



TLA 704/714 Wheeled Transport Case - Order 
016-1522-00. 

TLA 711/720 Wheeled Transport Case > Order 
016-1651-00. 

17 in. Monitor Transport Case - Order 016-1653-00. 
21 in. Monitor Transport Case - Order 016-1652-00. 
15 in. Color TFT LCD Monitor (1024 x 768) - 

Order 119-5971-00. 

83 Key Notebook Keyboard, PS/2 Compatible - 

Order 118-9402-00. 

TLA 7QS - TLA 700 Series Training Package. 

(TLA 700 configuration required: 102 Ch LA Module 
plus 2 Ch DSO Module plus V 3.0 Application S/W). 
Opt. A1 - Universal Euro. 

Opt. A2 - United Kingdom. 

Opt. A6 - Japan. 

TLA 7QS Technical Reference Support Kit - 

Order 020-2211-02. 

TLA 700 SERIES SERVICE DOCUMENTS AND 
TEST FIXTURES 

TLA 704 Service Manual - Order 070-9777-00. 

TLA 714 Service Manual - Order 070-0267-00. 

TLA 711 Chassis Service Manual - Order 

070- 9773-00. 

TLA 720 Chassis Service Manual - Order 

071- 0268-00. 

TLA 711 Controller Service Manual - Order 

070- 9778-00. 

TLA 720 Controller Service Manual - Order 

071- 0269-00. 

TLA 700 Series Performance Verification and 
Adjustment Technical Reference Manual > 

Requires Logic Analyzer Module Adjustment Fixture 
Order 070-9776-00. 

TLA 7Lx/7Mx/7Nx/7Px Logic Analyzer Module 
Adjustment Fixture (includes AC adapter; 
requires local power cord) - Order 671-3599-00. 
TLA 7Lx/7Mx Logic Analyzer Modules Service 
Manual - Order 070-9779-00. 

TLA 7Nx/7Px Logic Analyzer Modules Service 
Manual - Order 071-0266-00. 

TLA 7Dx/7Ex DSO Modules Service Manual - 
Order 070-9780-00. 

TLA 700 SERIES MAINFRAME FIELD 
UPGRADE KIT 

TLA7UP - See table above for ordering information. 
Kit is customer installable. 

Opt. 01 - TLA 704/711 Support for TLA7Nx/Px (con- 
sists of opt's 02, 04, 05, 06, 07, 08 in one package). 
Opt. 02 - TLA 704/711 128 MB DRAM. 

(2 64 MB SIMMs) 

Opt. 03 - TLA 714 128 MB DRAM. 

(2 64 MB SODlMMs) 

Opt. 04 - TLA 704/711 TLA 714/720 MAX Hard Disk. 
Opt. 05 - TLA 704 Cooling Shutter Upgrade Kit. 
Opt. 06 - TLA 700 Series Applications SW. 

Opt. 07 - Windows 98 OS. 

Opt. 08 - TLA 704/711 External PCMCIA 
CD-ROM Drive. 

Opt. IN - On-Site Installation Service. 



Opt. IF - Tektronix Installation Service. 

LOGIC ANALYZER MODULES 
Includes: Probe retainer bracket, probe manual. 
Installation Manual, Certificate of Traceable 
Calibration, One-year Warranty (return to Tektronix), 
and your choice of probes. 

TLA 7N1 - 34-CH Logic Analyzer module, 2 GHz 
timing, 100 MHz state, 64 K depth (must select one 
probe option below). Can PowerFlex up to 4 M 
depth and/or 200 MHz state. 

TLA 7N2 - 68-CH Logic Analyzer module, 2 GHz 
timing, 100 MHz state, 64 K depth (must select one 
probe option below). Can PowerFlex up to 4 M 
depth and/or 200 MHz state. 

TLA 7N3 - 102-CH Logic Analyzer module, 2 GHz 



timing, 100 MHz state, 64 K depth (must select one 
probe option below). Can PowerFlex up to 4 M 
depth and/or 200 MHz state. 

TLA 7N4 - 136-CH Logic Analyzer module, 2 GHz 
timing, 100 MHz state, 64 K depth (must select one 
probe option below). Can PowerFlex up to 4 M 
depth and/or 200 MHz state. 

TLA 7P2 - 68-CH Logic Analyzer module, 2 GHz 
timing, 100 MHz state, 16 M depth (must select one 
probe option below). PowerFlex to 200 MHz state. 
TLA 7P4 - 136-CH Logic Analyzer module, 2 GHz 
timing, 100 MHz state, 16 M depth (must select one 
probe option below). PowerFlex to 200 MHz state. 



134 LOGIC ANALYZERS 



www.tektronix.com/Measurement/logic.aiialyzers/ 




Logic Analyzers 

TLA 700 SERIES 



Ordering Information (Continued) 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 

Opt. IP - Add P6418 probes (each includes two 
8-CH leadsets, one 1-CH leadset, 20 SMT KlipChip"* 

Grabber tips). 

Opt. 2P - Add P6434 probe(s). 

Opt. 3P - Add P6417 probes (each includes two 
8-CH leadsets, one 1-CH leadset, 20 SMT KlipChip’" 

Grabber tips). 

LOGIC ANALYZER ''N" MODULE OPTIONS 

(Base configuration is 64 K (g 100 MHz) 

IS - Increase memory to 256 K. 

2S - Increase memory to 1 M. 

3S - Increase memory to 4 M. 

4S - Increase speed to 200 MHz state. 

5S - Increase memory and speed to 256 K - 
200 MHz state. 

6S - Increase memory and speed to 1 M - 
200 MHz state. 

7S - Increase memory and speed to 4 M - 
200 MHz state. 

LOGIC ANALYZER "P" MODULE OPTIONS 

(Base configuration is 100 MHz) 

IS - Increase speed to 200 MHz state. 

TLA 700 SERIES MODULE MEMORY/STATE 
SPEED FIELD UPGRADE KITS 

For details and pricing on upgrading the speed or 
memory depth of your current TLA7Lx/7Mx/7Nx/7Px 
series modules please contanct your local Tektronix 
Account Manager. 

For TLA 7Lx/7Mx LA Modules - Order TLA7F2. 

For TLA 7N1 LA Module - Order TLAFll. 

For TLA 7N2 LA Module - Order TLAF12. 

For TLA 7N3 LA Module - Order TLAF13. 

For TLA 7N4 LA Module - Order TLAF14. 

For TLA 7P2 LA Module - Order TLAF16. 

For TLA 7P4 LA Module > Order TLAF18. 

LOGIC ANALYZER MODULE SERVICE OPTIONS 
Opt. D1 - Add calibration test data report. 

Opt. IN - Product installation service (on-site config- 
uration and user familiarization, excluding network 
integration). 

Opt. C3 - Three years of calibration service (includes 
initial certification and two annual calibrations). 

Opt. D3 - Provide test data for each calibration 
(must be ordered with Opt. C3). 

Opt. R3 - Extends depot repair warranty service 
period to three years. 

LOGIC ANALYZER MODULE ACCESSORIES 
17- CH Probe and Accessories for TLA 7Lx/ 

TLA 7Mx, TLA 7Nx/TLA 7Px Logic Analyzer 
Modules - Order P6417. 

17-CH Probe and Accessories for TLA 7Lx/ 

TLA 7Mx, TLA 7Nx/TLA 7Px Logic Analyzer 
Modules - Order P6418. 

P6417 to HP/3M Type 3592, 2x10, 0.1 in. 

Adapter - 

Order UPIK3M (5 ea.). 

Order 671-2508-00 (1 ea.). 



www.tektronix.com/Measurement/logic.anaiyiers/ 




P6417 




P6418 



34-CH Probe Interface Kit w/ Barrel 
Connectors - Order 020-2199-00. 

34-CH Probe Interface Kit w/ mini-PV 
Connectors - Order 020-3000-00. 



34-CH Probe and Accessories for TLA 7Lx/TLA 
7Mx, TLA TNx/TLA 7Px Logic Analyzer 
Modules - Order P6434. 

34-CH Low-Profile Leadset for P6434 - Order 
P6434 Option 01. 



LOGIC ANALYZERS 135 




Logic Analyzers 

TLA 700 SERIES 



Part Number 


Description 


010-6417-00 


17-ch Probe. 


N/A 


2 each - 8-ch podlet 
holders (Installed). 


N/A 


1 Set of 17 podlet color coding 

bands (installed) 


334-9239-00 


1 Sheet of probe labels 
(not installed). 


196-3459-00 


2 each - 8-ch leadsets 
(barrel connectors) and 
1 each - 1-ch leadset 
(barrel connectors). 


206-0364-00 


20 each - SMT KlipChips. 


013-0280-00 


(optional) One to 
Two Adapter. 


SMK4 


(optional) Micro KlipChip 
Adapter, 4 each. 


071-0567-00 


P6417/P6418 
Instruction Manual 


010-6418-00 


17-ch Probe. 


334-9979-00 


1 Sheet of probe labels 
(not installed). 


196-3459-00 


2 each - 8-ch leadsets 
(barrel connectors) and 
1 each - 1-ch leadset 
(barrel connectors). 


206-0364-00 


20 each - SMT KlipChips. 


013-0280-00 


(optional) One to 
Two Adapter. 


SMK4 


(optional) Micro KlipChip 
Adapter, 4 each 


071-0567-00 


P6417/P6418 
Instruction Manual 



DSO MODULES 

Includes: Probes, Manual, Certificate of Traceable 
Calibration, and One-year Warranty (return to 
Tektronix). 

TLA 7DI - 2-CH DSO module, 500 MHz bandwidth, 

2.5 GS/s sample rate, 15 K depth (includes two 
P6243 1.0 GHz active FET probes, probe calibration 
adapter, and manual). 

TLA 7D2 - 4-CH DSO module, 500 MHz bandwidth, 

2.5 GS/s sample rate, 15 K depth (includes four 
P6243 1.0 GHz active FET probes, probe calibration 
adapter, and manual). 

TLA 7E1 - 2-CH DSO module, 1 GHz bandwidth, 5 
GS/s sample rate, 15 K depth (Includes two P6245 

1.5 GHz active FET probes, probe calibration adapter, 
and manual). 

TLA 7E2 - 4-channel DSO module, 1 GHz band- 
width, 5 GS/s sample rate, 15 K depth (includes four 
P6245 1.5 GHz active FET probes, probe calibration 
adapter, and manual). 







214 ^ 227-00 



laatfcM 

Part Number 


Description 


010-6434-00 


34-ch probe. 


N/A 


1 Sheet of probe labels 

(not installed). 


105-1088-00 


1 Latch housing assembly. 
Edge-mount. 


105-1089-00 


1 Latch housing assembly, 
Vertical. 


070-9793-02 


Instruction Manual. 


131-6134-01 


(optional) 1 each - AMP Mictor 
Connector, Surface-Mount. 


020-2228-00 


(optional) 21 each - AMP 
Mictor Connector, Surface-Mount. 


010-0612-00 


(optional) Low-Profile 
Leadset for P6434 



DSO MODULE SERVICE OPTIONS 
Opt. D1 - Add calibration test data report. 

Opt. IN - Product Installation service (on-site config- 
uration and user familiarization, excluding network 
integration). 

Opt. C3 - Three years of calibration service 
(includes Initial certification and two annual 
calibrations). 

Opt. D3 - Provide test data for each calibration 
(must be ordered with Opt. G). 

Opt. R3 - Extends depot repair warranty service 
period to three years. 




Part Number 


Description 


003-1383-00 


Compensation Box and 
Cover Removal Tool. 


003-1433-00 


Adjustment Tool. 


016-1315-00 


2 each - 5 colors of 
Cable Markers. 


131-5638-10 


10 each - Solderable 
Probe Tips. 


131-5777-00 


100 mil Square-Pin 
Ground Adapter. 


196-3410-00 


Ground lead set includes: 


N/A 


2 each - 1 in., 3 in., 

6 in. Ground Leads 
w/ Square Pin Receptacle; 


N/A 


2 each - Y Lead Adapters. 


196-3439-00 


1 in. Ground Lead. 


206-0364-00 


SMT KlipChip™, 
1 each 


214-4227-00 


Right Angle Square-Pin 
Adapter. 


SF501 


SureFoot Probe Tip Adapter, 
pkg. of 12, Yellow, 50 mil Pitch. 


SF502 


SureFoot Probe Tip Adapter, 
pkg. of 12, Blue, 25 mil/ 
0.65 mm Pitch. 


SF503 


SureFoot Probe Tip Adapter, 
pkg. of 12, Red, 0.5 mm Pitch. 


SMC50 


SMT KlipChip, 20 each. 


SMK4 


Micro KlipChip Adapter, 
4 each. 


070-9408-00 


P6243 Instruction Manual. 


070-8995-01 


P6245 Instruction Manual. 



DSO MODULE ACCESSORIES 

P6243 - 1.0 GHz Active FET Probe and accessories, 

length 1.5 m. 

P6245 - 1.5 GHz Active FET Probe and accessories, 
length 1.5 m. 

P6246 - 400 MHz, Differential Probe, 30 dB CMRR. 
P6247 - 1.0 GHz, Differential Probe, 30 dB CMRR. 
P6248 - 1.7 GHz, Differential Probe, 30 dB CMRR. 
P6249 - 4.0 GHz, Active FET Probe and accessories, 
length 1.3 m. 

TCP202 - Current probe, DC-15A, DC-50 MHz. 



For your local Tektronix representative see the list In 
the oack of this catalog or outside the U.S. call: 
1-503-627-1916. inside the U.S. call: 1-800-426-2200. 



C€ 



136 LOGIC ANALYZERS 



www.tektronix.coin/Measarenent/logic_aiialyzers/ 



Channels 

Device Package Usage Order These Items: Required 



AMD 

Aml88EA 


N/A 


S/W only 


Contact Cost. Supt. Cntr.*^ 


68 


Aml88EB 


N/A 


S/W only 


Contact Cost. SupL Cntr.*^ 


68 


Aml86EA 


N/A 


S/W only 


Contact Cost. Supt. Cntr.*^ 


68 


Aml86EB 


N/A 


S/W only 


Contact Cusl Supt. Cntr.*^ 


68 


Am80386DX 


QFP-132 


Socketed 


TMS104 + Opt 02 


102 


Am80486DX 


PGA-168 


Socketed 


TMSl07 + OpL 01 


102 


Am80486DX2 


PGA-168 


Socketed 


TMS107 + Opt 01 


102 


Am80486SX 


PCA-168 


Socketed 


TMS107 + OpL 01 


102 


AMD K6-2 
lOOMHz 


PCA-321 


Socketed 


TMS109A + Opt 01 


136 


Am80486SX2 


PGA-168 


Socketed 


IMS 107 + Opt 01 


102 


29030 


PGA-145 


Socketed 


TMS480 + Opt 01 


102 


29035 


PGA- 145 


Socketed 


TMS480 + Opt 01 


102 


29040 


PGA-145 


Socketed 


TMS480 + Opt 01 


102 


ARM 

TMS470 -Tl 


N/A 


S/W only 


Contact Cust. Supt. Cntr.*^ 


102 


ARM7TDMI 
Development Board 


S/W only 


Contact Cust. Supt Cntr.*^ 


102 


AMBA-ASB 


N/A 


S/W only 


Contact Dragonfly Software*^ 


102 


SA-110 


TQFP-144 


Soldered 


Contact NewWave PDG*’ 


102 


ARM7T 


N/A 


S/W only 


Contact Dragonfly*^ 


102 


SA-1100 


N/A 


S/W only 


Contact New Wave PDG*’ 


102 


CYRIX 

6x86 


PGA-296 


Socketed 


TMS109A + Opt 01 


136 


6x86 lOOMHz 


PGA-296 


Socketed 


TMS109A + Opt 01 


136 


DALLAS SEMICONDUCTOR 

80C510 N/A S/W only 


Contact Cust. Supt Cntr.*^ 


68 


80C320 


N/A 


S/W only 


Contact Cust. Supt Cntr.*^ 


68 


80C323 


N/A 


S/W only 


Contact Cust. Supt Cntr.*® 


68 


83C520 


N/A 


S/W only 


Contact Cust. Supt Cntr.*® 


68 


87C520 


N/A 


S/W only 


Contact Cust. Supt Cntr.*® 


68 


87C530 


N/A 


S/W only 


Contact Cust. Supt Cntr.*^ 


68 


DIGITAL EQUIPMENT CORP. 

Alpha AXP PGA-431 Socketed 

21064 


TEK-AIPHA-PCA17-HDW timing 
only, Contact Emulation Tech*^ 




Strong ARM 
SA-110 


TQFP-144 


Soldered 


Contact New Wave PDG*’ 


102 


HITACHI 

SH-3 "7708" 


QFP-144 


Soldered 


TMS440 + Opt 01 


102 


64180 


N/A 


S/W only 


Contact Cust. Supt Cntr.*^ 


68 


IBM 

PPC403GA 


N/A 


S/W only 


TMS531 


102 


PPC403GC 


N/A 


S/W only 


TMS531 


102 


PPC403GCX 


N/A 


S/W only 


TMS531 


102 


PPC601 


QFP-304 


Soldered 


TMS540 + Opt 11 + 
Opt 22 + Opt 12 


136 


PPC601 


N/A 


S/W only 


TMS540 


136 


PPC603 


QFP-240 


Soldered 


TMS540 + Opt 11 + 
Opt 22 + Opt 14 


136 


PPC603 


N/A 


S/W only 


TMS540 


136 


PPC603e 


N/A 


S/W only 


TMS540 


136 



Channels 



Device 


Package 


Usage 


Order These Items: 


Required 


IBM (CONTINUED) 

PPC604 N/A 


S/W only 


TMS540 


136 


PPC604e 


N/A 


S/W only 


TMS540 


136 


PPC740 


N/A 


S/W only 


TMS541;for BGA Probe, 
LA-BGA-740-S-B-01, Contact 
Ironwood Electronics*^ 


136 


PPC750 


N/A 


S/W only 


TMS541;for BGA Probe, 
LA-BGA-750-S-B-01, Contact 
Ironwood Electronics*^ 


136 


INTEL 

8051/31 


8031 


DIP-40 


Socketed 


TMS140 + Opt 01 


68 


8031 


DIP-40 


Soldered 


TMS140 + Opt 01 + 015-0646-00 


68 


8031 


PLCC-44 


Socketed 


TMS140-HUPIK44 


68 


8031 


PLCC-44 


Soldered 


TMS140 + Opt 01 + 
(AC-DIP-PCC-8031/51, 
Contact Emulation Tech)*^ 


68 


8032 


DIP-40 


Socketed 


TMS140 + Opt 01 


68 


8032 


DIP-40 


Soldered 


TMS140 + Opt 01 + 015-0646-00 


68 


8032 


PLCC-44 


Socketed 


TMS140 + UPIK44 


68 


8032 


PLCC-44 


Soldered 


TMS140 + Opt 01 + 
(AC-DIP-PCC-8031/51, C 
ontact Emulation Tech)** 


68 


8051 


DIP-40 


Socketed 


TMS140 + Opt 01 


68 


8051 


DIP-40 


Soldered 


TMS140 + Opt 01 + 015-0646-00 


68 


8051 


PLCC-44 


Socketed 


TMS140 + UPIK44 


68 


8051 


PLCC-44 


Soldered 


TMS140 + Opt 01 + 
(AC-DIP-PCC-8031/51, 
Contact Emulation Tech)** 


68 


8052 


DIP-40 


Socketed 


TMS140 + Opt 01 


68 


8052 


DIP-40 


Soldered 


TMS140 + Opt 01 + 015-0646-00 


68 


8052 


PLCC-44 


Socketed 


TMS140 + UPIK44 


68 



8052 PLCC-44 Soldered TMS140 + Opt. 01 + 

(AC-DIP-PCC-8031/51, 

Contact Emulation T e ch)* ^ 68 



80C152 DIP-48 Socketed TMS140 + 013-0266-00 68 

80C152 DIP-48 Soldered TMS140 + 013-0266-00 68 



80C152 


PLCC-68 


Socketed 


TMS140 + UPIK68 


68 


80C152 


PLCC-68 


Soldered 


TMS140 + 013-0250-00 


68 


80C251 


PLCC-44 


Socketed 


TMS143 + Opt 01 


68 


MCS251 


PLCC-44 


Socketed 


TMS143 Opt 01 


68 


80C452 


PLCC-68 


Socketed 


TMS140 + UPIK68 


68 


80C452 


PLCC-68 


Soldered 


TMS140 + 013-0250-00 


68 


80515 


PLCC-68 


Socketed 


TMS140 + UPIK68 


68 


80515 


PLCC-68 


Soldered 


TMS140 + 013-0250-00 


68 


80532 


PLCC-68 


Socketed 


TMS140 + UPIK68 


68 


80532 


PLCC-68 


Soldered 


TMS140 + 013-0250-00 


68 


80535 


PLCC-68 


Socketed 


TMS140 + UPIK68 


68 


80535 


PLCC-68 


Soldered 


TMS140 + 013-0250-00 


68 


83C152 


DIP-48 


Socketed 


TMS140 + 013-0266-00 


68 


83C152 


DIP-48 


Soldered 


TMS140 + 013-0266-00 


68 


83C152 


PLCC-68 


Socketed 


TMS140 + UPIK68 


68 


83C152 


PLCC-68 


Soldered 


TMS140 + 013-0250-00 


68 


83C452 


PLCC-68 


Socketed 


TMS140 + UPIK68 


68 


83C452 


PLCC-68 


Soldered 


TMS140 + 013-0250-00 


68 



www.tektronix.com/Measurement/logic_analyzers/ 



LOGIC ANALYZERS 137 



Rpvirp 


Package 


Usage 


Order These Items: 


Channels 

Required 


Device 


Package 


Usage 


Channels 

Order These Items: Required 


INTEL (CONTINUED) 

PI fC-84 


Socketed 


TMS140 + UPIK84 


68 


INTEL (CONTINUED) 

87C196KC PGA-68 


Socketed 


IMS 141 + Opt. 01 


68 


83C537 


PLCC-84 


Soldered 


TMS140 + 013-0263-00 


68 


87C196KC 


PLCC-68 


Socketed 


TMS141 + Opt 02 


68 


8096/196/296 










87C196KC 


PLCC-68 


Soldered 


TMS141 + Opt. 01 + 
013-0250-00 + 103-0311-00 




anoARM 


PLCC-68 


Socketpd 


TMS141 + Opt 02 


68 








68 


8096BH 


PLCC-68 


Soldered 


TMS141 + Opt 01 + 
013-0250-00+ 103-0311-00 




87C196KD 


PGA-68 


Socketed 


TMS141 + Opt 01 


68 


68 


87C196KD 


PLCC-68 


Socketed 


TMS141 Opt 02 


68 


8096BH 


PGA-68 

PLCC-68 


Socketed 


TMS141 + Opt. 01 
TMS141 + Opt 02 


68 

68 


87C196KD 


PLCC-68 


Soldered 


TMS141 * Opt. 01 + 
013-0250-00 103-0311-00 


68 


ojybbn 

8396BH 


PLCC-68 


Soldered 


TMS141 + Opt 01 + 
013-0250-00 + 103-0311-00 


68 


80C196NP 

80C196NT 


QFP-100 

PLCC-68 


Soldered _ 
Socketed 


TMS142 + Opt.01 +Opt22 
TMS142 + Opt 02 -f Opt 22 


102 

102 


8396BH 


PGA-68 


Socketed 


TMS141 + Opt 01 


68 


80C296 


QFMOO 


Soldered 


TMS144 + Optll 


68 


8097BH 


PLCC-68 


Socketed 


TMS141 + Opt 02 


68 


MCS296 


QFP-100 


Soldered 


TMSl44 + Optll 


68 


8097BH 


PLCC-68 


Soldered 


TMS141 + Opt 01 + 
013-0250-00+ 103-0311-00 




8085 


N/A 


5/Wonly 


Contact Cust. Supt. Cntr.*^ 


68 


68 


80C85 


N/A 


S/W only 


Contact Cust Supt Cntr.*^ 


68 


8097BH 


PGA-68 


Socketed 


TMS141 + Opt 01 


68 


X86 










8097JF 


PLCC-68 


Socketed 


TMS141 + Opt 02 


68 


8086 


DIP-40 


Socketed 


TMS101 Opt 01 


102 


8097JF 


PLCC-68 


Soldered 


TMS141 + Opt 01 + 




8086 


DIP-40 


Soldered 


TMS101 + Opt 01 + 015-0646-00 


102 




013-0250-00 + 103-0311-00 


68 


8086 


PLCC-44 


Soldered 


TMSIOI + Opt 01 + 




8097JF 


PGA-68 


Socketed 


TMSI41 + OpL 01 


68 






(AC-DIP-PLCC-8086/88, 


102 


8397BH 


PLCC-68 


Socketed 


IMS 141 + Opt 02 


68 








Contact Emulation Tech)** 


8397BH 


PLCC-68 


Soldered 


TMS141 + Opt 01 + 
013-0250-00 + 103-0311-00 




80C86 


DIP-40 


Socketed 


TMSIOI+OptOI 


102 


68 


80C86 


DIP-40 


Soldered 


TMSIOI + Opt 01 + 015-0646-00 


102 


8397BH 


PGA-68 


Socketed 


TMS141 + Opl 01 


68 


80C86 


PLCC-44 


Soldered 


TMSIOI + Opt 01 + 




8397JF 


PLCC-68 


Socketed 


TMS141 + Opt 02 


68 








(AC-DlP-PLCC-8086/88, 
Contact Emulation Tech)** 


102 


8397JF 


PLCC-68 


Soldered 


TMS141 + Opt 01 + 
013-0250-00 + 103-0311-00 


68 


8088 


DIP-40 


Socketed 


TMSIOI + Opt 01 


102 


8397 JF 


PGA-68 


Socketed 


TMS141 + Opt 01 


68 


8088 


DIP-40 


Soldered 


TMSIOI + Opt 01 + 015-0646-00 


102 


8797BH 


PLCC-68 


Socketed 


TMS141 +OpL02 


68 


8088 


PLCC-44 


Soldered 


TMSIOI + Opt 01 + 
(AC-DIP-PLCC-8086/88, 
Contact Emulation Tech)** 




8797BH 


PLCC-68 


Soldered 


TMS141 + Opt 01 + 
013-0250-00 + 103-0311-00 


68 








102 


8797BH 


PGA-68 


Socketed 


TMS141 + OpL 01 


68 


80C88 

80C88 

80C88 


DIP-40 

DIP-40 


Socketed 

Soldered 


TMSIOI + Opt 01 
TMSIOI + Opt 01 + 015-0646-00 


102 

102 


8797JF 

8797JF 


PLCC-68 

PLCC-68 


Socketed 

Soldered 


TMS141 + Opl 02 
TMS141 + Opt 01 + 
013-0250-00+ 103-0311-00 


68 

68 


PLCC-44 


Soldered 


TMSIOI + Opt 01 + 
(AC-DIP-PLCC-8086/88, 
Contact Emulation Tech)** 


102 


8797JF 


PGA-68 


Socketed 


TMS141 + Opt 01 


68 


80186 


PGA-68 


Socketed 


TMS102 + Opt 01 


102 


80C196KB 


PGA-68 


Socketed 


TMS141 + Opl 01 


68 


omfiA 


PLCC-68 


Socketed 


TMS102 + Opt 02 


102 


80C 196KB 


PLCC-68 


Socketed 


TMS141 +Opl02 


68 


oUlOO 

80186 


PLCC-68 


Soldered 


TMS102 + Opt 01 + 
013-0250-00 + 103-0311-00 




80C196KB 


PLCC-68 


Soldered 


TMS141 + Opt 01 + 


68 


102 








013-0250-00 + 103-0311-00 


80186 


1 rr C.Q 




TMS102 + Oot 01 + 




80C196KB16 


PGA-68 


Socketed 


TMS141 + Opt 01 


68 


LLL-Oo 


DOLKtjlcU 


136-1023-00 + 136-0921-00 + 




80C196KB16 


PLCC-68 


Socketed 


TMS141 + Opt 02 


68 








103-0294-00 


102 


80C196KB16 


PLCC-68 


Soldered 


TMS141 + Opt 01 + 
013-0250-00 + 103-0311-00 


68 


80186 


QFP-80 


Soldered 


TMS102 + Opt 01 + 
(AC-PGAl -QF08-80186/88-NTP-A, 




80C196KC 


PGA-68 


Socketed 


TMS141 + Opt 01 


68 








Contact Emulation Tech)** 


102 


80C196KC 


PLCC-68 


Socketed 


TMS141 + Opl 02 


68 


80C186 


PGA-68 


Socketed 


TMS102 Opt 01 


102 


80C196KC 


PLCC-68 


Soldered 


TMS141 + Opt. 01 + 
013-0250-00 + 103-0311-00 




80C186 


PLCC-68 


Socketed 


TMS102 + Opt02 


102 


68 


80C186 


PLCC-68 


Soldered 


TMS102 + Opt 01 + 




80C196KD 


PGA-68 


Socketed 


TMS141 + Opt 01 


68 








013-0250-00 + 103-0311-00 


102 


80C196KD 


PLCC-68 


Socketed 


TMS141 + Opl 02 


68 


80C186 


LCC-68 


Socketed 


TMS102 + Opt 01 + 




80C196KD 


PLCC-68 


Soldered 


TMS141 + Opt 01 + 
013-0250-00 + 103-0311-00 


68 








136-1023-00 + 136-0921-00 + 
103-0294-00 


102 


87C196KB16 


PGA-68 


Socketed 


TMS141 + Opt 01 


68 


80C186 


QFP-80 


Soldered 


TMS102 + Opt 01 + 
(AC-PGAl -QF08-80186/88-NTP-A, 
Contact Emulation Tech)** 




87C196KB16 


PLCC-68 


Socketed 


TMS141 + Opt 02 


68 








102 


87C196KB16 


PLCC-68 


Soldered 


TMS141 + Opt 01 + 
013-0250-00+ 103-0311-00 


68 


80C186XL 


PGA-68 


Socketed 


TMS102 + Opt 01 


102 



















138 LOGIC ANALYZERS 



www.tefctronix.coiii/MeasurMieaVlo(k_aRalyzers/ 



Device 


Package 


Usage 


Channels 

Order These Items: Required 


INTEL (CONTINUED) 

80C186XL PLCC-68 Socketed 


TMS102 + Opt 02 102 


80C186XL 


PLCC-68 


Soldered 


TMS102 + Opt 01 + 
013-0250-00+ 103-0311-00 102 


80C186XL 


LCC-68 


Socketed 


TMS102 + Opt 01 + 136-1023-00 + 
136-0921 -00 + 103-0294-00 102 


80C186XL 


QFP-80 


Soldered 


TMS102 + Opt 01 + 

(AC-PGA1 -QF08-80186/88-NTP-A, 
Contact Emulation Tech)*® 102 


80C186EA 


PGA-68 


Socketed 


Contact Cust Supt Cntr *® 102 


80C186EA 


PLCC-68 


Socketed 


Contact Cust. SupL Cntr.*^ 102 


80C186EA 


PLCC-68 


Soldered 


Contact Cust. SupL Cntr.*^ 102 


80C186EA 


LCC-68 


Socketed 


Contact Cust. Supt Cntr.*^ 102 


80C186EA 


QFP-80 


Soldered 


Contact Cust. Supt Cntr.*® 102 


80C186EB 


PLCC-84 


Soldered 


Contact Cust Supt Cntr.*® 102 


80186EB 


N/A 


S/Wonly 


Contact Cust. Supt Cntr.*9 68 


80186EC 


N/A 


S/Wonly 


Contact Cust. Supt Cntr.*^ 68 


80188 


PGA-68 


Socketed 


TMS102 + Opt01 102 


80188 


PLCC-68 


Socketed 


TMS102 + Opt 02 102 


80188 


PLCC-68 


Soldered 


TMS102 + Opt 01 + 013-0250-00 + 

103-0311-00 102 


80188 


LCC-68 


Socketed 


TMS102 + Opt 01 + 136-1023-00 + 
136-0921 -00 + 103-0294-00 102 


80188 


QFP-80 


Soldered 


TMS102 + Opt 01 + 

(AC-PGAl -QF08-80186/88-NTP-A, 
Contact Emulation Tech)*® 102 


80188 


PGA-68 


Socketed 


TMS102 + Opt01 102 


80C188 


PGA-68 


Socketed 


TMSl02 + OpL01 102 


80C188 


PLCC-68 


Socketed 


TMS102 + Opt 02 102 


80C188 


PLCC-68 


Soldered 


TMS102 + Opt 01 + 013-0250-00 + 

103-0311-00 102 


80C188 


LCC-68 


Socketed 


TMS102 + Opt 01 + 136-1023-00 + 
136-0921 -00 + 103-0294-00 102 


80C188 


QFP-80 


Soldered 


TMS102 + Opt 01 + 

(AC-PGAl -QF08-80186/88-NTP-A, 
Contact Emulation Tech)*® 102 


80C188XL 


PGA-68 


Socketed 


TMS102 + Opt 01 102 


80C188XL 


PLCC-68 


Socketed 


TMSl02 + OpL02 102 


80C188XL 


PLCC-68 


Soldered 


TMS102 + Opt 01 + 

013-0250-00 + 103-031 1-00 102 


80C188XL 


LCC-68 


Socketed 


TMS102 + Opt 01 + 136-1023-00 + 
136-0921-00 + 103-0294-00 102 


80C188XL 


QFP-80 


Soldered 


TMS102 + Opt 01 + 

(AC-PGAl -QF08-80186/88-NTP-A, 
Contact Emulation Tech)*® 102 


80C188EA 


PGA-68 


Socketed 


TMS102 + Opt01 102 


80C188EA 


PLCC-68 


Socketed 


TMS102 + Opt02 102 


80C188EA 


PLCC-68 


Soldered 


TMS102 + Opt 01 + 

0T3-0250-O0 + 103-031 1-00 102 


80C188EA 


LCC-68 


Socketed 


TMS102 + Opt 01 + 136-1023-00 + 
136-0921-00+ 103-0294-00 102 


80C188EA 


QFP-80 


Soldered 


TMS102 + Opt 01 + 

(AC-PGAl -QF08-80186/88-NTP-A, 
Contact Emulation Tech)*® 102 


80C188EB 


PLCC-84 


Soldered 


TMS102 + Opt 01 + 

(AC-PGAl -PCC5-80186EB, 

Contact Emulation Tech)*® 68 



Channels 

Device Package Usage Order These Items: Required 



INTEL (CONTINUED) 



80188EB 


N/A 


S/W only 


Contact Cust. Supt. Cntr.*^ 


68 


80188EC 


N/A 


S/W only 


Contact Cust. Supt. Cntr.*® 


68 


80286 


PGA-68 


Socketed 


TMS103 + Opt 01 


68 


80286 


PLCC-68 


Socketed 


TMS103 + Opt 02 


68 


80286 


PLCC-68 


Soldered 


TMS103 + Opt 01 + 
013-0250-00+ 103-0311-00 


68 


80286 


LCC-68 


Socketed 


TMS103 + Opt 01 + 136-1023-00 + 










136-0921-00 + 103-0294-00 


68 


80376 


PQFP-100 


Soldered 


TMS105 + Opt 01 


68 


80386DX 


PGA-132 


Socketed 


TMS104 + Opt 01 


102 


80386EX 


PQFP-132 


Soldered 


TMS106 + Opt 01 


102 


80386SX 


PQP-100 


Soldered 


TMS105 + Opt 01 


68 


80486SX 


PGA-168 


Socketed 


TMS107 + Opt 01 


102 


80486SX 


QFP-196 


Soldered 


TMS107 + Opt 01 + 
(AC-PGA10-QF15-486SX-NTP, 










Contact Emulation Tech)*® 


102 


80486SX 


QFP-208 


Soldered 


TMS107 + (5770, Contact Pomona)*® 102 


80486DX 


PGA-168 


Socketed 


TMS107 + Opt 01 


102 


80486DX 


QFP-208 


Soldered 


TMS 107 + ( 5770, Contact Pomona)*® 


102 


80486DX-50 


PGA-168 


Socketed 


TMS107 + Opt 01 


102 


(chipset mode) 


PGA-168 


Socketed 


TMS107 + Opt 01 


102 


80486DX2 


PGA-168 


Socketed 


TMS107 + Opt 01 


102 


80486DX2 


QFP-208 


Soldered 


TMS 107 + ( 5770, Contact Pomona)*® 


102 


80486DX4 


PGA-168 


Socketed 


TMS107 + Opt 01 + Opt 11 


102 


80486DX4 


QFP-208 


Soldered 


TM5il07 + ( 5770, Contact Pomona)*® 


102 


80487SX 


PGA-168 


Socketed 


TMS107 + Opt 01 


102 


Pentium 


Pentium-75-150 


PGA-296 


Socketed 


TMS109A + Opt 01 


136 


Pentium-75-150 


PGA-296 


Socketed 


TMS109A + Opt 01 


136 


P54C 


PGA-296 


Socketed 


TMS109A + Opt 01 


136 


P54C 


PGA-296 


Socketed 


TMS109A + Opt 01 


136 


P54CM 


PGA-296 


Socketed 


TMS109A + Opt 01 


136 


P54CM 


PGA-296 


Socketed 


TMS109A + Opt 01 


136 


P54CS 


PGA-296 


Socketed 


TMS109A + Opt 01 


136 


P54CS 


PGA-296 


Socketed 


TMS109A + Opt 01 


136 


P55C 


PGA-296 


Socketed 


TMS109A + Opt 01 


136 


P55C 


PGA-296 


Socketed 


TMS109A + Opt 01 


136 


APIC Bus 


N/A 


GP 


TMS801 + Opt 01 


102 


Pentium Pro 


PGA-387 


Socketed 


TMSllO + Opt 01 


204 


P6 


PGA-387 


Socketed 


TMSilO + Opt 01 


204 


Pentium II 
(66 MHz) 


Slotl 


Socketed 


TMSlll +Opt 01 


204 


Klamath 


Slot 1 


Socketed 


TMSlll + Opt 01 


204 


Pentium II 
(100 MHz) 


Slotl 


Socketed 


TMSll2 + Opt 01 


204 


Deschutes 


Slotl 


Socketed 


TMS112 + Opt01 


204 


Deschutes 


Slot 2 


Socketed 


TMSll2 + OpL02 


204 


Pentium III 


SC242 


Socketed 


TMS113 + TMSS1A 


204 


Celeron 


SC242 


Socketed 


TMS113 + TMSS1A 


204 


Celeron 


PGA370 


Socketed 


TMS113 + TMSPGA 


204 



www.tektronix.com/Measurement/logic_analyiers/ 



LOGIC ANALYZERS 139 





Parkave 


Usage 


Channels 

Order These Items: Required 


Device 


Package 


Usage 


Order These Items: 


Channels 

Required 


INTEL (CONTINUED) 
i960 








MIPS (CONTINUED) 

VR4200 PQFP-208 


Soldered 


CHS310SP Contact 
Crescent Heart Software*^ 


102 


i960CA 

i960CA 


PGA-168 

QFP-196 


Socketed 

Soldered 


TlvlS161 + Opt 01 
TMS161 + Opt. 01 + 
(AC-PGA10-QF15-80960CA-NTP, 
Contact Emulation Tech)** 


lUZ 


VR4300 


PQFP-120 


Soldered 


CHS312SP Contact 
Crescent Heart Software*^ 


102 








102 __ 
102 


VR4310 


N/A 


S/W only 


CHS304 Contact 
Crescent Heart Software*’ 


102 


i960CF 

i960CF 


PGA* 168 
QFP-196 


Socketed 

Soldered 


IIVIjIOI + UPL 01 

TMS161 + Opt. 01 + 
(AC-PGA10-QF15-80960CA-NTP, 
Contact Emulation Tech)** 




R4400PC 


PGA-179 


Socketed 


CHS301SP Contact 
Crescent Heart Software*’ 


102 








102 


R4400MC/SC 


PGA-447 


S/W only 


CHS951 Contact 
Crescent Heart Software*’ 


102 


i960Jx 


PGA-132 


Socketed 


TMS163 + Opt 01 + Opt 22 


102 










i960Jx 


QFP-132 


Soldered 


MS163 + Opt. 01 + Opt 12 + Opt 22 


102 


R4400MC/SC 


PGA-447 


S/W only 


CHS953 Including Lacne bus 
C ontact Crescent Heart Software*’ 204 


i960HA 


PGA-168 


Socketed 


TMS164 + Opt 01 + Opt 22 


102 


R4600 


PGA-179 


Snrkptpd 


CHS301SP Contact 




I960HD 


PGA-168 


Socketed 


TMS164 + Opt 01 + Opt 22 


102 






Crescent Heart Software*’ 


102 


i960HT 


PGA-168 


Socketed 


TMS164 + Opt 01 + Opt 22 


102 


R4600 


MQUAD-208 


Soldered 


CHS305SP-M Contact 




i960RP 


BCA-352 


Elastomer 


TMS165 + Opt 01 or 




Crescent Heart Software*’ 


102 






(for BGA Adapter 
Contact Emulation Tech)** 


102 


R4640 


PQFP-128 


Soldered 


CHS407SP-P Contact 
Crescent Heart Software*’ 


68 


i960RD 


BGA-352 


Elastomer 


TMS165 + Opt 01 or (for BGA 
Adapter Contact Emulation Tech)** 


102 


R4640 


MQUAD-128 


Soldered 


CHS407SP-M Contact 
Crescent Heart Software*’ 


68 


80960CA 


PGA-168 


Socketed 


TMS161 + Opt 01 


102 


R4650 
32-Bit Bus 


MQUAD-208 


Soldered 


CHS413SP Contact 




80960CA 


QFP-196 


Soldered 


TMS161 + Opt 01 + 




Crescent Heart Software*’ 


68 




(AC-PGA10-QFI5-80960CA-NTP, 
Contact Emulation Tech)** 


102 


R4650 
64-Bit Bus 


MQUAD-208 


Soldered 


CHS414SP Contact 64-bit Bus 
Crescent Heart Software*’ 


102 


80960CF 


PGA-168 


Socketed 


TMS161 + Opt 01 


102 


R4700 


PGA-179 


Socketed 


CHS301SP Contact 




80960CF 


QFP-196 


Soldered 


TMS161 + Opt 01 + 






Crescent Heart Software*’ 


102 




(AC-PGA10-QF15-80960CA-NTP, 
Contact Emulation Tech)*® 


102 


R4700 


MQUAD-208 


Soldered 


CHS305SP-M Contact 
Crescent Heart Software*’ 


102 


80960JX 


PCA-152 


Socketed 


TMS163 + Opt. 01 + Opt 22 


102 


R5000 


PGA-223 


S/W only 


CHS131 Contact 




80960JX 


QFP-132 


Sojdered 


TMS163 + Opt 01 + Opt 12 + Opt 22 


1 102 


ext cache 


Crescent Heart Software*’ 


136 


80960HA 


PGA-168 


Socketed 


TMS164 + Opt 01 + Opt 22 


102 


R5000 


PGA-223 


S/W only 


CHS130 Contact 


102 


80960HD 


PGA-168 


Socketed 


TMS164 + Opt 01 + Opt 22 


102: 


no-cache 






Crescent Heart Software*’ 


80960HT 


PGA-168 


Socketed 


TM5164 + Opt 01 + Opt 22 


102 


R5000 


BGA-272 


S/W only 


CHS131 Contact 
Crescent Heart Software*’ 


136 


80960RP 


BGA-352 


Elastomer 


TMS165 + Opt 01 or 
(for BGA Adapter Contact 
Emulation Tech)** 


102 


ext. cache 

R5000 

no-cache 


BGA-272 


S/W only 


CHS 130 Contact 
Crescent Heart Software*’ 


102 


80960RD 


BGA-352 


Elastomer 


TMS165 + Opt 01 or 
(for BGA Adapter 
Contact Emulation Tech)*® 




RM5230/1 


PQUAD-128 


Soldered 


CHS420SP Contact 
Crescent Heart Software*’ 


68 








102 


RM5260/1 


PQUAD-208 


Soldered 


CHS422SP Contact 


102 
















Crescent Heart Software*’ 


MIPS 

(INCL. IDT, QED, LSI Logic 
Semiconductor, Siemens, 
R3051 PGA-88 Socketed 


, NEC, PERFORMANCE 




RM5270/1 

no-cache 


BGA-304 


S/W only 


CHS134 Contact 
Crescent Heart Software*’ 


102 


Toshiba) 

TMS420 + Opt 01 


102 


RM5270/1 

ext-cache 


BGA-304 


S/W only 


CHS135SP Contact 
Crescent Heart Software*’ 


136 


R3051 


PLCC-84 


Socketed 


TMS420 + Opt 02 


102 


VR5432W/0 

MOR's 


PQFP-208 


Soldered 


CHS440SP Contact 




R3052 


PGA-88 


Socketed 


TMS420 + Opt 01 


102 




Crescent Heart Software*’ 


68 


R3052 


PLCC-84 


Socketed 

Socketed 

Socketed 


TMS420 + Opt 02 

T^/lQ/l■5n j. Hnt m 


102 

102 


VR5432 with 
MOR's 


PQFP-208 


Soldered 


CHS442SP Contact 
Crescent Heart Software*’ 


68 


R3081 

R3081 


PGA-88 

PLCC-84 


1 IVI j4ZU + Upi. Ui 

TMS420 + Opt 02 


102 „ 


VR5432, 

OATV kiic 


PQFP-208 


Soldered 


CHS444SP Contact 
Crescent Heart Software*’ 


68 


R4000PC 


PGA-179 


Socketed 


CHS301SP Contact Crescent 
Heart Software*^ 


102 


K43K DUS 

VR5464 W/O 
MDR'c 


BGA-272 


S/W only 


CHS146 Contact 
Crescent Heart Software*’ 


102 


R4000MC/SC 


PGA-447 


S/W only 


CHS951 Contact Crescent 
Heart Software*^ 


102 


IVIUIX 3 

VR5464 with 


Dr/V.-J7T 


c AA/ onlv 


CHS148 Contact 
Crescent Heart Software*’ 


102 


R4000MC/SC 


PGA-447 


S/W only 


CHS953 Including Cache Bus 
Contact Crescent Heart Software*^ 


204 


MUK S 
RM7000 w/o 


DvjM Z/Z 

BGA-304 


3/ WV V/lllj 

S/W only 


CHS151 Contact 
Crescent Heart Software*’ 


136 


VR4200 


PGA-179 


Socketed 


CHS301SP Contact 
Crescent Heart Software*^ 


102 


iViUIn 3 

RM7000 with 


\j\Jr\ Jv/ • 

BGA-304 


S/W only 


CHS153 Contact 
Crescent Heart Software*’ 


136 












MOR's 





140 LOGIC ANALYZERS 



wv¥w.tektronix.coin/IHeanireinent/lo*ic_analyier$/ 



Device 


Package 


Usage 


Order These Items: 


Channels 

Required 


Device 


Package 


Usage 


Order These Items: 


Channels 

Required 


MIPS (CONTINUED) 

RC32364 TQFP-144 Soldered 


CHS403SP 




MOTOROLA (CONTINUED) 

68030 PCA-128 Socketed 


TMS203 + Opt 01 


102 








Contact Crescent Heart Software*^ 68 


68030 


QFP-132 


Soldered 


TMS203 + Opt. 02 


102 


RC64474 


PQUAD-128 


Soldered 


CHS407SP-P Contact 
Crescent Heart Software*^ 


68 


68EC030 


PGA-128 


Socketed 


TMS203 + Opt 01 


102 










PGA-179 


Socketed 


TMS204 + Opt 01 




RC6475, 
32-Bit bus 


PQUAD-208 


Soldered 


CHS413SP Contact 
Crescent Heart Software*^ 




68040 


102 


68 


68040 


TQFP 


Soldered 


TMS204 + Opt 01 + 




RC6475, 
64/32-Blt bus 


PQUAD-S08 


Soldered 


CHS414SP Contact 
Crescent Heart Software*^ 


102 








(For PGA to TQFP adapter, P#8800-0051, 
Contact JM Engineering)*’ 102 






68EC040 


PGA-179 


Socketed 


TMS204 + Opt 01 














102 


MOTOROLA 








68LC040 


PGA-179 


Socketed 


TMS204 + Opt 01 


102 


DSP 










68060 


PGA-223 


Socketed 


TMS205 + Opt 01 


102 


5630X 


N/A 


S/Wonly 


Contact New Wave PDG*’ 


102 


68EC060 


PGA-223 


Socketed 


TMS205 + Opt 01 


102 


680X 










68LC060 


PGA-223 


Socketed 


TMS205 + Opt 01 


102 


6809e 


N/A 


S/W only 


Contact Cust Supt Cntr.*^ 


68 


M-CORE 










68HCXX 










M-Core Eval Board N/A 


S/W only 


Contact Cust. Supt Cntr.*® 


102 


68HC11 


ALL 


S/Wonly 


Contact Cust. Supt. Cntr.*^ 


68 


MMC2001 


N/A 


S/Wonly 


Contact Cust. Supt Cntr.*® 


102 


68HC12 


ALL 


S/W only 


TMS241 


102 


M200 Core 


N/A 


S/Wonly 


Contact Cust. Supt Cntr.*® 


102 


68HC16_ 


ALL 


S/Wonly 


Contact Cust. Supt. Cntr.*^ 


68 


Mcore/ 56652 


N/A 


S/Wonly 


Contact Cust. Supt Cntr.*® 


102 


683XX 










ColdFire 










68302LC 


N/A 


S/Wonly 


Contact Cust. Supt Cntr.*^ 


68 


MCF5202 


PQFP-100 


Socketed 


TMS220 + Opt 11 


102 


68302SC 


N/A 


S/W only 


Contact Cust. Supt Cntr.*^ 


68 


MCF5203 


PQFP-100 


Socketed 


TMS220 + Opt 11 


102 


68302EN 


N/A 


S/W only 


Contact Cust. Supt Cntr."^ 


68 


MCF5204 


TQFP-100 


Socketed 


TMS221 + Opt 11 


102 


68302PM 


N/A 


S/Wonly 


Contact Cust. Supt Cntr.*^ 


68 


MCF5206 


PQFP-160 


Socketed 


TMS222 + Opt 01 


102 


68302QH 


N/A 


S/W only 


Contact Cust. Supt Cntr.*^ 


68 


MCF5206e 


PQFP-160 


Socketed 


TMS222 + Opt 02 


102 


68328 


N/A 


S/W only 


Contact Cust. Supt Cntr.*® 


68 


PPC 










68331 


QFP-132 


Soldered 


TMS260 + Opt 01 


102 


MPC505 


N/A 


S/Wonly 


TMS550 


102 


68332 


QFP-132 


Soldered 


TMS260 + Opt 01 


102 


MPC509 


N/A 


S/W only 


TMS550 


102 


68340 


PGA-145 


Socketed 


TMS260 + Opt 02 


102 


MPC601 


QFP-304 


Soldered 


TMS540 + Opt 11 + 
Opt 22 + Opt 12 




68340 


QFP-144 


Soldered 


TMS260 + Opt 02 + 






136 








(AC-PGA4-QF10-68340, 




MPC601 


N/A 


S/W only 


TMS540 


136 








Contact Emulation Tech)*® 


102 


MPC603 


QFP-240 


soldered 






68360 


PGA-241 


Socketed 


TMS261 + Opt 01 + Opt 22 


102 


1 ivijD+u + upi. 1 1 + 
Opt 22 + Opt 13 


136 


68360 


QFP-240 


Soldered 


TMS261 + Opt 01 + Opt. 22 + 




MPC603 


N/A 


S/W only 


TMS540 


136 








(#5968C, Contact Pomona)*® 


102 


MPC603e 


N/A 


S/W only 


TMS540 


136 


88K 










MPC603ev_ 


N/A 


S/W only 


TMS540 


136 


68000 


DIP-64 


Socketed 


TMS201 + Opt 01 


68 


MPC604 


N/A 


S/Wonly 


TMS540 


136 


68000 


PGA-68_^ 


Socketed 


TMS201 + Opt. 02 


68 


MPC604e 


N/A 


S/W only 


TMS540 


136 


68000 


PLCC-68 


Socketed 


TMS201 + Opt 03 


68 


MPC740 


N/A 


C/lA/ nnl\/ 






68000 


PLCC-68 


Soldered 


TMS201 + Opt. 02 + 
013-0250-00 + 103-0312-00 


68 




jf vv uiiiy 


IIVIjDHI, IOi DVjM riODe, 

LA-BGA-740-S-B-01, 
Contact Ironwood Electronics*’ 


136 


68EC000 


PLCC-68 


Socketed 


TMS201 + Opt 04 


68 


MPC750 


N/A 


S/W only 


TMS541; for BGA Probe, 
LA-BGA-750-S-B-01, 




68EC000 


PLCC-68 


Soldered 


TMS201 + Opt 04 


68 






68HC000 


DIP-64 


Socketed 


TMS201 + Opt 02 


68 








Contact Ironwood Electronics*’ 


136 


68HC000 


PGA-68 


Socketed 


TMS201 + Opt 02 


68 


MPC801 


N/A 


S/Wonly 


TMS561 


102 


68HC000 


PLCC-68 


Socketed 


TMS201 + Opt 03 


68 


MPC821 


N/A 


S/W only 


TMS560; for BGA Probe, 




68HC000 


PLCC-68 


Soldered 


TMS201 + Opt 02 + 
013-0250-00 + 103-0312-00 


68 








BCP-357-2BG019Z-MPC860-1-TEK-PN, 
Contact Emulation Tech*® 


102 


68010 


DIP-64 


Socketed 


TMS201 + Opt 01 


68 


MPC823 


N/A 


S/W only 


TMS561;for BGA Probe, 
LA-BGA-850-Z-B-01, 
Contact Ironwood Electronics*’ 




68010 


PGA-68 


Socketed 


TMS201 + Opt 02 


68 








102 


68010 _ 


PLCC-68 


Socketed 


_ TMS201 + Opt03 


68 


MPC850 


N/A 


S/W only 


TMS561;for BGA Probe, 
LA-BGA-850-Z-B-01, 




68010 


PLCC-68 


Soldered 


TMS201 + Opt. 02 + 












013-0250-00 + 103-0312-00 


68 _ 








Contact Ironwood Electronics*’ 


102 


68020 


PGA-114 


Socketed 


TMS202 + Opt 01 


102 


MPC860 


N/A 


S/W only 


TMS560;for BGA Probe, 




68020 


QFP-132 


Soldered 


TMS202 + Opt 03 


102 




BCP-357-2BG019Z-MPC860-1-TEK-PN, 




68EC020 


PGA-100 


Socketed 


TMS202 + Opt 02 


102 








Contact Emulation Tech*® 


102 



www.tektronix.com/Measureinent/logic_analyiers/ 



LOGIC ANALYZERS 141 



Channels 



Device 


Package 


Usage 


Order These Items: Required 


MOTOROLA (CONTINUED) 

MPC8260 N/A S/W only 


TMS562; for BGA Probe, 
LA-BGA-8260-S-B-01, Contact 
Ironwood Electronics*^ 


136 


POWERPC 

PPC403CA 


N/A 


S/W only 


TMS531 


102 


PPC403GC 


N/A 


$/Wonly 


TMS531 


102 


PPC403Ca 


N/A 


S/W only 


TMS531 


102 


MPC505 


N/A 


S/W only 


TMS550 


102 


MPC509 


N/A 


S/W only 


TMS550 


102 


PPC601 


QFP-304 


Soldered 


TMS540 + Opt n + Opt 22 + Opt 12 136 


PPC601 


N/A 


S/W only 


TMS540 


136 


PPC603 


QFP-240 


Soldered 


TMS540 + Opt 11 + Opt 22 + Opt 14 136 


PPC603 


N/A 


S/W only 


TMS540 


136 


PPC603e 


N/A 


S/W only 


TMS540 


136 


MPC603ev 


N/A 


S/W only 


TMS540 


136 


PPC604 


N/A 


S/W only 


TMS540 


136 


PPC604e 


N/A 


S/W only 


TMS540 


136 


PPC740 


N/A 


S/W only 


TMS541; for BGA Probe, 
LA-BGA-740-S-B-01, 
Contact Ironwood Electronics*^ 


136 


PPC750 


N/A 


S/W only 


TMS541;for BGA Probe, 
LA-BGA-750-S-B-01, 
Contact Ironwood Electronics*^ 


136 


MPC801 


N/A 


S/W only 


TMS561 


102 


MPC821 


N/A 


S/W only 


TMS560; for BGA Probe, 
BCP-357-2BG019Z-MPC860-1-TEK-PN, 
Contact Emulation Tech*® 


102 


MPC823 


N/A 


S/W only 


TMS561;for BGA Probe, 
LA-BGA-850-Z-B-01, 
Contact Ironwood Electronics*^ 


102 


MPC850 


N/A 


S/W only 


TMS561;for BGA Probe, 
LA-BGA-850-Z-B-01, 
Contact Ironwood Electronic*^ 


102 


MPC860 


N/A 


S/W only 


TMS560; for BGA Probe, 
BCP-357-2BG019Z-MPC860-1-TEK-PN, 
Contact Emulation Tech*® 


102 


MPC8260 


N/A 


S/W only 


TMS562; for BGA Probe, 
LA-BGA-8260-S-B-01, 
Contact Ironwood Electronics*^ 


136 


ROCKWELL 

6502 N/A 


S/W only 


Contact Cust. Supt Cntr *^ 


68 


65802 


N/A 


S/W only 


Contact Cust Supt Cntr.*^ 


68 


SIEMENS 

80C161 

80C165 


N/A 

N/A 


S/W only 
S/W only 


Contact Ingenieurbuero Strunck*^ 
Contact Ingenieurbuero Strunck*^ 


102 

102 


80C166 


N/A 


S/W only 


Contact Ingenieurbuero Strunck*^ 


102 


80C167 


N/A 


S/W only 


Contact Ingenieurbuero Strunck*^ 


102 


80C167 


PQFP-144 


Soldered 


TMS600 + Opt01 


102 


80C515 


N/A 


S/W only 


Contact Cust. Supt Cntr.*^ 


68 


ST MICROELECTRONICS (THOMPSON) 

ST10-1 XX N/A S/W only Contact Ingenieurbuero Strunck*’ 


68 



Channels 

Device Packafe Usage Order These Items: Required 



TSQWARE 

TS701 


N/A 


S/W only 


Contact Cust. Supt Cntr.*® 


136 


TS702 


N/A 


S/W only 


Contact Cust. Supt Cntr.*^ 


136 


SOCKET 7 

AMD K6-2 
100 MHz 


PGA-321 


Socketed 


TMS109A + Opt01 


136 


6x86 


PGA-296 


Socketed 


TMS109A + Opt01 


136 


6x86 100 MHz 


PGA-296 


Socketed 


TMS109A + Opt01 


136 


P54C 


PGA-296 


Socketed 


TMS109A + Opt01 


136 


P55C 


PGA-296 


Socketed 


TMS109A + Opt01 


136 


Pentium 


PGA-296 


Socketed 


TMSI09A + Opt 01 


136 


Winchip 


PGA-296 


Socketed 


TMS109A + OPL01 


136 


TEXAS INSTRUMENTS 






C2000 










TMS320C2XLP 


N/A 


S/W only 


Contact Cust. Supt Cntr.*^ 


102 


TMS320C207 


N/A 


S/W only 


Contact Cust. Supt Cntr.*® 


102 


TMS320C209 


N/A 


S/W only 


Contact Cust Supt Cntr.*^ 


102 


TMS320C27XX 


N/A 


S/W only 


Contact Cust Supt Cntr.*^ 




C5000 










TMS320C548 


N/A 


S/W only 


Contact Cust Supt Cntr.*® 




C6000 


TMS320C6201 


N/A 


S/W only 


TMS710; for BGA Probe, 
BC-VI-2-26ZD/1, 
Contact Emulation Tech*® 


102 




TMS320C6701 


N/A 


S/W only 


TMS710; for BGA Probe, 
BC-VI-2-26ZD/1. 
Contact Emulation Tech*® 


102 




C2X/3X/«X/5X 


TMS32020 


PGA-68 


Socketed 


Contact Cust. Supt Cntr.*^ 


68 


TMS32020 


PLCC-68 


Socketed 


Contact Cust Supt Cntr.*^ 


68 


TMS320C25 


PGA-68 


Socketed 


Contact Cust. Supt Cntr.*^ 


68 


TMS320C25 


PLCC-68 


Socketed 


Contact Cust. Supt Cntr.*’ 


68 


TMS320C26 


PLCC-68 


Socketed 


Contact Cust. Supt Cntr.*® 


68 


TMS320G0 


PGA-181 


Socketed 


TMS702 + Opt01 


102 


TMS320C31 


QFP-132 


Soldered 


TMS702 + OPL02 


102 


TMS320C32 


N/A 


S/W only 


Contact Ingenieurbuero Strunck*^ 


102 


TMS320C40 


N/A 


S/W only 


Contact Cust Supt Cntr.*^ 


102 


TMS320C50 


N/A 


S/W only 


Contact Cust. Supt Cntr.*’ 


102 


TMS320C51 


N/A 


S/W only 


Contact Cust Supt Cntr.*^ 


102 


TMS320C52 


N/A 


S/W only 


Contact Cust. Supt Cntr.*^ 


102 


TMS320C53 


N/A 


S/W only 


Contact Cust. Supt Cntr.*® 


102 


TMS470 


N/A 


S/W only 


Contact Cust Supt Cntr.** SEE ARM 


102 


ZILOG 

Z80 


DIP-40 


Socketed 


TMS501 +optm 


68 


Z80 


DIP-40 


Soldered 


TMS501 + Opt 01 + 015-0646-00 


68 


Z180 


N/A 


S/Wonly 


Contact Cust. Supt. Cntr.*® 


102 



142 LOGIC ANALYZERS 



www.tektronix.con/MeasurenMnt/logic_analyzers/ 



Device 



(.nanneis 



BUS SUPPORT 

1553A/B N/A 


N/A 


Contact Cust. Supt. Cntr.*^ + 
PN 010-0572-00 


102 


AGP 


N/A 


Socketed 


TMS806 + Opt 01 


136 


AGP4X 


N/A 


Socketed 


Contact Cust Supt Cntr.*^ 


136 


Rambus -Direct RIMM 


Socketed 


TMS810+ Opt 01 


238 


SCSI I/ll "A" 


Unshielded 











Ribbon 




TMS802 + Opt 01 


102 


SCSI I/ll X 


Shielded 








(8-bit) 


Ribbon 




TMS802 + Opt 01 


102 


SCSI I/ll “A" 


Shielded 








(8-bit) 


High-density 




TMS802 + Opt01 


102 


SCSI II "P" 


Shielded 








(16-bit) High-density 




TMS802 + Opt01 


102 


APIC Bus (InteO 




TMS801 + Opt 01 


102 


GPIB 




S/Wonly 


Contact Cust. Supt Cntr.*^ 


j68 


PCI 






NEX-PCI Contact New Wave PDG*’ 


102 


PCI32 @ 3 V 






VNEX-PCI32EXHD3 










Contact New Wave PDG*’ 


102 


PCI32 @ 5 V 






VNEX-PCI32EXHD5 










Contact New Wave PDG*’ 


102 


PCI64 @ 3 V 






VNEX-PCI64EXHD3 










Contact New Wave PDG*’ 


102 


PCI64 @ 5 V 






VNEX-PCI64EXHD5 










Contact New Wave PDG*’ 


102 


PCI Mezzanine Cd. 




NEX-PMC 










Contact New Wave PDG*’ 


102 


Cardbus 






NEX-CARDBUS 










Contact New Wave PDG*’ 


68 


Compact PCI 




NEX-CPCI Contact New Wave PDG*’ 


102 


32864 PCI-SW 




S/Wonly NEX-PCISW Contact New Wave PDG*’ 102 


S-DIMM 


168-Pin 


Socketed 


NEX-SDIMM168 










Contact New Wave PDG*’ 


136 


VME 




NEX-VME Contact New Wave PDG*’ 


102 


ISA 




NEX-EISA Contact New Wave PDG*’ 


102 


EISA 




NEX-ISA Contact New Wave PDG*’ 


102 


Micro Channel 




NEX-MCA Contact New Wave PDG*’ 


102 


SIMM 


72-Pin 


Socketed NEX-SIMM72 Contact New Wave PDG*’ 102 


PCMCIA 




NEX-PCMCIA Contact New Wave PDG*’ 102 


USB basic 






CHS-USB-1LC 




suppot 


N/A 


Contact Crescent Heart Software*^ 


68 


USB 






CHS-USB-lOP 




Optimized Perf. 


N/A 


Contact Crescent Heart Software*^ 


68 


USB High 






CHS-USB-IXP 




Performance 


N/A 


Contact Crescent Heart Software*^ 102/136 


I2C 


N/A 


S/Wonly 


Contact Cust Supt Cntr.*^ 




Mil-1750A Generic N/A 


S/W only 


Contact Cust Supt Cntr.*^ 




PROBING ACCESSORIES 






Mictor Breakout 




NEX-HDEXT Contact New Wave PDG*’ 


Mictor to 










20-pin header 




NEX-HD20 Contact New Wave PDG*’ 




Mictor Swizzle 










Board 




NEX-HDSWIZ Contact New Wave PDG* 


1 



Order directly from: 

New Wave PDG. 59 Daxis Ave.. Norwood, MA 02062, USA. 

(603) 595-8116 (phone). (781) 762-9445 (fax). 

E-mail: husboards@aol.com . http://www.busboards.com 
Order directly from: 

Ironwood Electronics. P.O. Box 21151, St. Paul. MN 55121, USA, 

(651) 452-8100 (phone). (651) 452-8400 (Fax). 

E-mail: info@ironwoodelectronics.com. 
h ttp :/ /mnv. iron woodelectronics. com 
Order directly from: 

Crescent Heart Software. 2143 SE 55th Ave. . Portland. OR 97215-3925. 
USA. (503) 232-2232 (phone), (503) 232-2255 (Fax), 

E-mail: sales@c-h-s.com, http://www.c-h-s.com 
*"* Order directly from: 

Dragonfly Software Development LLC, 8196 Southivest Hall Blvd. 

Suite 104. Beaverton. OR 97008. USA, 

(503) 641-3440 (phone). (503) 641-7226 (fax). 

E-mail: sales@dfsw.com. http://www.dfsw.com 
Order directly from: 

Ingenieurbuero Strunck. Aplerbecker str. 443c, D-44287 Dortmund. 
Germany. 49-231-447126 (phone). E-mail: salimh@t-online.de 
Order directly from: 

Emulation Technology'. 2344 Walsh Avenue. 

Bldg. F. Santa Clara. CA 95051, USA, 

(408) 982-0660 (phone). (408) 982-0664 (fax). (800) ADA-PTER. 
h ttp :/ /WWW. em ula tion . com 
Order directly from: 

JM Engineering. 3502 East Boulder Street. Colorado Springs. CO 80909. 
USA. (719) 591-1 1 19 (phone), (719) 637-1777 (fax), 
http:/ /ix'ww. deltaprobe. com/ 

Order directly from: 

ITT Pomona. 1500 East Ninth Street. Pomona. CA 91766-3835. USA. 
(909) 469-2900 (phone). (909) 629-3317 (fax), 
h ttp :// w^nv. pomomaelectronics.com 
Order directly from: 

Tektronix Customer Support Center, 

(503) 627-2400 (phone). (800) 835-5695 (toll free in USA). 

(503) 627-5695 (fax), 

http://w\\'w.tek.com/Measurement/Support 



www.tektronix.coi^/Measaremeiit/losic_aiialyzers/ 



LOGIC ANALYZERS 



143 




RF AND Wireless Test Products 



Contents 

Spectrum Analyzers 145 

Network Analyzers 200 

Power Meters 212 

Signal Generators 225 

EMI/RFI Solutions 246 

Wireless Communication 

Test Sets 266 



Tektronix RF and Wireless Test Capabilities 
Cover a Broad Spectrum 

Tektronix offers a value-packed line of RF. microwave and wireless communication 
test products. The list includes a wide selection of spectrum analyzers, signal genera- 
tors, network analyzers, communication test sets, and power meters, along with com- 
plementary ancillary equipment and software covering the following applications: 

► Avionics 

► Bio-Medical 

► Cable TV 

► Common Carrier 

► Design and Development 

► Education 

► EMC 

► EW 

► Manufacturing Test 

► Millimeter Test 

► Millimeter Wave R & D 

► Radar 

► Research 

► Satellite Communication 

► Service 

► TV/Radio Broadcasting 

► Wireless Communications 



144 



RF AND WIRELESS TEST PRODUCTS 



www.tektronix.com/Measurement/commtest/ 



Spectrum Analyzers 



Spectrum Analyzers 

INTRODUaiON 

Tektronix offers a broad range of spectrum analyzers. The selection ranges from 
high performance, high throughput models for communications test to lightweight, 
battery powered units suited for field use. 

EXTENSIVE PRODUCTS FOR COMMUNICATIONS TEST 

Testing mobile communications systems presents many unique challenges. 
Tektronix has products designed for meeting the specific measurement require- 
ments of CMDA, GSM, IS-136 and AMPS along with the emerging next generation 
(3G) systems. In addition to spectral analysis, powerful code domain and modula- 
tion domain analysis options are available on several models. 

REAL TIME SPECTRUM ANALYZERS OFFER NEW MEASUREMENT CAPABILITIES 

Tektronix’ new range of real time spectrum analyzers provide new data capture and 
analysis capabilities. The DSP/FFT based architecture acquires RF data in parallel 
instead of sweeping. The benefits of real time spectrum analysis include: 

► Acquiring seamless blocks of RF data for immediate or post-analysis 

► RF event triggering for capturing elusive events 

► Modulation and code domain analysis (3066 and 3086 only) 

SPECTRUM ANALYZERS FOR RADIO COMMUNICATION 

FSEB20/30 

FSEA20/30 

FS1Q3/7/26 

R3465 

R3463 

R3267 

MICROWAVE SPECTRUM ANALYZERS 

FSEM20/30 

FSEK20/30 

R3272 

R3273 

REAL TIME SPECTRUM ANALYZERS 

3026 



3066 



Contents 

spectrum Analyzer 



Selection Guides 146 

3066/3086 150 

3026 153 

FSIQ3/7/26 156 

FSEA20/30 160 

FSEB20/30 160 

FSEM20/30 160 

FSEK20/30 160 

R3267/R3273 170 

R3272 174 

R3465/63, 3263 176 

R3561/3561L 180 

U3661 182 

R3132/R3162 185 

U3641/N 188 

R3131 192 

2711/2712 194 

2704/2705 198 

2707 199 



3086 

GENERAL PURPOSE SPEaRUM ANALYZERS 

R3131 

U3641 

R3132 

R3132/N 

R3162 

2712 

2711 

U3661 



www.tektronix.com/Measurement/commtest/ 



SPECTRUM ANALYZERS 



145 



Spectrum Analyzer Selection Guide 



•K 



N 

>- 

—I 

< 

Z 

< 

3 



Q. 

in 

LU 

> 

< 

0 ^ 

u 

il 



MM 



er Z 

2 E 

3 g 

y t 3 



«S g- 
E Q. 
•K TS 



E. 

oO M 

15 

i-R 

o 

^2 



E 5 ; 

^ E 

i /1 : — > 


2 E 



■K --g 
^ 5 

O) ^ 

I 

t H 3 



i= % 
o 5 

r-n > 
oO 

O 



o 



tsi M X 

XX M M o ^ 

o o X X ^ o 

irj in «J O ifj 

vb vb o o rM 13 

fS fN «!i- o ^ 

0 o o o; o 

^ M ^ 

M M M M: X ^ 

5 ^ 5 ==: o S 

01 ° at S 2 CTi 



o o 



o o 



fN m I 

5 5 S 

LU LU LU LU rN fN 

m m m *n iO 

LU Li- LU U- OC 



ro ro 
< < 
E E 

3 3 

•c -c 




w f 5 g 3 g c 

2 l3 Q- Cf <J ll. < 



146 



SPECTRUM ANALYZERS 



www.tektronix.com/Measurenieiit/coniiiitest/ 



Modulation 

GPIB 

RS-232 



Spectrum Analyzer Selection Guide 



to 

Z 

o 

h- 

< 

h! o 

z 'S 

o 
u 



G 

< 

Ctl 

o 



to 

0 ^ 






< 

z 

< 



D 

Of 



Q. 

LO 



I 



$ 

’1 



-o E 

0^ o 

oi -o 

I'l 

QJ fO 

11 



^ I 



E S 

^ (D 

S:T5 



X 

v:? X X t:? X o 
in tn O O in O 
rn in r«. rn r>. rN 

o o o o o o o 

M N Nl NJ! M N Nl 

X X X X X X X 
-^ 0-^0 000 
a* fS 0> <N fS rN <N 



f 

oo 

I- 

(O ^ 

E 5 



g'd a 

I 

m . , 

^ I— •— 

E ^ ^ 
£ c c 
^ ID 'fo 

$r E E 
-S -S 

VE O) OI 



r '5 5 
^ < < 
is s 

E o o 

2 tj tj 
2 o o 



oa .= 

o o 



o o o o 



VO 



rM m rs ro — 

— ^ — •* MM MM ^ ^ 

IS s Su 9!9[<y 

If li! t£ If! 2 



'CEE 



X $ ^ 



3 X X 

^ ^ o 



o ;55 

— OV ov 



3 = X 
^ O 



o- 

51 



^ 2 i 



! 



^ 2 



I 2 



o> 2 

M 

— X 

+1 o 
— qJ 
o E 



- E 

M 2 ; 

3 



E ^ 

CQ o 

■° 5 

rN „ 
vn o 

I in 



X 

5 ±f 



S £ £ 

e S 2 

Oi OI 
fO »D 

c c 

< < 

E E 

3 3 

■c -c 



G 

o 

z 

o 



uj « 

LO S 

UJ 

N 

>• 

_l 

< 

Z 

< 



^ W 

a 

2 in: 
M *i 
X 



S' “ 
§ 

qv T 



I i 
s -5 

2 i 2 S 
CO o E 
M 2 i 

— X 3 
+IC 5 jn 

— a< 

o E 



E y ^ 



M 

X 


U- 


X 

5 a, 
in ^ 


V /1 


"5 

X ^ 


0 

00 

0 


I £ 
in 0 


i'l 
s s 


£ 


•O' 0 

00 M 

-a X 


M 

X 


fM 

+1 — 


3^ 


M 

X 


2 li 


01 


(§) 


M in^ 

3: 

0 


m 

V 


' m 






0 

m 







^ X _ 

@) # S 

^ 

S O rn 

^ O 5 

E S 



2 : :£ 
X ^ 



o in 



X . 
^ rM 



'CD' 2 CO 
OQ . "O 

■® b g 
0^0 
g M rs 

^ S 



I t 

2IS e: 



2 ^ 

! 2 E 
M 2i 
X 3 
t o 1/1 

>— OI 

o E 



=S: § 5 
S; o ^ 



Q. 

Ln uT 



MO 



OI 

i £ ^ 

^ flj 



= Xi 2 o{ 
: 2 






= X 
in o 



1 ° ^ 

^ b § 

Vg M <N 
^ X 

5 



2 ° £ 
M ro N|‘ 
X X 
m 
V 



"CD- o 
00 M 
-O X 



2 s £ 

CO o E 
■O M E 
— X 3 

+' ^ IS. 

OI; 

o El 



IJ- z 



; n: 2 



2 ^ 



5 i:: 

i:S! 



g 






s 

O 






o 

o 

o ■ 

o 00 



^ “ 
§ 



(§)^ # £ 
:=' a 

.3 

: §: o ^ 

^ in : 

: E 2; iE: 
□0 0 

00 



•i 3 <0 ; 



S' 

■q 



E 

> c 
;-E o 

i/) .b: 

g' ^ 

in LU 



,i 

^1 

op jS 

12 



§■ 

K ; 






«/i : VO 

: 2 ; C:: 



:gii o; 



n: z 



S a. 
«o o 
o 3 g: 



.E 

■Si 



•i 









S; 



fo Si 

o SZ 



rs =! 

-S: 

g; g 1 

“ gi 

CJC 3i 

^ 51 



Q CL 
DO £ 



ID ^ 

= T5i 

1 ! 



£i^: 



Si o S 



www.tektronix.com/Measurement/commtest/ 



SPECTRUM ANALYZERS 147 



•H 

I 



to 



N 

>• 



- ! 
It 



o> o. 

E o 

§■ ^ 

_ o> 



a ^ 

to 

3 ^ 

I 1 

^ I 



< _ 

Z t 

< ■ 

b 



0. 

to 

—I 

< e 

0^ .S 

LU ra 

Z g, 

Ul ■“ 

O 



TT M M 

£1^ 5S£ 

O yjj vq vq 
to rs oi to CO 



XXX 
^ ^ ^ 
CT> CT> 0% ; 



! £ I 



ro rtJ 
< < 
e: e 



x; 

I O' 



LU 

Q 

15 

o 

z 

o 

t- 

u 

LU 

LU 

cn 



M 

>- 



^ ‘O •>! 

«e VO X 

5 rM ^ 



U 



21 ^ ^ 



x^ ^ 



f I 

E E ; 

& cu 



00 rM , — 



O 

O 



O 









1/1 LD 

^ CO 



0.^(1 i/i 

e e s 

ee ss S S o in 



vi > 



OQ QQ 

-o "ra 
CO rs 



S = J- 

“ -g- 



>->->•>- 



^ z :Si ^ ^ S 



9" 3= 



0 . 

0 


V 


X! 

'D' 

CO 

• 3 ; 


X 




o' 


s 




V 


0 






tsl 

X 







•& Q 
Oj wo 



i,i^ 



9- 3: 

Q. ^ 



u t 

o 



'i^ O '♦•I 

X — VI 

> 



■SJi 

fi : 

M 

X; 

(M °o 
0^-0 

i§‘$i 

■&• 



to o 



O 

>■ 



^ Z Z ^ 



;lj ^ U5 



Z ^ 



Z ^ ^ Z 



£ S 

<u 

5 o> = 5 

^ So 52 -o 

3 g c S E 

S «o ^ »o 

O os S CD 

■“I I" I" er I 



5^ £■ 



a. 

LO 



*5 2- 



^3^0 oo rs 52 "S. ^ 

2f tl S ^ S -2 Si 

QCQl OH O- O U- 



tO • — 

C ^ 

<u O 
E ”1^ 

C (L» 

> '5 (o 

C Oi 

LU > tU 



I ■§ 

“! "O 



■5 O 
^ «u 



rji 

0^ Oi 

S 02 

O Q_ 



3 E 

Qu OJ 

Q = Q 

2? E S 
o E u_ 



5T "re 



it O D lC < rC 



I ‘ - 

1 „ R 1 o 

•3 £9 «3 < 

o VO !o O 

5 O 02 O. > 



148 SPECTRUM ANALYZERS 



www.tektronix.oMi^MeasHreneiit/coiniiitesl/ 



Spectrum Analyzer Selection Guide 



£-■2 



S E 
o 

OO 

.£ ^ 
•S Cl. 



^ E 



to 

3 

OO "CJ 

•I s 



LU UO 



M 

> 

< 

Z 

< 



o o 

CO CO 



D 

Of 



Q. 

to 



< _ 
“ s 



Z K 

LU M 

U a 



D 

o 

z 

o 

h- 

U 



oc 

LU 

fsl 

> 



3 IS 

q: o 



Q. 

LO J? 



X 
; ^ 
■ rs 

VI 



o 

BO 



I i 



-S-. 



^ LJ 



£ 5 VI o 



‘ E .2 - ' 

ca ^ <^ = 
■ 0^01 

§ ' 

+ 1 > fN: - 

E hf ( 

CO •, > 

* 0 : 



Q. s« F 
O _ 






, ^ ^ ^ ^ ^ o 



° S 

ts 



o ?= 



m: X 



■? i 

E 



E- I' 



Q£ 2 CQ 

er cr 



E. S ^ 



;> 



cr o- o. 

2i 2i a) S 

Ll. Ll- ai 0£ 



O 

% 

e 

.tl 

op 5 

i S 



■S: 



U-! ^ 

o ^ 

^ o i 

^ ^ C o) 



<o ^ 



Q § 



■ 5 S VJ -a 



CiJ o^i 

E 



Q- _ 
5 - .S 2 - 



Q Q . -2 

op = s -2 



ro iz 3 

i; I I 



! fM 

/vs' 

29 fS 



3 



& : 

I: 



.E»=L-»Q.cyv-;u:< 



< 5 o 



LO 

q: 

UJ 

M 

>- 

u 

< 

Z 

< 

2 

D 

0^ 



Q. 

to 



I 

-* FJ 

< Si| 

LLI *2 

Q:: o 



' < 

Q 



•fo o 

I O 

= $ 
(Ui o 
•Oi ex 
P c 



•sa ^ “■ 

T5 E JC. 
c ^ 
««. o 

i 2| 

I ol 

<u .i£! ® 



'ol .2 o 

"o ^ ^- 



o7 E E 



c= c: 



X X 
O 



5 ; . 2 P. 2 P 
X S a) 

-s 

E E 



fo O O. 

to Kl’ 



^ ^ ^ 
oii o). ^ 

C C ^ C i 

E E E 

3 3 3 

■c -c -B 

OJ QJ QJ . 

Q- CX CX L, 

I/O uo t /> 

o» Ol 7 ” 

E E E U 



CO 

Z 

o 

I- 

< 

u 



Q£ Q£ a: 



Q. 

to 



5 -jJ . *J 

^ /S- 

O: O 

^ ^ ^ I; 



I 

rsi; 



Xi 



O: 



i/» in «/) rs 
’ • ^ I 0 » Ol _ 

m m* Z >-f>-.:>- Z 



;■£ 



M: op 

£|Q: 



X. 



IS «o 

S 5' 



g -i: 

g:|’gj^ 

I s £; I 

j 2 >eO^: 0 - 

^ ofl ; gf 



www.tektronix.com/Measurement/commtest/ 



SPECTRUM ANALYZERS 149 




Real-Time Spe 

New 3066 • New 3086 



CTRUM Analyzers 




Features - Benefits 



Seamless Acquisition for Capture of 
Short Duration or Intermittent 
Events 

Analyzes in Frequency, Time and 
Modulation Domain 

DC to 3 GHz Coverage 

Frequency Event Trigger for 
Acquisition of Burst or Infrequently 
Occurring Signals 
Post Capture 1000:1 Zoom Allows 
Analysis of Individual Signals after 
Wideband Capture 



Applications 



1st, 2nd, and 3rd Generation 
Cellular/PCS R&D - Including GSM, 
CDMA, IS-136, PDC, W-CDMA 

Signature Analysis 
Spectrum Monitoring 

Settling Time Measurements for 
Oscillators and Synthesizers 

Phase Hit Capture and 
Measurement 

Debugging of Hardware/Software 
Interface Problems 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 

ce 



Product(s) complies with IEEE 
Standard 488.1-1987, RS-232-C, 
and with Tektronix Standard 
Codes and Formats. 



SONY 

Tfektfpnix, 




609002 Cc«MM 
JMI-mt3 



The 3066 aiid 3086 are DC to 3 GHz real-time 
spectrum analyzers that allow the seamless cap- 
ture of frequency spectra with spans up to 30 MHz 
(5 MHz - 3066). This allows the spectrum of burst 
signals, such as those from GSM, lS-136, PDC or 
partial rate CDMA mobile stations, to be easily 
captured and examined. Real-time spectrum 
analyzers take a whole different approach com- 
pared to traditional sweeping spectriun analyzers. 
Rather than acquiring one frequency step at a 
time, the real-time instrument captures a block of 
frequencies all at once. Because the instrument 
.samples these frdl frames constantly (rather than 
waiting for each discrete frequency step to be 
measured), the signal can come or go as it pleases 
and the real-time spectrum analyzer v^ll detect 
the change instantly. 

The 12.1 in. color TFT display allows easy view- 
ing of spectrum, waterfall displays, spectrograms 
and digital modulation analysis screens. 
Constellation and vector diagrams can be dis- 
played as well as frequency, phase, magnitude, 

1 and Q versus time for in-depth analysis of digi- 
tally modulated signals. Users can move a marker 
through the time record and analyze the modula- 



tion at any point. In particular, signals with 
symbol rates up to 20.48 Msymbols/sec (3066 - 
5.3 Msymbols/sec) may be analyzed during and 
after capture. This facilitates analysis of W-CDMA 
signals with chip rates up to 16.384 Mcps. 

In addition, a frequency mask trigger allows the 
capture of randomly occurring or infrequent sig- 
nals such as intermittent spurious emissions. If 
the user is not interested in the period between 
transmission bursts, the frequency mask trigger 
allows capture of the “burst-on” periods, thus 
maximizing the number of bursts that can be cap- 
tured in memory for subsequent spectral, time or 
modulation analysis. The user can graphically 
define the frequency trigger mask; this allows the 
trigger condition to be generated by a particular 
event in the frequency domain irrespective of 
other activity within the displayed span. This is 
a major benefit when the trigger condition is used 
to capture signals arising from intermittent spuri- 
ous or spectral re-growth events. 

A 1000:1 zoom capability permits analysis to be 
performed on an individual signal in a multi- 
signal environment. 



150 SPECTRUM ANALYZERS 



www.tektronix.com/Measurement/commtest/ 







Real-Time Spectrum Analyzers 

NEW 3066 • NEW 3086 



Characteristics 



INPUT/MEMORY MODE RELATED 
Input Mode - RF, Baseband; Wideband, IQ 
(3086 only). 

Input Connector - N type (RF, Baseband, 
Wideband), BNC type (IQ). 

Input Impedance - 50 Q. 

VSWR (N type) - 1.5 (Reference Level 
>-20 dBm). 

Acquisition Mode - Roll, Block. 

Acquisition Memory Size - 16 Mbytes. 
Acquisition Memory Management - 

RF, Baseband Input 

Memory Mode: Frequency, Dual, Zoom. 

FFT Points: 1024, 256 (Frequency Mode). 

FFT Window: Rectangular, Hamming, 
Blackman-Harris. 

Block Size: 

1 to 16,000 Frames (Frequency Mode, 256 pt). 
1 to 4,000 Frames (Frequency Mode, 1024 pt). 
1 to 2,000 Frames (Dual, Zoom Mode). 
Minimum Frame Update Time: 

20 ps (Frequency Mode, 256 pt). 

80 ps (Frequency Mode, 1024 pt). 

160 ps (Dual, Zoom Mode). 

Wideband, IQ Input (3086 only) - 
Memory Mode: Zoom. 

FFT Points: 1024. 

FFT Window: Rectangular, Hamming, 
Blackman-Harris. 

Block Size: 1 to 2,000 Frames. 

Minimum Frame: 25 ps. 

Frequency Standard Related 

Characteristic Description 



Reference frequency 


10 MHz 


Initial frequency tolerance 


± 0.1 ppm 


Frequency stability Aging 


± 0.0005 ppm/day 


Temperature 


± 0.002 ppm 




(5 to 40° Q 



RF INPUT RELATED 
Frequency - 

Range: 10 MHz to 3 GHz. 

Center Frequency Settability: 0.1 Hz. 
Span: 100 Hz to 3 GHz. 

Vector Span: 100 Hz to 6 MHz. 

Real-time Span: 100 Hz to 5 MHz. 
Number of Bins: 

641 (100 Hz to 2 MHz span). 

801 (5 MHz span). 

481 (6 MHz span). 

Span/6250 + 1 (span > 10 MHz). 
Spectrum Purity: -100 dBc/Hz (1 GHz CF, 
200 kHz span, 0 dBm ref, 10 kHz offset). 
Residual FM: 3 Hz p-p. 

Amplitude - 

Reference Level: -50 dBm to +30 dBm. 



Maximum Nondestructive Input Power: +30 dBm. 
Self Gain-Calibration Accuracy: ±1.0 dB at 
25 MHz within 5®C temperature variation. 
Flatness: ±2.0 dB (10 MHz to 3 GHz). 

Input Equivalent Noise: -140 dBm/Hz. 

3rd Order Distortion: -65 dBc (-10 dBfs input, 
at 1 GHz). 

Residual Response: -70 dBfs (0 dBm ref, 

5 MHz span). 

Image Suppression: 70 dB. 

Spurious Free Dynamic Range (1 GHz CF, 

0 dBm REF, sinusoidal signal at the center, spur 
apart more than 10 kHz from the signal): 

80 dB at 50 kHz span. 

75 dB at 100 kHz span. 

70 dB at 200 kHz and 500 kHz span. 

65 dB at 1/2/5 MHz span. 

BASEBAND INPUT RELATED 
Frequency - 

Range: DC to 10 MHz. 

Center Frequency Settability: 0.1 Hz. 

Span: 100 Hz to 10 MHz. 

Vector Span: 100 Hz to 6 MHz. 

Real-time Span: 100 Hz to 5 MHz. 

Number of Bins: 

641 (100 Hz to 2 MHz span). 

801 (5 MHz and 10 MHz span). 

481 (6 MHz span). 

Spectrum Purity: -100 dBc/Hz (5 MHz CF, 

200 kHz span, 0 dBm ref, 10 kHz offset). 
Residual FM: 2 Hz p-p. 

Amplitude - 

Reference Level: -30 dBm to +30 dBm. 
Maximum Nondestructive Input Power: +30 dBm. 
Reference Level Accuracy: ±0.5 dB at 5 MHz. 
Flatness: ±1.0 dB (1 MHz to 10 MHz). 

Input Equivalent Noise: -150 dBm/Hz. 

2nd Harmonic Distortion: -70 dBc (at 4.5 MHz). 
DC Offset: -40 dBfs. 

Residual Response: -70 dBfs (5 MHz CF, 

5 MHz span, 0 dBm ref). 

Alias Suppression: 65 dB. 

Spurious Free Dynamic Range (5 MHz CF, 

0 dBm ref, sinusoidal signal at the center, spur 
apart more than 10 kHz from the signal): 

85 dB at 50 kHz span. 

80 dB at 100 kHz span. 

75 dB at 200 kHz span. 

70 dB at 500 kHz span. 

70 dB at 1/2/5 MHz span. 

WIDEBAND INPUT RELATED 
(3086 ONLY) 

Frequency - Range: 50 MHz to 3 GHz. 

Center Frequency Settability: 0.1 Hz. 

Span: 10 MHz, 20 MHz, 30 MHz. 

Vector Span: 10 MHz, 20 MHz, 30 MHz. 

Number of Bins: 

501 (10 MHz and 20 MHz span). 

751 (30 MHz span). 



Amplitude - 

Reference Level: -50 dBm to +30 dBm. 
Maximum Nondestructive Input Power: +30 dBm. 
Flatness within Span: ±1 dB (25® C ±5® C). 
Input Equivalent Noise: -140 dBm/Hz. 

3rd Order Distortion: -65 dBc (-10 dBfs input, 
at 1 GHz). 

Residual Response: -60 dBfs (0 dBm ref, 

30 MHz span). 

Image Suppression: 70 dB. 

Spurious Free Dynamic Range (1 GHz CF, 

0 dBm ref, sinusoidal signal at the center, spur 
apart more than 500 kHz from the signal): 

65 dB at 10 MHz span. 

60 dB at 20 MHz and 30 MHz span. 

IQ INPUT RELATED (3086 ONLY) 
Frequency - 

Range: ±15 MHz. 

Span: 10 MHz, 20 MHz, 30 MHz. 

Vector Span: 10 MHz, 20 MHz, 30 MHz. 

Number of Bins: 

501 (10 MHz and 20 MHz span). 

751 (30 MHz span). 

Amplitude - 

Reference Level: 100 mV (amplitude of IQ signal). 
Maximum Nondestructive Input Power: ±5 V. 
Flatness within Span: ±0.5 dB (25® C ±5® C). 
Residual Response: -60 dBfs (30 MHz span). 
Alias Suppression: 55 dB. 

Spurious free dynamic range (1 GHz CF, 0 dBm 
ref, sinusoidal signal at the center, spur apart 
more than 500 kHz from the signal): 

65 dB at 10 MHz span. 

60 dB at 20 MHz and 30 MHz span. 

FRAME TIME RELATED 



Frame 


Time ( 3086 ) 




Span 


1024 point 


256 point 


Baseband Mode: 


10 MHz 


80 us 


20 ps 


RF Mode and Baseband Mode: 


6 MHz 


80 ps 


20 ps 


5 MHz 


160 ps 


40 ps 


2 MHz 


320 ps 


80 ps 


1 MHz 


640 ps 


160 ps 


500 kHz 


1280 ps 


320 ps 


200 kHz 


3200 ps 


800 ps 


100 kHz 


6.4 ms 


1.6 ms 


50 kHz 


12.8 ms 


3.2 ms 


20 kHz 


32 ms 


8 ms 


10 kHz 


64 ms 


16 ms 


SkHz 


128 ms 


32 ms 


2 kHz 


320 ms 


80 ms 


1 kHz 


640 ms 


160 ms 


500 Hz 


1280 ms 


320 ms 


200 Hz 


3200 ms 


800 ms 


100 Hz 


6400 ms 


1600 ms 



www.tektronix.com/Measurement/commtest/ 



SPECTRUM ANALYZERS 151 





Real-Time Spectrum Analyzers 

NEW 3066 • NEW 3086 



1024 point 



256 point 



Wideband/IQ Input Modes: 3086 Only 


30 MHz 


25MS 




25 MS 


20 MHz 


25 MS 




25 MS 


10 MHz 


50 MS 




5p|JS 



TRIGGER RELATED 

Trigger Mode - Auto, Normal, Quick, 

Delayed, Interval, Quick-interval, Timeout, 

Auto, Normal [RF (span < 6 MHz) and 
Baseband Input, Wideband and IQ Input (3086 
only)]. 

Trigger Source - Internal/External. 

Trigger Domain - Frequency, Time. 

Trigger Position - 0 to 100%. 

Frequency Trigger Mask - 
Frequency Resolution: 1 bin. 

Trigger Level Range: 0 dBfs to -70 dBfs. 

Time Trigger Mask - 
Time Resolution: 1 data point. 

Trigger Level Range: 0 dBfs to -40 dBfs. 
External Trigger Threshold Level - 1.6 V. 

MARKER ZOOM RELATED 
Marker - 

Marker Type: Normal, Delta, Band-Power. 
Search Function: Peak Right, Peak Left, 
Maximum. 

Link between Views: On/Off. 

Measurement Function - Noise Power, 
Power within Band, C/N, Adjacent Channel 
Power, Occupied Bandwidth. 

Digital Zoom - 

Zoom Ratio: 2 to 1000. 

Maximum Span in the Zoom Mode: 5 MHz (RF, 
Baseband), 30 MHz (Wideband, IQ, 3086 only). 



Digital Demodulation Related 



Characteristic 

Demodulator 

Carrier type 
Modulation format 

Measurement filter 
Reference filter 
Filter parameter 
Maximum symbol rate 

Standard setup 


ucscripnon 

Continuous, Burst 

BPSK, QPSK, pi/4 Shift DQPSK, 8PSK, 
OQPSK, 16QAM, 64QAM, GMSK 
Root Cosine 
Cosine, Gauss 

alpha/BT: 0.0001 to 1, 0.0001 step 
5.3 Msps (RF, Baseband); 20.48 Msps 
(Wideband, IQ; the 3086 only) 
PDC, PHS, NADC, TETRA, GSM, 
CDPD,lS-95.T-53 


Display format 


Symbol/locus display. Frequency error 
measurement. Origin offset measurement 


Vector diagram 


Constellation diagram 


Symbol display, Frequency error 
measurement Origin offset measurement 


Eye diagram 


l/Q/Trellis display ( 1 to 16 symbols) 


Error vector diagram 


EVM, Magnitude error. Phase error, 
Waveform quality (rho) measurement 


Symbol table 


Binary. Octal, Hexadecimal 


Error measurement accuracy 


10 frames averaged 


PDC 


EVM <1.2 % Mag error <1.0 %, 
Phase error <0.8° (100 kHz span) 


PHS 


EVM <1.4 Mag error <1.2 %, 
Phase error <0.8° (1 MHz span) 


GSM 


EVM <1.8 %, Mag error <1.2 %, 
Phase error <1.0° (1 MHz span) 


IS-95 reverse link 


EVM <2.0% (5 MHz span) 


QPSK, 4.096 Msps, 2 GHz 


EVM <2.5 % (20 MHz span) 


QPSK, 16.384 Msps, 2 GHz 


EVM <3.0 % (30 MHz span, 25° C ±5° C) 



SYSTEM CONTROLLER 

Pentium MMX 200 MHz, 64 Mbyte SIMM, 
Windows 95, PCI, ISA, TMP68301 16 MHz, 

2.1 Gbyte 3.5 Inch EIDE, 1.44 Mbyte floppy 
drive, GPIB IEEE488.1, Keyboard PC/AT (order 
separately), Centronics parallel port, SCSI 2. 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



3086 

Real-time Spectrum Analyzer. 

Includes: User Manual, U.S. Power Cord, mouse. 

3066 

Real-time Spectrum Analyzer. 

Includes: User Manual, U.S. Power Cord. 

OPTIONS 

Opt. IS - Data capture software. 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of calibration services. 
Opt. C5 - Five years of calibration services. 

Opt. 01 - Test Data. 

Opt. 03 - Test data (requires Opt. C3). 

Opt. R3 - Three years of repair protection. 



INTERNATIONAL POWER PLUGS 
Opt. A1 - Universal Euro 220 V, 50 Hz. 
Opt. A2 - United Kingdom 240 V, 50 Hz. 
Opt. A3 - Australian 240 V, 50 Hz. 

Opt. A4 - North American 240 V, 60 Hz. 
Opt. AS - Switzerland 220 V, 50 Hz. 

See page 619 for description. 

RECOMMENDED ACCESSORIES 
PC Display Analysis Software - 

3066: Order SL7PC66. 

3086: Order SL7PC86. 



For your local Tektronix representative see the list in 
the oack of this catalog or outside the U.S. call: 
1-S03-627-1916, inside the U.S. call: 1-800-426-2200. 

C€ 



Product(s) complies with IEEE Standard 488.1-1987, 
RS-232-C, and with Tektronix Standard Codes and Formats. 



S ONY 

Ttektronix 




60900? c«ntl«) 



jM(-on3 



152 SPECTRUM ANALYZERS 



www.tektronix.com/ Measuremeirt/commlest/ 




Real-time Spectrum Analyzer 

New 3026 




Features - Benefits Applications 



2 MHz Real-time Signal Capture 

Simultaneous Time and Frequency 
Domain Capture 

50 Hz to 3 GHz Frequency 
Coverage 

Frequency, Time and Phase 
Analysis 

25,000 Frames/Second 
Measurement Speed 

Display Update Rate of 
40 Microseconds 



Cellular/PCS Manufacturing Test 
Pager Manufacturing Test 

RF Component Manufacturing Test 
Including DLL and Synthesizer 
Settling 

Network Ingress Monitoring and 
Analysis 

CATV Return-path Ingress Monitoring 

Radar System Fault Location and 
Maintenance 

Microwave Data Link Fault Location 

Computer Manufacturing/Test for 
EMC 

Surveillance 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 

C€ 

GPIB 

ICH4U 

Product(s) complies with IEEE 
Standard 488.1-1987, RS-232-C, 
and with Tektronix Standard 
Codes and Formats. 



SONY 

Ttektronix 




609002 CettilKd 
JW0113 



The new 3026 real-time Spectrum Analyzer pro- 
vides design engineers and manufacturing final 
test evaluators of communications equipment an 
affordable product that can be used to quickly 
evaluate a design or the final product for tran- 
sient (Burst) phenomena that otherwise might 
not show up until it is in the end user’s hands. 

The 3026 offers a full 2 MHz of real-time band- 
width with measurement speed of 25,000 
frames/second and a 1024 point update interval 
of 160 microseconds. The captured events can be 
conveniently displayed in a variety of formats 
selectable by the user: Spectrum, Spectrogram 
and Waterfall. The analyzer architecture makes it 
possible to capture time domain data and fre- 
quency domain data simultaneously. 

To catch instantaneous phenomenon like a trans- 
mitter startup, or the beginning of a digital 
TDMA or CDMA transmission, the 3026 pro- 
vides frequency domain and time domain real- 
time triggering with a mask pattern that is easily 
edited in the built-in editor. 



Application Examples 

DIGITAL CELLULAR/PCS DESIGN, TEST AND 
MANUFACTURE 

Current spectrum analyzers do not do a very 
good job of analyzing burst or intermittent sig- 
nals. They sweep over a band of frequencies and 
are therefore not able to capture simultaneously 
the spectrum over a band of frequencies. This 
makes it difficult, or sometimes impossible, for a 
developer to identify problems, such as phase 
jumps, which will adversely affect a digitally 
modulated system. 

Transient noise burst problems that are often 
associated with high frequency solid state com- 
munications equipment can be captured with a 
measurement speed of 25,000 frames/second and 
a 1024 point update interval of 160 microsec- 
onds reducing intermittent problem test time. 

EMC 

Common Carrier and CATV Network operators 
have to deal with Ingress that can disrupt trans- 



www.tektronix.coin/Measurement/commtest/ 



SPECTRUM ANALYZERS 153 





Characteristics 



Real-time Spectrum Analyzer 

NEW 3026 



mission in both the forward and return 
paths. This interference is often impul- 
sive in nature and very difficult to cap- 
ture with a conventional spectrum ana- 
lyzer. The 3026 with its real-time cap- 
ture capability allows rapid detection 
and analysis of such interference. 

In the screen photo (1) (lower section 
of photo) below an interfering burst 
4.8 MHz above the spectrum center is 
captured for analysis. In tlie upper 
spectrogram section the amplitude vs. 
frequency of the complete spectrum is 
displayed as a function of time (vertical 
axis). In the Spectrogram display, each 
line of pixels represents a frame, with the 
most recent frame displayed at tlie bottom. 

TRANSITIONAL SIGNAL ANALYSIS 

Bursting signals such as TDMA employ 
Phase Locked Loops (PLL) for frequen- 
cy stability, a critical measiuement of 
interest is the frequency change as the 
transmitter is keyed on and ofl. 

The 3026 can capture tliis transition in 
time, frequency and phase as shown in 
this screen capture. 

In the lower portion of the photo (2), 
we can see the change in Frequency 
vs. Time (spectrogram) and in the 
upper portion of the display we can 
see the phase change during transmit- 
ter activation. From this example, we 
find this transceiver makes a signifi- 
cant frequency, amplitude and phase 
shift until it stabilizes. 



FREQUENCY RELATED 
Frequency Range - 

RF Mode: 10 MHz to 3 GHz. 

Baseband Mode: 50 Hz to 10 MHz. 

Frequency Span - 

RF Mode: 100 Hz to 3 GHz. 

Baseband Mode: 100 Hz to 10 MHz. 

Stability of Frequency Standard - 

± 5 X lO'Vday. 

Residual FM - 3 Hz max. 

Spectrum Purity - -100 dBc/Hz (10 kHz offset). 

Center Frequency Settabiiity - 0.1 Hz. 

AMPLITUDE RELATED 
Reference Level Range - 

RF mode: -50 to -i-30 dBm. 

Baseband Mode: -30 to +30 dBm. 

Input Impedance - 50 Q. 

Flatness - 

±2.0 dB (>500 Hz). 

+2.0, -5.0 dB (<500 Hz). 

Input Equivalent Noise - 
-140 dBm/Hz at 1 GHz. 

2nd Harmonic Distortion - 
<-70 dBc (-10 dBfs Input Level). 

3rd Order Distortion - 

<-60 dBc (<20 MHz, <-10 dBfs Input). 

<-70 dBc (<20 MHz, <-10 dBfs Input). 

A/D Converter - 12-Bits, 25.6 MS/s. 

FFT points - 1024, 256 

FFT window - Blackman-Harris, Hamming, 

Rectangle. 

Minimum Frame Update Rate 



Span 


1024 point 


512 point 


500 kHz to 5 MHz _ 


16 MS 




500 kHz to 2 MHz 




40 p 


50 kHz to 200 kHz 


400 ps 


400 ps 


5 kHz to 20 kHz 


4 ms 


4 ms 


500 Hz to 2 kHz 


40 ms 


40 ms 


200 Hz 


100 ms 


100 ms 


100 Hz 


200 ms 


200 ms 



TRIGGER RELATED 

Trigger Mode - Auto/Normal (Frequency and 
Time Events). 



1) Signal Ingress. 




2) PLL Frequency Settling. 




3) Pulsed Signal. 




4) CDMA Mobile Phone. 







SPECTRUM 



ANALYZERS 



www.tektronix.com/IVIeasurement/commtest/ 



154 










Real-time Spectrum Analyzer 

NEW 3026 



SYSTEM CONTROLLER 

486DX4-100 (100 MHz Clock), 32 MB 60 ns 
Fast Page SIMM (non-parity), 2.5 inch 3 MB 
Solid State Drive, 2.5 inch 2.1 GB Hard Disk, 

3.5 inch 2 HD (1.44 MB) Floppy Disk, On Board 
Ethernet LAN l/F, ISA Half Size GPIB. 

POWER 

Line Voltage Range - 90 to 250 VAC. 

Line Frequency - 48 to 63 Hz. 

Maximum Power - 300 W. 

Maximum Current - 4 A. 

Fuse Rating - 6 A, 250 V, Fast blow. 

Primary Circuit Dielectric Voltage 
Withstand Test - 1500 V rms, 50 Hz for 
15 seconds, without breakdown. 



Physical 


Characteristi 


ICS 


Dimensions 


mm 


in. 


Height 


165 


6.5 


Width 


376 


14.8 


Depth 


495 


19.5 


Weight 


kS 


lb. 


Net 


13 


29 



WARRANTY 

One year parts and labor. 

SAFETY 

UL3111-1, CSA231, EN61010-1, IEC61010-1. 
Self-declaration - EN61010-1 with second 
amendment. 

For more comprehensive and environmental 
specifications, please see the Tektronix website. 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



3026 

Real Time Spectrum Analyzer. 

Includes: (For U.S.) User Manual (Japanese 
070-A676-02), Programmer's Manual (Japanese 
070-A682-00), Application Software, Utility 
(VIEW3026, 3.5 in. Floppy. 062-A225-00), Power 
Cord (Power Cable Assy, 161-A005-00), 3-2 Adapter 
(103-0013-00). 

Includes: (All other countries) User Manual 
(English 071-0418-00), Programmer's Manual 
(Japanese 071-0419-00), Application Software, Utility 
(VIEW3026, 3.5 in. Floppy. 062-A255-00), Power 
Cord (Power Cable Assy, 161-0230-01). 

OPTIONS 

Opt. 1R - Rackmount Kit. 



INTERNATIONAL POWER PLUGS 
Opt. A1 - Universal Euro 220 V, 50 Hz. 

Opt. A2 - United Kingdom 240 V, 50 Hz. 
Opt. A3 - Australian 240 V, 50 Hz. 

Opt. A4 - North American 240 V, 60 Hz. 

Opt. AS - Switzerland 220 V, 50 Hz. 

See page 619 for description. 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of calibration services. 
Opt. C5 - Five years of calibration services. 
Opt. 01 - Cal Data Report. 

Opt. D3 - Test data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover 
three years. 



OPTIONAL ACCESSORIES 

Transit Carrying Case - Order 016-1157-00. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

C€ 



Product(s) complies with IEEE Standard 488.1-1987, 
RS-232-C, and with Tektronix Standard Codes and Formats. 



S ONY 

Tfaktfpnix 




609002 CetUM 
JMI 0113 

SPECTRUM ANALYZERS 155 



www.tektronix.com/Measurement/commtest/ 





Applications 




Signal Analyzer 

New FSIQ 




For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 



Features - Benefits 



Vector Signal Analyzer for W-CDMA 

High-speed Synthesizer with 5 ms 
Sweep Time for FULL SPAN 
(FSIQ3/7) 

High Display Update Rate up to 
25 sweeps/s 

Large Color Display with High 
Resolution (24 cm/9.5 in. TFT) 

Analysis of Frequency, Time and 
Modulation Domain in One Box 

82 dB ACPR (Adjacent Channel 
Power Ratio) in 4.096 MHz 
Integration Bandwidth for Alternate 
Channel 

True RMS Detector for Precise and 
Repeatable Measurements of Any 
Signal Type 

3 Models and Frequency Ranges 
-FSIQ 3: 20 Hz to 3.5 GHz 
-FSIQ 7: 20 Hz to 7 GHz 
-FSIQ 26: 20 Hz to 26 GHz 

FFT Filter with 1 Hz to 1 kHz RBW 
for Fast Measurements 
Third-order Intercept -i-20 dBm with 
FSIQ 7/26 

Total Measurement Uncertainty: 

- <1 dB up to 2.2 GHz 

- <1.5 dB up to 7 GHz 

Fast Time Domain Analysis with 
1 ps Zero Span Sweep Time 



Vector Analysis of W-CDMA and 
Other Wireless Signals 

For Universal Analysis of Digital and 
Analog Modulated Signals BPSK to 
16QAM, (G)MSK, AM, FM, PM 

For High-throughput Production 
Applications 

Coverage for Wireless and 
Aerospace Applications 



C€ 



ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



FSIQ - THE One Box Solution in 
Signal Analysis 

FSIQ provides in a single unit comprehensive 
and easy-to-use measurement functions in the 

► Frequency domain 

► Time domain 

► Modulation domain 



FREQUENCY DOMAIN 

In the frequency domain, FSIQ measures inter- 
modulation and harmonics with great accuracy. 
The high 3rd-order intercept point in conjunc- 
tion with the extremely low noise floor yields an 
intermodulation-free dynamic range of >110 dB 
and ensures reliable performance of even sophis- 
ticated measurements. 



156 SIGNAL ANALYZERS 



www.tektronix.com/Measurement/commtest/ 




Signal Analyzer 

NEW FSIQ 



The excellent dynamic range and the 
optimized phase noise values make the 
FSIQ an ideal tool for ACPR (Adjacent 
Channel Povy^er Ratio) measurements in 
all mobile radio systems and in particu- 
lar for W-CDMA. The maximum ACPR 
value for W-CDMA in 4.096 MHz band- 
width is 75 dB, attained at -12 dBm 
input level. 

The RMS detector available for all 
band widths up to 10 MHz is the ideal 
tool for precise power measurements 
whatever the waveform. Channel power 
and adjacent-channel power can accu- 
rately be measured and displayed irre- 
spective of any signal statistics. Typical 
measurement problems such as the high 
and uncertain crest factor in CDMA sys- 
tems can thus be eliminated and the 
true RMS value displayed. 

TIME DOMAIN 

In the time domain, FSIQ features all 
modern capabilities of burst analysis in 
TDM A systems; gate functions, trigger 
delay and integrated RF trigger in con- 
junction with a short sweep time of 
1 ps ensure precise measurement of the 
timing characteristics of all main 
mobile radio systems. 

Thanks to the wide range of bandwidths 
available up to 10 MHz the effect of the 
measuring instrument becomes negligi- 
ble, particularly in the case of measure- 
ments on broadband systems. 

Various marker functions in conjunction 
with editable gated sweeps allow RMS, 
average and peak measurements to be 
carried out over any selectable time. 

MODULATION DOMAIN 

In the modulation domain, the integrat- 
ed vector signal analyzer provides 
diverse measiuements on signals with 
digital or analog modulation. The vari- 
ety of settings that can be called simply 
at a keystroke covers 18 mobile radio 
standards from GSM, NADC, IS95 
through to W-CDMA. These convenient 
presets make it superfluous for the user 
to spend valuable time in looking up 
specifications and go towards enhanc- 
ing the measurement reliability. 

Display of the results caters to practi- 
cally each and every need: in addition 
to vector and constellation diagrams, 

I/Q signal and eye/trellis diagrams, 



tables with modulation errors including 
the demodulated bit sequence are par- 
ticularly useful. EVM (error vector mag- 
nitude), phase and frequency error, 
waveform factor and I/Q offset are out- 
put as numeric values, with RMS and 
peak value being shown separately. 

Besides the mobile radio standards, 

FSIQ can also be used as a general pur- 
pose measurement demodulator for non- 
standard modulation methods. The list 
of the 14 digital demodulators available 
ranges from BPSK, QPSK and (G)MSK 
through to 16QAM. Witli a symbol rate 
selectable up to 6.4 Msymbol/s and 
cosine and root-cosine filters adjustable 
in 0.01 step width, configuration of cus- 
tomized systems is no problem. 

The analog demodulators using digital 
technique throughout feature long term 
and temperature-independent measure- 
ments, e.g., of transmitter transients, or 
convenient measurement of incidental 
phase modulation (AM to phiM conver- 
sion) e.g., on traveling wave tubes. 

HIGH MEASUREMENT SPEED 
FOR USE IN DEVELOPMENT 
AND PRODUCTION 

► The minimum sweep time for FULL 
SPAN is 5 ms (FSIQ3/7). The sweep 
is synthesizer-controlled for all fre- 
quency settings, thus providing con- 
siderably higher accuracy of the dis- 
played spectra than comparable 
spectrum analyzers 




Rear View of FSIQ. 



► The shortest sweep time in ZERO 
SPAN mode is 100 ns/div and ideal 
for high-resolution time measure- 
ments on burst edges 

► Up to 25 sweeps/s is an optimal 
prerequisite for applications in 
production or fast alignments with 
“analog feeling” 

► High throughput on GPIB bus saves 
time and costs in production 




www.tektronix.com/Measurement/commtest/ 



SIGNAL ANALYZERS 157 






Signal 

NEW FSIQ 



Analyzer 



Firmware and Software Options 



Use 



Functions 



Noise measurement software 


• ir~ 

FS-K3 


Noise figure 
measurements 

Editor for ENR tables 


Measurement of noise 
figure and temperature 
to Y-factor method 
Measurements on 
frequency-converting DUTs 
Frequency range same as 
basic unit starting from 100 kHz 
Runs under Windows 


Phase noise 
measurement software 


FSE-K4 


Phase noise measurements 


Easy to use phase noise 
measurements 
Measurement of residual 
FM an PM 
Logarithmic plot 
over 8 decades 
Runs under Windows 


Application firmware 


FSE-K10, Mobile, 
FSE-Kll, BTS 


Mobile radio, 
transmitter 
measurements 
GSM standards, 
11.10 and 11.20 


Power ramp and power template 
Spectrum due to modulation/ 
switching 

Spurious emissions 
Mean carrier power 
Phase/frequency error 
(with Option FSE-B7) 


See separately available data sheet. 


1 Characteristics I 


General Data 


FSIQ3 


FSIQ7 


FSIQ26 


Display 




24 cm color display TF (9.5") 




Resolution 




640 X 480 pixels (VGA resolution) 




Mass memorv 




1.44 MB 3.5 in. floppy disk drive, hard disk 




Onoratino Temoeratm Ranfe 


~r « 1 

Nominal temperature range 




+5° C to +40° C 




Limit temperature range 




0° C to +50° C 




Storage temperature range 




-40° C to +70° C 




Hiimirlitv 




+40° C at 95% relative humidity (lEC 68-2-3) 




Power SuddIv 


rr-t 

AC supply 




200 V to 240 V: 50 Hz to 60 Hz, 
100 V to 120 V: 50 Hz to 400 Hz, 
protection class 1 to VDE 411 




Power consumption 


195 VA 


210 VA 


245 VA 


Safety 




EN 61010-1, UL 3111-1, CSA1010, 1EC61010-1 




Test mark 




VDE, GS, UL, cUL 




Phvsical Characteristics 


Dimensions in mm 
fW X H X D) 


435 X 236 X 460 


435 X 236 X 570 


435x236x570 



Weight 



24kt. 



24-5kg 



26.5 kg 



158 



SIGNAL ANALYZERS 



www.tektronix.coin/Measurement/cofflnite$t/ 




Signal Analyzer 

NEW FSIQ 




Phase noise for FSIQ3 (light gray) and FSIQ7/26 (dark gray). 



Ordering Information 



For price information; Outside the U.S. contact your local Tektronix representative, inside the U.S. see 



FSIQ3 

Signal Analyzer 20 Hz to 3.5 GHz. 

Order 1119.5005.03. 

Includes: Keyboard. Mouse, Power Cable, Operating 
Manual, Spare Fuses. 

FSIQ7 

Signal Analyzer 20 Hz to 7 GHz. 

Order 1119.5005.07. 

Includes: Keyboard, Mouse, Power Cable, Operating 
Manual, Spare Fuses. 

FSIQ26 

Signal Analyzer 20 Hz to 26.5 GHz. 

Order 1119.6001.26. 

Includes: Keyboard, Mouse, Power Cable, Operating 
Manual, Spare Fuses. 

Accessories Supplied - 

Test-Port adapter 3.5 mm female. Order 1021.0521.00. 
N female. Order 1021.0535.00. 

OPTIONS 

HARDWARE 

FSE-B2 - 7 GHz Frequency Extension for FSIQ 3. 
Order 1073.5044.02. 

FSE-B8 - Tracking Generator 3.5 GHz. 

Order 1066.4469.02. 

FSE-B9 - Tracking Generator 3.5 GHz with 
l/Q Modulator. Order 1066.4617.02. 

FSE-B10 - Tracking Generator 7 GHz. 

Order 1066.4769.02. 

FSE-B11 - Tracking Generator 7 GHz with 
l/Q Modulator. Order 1066.4917.02. 

FSE-B12 - Switchable Attenuator for Tracking 
Generator. Order 1066.5065.02. 

FSE-B16 - Ethernet Interface 15-contact ADI connec- 
tor. Order 1073.5973.0. 

FSE-B16 - Thin-wire BNC connector. 

Order 1073.5973.03. 

FSE-B17 - 2nd lEC/IEEE Bus Interface. 

Order 1066.4017.02. 



FSE-B21** - External Mixer In/Output for FSIQ26. 
Order 1084.7243.02. 

FSE-B22*^ - Increased Level Accuracy up to 2 GHz. 
Order 1106.3480.02. 

SOFTWARE 

FS-K3 - Noise Measurement Software. 

Order 1057.2996.02. 

FSE-K4 - Phase Noise Measurement Software. 

Order 1108.0088.02. 

FSE-K10 - GSM Test Software, Mobile. 

Order 10573092.02. 

FSE-Kll - GSM Test Software, BTS. 

Order 1057.3392.02. 

RECOMMENDED EXTRAS 

FSE-Z1 - Service Kit. Order 1066.3862.02. 

FSE-Z3 - DC Block, 5 MHz to 7 GHz, N-connector. 
Order 4010.3895.00. 

FSE-Z4 - DC Block 10 kHz to 18 GHz, N-connector 
Order 1084.7443.02. 

FS-Z15 - Microwave Measurement Cable and 
Adapter Set for FSIQ26. Order 1046.2002.02. 
Headphones - Order 0708.9010.00. 

19 IN. RACK ADAPTER 

ZZA-95 - With front handles. Order 0396.4911.00. 
ZZA-951 - Without front handles. Order 0396.9488.00. 
ZZG-95 - Set of Front Handles. Order 0396.5176.00. 
ZZK-954 - Transit Case (FSIQ3/7). Order 1013.9395.00. 



the price list in the back of this catalog. 

ZZK-955 - Transit Case (FSIQ26 only). 

Order 1013.9408.00. 

ZZK-1 - Trolley. Order 1014.0510.00. 

MATCHING PADS, 75 Q 

RAM - L section. Order 0358.5414.02. 

RAZ - Series resistor, 25 Q. Order 0358.5714.02. 
ZRB2 - SWR Bridge, 5 MHz to 3000 MHz. 

Order 0373.9017.52. 

ZRC - SWR Bridge, 40 kHz to 4 GHz. 

Order 1039.9492.52. 

HIGH-POWER ATTENUATORS, 100 W 

RBU 100 - 3/6/10/20/30 dB. Order 1073.8820.XX 
(XX = 03/06/10/20/30). 

HIGH-POWER AHENUATORS, 50 W 

RBU 50 - 3/6/10/20/30 dB. Order 1073.8895.XX 
(XX = 03/06/10/20/30). 

ESH3-Z3 - Preamplifier, 9 kHz to 30 MHz. 

Order 0827.8016.52. 

ESV-Z3 - Preamplifier, 20 to 1000 MHz. 

Order 0397.7014.52. 

FOR FSIQ26 ONLY 

Test-Port Adapter, N male - Order 1021.0541.00. 
Test-Port Adapter, 3.5 mm male - 

Order 1021.0529.00. 

*1) Cannot he retrofitted. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

C€ 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



www.tektronix.com/Measurement/commtest/ 



SIGNAL ANALYZERS 159 




Spectrum Analyzers 

FSEA20/30 • FSEB20/30 • FSEM20/30 • FSEK20/30 




Features - Benefits 



Spectrum Analysis with Ultra-wide 
Dynamic Range 

Universal Analysis of Digital and 
Analog Modulated Signals (Option) 
BPSK, QPSK, pi/4-DQPSK, QAM, 
MSK, OMSK, AM, FM, PM 

High-speed Synthesizer 
5 ms for Full Span (FSEA, FSEB) 

Refresh Rate, Quasi-analog 
25 Sweeps/s 
Large LC TFT Display - 
24 cm/9.5 in.. Active 

Future-proof Modular Design 
Customized Solutions through 
Wide Variety of Options 



Applications 



Spread Spectrum Channel Power 
Measurements 

High Dynamic Range 
Intermodulation Measurements 

Modulation Quality Measurements 

High Throughput Production 
Measurements 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 



ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



SPECTRUM ANALYZERS 

The FSE Series spectrum analyzers have been 
optimized for general-purpose measurements 
and meeting the stringent requirements of testing 
advanced digital communication systems. 
Extremely high measurement speed, future-proof 
modular design and excellent performance char- 
acteristics put these analyzers right at the top of 
today’s market - at a medium-range price. 

Easy upgrade of basic models into top-class 
models. 



VECTOR ANALYSIS FOR DIGITAL 
COMMUNICATION 

The analyzers of the FSE family combine the 
capabilities of high-end RF or microwave spec- 
trum analysis with those of universal digital- 
signal demodulation and analysis. This becomes 
possible with the vector signal analyzer option. 
The spectrum analyzer function offers the wide 
dynamic range necessary for many measiue- 
ments on digitally modulated signals (e.g., burst 
measurements), and the vector signal analyzer 
option adds demodulation capability to bit 
stream level for: 

► BPSK 

► piMDQPSK 

► GMSK 



► QPSK 

► 16 QAM 

► (G)FSK 



160 SPECTRUM ANALYZERS 



www.tektronix.com/Measurement/commtest/ 




Spectrum Analyzers 

FSEA20/30 • FSEB20/30 • FSEM20/30 • FSEK20/30 




All this is backed up by a variety of dis- 
play types: 

► Eye diagrams 

► Vector and constellation diagrams 

► Frequency and phase error 

► Vector error 

With a spectrum analyzer of the FSE 
family, you are perfectly equipped for 
the future of digital communication. 

MODULARITY SAFEGUARDS 
INVESTMENTS 

Series FSE analyzers are of modular 
design throughout. From the wide variety 
of options, you can choose exactly those 
needed for your particular application. 

You thus get an instrument tailor-made 
to your requirements and pay for no 
more tlian what you actually need. At 
the same time, you can feel sure that 
FSE will grow with yoiu tasks and 
requirements as most options can be 
retrofitted and model .20 units can easi- 
ly be upgraded later to almost the same 
performance as provided by top-class 
models .30. Even extending the frequen- 
cy range from 3.5 GHz to 7 GHz is no 
problem with Opt. FSE-B2. 

Your decision for Spectrum Analyzer 
FSE is a decision for a safe investment. 



www.tektronix.com/Measurement/comfntest/ 



Frequency 



Intermodulation, harmonics 
' Spurious 



Time 



Modulation 



Burst 

Power ramping 
Gated measurements 





Q CDMA PHP ISM WlAN 
GSM DCS 1800/1900 



DAB NADC TRS DECT SATELLITE RADAR MICROWAVE 




20 Hz 9 kHz 1 GHz 2 GHz 3.5 GHz 7 GHz 26.5 40 GHz 



Modular design for a safe investment. 



A TRIPLE RECORD HOLDER IN SPEED 

FSE breaks the speed record in three 
fields: 

► FSE features a minimum full-span 
sweep time of 5 ms (for FSEA and 
FSEB) with a fully synchronized 
sweep. This means that added speed 
is not at the expense of frequency 
accuracy but even enhances it 

► The shortest zero-span sweep time 
is 1 ps (100 ns/div) - ideal for high- 
resolution measurements on pulse 
edges 

► Up to 25 sweeps per second is an 
optimal prerequisite for rapid and 
easy alignments and for applications 
in production 

With its high measurement speed and 
great ease of operation. FSE will solve 
even highly complex measurement 
tasks in the shortest possible time. 



TOP DYNAMIC RANGE 

FSE is outstanding for its extremely low 
noise floor without any impairment to 
the dynamic range at large signal levels. 
This can be seen, for example, from the 
1-dB compression point of +10 dBm. 
which yields a dynamic range of 
109 dB even at a resolution bandwidth 
of 1 MHz, allowing GSM and DECT 
power ramps to be determined. 

The extremely wide intermodulation- 
free d\Tiamic range of typically 116 dB 
(FSEA30. FSEB30) and 105 dB (FSEB20, 
FSEB20) not only ensures reliable meas- 
tnements on highly linear amplifiers, it 
also enables detailed analysis of com- 
plex broadband signals. 

Taking as a figure of merit of an analyz- 
er the difference between its 3rd-order 
intercept point and its noise figure, 
FSEA can offer a value of around 0 dB. 



SPECTRUM ANALYZERS 161 








Spectrum Analyzers 

FSEA20/30 • FSEB20/30 • FSEM20/30 • FSEK20/30 



The FSE 

Option/ 

Function/ 

Software 


"Option 

Designation 


Building 

FSEA20 


Blocks" 

FSEA30 


FSEB20 


FSEB30 


FSEM20 


FSEM21 


FSEM30 


FSEK20 


FSEK30 


Frequency 
from 20 Hz 


- 


- 


s 


- 


s 


- 


- 


s 


- 


s 


Frequency 
to 3.5 GHz 


- 


s 


s 


- 


- 


- 


- 


- 


- 


- 


7-CHz 

Frequency 

Extension 


FSE-B2 


0 


0 


s 


s 






■ 


■ 


■ 


TV 

Demodulator 


FSE-B3* 


0 


0 


0 


0 


0 


0 


0 


0 


0 


Low Phase 
Noise 
and OCXO 


FSE-B4 


0 


s 


0 


s 


0 


0 


s 


0 


s 


FF Filter 


FSE-B5 


0 


s 


0 


s 


0 


0 


s 


0 





Vector 

Signal 

Analyzer 


FSE-B7 


0 


0 


0 


0 


0 


0 


0 


0 


0 


Tracking 
Generator 
3.5 GHz 


FSE-B8 


0 


0 




~ 


“ 




■ 


■ 




Tracking 
Generator 
3.5 GHz with 
l/Q Modulator 


FSE-B9 


0 


0 
















Tracking 
Generator 
7 GHz 


FSE-BIO 






0 


0 




■ 


0 




0 


Tracking 
Generator 
7 GHz with 
l/Q Modulator 


FSE-Bll 






0 


0 






0 




0 


Switchable 
Attenuator for 
Tracking 
Generator 


FSE-B12 


0 


0 


0 


0 


0 


0 


0 


0 


0 


Controller 


FSE-B15 


0 


0 


0 


0 


0 


0 


0 


0 


0 


Ethernet 

Interface 


FSE-B16 


0 


0 


0 


0 


0 


0 


0 


0 


0 


2nd lEC/IEEE- 
Bus Interface 


FSE-B17 


0 


0 


0 


0 


0 


0 


0 


0 


0 


Removable 
Hard Disk 


FSE-B18* 


0 


0 


0 


0 


0 


0 


0 


0 


0 


Second 
Hard Disk 
for FSE-B18 


FSE-B19 


0 


0 


0 


0 


0 


0 


0 


0 


0 


External 

Mixing 


FSE-B21 


- 


- 


- 


- 


0 


s 


0 


0 


0 


Increased 
Level Accuracy 
up to 2 GHz 


FSE-B22* 


0 


0 


0 


0 


0 


0 


0 


0 


0 


Broadband 
Output 
741.4 MHz 


FSE-B23* 


0 


0 


0 


0 


0 


0 


0 


0 


0 


Noise 

Measurement 

Software 


FS-K3 


0 


0 


0 


0 


0 


0 


0 


0 


0 


GSM 

Application 

Firmware 


FSE-K10/-K11 


0 


0 


0 


0 


0 


0 


0 


0 


0 



S = Standard. 0 = Can be retrofitted (option). *Factory-fitted only. 



162 SPECTRUM ANALYZERS 



www.tektronix.com/Measurement/commtest/ 



Spectrum Analyzers 

FSEA20/30 • FSEB20/30 • FSEM20/30 • FSEK20/30 



From AF to Microwave 

FSEM/K20/.30 open up the microwave 
range through to 26.5/40 GHz and 
retain the excellent characteristics of 
the 3.5 and 7 GHz basic models: 

► Continuous full-span sweep 

► Fundamental mixing, low noise floor 
as well as wide dynamic range up to 
26.5 GHz 

► Fully synchronized sweep with high 
frequency accuracy even for FULL 
SPAN (26.5/40 GHz) 

► RF input adapters for N or 
PC 3.5 mm, or with FSEK K 
male/female connector 

FSEM/FSEK with Opt. FSE-B21 allow 
frequency range extension by means of 
external mixers. Continuous automatic 
signal identification, which is used to 
suppress unwanted image frequency 
bands and mixture products, ensures 
fast and easy measurements. Due to the 
built-in diplexer, three-port as well as 
two-port mixers can be used. 

The external mixer measurement func- 
tion features great ease of operation: 

► Definition of frequency range and 
harmonics by selection of a wave- 
guide band 

► Definition of all important parame- 
ters for each waveguide band 
separately 

► Frequency-dependent consideration 
of mixer conversion loss 

► Storage of parameters on hard disk 

UNEQUALED MEASURING 
CONVENIENCE 

FSE makes measuring easy for you, 
offering a large number of convenient 
test functions: 

► Four markers, four delta markers 

► Marker functions for direct measure- 
ment of 

- Phase noise and noise power 
density (/Hz) 

- NEXT MIN/PEAK, NEXT 
MIN/PEAK RIGHT, NEXT 
MIN/PEAK LEFT 

- Bandwidths and shape factor 

► Measurement of channel power, 
adjacent channel power and occu- 
pied bandwidth 



www.tektronix.com/Measurement/commtest/ 



► Frequency counter with selectable 
resolution 

► LOW NOISE, NORMAL and LOW 
DISTORTION modes for low-inter- 
modulation and low-noise operation 

► One-button hardcopy on printer or 
plotter 

► Simultaneous measurement of four 
active traces 

► Level, frequency and user-definable 
limit lines as evaluation help with 
pass/fail information 

► Split screen with independent 
windows 

► Quasi-analog display 

FREQUENCY ACCURACY - 
TO-TH E-POINT 

Tuning an FSE is absolutely synchro- 
nous to the reference frequency for each 
span including full span. This means 
that every point on the frequency axis 
is determined with the accuracy of the 
internal reference frequency and the 
pixel resolution. Thus, when reducing 
the span for detailed signal analysis, 
readjustment of the center frequency is 
no longer needed. 

FSE in its basic configuration, includes 
an AM/FM demodulator. Unknown sig- 
nals can easily be identified via head- 
phones or the built-in loudspeaker. 
Modulation measurements are possible 
using the optional Vector Signal 
Analyzer (Opt. B7). 

Limit lines facilitate checking if results 
are within predefined tolerances. 
Virtually any number of limit lines can 
be defined with high accuracy by 
means of 50 points to meet even the 
most exacting requirements. 

Scalar Network Analysis 

The optional tracking generators are an 
ideal tool for determining frequency 
response, attenuation or VSWR and 
feature the following characteristics: 

► Wide dynamic range for attenuation 
measurements (up to 120 dB) 

► Frequency range from 
9 kHz to 3.5/7 GHz 

► Frequency offset up to ±200 MHz for 
measurements on frequency- 
converting modules 




Dynamic range, noise and 1 dB compression 
point for models of Spectrum Analyzer FSE. 




point. 



To generate digitally modulated signals 
the tracking generators with built-in I/Q 
modulator are ideal. An external two- 
channel Arbitrary Waveform Generator 
(e.g., AMIQ from Rohde&Schwarz) 
serves as the modulation source. 

By adding the optional Vector Signal 
Analyzer FSE-B7, FSE can be expanded 
to a test assembly enabling direct meas- 
urement of the influence of amplifiers 
or filters on phase error for instance. 

OPERATION - AS YOU LIKE IT 

Despite their comprehensive functional- 
ities the analyzers feature great ease of 
operation. Basic functions and frequent- 
ly used help tools such as markers can 
be called at a keystroke. The full operat- 
ing convenience based on a wide variety 
of evaluation routines and marker func- 
tions can be accessed via the menus. 

All essential parameters and results can 
be seen at a glance. All test data, scale 
factors and setting parameters are logi- 
cally arranged and thus easy to find. 
Setups, traces and graticules displayed 
in color make for error-free analysis of 
complex results. 



SPECTRUM ANALYZERS 163 



Spectrum Analyzers 

FSEA20/30 • FSEB20/30 • FSEM20/30 • FSEK20/30 




Rear of Spectrum Analyzer FSE. 

All models are equipped with a large 24-cm 
(9.5-in.) TFT color display with VGA reso- 
lution FSE6 (640 X 480 pixels). 

The USER key allows operation to be 
tailored to your specific requirements. 
With this key, you can compile the 
functions mainly needed for your meas- 
urement tasks, doing away with fre- 
quent menu changes and speeding up 
measurements on the whole. 

TEST RESULTS - PERFECTLY 
DOCUMENTED 

FSE affords uncomplicated logging of 
results. It supports a variety of printers 
and plotters. 

► FX-80 and compatibles 

► Printers with HP-PCL 

► HP-GL 

► Postscript 

Print files can not only be output via an 
interface but also be stored on diskette 
or the internal hard disk. With PCX, 
WMF and HP-GL print formats being 
available, there is no problem in further 
processing print files in standard text 
processing systems. Using Controller 
FSE-B15, it is particularly easy to gen- 
erate test reports and integrate the 
results. Texts can then be processed 
under Windows on FSE itself. 

FSE WORKS AS A CONTROLLER 

The optional Controller FSEB15 pro- 
vides an additional VGA card, 16 MB 
memory extension, serial mouse and a 
keyboard. FSEB15 is available in 
English and German and is supplied 
installed in FSE when ordered together 
with the unit. The option opens up the 
world of Windows 3.1 applications 
(standard mode) such as statistics pro- 
grams or spreadsheet analysis. FSE can 
even be linked to a network using the 
optional Ethernet Interface FSEB16. 



Complete setups, traces, limit lines and 
macros can be stored nonvolatile on the 
internal hard disk or on diskette with 
the built-in 1.44 Mbyte drive. 

FSE IN AUTOMATIC TEST SYSTEMS 

FSE is ideal for use in automatic test 
systems, affording not only fast process- 
ing of results and an lEC/lEEE-bus com- 
mand set conforming to SCPl. 

Moreover, the optional controller 
FSEB15 and a second lEC/IEEE-bus 
card (Opt. FSEB17), FSE can be used as 
a controller for test systems, thus elimi- 
nating the need for additional units and 
saving space in the system cabinet. 

MODULAR DESIGN - EASY 
RETROFITTING OF OPTIONS 

The easy concept for fitting the most 
important options, i.e.. Vector Signal 
Analyzer, Low Phase Noise and OCXO, 
7-GHz Frequency Extension, as well as 
the easy, adjustment-free incorporation 
of the remaining options make it possi- 
ble to retrofit the instrument with a 
minimum of downtime or installation 
costs being involved. 

NOISE MEASUREMENT 
SOFTWARE FS-K3 

FS-K3 turns your FSE into a noise 
measurement system offering the 
advantages of an analyzer (see also data 
sheet 757.2380): 

► From the large number of resolution 
bandwidths available, you can 
choose the right one for your appli- 
cation. even for measurements on 
narrowband DUTs 

► With ambiguous results, you can 
check your test system for EM pick- 
up or nonharmonics 

► The lower frequency limit is 100 kHz 

► Measurements on frequency-convert- 
ing DUTs are supported with the use 
of an external generator 

PHASE NOISE MEASUREMENTS 
WITH FSE-K4 

Phase Noise Measurement Software FSE- 
K4 extends the measurement capabilities 
of Rohde&Schwarz Spectrum Analyzer 
FSE phase noise testing. FSE is ideal for 
this purpose because of its low inherent 
phase noise and noise figure. 




1) TWo-tone measurements. 




2) Harmonics with split screen. 




3) Fundamental mixing to 26 GHz. 

High measurement speed is achieved 
through the high .sweep rates of FSE. It 
is possible to trade off speed again.st 
accuracy at small resolution band- 
widths (<1 kHz) by using either FFT or 
digital filters. FSE-K4 allows for differ- 
ent settings in one phase noise graph, 
e.g., FFT close and analog/digital filters 
far off the carrier. 

The software FSE-K4 runs under 
Microsoft Windows on FSE with con- 
troller function FSE-B15 fitted or on an 
external PC with GPIB controller. 



164 SPECTRUM ANALYZERS 



www.tektronix.com/Measurement/commtest/ 







Spectrum Analyzers 

FSEA20/30 • FSEB20/30 • FSEM20/30 • FSEK20/30 




I/Q signal and phase error measurements 
over 50 symbols of a GSM mobile. 



TV SIGNAL IN ZERO SPAN AND 
TV TRIGGER 

With a maximum resolution bandwidth 
of 10 MHz, implemented with the 
optional TV Demodulator FSE-B3, and 
the high resolution of 100 ns/div, FSE 
meets all requirements for the analysis 
of TV signals. In addition, FSE-B3 pro- 
vides the following functions: 

► Frame trigger 

► Line trigger with selection of line 

► CCVS output for connecting a moni- 
tor, adaptable to all standards 

Moreover, the quasi-analog display pro- 
vides luminance-signal information, 
enabling the detection of intermodula- 
tion products in the TV spectrum. 

Applications: 

RF POWER TRIGGER REPLACES 
EXTERNAL TRIGGER 

An internal broadband level detector 
(center frequency ±50 MHz) with a 
fixed switching threshold of approxi- 
mately -20 dBm at the first mixer is 
used as a trigger source. With this 
detector it is possible, for example, to 
perform “Spectrum due to switching’* 
and “Spectrum due to modulation” 
measurements to GSM specifications 
without an external trigger. Likewise, 
the detector replaces the external trigger 
needed in the gated sweep mode. 

GAP SWEEP: 

SIMULTANEOUS MEASUREMENT OF 
PULSE RISE AND FALL TIMES WITH 
HIGH TIME RESOLUTION 

The fast sweep time of 100 ns/div as 
well as the gap sweep and pretrigger 
functions of Spectrum Analyzer FSE 




























mmm 


■■■ 


IB 


B 


B 


B 


B 


■ihI 




















■ 








■hI 































Measurement of GSM power ramps to stan- 
dards with high-precision time reference 
through synchronization to mid-amble. 



make it possible to measure the rise and 
fall times of an RF pulse simultaneously 
and with high time resolution. The cen- 
ter of the pulse, which is of no interest, 
is blanked. Even at a resolution band- 
width of 1 MHz. FSE offers a dynamic 
range of over 80 dB thanks to the high 
1-dB compression point of +10 dBm. 

GATED SWEEP 

The gated sweep function is indispensa- 
ble for analyzing TDMA signals used in 
modern commimication systems. With 
this function, the spectrum of burst sig- 
nals can be investigated without any 
interference being caused by switching 
the signals on and off. The selected gate 
time determines over what interval a 
pulse is to be analyzed. Selection of the 
gate time is very easy and convenient in 
the time domain display (zero span) of 
the pulse. 

UNIVERSAL ANALYSIS OF DIGITAL 
SIGNALS 

Spectrum Analyzer FSE in conjunction 
with the optional Vector Signal Analyzer 
FSE-B7 is ideal for demodulating and 
measuring digitally modulated signals 
with frequencies up to 3.5 GHz, 7 GHz, 
26.5 GHz or 40 GHz. This universal tool 
offers a wide variety of settings: 

► Demodulation of all common 
mobile-radio signals 

► Freely selectable symbol rates 

► Type of filter 

► Roll-off factor or BT product of filter 

► Synchronization bit sequences 

► Predefined, application-specific set- 
tings for all conunon standards, e.g., 
GSM. PCS 1900, NADC, CDMA (IS95) 




Measurement of modulation error of 
pi/4-DQPSK signals (NADC). 



VERSATILE DISPLAY OF RESULTS 

► In-phase and quadrature signals 

► Magnitude and phase 

► Vector and constellation diagrams 

► Eye and trellis diagrams 

► Sum fault: amplitude, frequency, 
phase, vector 

POWER RAMP MEASUREMENTS 

To perform power ramp measurements 
on TDMA systems such as GSM or 
DECT in line with standards, reference 
must be made to synchronization 
sequences (pre- or mid-amble) in order 
to establish a time reference. Making 
such measurements to standard is not 
possible using conventional analyzers. 

ACCURATE AM, FM AND PHIM 
MEASUREMENTS 

Featuring high-accuracy measurement 
of the modulation depth and frequency 
deviation coupled with the display of 
demodulated signals in the time 
domain, FSE not only enables testing 
of analog and dual-mode radio equip- 
ment but also the determination of fast 
transient response in frequency and 
amplitude (see separate data sheet 
Vector Signal Analyzer FSE-B7, order 
number 757.2167). 

Spectrum Analyzer FSE and the option- 
al vector signal analyzer provide uni- 
versal test capabilities in one unit. 



www.tektronix.com/Measurement/conimtest/ 



SPECTRUM ANALYZERS 165 




Spectrum Analyzers 

FSEA20/30 • FSEB20/30 • FSEM20/30 • FSEK20/30 



Characteristics 



Specifications are guaranteed under the following conditions: 

30 minutes warm-up time at ambient temperature, specified environmental conditions met, calibration cycle adhered to and total calibration per- 
formed. Data without tolerances: typical values only. Data designated "nominal" apply to design parameters and are not tested. 





FSEA20 


FSEA30 


FSEB20 


FSEB30 


FSEM20 


FSEM30 


FSEK20 


FSEK30 


Freauencv-related** (Models .21/.31 : can be extended by ext. mixing) 


Frequency Range*’ 


9 kHz 
to 3.5 GHz 


20 Hz 
to 3.5 GHz 


9 kHz 
to 7 GHz 


20 Hz 
to 7 GHz 


9 kHz 

to 26.5 GHz 


20 Hz 

to 26.5 GHz 


9 kHz 
to 40 GHz 


20 Hz 
to 40 GHz 


Frequency Resolution 


0.01 Hz 


0.01 Hz 


0.01 Hz 


0.01 Hz 


0.01 Hz 


0.01 Hz 


0.01 Hz 


0.01 Hz 


Reference Frequency Internal (Nominal) 


Aging, per year*’ 


1 xl0-« 


2 X 10-7 


lxl0-« 


2 X 10-7 


1 xl0-« 


2 X 10-7 


1 xl0-« 


2 X 10-7 


Total error (per year) 


2.5 X 10-« 


2.5 X 10-7 


2.5 X 10-^ 


2.5 X 10-7 


2.5 X 10-^ 


2.5 X 10-7 


2.5 x 10-« 


2.5 X 10-7 


With Opt. FSEB4 


Aging, per year*’ 


2 X 10-7 


_ 


2x10-7 


- 


2 X 10-7 


- 


2 x 10-7 


- 


Total error (per year) 


2.5 X 10-7 


_ 


2.5 X 10-7 


- 


2.5 X 10-7 


- 


2.5 x 10-7 


- 


Frequency Counter 








Measures marker frequency 








Resolution 








0.1 Hz to 10 kHz (selectable) 








Count accuracy (S/N >25 dB) 






± (frequency x reference error 


+ 10 Hz + 1/2 (last digit)) 






Spectral Purity (dBc/Hz) - 

SSB phase noise, f <500 MHz 








for f >500 MHz see diagrams below 








Carrier offset 100 Hz*^ 


_ 


<-87 


- 


<-81 


- 


<-81 


- 


<-81 


Carrier offset 1 kHz*^ 


<-85 


<-107 


<-79 


<-100 


<-79 


-100 


<-79 


-100 


Carrier offset 10 kHz*^ 


<-95 


<-120 


<-90 


<-114 


<-90 


<-114 


<-90 


<-114 


Carrier offset 100 kHz*^ 


<-119 


<-117 


<-113 


<-111 


<-113 


<-111 


<-113 


<-111 


Carrier offset 1 MHz*^ 


<-135 


<-135 


-129 


-129 


<-129 


<-129 


<-129 


<-129 


With Opt FSEB4 For models .20 with Opt FSE-B4 values of models .30 apply 


Displayed Average Noise Floor (dBm) 




(0-dB RF attenuation, RBWIO Hz, VBWl Hz, 20 averages, trace average, span 0 Hz, termination 50 Q) 




Frequency 


20 Hz 




<-80 




<-74 




<-74 




<-74 


1 kHz 




<-110 




<-104 




<-104 




<-104 


10 kHz 


<-90 


<-125 


<-84 


<-119 


<-84 


<-119 


<-84 


<-119 


100 kHz 


<-110 


<-135 


<-104 


<-129 


<-104 


<-129 


<-104 


<-129 


1 MHz 


<-130, 


<-145, 


<-125, 


<-142, 


<-124, 


<-142, 


<-124, 


<-142, 




typ. -135 


typ. -150 


ty|X-130 


typ. -145 


typ. -129 


typ. -145 





typ. -145 


10 MHz to 3.5/6 GHz 


<-145, 


<-145, 


<-142, 


<-142, 


<-138, 


<-138, 


<-138, 


<-138, 




typ.-150 


typ. -150 


typ. <-147 


fyp- ^^7 


typ.-140 


typ. -140 


^.-140 


typ. -140 


6 GHz to 7 GHz 






<-139 


<-139 


<-135, 


<-135, 


<-135, 


<-135, 












typ. -138 


typ. -138 


typ. -138 


typ. -138 


7 GHz to 18 GHz 










<-138, 
typ. -140 


<-138, 
typ. -140 


<-134, 
typ. -139 


<-134, 

typ-'?? 


18 to 26.5 GHz 










<-135, 
typ. -138 


<-135, 

•ypr™ 


<-131, 


<-131, 
typ. -136 


26.5 GHz to 30 GHz 














<-120, 
typ. -125 


<-120, 
typ. -125 


30 GHz to 40 GHz 














<-116, 
typ. -122 


<-116, 
typ. -122 


Max. Dynamic Range 


10 Hz 
bandwidth 


1 Hz 

bandwidth 


to Hz 
bandwidth 


1 Hz 

bandwidth 


10 Hz 
bandwidth 


1 Hz 

bandwidth 


to Hz 
bandwidth 


1 Hz 

bandwidth 


Display noise floor to 
1 dB compression 


155 dB 


165 dB 


152 dB 


162 dB 


150 dB 


160 dB 


150 dB 


160 dB 


Max. Harmonics 
Suppres., f >50 MHz 


>90 dB 


>90 dB 


>90 dB 


>90 dB 


>90 dB 


>90 dB 


>90 dB 


>90 dB 


Max. Intermoduiation-free Range 


50 MHz to 3.5 GHz (nominal) 


105 dB 


115 dB 














150 MHz to 7/26.5 GHz (nominal) 






105 dB 


115 dB 


103 dB 


112 dB 


103 dB 


112 dB 



After 30 days operation. 

Models .20/. 21: valid for span <50 kHz, RBW <1 kHz. 
Valid for span >100 kHz. 



166 SPECTRUM ANALYZERS 



www.tektronix.com/Measuremeiit/comiiitest/ 




Spectrum Analyzers 

FSEA20/30 • FSEB20/30 • FSEM20/30 • FSEK20/30 





FSEA20 


FSEA30 


FSEB20 


FSEB30 


FSEM20 


FSEM30 


FSEK20 


FSEK30 


Intermodulation 


3rd-order intercept point 


>12 dBm, 


>12 dBm, 


>12 dBm, 


>12 dBm, 


>12 dBm, 


>12 dBm, 


>12 dBm, 


>12 dBm, 


(T.O.L), Af>5x 


typ. 15 dBm 


typ. 15 dBm 


typ. 15 dBm 


typ. 15 dBm 


typ. 15 dBm 


typ. 15 dBm 


typ. 15 dBm 


typ. 15 dBm 


resolution BW or >10 kHz 


for f >50 MHz 


for f >50 MHz 


for f >150 MHz 


for f >150 MHz 


forf >150 MHz 


forf >150 MHz 


for f >150 MHz; 


for f> 150 MHz; 
















>10 dBm for 


>10 dBm for 
















f>7GHz 


f>7 GHz 


Intermodulation-free range at -40 dBm mixer level 






105 dB 








Intercept point k2 (dBm) 


>25, typ. 


>25, typ. 


>25 for f 


>25 forf 


>25 for f 


>25 forf 


>25 forf 


>25 for f 




>40 for f 


>40 for f 


<150 MHz, 


<150 MHz, 


<150 MHz, 


<150 MHz, 


<150 MHz, 


<150 MHz, 




<50 MHz, 


<50 MHz, 


>35 typ. 


>35 typ. 


>35 typ. 


>35 typ. 


>40 for f 


>40 for f 




>45, typ. 


>45, typ. 


>40 for f 


>40 for f 


>40 for f 


>40 for f 


>150 MHz 


>150 MHz 




>50 for f 


>50 for f 


>150 MHz, 


>150 MHz, 


>150 MHz, 


>150 MHz, 








>50 MHz 


>50 MHz 


>45 typ. 


>45 typ. 


>45 typ. 


>45 typ. 






Immunity to Interference 


Image frequency (dB) 


>75 


>80, typ. >90 


>80, typ. >90 


>80, typ. >91 


>80, typ. >92 


>80, typ. >93 






Intermediate frequency (dB) 


>80 


>100 


>75 


>75 


>75 


>75 







Spurious response (f >1 MHz, without input signal, 0-dB attenuation) 



Span <30 MHz 


<-100 dBm 


<-110 dBm 


<-100 dBm 


<-110 dBm <-100 dBm 


<-110 dBm 


<-100 dBm 


<-110 dBm 


Span >30 MHz 








<-100 dBm 








fin = 25.175 MHz, 5.7172 GHz 








<-100 dBm 








fin = 60 MHz 


<-100 dBm 


<-110 dBm 


<-100 dBm 


<-100 dBm <-100 dBm 


<-100 dBm 


<-100 dBm 


<-100 dBm 



Other interfering signals <-80 dBm*^ <-80 dBm*^ <-75 dBm*^ <-75 dBm*^ <-75 dBm*^ <-75 dBm*^ <-75 dBm*^ <-75 dBm*^ 

(mixer level <-l0 dBm)*' 



Level Ptsp lay 



Measurement display 500 x 400 pixels (with one diagram displayed); max. 2 diagrams with independent settings 


Log level range 


10 dB to 200 dB (10 dB steps) 


Linear level range 


10% of reference level per division (10 divisions) or logarithmic scaling 


Trace 


Max. 4 traces with 1 diagram, 2 traces per diagram with 2 diagrams, 
simultaneous measurement with all traces 


Trace detector 


Max peak, min peak, auto peak (normal), sample, rms, average 


Trace functions 


Clear/write, max hold, min hold, average 


Setting range of reference level 


Log level display 


-130 dBm to 30 dBm, (0.1 dB steps) 


Linear level display 


7.0 nV to 7.07 V(l% steps) 


Units of level axis 


dBm, dBgV, dBmV, dBpA, dBpW (log and lin level display) mV, pV, mA, pA, pW, nW (linear level display) 


Level Measurement Error 


The values are guaranteed for bandwidths from 10 Hz to 30 kHz and 100 kHz to 10 MHz 


-40 dBm, RF attenuation 20 dB, ref. level 


-15 dB, RBW 5 kHz 


Absolute error at 120 MHz 


<0.3 dB 



Freq. Response (10 dB RF atten.) 

<1 GHz <0-5 dB 



1 G Hz to 3.5/7 GHz 5.LdB 



7 GHz to 18 GHz 










<2 dB*> 


<2 dB*' 


<2 dB*' 


<2 dB*' 


18 GHz to 26.5 GHz 










< 2.5 dB*' 


< 2.5 dB*' 


< 2.5 dB*' 


< 2.5 dB*' 


26.5 GHz to 40 GHz 














<3 dB*' 


<3 dB*' 


Attenuator error 


<0.3 dB 


<0.3 dB 


<0.3 dB 


<0.3 dB 


<0.3 dB 


<0.3 dB 


<0.3 dB 


<0.3 dB 



IF gain er ror __ „ dB, 0.1 dB typical 

Linearity Error 



Log level display 

(RBVV> 1 kHz, analog, S/N> 1 5dB) 



OdBto-50 dB 


<0.3 dB 


<0.3 dB 


<0.3 dB 


<0.3 dB 


<0.3 dB 


<0.3 dB 


<0.3 dB 


<0.3 dB 


-50 dB to -70 dB 


< 0.5 dB 


<0.5 dB 


<0.5 dB 


<0.5 dB 


<0.5 dB 


<0.5 dB 


<0.5 dB 


<0.5 dB 


-70 dB to -80 dB 


<1 dB 




<1 dB 




<ldB 




<ldB 




-70 dB to -95 dB 




<1 dB 




<1 dB 




<1 dB 




<1 dB 



Linear level display 

For inputs > 7 GHz: error after calling peaking function. For sweeptimes <10 mS/GHz, additional error 1.5 dB. 
Models .20/. 21: valid for span <50 kHz. RBW <1 kHz. 



www.tektronix.com/Measurement/commtest/ 



SPECTRUM ANALYZERS 167 



Spectrum Analyzers 

FSEA20/30 • FSEB20/30 • FSEM20/30 • FSEK20/30 





FSEA20 


FSEA30 


FSEB20 


FSEB30 FSEM20 


FSEM30 


FSEK20 


FSEK30 


Bandwidth Switching Error 


1 Hz to 30 kHz/100 to 300 kHz 








<0.2 dB/<0.2 dB 








1 MHz to 10 MHz 


<0.3 dB 


<0.3 dB 


<0.3 dB 


<0.3 dB <0.3 dB 


<0.3 dB 


<0.3 dB 


<0.3 dB 



DISPLAY RELATED 

Standard - 24-cm (9.5 in.) LC TF color dis- 
play. 

Resolution - 640 x 480 pixels (VGA resolution). 

Pixel Failure Rate - <2 x 10 ^ 

Mass Memory - 1.44-Mbyte 3.5 in. diskette 
(built-in disk drive), hard disk. 

ENVIRONMENTAL CHARACTERISTICS 
Operating Temperature Range - 

Nominal operating range: +5° C to +40° C. 
Limit operating range: +0° C to +50° C. 

Storage: -40° C to +70° C. 

Humidity - +40° C at 95% relative humidity 
(lEC 68-2-3). 

Mechanical Stress - 

Sinusoidal vibration: 5 to 150 Hz, max. 2 g at 
55 Hz; 0.5 g from 55 to 150 Hz; to lEC 68-2-6, 
lEC 68-2-3, lEC 1010-1, MIL-T-28800D, class 5. 
Random vibration: 10 to 300 Hz, acceleration 

L2 grms- 

Shock: 40 g shock spectrum, to MIL-STD-810C 
and MIL-T-28800D, classes 3 and 5. 
Recommended Calibration Interval - 1 year 
(2 years for operation with external reference). 
RFI Suppression - To EMC directive of 
ED (89/336/EEC) and German EMC legislation. 
Safety - To EN 61010-1, UL 3111-1, CSA C22.2 
No. 1010-1, lEC 1010-1. 

Test Mark - VDE, GS, UL, cUL. 

TV DEMODULATOR FSE-B3 

All specifications are nominal values. 

Video Output - 

Output voltage into 75 Q: 1 Vp.p. 

Video polarity: Positive/negative (standard 
switchable). 

Frequency response: 

0 to 4.43 MHz: -2 dB. 

Video S/N ratio (rms, to CCIR, level >3 mV): 

55 dB. 

Nonlinearity in case of 10% to 75% modulation: 
Differential gain: 10%. 

Differential phase: lO&deg. 

2-T-k factor: 3o/o. 

Triggering - 

TV trigger: V/H TV sync signals, any line within 
a 625- or 525-line system. 

Standards: B/G, D/K, I, L, M. 



168 SPECTRUM ANALYZERS 




FFT FILTER FSE-B5 

► High frequency resolution due to very small 
shape factor of 2.5 

► Extremely short measurement time, up to 
150 times faster than with conventional filters 

Resolution Bandwidths (RBW) - 

3 dB bandwidths, in 1/2/3/5 steps: 1 Hz to 1 kHz. 
Bandwidth error: 2%, nom. 

Shape factor 60:3 dB: 2.5, nom. 

Display Range for Frequency Axis - 

Min. span: 25 x RBW. 

Max. span: 100,000 x RBW, max. 2 MHz. 

Level Measurement Error - 

Additional total level error, referred to 
RBW 5 kHz: <1 dB. 

Max. Display Range - 100 dB. 

Immunity to Interference - 

Spurious response: <100 dBm. 




EXTERNAL MIXING FSE-B21 

LO Output/IF Input (Front Panel) - 

SMA female , 50 Q. 

LO signal: 7.5 GHz to 15.2 GHz. 

Amplitude: +15.5 dBm ±3 dB. 

IF signal: 741.4 MHz. 

Max. reference level: -20 dBm. 

IF Input (Front Panel) - SMA female , 50 Q. 
Frequency: 741.4 MHz. 

Max. reference level: -20 dBm. 




INCREASED LEVEL ACCURACY FSE-B22 
Total Level Error - 

<0.5 dB with 10 dB RF attenuation. 

<0.6 dB with 20/30/40 dB RF attenuation. 
Specifications Are Valid for - 
Temperature range: 20 to 30° C. 

Frequency range: 10 MHz to 2 GHz. 

Resolution bandwidths: 

5 to 30 kHz/300 kHz/1 MHz. 

Signal level: 

-10 dB to -50 dB below reference level. 

Stop frequency: <2 GHz. 

Sweep time: >3 x auto sweep time. 

BROADBAND OUTPUT 
741.4 MHZ FSE-B23 

FSE-B23 reduces the suppression of other 
interference signals to -50 dBm and must not 
be combined with FSE-K10/-K11. 

FSEA FSEB FSEM FSEK 

Gain from RF 
input to IF 

output (dB) 6 6 4 4 

3dBBW(MHz) 60 150 150*' 150*' 

40 to 40 to 

80 *^ 1 20 *^ 

f<7 GHz. 

7 GHz to 26.5 GHz. 

7 GHz to 40 GHz. 



www.tektronix.com/Measurement/commtest/ 




Spectrum Analyzers 

FSEA20/30 • FSEB20/30 • FSEM20/30 • FSEK20/30 



Power Requirements 


FSEA20 


FSEA30 


FSEB20 


FSEB30 


FSEM20 


FSEM30 


FSEK20 


FSEK30 


Power Supply 


AC supply 




200 V to 240 V: 50 Hz to 60 Hz, 100 V to 120 V: 50 Hz to 400 Hz, class of protection 1 to VDE 411 




Power consumption 


170 VA 


180 VA 


185 VA 


195 VA 


220 VA 


230 VA 


220 VA 


230 VA 


Dimensions in mm (W x H x D) 






435 X 236 X 460 (5 units of height) 




435 X 236 


435 X 236 


435 X 236 














x570 


x460 


X570 


Weight 


kg 


21.5 


22.7 


21.8 


23.2 


23.8 


25.2 


24.4 


25.8 


lb. 


47.3 


49.9 


48 


51 


52.4 


55.4 


53.7 


56.8 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see 



FSEA20 

9 kHz to 3.5 GHz Spectrum Analyzer. 

Includes: Power Cable, Operating Manual, 

Spare Fuses. 

FSEA30 

20 Hz to 3.5 GHz Spectrum Analyzer. 

Includes: Power Cable, Operating Manual, 

Spare Fuses. 

FSEB20 

9 kHz to 7 GHz Spectrum Analyzer. 

Includes: Power Cable, Operating Manual, 

Spare Fuses. 

FSEB30 

20 Hz to 7 GHz Spectrum Analyzer. 

Includes: Power Cable, Operating Manual, 

Spare Fuses. 

FSEM20 

9 kHz to 26.5 GHz Spectrum Analyzer. 

Includes: Power Cable, Operating Manual, Spare 
Fuses, Test Port Adapter 3.5-mm Female and N Female. 

FSEM30 

20 Hz to 26.5 GHz Spectrum Analyzer. 

Includes: Power Cable, Operating Manual, Spare 
Fuses, Test Port Adapter 3.5-mm Female and N Female. 

FSEK20 

9 kHz to 40 GHz Spectrum Analyzer. 

Includes: Power Cable, Operating Manual, Spare 
Fuses, Test-port Adapter K-Female, N-Female. 

FSEK30 

20 Hz to 40 GHz Spectrum Analyzer. 

Includes: Power Cable, Operating Manual, Spare 
Fuses, Test-port Adapter K-Female, N-Female. 

OPTIONS 

Opt. 02/B2 - 7 GHz Frequency Extension. 

Opt. B3 - TV Demodulator. 

Opt. 04/B4 - (FSEA20, FSEB20, FSEK20, FSEM 20) 
Low phase noise and OCXO. 

Opt. 07/B7 - Vector signal analyzer. 

Opt. 15/B15 - Controller with mouse and 
keyboard (English). 

www.tektronix.com/Measurement/commtest/ 



Opt. 16/B16 - Ethernet interface (15 contact ADI 
connector). 

Opt. XX - Ethernet interface, thin wire BNC connector. 
Opt. 17/B17 - Second lEC/IEEE-bus interface. 

Opt. 49 - Ethernet interface (BNC). 

Opt. B5 - (FSEA20, FSEB20, FSEK20, FSEM20 FFT 
Filter) 1 Hz-1 kHz. 

Opt. B8 - Tracking generator 3.5 GHz. 

Opt. B9 - Tracking generator 3.5 GHz with 
l/Q Modulator. 

Opt. BIO - FSE-BIO tracking generator 7 GHz. 

Opt. Bll - FSE-Bll tracking generator 7 GHz 
with l/Q Modulator. 

Opt. B12 - Switchable attenuator for tracking 
generator. 

Opt. B18 - Removable hard drive. 

Opt. B19 - Second hard drive (firmware included). 
Opt. B21 - External mixer. 

Opt. B22 - Increased level accuracy up to 2 GHz. 
Opt. B23 - Broadband output 741.4 MHz. 

MEASUREMENT SERVICE OPTIONS (FSEA 
20/30, FSEB 20/30, FSEM 20/30, FSEK 20/30) 
Opt. C3 - Three years of calibration services. 

Opt. D1 - Cal Data Report. 

Opt. D3 - Test data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover 
three years. 

SOFTWARE 

Noise Figure Measurement Software, 

Windows - Order FS-K3. 

Phase Noise Measurement Software - 

Order FSE-K4. 

GSM Application Firmware, Mobile - 

Order FSE-KIO. 

GSM Application Firmware, BTS - Order FSE-Kll. 
Service Kit - Extender boards and Coaxial Cables. 
Order FSE-Zl. 

FSE-KIO - GSM Application firmware mobile (good 
for all models; can be ordered as Opt. KIO). 

FSE-K11 - GSM Application firmware BTS (good for 
ail models can be ordered as Opt. Kll). 



the price list in the back of this catalog. 

Keyboard - American. Order PSA-Zl. 
lEC/IEEE-bus - 

1 m. Order 012-0991-01. 

2 m. Order 012-0991-00. 

19 in. Rack Adapter - With front handles, 

Order ZZA-95. Without front handles. Order ZZA-951. 
Set of Front Handles - Order ZZG-95. 

Transit Case - Order ZZK-954. (FSEM20, FSEK20). 
Order ZZK-955. 

Trolley - Order ZZK-1. 

Matching Pad - 75 Q, L Section. Order RAM. 
Matching Pad - 25 Q, Series Resistor. Order RAZ. 
Preamplifier - 

9 kHz to 30 MHz. Order ESH3-Z3. 

20 Hz to 1 GHz. Order ESV-Z3. 

DC Block - 

5 to 7000 MHz (Type N). Order FSE-Z3. 

10 kHz to 18 GHz (Type N). Order FSE-Z4. 

Microwave Measurement Cable and Adapter 

Set - For FSEM. Order FS-Z15. 

PS/2 Mouse - Order FSE-Z2. 

SWR Bridge - 

5 MHz to 3000 MHz. Order ZRB2. 

40 kHz to 4 GHz. Order ZRC. 

Attenuators - 

High Power 3/6/10/20/30 dB. 

100 W: Order RBUIOO. 

50 W: Order RBU50. 

Test-port Adapter - 

FSEM N (female). Order 1021.0535.00. 

3.5 mm (female), Order 1021.0512.00. 

FSEK: N (female), K (female)*’. 

Service Manual*’ 

Contact your local Tektronix representative 
for information. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

ROHDE& SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



SPECTRUM ANALYZERS 169 





3G Capable Spectrum Analyzers 

New R3267 • New R3273 




Features - Benefits 



Frequency Ranges: From 100 Hz to 
8 (R3267) or 26 (R3273) GHz to 
Cover Multiple Applications with 
One Unit 

High Dynamic Range: 137 dB 
(2 GHz band) to Perform 3 G 
Transmitter Measurements 

Excellent Signal Purity: <-l 10 dBc/Hz 
at 10 kHz Offset for Accurate 
Transmitter Characterizations 

Complete Demodulation Options: 
For Analysis of Transmitters in 
Frequency, Time, Phase and Code 
Domains 

High Measurement Throughput: 

20 Trace per Second Measurement 
Speed for Faster Testing Times on 
Production Lines 

Easy System Connectivity with 
Standard MS-DOS Floppy and GP-IB, 
Parallel, Serial and Color VGA Ports 



Applications 



1 G, 2 G and 3 G Transmitter 
Testing for Base Stations and 
Mobile Phones 

Digital Radio Manufacturing and 
System Tests 

Channel and Adjacent Channel 
Power Measurements of 
Transmitters 

Transmitter Modulation Quality 
Measurements 

Verifying Code Performance on 
CDMA and W-CDMA Systems 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916. 
inside the U.S. call: 
1-800-426-2200. 

C€ 

ilDVANTEST 

Advantest's quality ^em 
complies with the 
DIN ISO 9002 standard and 
has been certified by TUV 
Product Sen/Ice GMBH. 



Development of the latest communication tech- 
nologies, such as generation digital mobile 
systems (IMT-2000), requires a combination of 
spectrum and modulation measurement abili- 
ties. Furthermore, these new services must be 
introduced in less time and for more users than 
ever before. 

The R3267/3273 is a high-performance spectrum 
analyzer family designed to meet these needs for 
high throughput, wide bandwidth, high frequency 
and high quality digital modulation measurements. 

These instruments feature high dynamic range 
AGP measurement ability in addition to auto- 
mated occupied bandwidth, total power and 
average power measurement functions. 
Furthermore, the R3267 and the R3273 support 
optional modulation analysis for all common 
mobile communication standards. 



HIGH PERFORMANCE SPEaRUM ANALYZERS 

The R3267 and R3273 offer the necessary per- 
formance for a host of applications, from final sys- 
tem integration to production line or maintenance 
settings. This family boasts high signal purity and 
dynamic range (-110 dBc/Hz at 10 kHz offset and 
137 dB) as well as high throughput measurements 
(20 per second), high speed time domain analysis 
(1 ps), and 70 dB (typical at 5 MHz offsets) AGP 
measurements for W-GDMA. 

Such performance makes it ideal for next genera- 
tion mobile communication, satellite communi- 
cation and today’s diverse group of wireless 
communication system applications. 



170 SPECTRUM ANALYZERS 



www.tektronix.com/Measurement/commtest/ 





3G Capable Spectrum Analyzers 

NEW R3267 • NEW R3273 




OPTIONAL MODULATION ANALYSIS 
FOR NEXT-GENERATION DIGITAL 
MOBILE COMMUNICATION 

The R3267 and R3273 also provide 
optional modulation analysis for the 
proposed 3 G W-CDMA communication 
standard. Both general modulation 
accuracy measurements as well as code 
domain power measurements, essential 
for W-CDMA analysis are possible. 

Furthermore, base band signal analysis 
is made simple with built-in I/Q 
inputs. Finally, the R3267 and R3273 
also support modulation analysis 
options for CDMAOne, PDC, PHS, 
IS-136, GSM and DECT — meaning one 
instrument meets today’s and tomor- 
row’s measurement needs. 

These options provide measurement 
results such as rho, EVM, time align- 
ment error and carrier feedthrough. 
Furthermore, results can be displayed 
numerically or in a variety of graphical 
formats including constellation dia- 
grams. code domain, eye diagrams, 
power-time templates, demodulated 
data bits and plots of key modulation 
parameters over time. 

The demodulation ability of the R3267 
and R3273 is designed to give you only 
the capabilities that you need. Option 
01 adds the basic capability; individual 
standards can then be ordered as 
required. Further, multiple standards 
can be loaded into the instrument 
simultaneously for greater flexibility. 



HIGH SPEED AND HIGH 
THROUGHPUT 

The R3267 and R3273 have been opti- 
mized for speed to enhance measure- 
ment performance on manufacturing 
lines. These instruments can provide as 
many as twenty 1000 point trace 
updates in one second. In addition, the 
GPIB speed has also been improved 
over previous instruments to remove 
testing time as a production bottleneck. 

SIMPLIFIED STANDARD COMPLIANCE 

The R3267 and R3273 are ideal choices 
for final system development, integra- 
tion and manufacturing test of mobile 
radio transmitters. These instruments 
offer a host of automated measurements 
to make testing a transmitter’s perform- 
ance to a specification easy. The modu- 
lation analysis options provide standard 
templates with pass/fail prompts. The 
R3267 and R3273 also feature standard 
adjacent channel power, occupied band- 
width. channel power and spurious 
search measurements for a complete 
spectral evaluation of a transmitter. 

EASY CONNECTIVITY 

The standard GPIB. RS-232 and parallel 
ports ease the complexity of working 
with existing PC-based systems. 
Furthermore, the MS-DOS floppy 
allows you to quickly save setups, 
instrument traces, data results or even 
.BMP files of screen images. These 
images or ASCII data files can then be 
read by any of a number of standard, 
Windows-compatible programs. Finally, 
the TFT color LCD is VGA compatible 
and an external monitor port allows the 
screen image to be projected for presen- 
tations or viewed on standard computer 
monitors. 



thu My tJ 1J:Z3 



db 

TO 




PoMT M Tim 


i DM-rt .39 A j 


-2Q 


1 


Tv,.rra- — 1 , Mto UmI 




, j ^ ' 'M . 

! ^ 1 ' I^laU 




■ rf 


PASS 


TT 1 




-20 0 TO ■¥> 


GO 


100 120 lao tbo luo 

ftip 




Rm> lip 




Rmi> Dim, ^ IdB/dlwJ 






- - i . . 


-ZO 


/'V \ 


‘^1 


■ : w-tM 


1 ’ 


\ SatM 


•<iO 


... 1 . , 


1 


-100 




V^... -/i IlM, 

on- 


•2 2 l> 10 

Syobol 


14 


154 158 162 166 170 

Syi*al 




Characteristics 



FREQUENCY 

R3267 Frequency Range - 100 Hz to 8 GHz. 



Frequency 


Frequency 

Band 


Harmonic 
Order N 


100 Hz to 3.6 GHz 


0 


1 


1.6 GHz to 3.6 GHz 


1 


1 


1.6 GHz to 7 GHz 


2 


1 


6.9 GHz to 8 GHz 


3 


1 


Built-in YIG tuning pre-selector at 1.6 GHz to 
8 GHz. 

R3273 Frequency Range - 

100 Hz to 26.5 GHz. 


18 GHz - 60 GHz (with external mixer synchro- 
nization up to 325 GHz). 


Frequency 


Frequency 

Band 


Harmonic 
Order N 


100 Hz to 3.5 GHz 


0 


1 


3.5 GHz to 7.5 GHz 


1 


1 


7.4 GHz to 15.4 GHz 


2 


2 


15.2 GHz to 26.5 GHz 


3 


4 



Built-in YIG tuning pre-selector at 3.5 GHz to 
26.5 GHz. 

Frequency Reading Accuracy - ± (Frequency 
reading x Frequency reference accuracy + Span 
X Span accuracy + 0.15 x Resolution bandwidth 
+ 10 Hz). 

Marker Frequency Counter - 

(SPAN<1 GHz). 

Resolution - 1 Hz to 1 kHz. 

Accuracy(S/N > 25 dB) - ±(Marker 
frequency x Frequency reference accuracy 
+5 Hz X N + 1 LSD). 

Delta Counter - ±(A Frequency x Frequency 
reference accuracy + 10 Hz x N + 2 LSD). 



www.teMranix.coin/Measureinent/conimtest/ 



SPECTRUM ANALYZERS 171 








3G Capable Spectrum Analyzers 

NEW R3267 • NEW R3273 



Frequency Reference Accuracy - 

±3 X 10‘7day. 

±1 X lO'Vyear. 

±5 X lO'Vday (Opt. 21). 
±8xlO‘Vyear (Opt. 21). 



Frequency Stability - 

Residual FM; <3 Hz x N p-p/0.1 sec. 
Drift; Same as reference source. 


Signal purity 


f<2.6 GHz 


1 kHz 


-100 dBc/Hz 


10 kHz 


-llOdBc/Hz 


100 kHz 


-118dBc/Hz 



Frequency Span - 

Range: 

R3267: 0, 200 Hz to 8 GHz. 

R3273: 0, 200 Hz to 26.5 GHz. 

Accuracy: 

R3267: ± 1%. 

R3273: ± 1%. 

Resolution Bandwidth (3 dB) - 

Range : 10 Hz to 3 MHz, 5 MHz, 10 MHz (1, 3, 
10 sequences). 

Accuracy: 

±150/0 (RBW=100 Hz to 1 MHz). 

±250/0 (RBW=30 Hz, 3 MHz, 5 MHz). 

Video Bandwidth - 

Range: 1 Hz to 3 MHz, 5 MHz, 10 MHz (1, 3, 10 
sequences). 

Frequency Sweep - 

Sweep time: 

Zero span: 1 ps to 1000 s. 

Span > 200 Hz: 20 ms to 1000 s. 

Accuracy: ±3o/o. 

Trigger: Free-run, line, single, video, external, IF. 

AMPLITUDE RANGE 

Measurement Range - +30 dBm to Average 

noise level. 

Maximum Safe Input - 

Average continuous power: 

(Input ATT>10 dB): +30 dBm (1 W). 

DC input : 0 V. 

Display Range - 10 x 10 div. 

Log: 10, 5, 2, 1, 0.5 dB/div. 

Linear: 10% of reference level/div. 

Reference Level Range - 

Log: -140 dBm to +60 dBm (in 0.1 dB steps). 
Linear: 22.4 nV to 223 V (steps of 1% of 
full scale). 

Input Attenuation Range - 

R3267: 0 to 75 dB (5 dB steps). 

R3273: 0 to 70 dB (10 dB steps). 



DYNAMIC RANGE 

Average Noise Level - (100 Hz resolution 
bandwidth, 0 dB input attenuation, 1 Hz video 
bandwidth): 

R3267 

Frequency Frequency Average 
Band Noise Level 



1 kHz 


0 


-90 dBm 


10 kHz 


0 


-100 dBm 


100 kHz 


0 


-101 dBm 


1 MHz 


0 


-125 dBm 


10 MHz to 3.6 GHz 


0 


-(130 -f (GHz)) dBm 


1.6 GHz to 3.6 GHz 


1 


-125 dBm 


3.5 GHz to 7.0 GHz 


2 


-125 dBm 


6.9 GHz to 8.0 GHz 


3 


-125 dBm 


R3273 


Frequency Frequency 

Band 


Average 
Noise Level 


1 kHz 


0 


-90 dBm 


10 kHz 


0 


-100 dBm 


100 kHz 


0 


-101 dBm 


1 MHz 


0 


-125 dBm 


10 MHz to 3.6 GHz 


0 


-(130 - f (GHz)) dBm 


3.5 GHz to 7.5 GHz 


1 


-125 dBm 


7.4 GHz to 15.4 GHz 


2 


-122 dBm 


15.2 GHz to 26.5 GHz 


3 


-117 dBm 



1 dB gain compression: 0 dBm. 



SPURIOUS RESPONSE 
2nd Order 



Harmonic 

Distortion 


Frequency 

Range 


Mixer 

Level 


R3267 


<-70 dBc 


10 MHz to 3.5 GHz 


-30 dBm 


<-90 dBc 


>1.6 GHz 


-10 dBm_ 


R3273 


<-70 dBc 


10 MHz to 3.6 GHz 


-30 dBm 


<-100 dBc 


>3.5 GHz 


-10 dBm 


2 Signal 3rd Order 




Harmonic 


Frequency 


Mixer 


Distortion 




Level 



R3267 



<-80 dBc 


100 MHz to 3.5 GHz 


-30 dBm 


<-90 dBc 


>1.6 GHz 


-30 dBm 


R3273 


<-80 dBc 


100 MHz to 3.5 GHz 


-30 dBm 


<-70 dBc 


>3.5 GHz 


-30 dBm 



Residual Response (no input, input ATT 0 dB, 50 U 
termination) 



R3267 


<-100 dBm 


1 MHz to 3.5 GHz 




<-90 dBm 


300 kHz to 8 GHz 




R3273 


<-100 dBm 


1 MHz to 3.5 GHz 




<-90 dBm 


300 kHz to 26.5 GHz 





AMPLITUDE ACCURACY 
In-band Flatness Frequency Response 



R3267 


±1.5 dB 


100 Hz to 3.5 GHz 




±1.0 dB 


50 MHz to 2.6 GHz 




±1.5 dB 


1.6 GHz to 3.6 GHz 




±1.5 dB 


3.5 GHz to 7.0 GHz 




±1.5 dB 


6.9 GHz to 8.0 GHz 




R3273 


±1.5 dB 


100 Hz to 3.5 GHz 




±1.0 dB 


50 MHz to 2.6 GHz 




±l-5dB 


3.5 GHz to 7.5 GHz 




±3.5 dB 


7.4 GHz to 15.4 GHz 




±4.0 dB 


15.4 GHz to 26.5 GHz 





Calibration Signal Accuracy (30 MHz) - 

-10 dBm ±0.3 dB. 

IF Gain Error 

("after" automatic calibration)- 

0 dBm to -50 dBm ±0.5 dB. 

0 dBm to -80 dBm ±0.7 dB. 

Scale Display Accuracy 
(after automatic calibration) - 

Log: 

±0.2 dB/1 dB. 

±1 dB/lOdB. 

±1.5 dB/90 dB. 

Linear: ±5% of reference level. 

Input Attenuation Switching Error (in ref- 
erence to 10 dB, at 20 dB to 70 dB) - 



R3267 


100 Hz 
to 8 GHz 


±1.1 dB/10 dB steps. 
2.0 dB max. 


R3273 


100 Hz 


±1.1 dB/10 dB steps, 




to 12.4 GHz 


2.0 dB max. 




12.4 GHz 


±1.3 dB/10 dB steps. 




to 18 GHz 


2.5 dB max. 




18 GHz 


±1.8 dB/10 dB steps. 




to 26.5 GHz 


3.5 dB max. 



Resolution Bandwidth Switching Error - 

Resolution bandwidth in reference to 300 kHz, 
after automatic calibration: <±0.3 dB. 



ANALOG DEMODULATION (OPTION) 
Spectrum Demodulation - 

Modulation type: AM, FM. 

Audio output: Internal speaker, earphone jack, 
volume control possible. 

Continuous demodulation time: 100 ms to 1000 s. 



172 SPECTRUM ANALYZERS 



www.tektronix.com/ Measurement/ commtest/ 



Analyzers 



3G Capable Spectrum 

NEW R3267 • NEW R3273 



INPUT AND OUTPUT 
RF Input - 

Connector: N-type female (can be converted to 
SMA on R3273). 

Impedance: 50 Q. (nominal). 

VSWR (Input AT7>10 dB): 

<1.5:1 (<3.6 GHz) (nominal). 

<2.1:1 (>3.6 GHz) (nominal). 

Calibration Signai Output - 
Connector: BNC female, front panel. 
Impedance: 50 Q. (nominal). 

Amplitude: -10 dBm ± 0.3 dB. 

10 MHz Frequency Reference Output - 
Connector: BNC female, rear panel. 

Output impedance: 50 Q (nominal). 

Output amplitude range: -5 dBm to +5 dBm. 



10 MHz Frequency Reference input - 

Connector: BNC female, rear panel. 

Input impedance: 50 Q (nominal). 

Input amplitude range: -5 dBm to +5 dBm. 

Probe Power Supply - ±12.6 V (100 mA). 
Video Output - 

Connector: VGA (15-Pin, female), rear panel. 
640 X 480 dots (equivalent to VGA). 
Externai Trigger/Gate Input - 
Connector: BNC female, rear panel. 
Impedance: 10 kQ (nominal), DC coupled. 
Trigger level: TTL. 

Trigger Output - 

Connector: BNC female, rear panel. 

Amplitude: TTL level. 



Audio Output (demoduiation audio, 
option) - 

Connector: Small-type monophonic jack, front 
panel. 

Power output: 0.2 W max, 8 Q (nominal). 

I/O Interface - 

GPIB: IEEE-488 bus connector, rear panel. 
RS232: D-SUB 9-Pin, rear panel. 

Printer: D-SUB 25-Pin, rear panel. 

Extended I/O port: D-SUB 25-Pin, rear panel. 
FDD: 3.5 In. floppy disk drive. 

Safety - UL311M, CSAIOIO.I, EN61010-1, 
IEC61010-1. 



Ordering Information 



For price information: Outside the U.S. contact 

R3267 

Spectrum Analyzer. 

Includes: 

Power Cord, Manuals, Hard Front Cover. 

R3273 

Spectrum Analyzer. 

Includes: 

Power Cord, Manuals, Hard Front Cover. 

OPTIONS 

Opt. 01 - Digital Modulation Analysis. 

Opt. 02 - Memory Card (replacing the 
Floppy Drive). 

Opt. 05 - Audio Demodulation Output Option 
(AM, FM). 

Opt. 10 - Level Tuning Option (for PDC-BS). 

Opt. 16 - External Mixer Option (26.5 to 40 GHz, for 
R3273 only). 



your local Tektronix representative, inside the U.S. see 

Opt. 17 - External Mixer Option (40 to 60 GHz, for 
R3273 only). 

Opt. 21 - High-Stability Frequency Reference Source 
Option (±5 X lO'Vday). 

Opt. 61 - cdmaOne Analysis Software*^ 

Opt. 62 - W-CDMA Analysis Software*'. 

Opt. 63 - GSM/DECT Analysis Software*'. 

Opt. 64 - PDC/PHS/IS-136 Analysis Software*'. 

Opt. 73 - FM Deviation Analysis Software*'. 

Opt. 74 - Tracking Generator Option (with attenuator). 
Opt. 79 - Tracking Generator Option (without 
attenuator). 

*' Requires digital modulation analysis option (Opt. 01). 

ADDITIONAL ACCESSORIES 
Soft Case - Order R16219. 

Transit Case - Order R 16074. 



the price list in the hack of this catalog. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

Product(s) available through your local Tektronix 
Distributor listed in the back of this catalog. 

C€ 

ilDVANTEST 

Advantest's quality system complies with the 

DIN ISO 9002 standard and has been certified by TUV 

Product Sen/ice GMBH. 



www.tektronix.com/Measurement/commtest/ 



SPECTRUM ANALYZERS 173 





Spectrum Analyzer 

R3272 




Features - Benefits 



Frequency Range: 9 kHz to 26.5 GHz 

Compact and Lightweight - 
16.5 kg (36.3 lb.) 

Large TFT Color Liquid Crystal 
Display with VGA Output 

Delayed and Gated Sweep 

Highly Reliable, Narrowband Sweep 
Capability Based on Direct Digital 
Synthesizer Technology 
GPIB, RS-232 and Centronics 
Interfaces 

Two PCMCIA Memory Card Slots 



Applications 



Manufacturing, Installation and 
Maintenance of Microwave Point- 
to-Point Links 

PCS Microwave Link Measurement 

Satellite Link Manufacturing, 
Installation and Maintenance 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916. 
inside the U.S. call: 
1-800-426-2200. 




Product(s) complies with IEEE 
Standard 488.2-1987. 

ilDVANTEST 

Advantest's quality ^tem 
complies with the 
DIN ISO 9002 standard and 
has been certified by TUV 
Product Senrice GMBH. 



SPECTRUM 



LIGHTWEIGHT MICROWAVE 
SPEaRUM ANALYZER 

Today’s advanced information society is driven 
and supported by radio communications technol- 
ogy in which microwave and submillimeter wave 
communications are playing an increasingly 
important role. 

The R3272 spectrum analyzer allows engineers to 
easily and quickly perform spectrum analysis of 
microwave and submillimeter wave bands. This 
high performance, portable spectrum analyzer cov- 
ers a frequency range between 9 kHz and 26.5 GHz 
(up to 325 GHz using an external mixer) with an 
input range between +30 dBm and -120 dBm. an 
amplitude display dynamic range of 100 dB, and a 
resolution bandwidth of 300 Hz. In addition to 
these standard capabilities, the R3272 offers a 1 Hz 
resolution frequency counter. 

The R3272 is optimized for radio and spurious 
measurements for microwave and satellite com- 
munication. 

PORTABILITY ASSURES MOBILITY 

The R3272 is designed to assure maximum 
mobility. A robust design, conforming to MIL 
standards that demand high tolerance to vibra- 
tion and accidental drops, is impeccably housed 
within a compact package. 

ANALYZERS 



USER-FRIENDLY PANEL DESIGN 

The R3272 uses a TFT color LCD to provide a 
clear and accurate display of an array of data and 
information. The panel includes independent 
function keys, such as Occupied Bandwidth, 
Adjacent Channel Power, and Harmonic, for auto- 
matically locating Harmonics of a given signal. It 
also includes frequently used parameter setting 
keys for Bandwidth, Attenuation, and Sweeptime. 
Results are easily stored and accessed on MS-DOS 
compatible PCMCIA memory cards. 



Characteristics 



MEASUREMENT FUNaiON 
CW Mode - Spectrum measurement, power measure- 
ment, counter, spurious, OBW/ACP/HARM measurement. 

FREQUENCY 
Frequency Range - 

Standard: 9 kHz to 26.5 GHz. 

With external mixer: 18 GHz to 325 MHz. 

Frequency Reference Accuracy - 

±2x 10-®/day, ±1 X lO'Vyear. 

Resolution Bandwidth (3 dB) - 

Range (1, 3, 10 sequence): 

300 Hz to 3 MHz, 5 MHz. 



174 



www.tektronix.com/Measurement/commtest/ 








Spectrum Analyzer 

R3272 



Video Bandwidth Range - Range (1, 3, 10 
sequence): 1 Hz to 3 MHz, 5 MHz. 

Frequency Span - 

Linear span (zero span): 2 kHz to 26.5 GHz. 

DISPLAYED AVERAGE NOISE LEVEL 
(Resolution Bandwidth 1 kHz, Input 
Attenuator 0 dB, Video Bandwidth 1 Hz) - 
Frequency Range Frequency Displayed Average 



Band (N) Noise Level 



10 kHz 


1 


-70 dBm 


100 kHz 


1 


-80 dBm 


1 MHz to 3.1 GHz 


1 


-(115- 1.55 X 
f(CHz)) dBm 


3.0 to 7.5 GHz 


1 


-110 dBm 


7.4 to 15.4 GHz 


2 


-103dBm 


15.2 to 23.3 GHz 


3 


-96 dBm 


23.0 to 26.5 GHz 


4 


-90 dBm 


AMPLITUDE ACCURACY 




Frequency Response - 10 dB input 


attenuation: 

Frequency 


In Band 


Flatness 


Range 


Flatness 


Band (N) 


9 kHz to 3.1 GHz 


±1.5 dB 


1 


50 MHz to 3.1 GHz 


±1.0 dB 


1 


3 to 7.5 GHz 


±1.5 dB 


1 


7.4 to 15.4 GHz 


±3.5dB 


2 


15.4 to 23.3 GHz 


±4.0 dB 


3 


23 to 26.5 GHz 


±4.0 dB 


4 


Amplitude Range 


- +30 dBm to noise level. 



DISPLAY RANGE 
10 X 10 Divisions - 

Log: 10, 5, 2, 1, 0.5 dB/div. 

Linear: 10% of reference level/div. 

SWEEP 

Sweep Time - 50 ms to 1000 s. 

Sweep Trigger - Free, run, line, single, video, 
external. 

ANALOG DEMODULATION 
Spectrum Demodulation - 

Modulation type: AM, FM. 

Audio output: Speaker and phone jack with 
volume control. 

Marker pause time: 100 ms to 1000 s. 

CALIBRATOR 
Accuracy - -10 dBm ±0.3 dB. 

INPUTS AND OUTPUTS 
Front Panel - 

1st LO output: Connector type: SMA female; 
Impedance: 50 Q, nominal; Frequency range: 
3.421 to 7.921 GHz Amplitude: >+5 dBm. 
Memory card: Two 1C memory card slots. 

Rear Panel - 

GPIB: IEEE 488 bus connector. 

Centronics: D-Sub 25-Pin. 

RS 232 connector, VGA connector. 



ENVIRONMENTAL CHARAaERISTICS 
Operating Temperature - 0 to 50° C. 
Non-operating Temperature - -20 to 60° C. 
Humidity - <85% relative humidity. 

POWER REQUIREMENTS 

AC Line - 90 V to 132 V or 198 V to 250 V, 

auto-switching. 

Line Frequency - 48 to 66 Hz. 

Power Consumption - <300 V A. 

Physical Characteristics 

Dimensions (without handle, feet, and front cover) 



in. 



Width 


350 


13.8 


Height 


178 


7 


Depth 


420 


16.5 


Weight 


i« 


lb. 


Net 


15 


33 



your local Tektronix representative, inside the II.S. see 



Ordering Information 



For price information: Outside the U.S. contact 

R3272 

9 kHz to 26.5 GHz Portable Spectrum Analyzer. 
Includes: Power Cable, Input Cable, Connector 
Adapter, 6.3 A Power Fuse. 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of Calibration Services. 

Opt. D3 - Test Data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover 
three years. 



www.tektronix.com/Measurement/commtest/ 



RECOMMENDED ACCESSORIES 
Memory Card - 64 KB card. Order A09507 
Cart - Order K420. 

PROBES 

FET Probe - DC to 900 MHz (Requires 1101 A). 
Order P6201. 

FET Probe - DC to 500 MHz. Order P6202A. 

50 Q Divider Probe - DC to 3.5 GHz 6 ft. Order 
P6158. 

Current Probe - 935 Hz to 120 MHz. Order P6022. 



the price list in the back of this catalog. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 



Product(s) complies with IEEE Standard 488.2. 

ilDVANTEST 

Advantest's quality system complies with the 

DIN ISO 9002 standard and has been certified by TUV 

Product Service GMBH. 



SPECTRUM ANALYZERS 175 




Spectrum Analyzers 



R3465 



R3463 • R3263 




Features - Benefits 



R3465/R3463 

9 kHz to 8 GHz Frequency 
Coverage for Full Range of Digital 
Mobile Radio Frequencies 

One Button Measurements of 
Occupied Bandwidth, Adjacent 
Channel Power and Harmonics 

Options for Digital Radio 
Measurements Including GSM, PHS, 
PDC, NADC and CDMA 

Lightweight Portable - 
16 kg (35.2 lbs.) 

Automated CDMA BTS Transmitter 
Performance Checks with R34-AR 
Software 



Applications 



Digital Mobile Radio Transmitter 
Measurements of Spectrum, Time, 
and Modulation Characteristics 

CDMA Base Station Field and 
Manufacturing Test (Opt. 61) R34-AR 

NADC, PDC, PHS Mobile and Base 
Station Measurements 
(R3465/R3463) 

GSM Mobile and Base Station 
Measurements (Opt. 56 or 51) 

CDMA Mobile Phone 
Measurements (Opt. 61) 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 



Product(s) complies with 
IEEE Standard 488.2 

ilDVANTEST 

Advantest's quality ^em 
complies with the 
DIN ISO 9002 standard and 
has been certified by TUV 
Product Service GMBH. 



R3263 

Same Features as R3463 except: 
-GSM Measurement Option 
Available 

-Designed for General-Purpose 
Burst Envelope/Burst Spectrum 
Analysis 



R3465 8 GHz Modulation 
Spectrum Analyzer 

The R3465 is a high-performance spectrum ana- 
lyzer armed with capabilities sufficient to sup- 
port detailed waveform analysis. The high-speed 
settling synthesizer significantly reduces blank- 
ing time for narrow-band sweep (span of 5 MHz 
or less), thus enabling truly high-speed measure- 
ment. A high-frequency sweep accuracy of 1% 
or less, frequency stability of 2 x 10-» /day, and a 
built-in preselector starting from 1.7 GHz permit 
harmonic measurements with a dynamic range 
of 100 dBc. 

In addition to these powerful spectrum analyzer 
functions, the R3465 also offers built-in modula- 
tion analysis for a variety of digital mobile com- 
munication standards. Available options include 
measurement and graphics packages for CDMA, 
NADC/PDC/PHS, and GSM standards. For addi- 



tional flexibility, the R3465 allows any two of 
these modulation standards to be resident in the 
instrument at the same time. 

R3463 3 GHz Spectrum Analyzer 

The R3463 provides similar performance to the 
R3465 over a 9 kHz to 3 GHz range. This range is 
well suited for many digital radio measurements 
at an economical price. 

R3263 3 GHz Spectrum Analyzer 

The R3263 represents an economical solution for 
general-purpose burst signal analysis. The basic 
unit shares the spectrum analyzer characteristics 
of the R3463 along with spectrum due to modu- 
lation, spectrum due to switching, in-band spuri- 
ous, and zero-span burst envelope measure- 
ments. GSM measurement capability can be 
added with available options. 



176 SPECTRUM ANALYZERS 



www.tektronix.com/Measurement/commtest/ 





Spectrum Analyzers 

R3465 • R3463 • R3263 



One-button Measurements 

The R3465/R3463 allow one-button 
measurement of occupied bandwidth, 
adjacent channel leakage power, and 
harmonic signals. Assigning frequently 
used measurement functions to special 
function keys frees the user from repeti- 
tive panel operations. Measurements 
can be started by a simple one-key 
operation. The SINGLE key advances 
the measurement incrementally by each 
key stroke. The REPEAT key provides 
continuous measurements. 

Automatic Standard 
Parameter Settings 

Standard measurements of digital radio 
systems including PHS, PDC, NADC, 
CDMA, and GSM usually involve com- 
plicated parameter settings for each 
standard and measurement item. The 
R3465/R3463 has eliminated the bur- 
den for engineers by automating setting 
procedures, and one-touch settings of 
user-defined standards. 

Two PCMCIA Memory 

Card Slots 

Two memory card slots are provided to 
enable save/recall of system conditions 
as well as measurement results. On- 
screen displays can be saved in .BMP 
format for use in documentation. 

Easy-to-View Color Display 

A large, high-resolution, full-color TFT 
6.5 in. LCD display provides powerful 
support for multi-window operations. 
Optimum viewing is provided by a 
15-degree adjustable tilt mechanism. 

CDMA Modulation Analysis 
(with Opt. 6i) 

With addition of Opt. 61, the 
R3465/R3463 performs CDMA transmis- 
sion measurements in accordance with 
IS-95. This option provides cellular and 
PCS base/mobile station measurements 
in a single test set. In addition, the unit 
offers waveform quality analysis (rho) 
and code domain power measurements. 



www.tektronix.com/Measurement/commtest/ 



R34-AR CDMA Base Station 
Transmitter Autorun Software 

The Tektronix R34-AR autorun program 
simplifies CDMA Base Station transmit- 
ter measurements on the Advantest 
R3463 and R3465. The CDMA Tx 
Autorun program allows the user to 
configure the instrument for measure- 
ments in one, simplified menu screen. 
Another screen allows the user to define 
pass fail limits for all common CDMA 
transmitter measurements including 
rho. frequency error, error vector magni- 
tude, code domain performance, and 
channel power. The program automati- 
cally configures the instrument correctly 
for each measurement. 

Measurements can be run in either a 
single or repeat mode, with pass fail and 
numeric results shown on a summary 
screen. The repeat mode also tallies 
basic statistics, including maximum, 
minimum, and average recorded values 
over the length of the test. Result pages 
can be copied to printers, plotters, or 
PC compatible Flash Ram cards in 
.BMP format. 

The R34-AR program comes pre- 
installed on a Flash Ram card. This 
card also has sufficient memory space 
to allow for saving multiple measure- 
ment reports. 

NADC/PDC/PHS 

Modulation Analysis 

The R3465 and R3463 come standard 
with the ability to perform modulation 
analysis of NADC, PDC, and PHS sig- 
nals. Measurements such as phase error, 
magnitude error, error vector magnitude, 
and I/Q origin offset can be made at the 
push of a button. Additional options 
allow for graphical display of these 
measurements as well as a constellation 
diagram and demodulated data. 

GSM Modulation Analysis 

With the addition of the GSM transmis- 
sion options, the R3465 and R3263 can 
perform frequency error, phase error, 
and power vs. time measurements on 
GSM signals. Additional display 
options allow these results to be shown 
graphically, along with the demodulat- 
ed data and an FFT of the phase error. 



Characteristics 



Measurement Functions 

CW Mode - 

R3465/R3463: Spectrum, OBW, ACP, Harmonics. 
R3263: Spectrum. 

Transient Mode - 

R3465/R3463: Digital modulation analysis. 
R3263: Burst envelope, burst spectrum, GSM 
option. 

FREQUENCY RELATED 

R3465 - Frequency Range: 9 kHz to 8 GHz. 

Frequency Harmonic 

Band Order (N) 

9 kHz to 3.1 GHz 0 1 




1.7 GHz to 7.0 GHz 1 \ 

6.9 GHz to 8.0 GHz 2 

R3463/R3263 - 

Frequency Range: 9 kHz to 3 GHz. 

Frequency Harmonic 
Band Order (N) 

9 kHz to 3 GHz 0 1 



Frequency Readout Accuracy (Start, Stop, 
Center Frequency, Marker Frequency) - 

± (frequency reading x frequency reference 
accuracy + span x span accuracy + 0.15 x 
Resolution BW + 10 Hz). 

Frequency Reference Accuracy - 
±5 X 10“7day with Opt. 21 (R3465). 

±2 X 10“7day; ±1 x 10"Vyear. 

Frequency Stability - 

Residual FM (ZERO span): <3 Hz x N p-p/0.1 s. 

Drift after 1 hour warmup (Span <5 MHz): 

<20 Hz X Sweep Rate (minutes) x N. 

Signal Purity - 

10 kHz offset: <-100 dBc/Hz. 

100 kHz offset: <-110 dBc/Hz. 

Frequency Span - 
Linear Span Range: 

R3465: 9 kHz to 8 GHz, zero span. 
R3463/R3263: 9 kHz to 3 GHz, zero span. 
Accuracy: 

Span >5 MHz: ±4%. 

Span <5 MHz: ±1%. 

Resolution Bandwidth (3 dB) - 

Range (1, 3, 10 sequence): 

300 Hz to 3 MHz, 5 MHz. 

Video Bandwidth Range (1, 3, 10 
sequence) - 1 Hz to 3 MHz, 5 MHz. 
Frequency Sweep - 
Sweep time (CW mode. Spectrum 
Measurement): 50 ms to 1000 s. 

Accuracy; ±5%. 

Sweep Trigger: Free run. Line, Single, Video, 
External. 

Trace Speed: 10 times/second. 



SPECTRUM ANALYZERS 177 





Spectrum Analyzers 

R346$ • R3463 • R3263 



Gated Sweep (R3465/R3463)- 

Gate Position/Resolution; 

1 ^js to 65 ms in 1 \\s steps. 

Gate Width/Resolution: 

2 ps to 65 ms in 1 ps steps. 

Trigger: Internal IF detection, External. 

AMPLITUDE RELATED 
Measurement Range - +30 dBm to average 
display noise level. 

Maximum Safe Input Level - 

Average Continuous Power 

(input attenuation >10 dB): +30 dBm (1 W). 

DC Input: 0 V. 

Input Attenuator Range - 

0 to 70 dB in 10 dB steps. 

DYNAMIC RANGE 
Average Displayed Noise Level 
(RBW 1 kHz, Input Atten 0 dB, 

Video Bandwidth 1 Hz) - 

R3465 

Frequency Frequency Displayed 

Range Band Average Noise Level 



10 kHz 


0 


-70 dBm 


100 kHz 


0 


-80 dBm 


1 MHz 


0 


-(115- 1.55 xf 


to 3.0 GHz 




(GHz)) dBm 


1.7 GHz to 7.0 GHz 


1 


-115 dBm 


6.9 GHz to 8.0 GHz 


2 


-115 dBm 


R3463/R3263 




Frequency 


Frequency 


Displayed 


Range 


Band 


Average Noise Level 


10 kHz 


0 


-70 dBm 


100 kHz 


0 


-80 dBm 


1 MHz 


0 


-(115-1.55x1 


to 3.0 GHz 




(GHz)) dBm 


1.7 GHz 

to 3.0 GHz (R3463) 


1 


-115 dBm 



1 dB Gain Compression - >10 MHz, -5 dBm 
(input mixer level). 



AMPLITUDE ACCURACY 

Frequency Response (Input Atten 10 dB) - 



R3465 

Frequency 

Range 


Frequency 

Band 


In Band 
Flatness 


9 kHz to 3.0 GHz 


0 


±1.5 dB 


50 MHz to 3.0 GHz 


0 


±1.0 dB 


1.7 GHz to 7.0 GHz 


1 


±1.5 dB 


6.9 GHz to 8.0 GHz 


2 


±1.5 dB 


R3463/R3263 




Frequency 


Frequency 


In Band 


Range 


Band 


Flatness 


9 kHz to 3.0 GHz 


0 


±1.5 dB 


50 MHz to 3.0 GHz 


0 


±1.0 dB 



ANALOG DEMODULATION 
Spectrum Demodulation - 

Modulation Type: AM, FM. 

TIME DOMAIN MEASUREMENT 
(R3465/R3463) 

Amplitude Resolution - 12-Bits. 

Sweep Time - 50 ps to 2 s. 

Trigger - 

Free-run, Single, Video, IF detection, external. 

Delayed Trigger Time - 200 ns to 650 ns. 

INPUTS AND OUTPUTS 
RF Input - 

Connector: Type N female. 

Impedance: 50 Q. (nominal). 

Calibration Signal Output - 
Connector: BNC female, front panel. 

10 MHz Frequency Reference 
Input/Output - 

Connector: BNC female, rear panel. 

Output Impedance: 50 Q. (nominal). 

Video Output - 

Connector: VGA 15-Pin female, rear panel. 

X, Y and Z Axis Output - 

BNC female, rear panel. 



External Trigger Input - 

Connector: BNC female. 

Impedance: 10 kO. (nominal), DC coupled. 
Trigger Level: TTL level. 

Gate Input - 

Connector: BNC female, rear panel. 
Impedance: 10 kil (nominal). 

1 / 0 - 

GPIB: IEEE-488 bus connector. 

Parallel: D-SUB 25-Pln connector. 

RS 232: D-SUB 9-Pin connector. 

Direct File Output: 

Saves .BMP files to PCMCIA cards. 

Other - 

External Keyboard: DIN connector. 

Memory Card: Two memory card slots, front 
panel, JEIDA-Ver 4.2/PCMCIA2.1. 

CDMA Base Station Testing 

Refer to R3465/R3463 Opt. 61 and R3561L 
CDMA base station testers. 

Environmental 

Temperature - Operating: 0 to +50° C. 
Storage: -20°C to +60° C. 

Humidity - 85% relative humidity or less. 

Power Requirements 

Line Voltage - 

100 VAC/220 VAC, auto-switching. 

Voltage Range - 

100 V Operation: 100 V to 120 V. 

220 V Operation: 220 V to 240 V. 

Line Frequency - 50 Hz/60 Hz. 

Power Consumption - 300 VA. 

Physical Characteristics 

Dimensions (without handle, feet, front cover) 



mm in. 



Height 




177 


7 


Width 




350 


13..8 


Depth 




420 


16.5_ 


Weight 






lbs. 


Net 




17 _ 


37.5 



spectrum analyzers 



178 



www.tektronix.com/Measurement/commtest/ 



Spectrum Analyzers 

R3465 • R3463 • R3263 



R3465/R3463/R3263 Spectrum Analyzer 


Selection Guide by Communication Standard 


Standard 


R3465 - 9 kHz to 8 GHz 


R3463 - 9 kHz to 3 GHz 


R3263 - 9 kHz to 3 GHz 


GSM 


R3465 Opt. 56 (GSM Measurements only) 


N/A 


R3263 Opt. 55 (GSM measurements) 




R3465 Opt. 56 and 77 




R3263 Opt. 55 and 77 




(GSM measurements with graphics) 


N/A 


(GSM measurements with graphics) 


CDMA 


R3465 Opt 61 


R3463 Opt. 61 


N/A 




(CDMA measurements/constellation 


(CDMA measurements/constellation analysis 






analysis with graphics. 


with graphics. 






NADC measurements) 


NADC measurements) 






R3465 Opt. R3561L 


R3463 Opt. R3561L 


N/A 




Signal Generator (requires Opt. 61) 


Signal Generator (requires Opt. 61) 






for base station receiver testing 


for base station receiver testing 




NADC/PDC/PHS 


R3465 (standard). R3465 Opt. 76 


R3463 (standard). R3463 Opt. 76 


N/A 


(All NADC measurements 


(PDC/PHS/NADC measurements/ 


(PDC/PHS/NADC measurements/ 




include PDC and PHS) 


constellation analysis/graphics) 


constellation analysis/graphics) 




GSM + CDMA 


R3465 Opt. 56 and 61 


N/A 


N/A 




(GSM measurements, 








CDMA measurements/ 








constellation analysis with graphics) 








R3465 Opt. 56, 61, and 77 


N/A 


N/A 




(GSM measurements with 








graphics, CDMA measurements/ 








constellation analysis with graphics) 






GSM + NADC 


R3465 Opt. 51 


N/A 


N/A 




(GSM measurements with 








graphics, NADC measurements) 








R3465 Opt. 51 and 77 


N/A 


N/A 




(GSM measurements with 








graphics, NADC measurements) 








R3465 Opt 51, 76, and 77 


N/A 


N/A 




(GSM measurements with graphics. 








NADC measurements/constellation analysis/graphics) 






CDMA + NADC 


R3465 Opt. 61 


R3463 Opt. 61 


N/A 




(NADC measurements, CDMA measurements/ 


(NADC measurements, CDMA measurements/ 






constellation analysis with graphics) 


constellation analysis with graphics) 






R3465 Opt. 61 and 76 


R3463 Opt. 61 and 76 


N/A 




(NADC measurements/constellation 


(NADC measurements/constellation 






analysis with graphics, CDMA measurements/ 


analysis with graphics, CDMA measurements/ 






constellation analysis with graphics) 


constellation analysis with graphics) 






Ordering Information | 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



R3465 

8 GHz Modulation Spectrum Analyzer. 

R3463 

3 GHz Modulation Spectrum Analyzer. 

R3263 

3 GHz Burst Spectrum Analyzer. 

All include: Power Cord (A01412), Input Cable (MC- 
61), Conversion Adapter (JUG-201 A/U), 6.3 A Power 
Fuse (21806.3), Manual. 

R3465/R3463/R3263 OPTIONS 
Opt. 15 - Controller option for user-defined auto- 
mated routines. 

Opt. 21 - High stability reference (R3465). 

Opt. 51 - GSM measurements (R3465 only). 

Opt. 55 - GSM measurements (R3263 only). 

Opt. 56 - GSM measurements only (R3465 only). 
Opt. 61 - CDMA transmitter measurements (Code 
domain power, waveform quality, l/Q measure- 
ments), CDMA constellation analysis with graphics. 



Opt. 73 - FM Deviation Measurement. 

Opt. 76 - PDC/PHS/NADC Graphics (R3465/R3463). 
Opt. 77 - GSM Graphics (R3465/R3263). 

Opt. 1R - Rackmount. 

Opt. R3561L - Reverse link signal source for CDMA 
base station and mobile receiver simulation 
(R3465/R3463). Opt. 61 and 09 required. 

SOFTWARE 

R34-AR - CDMA Transmitter Test Autorun Software. 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - 3 years of Calibration Service. 

Opt. D3 “ Test Data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover 
three years. 

RECOMMENDED ACCESSORIES 

64 KB PCMCIA card. Order A09507. 

Memory Card - 256 KB PCMCIA card. 

Order A09508. 



PROBES 

FET Probe - DC to 900 MHz (Requires 1101 A). 
Order P6201. 

FET Probe - DC to 500 MHz. Order P6202A. 

50 Q Divider Probe - DC to 3.5 GHz, 6 ft. 

Order P6158. 

Current Probe - 935 Hz to 120 MHz. Order P6022. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916. inside the U.S. call: 1-800-426-2200. 



Product(s) complies with IEEE Standard 488.2. 

ilDVANTEST 

Advantesfs quality system complies with the 

DIN ISO 9002 standard and has been certified by TUV 

Product Sen/ice GMBH. 



www.tektronix.com/Measurement/commtest/ 



SPECTRUM ANALYZERS 179 






For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S, call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 

C€ 

ilDVANTEST 

Advantesfs quality system 
complies with the 
DIN ISO 9002 standard and 
has been certified by TUV 
Product Service GMBH. 



Features - Benefits Applications 



R3561 

High Waveform Quality for Module 
Testing Applications 

Built-in AWGN Source for 
Comprehensive Receiver Tests 

GPIB Interface as Standard 

Unit Can Be Controlled from a PC 
or from an R3463/65 with Opt. 61 

The R3561 Generates a BTS Signal 
Conforming to IS-97 with a 
Maximum of Three Code Channels 

Simulates Either Base or Mobile 
Station Signals 

Covers Both Cellular and PCS 
Systems 

R3561L 

One Unit Covers a Wide Frequency 
Band (for Cellular and PCS): 

50 MHz to 2 GHz (1 Hz resolution) 

High Waveform Quality: 0.96 for 
Accurate Measurements 

Detached, Portable Form Factor 
Means the Unit Only Has to Be 
Taken to a Site When Receiver 
Testing Is Necessary 

Modulated Signal Conforming to 
IS-95 

Delivers All Data Rates 

Tracking Generator Function for 
Antenna and Filter Testing 

Built-in AWGN Source 

All Functions Can Be Controlled 
from the R3465/3463 (Opt. 09 Is 
Necessary) 



R3561 

Production Testing of Base Station 

or Mobile Phone Receivers 

R3561L 

Base Station Installation and 

Mainframe Receiver Testing 

Manufacturing Test of Base Station 

Receivers 

Note 1: Rx control option (Opt. 08) 
requires adding the CDMA option 
(Opt. 61 ) to the R3465/3463 series 
modulation spectrum analyzer. 

Note 2: To add the Rx control option 
(Opt. 08) to your R3465/3463 series 
modulation spectrum analyzer after 
purchase and delivery, please contact 
your local Tektronix office. 



180 



CDMA RECEIVER 



www.tektronix.com/Measurement/commtest/ 





CDMA Receiver Test Sources 

R3561 • NEW 3561 L 



For both the R3561 and R3561L, the 
system under test must provide the 
resulting error rate from the test source 
signal. For further information, consult 
vendor documentation or contact your 
local Tektronix office. 

For Receiver Testing of 
CDMA (IS-95) Base/Mobile 
Stations 

R3561L CDIVIA TEST SOURCE UNIT 

The R3561L CDMA test source unit is 
used in combination with the 
R3465/3463 series modulation spec- 
trum analyzer. CDMA test source con- 
trol option (Opt. 09) is necessary for the 
R3465/3463. The R3561L outputs a 
modulated signal conforming to lS-95 
to test the receiver characteristics of the 
base station. One unit can be used for 
both cellular and PCS systems. 

R3561 CDMA Test Source 

The stand-alone R3561 series CDMA 
soiurce can be used to test base and 
mobile stations for both cellular and 
PCS CDMA systems. The R3561 gener- 
ates a base station signal conforming to 
IS-97 with a maximum of three code 
channels (Pilot, Sync and Traffic). The 
unit Ccm also generate a reverse traffic 
channel signal conforming to IS-98 for 
CDMA mobile stations. The R3561’s 
wide frequency range and excellent 
waveform quality means the instrument 
is useful in a host of applications, 
including manufacturing test of BTS 
and MS receivers, as well as testing of 
RF modules and subsystems. The R3561 
can be used with the R3463/3465, or 
independently through GPIB control. 




R3561 Series CDMA Test Source. 



1 Characteristics I 




R3561 


R3561L 


Output Frequency 


Range 


800 to 2300 MHz 


50 to 2000 MHz 


Resolution 


100 Hz 


1 Hz 


Accuracy 


Depends on 
the accuracy of 
reference source 


Depends on 
the accuracy of 
the R3465/3463 
reference source 


Output Level 


Range 


-125 dBm approximately 0 dBm 


Resolution 


0.1 dB 


0.1 dB 



MODULATION 

R3561 

Output Frequency - 

Range: 800 to 2300 MHz. 

Modulation Mode - OQPSK / QPSK 
(EIA/TIA/IS-95). 

Waveform Quality - >0.99 (after calibration). 

Channel Type - 

Forward Link: 

Channel (A): Pilot/Sync/Traffic. 

Channel (B): Pilol/Sync^raffic. 

Channel (C): Pilot. 

Reverse Link: Pilot (ZEROS)/Traffic. 

Variable Level Between Channels - 

Range: -5 to -30 dB (with respect to total 
level). 

Resolution: 0.1 dB. 

Accuracy: <± 0.5 dB. 



Transmission Rate - 

9600 bps/4800 bps/2400 bps/1200 bps. 

14400 bps/7200 bps/3600 bps/1800 bps. 

Data Source - 

PN 9/PN 15. 

USER 600 Frames (written by user via GPIB). 
PN Offset - 0 to 511 (x 64 chips). 

Long Code Mask - 42 ZEROS. 

External l/Q Input - DC to 2.5 MHz, 
Frequency characteristic < 2 dBp-p. 

R3561L 
Reverse Link - 

Modulation mode: QPSK (EIA/TIA/IS-95). 
Channel: Traffic channel. 

Data rate: 9600 bps/4800 bps/2400 bps. 

1200 bps, 14400 bps/7200 bps. 

3600 bps/1800 bps. 

Data source: ZEROS/RANDOM/RAND+ERR USER 
600 Frames (written by user via GPIB). 

Forward Link - 

Modulation mode: QPSK (EIA/TIA/IS-95). 
Channel: Pilot channel. 

Waveform Quality - >0.96. 

PN Offset - 0 to 511 (X 64 chips). 

Long Code Mask - 42 ZEROS. 

Burst ON/OFF Ratio - >20 dB. 

TRACKING GENERATOR FUNCTION 

R3561LONLY 

Output Frequency - 

Range: 50 to 2000 MHz. 

Resolution: 1 Hz. 

Accuracy: Depends on the accuracy of 
R3465/3463 reference source. 

Output Level - 
Range: -50 to 0 dBm. 

Resolution: 0.1 dB. 

Accuracy (25 ±10° C): ^1.5 dB (center fre- 
quency 1 GHz, zero span). 

Safety - UL3111-1, CSAIOIO.I, IEC61010-1. 




Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



R3561 

CDMA Test Source. 

R3561L 

CDMA Test Source. 



For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

Product(s) available through your local Tektronix 
Distributor listed in the back of this catalog. 



ce 

ilDVANTEST 

Advantesfs quality system complies with the 

DIN ISO 9002 standard and has been certified by TUV 

Product Service GMBH. 



www.tektronix.com/Measurement/commtest/ 



CDMA RECEIVER 181 












Spectrum Analyzer 

New U3661 




Features - Benefits 



LIGHTEST WEIGHT 26.5 GHZ 
MICROWAVE SPECTRUM ANA- 
LYZER WITH 100 HZ RBW 

Frequency Range: 9 kHz to 26.5 GHz 

Ultra-compact and Light Weight 
(Main Unit: 8.5 kg or Less; with 
Battery: 10.8 kg or Less) 

Display Dynamic Range: 100 dB 
Three-way Power Supply with 
Battery Operation 
-(100/200 VAC, external DC, and 
battery pack) 

TFT 6-inch Color LCD and Memory 
Card 

High-stability Measurement by 
Means of Synthesized Operation 
50-ps High-speed Sweep Function 

Diverse Options Including: 

-TV Video/Audio Demodulation 
-Tracking Generator 
-High-stability Reference Source 
-Narrow RBW 
-Channel Input Setting 
-CDMA Setting 



Applications 



Field Maintenance of Microwave 
Links 

Installation and Maintenance of 
Digital Radio Facilities 
TV/Broadcast Maintenance 
Measurement of ACP, OBW 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916. 
inside the U.S. call: 
1-800-426-2200. 

C€ 

ilDVANTEST 

Advantest's quality ^tem 
complies with the 
DIN ISO 9002 standard and 
has been certified by TUV 
Product Sen/ice GMBH. 



For Field Maintenance of 
Microwave Radio Facilities and 
Digital Mobile Communication 

The radio communication field is undergoing 
fast growth on a global scale, expanding the fre- 
quency band usage across the spectrum from the 
microwave to the millimeter-wave bands. The 
U3661, at 8.5 kg, is the lightest weight 
microwave spectrum analyzer in the world. 

It accommodates the diverse needs of these vari- 
ous communication systems. As well as 
enhanced basic performance as a spectrum ana- 
lyzer, the U3661 is equipped with many stan- 
dard functions such as power calculation and 
high-speed sweep. 



The compact, lightweight design of the U3661 
utilizes a three-way power source system which 
includes a battery; it is an optimum analyzer for 
field measurement. This unit also has a built-in 
RS232 interface for a personal computer, facili- 
tating flexible data management using standard 
memory cards. 

The U 3 661 is rugged enough to satisfy the 
requirements of vibration, shock and drop tests, 
allowing them to be used safely under harsh 
field conditions. 

April 1998. 



182 SPECTRUM ANALYZERS 



www.tektronix.com/Measurement/commtest/ 





Spectrum Analyzer 

NEW U3661 




2-SLOTS MEMORY CARD DRIVE 

Having two memory card drives con- 
forming to JEIDA-Ver. 4.1/PCMCIA 
Rel. 2.0 as standard, measurement con- 
dition setup, and data recording can be 
performed while two memory cards are 
loaded in the drives. There are three 
different record formats for memory 
card: binary, bitmap, and text (CSV). In 
particular, the text (CSV) format is 
handy for data analysis and report cre- 
ation using spreadsheet software on a 
personal computer. 

WIDE ARRAY OF ANALYSIS FUNCTIONS 

Along with basic functions such as a 
frequency counter with a 1 Hz resolu- 
tion and a 20 dB gain preamplifier, the 
U3661 comes standardly equipped with 
analysis functions for measuring items 
such as dB down, third order intermod- 
ulation distortion, AM modulation, 
occupied bandwidth, and adjacent 
channel leakage power. GO-NO GO 
evaluations of the displayed waveform 
can also be easily performed using the 
limit line and PASS/FAIL functions 
which allow upper and lower limits to 
be set on the screen. 



1 Characteristics 




FREQUENCY 

Frequency Range: 9 kHz to 26.5 GHz. 


Frequency 


Frequency 


Harmonic 




Band 


Order N 


9 kHz to 3.2 GHz 


0 


1 


3.0 GHz to 7.1 GHz 


1 


1 


6.7 GHz to 14.5 GHz 


2 


2 


13.7 GHz to 26.5 GHz 


4 


4 



Preamplifier: 9 kHz to 3.2 GHz (Band 0). 
Frequency Read Accuracy (Start, stop, center 
frequency, marker frequency): ± (Frequency 
reading x Frequency reference accuracy + 5% x 
Span + 15% X RBW + 60 Hz x N). 

Resolution Bandwidth (3 dB) - 
Range: 1 kHz to 3 MHz, 1 to 3 sequences. 

100 Hz, 300 Hz (with Opt. 26). 

Selectivity: <15: 1 (60 dB : 3 dB). 

Video Bandwidth: 10 Hz to 3 MHz, 

1 to 3 sequences. 



Dynamic range 

Average Display Noise Level - RBW 1 kHz, 
VBW 10 Hz, input attenuator 0 dB, frequency 
> 1 MHz. 

Preamplifier OFF - 

Frequenty Band Noise Level 



0 -{11 


l7-2f[GHz]) dBm_ 




1 


-105 dBm 




2 


-no dBm 




4 


-105 dBm 





Preamplifier ON - -132 dBm + 3 f[GHz] dBm 
(1 MHz to 3.2 GHz (Band 0)). 

IdB Gain Compression - Input attenuator 
0 dB, frequency 10 MHz or more. 

Preamplifier OFF: >-l0 dBm (mixer input level). 
Preamplifier ON: >-30 dBm (preamplifier 
input level). 

Spurious Response - Preamplifier OFF, input 
attenuator 0 dB. 

AMPLITUDE ACCURACY 

Frequency Response: Automatic calibration, 
after pre-selector peak execution. 

Preamplifier OFF: 100 kHz to 2.7 GHz; < ±1 dB. 
9 kHz to 3.2 GHz; < ±2 dB. 

3 GHz to 7 GHz; <±1.5 dB. 

7 GHz to 14.4 GHz; < ±3.5 dB. 

14.4 GHz to 26.5 GHz; < ±4.0 dB. 

Preamplifier ON: 100 kHz to 2.7 GHz; < ±1 dB. 
(Band 0) 9 kHz to 3.2 GHz; < ±2 dB. 



www.tektronix.com/Measurement/comintest/ 



SPECTRUM ANALYZERS 183 






Spectrum Analyzer 

NEW U3661 



DEMODULATION 
Audio Demodulation - 

Modulation Type; AM, FM (FM operates at 
RBW > 3 kHz). 

Audio Output: Speaker and earphone jacks 
(with volume control). 

INPUT/OUTPUT 
RF Input - 

Connector; Type N, female (or Type SMA). 
Impedance: 50 Q (nominal). 

VSWR Preamplifier OFF; Input attenuator 10 dB 
to 50 dB. 

<1.5:1 (100 kHz to 3 GHz). 

<2:1 (3 GHz to 26.5 GHz). 

VSWR Preamplifier ON (Band 0): <2.5:1 (9 kHz 
to 3.2 GHz). 



GENERAL SPECIFICATIONS 
Temperature - 

Operating Temperature; 0° C to 50° C 
Relative Humidity: 85% or less 
Storage Temperature: -20° C to 60° C 
Power Requirements - 
External DC Input; 70 W maximum. 
Connector: XLR 4 pins. 

Input Range: +10 V to +16 V. 

With AC Adapter; Automatic 100 V/200 VAC 
switching. 

100 VAC Operation: 

Voltage: 100 V to 120 V. 

Frequency: 50 Hz/60 Hz. 

220 VAC Operation; 

Voltage: 220 V to 240 V. 

Frequency; 50 Hz/60 Hz. 



Power Consumption - 

External DC Input: 70 W maximum. 

With AC Adapter; 120 VA maximum. 

Safety - UL3111-1, CSAIOIO.I, EN61010-1, 
IEC61010-1. 

Weight - 

Main Unit: 8.5 kg or less (accessories, carrying 
strap, and battery not included). 

AC/DC Adapter (A08364); 1.1 kg. 

Pro Pac 14 Battery : 2.3 kg. 

Dimensions - 

Approx. 148 mm (H) x Approx. 291 mm (W) x 
330 mm (D). (Stand, connectors and other pro- 
trusions not included). 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1 - 503 - 627 - 1916 , Inside the U.S. call: 1 - 800 - 426 - 2200 . 



U3661 

Spectrum Analyzer. 

OPTION GUIDE 

Opt. 20 - High-Stability Reference Source. High-sta- 
bility reference oscillator with an aging rate of 
± 2 X 10"7day. 

Opt. 26 - Narrow RBW. Adds 100 Hz and 300 Hz 
resolution bandwidths. 

Opt. 60 - CDMA Setting.* Allows channel power, 
ACP, OBW and spurious emission (in-band) meas- 
urement 

Opt. 72 - TV Demodulation* Frequency tuning func- 
tion by channel input, TV video/audio demodulation 
function. 

Opt. 74 - Tracking Generator. Filter evaluation func- 
tion/LOSS measurement function for the frequency 
range from 100 kHz to 2.2 GHz. 

Opt. 78 - Channel Input Setting.* VHF, UHF, CATV, 
BS, CS channels of various countries and user chan- 
nel can be set. 



ACCESSORIES 

OPTIONS (SOLD SEPARATELY) 

Opt. 3661 + 20 - High-Stability reference option. 
Opt. 3661 + 26 - Narrow RBW option. 

Opt. 3661 60 - CDMA option. 

Opt. 3661 + 72 - TV demodulation option. 

Opt. 3661 + 74 - Tracking generator option. 
Opt. 3661 + 78 - Channel Input setting option. 

ACCESSORIES (SOLD SEPARATELY) 

R16072 - Transit case. 

R16216A - Carrying case. 

R 16601 - Display hood. 

A02806 - Front cover. 

PROPAC14 BAH - Battery. 

DUAL2401 CHARGER - Charger. 

A09507 - 64 K byte SRAM memory card. 
A09508 - 256 K byte SRAM memory card. 
A09509 - 2 M byte SRAM memory card. 
A01434 - DC cable. 



Product(s) available through your local Tektronix 
Distributor listed in the back of this catalog. 

C€ 

ilDVANTEST 

Advantest's quality system complies with the 

DIN ISO 9002 standard and has been certified by TUV 

Product Service GMBH. 



184 SPECTRUM analyzers 



www.tektnmix.(oaVMeasiiicaMl/coaintcst/ 





Sp 

New 



ECTR 

R3132 



UM 

• New 



Analyzers 

3162 • New 3132N 




Features - Benefits 



Frequency Range - R3132: 9 kHz 
to 3 GHz; R3132N; 9 kHz to 
2.2 GHz; R3162: 9 kHz to 8 GHz 

Input Impedance 75 Q. model - 
R3132N 

High-speed GPIB, Effective for 
System Applications 

High Speed Measurement - 
20 Traces per Second 

6.5-inch TFT Color LCD 
Built-in Frequency Counter 
Floppy Disk for Data Saving 
Printer Port 
RS-232 Port 
VGA output 
20 dB Preamp 
QP Detector and EMC filters 



Applications 



Digital Radio Transmitter 
Characteristic Measurement 

Manufacturing Test 

EMC Testing (Precompliance) 

Education/Training 

Cable TV, EMC Measurements 

Digital Mobile Communications 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call; 
1-503-627-1916. 
inside the U.S. call: 
1-800-426-2200. 

C€ 

ilDVANTEST 

Advantesfs quality system 
complies with the 
DIN ISO 9002 standard and 
has been certified by TUV 
Product Service GMBH. 



OPTIONS 

► Narrow-band Resolution Bandwidth - 30 Hz, 
100 Hz, 200 Hz (EMI Bandwidth) and 300 Hz 

► High-stability Frequency Reference - Aging 
Rate 1 X 10~7year 

► High-speed Time Domain Sweep - 50 ps/10 div. 
(100 ns Resolution) 

► Tracking Generator - 100 kHz to 3 GHz 

The R3 132/3 162 series spectrum analyzers offer 
outstanding measurement capabilities and per- 
formance, at an affordable price. 

For various applications, such as Cable TV, 

EMC measurement and Digital Mobile. 
Communications, the R3132/3162 can be cus- 
tomized by selecting from available options. 

BASIC FUNaiONS 

Basic functions are reinforced so that the 
R3132/3162 can be used in various fields. For 
example, the internal automatic calibration 
function guarantees the total level accuracy of 



±1.5 dB; level correction factor can be stored in 
the internal memory, DDS is employed to 
improve frequency reading accuracy, and fre- 
quency span error is lowered to less than 1%. 

The R3 132/3 162 offer wider dynamic range and 
lower 2nd and 3rd order distortion by improving 
1 dB compression point. 

As a result of increasing the sweep repetition 
cycles by improving the synthesized local oscilla- 
tor, 20 traces/second (typ.) data rewriting becomes 
possible, enabling far more real-time waveform 
measurement. Also, the high speed GPIB increas- 
es the throughput of automatic measurement. 

FOR MANY APPLICATIONS 

For EMI precompliance measurement, 6 dB 
bandwidth filters (9 kHz, 120 kHz and 1 MHz) 
and a QP detector are equipped as standard. An 
optional 200 Hz narrow RBW filter can be added 
for EMC measurements. A high-speed time 
domain measurement function which is indis 



W¥iniv.tektroiiix.coiVMcasureiiieiiVcona^ 



SPECTRUM ANALYZERS 185 




Spectrum Analyzers 

NEW R3132 • NEW 3162 • NE W3132N 

pensable for mobile communications, is 
available as an option. 

By using the double-screen display 
function, you can specify the 
rising/falling edge of TDMA waveforms 
and display the magnified image. 

The R3132/3162 series spectrum ana- 
lyzer has AGP and OBW operation 
functions which are indispensible for 
evaluating the transmission characteris- 
tic of radio systems. 

With various other functions such as 
AUTO TUNE, 1 Hz resolution frequen- 
cy counter, dBc/Hz, %AM, and 
PASS/FAIL test by limit value, the 
R3132/3162 series can easily perform 
several types of measurements. 

Even for signals which are lower in 
amplitude than the average noise level, 
the preamplifier ensures level calibrat- 
ed, high-accuracy measurement. 

For measuring the attenuation charac- 
teristics of filters or the frequency char- 
acteristics of cables, etc., a built-in 
tracking generator is available as an 
option. Because the output level can be 
set in a wide range, it is possible to 
measure amplifier gain, frequency 
response, etc. 

EASY-OPERATION INTERFACE 

The high-resolution, 6.5-inch TFT color 
LCD provides easy-to-see display of 
data. A VGA output is provided for 
external display. 

Measured waveform data and setting 
condition can be saved in or recalled 
from the internal memory. Using the 
floppy disk drive which is equipped as 
standard, you can manage more meas- 
urement data. Text data or Bitmap data 
on floppy disk are also useful for mak- 
ing documents on a personal computer. 

As the hard-copy function is provided 
to ESC/P. ESC/P-R and PCL, measured 
data can be printed out on general- 
purpose printers. 

GPIB and RS232 are equipped as 
standard. 



186 SPECTRUM ANALYZERS 



Characteristics 



FREQUENCY 

Frequency Range - 9 kHz to 3 GHz (9 kHz to 
2.2 GHz for R3132N). 

Frequency Reading Accuracy (Start, Stop, 
Center Frequency, Marker Frequency) - 

± (Reading of frequency x Frequency reference 
accuracy + Span x 1% + Resolution bandwidth 
X 15% + 60 Hz). 

Counter - 

Resolution: 1 Hz to 1 kHz. 

Accuracy; ± (Marker frequency x Frequency 
reference accuracy + i LSD). 

Frequency Reference Accuracy - 
Stability: ±2 x lO'Vyear, ±1 x lO’Vyear (Opt.), 
±1 X 10-5 (Qo c to 50° C). 

Frequency Span - 

Range: 1 kHz to 3 GHz, 0 Hz. 

Accuracy: <±1%. 

Residual FM - <60 Hz p-p x 0.1 s. 

Signal Purity - 

<-105 dBc/Hz (20 kHz offset). 

<-100 dBc/Hz (10 kHz offset). 

Resolution Bandwidth (3 dB) - 

Range: 1 kHz to 3 MHz, 1-3-10 sequence, 30 Hz 

to 300 Hz (Opt.). 

6 dB bandwidth: 1 MHz, 120 kHz, 9 kHz, 

200 Hz (Opt). 

Video Bandwidth - 10 Hz to 3 MHz, 

1-3-10 sequence. 

AMPLITUDE RANGE 

Measuring Range - +30 dBm to the average 

of displayed noise level. 

Maximum Input Level - 
(Input ATT >5 dB) 

Preamplifier OFF: +30 dBm, ±50 VDC max. 
Preamplifier ON: +13 dBm, ±50 VDC max. 
Input ATT Range - 0 to 50 dB (5 dB step). 

DYNAMIC RANGE 
Average Noise Level - RBW 1 kHz, VBW 
10 Hz, input ATT 0 dB, for 1 MHz or more. 
Preamplifier OFF: -118 dBm + 2f (GHz) dB. 
Preamplifier ON: -132 dBm + 3f (GHz) dB. 

1 dB Gain Compression - At 10 MHz or 
more. 

Preamplifier OFF: >0 dBm (mixer input level). 
Preamplifier ON: >-30 dBm (RF input level). 



AMPLITUDE ACCURACY 

Frequency Response - After auto calibration. 

Preamplifier OFF: 

<±0.5 dB (100 kHz to 3 GHz, ATT=0 dB). 

<±1 dB (100 kHz to 2.7 GHz). 

<±2 dB (9 kHz to 3 GHz). 

Preamplifier ON: 

<±1 dB (100 kHz to 2.7 GHz). 

<±2 dB (9 kHz to 3 GHz). 

Calibration Signal Level Accuracy - 
-20 dBm ±0.3 dB. 

IF Gain Error - <±0.5 dB after auto calibration. 
Total Level Accuracy - ±1.5 dB (REF= -50 to 

0 dBm, ATT=10 dB, 2 dB/div, RBW=300 kHz, 
f >100 kHz, after auto calibration). 

SWEEP 

Sweep Time - 20 ms to 1000 s, 50 ps to 

1 s (Opt.). 

Accuracy - <±1%. 

Trigger Mode - FREE RUN, LINE, VIDEO, 

EXT, TV. 

Sweep Mode - REPEAT, SINGLE. 

I/O 

RF Input - 

Connector: N type female. 

Impedance: 50 Q (R3132) (nominal), 75 Q. 
(R3132N) (nominal). 

Probe Power - ±12 V, 4-pin connector. 

Calibration Output Signal - BNC female. 

30 MHz, -20 dBm. 

10 MHz Reference Input - BNC female, 50 
0 dBm to +16 dBm. 

External Trigger Input - BNC female. 

Sound Output (Demodulated Audio) - 

Small monophonic jack. 

GPIB Interface - IEEE-488 specification BUS 
connector. 

Serial Interface - D-sub 9-pin. 

Printer Interface - D-sub 25-pin, ESC/P, 
ESC/P-R, PCL. 

Video Out - VGA (15-pin, female). 

Floppy Disk - 3.5 inch, MS-DOS format. 

ENVIRONMENTAL 

Operating Temperature - 0 to +50° C. 

Humidity: RH 85% or less. 

Storage Temperature — 20 to +60° C, 

RH 85% or less. 

Power Supply - 100/200 VAC switchable. 

100 VAC: 100 to 120 VAC, 50 to 60 Hz. 

200 VAC: 200 to 240 VAC, 50 to 60 Hz. 
Dimensions - 424 (W) x 177 (H) x 300 (D) mm 
(without feet and connectors). 



www.tektronix.com/Measurement/commtest/ 





Spectrum Analyzers 

NEW R3132 • NEW 3162 • NEW 3132N 




m 



R3162 Specifications 

FREQUENCY 

Frequency Range - 9 kHz to 8 GHz. 
Frequency Range Band 



9 kHz to 3.4 GHz 


0 


3.2 GHz to 7.5 GHz 


1- 


6.5 GHz to 8 GHz 


1 + 



Frequency Reading Accuracy (Start, Stop, 
Center Frequency, Marker Frequency) - 

± (Reading of frequency x Frequency reference 
accuracy + Span x 1% + Resolution bandwidth 
X 15% + 60 Hz). 

Counter - 

Resolution: 1 Hz to 1 kHz. 

Accuracy: ± (Marker frequency x Frequency 
reference accuracy + 1 LSD). 

Frequency Reference Accuracy - 
Stability: ±2 x lO’Vyear, ±1 x lO'Vyear (Opt), 
±1 X 10-5(0“ C to 50° C). 

Frequency Span - 

Range: 1 kHz to 8 GHz, 0 Hz <±lo/o. 

Residual FM - <60 Hz p-p x 0.1 s. 

Signal Purity - 

<-105 dBc/Hz (20 kHz offset). 

<-100 dBc/Hz (10 kHz offset). 

Resolution Bandwidth (3 dB) - 

Range: 1 kHz to 3 MHz, 1-3-10 sequence, 30 Hz 

to 300 Hz (Opt). 

6 dB bandwidth: 1 MHz, 120 kHz, 9 kHz, 

200 Hz (Opt). 

Video Bandwidth - 10 Hz to 3 MHz, 

1-3-10 sequence. 

AMPLITUDE RANGE 

Measuring Range - +30 dBm to the average 

of displayed noise level. 

Maximum Input Level - (Input ATT > 5 dB). 
Preamplifier OFF: +30 dBm, 0 VDC max. 
Preamplifier ON: +13 dBm, 0 VDC max. 



Indication Range - 10 x 10 div. 

Log: 10, 5, 2, 1 dB/div. 

Linear: 10% of the reference level/div. 

Input ATT Range - 0 to 75 dB (5 dB step). 

DYNAMIC RANGE 

Average Noise Level - RBW 1 kHz, VBW 
10 Hz, input ATT 0 dB, for 1 MHz or more. 
Preamplifier OFF: 

Band 0:-118dBm + 2f (GHz) dB. 

Band 1-: -115 dBm. 

Band 1+: -115 dBm. 

Preamplifier ON: -132 dBm + 3f (GHz) dB (At 
1 MHz to 3.4 GHz). 

1 dB Gain Compression - 

At 10 MHz or more. 

Preamplifier OFF: >0 dBm (mixer input level). 
Preamplifier ON: >-30 dBm (RF Input level). 

AMPLITUDE ACCURACY 

Frequency Response - After auto calibration, 

after pre-selector peak adjustment. 

Preamplifier OFF: 

<±0.5 dB (100 kHz to 3 GHz, AH=0 dB). 

<±1 dB(100 kHz to 2.7 GHz). 

<±2 dB (9 kHz to 3.4 GHz). 

<±2 dB (3.2 GHz to 8 GHz). 

Preamplifier ON: 

<±1 dB (100 kHz to 2.7 GHz). 

<±2 dB (9 kHz to 3.4 GHz). 

Calibration Signal Level Accuracy - 
-20 dBm ± 0.3 dB. 

IF Gain Error - <±0.5 dB after auto calibration. 
Total Level Accuracy - ±1.5 dB (REF=-50 to 
0 dBm, AH=10 dB, 2 dB/div, RBW=300 kHz, 
f >100 kHz, after auto calibration). 



SWEEP 

Sweep Time - 20 ms to 1000 s, 50 ps to 
1 s (Opt.). 

Accuracy: <±1%. 

Trigger Mode - FREE RUN, LINE, VIDEO, 
EXT, TV. 

Sweep Mode - REPEAT, SINGLE. 

I/O 

RF Input - 

Connector: N type female. 

Impedance: 50 Q (nominal). 

Probe Power - ±12 V, 4-pin connector. 

Calibration Output Signal - 

BNC female, 50 W. 

30 MHz, -20 dBm. 

10 MHz Reference Input - 

BNC female, 50 W. 

0 dBm to +16 dBm. 

External Trigger Input - BNC female. 
Sound Output (Demodulated Audio) - 

Small monophonic jack. 

GPIB Interface - IEEE-488 specification BUS 
connector. 

Serial Interface - D-sub 9-pin. 

Printer Interface - D-sub 25-pin, ESC/P, 
ESC/P-R, PCL. 

Video Out - VGA (15-pin, female). 

Floppy Disk - 3.5 inch, MS-DOS format. 




ENVIRONMENTAL 
Operating Temperature - 

0 to +50“ C. 

Humidity: RH 85% or less. 

Power Supply - 100/200 VAC switchable. 
100 VAC: 100 to 120 VAC, 50 to 60 Hz. 

200 VAC: 200 to 240 VAC, 50 to 60 Hz. 
Safety - UL3111-1, CSAIOIO.I, IEC61010-1. 
Dimensions - 424 (W) x 177 (H) x 
300 (D)mm (without feet and connectors). 



Ordering Information 



For price information: Outside the IJ.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



R3132 

Spectrum Analyzer. 

R3162 

Spectrum Analyzer. 



OPTIONS: 

Opt. 20 - High-Stability frequency reference 
lxlOE-7/yr (aging rate). 

Opt. 27 - Narrow resolution bandwidths 30 Hz, 
100 Hz, 300 Hz and 200 Hz (EMI). 

Opt. 29 - Fast sweep speed 50 ps/10 div. (100 ns 
resolution). 

Opt. 74 - Tracking generator 100 kHz to 3 GHz. 



For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

CC 

ilDVANTEST 

Advantesrs quality system complies with the 

DIN ISO 9002 standard and has been certified by TUV 

Product Service GMBH, 



www.tektronix.com/Measurement/commtest/ 



SPECTRUM ANALYZERS 187 





Spectrum Analyzers 



U3641/N 




Features - Benefits 



Frequency Range: 9 kHz to 3 GHz 
Ultra-compact and Light Weight 
- 15 lbs. 

Three-way Power Supply - AC Line, 
External DC and Optional Battery 
Pack 

6 in. TFT Color LCD Display 
Synthesized Local Oscillator Yields 
High-stability Measurements 
Two PCMCIA Memory Card Slots 

Switchable Preamp for High- 
sensitivity Measurements 

Optional Internal Tracking 
Generator 

Built-in Adjacent Channel Power, 
Occupied Bandwidth and Channel 
Power Measurements 



Applications 



Digital Mobile Communications 
Field Measurements (TDMA or 
CDMA, PCS and Cellular) 

Spectrum Monitoring 

RF Component Testing with 
Internal Tracking Generator Option 

Fault Location in Antenna Feeds 
with BasePak Software 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 



Product(s) complies with 
IEEE Standard 488.2-1987. 

ilDVANTEST 

Advantest's quality ^stem 
complies with the 
DIN ISO 9002 standard and 
has been certified by TUV 
Product Service GMBH. 



U3641/U3641N Field Portable 
Spectrum Analyzers 

The U3641/N is a 3 GHz synthesized spectrum 
analyzer ideal for applications where portability 
is a must. With a base unit weight of 15 lbs. and 
the ability to run from AC, DC or optional bat- 
tery power sources, the U3641/N has been 
designed specifically to meet the needs of field 
installation and maintenance applications. The 
synthesized local oscillator allows high- 
precision and high-stability measurements. 
Furthermore, tlie unit features optional resolu- 
tion bandwidths down to 100 Hz. A fast zero 
span sweep speed of 50 ps allows characteriza- 
tion of TDMA signals, and its built-in measure- 
ment functions allow for easy verification of 
communication standard compliance. 

The U3041/N can be customized for a variety of 
applications by selecting from a wide range of 
available options. 



WIDE ARRAY OF ANALYSIS FUNCTIONS 

Along with functions such as a frequency count- 
er with a 1 Hz resolution and a 20 dB gain pre- 
amplifier, these analyzers come standard with 
measurement functions such as third order inter- 
modulation distortion, percent AM, occupied 
bandwidth and adjacent channel leakage power. 
GO-NO GO evaluations of the displayed wave- 
form can also be easily performed using the limit 
line and PASS/FAIL functions which allow 
upper and lower limits to be set on the screen. 

Using the user-define function, commonly 
used measurements can be easily assigned to 
function keys, allowing a user-created custom, 
easy-to-use menu. 

THE LIGHTEST FIELD ANALYZERS 
IN THEIR CLASS 

'Fhese analyzers are light and compact - 15 lbs. 
base unit, under 20 lbs. with battery. The easy- 
to-attach strap allows the analyzer to be carried 
on the shoulder for transport or during measure- 



108 SPECTRUM ANALYZERS 



www.lektronix.com/Measurement/commtest/ 





Spectrum Analyzers 

U364I/N 



ments. The rugged construction meets 
MIL-T-28800 and stands up to the harsh 
conditions of field use. 

CDMA MEASUREMENTS 

Addition of the CDMA Option 60 
enables easy one-button measurement 
of CDMA transmission characteristics 
including in-band spurious, occupied 
bandwidth, channel power and adja- 
cent channel power. Measurements 
are included for both base stations 
and mobile phones, at cellular and 
PCS frequencies. 

THREE POWER SOURCES 
TO CHOOSE FROM 

The U3641/U3641/N can operate not 
only on 100/200 V AC power, but also 
on +10 to +16 V DC or the optional 
battery pack. Choose the power 
source that matches your need for 
portable flexibility. 

LARGE COLOR TFT LCD DISPLAY 

The 6 in. color TFT LCD display 
enhances viewing of complex measure- 
ments. A built-in tilt mechanism allows 
adjusting the viewing angle ±15 degrees 
to improve visibility and efficiency. 

COMPUTER AND INTERFACE FRIENDLY 

These analyzers are well-suited for 
computer-based applications. Two 
PCMCIA memory card slots allow you 
to store and recall instrument settings 
and measurements. This data can also 
be transferred directly to a computer in 
CSV (comma separated variable) and 
BMP screen image formats. The memo- 
ry card slots incorporate a dust-proof 
shutter and an eject mechanism for reli- 
able operation even in difficult outdoor 
working conditions. 

RS-232C and GPIB ports are also stan- 
dard. This allows you to print hard- 
copies of spectrum information and to 
control the instruments from an external 
computer as well as send/retrieve data. 

Composite video out jacks are standard. 
The output of these spectrum analyzers 
can be easily projected for better view- 
ing in meetings or training sessions. 



www4ektronix.com/MeasoraneiiVconuDtesV 



Characteristics 



FREQUENCY RELATED 
Frequency Range - 

9 kHz to 3 GHz. 

Frequency Readout Accuracy - (Start, Stop, 
CF, Marker). 

±(marker frequency x frequency reference 
error + 5% x span + 15% x RBW + 10 Hz). 
Count Frequency Marker - 
Resolution; 1 Hz to 1 kHz. 

Count Accuracy: S/N ^5 dB, RBW >3 kHz, 

1 kHz < SPAN <200 MHz); ±(marker frequency 
X frequency reference accuracy + 1 LSD + 5 Hz). 
Frequency Reference Accuracy - 
±2 X lO'Vyear ±1 x lO'^ (at 0“ C to 50“ C). 
Frequency Span - 

Range; 1 kHz to 3.2 GHz, 0 Hz (Zero Span). 
Accuracy: U3641/N: <±5% (SPAN). 

Frequency Stability - 

Residual FM: <60 Hz p-p/100 ms (ZERO span). 

Frequency Drift: <150 H^min (SPAN <10 kHz). 

Noise Sidebands - 

20 kHz Offset: <-105 dBc. 

10 kHz Offset: <-100 dBc. 

Resolution Bandwidth (3 dB) - 
Range: 1 kHz to 3 MHz, 1-3 sequence. 

U3641, Opt. for 100, 300 Hz. 

Selectivity; 

<15:1 (60 dB to 3 dB, RBW 1 kHz to 3 MHz), 
(conforming to CISPR standard). 

Video Bandwidth - 10 Hz to 3 MHz (1-3 step). 

AMPLITUDE RELATED 
Amplitude Range - 

U3641: 

+20 dBm to displayed Average Noise Level. 
U3641N: 

+130 dBpV to displayed Average Noise Level. 
Maximum Input Level 
(±50 V DC maximum) - 

Preamplifier OFF (Input Atten >10 dB): 
U3641:+27 dBm. 

U3641N:+134 dBpV. 

Preamplifier ON (input atten >10 dB): 
U3641:+13 dBm. 

U3641N;+120 dBpV. 

Display Range - 

Log; 10 X 10 div, 10, 5, 2, 1 dB/div. 

Linear: 10% of reference level/div, RBW >3 kHz. 



Reference Level Range (U 3641 /N) - 

Preamplifier OFF (Input Atten 0 dB to 50 dB); 
Log: U3641, -64 dBm to +40 dBm; 

U3641N, +46 dBpV to +150 dBpV. 

Linear: U3641, +141.1 pV to +22.36 V; 

U3641N, +198.4 pV to 31.44 V. 

Preamplifier ON (Input Atten 0 dB to 10 dB); 
Log: U3641, -89 dBm to -25 dBm (0.1 dB 
step); U3641N, +21 dBpV to +85 dBpV. 

Linear: U3641, +7.934 pV to +12.57 mV; 
U3641N, +11.16 pV to 17.68 mV. 

Input Attenuator Range - 

0 to 50 dB (10 dB step). 

SWEEP RELATED 
Sweep Time - 

50 ps to 1000 s and manual sweep. 

Accuracy - <± 5 %. 

Trigger Mode - 

Free Run, Single, Video, Ext, TV. 

DEMODULATION 
Spectrum Demodulation - 

Modulation Type: 

AM and FM (FM at RBW > 3 kHz). 

Audio Output: Speaker and phone jack with 
volume control. 

DYNAMIC RANGE 

Displayed Average Noise Level (RBW 

1 kHz, VBW 10 Hz) - 

Preamplifier OFF: 

U3641:-117 dBm + 2.7 f (GHz) dB. 

U3641/N: -8 dBpV + 2.7 f (GHz) dB. 
Preamplifier ON: 

U3641 : -135 dBm + 4.3 f (GHz) dB. 

U3641/N: -26 dBpV + 4.3 f (GHz) dB. 

Cain Compression (I dB) - 
Preamplifier OFF (mixer input level, 
f >10 MHz); 

U3641:>-10dBm. 

U3641/N: >+100 dBpV. 

Preamplifier ON (RF input level, f >10 MHz): 
U3641 (AH = 0): >-40 dBm. 

U3641/N: >+70 dBpV. 

Spurious Response 

(Input Atten 0 dB,f >10 MHz) - 

Preamplifier OFF: 

Second Harmonic Distortion; 

U3641 : <-70 dB (-30 dBm input). 

U3641/N; <-70 dB (+78 dBpV input). 

Third Order Intermodulation Distortion: 

U3641 : <-70 dB (-30 dBm input). 

U3641/N; <-70 dB (+78 dBpV input). 

Residual Responses 

(Input Atten 0 dB, f >10 MHz) - 

Preamplifier OFF: 

U3641 : <-100 dBm, 50 L2. 

U3641/N; <+10 dBpV, 75 Q. 

Preamplifier ON: 

U3641:<-105 dBm, 50 Q. 

U3641/N: <+5 dBpV, 75 Q. 

SPECTRUM ANALYZERS 189 





Spectrum Analyzers 

U3641/N 



AMPLITUDE ACCURACY 
Frequency Response (Input Atten 10 dB, 
20* C to 30* C, referenced to 30 MHz, 
after calibration) - 

Preamplifier OFF; 

U3641; <±1 dB (100 kHz to 2.7 GHz); 

<2 dB (9 kHz to 3.0 GHz). 

U3641/N: <±1 dB (100 kHz to 2.7 GHz). 
Preamplifier ON: 

U4342: <±1 dB (100 kHz to 2.7 GHz). 

U3641 : <+2 dB (9 kHz to 3.0 GHz). 

U3641/N; <±1 dB (100 kHz to 2.2 GHz). 

Calibration Signal Accuracy - 

U364r.-20 dBm ±0.3 dB. 

U3641/N; +90.5 dBpV ±0.3 dB. 

IF CAIN UNCERTAINTY 
(after automatic calibration) - 

^0.5 dB. 

Scale Fidelity (after automatic 
calibration) - 

Log; <±1.5 dB/90 dB; <±1 dB/10 dB; 

<±0.2 dB/1 dB. 

Linear: <±5% of reference level, RBW 3 kHz. 

Input Attenuator Switching Accuracy 
(10 dB reference, 20 dB to 50 dB setting) - 

U3641; 

100 kHz to 2.7 GHz: <±1.0 dB. 

9 kHz to 3.0 GHz: <±1.5 dB. 

U3641/N; 

100 kHz to 2.2 GHz; <±1.0 dB. 

Resolution Bandwidth Switching 
Uncertainty (after automatic calibration) - 

< ± 1.0 dB at RBW 3 MHz. 

INPUTS AND OUTPUTS 
RF Input - 

Connector; N-type jack. 

Impedance; 

U3641 50 Q (nominal). 

U3641/N 75 Q (nominal). 

VSWR: 

Preamplifier OFF: 

100 kHz to 2 GHz: <1.5:1. 

9 kHz to 3.0 GHz (2.2 GHz 
U3641/N): <2:1. 

Preamplifier ON: 

10 MHz to 3.0 GHz (2.2 GHz U3641/N): <2.5:1. 
10 MHz to 2.0 GHz (U4941/N); <2:1. 

10 MHz Reference Input - 

Connector: BNC jack, rear panel. 

U3641/N: 

Impedance: 50 £2 (nominal). 

Input Range: 0 dBm to +16 dBm. 

Video Output - 
Connector; BNC jack, rear panel. 

Impedance: 75 Q (nominal), AC coupled. 
Amplitude; Approx. 1 V p-p, 75 Q (composite 
video signal). 



External Trigger Input - 

Connector: BNC jack, rear panel. 

Impedance 10 k£2 (nominal), DC coupled. 
Trigger level; TTL level. 

Cate Input - 

Impedance; 10 k£2 (nominal). 

Sweep step; During TTL low level. 

Sweep continue: During TTL high level. 

Phone Output - 

Connector: Subminiature monophonic jack, 
front panel. 

GPIB Interface - 
Connector: IEEE-488 bus. 

Plotter: HP-GL commands (682-XA). 

Printer; PCL commands. 

RS-232 - 

Connector: D-SUB 9-Pin, rear panel. 

Memory Card - Two memory card slots, 
JEIDA-Ver.4.1, PCMCIA Rel. 2.0, Type 1. 

HIGH STABILITY REFERENCE SOURCE 
(OPT. 20 ONLY, U3641/N) 

Frequency - 10 MHz. 

Frequency Accuracy - 

±2 X 10‘®/day. 

±1 X 10‘Vyear. 

PHS-ID DEMODULATOR FUNCTION 
(OPT. 70 ONLY, U3641) 

Opt. 20 and Opt. 70 cannot be installed simul- 
taneously. 

Signal Reception - 

Radio access format - TDMA-TDD. 

Modulation format: pi/4 DQPSK. 

Transmission speed; 384 Kbits/s. 

Signal channel: Logic control channel code 
configuration conforms to RCR STD-28. 

Levei Measurement Range - 
Reception performance: 

Preamplifier OFF (Input Atten = 10 dB): 

52 dBpVto 107dBpV. 

Preamplifier ON (Input Atten = 0 dB): 
16dBpVto67dBpV. 

Sweep Trigger Modes: Free Run, Video, ID. 
Measurement Functions - 
ID List displays; Cl, CS-ID, PS-ID, level, time. 
ID-MKR: Display of specified signal ID. 

Period measurement; Measurement of 
specified CS-ID. 

Burst Error Rate - The number of error 
slots/The measured (Set) number. 

Levei Measurement Operations - 
Center value processing. 

Average value processing. 

Max/min. value processing. 



TV DEMODULATION FUNCTION 
(OPT. 72 ONLY) U3641/N 
TV Demodulation - 

Demodulation type: NTSC, PAL, SECAM. 

TV standard: M, B/G, D/K/K', I, L/L'. 

Output; Video, sound. 

TV image Demodulation Output - 
Connector: BNC jack, rear panel. 

Impedance; 75 Q (nominal), DC coupled. 
Amplitude: Approx. 1 Vp.p, 75 £2. 

TV Sound Demoduiation Output - 
Connector: Pin jack, rear panel. 

Impedance: 1 k£2 (nominal), AC coupled. 

TV Image Signal Input - 
Connector: BNC jack, rear panel. 

Impedance: 75 £2 (nominal), AC coupled. 
Input Level: About 1 Vp.p. 

TV Sound Signal Input - 
Connector: Pin jack, rear panel. 

Impedance: 1 k£2 (nominal), AC coupled. 

TRACKING GENERATOR FUNCTION 

Opt. for U3641/N. 

Frequency Range - 100 kHz to 2.2 GHz. 
Output Level Range - 

0 dBm to -31 dBm, 1 dB steps. 

N Version: 105 dBpV to 74 dBpV, 1 dB steps. 

Output Level Accuracy - 

at 30 MHz, -10 dBm; <0.5 dB. 

N Version; at 30 MHz, 95 dBpV; <0.5 dB. 

Output Level Flatness - 

(at -10 dBm, 30 MHz reference): 

100 kHz to 1 GHz; <±0.7 dB. 

100 kHz to 2.2 GHz: <±1.5 dB. 

N Version (at 95 dBpV, 30 MHz reference): 
100 kHz to 1 GHz: <±0.7 dB. 

100 kHz to 2.2 GHz; <±1.5 dB. 

Output Level Switching Accuracy - 
(at -10 dBm reference): 

100 kHz to 1 GHz: <±1.0 dB. 

100 kHz to 2.2 GHz: <±2.0 dB. 

N Version (at 95 dBpV reference): 

100 kHz to 1 GHz: <±1.0 dB. 

100 kHz to 2.2 GHz: <±2.0 dB. 

Output Spurious - 
Harmonic: <-20 dBc. 

Non-harmonic: <-30 dBc. 

Tracking Generator Leakage - 
<-95 dBm. 

N Version; <-16 dBpV. 

Tracking Generator Output - 

Connector: N-type jack. 

Impedance: 

50 £2 (nominal). 

N Version: 75 £2 (nominal). 

VSWR: 

(<-10 dBm output); <1.5. 

N Version (<-10 dBpV output): <2.0. 



190 SPECTRUM ANALYZERS 



www.tektronix.com/Measurement/comnitest/ 



Spectrum Analyzers 

U3641/N 



CHANNEL INPUT SETTING (OPT. 78 
ONLY, U364I/N) 

(Opt. 78 is included in Opt. 72.) 

Channel Setting - Channel setting for VHF, 
UHF, CATV, BS and CS. Two user tables are 
available and 99 channels can be registered for 
each table. 

ENVIRONMENTAL 
Temperature - 

Operating: 0° C to 50° C. 

Nonoperating: -20° C to +60° C. 

Humidity - 85% or less. 



POWER REQUIREMENTS 
External DC Input - 

Connector: XLR 4-Pin. 

Voltage range: +10 V to +16 V. 

Power consumption: 60 W maximum. 

AC Input - 

Line voltage: 100 VAC and 200 VAC, 
auto switching. 

Voltage range: 

100 V operation: 90 V to 120 V. 

220 V operation: 220 V to 240 V. 

Line frequency: 50 Hz/60 Hz. 

Power consumption: 100 VA maximum. 



Physical characteristics 



Dimensions (without feet or connectors) 




mm 


in. 


Height 


148 


5.75 


Width 


291 


11.375 


Depth 


330 


13.25 


Weight (without options, accessories, carrying 


belt batteries) 








hf 


lbs. 


U3641/N 


6.9 


15.2 



Ordering Information 



For price information: Outside the II.S. contact 

U3641 

Portable Spectrum Analyzer, 50 Q. Input. 

U3641N 

Portable Spectrum Analyzer, 75 Q. Input. 

Includes: Power Cable (A01402), N-to-BNC Adapter 
(U3641 -JUG-201A/U), NC-to-BNC Adapter 
(U3641N - BA-A165), N-C15 Adapter 
(U3641N - (NCP-NFJK), AC-DC Adapter (A08364), 
Carrying Strap, Operation Manual, SRAM card. 

OPTIONS 

Opt. 15 - Program controller. 

Opt. 20 - High-stability reference (cannot be 
installed with Opt. 70). 

Opt. 26 - Narrow RBW filters (300/100 Hz). 

Opt. 60 (U3641 only) - CDMA measurement 
IS-95/J-STD-008 TX measurement for U3641 only. 
Opt. 70 (U3641 only) - PHS demodulation (cannot 
be installed with Opt. 20 or Opt. 72). 

Opt. 72 - TV demodulation (cannot be installed 
with Opt. 70, includes Opt. 78). 

Opt. 74 - Tracking generator. 

Opt. 78 - Channel input setting (included 
with Opt. 72). 



your local Tektronix representative, inside the U.S. 

MEASUREMENT SERVICE OPTIONS 
U3641/N 

Opt. C3 - Three years of calibration services. 

Opt. D3 - Test data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover 
three years. 

RECOMMENDED ACCESSORIES 

Battery - Order 146-0111-00 (requires charger). 

Battery Charger - Order 119-4901-00. 

External DC Power Cable - Order A01434. 
Memory Card, 64K - Order A09507. 

Soft Carrying Case - Order R16216. 

Transit Case - Order R16072. 

Front Panel Cover - Order A02806. 

Carrying Handle - Order A08184. 

Display Hood - Order R 16601. 



the price list in the back of this catalog. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 




Product(s) complies with IEEE Standard 488.2-1987. 

ilDVANTEST 

Advantesfs quality system complies with the 

DIN ISO 9002 standard and has been certified by TUV 

Product Sen/ice GMBH. 



see 



www.tektronix.com/Mea$ureiiieiit/comintest/ 



SPECTRUM ANALYZERS 



191 




Spectrum Analyzer 

New R3131 




0 



3 



Features - Benefits 



Built-in High Accuracy OBW, ACP, 
and Power Measurement Functions 
Which Can Be Applied to Digital 
Radio Measurement 
Improved Ease of Use Through 
Auto TUNE Function 
Total Level Accuracy Guaranteed by 
Auto CAL Function 
Standard Interfaces: GPIB, RS232, 
Centronics, and FD Drive 
Large Character Display Allows 
Results to Be Seen 
EMC Measurement Functions 
Improved System Operation Speed 
Operation Key Arrangement for 
Ease of Use 

Compact and Light Weight (12 kg) 
with a Space-saving Design 

Optional Tracking Generator for 
Scalar Transmission Measurements 



Applications 



Digital Radio Transmitter 
Characteristics Measurement 

EMC Diagnostic Testing 
Education/Training 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 

C€ 

ilDVANTEST 

Advantest's quality ^stem 
complies with the 
DIN ISO 9002 standard and 
has been certified by TUV 
Product Service GMBH. 



An Affordable Personal Spectrum 
Analyzer with Performance to 
Match Many Applications 

The R3131 is an easy-to-use personal spectrum 
analyzer which combines high accuracy neces- 
sary for digital radio measurement with excellent 
operability and usability. The R3131 can be used 
in diverse fields, for a multitude of applications. 



Lots of Standard Features 

The R3131 includes a number of standard fea- 
tures that normally are available only as 
options. These include an IEEE 488 interface, 
RS-232 interface and parallel printer 
(Centronics) port. A 3.5 inch floppy disk is also 
provided at no extra charge, as is an EMC 
Measurement function. 

Measurement parameters and results can be 
recorded on a 3.5 inch floppy disk. Because the 
bitmap and text formats are compatible, the 
recorded data can easily be transferred to a PC. 



192 SPECTRUM ANALYZERS 



www.tektroiUx.co«/ll(leasure««iVc^ 




Spectrum Analyzer 

NEW R3131 



Independent Operation Keys 
Improve Operability 

AUTO TUNE 

Searches for the signal with the maxi- 
mum level within the 3 GHz band and 
sets the center frequency automatically. 

COUNTER 

Performs frequency measurement with 
the built-in frequency counter simply 
by moving the marker to the signal. 

POWER MEASURE 

The R3131 can measure the power with- 
in the specified band of frequency dif- 
fuse signals and the total power of multi- 
carrier signals. It can also be used to 
measure the occupied fi'equency band- 
width (OBW) and adjacent channel leak- 
age power (AGP) which are essential to 
transmission characteristics testing for 
radio equipment. 

CHANNEL POWER 

The R3131 allows you to measure the 
total power within the window and dis- 
play it as the channel power. 

TOTAL POWER 

Obtains the total power from the spec- 
trum displayed on the screen. This 
function is useful for total power meas- 
urement of multi-carrier signals. 

GATED SWEEP 

The R3131 allows spectrum analysis of 
the burst signal by supplying a trigger 
signal synchronizing with the burst 
transmission. 

SAVE/RECALL 

The R3131 allows you to store and recall 
measured waveform data and measiue- 
ment conditions. The R3131 unit offers 
up to 10 dedicated files for storage. 




PASS/FAIL 

Sets the limited judgment value for the 
level axis using a window. If the mark- 
er falls within the window, the PASS 
judgment results; otherwise, the FAIL 
judgment results. 

EMC 

This function measures electromagnetic 
interference generated by various elec- 
tronic equipment. This function incor- 
porates the 9 kHz and 120 kHz RBW 
and QP detector conforming to the 
CISPR Pub.16-1 standard. In addition, 
using the AM/FM demodulation signal 
fed from the PHONE jack on the rear 
panel, you can identify broadcasting 
radio waves which act as external noise. 



Characteristics 



FREQUENCY 

Range: 9 kHz to 3 GHz. 

Marker counter resolution: 1 Hz to 1 kHz. 
Frequency span: zero, 50 kHz to 3 GHz. 
Frequency stability Residual 
FM: < 100 HZp.p/100 ms (zero span). 
Sideband noise: <100 dBc/Hz (20 kHz offset). 
Resolution 3 dB bandwidth: 1 kHz to 1 MHz, 
1-3 step. 



AMPLITUDE 

Maximum input level: +20 dBm, 50 VDC. 

Display range - 

LOG: 10 dB/div 8 div, 1,2,5 dB/div, 10 div. 

Reference level range - 

LOG: -64 dBm to + 40 dBm, 1 dB steps. 

SWEEP 

Sweep time: 50 ms to 500 s. 

DISPLAYED NOISE LEVEL 

Average noise level: -113 dBm +2 f (GHz) dB 
(at RBW 1 kHz, VBW 10 Hz, INPUT ATT 0 dB, 
frequency >1 MHz). 

Residual response: < -100 dBm. 

(Frequency > 1 MHz, INPUT ATT = 0 dB, input 
50 n terminated). 

AMPLITUDE ACCURACY 

Frequency response: <±0.5 dB (100 kHz to 
3GHz,An=10dB). 

<±1 dB (100 kHz to 2 GHz). 

< ±2 dB (9 kHz to 3 GHz). 

(after calibration at 30 MHz reference). 

GENERAL SPECIFICATIONS 
Operating Conditions - 0° C to +50® C, 85% 
RH max. (without condensation). 

Storage Conditions - -20® C to + 60® C. 
Power Supply - 100/200 VAC, auto switching. 
100 VAC; 100 V to 120 V, 50 Hz^0 Hz. 

220 VAC; 220 V to 240 V, 50 Hz/60 Hz. 

Power Consumption - 
200 VA max. (100 VAC). 

Safety - UL3111-1, CSAIOIO.I, EN61010-1, 
IEC61010-1. 

PHYSICAL CHARAaERISTICS 



Dimensions 


mm 


Height 


177 


Width 


424 


Depth 


300 


Weight 


ks 


R3131 


12 



Windows is a trademark of Microsoft 
Corporation. 



Ordering Information 



see the price list in the back of this catalog. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916. inside the U.S. call: 1-800-426-2200. 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. 

R3131 OPTIONS 

Spectrum Analyzer. Opt. 74 - Tracking Generator. 



cc 

2IDVANTEST 

Advantesfs quality system complies with the 

DIN ISO 9002 standard and has been certified by TUV 

Product Service GMBH. 



www.tektronix.com/Measuremeflt/commtest/ 



SPECTRUM ANALYZERS 193 







Spectrum Analyzers 

2712 • 2711 




Features - Benefits 



2712 

High Value, Low Cost 
5 X 10"^ Frequency Accuracy 

Sensitivity to -139 dBm 

(-92 dBmV) with Built-in Preamp 

Internal Frequency Counter 

4 Trace Digital Plus True 
Analog Display 

124 K of RAM 



Applications 



Broadcast Transmitter Performance 

Communications System 
Operations 

EMC Prequalification Testing 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 

C€ 

jgisomi 

Tektronix measurement 
products are manufactured in 
ISO registered facilities. 




Product(s) complies with IEEE 
Standard 488.1-1987, 
and with Tektronix Standard 
Codes and Formats. 



Easy to Use 

Dedicated Numeric Keypad Plus 
Logically Grouped Menu Keys 

Powerful Built-in Measurement 
Routines 

EMC Measurements with Optional 
Quasi-peak Detector 

Swept Measurements to 1 .8 GHz 
with Optional Internal or External 
Tracking Generator 

2711 

Economical, Can Be Configured to 
Meet Most Budgets 

High Portability 

Internal or External Tracking 
Generator Option 

Internal Frequency Counter (Opt. 02) 
GPIB or RS-232 Interface Option 

Excellent Frequency Accuracy and 
Sensitivity 



2712 Spectrum Analyzer 

The Tektronix 2712 Spectrum Analyzer provides 
excellent RF performance, a built-in frequency 
counter, full programmability, digital and true 
analog displays, high portability, enough non- 
volatile memory for 108 saved displays and 
much more. 



A straightforward human interface, with conve- 
niently grouped, dedicated front-panel keys and 
simple, menu-driven functions makes the 2712 
easy to learn and use. You can set frequency, 
span and reference level directly from the front 
panel. A real-time clock provides an on-screen 
date and time display, plus date/time stamp 
capability for waveform printouts. 



194 SPECTRUM ANALYZERS 



vmw.tektronix.com/Measurement/commtest/ 






Spectrum Analyzers 

2712*2711 



Frequency-corrected tuning and phase- 
lock stabilization enhance the ability to 
resolve close-in signals and reliably 
demodulate narrowband signals. 
Sensitivity up to -127 dBm (-80 dBmV) 
at 300 Hz resolution bandwidth (RBW) 
lets you see weak signals. The built-in 
preamp can improve sensitivity another 
12 dB, up to -139 dBm (-92 dBmV). Up 
to 80 dB on-screen dynamic range 
ensures visibility of weak signals in the 
presence of strong ones. 

A 300 Hz RBW filter with a shape factor 
<7:1 means you’ll see many close-in 
sidebands and spurious or unexpected 
signals you might otherwise miss. At 
the other end of the spectrum the 
5 MHz RBW filter is useful when 
demodulating wideband signals such as 
actively modulated video carriers. 

The built-in signal counter, with 
0.5 ppm ±10 Hz accuracy, offers added 
power for rapidly identifying signals. 
The capability to choose between digi- 
tal and true analog displays lets you 
examine signals for characteristics that 
are not visible on digital-only displays. 

Sweep speeds of 1 psec/div, TV Line 
and TV Field triggering, an internal 
audio amplifier and AM/FM detectors 
and the optional Video Monitor Mode 
all make video communications meas- 
urements easier. 

Bandwidth, Carrier-to-Noise, Noise 
Power, Signal Search and FM Deviation 
modes provide additional measurement 
power and convenience. Occupied 
Bandwidth Mode, with percent settable 
from 1 to 99%, aids in broadcast and 
radio measurements. 

The optional internal or external track- 
ing generator provides high dynamic 
range swept measurements to 1.8 GHz. 

EMC MEASUREMENT 

To help simplify your EMC measure- 
ments, the 2712 offers an optional 
quasi-peak detector, EMI resolution 
bandwidth filters and fully corrected 
E-field intensity measurements to 
assist in pre-certification and trou- 
bleshooting. EMC ancillary devices 
are available to provide a complete 
measurement solution. 




2711 

2711 Spectrum Analyzer 

The 2711 offers a wide range of features 
at an extremely affordable price. This 
value leader is well-suited for checking 
broadcast transmitter performance and 
communications system operations, 
looking for unwanted RF emissions, 
testing two-way communications equip- 
ment, maintaining industrial security 
and teaching frequency domain con- 
cepts in the classroom, plus a wide 
variety of other applications. 

The standard 2711 shares many of 
2712’s valuable features, such as com- 
pact size and light weight (9.5 kg, about 
21 lbs.). Both instruments can also be 
quickly converted to rack operation 
with optional rackmount adapters. 

SELECTION GUIDE 



Frequency accuracy is 1 x 10"^ and sen- 
sitivity is up to -117 dBm (-70 dBmV) 
at 3 kHz RBW. The built-in preamp can 
add another 12 dB, up to -129 dBm 
(-82 dBmV). Up to 80 dB on-screen 
dynamic range helps see weak signals, 
even when strong ones are present. 

True analog display capability, along 
with fast sweep speeds and TV Line 
and TV Field triggering provide con- 
venient demodulation of video carriers 
for making depth-of-modulation checks 
or looking at special baseband 
data, VITS and many other signals. 

An internal audio amplifier and 
AM/FM detectors let you hear demodu- 
lated signals, using either the built-in 
speaker or headphone jack, for fast sig- 
nal identification and trouble-shooting 
in communications applications. 

With the Video Monitor (Opt. 10) 
installed, you can view broadcast (AM) 
TV signals or down-converted satellite 
(FM) signals. 

The 2711 can also be used with a set of 
near-field probes as a handy EMC diag- 
nostic tool. 



GipabilitY 


2712 


2711 


Frequency Range 


9 kHz to 1.8 GHz 


9 kHz to 1.8 GHz 


±0.5 ppm Freq. Accuracy 


Std. 


NA 


Signal Counter 


Std. 


Opt 02 


GPIB Interface 


Std. 


Opt 03 


Internal Tracking Gen. 


Opt 04 


Opt 04 


External Tracking Gen. 


Opt 05 


Opt 05 


RS-232C Interface 
(replaces GPIB) 
(no charge) 

(no charge) 


Opt. 08 
Opt. 08 




Video Monitor Mode 


Opt 10 


Opt 10 


EMC Pre-certification 


12 


NA 


Measurements 


TV Sideband 


. opt 15 


Opt 15 


Adapter Interface 


Nonvolatile Memory 


124 K 


28 K (124 K with Opt 03 or 08) 


High Portability 


Yes 


Yes 


Both Digital and True Analog Displays 


Yes 


Yes 


Dedicated Numeric Keypad 


Yes 


Yes 


Real-time Clock 


Std. 


With Opt 03 or 08 



www.tektronix.com/Measurement/commtest/ 



SPECTRUM ANALYZERS 195 




Spectrum Analyzers 

2712 >2711 



Characteristics 



The following characteristics apply to both the 
2712 and 2711 after a 15-minute warm-up peri- 
od, unless otherwise noted. 

FREQUENCY RELATED 
Frequency Range - 9 kHz to 1800 MHz. 
Center Frequency Accuracy - 
2712: 5x10-7 of CF ±700 Hz. 

2711: 1x10-5 of CF ±5 kHz. 

Frequency Counter Accuracy (Std. 2712, 
Opt. 02 2711) - 

2712: 5x10-7 of CF ±10 Hz, ±1 LSB. 

2711: lxlO-5 ofCF±10Hz,±l LSB. 

2711: <2 kHz p-p/20 msec. 

Resolution Bandwidth (-6 dB) - 

2712: 5 MHz, 300 kHz, 30 kHz, 3 kHz, 300 Hz. 

2711: 5 MHz, 300 kHz, 30 kHz, 3 kHz. 

2712 with Opt. 14: Add 1 MHz, 100 kHz, 10 kHz, 
and 1 kHz. 

2712 with Opt. 12: add 1 MHz, 120 kHz, 9 kHz, 

1 kHz - 200 Hz replaces 300 Hz filter. 
Resolution Bandwidth Shape Factor 
(60 dB/6 dB) - ^:1 for RBW <1 MHz. 

Noise Sidebands - :^0 dBc at 30 x RBW. 

Video Filter - 

Approx. 1/100 (Auto) of RBW. 

Manual Selection: 3 Hz to 300 kHz in 
1-3 sequence. 

Freq. Span/Div. Range - 
2712: 180 MHz to 1 kHz. 

2711 : 180 MHz to 10 kHz selected in 1-2-5 
sequence or within two significant digits via 
menu. 

Span Accuracy - ±3% over the center eight 
divisions. 

AMPLITUDE RELATED 
Flatness - ±1.5 dB measured with 10 dB inter- 
nal RF attenuation (preamp off). 

Vertical Display Modes - 10, 5, 1 dB/div, 
Linear. 

Measurement Range - 

2712: -139 (preamp on) to +20 dBm (-92 to 
+67 dBmV). 

2711: -129 (preamp on) to +20 dBm (-82 to 
+67 dBmV). 

Display Dynamic Range - 80 dB max (limit- 
ed to 40 dB in optional 2712 Quasi-peak 
Detector mode). 

RF Attenuation Range - 0 to 50 dB, 2 dB 

steps. 

Sensitivity - 

2712: -127 dBm (-80 dBmV) at 300 Hz 
RBW, -139 dBm (-92 dBm\0 at 300 Hz RBW 
with preamp on (to 600 MHz). 

271 1 : -1 17 dBm (-70 dBmV) at 3 kHz 
RBW, -129 dBm (-82 dBmV) at 3 kHz RBW 



with preamp on (to 600 MHz). 

SPURIOUS RESPONSE (PREAMP OFF) 
Residual Spurious Response - <-100 dBm 
referenced to input of 1st mixer. 

3rd Order IM Distortion - <-70 dBc, from 
any two on-screen signals within any frequen- 
cy span measured with 1st mixer input level of 
<-30 dBm (+17 dBmV). 

2nd Harmonic Distortion - <-66 dBc meas- 
ured with 1st mixer input level of <-40 dBm 
(+7 dBmV). 

INPUT RELATED 

LO Emission - <-70 dBm with 0 dB RF 
attenuation. 

RF Input - Type N connector, 50 Q. 

VSWR with 10 dB or More RF 
Attenuation - 1.5:1 max. 

Maximum Safe Input - +20 dBm 

(+67 dBmV) (0.1 W) continuous peak with 0 dB 
RF attenuation; 100 V DC (initially applied with 
full attenuation). 

1 dB Compression Point - >-15 dBm 
(+32 dBm\0 with 0 dB RF attenuation. 

SWEEP RELATED 

Sweep Times - 1 psec to 2 sec/div in 1-2-5 
seq. (7-decade range); AUTO SWEEP mode; 
MANUAL SWEEP select. 

Trigger - Free run, internal, external, line, 

TV field, TV line, single sweep, manual scan. 

INPUT/OUTPUT CHARAaERISTICS 
External Trigger*’ - 

BNC connector, 10 kO. Impedance, DC coupled 
0.1 ps min. pulse width. 35 V max. 

External Video Input*’ - 
DC coupled. 0-50 kHz, 0-1.4 V (175 mV/dlv 
typical) signal input for vertical deflection of 
CRT beam. 

ENVIRONMENTAL SPECIFICATIONS 
Temperature - 

Operating: 0° to 50° C (MIL-T-28800D). 
Nonoperating: -55° to +75° C. 
Electromagnetic Compatibility - 
EC92 EMC Directive 89/336/EEC: 

Emissions: EN50081-I. 

Radiated Emissions, 30 MHz to 1 GHz, 

EN55022 Class B (CISPR 22 B). 

Conducted Emissions, 150 kHz to 30 MHz, 
EN55022 Class B (CISPR 22 B). 

Vibration - Meets MIL-T-28800E, Paragraph 
4.5.5.3.1 (modified). 

GENERAL CHARACTERISTICS 
Power Requirements - 105 W max. (1.4 A) 
at 115 V, 60 Hz. Operates 48 Hz to 440 Hz, 90 
to 132 V AC, or 48 Hz to 63 Hz to 250 V AC. 
Battery power (Opt. 07) available. 



Physical 

Dimensions 


Characteristics 

mm in. 


Height 


137*’ 


5.4*' 


Width 


361*’ 


14.2*> 


Depth 


445*1 


17.5*« 


Weight kg lb$. 



Net 9.;^ 

With feet, handle and front panel cover. 
Nominal for basic configuration. 

OTHER CAPABILITIES 
Markers - Single marker/delta marker; next 
right, next left peaks; next lower, next higher 
peaks: (highest) peak find; marker to center 
frequency and reference level. 

Nonvolatile Memory - 
Lithium battery backup. 

2712: 124 KB available; up to 108 displays saved; 
36 front-panel setups, large user-definable key 
routines and antenna tables (exact number and 
size depends on NV RAM utilization). 

2711: 28 KB available; up to 18*^ displays 
saved and 9*^ front-panel setups, user-defin- 
able key routines and antenna tables. 

Digital Storage Display - Selectable acquisi- 
tion modes of positive peak only, positive/neg- 
ative peak. SAVE A, B, C and active D trace; up 
to four traces on screen; MAX HOLD A, B; MIN 
HOLD A, B, C; B, C MINUS A; WATERFALL dis- 
play mode; digital storage off provides analog 
sweep. 

Ensemble Averaging - Provides weighted 
continuous or discrete averaging of display 
resulting In reduction of random noise. 
Internal Preamp - Preamp can be switched 
in/out of circuit (flatness degrades above 
600 MHz, provides == 12 dB sensitivity 
improvement). 

Alternative Reference Level Units - 

dBm, dBmV, dBV, dBpV, dBpW, dBpV/m. 
User-definable Power-on Status - 

Instrument powers up to user-definable state 
or factory default condition. 

Center Measure - Signal Is centered with fre- 
quency and peak amplitude automatically read 
out (not a marker mode). The signal is counted 
in the 2712 or 2711 with Option 02. 

Signal Track - Drifting signal is kept at display 
center with correct frequency and peak ampli- 
tude displayed. 

Graticule Illumination - For CRT photogra- 
phy in analog display mode. 

Supports Epson FX and LQ Series Printers via 
built-in GPIB interface (Std. 2712, 2711 Opt. 03), 
RS-232C interface (Opt. 08, 2712 and 2711). 

Typical but non-warranted performance 
parameters. 

Up to 108 saved displays. 36 front-panel 
setups available with Opt. 03 or 08. 



196 SPECTRUM ANALYZERS 



www.tektronix.com/Measurement/commtest/ 





Spectrum Analyzers 

2712 >2711 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



2712 

Spectrum Analyzer. 

Includes: Power Cord (U.S. 115 V/60 Hz), User's 
Manual, Pocket Reference Guide, Programmer's 
Manual, Front Cover and N-to-BNC Adapter. 

2711 

Spectrum Analyzer. 

Includes: Power Cord (U.S. 115 V/60 Hz), User's 
Manual, Pocket Reference Guide, Front Cover and 
N-to-BNC Adapter. 

Opt. 02 - (2711 only) Add Internal Frequency 
Counter with selectable 1 kHz/1 Hz readout resolution. 
Opt. 03 - (2711 only) GPIB Interface. Full 
Programmability, Direct Print, additional NV RAM 
and Real-time Clock. Cannot combine with Opt. 08. 
Opt. 04 - Add Internal Tracking Generator, 100 kHz 
to 1800 MHz, 0 dBm to -48 dBm in 0.1 dB steps. 

(Not compatible with 2712 Opt. 12 or 14 - order 
External Tracking Generator Opt. 05 instead.) 

Opt. 05 - External Tracking Generator with Active 
Probe Power Jack. Not compatible with Opt. 04. 

Opt. 07 - Add 2704 Inverter/2705 Battery Pack. 

Opt. 08 - (2712 only) Replace GPIB with 
RS-232C Interface. 

Opt. 08 - (2711 only, not compatible with Opt. 03.) 
RS-232 Interface, Full Programmability, Direct Print, 
additional NV RAM and Real-time Clock. 

Opt. 10 - Video Monitor Mode. 

Opt. 12 - (2712 only) Add Quasi-peak Detector 
(built-in). Including 200 Hz, 9 kHz and 120 kHz EMC 
Filters; 1 kHz and 1 MHz RBW Filters. Not compatible 
with Opt. 04 or 14. Note: 200 Hz EMC Filter replaces 
standard 300 Hz RBW Filter. 

Opt. 14 - (2712 only) Add 1 kHz, 10 kHz, 

100 kHz and 1 MHz RBW Filters. Not compatible with 
Opt. 04 or 12. 

Opt. 15 - 1st LO output for use with Tektronix 1405 
TV Sideband Adapter Interface or 2707 Internal 
Tracking Generator. 

Opt 20 - EMC Antenna Set plus Tripod and Coax 
suitable for tests to 1 GHz (contact Tektronix sales 
engineer for more information). 

Opt 21 - Add 2706 Stepping RF Preselector. 

Opt 30 - Rackmount for 19 in. rack width, 

5.25 in. height. 

Opt 33 - Travel Line Package, including Accessory 
Pouch, Carrying Strap, Vinyl Rain Cover. 

Opt. 34 - Portable-to-Rackmount Adapter for 
19 in. rack width, 7 In. height. 



INTERNATIONAL POWER PLUGS 
Opt. A1 - Universal Euro 220 V, 50 Hz. 

Opt A2 - United Kingdom 240 V, 50 Hz. 

Opt. A3 - Australian 240 V, 50 Hz. 

Opt. A4 - North American 240 V, 60 Hz. 

Opt. A5 - Switzerland 220 V, 50 Hz. 

See page 619 for description. 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of Calibration Services. 

Opt. D3 - Test data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover 
three years. 

EMI Ancillary Devices - See page 255. 

ADDITIONAL ACCESSORIES 

Also see page 495. 

PROBES 

Active - All require 1103 Power Supply. 4 GHz, 

0.4 pF/100 ka 1 m. Order P6217. 750 MHz, 2 pF/1 
Ma, 1.5 m. Order P6205. TEKPROBE^ Power Supply. 
Order 1103. 

Power Splitter - 75 Q/50 Q BNC Output, 

50 a BNC Input. Order 067-1232-00. 

CABLES, PADS AND ADAPTERS 
50 Q Coaxial Cable - 

BNC to BNC, 5.5 in. Order 012-0214-00. 

BNC to BNC, 18 in. Order 012-0076-00. 

BNC to BNC, 42 in. Order 012-0057-01. 

75 Q to 50 12 Minimum Loss Adapter - 

With DC block, 5.7 dB loss. Order 131-4199-00. 

75 Q BNC to 50 Q Type N Minimum Loss 
Attenuator - Order 131-4199-00. 

75 Q to 50 Q Matching Attenuator - 
With 11.25 dB conversion factor from dBm 
to dBV with DC block. Order 011-0118-00. 

BNC Female to "F" Male Adapter - 
Order 103-0158-00. 

"N" Female to BNC Male Adapter - 

Order 103-0058-00. 

75 12 to 50 Q Matching Transformer - 

0.5 dB loss. 50 kHz to 300 MHz. Order 120-1883-00. 

5 MHz to 1 GHz. Order 120-1884-00. 

User's Manual - 
2712. Order 070-8137-00. 

2711. Order 070-5800-00. 



Service Manual - 

2712. Order 070-8130-01. 

2711. Order 070-8130-01. 

Front Panel Cover - Order 200-2520-00. 

Transit Case - Order 016-0792-02. 

Soft Side Case - Order 016-1158-01. 

Rain Cover - Order 200-2500-00. 

Accessory Pouch - Mounts on top. 

Order 016-0677-03. 

Carrying Strap - Order 346-0199-00. 

Viewing Hoods - Binocular. Order 016-0566-00. 
CRT Filter - Smoke Grey. Order 337-2775-02. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

C€ 

ISO 9001 

Tektronix measurement products are manufactured 
in ISO registered facilities. 




Product(s) complies with IEEE Standard 488.1-1987. 



www.tektronix.com/Measureiiient/comiiitest/ 



SPECTRUM ANALYZERS 



197 








Features - Benefits Applications 



2704/2705 Field Maintenance 

Easy Connection to Tektronix 27 IX Remote Operation 

Family Spectrum Analyzers 

1 1 5 W of AC Power 

Continuous Power Using 
Sequential Battery Packs 

Lightweight Single Package for Easy 
One-handed Carrying 

Automatic Charging of Two Battery 
Packs Simultaneously 

Auxiliary 18 V DC LNB Power 
Low Battery Warning 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1 - 503 - 627 - 1916 , 
inside the U.S. call: 
1 - 800 - 426 - 2200 . 

C€ 



|g ISO 9001 

Tektronix measurement 
products are manufactured in 
ISO registered facilities. 



2704 lNVERTER/2705 Battery Pack 

The 2704 Inverter and 2705 Battery Pack can 
provide for operation of 271X spectrum analyz- 
ers in locations where AC power is not available. 
These units mount directly on the spectrum ana- 
lyzer to form a portable package. 



Several 2705s can be used to provide an uninter- 
ruptible power source for the spectrum analyzer 
or other equipment. The 2704 includes a battery 
charger, and provides an auxiliary 18 volt out- 
put. The 2704 also accepts 12 volt input from 
other sources, such as car batteries. These units 
are described in more detail in the Inverter/ 
Battery Pack Data Sheet. 



Ordering Information 



For price information: 

Outside the U.S. contact your local Tektronix representative, 

2704 

Inverter. 

Includes: Power Cord (U.S. 115 V, 60 Hz), Operator's Manual, 
Analyzer Mounting Plate. 

Opt. R3 - Repair warranty extended to cover three years. 

Opt. R5 - Repair warranty extended to cover five years. 

2705 

Battery Pack. 

1.5 Meter DC Power Cord - 2704 Inverter-to-Automotive 
Cigarette Lighter Plug. Order 118-8549-00. 

1.5 Meter DC Power Cord - 2704 Inverter-to-Alligator Clips. 
Order 118-8550-00. 



inside the U.S. see the price list in the back of this catalog. 

INTERNATIONAL POWER PLUGS 
Opt. A1 - Universal Euro 220 V, 50 Hz. 

Opt. A2 - United Kingdom 240 V, 50 Hz. 

Opt. A3 - Australian 240 V, 50 Hz. 

Opt. A4 - North American 240 V, 60 Hz. 

Opt. AS - Switzerland 220 V, 50 Hz. 

See page 619 for description. 



198 SPECTRUM ANALYZERS 



www.tektronix.com/Measurement/commtest/ 






Tracking Generators 

2707 • 2711/2712 Opt. 04 • Opt. 05 




Features - Benefits 



2707 External Tracking Generator 
(271 X Opt. 05) for 271 1 and 2712 

Internal Tracking Generator for 
2711 and 2712 (Opt. 04) 

Swept Measurements 100 kHz to 
1.8 GHz 

Output from -48 dBm to 0 dBm 
(-1.2 dBmV to 46.8 dBmV) in 
0.1 dB Steps 

Frequency Offset Capability 



Applications 



CATV - Check Filters, Amplifiers 
and Cables 

EMI - Site Attenuation Tests, Filter 
Design, Isolation Checks and 
Verifying Cable Flatness 

Broadcast - Check Traps and Filters 

Communications Radio 
Maintenance - Tune Duplexers, 
Check Antennas 



The 2707, 2711/2712 Option 04 (internal) and 
2711/2712/2715 Option 5 (external) tracking 
generator systems provide swept measurements 
from 100 Hz to 1.8 GHz and at least 100 dB 
dynamic range to see filter, ultimate rejection or 
circuit isolation characteristics. 

^180 9001 

Tektronix measurement 
products are manufactured in 
ISO registered facilities. 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1 - 503 - 627 - 1916 . 
inside the U.S. call: 
1 - 800 - 426 - 2200 . 

Cf 



Internal and External 
Tracking Generators 

Characterize filters, check duplexers or cables, 
make frequency response, SWR measurements 
(with a return-loss bridge), EMI site attenuation 
tests - all this and much more. 



Ordering Information 



For price information: 

Outside the U.S. contact your local Tektronix representative, 

2707 

External Tracking Generator. 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of Calibration Services. 

Opt. D3 - Test Data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover three years. 



inside the U.S. see the price list in the back of this catalog. 

2711/2712/2715 OPT. 05 

External Tracking Generator. 

Includes: Power Cord, 50 Q SMA Cable, Type N Male-to-BNC 
Female Adapter, 15-Pin Male-to- 15-Pin Male High Density D-sub 
Cable Assembly. Mounting Bracket with Mounting Hardware, 
Trim Strips, Instruction Manual. 

Opt. 01 - 75 Q output. 

2711/2712 Opt. 04 Internal Tracking Generator. 

See page 197 for more information. 



www.tektronix.com/Measurement/commtest/ 



SPECTRUM ANALYZERS 199 






N ETWORK Analyzers 



Contents 



ZVRL 201 

ZVRE51 201 

ZVRE52 201 

ZVR61 201 

ZVR62 201 

ZVCE 201 

ZVC 201 

R3765AH 207 

R3765BH 207 

R3765CH 207 

R3767AH 207 

R3767BH 207 

R3767CH 207 

R3754A 211 

R3754B 211 



For Production Test 

Network analyzers can be used to characterize a variety of devices, from components 
and materials to circuits, equipment, and systems. They can he used effectively even 
when individual components or test points cannot he accessed. Network analyzers 
measure the transmission and reflection characteristics of linear circuit networks by 
applying a sine wave to the input of the device-under-test (DUT) and measming the 
resultant signals at the output. The most accurate way to analyze linear circuit net- 
works is to measure the amplitude and phase versus frequency of circuit network 
transmission and reflection characteristics at various frequencies. Knowing these 
relationships provides the information required to characterize the behavior of linear 
networks quickly, accurately, and completely over a hroad frequency range. 



200 



NETWORK ANALYZERS 



www.tektronU.com/Measurement/comintest/ 




ZVR Family of Vector Network 



Analyzers 



New Network Analyzers 

seven models for all REQUIREMENTS: ZVRL, ZVRE51, ZVRE52, ZVR61, ZVR62, ZVCE. ZVC 




Features - Benefits Applications 



Excellent Dynamic Range 
->130 dB (IF Bandwidth 10 Hz) 

Low Inherent Noise 
-<-110 dBm (IF Bandwidth 
3 kHz) 

Broad Frequency Range for 
Universal Use 

- 10 Hz to 4 GHz (ZVRU ZVRE, ZVR) 
-20 kHz to 8 GHz (ZVCE, ZVC) 

High Measurement Speed 
-<125 ps/point (Normalized) 
-<240 ps/point (Fully Calibrated) 

Fast Data Transfer via I EC/IEEE Bus 
-Transfer Time <30 ms 
(200 Points) 

Manual Calibration Techniques 
-TOM, TRM, TRL, TNA, TOM-X 

Automatic Calibration 
-AutoKal 



RF and Wireless Communications 
Satellite Broadcasting Equipment 
Component Test 
Subsystem Test 
Manufacturing Test 
Automated Test 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 



1^1809001 



Tektronix measurement 
products are manufactured in 
ISO registered facilities. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



Innovation for Versatility, Speed 
AND Accuracy 

A FAMILY FOR EVERY REQUIREMENT 

The vector network analyzers of the ZVR family 
from Rohde&Schwarz have set standards for 
extremely fast, highly accurate and versatile 
test equipment. 

The family comprises the seven Vector Network 
Analyzers ZVRL, ZVRE51, ZVRE52. ZVR61 and 
ZVR62 as well as ZVCE and ZVC which extend 
the frequency range to 8 GHz. All models are 
compact instruments with integrated generator, 
test set and receiver, each tailored to a different 
field of application. 



Thanks to the great variety of options and test 
sets, the analyzers can be tailored even to very 
special kinds of measurement tasks. 

In contrast to a passive test set an active test set 
contains a bias network, e.g. for supplying 
active DUTs. 

Design 

With a unidirectional analyzer only measure- 
ments in the forward direction can be performed. 

With a bi-directional analyzer all four S-parame- 
ters of the DUT can be determined without 
changing connections. 

The 4-channel analyzers provide calibration 
methods like TOM. TRM. TRL and TNA. 



www.tektronix.cofn/Measurement/comintest/ 



NETWORK ANALYZERS 201 








ZVR Family of Vector Network Analyzers 

NEW NETWORK ANALYZERS 



300 kHz 4 CRi 




9 kHz 4 GHz 



ZVR. ZVBE. ZVn. (passivR ttst set) 



10Hz 4 6Hz 



ZVR, ZVK. ZVRl (SflUi Eit. Heaswenents option) 



20 kHz 8 6Hz 



ZVC,ZVCE{sethe test set) 






ieHzto4GHior20kHzto8 6Hz 


...... 


<125uS^olnI 





>13ett(IFtnadwliltli 10H2) 


<aitkni(ien nelKMb 


. . . . JtataKat. TOM, TRM. TRL, TNA. TIM-X 


ilieiiEI-ltK nHR«we ttiies . 


. . . RraHat UiM <30 ms (200 test points) 



The Highlights in Brief 

THREE TIMES TOP SPEED 

High Sweep Rate 

The high measurement speed allows 
more than 25 sweeps/s with 200 points. 
This gives a real analog feeling for tun- 
ing sensitive DUTs in real time. The 
short measurement time of <125 ps per 
point considerably increases the 
throughput in automatic test systems. 




ZVRL (unidirectional) 




ZVRE, ZVCE (bidirectional, 3 channels) 



Fast lEC/IEEE Bus 

Reading out a single marker value via the 
lEC/IEEE bus takes only 15 ms, reading 
out complete trace data (200 values) less 
than 30 ms, which speeds up complex, 
computer-controlled measurements. 

Short Calibration Times 

With the new R&S calibration method 
AutoKal a simple through-connection of 
the test ports is sufficient to perform auto- 



Comparison of the Models 



Model 


ZVRL 


ZVRE 


ZVR 


ZVCE 


ZVC 


Test set 


unidirec- 

tional 


bidirectional 


Receiver channels 


3 


3 


4 


3 


4 


Broad frequency range 


10 Hz*'' to 4 GHz 


20 kHz to 8 GHz 


Wide dynamic range*^ 


>125 dB 


>125 dB 


>130 dB 


>125 dB 


>130 dB 


High sensitivity*^ 


<-125 dBm 


<-125 dBm 


<-130 dBm 


<-125 dBm 


<-130 dBm 


High measurement speed 


<125 |iS/point 


Fast lEC/IEEE bus*^ 


< 15 ms 


High frequency resolution 


lOpHz 


Short calibration times*^ 


<20s 


Large display 


Active 26 cm colour LCD 




ZVR, ZVC (bidirectional, 4 channels) 



With External Measurements option. 

From marker request to data output (real and imaginary' values). 
Automatic two-port calibration with AutoKal. 



matic full two-port calibration. This cali- 
bration needs less than 20 seconds 
(including computation of error parame- 
ters) and cuts time and operating errors to 
a niinimum. Short measurement time of 
<125 ps per point considerably increases 
the throughput in automatic test systems. 

ZVRL - THE LEAN MODEL 

ZVRL comprises a test set with one 
SWR bridge, two measurement chan- 
nels and a reference channel for meas- 
uring the magnitude and phase of the 
forward S-parameters and S 21 . 

ZVRE AND ZVCE - THE ECONOMY 
MODELS 

The test set of these models comprises 
two SWR bridges (ZVRE) or directional 
couplers (ZVCE), an RF switch, two 
measurement channels and one refer- 
ence channel. They measure the magni- 
tude and phase of all four S-parameters 
of a DUT, allow a full two-port calibra- 
tion (TOSM) and have an exceptionally 
high accuracy and wide dynamic range. 

ZVR AND ZVC - THE UNIVERSAL 
MODELS 

ZVR and ZVC comprise a test set with 
two SWR bridges (ZVR) or directional 
couplers (ZVC), an RF switch, two meas- 
urement channels and - imlike ZVRE 
and ZVCE - two reference channels. 
With this configuration a variety of novel 
calibration procedures, e.g. TNA, can be 
performed, which considerably improve 
the accuracy particularly in non-coaxial 
applications. ZVR and ZVC are suitable 
for applications in R&D and production 
no matter how sophisticated. 




Bandpass filter. 



202 NETWORK ANALYZERS 



www.tektronix.com/Measurement/commtest/ 




ZVR Family of Vector Network Analyzers 

NEW NETWORK ANALYZERS 



Technical Details 

SPEED »25 SWEEPS/S 

An efficient transputer system and the 
extremely fast synthesizer give high 
sweep rates. The result is a ’’quasi-ana- 
log" measurement trace with full error 
correction and high frequency accuracy. 
The dynamic range at the maximum 
sweep rate is 80 dB for the full meas- 
urement bandwidth of 26 kHz. 

DYNAMIC RANGE >130 DB 

The high stopband and low passband 
attenuation of modern RF components 
are difficult for network analyzers to 
handle. However, thanks to fundamen- 
tal mixing, the useful dynamic range of 
the R&S network analyzers is more than 
25 dB better than that achieved by con- 
ventional sampling techniques. Because 
of the low-noise front end, the ZVR 
models attain a dynamic range of >130 
dB, so transmission measurements on 
DUTs with extremely high stopband 
attenuation can be performed at high 
speed - even at low input levels. 

POWER CALIBRATION: TESTING 
ACTIVE DUTS 

Power calibration performed at the test 
ports in the factory ensures constant 
output power and high accuracy in the 
measurement of absolute input power 
over the full frequency range. This is 
particularly important for firequency- 
converting and nonlinear measurements 
on active components. Furthermore, 
with the aid of the Power Calibration 
option frequency-dependent level varia- 
tions of an external test setup can be 
measured and compensated for. 

SIMULTANEOUS DISPLAY OF FOUR 
TRACES ON THE 26 CM COLOR LCD 

The ZVR models are the first network 
analyzers in this price class to simulta- 
neously display four measurement traces 
with independent parameters (measured 




Quad-channel display. 



quantity, frequency range, bandwidth, 
etc). The high-resolution, active, color 
LCD with a high refresh rate allows pre- 
cise alignments without operator fatigue. 

INTEGRATED CONTROLLER 

When equipped with the Controller 
option, the network analyzer can be used 
as a PC. The option comprises an addi- 
tional VGA card, a memory expansion, a 
serial mouse and a keyboard. DOS 6.22 
and Windows 3.1 are included. 

AUTOMATIC TEST SYSTEMS 

Fast recording and processing of meas- 
ured values and, in addition, an SCPI- 
conform lEC/lEEE-bus command set 
make all models of the ZVR family 
ideal for use in automatic measurement 
systems. When equipped with the 
Controller option and a second lEC/ 
lEEE-bus card, the analyzers can be 
used as system controllers. As a result, 
fewer instruments are required; this 
saves space in the system rack. LAN 
connections can be set up with the 
Ethernet option. 

EFFICIENT CALIBRATION TECHNIQUES 

The classic 12-term calibration method 
requires four calibration standards, i.e., 
Through, Open, Short and Match. The 
abbreviation TOSM used for this 
method is derived from the standards 



names. ZVR and ZVC also provide a 
number of other modern calibration 
methods (TOM, TRM, TRL, TNA). 
Unlike TOSM (12-term), they require 
only three different standards. 
Additionally, Lines (L), unknown 
Reflects (R), matched Attenuators (A) 
and symmetrical two-port Networks (N) 
can also be used. Due to its simplicity, 
TOM is the recommended method and 
should therefore be used for general 
applications. To perform a calibration, 
the two test ports are directly connect- 
ed (Through) and an open-circuit 
(Open) and a matched load (M atch) 
have to be connected to each test port. 
For frequencies up to only a few 100 
MHz, it is not necessary to connect an 
open circuit, the ports may simply be 
left open. Thus a complete two-port cal- 
ibration can be performed with only 
two different calibration standards. 

High accuracy can be obtained with a 
minimum of effort using the AutoKal 
option to which only the Through stan- 
dard has to be connected. 




Fig. 1. 




Measurement and IEC/IEEE-bus speed of network analyzers 

Number of test points 

Measurement Times (Fast Mode) 51 201 401 

Normalized unidirectional ind retrace sweep, 5 ms 10 ms 30 ms 60 ms 

Two-port calibrated bi-dire ct i o nal 20 ms §0. .rps 100 nis 



IEC/IEEE-bus Data Tran 

Time between sending the request and availability of data 

ASG| 

IEEE-754 floating-point format 

(setting data 64-Bit, measurement data 32-Bit) 



40 ms 
20 ms 



90 ms 
30 ms 



160 ms 
40 ms 



www.tektronix.com/Measurement/commtest/ 



NETWORK ANALYZERS 203 




ZVR Family of Vector Network Analyzers 

NEW NETWORK ANALYZERS 




Fig. 3. 




Fig. 4. 

Applications 



FILTER MEASUREMENTS (1 TO 4) 

For accurate transmission and reflection 
measurements on narrowband DUTs 
such as resonators and filters, a stable 
generator with high frequency resolu- 
tion and a receiver with wide dynamic 
range and high measurement accuracy 
are required. The analyzers of the ZVR 
family are ideal for such measurements. 

Special band-filter evaluation functions 
(1) minimize the time required for 
checking and tuning filters. Important 
filter data such as bandwidth, center 
frequency, Q and shape factor are dis- 
played at a keystroke. Marker tracking 
functions provide actual information on 
amplitude and frequency in real time 
during DUT adjustment. User-defined 
frequency and scale segments (2) sim- 
plify and speed up evaluation of select- 
ed subranges of a sweep. 

Fully arbitrary zoom even in the Smith 
chart allows the user to concentrate on 
the interesting part of the trace (3 and 4). 



AMPLIFIERS AND MIXERS (5) 

For measuring active components fea- 
turing high gain and high isolation, a 
wide dynamic range as well as high sen- 
sitivity and isolation of measurement 
channels are required. In addition to S- 
parameters and derived quantities, non- 
linear parameters can also be measured: 

► Magnitude of 2nd and 3rd harmonics 

► n dB compression point 

► IP 2 and IP 3 

These parameters can also be displayed 
versus frequency. 

Due to the use of two independent syn- 
thesizers for generator and receiver and 
the ability to control two external gen- 
erators, a variety of measurements can 
be performed at full speed on frequen- 
cy-converting DUTs, e.g., mixers. 

Thanks to the special receiver principle 
used by R&S analyzers, add-ons like fil- 
ters are not required for the suppression 
of spurious. 

Comparison of full two- 
port CALIBRATION PROCEDURES 

By using four instead of three receiver 
channels, ZVR and ZVC unlike ZVRE 
and ZVCE can provide additional pow- 




Fig. 5. 




erful calibration methods, e.g., TOM, 
TRM, TNA and the 15 -term method 
TOM-X (X = crosstalk), e.g., for “on- 
wafer” measurements. 



Full two-port 

calibration 

procedures 


Number of 
calibration 
steps 


Special 

feature 


TOM 


5 


implicit verification 


TRM 


5 Especially for test fixtures 


TRL 


4 


High directivity 


TNA 


3 Esp 


lecially for planar circuit 


TOSM 


7 


Classic procedure 


TOM-X 




Eliminates crosstalk 



COMPATIBLE WITH CAE TOOLS 

When developing circuits on the com- 
puter with the aid of CAE tools, it is 
essential for the S-parameters measured 
on a DUT to be transferred to the respec- 
tive CAE program. Measured S-parame- 
ters are stored on a floppy in a CAE-tool- 
compatible format and ready for direct 
processing by simulation programs. 

AF MEASUREMENTS 

The External Measurements option 
extends the frequency range of ZVRL, 
ZVRE and ZVR down to 10 Hz, for 
instance for audio applications, and 
increases the sensitivity and output 
power of all analyzers. 

MEASUREMENTS ON DUPLEX 
FILTERS (5) 

Duplex filters, which are widely used in 
mobile radio, need simultaneous meas- 
urement and adjustment on several sig- 
nal paths in real time. With the aid of the 
3-Port and 4-Port Adapter options, sever- 
al passband characteristics, e.g., those of 
the TX and RX path, can be displayed 
quasi-simultaneously. All measurement 
paths can be calibrated independently. 

MEASUREMENTS ON PULSED 
SIGNALS (6) 

In the field of mobile radio it is impor- 
tant to know the transient response 
when an amplifier is turned on or off. 
Due to attractive features such as: 

► Up to five measmrements within a 
GSM burst 

► External trigger capabilities. 

The analyzers are able to measure 
the magnitude and phase even of 
pulsed signals. 



204 NETWORK ANALYZERS 



www.tektronix.com/Measurement/coinfntest/ 







ZVR Family of Vector Network Analyzers 

NEW NETWORK ANALYZERS 



System Configuration 





Test cables and calibration kit (type N). 



TEST SETS 

The network analyzers can be provided 
with different test set options so that an 
optimally configured test setup is avail- 
able to suit the applications. 

For the 4 GHz analyzers “active” or 
“passive” test sets with a characteristic 
impedance of 50 Q or 75 ^2 are avail- 
able. A 50 Q passive test set is standard 
equipment. With active test sets, the 
OUT can be biased directly via the 
inner conductor of the test port. The 8 
GHz models ZVCE and 7NC are always 
equipped with 50 ^2 active test sets. 

Depending on the model, the test sets 
comprise one or two power splitters, an 
electronic switch and one or two SWR 
bridges or directional couplers. 
Additional step attenuators (0 dB to 
70 dB) can be inserted into the genera- 
tor paths and the two measurement 
channels to extend the power range of 
the receivers to +27 dBm. 

When the test sets are fitted with atten- 
uators and the External Measurements 
option, generator and receiver can be 
directly switched to three additional 
ports on the front panel (OUTPUT al, 
INPUT bl, INPUT b2). This increases 
output power, sensitivity and dynamic 
range, and measurements down to 
10 Hz can be performed with the 4 GHz 
models. The test ports are fitted with 
female N connectors. 





CALIBRATION AND VERIFICATION KITS 

The accuracy of a calibrated network 
analyzer is determined by the quality of 
the calibration standards and the repro- 
ducibility of connections. 

Rohde&Schwarz offers accessories for 
all common connector types for the cal- 
ibration and verification of network 
analyzers. 

The calibration kits include the required 
standards for TOSM (12-term) or TOM 
calibrations. Standards with male and 
female connectors are supplied. Sliding 
loads are also available. Supplementary 
calibration kits for the TRL and TOM-X 
methods can also be supplied. 

The quality of the calibration method 
and so the measurement accuracy of the 
network analyzer system can be checked 
with precise verification standards. 

Each verification kit includes a 20 dB 
attenuator, a 40 dB attenuator and two 
air lines, one of them with impedance 
steps (Beatty standard). 



www.tektronix.com/Measurement/commtest/ 



N ETWORK ANALYZERS 



205 





ZVR Family of Vector Network Analyzers 

NEW NETWORK ANALYZERS 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



ZVRL - 3-channel, unidirectional, 50 a, passive, fre- 
quency range 9 kHz to 4 GHz. 

ZVRE51 - 3-channel, bi-directional, 50 Q, passive, 
frequency range 9 kHz to 4 GHz. 

ZVRE52 - 3-channel, bi-directional, 50 Q, active, 
frequency range 300 kHz to 4 GHz. 

ZVR61 - 4-channel, bi-directional, 50 n, passive, 
frequency range 9 kHz to 4 GHz. 

ZVR62 - 4-channel, bi-directional, 50 Q, active, fre- 
quency range 300 kHz to 4 GHz. 

ZVCE - 3-channel, bi-directional, 50 Q, active, fre- 
quency range 20 kHz to 8 GHz. 

ZVC - 4-channel, bi-directional, 50 Q, active, fre- 
quency range 20 kHz to 8 GHz. 

ALTERNATIVE TEST SETS* 

ZVRA71 - 75 Q passive SWR Bridge for ZVRL 
(Instead of SWR bridge, 50 Q passive)*’, frequency 
range 9 kHz to 4 GHz. 

ZVRA75 - 75 Q passive Bridge Pairs for ZVRE and 
ZVR (Instead of bridge pairs, 50 Q )*’, frequency 
range 9 kHz to 4 GHz. 

ZVRA76 - 75 12 active Bridge Pairs for ZVRE and 
ZVR (Instead of bridge pairs, 50 Q )*’ frequency 
range 300 kHz to 4 GHz. 

OPTIONS 

Opt. B1 - AutoKal, frequency range 0 to 8 GHz. 
Opt. B4 - Mixer Measurements*^ frequency range 
same as analyzer. 

206 NETWORK ANALYZERS 



Opt. B5 - Non-linear Measurements, frequency 
range same as analyzer. 

Opt. B6 - Reference Channel Ports, frequency range 
same as analyzer. 

Opt. B7 - Power Calibration*^ frequency range 
same as analyzer. 

Opt B8 - 3-Port Adapter, frequency range 0 to 4 GHz. 
Opt. K9 - Virtual Embedding Networks*^ 

Opt B1402 - 4-Port Adapter (2 x SPOT), frequency 
range 0 to 4 GHz. 

Opt B1403 - 4-Port Adapter (SP3T), frequency 
range 0 to 4 GHz. 

Opt. BIS - Controller (English)*^ 

Opt. B16 - Ethernet AUl for FSE-B15. 

Opt. B17 - EC/IEEE-Bus Interface for ZVR-B15. 

Opt. B21 - Generator Step Attenuator PORT 1, fre- 
quency range same as analyzer. 

Opt. B22 - Generator Step Attenuator PORT 2*^ 
frequency range same as analyzer. 

Opt. B23 - Receiver Step Attenuator PORT 1, fre- 
quency range same as analyzer. 

Opt. B24 - Receiver Step Attenuator PORT 2, fre- 
quency range same as analyzer. 

Opt. B25 - External Measurements 50 12*^ fre- 
quency range 10 Hz to 4 GHz (ZVR/^L), frequency 
range 20 kHz to 8 GHz (ZVC/E). 



Test Cables (Pairs) - 
ZV-Z11 - N connector, 50 Q male, 
frequency range 0 to 18 GHz. 

Calibration Kits - 
ZV-Z21 - N connector, 50 12, 
frequency range 0 to 18 GHz. 

ZV-Z23 - PC 3.5, frequency range 0 to 26.5 GHz. 
ZV-Z26 - TRL Suppl. Kit, N, 50 12, frequency range 
0.4 GHz to 18 GHz. 

ZV-Z27 - TRL Suppl. Kit, PC 3.5, frequency range 
0.4 to 26.5 GHz. 

ZV-Z28 - TOM-X Suppl. Kit, N, 50 12, frequency 
range 0 to 18 GHz. 

ZV-Z29 - TOM-X Suppl. Kit, PC 3.5, frequency range 
0 to 26.5 GHz. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 



ISO 9001 

Tektronix measurement products are manufactured 
in ISO registered facilities. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



www.tektronlx.com/Measurenient/commtest/ 




Network Analyzers 

R3765AH/BH/CH • R3767AH/BH/CH 




Features - Benefits 



40 MHz to 3.8 GHz Measurement 
Frequency Range (R3765) 

40 MHz to 8.0 GHz Measurement 
Frequency Range (R3767) 

Three Models Available: 

-Type A Basic Model 
-Type B with Built-in SWR Bridge 
-Type C with Built-in S-Parameter 
Test Set 

High Sweep Speed 
-0.10 ms/point with Normalized 
Calibration 

-0.20 ms/point with Two-port 
Full Calibration 



Applications 



High-speed Automated Test 
RF and Wireless Communications 
Satellite Broadcasting Equipment 
Component Test 
Manufacturing Test 
Test Program Development 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 

C€ 




Product(s) complies with IEEE 
Standard 488.1-1987, 
and with Tektronix Standard 
Codes and Formats. 

/IDVANTEST 

Advantest's quality system 
complies with the 
DIN ISO 9002 standard and 
has been certified by TUV 
Product Sen/ice GMBH. 



The R376xxH Network Analyzers feature unprece- 
dented measurement speed and productivity 
enhancements. The R3765 analyzer covers the fre- 
quency range from 40 MHz to 3.8 GHz; the R3767 
extends the upper frequency limit to 8 GHz. These 
analyzers are designed specifically for testing com- 
ponents in the rapidly expanding field of RF and 
wireless communications (cellular phones, pagers, 
cordless phones, etc.). 

HIGH THROUGHPUT WITH RELIABLE 
MEASUREMENT 

The R376xxH Provide high throughput and high- 
ly reliable measurement. They achieve high- 
speed measurement (0.1 ms/point at 10 kHz 
RBW), wide dynamic range measurement 
(100 dB), two device simultaneous measurement 
with 4-channel 8-trace function and other useful 
functions. Besides a conventional frequency 
sweep function, several new concepts have been 
added. First, a program sweep function allows 
the user to freely change resolution bandwidth 
or output level at any point during the sweep. 
Second, a high-speed level sweep uses a new 
semiconductor switch at the output section and 
is ideal for drive level performance testing of 
quartz oscillators. 



STAND ALONE MEASUREMENT FEATURES 

The R376xxH are designed for stand alone 
benchtop use and high-speed ATE system appli- 
cations. They feature a TFT (thin film transistor) 
color liquid crystal display for measurement 
results. This flat-panel display enhances visibili- 
ty and operability which are important for inter- 
preting and analyzing the results of measure- 
ments (such as data comparison and pattern 
recognition). 

On-screen menus and soft keys provide access to 
a wide variety of routines for both transmission 
and reflection measurements. These include dis- 
plays of magnitude, phase, group delay, SWR, 
Smith Charts or combinations of these. 

BUILT-IN CONTROLLER FUNCTION 

The R376xxH have a built-in BASIC controller 
function for configuration of a high-speed ATE 
system without using an external controller. A 
3.5 in. MS-DOS compatible 1.44 MB floppy disk 
drive is also standard. This allows programs to 
be written on a PC-compatible controller and 
easily ported to the network analyzer. 



www.tektronix.com/Measurement/conimtest/ 



NETWORK ANALYZERS 207 







Network Analyzers 

R3765AH/BH/CH • R3767AH/BH/CH 



POWERFUL 4-CHANNEL/8-TRACE 
FUNCTION WITH SIMULTANEOUS 
DISPLAY 

The R376xxH provide 4-channel/8-trace 
function with simultaneous display 
capability. For example, when a 3-port 
test adapter is connected to the 
R376xxH, simultaneous and real-time 
measurement of Tx/Rx characteristics 
of the duplexer is possible. Channels 1 
and 3 measure four S-parameters of Tx 
and channels 2 and 4 measure those of 
Rx at the same time with a throughput 
of approximately 250 ms (with 201 
points and 2-port full calibration). In 
addition, limit lines and multi-marker 
functions can be used for each of the 
four screens. 

HIGH THROUGHPUT AND HIGH 
RELIABILITY 

Total throughput is one of the most 
important characteristics of an electron- 
ic component measurement system. 
Among many factors, sweep rate has 
the greatest influence on total through- 
put. The R376xxH achieve a 0.1 
ms/point sweep rate (at 10 kHz RBW). 
The R376xxH realizes the highest 
throughput in its class. 

100 DB DYNAMIC RANGE FOR FILTER 
TEST 

For spurious checks in stop band, 
measurement with a wide dynamic 
range is crucial. The R376xxH realize 
100 dB dynamic range with 10 Hz reso- 
lution bandwidth, making it suitable for 
testing of high-attenuation devices used 
in base stations or portable phones. 

PROGRAMMED SWEEP REALIZES 
HIGH-SPEED AND HIGH-RESOLUTION 
MEASUREMENTS 

The R376xxH have a programmed 
sweep function which makes it possible 
to vary output power and resolution 
bandwidth (RBW) during a sweep. In 
evaluation of filter characteristics, for 
example, measurement with high 
speed, high accuracy, and high repro- 
ducibility can be realized by varying 
resolution bandwidth and output power 
within the pass band or stop band. 



208 NETWORK ANALYZERS 



LIMIT LINE FUNaiON FOR 
ADJUSTMENT AND TEST 

The limit line function performs 
PASS/FAIL tests based on the judgment 
value set by the limit line editor. It then 
displays the test result. In addition, the 
color of the limit lines and waveform 
data can be specified for each judge- 
ment area, allowing the user to make 
PASS/FAIL decisions at a glance. In 
POLAR and Smith chart measurement, 
the ability to make limits judgements 
both for amplitude and phase allows 
amplitude/phase adjustment for speci- 
fied frequency ranges with automatic 
test result. 



Characteristics 



MEASUREMENT FUNaiONS 
Sweep Channel - 2 channels (CH 1 and CH 2). 
Display Channel - 4 channels (CH 1, CH 2 , 

CH 3, CH 4). 

Display Parameters - 
Type A: A/R, B/R. 

Type B: Transmission, Reflection, Transmission 
and Reflection. 

Type C: Sll, S21, S22, S12, S21 and Sll, S12 
and 522. 

Format - 

Rectangular Coordinates: Log/linear amplitude, 
phase and group delay, or real part + imaginary 
part of complex parameter |Z|, R, X (at measure- 
ment with Impedance conversion), |Y|, G, B (at 
measurement with admittance conversion). 
Smith Chart: 

Marker reading: Log/linear amplitude, phase, 
real + imaginary part, R +phjX, G + phjB. 

Polar Coordinates: 

Marker reading: Log/linear amplitude, phase, 
real + imaginary part. 



RECEIVER CHARAaERISUCS 
Resolution Bandwidth - 10 kHz to 10 Hz (in 

1 or 3 steps). 

Amplitude Characteristics - 

Amplitude Resolution: 0.001 dB. 

Frequency Characteristics (-10 dBm, 

25®C ±5®C): 1.0 dBm. 

Dynamic Accuracy (with respect to -20 dB 
below maximum input level of test port): 

0 to -10 dB: 

40 MHz <f < 3.8 GHz: ±0.3 dB. 

3.8 GHz < f < 8.0 GHz: ±0.8 dB. 

-10 to -20 dB: 

40 MHz <f < 3.8 GHz: ±0.05 dB. 

3.8 GHz < f < 8.0 GHz: ±0.2 dB. 

-20 to -50 dB: ±0.05 dB. 

-50 to -60 dB: ±0.15 dB. 

-60 to -70 dB: ±0.15 dB. 

-70 to -80 dB: ±0.40 dB. 

-80 to -90 dB: ±1.00 dB. 

Phase Characteristics - 
Measurement Range: ±180® (display of ±180® 
or more is possible with display extension 
function). 

Phase Resolution: 0.01®. 

Frequency Characteristics (-10 dBm, 

25®C ±5®C): ±5®. 

Dynamic Accuracy (with respect to -20 dB 
below maximum input level of test port): 
Oto-IOdB: ±5.0® 

-10 to -20 dB: 

40 MHz <f< 3.8 GHz: ±0.3®. 

3.8 GHz < f < 8.0 GHz: ±0.8®. 

-20 to -50 dB: ±0.3®. 

-50 to -60 dB: 

40 MHz <f < 3.8 GHz: ±0.4®. 

3.8 GHz < f < 8.0 GHz: ±0.8®. 

-60 to -70 dB:±1.5®. 

-70 to -80 dB: ±4.0®. 

-80 to -90 dB: ±8.0®. 

Group Delay Time Characteristics - 
Range: Calculated by the following expression: 
r= (phase) / (360 x aperture frequency (Hz)). 
Measurement Range: 1 ps to 250 s. 

Group Delay Time Resolution: 1 ps. 

Aperture Frequency: Can be set to A x 2% to A 
X 100% for frequency span, with resolution of 
A X 2%: 

A = (100) / (measurement points - 1). 
Accuracy: 

= (phase accuracy) / (360 x aperture frequency 
(Hz)). 



www.tektronix.com/Measurement/commtest/ 





Network Analyzers 

R3765AH/BH/CH • R3767AH/BH/CH 



SIGNAL SOURCE CHARAaERISTICS 
Measurement Frequency - 

Range: 

R3765: 40 MHz to 3.8 GHz. 

R3767: 40 MHz to 8.0 GHz. 

Set Resolution: 1 Hz. 

Measurement Resolution: ±0.005 ppm. 
Accuracy: ±20 ppm (25°C ±5°C). 

Output Level - 
40 MHz to 3.8 GHz: 

Range: 

Type A: +17 dBM to -8 dBm. 

Type B: +7 dBm to -18 dBm. 

Type C: +10 dBm to -15 dBm. 

Resolution: 0.01 dB. 

Linearity (25X ±5X): 

Type A (with respect to +7 dBm): 

+12 dBM to -3 dBm: ±0.4 dB. 

+17 dBM to -8 dBm: ±0.7 dB. 

Type B (with respect to -3 dBm): 

+2 dBM to -13 dBm: ±0.4 dB. 

+7 dBM to -18 dBm: ±0.7 dB. 

Type C (with respect to 0 dBm): 

+5 dBM to -10 dBm: ±0.4 dB. 

+10 dBM to -15 dBm: ±0.7 dB. 

Flatness (Type C at test port, 25®C ±5°C): 

20 dBp-p. 

3.8 GHz to 8 GHz (R3767): 

Type A: -3 dBm or more. 

Type B: -16 dBm or more. 

Type C: -13 dBm or more. 

Output Impedance - 50 Q. 

Signal Purity (at maximum output) - 

Harmonic distortion (40 MHz to 3.8 GHz): 
<20 dBc. 

Non-harmonic spurious (40 MHz to 3.8 GHz): 
<25 dBc. 

Phase noise (10 kHz offset, 1 Hz BW): 

<-85 dBc to 20 log (F/40 MHz). 



SWEEP FUNaiON 

Sweep Parameter - Frequency, signal level. 

Maximum Sweep Range - 

Frequency: 

R3765: 40 MHz to 3.8 GHz. 

R3767: 40 MHz to 8.0 GHz. 

Signal Level: 

Type A: +17 dBm to 8 dBm. 

Type B: +7 dBm to -18 dBm. 

Type C: +10 dBm to -15 dBm. 

Sweep Type (minimum sweep time differs 
according to measurement format, type of 
error correction, sweep width per point, 
number of measurement points, and IF 
bandwidth) - 

Normalized Calibration: 0.15 ms/point. 

2-port Full Calibration: 0.25 ms/poInt. 
Measurement Point - 3, 6, 11, 21, 51, 101, 

201, 301, 401, 601, 801, 1201 points. 

Sweep Trigger - Continuous, hold, single, 
external. 

Sweep Mode - 

Dual Sweep: Sweeps two channel (CH 1 and 
CH 2) with the same frequency range. 

Alternate Sweeps two channels (CH 1 and CH 2) 
with different sweep types and frequency ranges. 

TEST PORT CHARACTERISTICS 
Test Port Load Matching (25*"C iS^'C) - 

0 MHz to 2.6 GHz: 18 dB. 

2.6 GHz to 3.8 GHz: 16 dB. 

3.8 GHz to 8.0 GHz (R3767): 14 dB. 

Directivity (25®C ±5®C) - 
40 MHz to 2.6 GHz: 40 dB. 

2.6 GHz to 3.8 GHz: 26 dB. 

3.8 GHz to 8.0 GHz (R3767): 22 dB. 

Crosstaik (25®C ±5®C) - 
R3765: 



Types A and B: 90 dB. 
Type C: 



40 MHz 


to 


2.6 


GHz: 


90 


dB. 


2.6 GHz 


to 


3.8 


GHz: 


85 


dB. 


R3767: 












Types A 


and B: 








40 MHz 


to 


3.8 


GHz: 


90 


dB. 


3.8 GHz 


to 


5.0 


GHz: 


80 


dB. 


5.0 GHz 


to 


8.0 


GHz: 


70 


dB. 


Type C: 












40 MHz 


to 


2.6 


GHz: 


90 


dB. 


2.6 GHz 


to 


3.8 


GHz: 


85 


dB. 


3.8 GHz 


to 


5.0 


GHz: 


70 


dB. 


5.0 GHz 


to 


8.0 


GHz: 


60 


dB. 



Connector - Type N female, 50 Q. 

Noise Level (with respect to -20dB below 
maximum input level of test board) - 

3 kHz bandwidth: -90 dB. 

10 kHz bandwidth: -100 dB. 

Maximum Input Level - 

Types A and B: 0 dBm. 

Type C: 

40 MHz to 3.8 GHz: +15 dBm. 

3.8 GHz to 8 GHz: +12 dBm. 

Input Damage Level - +21 dBm ±30 V DC. 
Maximum Port Bias - ±30 V DC, ±0.5 V 
(Type C only). 

DISPLAY 

Display Type - 7.8-inch TFT color LCD. 
Resolution - 640 x 480 dots. 

Display Mode - Log/linear Cartesian coordi- 
nate, polar coordinate. Smith chart (Imped- 
ance/admittance display). 

Display Format: - 
Single-channel. 

2 channels (overlapped display, 
separated display). 

4 channels (separated display). 

Measurement Condition Display - 
Start/stop, center/span, scale/DIV, reference 
level, marker value, soft key functions, warning 
messages. 

Reference Line Position - Top (100%) to 
bottom (0%) of vertical axis memory. 

Auto Scaie - Sets reference value and scale 
so measured trace can be displayed in opti- 
mum form. 

Brightness; Back-light can be turned ON or OFF. 

MARKER FUNCTION 
Marker Display - Marker reading can be 
converted into a display value in corresponding 
to each measurement format. 

Multi Marker - 10 markers can be set inde- 
pendently for each channel. 

Delta Marker - Each of 10 delta markers can 
be specified as the reference marker and the 
delta value between markers can be measured. 
Marker Couple - Markers of each channel 
can be set in coupled or independent manner. 
Analysis of Specified Region - Marker 
search for section specified with A marker can 
be performed. 

MRK Search - MAX search, MIN search and 
NEXT search. 

Marker Tracking - Search operation for each 
sweep. 



www.tektronix.com/Measuremeiit/comnitest/ 



NETWORK ANALYZERS 209 



Network Analyzers 

R3765AH/BH/CH • R3767AH/BH/CH 






Target Search - Calculates bandwidth, center 
frequency, and Q for -X dB point. Frequency 
for phase 0° and frequency width of ±X®Can 
be searched for. 

MRK -> - MRK “> reference value, MRK -> 
START, MRK -> STOP, MRK -> CENTER. 

INPUT/OUTPUT 

External Display - 15-Pin D-SUB connector 
(VGA). 

GPIB - Conforms to IEEE 488 standard. 
Parallel I/O - TTL level, 8-Bit output (2 
ports), 4-Bit input and output (2 ports). 

Serial I/O - Conforms to RS-232 standard. 
Keyboard Jack - Compatible with IBM PC-AT. 
External Reference Frequency Input - 
Input Frequency Range: 1, 2, 5, and 10 MHz 
±10 ppm. 

Level: >0 dBm. 

Impedance: 50 Q. 



PROGRAMMING FUNaiONS 
BASIC Controller Function - Built-in con- 
troller function can control internal measure- 
ment functions as well as other instruments 
equipped with a GPIB interface. 

Built-in Functions - High-speed analysis of 
measurement data using built-in functions. 
Fioppy Disk Drive (FDD) - MS-DOS compat- 
ible, 3.5-in., 720 K (DD), 1.2 MB (HD), 
or 1.44 MB (HD). 



ENVIRONMENTAL 
Temperature - 

Operating: 

FDD in use: +5°C to +40°C. 

FDD not in use: 0°C to +50®C. 

Storage: -20X to +60°C. 

Relative Humidity (without 
condensation) - 

FDD in use: 85% or less. 

FDD not in use: 80% or less. 

POWER 

Line Voltage - 100 to 120 V AC, 220 to 
240 V AC. Automatic switching between ranges. 

Line Frequency - 48 to 66 Hz. 

Power Consumption - 300 VA or less. 

Safety -UL31 11-1, CSAIOIO.I 

Physical Characteristics 

Dimensions mm in. 



Height 


220 


8J 


Width 


424 


16.7 


Depth 


400 


15.7 


Weieht kg lbs. 




16 


35.3 



Ordering Information 



For price information: Outside the U.S. contact 

R3765AH 

40 MHz to 3.8 GHz Network Analyzer. 

R3765BH 

40 MHz to 3.8 GHz Network Analyzer with 
Internal VSWR Bridge. 

R3765CH 

40 MHz to 3.8 GHz Network Analyzer with 2-Port 
S-Parameter Test Set. 

R3767AH 

40 MHz to 8 GHz Network Analyzer. 

R3767BH 

40 MHz to 8 GHz Network Analyzer with 
Internal VSWR Bridge. 

R3767CH 

40 MHz to 8 GHz Network Analyzer with 2-Port 
S-Parameter Test Set. 

Opt. 70 - Time Domain Analysis. 



your local Tektronix representative, inside the U.S. 

RECOMMENDED ACCESSORIES 
50 Q Termination - Order 26N50. 

75 Q Termination, Type N - Order 26N75. 

50 Q. Calibration Open/Short Connector - 

Order 22N. 

75 Cl Calibration Open/Short Connector, 
Type N - Order 22N75. 

50 Q DC to 18 GHz Calibration Kit (Type N) - 

Order 9617A3. 

50 Cl DC to 18 GHz Calibration Kit (3.5 mm) - 

Order 9617F3. 

Rackmount w/Handles - Order A02712(EIA). 
Rackmount w/o Handles - Order A02722(EIA). 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of Calibration Services. 

Opt. D1 - Cal Data Report. 

Opt. D3 - Test Data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover 
three years. 



the price list in the back of this catalog. 

For your local Tektronix representative see the list in 
the pack of this catalog or outside the U.S. call: 
1-503-627-1916. inside the U.S. call: 1-800-426-2200. 



CC 




Product(s) complies with IEEE Standard 488.1-1987, 
and with Tektronix Standard Codes and Formats. 

ilDVANTEST 

Advantesfs quality system complies with the 

DIN ISO 9002 standard and has been certified by TUV 

Product Service GMBH. 



210 NETWORK ANALYZERS 



www.tektronix.com/Measurement/comnitest/ 






Network Analyzer 

R3754A/3754B 




Features - Benefits 



50 ^Js/point Sweep Time 

-122 dBm Noise Floor 

127 dB Dynamic Range 

10 KHz to 150 MHz Frequency Range 

Self-Diagnostic Function 

Single Key Analysis 
-Filter Analysis 

-Equivalent Circuit Calculations 
-RLA Drive Level Measurement 

1, 2 or 3 Channel Inputs 



Applications 



Design and Test of Crystal and 
Ceramic Components 

Design, Test and Tuning of MRI 
Coils/Antennas 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 

C€ 

ilDVANTEST 

Advantesfs quality ^tem 
complies with the 
DIN ISO 9002 standard and 
has been certified by TUV 
Product Service GMBH. 



The R3754 Series is a high performance network 
analyzer with greatly enhanced functional per- 
formance and a low price. 

Optimization has been made by setting the meas- 
urement frequency range to the limited band- 
width of 10 kHz to 150 MHz. The R3754 Series 
can be used for adjustment and test in the pro- 
duction and inspection processes of crystal, 
ceramic, LC, and sensor parts. Two types of dis- 
play units are selectable according to the appli- 
cation. It is recommended to use the R3754A 
with monochrome display for the pre-process 
and the R3754B with color display for shipment 
inspection and receiving inspection. 

Doubled Maximum Sweep Speed and High 
Throughput 



speed in comparison to our previous model. The 
newly developed measurement algorithm greatly 
improves the total throughput. The improved 
noise floor and increased maximum input level 
create a measurement dynamic range of 127 dB. 

It is possible to measure the high attenuation fil- 
ter at high speed. 

EXCELLENT BASIC PERFORMANCE 

► Noise floor: -122 dBm (7 dB improved in 
comparison to previous Advantest model) 

► Trace noise: typ. -0.0015 dB (2 times improved 
in comparison to previous Advantest model) 

► Stability: typ. -0.02 dB °C (2 times improved 
in comparison to previous Advantest model) 



Advantest in the R3754 has doubled the sweep 



Ordering Information 



For price information: , . 1 .^1 

Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list m the back of this catalog. 

Main Unit Di splay I nput Channe l Jinrijfks 

l^754A 5-inch^monochrome LCD RCH - - — 

R3754B 6-5-inch color RCH _ Additional input c hannel s are optional, 



Opt 01 - Parallel I/O (R3753H compatible). Plu^minus logic change. 
Opt. 02 - Parallel I/O. Pin assignment is changed. 

Opt. 03 - Parallel I/O. Optical Isolation. 

Opt. 10 - 2-Ch Input. RCH, ACH. 

Opt. 11 - 3-Ch Input. RCH, ACH, BCH. 

Opt. 70 - TDR function. Time-axis waveform display. 



Opt. 71 - Drive level measurement function. RLA method. 
Opt. 72 - 3-terminal resonator measurement function. R1704 
and CAL Kit are required. 

Opt. 90 - Japanese manual. Operation, Programming Guide, 
Programming Manual. 

Opt. 91 - English manual. Operation, Programming Guide, 
Programming Manual. 



www.tektronix.com/Measurement/commtest/ 



NETWORK ANALYZERS 211 







Power Meters 



Contents RF Power Measurement 

NRj 213 There are two general types of RF power meters: 

URV5/35 216 ► Terminating power meters absorb the test signal and indicate the resistant power 

NRVD/NRVS 218 ► Directional power meters separately measure the forward and reflected power in 

Power Sensors 222 ^ with practically no loss 



Terminating power meters are often referred to simply as power meters. They typi- 
cally have a resistive input impedance of 50 or 75 Q. Depending on the principle of 
operation, either the heat produced is measured, or the RF power at the termination 
is measured with the aid of a diode rectifier. Conventional power meters with diode 
probes have a limited dynamic range, since departures from linearity of the diode at 
as low as 10 pW cause considerable measurement errors. This range can be extend- 
ed by microprocessor-controlled correction of the rectifier characteristics. 

Directional power meters are inserted into an RF line and measure the forward and 
reflected power separately based upon a directional coupler. Directional power 
meters can thus be used for simultaneously checking the transmitter output power 
and the antenna or load matching. Minimum insertion loss is required for the meas- 
urement of higher power levels. The measuring instrument can thus remain con- 
nected to the transmitter output line for continuous monitoring. Special power sen- 
sors with peak weighting are available for measuring pulsed signals (e.g., in 
GSM/TDMA mobile radio). 

MEASUREMENT ACCURACY 

The most important characteristics of a voltmeter or power meter are high measure- 
ment accuracy and short measurement times. This requires the use of microproces- 
sors and computed correction of factors such as frequency response, temperature 
effect and linearity. This relieves the user of error-prone and time-consuming tasks 
such as recalibration of sensors before measmement, or reading, entering and calcu- 
lating correction factors. 

STORED CALIBRATION DATA FOR EASE OF USE 

The sensors offered for use with the URV, NRT and NRV meters are individually 
calibrated and their calibration data stored in memory. All relevant data required to 
produce accurate results are stored in calibration-data memory and are available to 
the meter when plugged in. Even sensor-specific data such as serial number, sensor 
type and calibration date are known to the meter, in addition to the permissible 
measurement and frequency ranges. Only the frequency of the measurement is 
required; the meter automatically scans the data memory for the relevant calibration 
factors and interpolates if necessary. 



POWER METERS 



www.tektronix.com/Measurement/commtest/ 



Features - Benefits 



Applications 



Power Meters 



New NRT 




Frequency Range: 

200 MHz to 4 GHz 

Power Range: 0.3 mW to 2 kW 

For Power Measurement on 
Transmitters, Amplifiers, Industrial 
RF and Microwave Generators 

For Mobile Use, Service, 
Development, Production and 
Quality Management 
Simultaneous Display of Power and 
Reflection 



Transmitter Test 
VSWR Monitor 
Base Station Commissioning 
Base Station Maintenance 
Remote BTS Monitoring 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 




Product(s) complies with IEEE 
Standard 488.1-1987, RS-232-C, 
and with Tektronix Standard 
Codes and Formats. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



Measurement of Average Power 
Irrespective of Modulation Mode 

Measurement of Peak Power, Crest 
Factor and Average Burst Power 

Up to 3 (4) Measurement Channels 

Compatible with All Main Digital 
Standards, e.g. GSM, DCS 1800, 

PCS 1900, DEa, PHS, NADC, PDC, 
DAB, IS-95 CDMA ... 

Intelligent Sensors: 

Simply Plug in and Go 

IEC625 (IEEE488) Bus and RS-232 
Interface 

Digital Interface Between Sensor 
and Basic Unit 

Direct Connection of Sensor to a PC 



The Next Generation in 
Directional Power Meters 

Directional povy^er meters are used to determine 
transmit power and matching parameters and 
therefore have a long tradition in the installation, 
maintenance and monitoring of transmitters and 
antennas. The new generation of power reflection 
meters not only offers self-contained sensors but 
also an accuracy and a wealth of functions not 
known before, making them suitable, even more 
so than their predecessors, for use in develop- 
ment, testing and quality management. 



Directional power meters are connected between 
source and load and measure the power flow in 
both directions. The power applied to the load 
and the reflection can thus be measured. 

Compared to low-cost instruments, power meters 
like the NRT provide a number of benefits: most 
importantly high measurement accuracy through 
excellent directivity and a measurement method 
that determines the average power like a thermal 
power meter. The instruments thus provide cor- 
rect measurement results even in case of modu- 
lation or in the presence of several carriers. 



www.tektronix.com/Measurement/commtest/ 



POWER METERS 213 






Power Meters 

NEWNRT 



Power Sensors NRT-Z43/-Z44 feature 
low insertion loss, very good matching 
and excellent intermodulation charac- 
teristics: the signal to be measured is 
virtually unaffected, the sensor is fully 
transparent. 

Ease of Operation 

With its large display and a manageable 
number of clearly laid out keys, opera- 
tion of the NRT basic unit is extremely 
easy. Switchover between the main 
functions is made at a keystroke. 
Additional settings are made in three 
clearly arranged menus, each of which 
can be accessed at a keystroke. 

A large variety of functions is available 
for daily routine measurements: 

► Choice between average power, aver- 
age burst power, peak envelope 
power (PEP) and peak-to-average 
power ratio (crest factor) 

► Switchover between forward power 
and absorbed power 

► Measurement of power differences 
in dB or % 

► Choice between return loss, SWR or 
reflection coefficient in reflection 
measurements 

► Acoustic SWR monitoring 

► Indication of maximum and mini- 
mum values 

► Quasi-analog bar graph display 

► Choice between measurement at the 
source or at the load 



Versatility Through Options 

The NRT basic unit comes with an lEC- 
bus (IEEE488) and RS-232 interface, 
both to SCPI standard. Three options 
allow the NRT to be adapted to differ- 
ent applications: 

► An additional test input allows the 
sensors of predecessor model NAP to 
be connected, thus covering the fre- 
quency range from 200 kHz with 
power up to 1 kW and above (NRT-Bl) 

► Two additional test inputs for sen- 
sors of type NRT-Z allow simultane- 
ous monitoring of up to three test- 
points (NRT-B2) 

► Battery and built-in charger allow 
mobile use (NRT-B3) 




The Best in Sensors 

DIREaiONAL POWER SENSORS 
NRT-Z43/-Z44 

The new Power Sensors NRT-Z43 and 
NRTZ44 can be used as self-contained 
measuring instruments with digital 
interface even without the basic unit. In 
addition to a directional coupler and 
analog section they comprise a proces- 
sor kernel for control of the hardware 
and remote interface and for processing 
the measured data (temperature com- 
pensation, linearization, zeroing and fre- 
quency-response correction). This com- 
pact concept allows a wealth of meas- 
urement functions without the restric- 
tions of conventional analog concepts. 



214 



POWER M ETERS 



www.tektronix.com/Measurement/commtest/ 



Power Meters 

NEW NRT 



AVERAGE POWER (RMS VALUE) 

This measurement function returns for 
any type of test signal - whether modu- 
lated, unmodulated or several carriers 
- the average value of the power, i.e. a 
result as provided by a thermal power 
meter. It features a measurement range 
of 35 to 40 dB as well as high measure- 
ment accuracy. 



PEAK ENVELOPE POWER (PEP) AND 
CREST FAaOR 

These two parameters provide informa- 
tion on the peak power of a modulated 
envelope and thus describe the overdrive 
characteristics of transmitter output 
stages. The result of the crest factor meas- 
urement is referred to the average power 
and read out in dB. The measurements 
are carried out with a video bandwidth 
adjustable in several steps and allow 
determination of peak power down to a 
duration of 200 ns, i.e. the peak power of 
spread-spectrum signals with RF band- 
'widths of up to about 2 MHz (IS-95 
CDMA, DAB) can also be measured. 



AVERAGE BURST POWER 

This function can be used for measuring 
modulated and unmodulated bursts. The 
measurement is based on the average 
power and the duty cycle, which may be 
defined by the user or determined auto- 
matically by the power sensor. 

COMPLEMENTARY CUMULATIVE DIS- 
TRIBUTION FUNCTION (CCDF) 

This function measures the probability 
of the peak envelope power exceeding a 
preset threshold and thus allows deter- 
mination of the amplitude distribution 
of nondetermined modulation signals. 



your local Tektronix representative, inside the U.S. see 

NAP-Z9 - 1.1 W, 100 to 1000 MHz. Order 
0392.5513.55. 

NAP-Z10 - 20 W, 35 to 1000 MHz. Order 

0858.0000. 02. 

NAP-Z10 - 20 W, 890 to 960 MHz. Order 

0858.0000. 04. 

NAP-Z1I - 200 W, 35 to 1000 MHz. Order 

0852.6707.02. 

NAP-ZII - 200 W, 890 to 960 MHz. Order 
0852.6707.04. 

NAP-Z42 - 110 W, 0.9 to 2 GHz. Order 

0852.7403.02. 

NAP-CAL - Calibration at delivery NAP-Z (CAL-1). 
Order 0240.8727.06. 



Ordering Information 



For price information: Outside the U.S. contact 

BASIC UNIT 

NRT - Power Reflection Meter. Order 1080.9506.02. 

DIRECTIONAL POWER SENSORS NRT* 

NRT-Z43 - 30 (75) W, 0.4 to 4 GHz. Order 

1081.2905.02. 

NRT-Z44 - 120 (300) W, 0.2 to 4 GHz. Order 

1081.1309.02. 

NRT-CAL - Calibration certification data NRT- 
Z43/-Z44 (CAL-1). Order 0240.8727.06. 

DIRECTIONAL POWER SENSORS NAP 
NAP-Z3 - 35 W, 25 to 1000 MHz. Order 

0392.6610.55. 

NAP-Z4 - no W, 25 to 1000 MHz. Order 

0392.6910.55. 

NAP-Z5 - 350 W, 25 to 1000 MHz. Order 

0392.7116.55. 

NAP-Z6 - 1100 W. 25 to 1000 MHz. Order 

0392.7316.56. 

NAP-Z7 - 200 W, 0.4 to 80 MHz. Order 

0350.8214.02. 

NAP-Z8 - 2000 W, 0.2 to 80 MHz. Order 

0350.4619.02. 



www.tektronix.com/Measurement/comintest/ 



OPTIONS 

NRT-B1 - Interface for NAP-Z Power Sensors. Order 

1081.0902.02. 

NRT-CAL - Calibration certification data NRT-Bl 
(CAL-1). Order 0240.8727.06. 

NRT-B2 - Two rear inputs for NRT-Z Power Sensors. 
Order 1081.0702.02. 

NRT-B3 - Battery supply with built-in charger and 
NiMH battery. Order 1081.0502.02. 



the price list in the back of this catalog. 

RECOMMENDED ACCESSORIES 

NRT-Z1 - NiMH Battery. Order 1081.1209.02. 

NRT-Z2 - 10 m Extension Cable 

for NRT-Z Power Sensors. Order 1081.2505.10. 

NRT-Z2 - 30 m Extension Cable 

for NRT-Z Power Sensors. Order 1081.2505.30. 

NAP-Z2 - 25 m Extension Cable 

for NAP-Z Power Sensors. Order 0392.5813.02. 

NRT-Z3 - RS-232 Interface Adapter 

for NRT-Z Power Sensors including AC Power Supply. 

Order 1081.2705.02. 

ZZT-222 - Carrying Bag with Straps and Pocket for 
Accessories. Order 1001.0500.00. 

ZZA-97 - 19" Rack Adapter. Order 0827.4527.00. 
*lncluding demo software. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916. inside the U.S. cail: 1-800-426-2200. 



Product(s) complies with IEEE Standard 488.1-1987, 
RS-232-C, and with Tektronix Standard Codes and Formats. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



POWER METERS 215 






Features - Benefits Applications 



URV 5 

DC, 9 kHz to 2 GHz Frequency 
Range (40 GHz with NRV-Z 
Sensors) 

200 jjV to 1000 V Measurement 
Range 

Two Test Inputs 

Microprocessor Error Correction for 
Unexcelled Accuracy 

Relative Measurements 



Service 

Production 

Precision Measurements in RF and 
Microwave Labs 



Individual, Frequency-dependent 
Calibration Factors Taken into 
Account 



URV 35 

DC to 26.5 GHz Frequency Range 
Compact, Rugged Design 
Voltmeter & Power Meter in One Unit 
Combined Analog & Digital Display 
Battery or AC Supply Operation 
Wide Choice of Probes and Sensors 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 




URV5 complies with 
IEEE standard 488.1-1987, 
and with Tektronix Standard 
Codes and Formats. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



URV 5 RF Millivoltmeter 

The URV 5 RF Millivoltmeter is a broadband 
voltage, level and power meter with high accura- 
cy and sensitivity. It is suitable for both manual 
operation and use in systems. A great variety of 
probes, sensors and accessories allows the URV 
5 to be used for all kinds of measurements. 

URV 35 Level Meter 

The URV 35 Level Meter is a precise voltage and 
power meter for a large variety of applications. It 
can be used in service and production, as well as 
for precision measurement in the RF and 
microwave lab. 

The large variety of probes and sensors available 
opens up a wide level and frequency range. 
Excellent RF shielding provides precise meas- 
urements, even in the near field of antennas. 



An intelligent operating concept in conjunction 
with an auto-range facility reduces the user’s 
work to read the results in standard units, either 
as absolute or relative values. The appropriate 
scale is shovvm on the LCD display for conven- 
ient reading of the results. 



Characteristics 



URV 5 

Probes and Sensors - Compatible with all URV 5 
probes and NRV sensors except NRV-Z51, NRV-Z52, NRV- 
Z53, NRV-Z54 and NRV-Z31. 

Test Channels - 2 (A and B). 

Dynamic range: >94 dB. 

Absolute measurement: A, B. 

Relative measurement: /VREFa, B/REFb, A/B, B/A 
Absolute readout: V, W, dBm, dBV. 



216 POWER METERS 



www.tektronix.com/Measurement/commtest/ 










Power Meters 

URV 5 • URV 35 



Relative readout: AV, AW, A% AdB, X/REF. 
Resolution: 0.01% or dB. 

Error limits (18 to 28®C): ±0.15% of reading per 
channel. 

Filter: Reduces display noise in six steps (FO to F5). 
Zero adjustment: Via keyboard or remote control. 
Measurement rate (manual): Approximately 1 
measurement/second with filter FO, up to 30 
measurements/second with filter F5. 
Measurement time (lEC/IEEE bus): 
Approximately 0.05 second with filter F5, up to 
20 seconds with filter FO. 

PEP Measurement - Pulse width: 
Approximately 200 ps to CW. 

Minimum pulse repetition frequency: 

Fitter FO FI F2 F3 F4 F5 

WHz 0.05 0.25 1 5 25 100 

Optional DC Output (URV 5 with Opt. 01) - 

Output voltage range (EMF): -1.999 to 
+1.999 V into Zout = 1 ka. 

Resolution: 1 mV (10 digits). 

Error: ±2 mV. 

Remote Control - Interface: IEC625-1 (IEEE 
488) for control of all device functions. 

Interface functions: SHI, AHl, T5, L4, SRI, RLl, 
DCl, DTI, PPl. 

Physical Characteristics 

Dimensions ^mm in. 



Height 110 4.3 



Width 


241 


9.5 


Depth 


340 


13.4 


Weight 


kS 


lbs. 


Net 


4.4 


9.7 



URV 35 

Probes and Sensors - Compatible with all 
URV 5-Z probes and NRV-Z sensors. 
Frequency Range - DC to 26.5 GHz. 

Display - Backlit LCD for display of measured 
value, units and meter scale; additional mov- 
ing-coil meter with short response time. 
Absolute readout: dBm, dBpV, V or W. 

Relative readout: dB referred to stored refer- 
ence value. 



Resolution of digital display - 
4 1/2 digits: 19,999 steps, 0.001 dB. 

3 1/2 digits: 1,999 steps, 0.01 dB. 

Analog display: Steps of 1/2.5/5 with readout 
in V, W, or dB; steps of 5 dB with readout 
in dBm and windows of 10 dB, manually or 
automatically selected; free scaling by entry of 
left-hand and right-hand scale limits. 

Display filtering: Level-dependent digital aver- 
aging filter. 

4 1/2 -digit resolution: Averaging over 16 to 
256 readings. 

3 1/2 -digit resolution: Averaging over 1 to 32 
readings. 

Error Limits (18 to 28*’C) - Digital display: 
±0.02 dB ±1 digit. 

Moving-coil meter: 1.5% of full scale. 

Zero Adjustment - Via interface or manually, 
«4s. 

HOLD Function - Displayed measurement 
result retained upon keystroke. 

Measurement Rate - Five readouts per sec- 
ond in manual mode. 

Frequency-response Correction - Specific 
calibration data of probe taken into account; 
frequency entry via keypad, interface or equiv- 
alent DC voltage at rear-panel input. 
Attenuation Correction - Attenuation or 
gain connected to input taken into account- 
input of attenuation value via serial interface or 
keypad, range ±199.99 dB. 

Reference Value Entry - 

Measured value on keystroke or value entered 

via interface or keypad. 

Reference Impedance - 
50 Q/75 Q, automatic/selectable. 
Input/Output - DC frequency input: 
Connector: BNC female. Input impedance: 

9 MQ. Input voltage range: ±12 V, freely selec- 
table, linear, scaling. Maximum input voltage: 

50 V. DC 

Voltage Output: Connector: BNC female. Source 
impedance: 1 kQ. Output voltage (EMF): 
Proportional to pointer deflection. Left-hand 
scale limit: Corresponding to 0 V. Right-hand 



scale limit: Corresponding to 0 V. Settling time: 
250 ms. Error: <5 mV. Ripple: 5 mV p-p typical. 
Remote Control - All device functions con- 
trolled via serial Interface (V.24, RS-232C). 

POWER REQUIREMENTS (URV 5 AND 
URV 35) 

Battery Operation (URV 35 Model 02) - 

Battery type: 5 LR20 (1.5 V). Operating time: 
Approximately 125 hours. Charge time (with 
UZ-35 charger): Approximately 24 hours. 

AC Operation 

(URV 5 and URV 35 Model 03) - 

Line voltage: 100/120/220/240 VAC ±10o/o. 

Line frequency: 47 to 63 Hz, 400 Hz. 

Power consumption: 30 VA. 

ENVIRONMENTAL CHARAaERISTICS 
(URV 5 AND URV 35) 

Temperature Range - Operating: 0 to +50®C 
(Class I to lEC 359, no condensation). 

Storage: -40 to +70°C. 

Humidity - 80% maximum (without conden- 
sation). 

Mechanical Strength - To I EC 359, Class I. 
RFI Suppression - VDE 0871, DBP approval 
number to regulations 527/1979. 

EMC - To lEC 801.3, severity level 3; MIL-STD- 
461 -B RS 03 and CS 02. 

Physical Characteristics 



Dimensions mm in. 



Height 


103 


4.1 


Width 


219 


6.6 


Depth 


240 


9.4 


Weight 


h* 


lbs. 


Model 02 


With batteries 


3.1 


6.8 


Without batteries 


2.3 


5.1 


Model 03 


2.4 


5.3 



Ordering Information 



For price information: Outside the U.S. contact 

URV 5 

RF Millivoltmeter. 

Includes: Power Cord, Manual. 

Opt. 01 - DC Output. 

URV 35 MODEL 02 

RF Millivoltmeter (Battery Operated). 

URV 35 MODEL 03 

RF Millivoltmeter (AC Supply). 

Includes: Power Cord, Manual. 



’ local Tektronix representative, inside the U.S. see 

RECOMMENDED ACCESSORIES 

Also see page 495. 

Battery Charger - Order UZ-35. 

Service Kit - Order URV 35-Zl. 

Transit Case - Order UZ-22. 

Carrying Strap - Order ZZT-96. 

Rack Adapter - Order ZZA-97. 

Plastic Hood - 

Probes and Sensors - See page 222. 

*1 Contact your local Tektronix representative. 



the price list in the back of this catalog. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 




Product(s) complies with IEEE Standard 488.1-1987, 
RS-232-C, and with Tektronix Standard Codes and Formats. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



www.tektronix.com/Measurement/commtest/ 



POWER METERS 217 




Applications 





Power Meters 

NRVD 




Features - Benefits 



DC to 40 GHz Frequenq^ Range Laboratory Test 

Two Independent Channels for Production Test 

Simultaneous Measurement Research and Development 

Power, Level and Voltage 
Measurements 

Intelligent Measuring Heads - Just 
Plug Them in and Measure 

Autoranging 

Entry of Reference Values for Level 
and Attenuation 



Storage of 20 Complete Instrument 
Setups 

Built-in Test Generator for Checking 
Sensors 



Remote Control of All Functions via 
lEC/IEEE Bus 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 




Product(s) complies with 
IEEE Standard 488.2-1987, 
and with Tektronix Standard 
Codes and Formats. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



NRVD Dual-channel Power Meter 

The NRVD Dual-channel Power Meter functions 
like two independent measuring instruments 
housed in one cabinet to perform measurements 
simultaneously and exchange data with one 
another. The two channels can be separately set 
so that two completely different measurements 
can be carried out at the same time. The two 
measured values can also be related to each 
other for direct indication of reflection coeffi- 
cient, SWR and return loss, for instance, when 
an SWR bridge is connected to the meter. 

READOUT OF RESULTS 

Measurement results are displayed with selectable 
resolution on a large 5-digit LCD display with 
adjustable backlighting. The values measured in 
the two channels, or one measured value plus an 
additional item of information (e.g., the correction 
frequency) are displayed simultaneously. All stan- 
dard units of measurement or relative modes can 
be selected. Relative measurements are either 
referred to a stored reference value or to the value 



measured in the second channel. A high-resolu- 
tion bar graph indicator with selectable scaling or 
autoscaling permits quasi-analog display of meas- 
ured values with any unit or resolution. 

POWER SENSORS 

The range of probes and sensors includes thermo- 
couple power sensors, as well as highly sensitive 
diode power sensors, probes, and insertion units. 
This allows the NRVD to cover a frequency range 
from DC to 26.5 GHz and a power span from 400 
pW up to the kW range. 

TEST GENERATOR 

A test generator is included to check measuring 
heads and sensors for proper functioning. It gen- 
erates a low-distortion, highly accurate 50 MHz 
signal of 1 mW power (0 dBm). 

INPUT/OUTPUT WITH OPT. 01 

Option 01 provides a number of inputs and out- 
puts to extend the range of the NRVD. 



218 POWER METERS 



www.tektronix.com/Measurement/commtest/ 








Power Meters 

NRVD 



Characteristics 



Measurement Functions - Unmodulated 
and modulated power (average power, AM, 
pulse power), reflection and DC voltage 
(depending upon measuring head). 

Frequency Range - DC to 26.5 GHz (depend- 
ing upon measuring head). 

Level Range - 400 pW to 0.5 W (depending 
upon measuring head). 

Measuring Heads - All NRV-Z and URV 5-Z 
voltage and power measuring heads. 

Display - LCD with adjustable backlighting for 
figures, units, user prompting and analog dis- 
play. 

Resolution of Digital Display - 5 digits 
maximum, resolution adjustable in 3 modes. 
HIGH: 12,000 steps or 0.001 dB. 

MEDIUM: 1,200 steps or 0.01 dB. 

LOW: 120 steps or 0.1 dB. 

Display Noise - See measuring head specifi- 
cations. 

Measurement Rate - See Table 2. 

Error Limits of Power Readout in W 
(Without Error of Measuring Head) - 

18 to 28°C: 0.3% + 1 digit. 

10 to 40®C: 0.80y^ + 1 digit. 

0 to 50®C: 1.3o^ + 1 digit. 

Zero Adjustment - Manual or via I EC/IEEE 
bus, duration ~ 4 s. 



Frequency Response Correction - Stored 
frequency response of measuring head taken 
into account by numerical entry of test fre- 
quency (manually or via lEC/IEEE bus) or by 
applying a frequency-proportional DC voltage. 
Attenuation Compensation - Attenuation or 
gain connected to input taken into account- 
entry of attenuation value (±200 dB) via key- 
board or IEC/IEEE bus. 

Reference Value - One reference value per 
channel for relative measurements; numeric 
entry via keyboard or lEC/IEEE bus, or use 
stored measured value or current value of sec- 
ond channel. 

Remote Control - Control of all instrument 
functions via lEC 625/IEEE 488 interface. 
Interface functions: SHI, AHl, T6, L4, SRI, RLl, 
DCl, DTI, PRO, PPL 
Test Generator - 
Output power: 1.00 mW. 

Frequency: 50 MHz. 

Power measurement error: <0.7%. 

SWR: <1.03. 

RF connector: N female. 

DC Control Input for Frequency Response 
Correction - 

Connector: BNC female. 

Input level: ±12 V, linear with selectable scale. 
Input impedance: 9 MQ. 

Maximum input voltage: 50 V. 



I/O with Opt. 01 - 

Output: Two analog outputs for simultaneous 
output of measurement results of both chan- 
nels. 

Output impedance: 1 kQ. 

Voltage range: 0 to 3 V. 

Resolution: 1 mV. 

Error: <5 mV. 

Input: DC input for analog frequency response 
correction. 

Voltage range: ±12 V. 

Input impedance: 1 M^2. 

Trigger input: TTL, active low. 

Ready output: TTL, active high. 

POWER REQUIREMENTS 
Line Voltage - 110/120 V ±100yb; 

220 V ±10%, 230V-6/+15%. 

Line Frequency - 47 to 63 Hz. 

Power Consumption - 25 VA. 

ENVIRONMENTAL CHARAaERISTICS 

EMC - lEC 801-3, severity level 3; 
MIL-STD-461-B; RS 03 and CS 02. 

Physical Characteristics 

Dimensions mm in. 



Height 


147 


5.8 


Width 


219 


8.6 


Depth 


350 


13.8 


WeizM 


H 


ibs. 


Net 


4.5 


9.9 



Ordering Information 



For price information: Outside the U.S. contact 

NRVD 

Dual-channel Power Meter. 

Includes: Power Cable, Manual. 

Opt. 01/NRVD-B2 - I/O Option. 

MEASUREMENT SERVICE OPTIONS 
Opt. R3 - Repair warranty extended to cover 
three years. 



your local Tektronix representative, inside the U.S. 

RECOMMENDED ACCESSORIES 

Also see page 495. 

See Probes and Sensors, Page 222. 

Rack Adapter - Order ZZA-98. 

Accessory Bag - Order ZZT-92. 

Carrying Straps - Order ZZT-96. 

Transit Case - Order ZZK-983. 

Service KH - Order NRVD-Sl. 



the price list in the back of this catalog. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916. Inside the U.S. call: 1-800-426-2200. 




Product(s) complies with IEEE Standard 488.2-1987, 
and with Tektronix Standard Codes and Formats. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



see 



www.tektronix.com/Measurement/commtest/ 



POWER METERS 219 









Features - Benefits Applications 



DC to 26.5 GHz Frequenq^ Range Laboratory 

Power, Level and Voltage Production 

Measurements 

Intelligent Measuring Heads - Just 
Plug Them in and Measure 

DC Frequency Input for Tracking 
Frequency-response Correction 

Analog Output 
Menu-guided Operation with 
Softkeys 

Storage of 20 Complete Instrument 
Setups 

13 Digital Filters for Noise 
Suppression, Automatic or Manual 
Filter Selection 



Remote Control of All Functions via 
lEC/IEEE Bus 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 




Product(s) complies with IEEE 
Standard 488.1-1987. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



NRVS Power Meter 

The NRVS Power Meter is the ideal instrument 
for any kind of power measurement in laboratory 
and system applications. Intelligent probes with 
calibration data memory and thermocouple sen- 
sors make user adjustments unnecessary. The 
NRVS provides high-precision measurements 
free of operator errors. 

READOUT OF RESULTS 

Measurement results, units and various items of 
information are displayed on a large 4 1 /2-digit 
LCD display in three steps of resolution. All 
standard units of measurement or relative modes 
can be selected. A high resolution bargraph indi- 
cator with selectable scaling or auto-scaling per- 
mits quasi-analog display of measured values 
with any unit of resolution. 

If pulse-modulated signals are measured, the 
NRVS calculates the pulse peak power from the 
measured average value and the entered pulse 
duty factor; the result is directly displayed. 



MEASUREMENT RATE 

The attainable measurement rate depends upon 
the type of measuring head used as well as the 
setting of the averaging filter, which must be 
matched to the measurement conditions. Taking 
into account the connected measuring head, the 
NRVS automatically selects the appropriate 
measurement rate by determining the optimum 
averaging time required for a steady readout as a 
function of level and selected resolution. This 
automatic selection may be disabled and an 
averaging time of between 4 ms and 25 s set 
manually to measure more quickly than in auto- 
matic operation or to further reduce the noise. 

POWER SENSORS 

The range of probes and sensors includes ther- 
mocouple power sensors, as well as highly sensi- 
tive diode power sensors, probes and insertion 
units. This allows the NRVS to cover a frequency 
range from DC to 26.5 GHz and a power span 
from 400 pW up to the kW range. 



220 POWER METERS 



www.tektronix.com/Measurement/commtest/ 






Power Meters 

NRVS 



Characteristics 



Measurement Functions - Average power, 
pulse power, DC voltage (depending upon 
measuring head). 

Frequency Range - DC to 26.5 GHz (depend- 
ing upon measuring head). 

Level Range - 400 pW to 0.5 W (depending 
upon measuring head). 

Measuring Heads - Ail NRV-Z and URV 5-Z 
voltage and power measuring heads. 

Display - LCD for figures, units, user prompt- 
ing and analog display. 

Readout - 

Absolute: W, dBm, V, dBpV. 

Relative: dB, %W or %V referred to a stored 
reference value, numeric readout with or with- 
out display of correction frequency. 

Analog Display - 
Automatic or with selectable scale. 

Resolution of Digital Display - 4 1/2; digits 
maximum, resolution adjustable in 3 modes. 
HIGH: 12,000 steps or 0.001 dB. 

MEDIUM: 1,200 steps or 0.01 dB. 

LOW: 120 steps or 0.1 dB. 

Display Noise - See measuring head specifi- 
cations. 

Measurement Rate - See Table 2. 



Error Limits of Power Readout in W 
(without error of measuring head) - 

18 to 2SX: O.40/0 + 1 digit. 

10 to 40°C: O.90/0 + 1 digit. 

0 to 50°C: 1.40/0 + 1 digit. 

Zero Adjustment - Manual or via lEC/IEEE 
bus, duration « 4 s. 

Frequency Response Correction - Stored 
frequency response of measuring head taken 
into account by numerical entry of test fre- 
quency (manually or via lEC/IEEE bus) or by 
applying a frequency-proportional DC voltage. 
Attenuation Compensation - Attenuation or 
gain connected to input taken into account- 
entry of attenuation value (±200 dB) via key- 
board or lEC/IEEE bus. 

Reference Value - Numeric entry via key- 
board or lEC/IEEE bus, or use stored measured 
value. 

Reference Impedance - For conversion 
between voltage and power, automatic readout 
of reference impedance from data stored in 
the measuring head or numeric entry via key- 
board or lEC/IEEE bus (for RF probe). 

Remote Control - Control of all instrument 
functions via I EC 625/IEEE 488 interface. 
Interface functions: SHI, AHl, T6, L4, SRI, RLl, 
DCl, DTI, PRO. 

DC Control Input for Frequency Response 
Correction - 

Connector: BNC female. 

Input level: ±12 V, linear with selectable scale. 
Input impedance: 9 MQ. 

Maximum Input voltage: 50 V. 



DC Output - 

Connector: BNC female. 

Source impedance: 1 kO.. 

Output voltage (EMF): Proportional to deflec- 
tion of analog display. 

Full scale value: Left 0 V, right +3 V. 

Additional settling time: 250 ms. 

POWER REQUIREMENTS 

Line Voltage - 115 V +15/-22o/o; 230 V 

+15/-220^. 

Line Frequency - 47 to 63 (440) Hz. 

Power Consumption - 13 VA. 

ENVIRONMENTAL CHARAaERISTICS 
Temperature Range - 

Operating: 0 to +50®C, for use In Class I to 
lEC 359. 

Storage: -40 to +70®C. 

Humidity - To 80% (without dewing). 
Mechanical Stability - lEC 359, Class I. 

RFI Suppression - DBP approval number to 
regulations 527/1979, VDE 0871. 

EMC - lEC 801-3, severity level 3; 
MIL-STD-461-B; RS 03 and CS 02. 

Physical Characteristics 

Dimensions mm in. 



Height 


103 


4.1 


Width 


219 


8.6 


Depth 


350 


13.8 


Weight 




lbs. 


Net 


. 

3.2 


7.1 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 



NRVS 

Power Meter. 

Includes: Power Cord, Manual. 

MEASUREMENT SERVICE OPTIONS 

Opt. R3 - Repair warranty extended to cover three 

years. 



RECOMMENDED ACCESSORIES 

Also see page 495. 

See Probes, Sensors and Insertion Units, page 222. 

Rack Adapter - Order ZZA-97. 

Accessory Bag - Order ZZT-92. 

Carrying Straps - Order ZZT-96. 

Transit Case - Order ZZK-973. 

Service Kit - Order NRVS-1. 




Product(s) complies with IEEE Standard 488.1-1987. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



www.tektronix.com/Measurement/commtest/ 



POWER METERS 221 








Features - Benefits 



Thermocouple Sensors 
Diode Sensors 

Diode Sensors with an Integral 
20-dB Attenuator 

Peak Power Sensors 
RF Probes 
RF Insertion Units 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



A Full Range of Probes, Insertion 
Units and Power Sensors 

These probes, insertion units and power sensors 
extend the measurement range and offer added 
measurement capability. 

THE RIGHT SENSOR FOR EVERY APPLICATION 

Power sensors absorb the power applied and 
provide an equivalent DC voltage at their output. 
To cover the complete power range from less 
than 1 nW to more than 100 mW, two different 
types of power sensors are required: thermocou- 
ple sensors based on the Seebeck effect and 
semiconductor detectors using zero-bias 
Schottky diodes. Both types of transducers are 
available for the entire frequency spectrum. 

THERMOCOUPLE SENSORS 

Thermocouple sensors open up a wide power 
range from 1 pW to 100 mW. Regardless of the 
waveform, they always indicate the RMS power 
over the full range, giving precise results, even 
for modulated or complex signals. 



DIODE SENSORS 

Diode sensors feature a higher sensitivity. They 
are able to measure power to as low as 100 pW. 
Since they measure true RMS power down to 10 
pW, they can even be used for signals with har- 
monic contents, noisy or modulated signals. 

DIODE SENSORS WITH AN INTEGRAL 20-DB 
ATTENUATOR 

Diode sensors with an integral 20-dB attenuator 
fill the gap between pure diode sensors and 
thermocouples. They provide true RMS measure- 
ments in a range up to 1 mW and satisfy the most 
exacting requirements on measurement speed, 
even for levels between 10 and 100 pW, where 
the use of thermocouple sensors is limited. 

PEAK POWER SENSORS 

Peak power sensors contain rectifiers for measur- 
ing the peak modulation. They enable direct 
measurement of the TV sync pulse peak power, 
the power of TDMA signals, as well as of other 
pulsed signals with a pulse width from 2 ps. In 
the frequency range from 1 pW to 20 mW, these 
sensors are a value-for-money alternative to spe- 
cial peak power meters. 



222 



POWE R meters 



www.tektronix.com/Measurement/commte$t/ 





Power Meters 

POWER SENSORS • PROBES • RF INSERTION UNITS 




Voltage Probes for the URV/NRV family. 



RF PROBES 

RF probes are indispensable for meas- 
urements on non-coaxial circuits and 
components. Small input capacitance 
and low loss enable low-load measure- 
ments directly in the circuit. Dividers 
increase the voltage measurement range 
and minimize the loading of the device 
under test. 

RF INSERTION UNITS 

RF insertion units are used for voltage 
measurements in coaxial circuits. They 
incorporate a diode inserted in the 
inner conductor or connected via a pis- 
ton attenuator and permit broadband 
measurements to be made up to 2 GHz 
with low reflection coefficient. Given 
matched conditions, these insertion 
units can also be used for practically 
no-loss measurements of RF power. 



Measuring Heads 

Probes 



URV 5-Zl 


DC Probe 0 to 400 V, 
9Mn,3pF 




URV 5-Z702, 4 ft. cable 


RF Probe 


RF Probe 




200 pVto 10 V, 


low capacitance 


URV 5-Z703, 16 ft. cable 


20 kHz to 1 GHz 


and resistive load 


URV-Z6 with 20 dB 


2 mV to 100 V, 


The 20 dB and 40 dB plug-on 


plug-on divider*’ 


1 to 500 MHz 


dividers increase the voltage 
measuring range of the RF probe 


URV-Z6 with 40 dB 


20 mV to 1000 V, 




plug-on divider*’ 


500 kHz to 500 MHz 




URV-Z50 with 


200 pVto 10 V, 


With integrated termination 


50 Q Adapter 


20 kHz to 1 GHz 


for power or level 



measurements on test items, 
with a source impedance 
of 50 D in the frequency range 
up to 1 GHz (BNC female/male) 



URV-Z3 with 75 Q Adapter 


200 pV to 10 V, 
20 kHz to 500 MHz 




*’ Included in accessory URV-Z6. 




RF Insertion Units 

(unless otherwise specified, all insertion units with N male/female; all power sensors with N male connectors) 


URV 5-Z25, 4 ft. cable 
URV 5-Z26, 16 ft. cable 


200 pV to 10 V Insertion 
Unit 50 Q 9 kHz to 2 GHz 




URV5-Z44,4ft.cable 
URV 5-Z45, 16 ft. cable 


2 mV to 100 V Insertion 
Unit 50 a 100 kHz to 2 GHz 




URV5-Z46,4ft.cable 
URV5-Z47, 16 ft. cable 


2 mV to 100 V Insertion 
Unit 75 D 100 kHz to 2 GHz 




NAS-Zl 


120 W Insertion Unit 1 to 30 MHz 




NAS-Z2 


1200 W Insertion Unit 1 to 30 MHz 




NAS-Z3 


120 W Insertion Unit Z5 to 200 MHz 




NAS-Z5 


120 W Insertion Unit 70 to 1000 MHz 




NAS-Z6 


120 W Insertion Unit 890 to 960 MHz 




NAS-Z7 


30 W Insertion Unit 
890 to 960 MHz, 
1710 to 1880 MHz 


For GSM, DCS 1800 



www.tektronix.com/Measurement/commtest/ 



POWER METERS 



223 



Power Meters 



POWER SENSORS • 


PROBES • RF INSERTION UNITS 




Power Sensors 


NRV-Zl 02, 4 ft. cable 
NRV-Zl 03, 16 ft, cable 


1 nWto 20 mW, 

Diode Power Sensor 50 Q 10 MHz to 18 GHz 




NRV-Z2 02,4ft.cable 
NRV-Z2 03, 16 ft. cable 


Diode Power Sensor 50 Q 
10 MHz to 18 GHz, 100 nW to 500 mW 




NRV-Z3 02,4ft.cable 
NRV-Z3 03, 16 ft. cable 


Diode Power Sensor 75 Q 
1 MHz to 2.5 CHz, 400 pW to 13 mW 




NRV-Z4 02,4fLcable 
NRV-Z4 03, 16 ft. cable 


Diode Power Sensor 50 fZ 
100 kHz to 6 GHz, 500 pW to 20 mW 


Power measurements of highest sensitivity in the 
frequency range 100 kHzto 6 GHz, very large dynamic range 


NRV-Z5 02, 4 ft. cable 
NRV-Z5 03, 16 ft. cable 


Diode Power Sensor 50 iZ 
100 kHz to 6 GHz, 50 nW to 500 mW 




NRV-Z6 


Diode Power Sensor 50 fZ 50 MHz to 26.5 GHz» 1 nW to 20 mW 




NRV-Z7 


Diode Power Sensor 50 fZ 10 MHz to 13 GHz, 1 nW to 20 mW 




NRV-Z8 


Diode Power Sensor 50 Q 10 MHz to 13 GHz, 100 nW to 500 mW 




NRV-Z15 


Diode Power Sensor 50 Q, 50 MHz to 40 GHz, 1 pW to 20 mW 




NRV-Z31 


Peak Power Sensor 50 £2 
30 MHz to 6 GHz, 1 |iW to 20 mW 


Peak power measurements, pulse width >2 (200) ps, 
pulse repetition rate >10 (100) Hz, 3 models 


NRV-Z51 


Thermocouple Sensor 50 £2 
DCtolSGHz,! uWtolOOmW 


High-precision power 

measurements also with non-sinusoidal signals 


NRV-Z52 


Thermocouple Sensor 50 £2 
DC to 26.5 GHz, I uW to 100 mW 


Like NRV-Z51, but with PC 3.5 connector 
for measurements up to 26.5 GHz 


NRV-Z53 


Thermocouple Sensor 50 £2 
DC to 18 GHz, lOOilWtoIOW 


High-power measurements 
up to 10 W also with non-sinusoidal signals 


NRV-Z54 


Thermocouple Sensor 50 £2 
DC to 18 CHz 300 mW to 30 W 


High-power measurements 
up to 30 W also with non-sinusoidal signals 


NRV-Z55 


Thermal Power Sensor 
50a0-4GHzlMWtOl00MW 


High Precision measurement 
of non-sinusoidal signals to 40 GHz 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



PROBES 

DC Probe - Order URV 5-Zl. 

RF Probe - Order URV 5-Z7. 

RF Probe with 20 dB and 40 dB Plug-on 
Divider - Order URV-Z6. 

RF Probe with 50 Q Adapter - Order URV-Z50. 
RF Probe with 75 Q Adapter - Order URV-Z3. 

RF INSERTION UNITS 
10 V Insertion Unit 50 Q - Order URV 5-Z2. 
100 V Insertion Unit 50 ^2 - Order URV 5-Z44. 
100 V Insertion Unit 75 Q - Order URV 5-Z47. 
120 W Insertion Unit, 1 to 30 MHz - 
Order NAS-Zl. 

1200 W Insertion Unit 1 to 30 MHz - 

Order NAS-Z2. 

120 W Insertion Unit 25 to 200 MHz - 

Order NAS-Z3. 

120 W Insertion Unit 70 to 1000 MHz - 

Order NAS-Z5. 



120 W Insertion Unit 890 to 960 MHz - 

Order NAS-Z6. 

30 W Insertion Unit 890 to 960 MHz, 1710 to 
1880 MHz - Order NAS-Z7 

POWER SENSORS 

Diode Power Sensor, 50 Q - Order NRV-Z1. 
Diode Power Sensor, 50 Q > Order NRV-Z2. 
Diode Power Sensor, 75 Q - Order NRV-Z3. 
Diode Power Sensor, 50 - Order NRV-Z4. 

Diode Power Sensor, 50 Q - Order NRV-Z5. 
Diode Power Sensor, 50 Q - Order NRV-Z6. 
Diode Power Sensor, 50 Q - Order NRV-Z7 
Diode Power Sensor, 50 Q - Order NRV-Z8. 
Diode Power Sensor, 50 - Order NRV-Z15. 

Peak Power Sensor, 50 Q - Order NRV-Z31. 
Thermocouple Power Sensor, 50 Q - 
Order NRV-Z51. 

Thermocouple Power Sensor, 50 - 

1 pW to 100 mW, DC to 26.5 GHz. Order NRV-Z52. 



Thermocouple Power Sensor, 50 Q - 

Order NRV-Z53. 

Thermocouple Power Sensor, 50 Q - 

Order NRV-Z54. 

Diode Power Sensor, 50 Q - Order NRV-Z15. 
Thermocouple Power Sensor, 50 Q - 

Order NRV-Z55. 

For your local Tektronix representative see the list in 
the oack of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



224 POWER METERS 



www.tektronix.com/Measurement/commtest/ 




Signal Generators 



Introduction 

Signal generators are the primary stimulus tool in testing a wide range of compo- 
nents and systems used in wireless communication networks and RF/Microwave 
products. Tektronix offers a wide variety of signal generators to meet your changing 
needs. Generators with performance for digital modulated signals as well as analog 
formats, over the range of 9 kHz to 40 GHz are available. 

Whether your needs are excellent phase noise, low spurious output, flexible digi- 
tal modulation or high value, the signal generators from Tektronix offer you the 
right solution. 

SIGNAL SOURCES OFFERED 

SMIQ 02/03/04/06 Vector Signal Generator 

300 kHz to 6.4 GHz, IQ inputs, flexible digital modulation, CDMA capability, fading 
simulation. 

SME 02/03/03E/06 Digital Signal Generator 

5 kHz to 6 GHz, digital signals for most wireless communication formats, four 
models cover from 5 KHz to 6 GHz. 

SMHU58 Signal Generator 

100 kHz to 4.32 GHz with high signal purity and frequency agility. For all types of 
digital and analog modulation. 

IQSIM Software 

Software tool for creating all types of digital modulation. 

SME-K2 

Software tool for generation of TDMA signals with the SME series generators. 

SMT 02/03/06 

5 kHz to 6 GHz multipurpose RF generators with analog modulation. 

SMP 02/03/04/22 

10 MHz to 40 GHz with high signal purity and output power for microwave system 
testing. 



Contents 

Signal Generators 

Selection Guide 226 

SMIQB 227 

AMIQ 233 

SMR 236 

SMP02/03/04/22 240 

SMT06/03/02 242 

SME 244 



www.tektronix.com/Measurement/comnitest/ 



SIGNAL GENERATORS 



225 



Signal Generators Selection Guide 



Vector Signal Generators 

Tvoe 


Frequency 


Application/Description 


'Tr^ 

SMIQ02B 


5 kHz to 2.2 GHz 


l/Q Modulated generator with unrivalled versatility for digitally 
modulated signal generation. Ideal for use in development, 
type approval testing and production test 


SMIQ03B 

SMIQ04B 

SMIQ06B 


5 kHz to 3.3 GHz 


Same as SMIQ02B with enhanced frequency range 


5 kHz to 4.4 GHz 


Same as SMIQ02B with enhanced frequency range 


5 kHz to 6.4 GHz 


Same as SMIQ02B with enhanced frequency range 


RF Signal Generators 






SME02 


5 kHz to 1.5 GHz 


For digital radio receivers, digital radio network and analog modulation, 
generation of user-programable mobile data generator, 

PRBS generator great ease of operation 


SME03 

SME06 


5 kHz to 3 GHz 


Same as SME02 with enhanced frequency range 


5 kHz to 6 GHz 


Same as SME02 with enhanced frequency range 


SMT02 


5 kHz to 1.5 GHz 


Radar applications, VOR/ILS receiver test, FM broadcast transmitter 
and receiver test. Customized configurations, extremely high signal quality, 
versatile modulation capabilities (e.g. Stereo, VOR/ILS) 


SMT03 

SMT06 


5 kHz to 3 GHz 


Same as SMT02 with enhanced frequency range 


5 kHz to 6 GHz 


Same as SMT02 with enhanced frequency range 


SMGU 


0.1 to 2160 MHz 


High performance generator for all analog in-channel and out of 
channel measurements and LO applications, reference for noise 
measurements, high spectral purity and short frequency setting times 


SMYOl 


9 kHz to 1040 MHz 


Economy class instrument for ail analog receiver and component 
measurements, high signal quality, full featured model with versatile 
modulation and signal generation modes 


SMYn? 


9 kHz to 2080 MHz 


Same as SMYOl with enhanced frequency range 


Mirrnwave Slonal Generators 


SMR20 


1 to 20 GHz 


CW generators with pulse modulation capability. Excellent price 
performance ratio. Options for modulation and analog sweep 
at an affordable price 


SMR27 

SMR40 


1 to 27 GHz 


Same as SMR20 with enhanced frequency range 


1 to 40 GHz 


Same as SMR20 with enhanced frequency range 


SMP02 


0.01/2 to 20 GHz 


Radar and communications receiver test, R&D and EMI Testing. 
High spectral purity, excellent pulse modulation characteristics, 
extensions for specific or universal use 


SMP22 


0.01/2 to 20 GHz 


Same as SMP02 with output level of +22 dBm 


SMP03 


0.01/2 to 27 GHz 


Same as SMP02 with enhanced frequency range 


SMPnd 


0.01/2 to 40 GHz 


Same as SMP02 with enhanced frequency range 


Fiinrtion and ARB Generators 


AMIQ 


2 CH. 100 ms/sec, 14-Blt ARB 


Dual channel l/Q modulation generator. 14-Blt resolution, 

100 MHz sample rate, 4M Samples memory depth 


Software 


WinIQSIM 




Calculation of digitally modulated l/Q and IF signals, multicarrier, 
W-CDMA and CDMA signal, free with AMIQ 


SME-K2 




General data transfer software for SME series instruments 



226 



SIGNAL GENERATORS 



www.tektronix.com/Measurement/commtest/ 



New 

Digital 



Vector Signal 

Signals of Your Choice 



Generator SMIQ 




Features - Benefits Applications 



Frequency Range 300 kHz to 6.4 GHz 
Analog and Digital Modulation 

Versatile and Broadband 
Generation of Digitally Modulated 
Signals up to 7 Msymbol/s 

Generation of TDMA, CDMA and W- 
CDMA Standard Signals to all Main 
Mobile Radio Standards 

Broadband l/Q Modulator with 
Outstanding Vector Accuracy 

Optional Internal Fading Simulator 
to Test Specifications of Mobile 
Radio Standards 

Optional Internal Noise Generator 
and Distortion Simulator 

Low ACP Option for IS-95 CDMA 
and W-CDMA 



Component Development 
Component Manufacturing 
Phone Development 
BTS Development 
Receiver Test 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the (J.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



The new B series of Signal Generator Family 
SMIQ for analog and digital modulation from 
Rohde&Schwarz offers solutions for today and 
tomorrow. This series particularly takes into 
account future developments in the field of third 
generation digital mobile radio. 

The SMIQ family comprises four models which 
differ in their upper frequency limits. These fea- 
ture a hitherto unrivalled versatility regarding 
signal generation and signal quality and are 
therefore ideal for use in development and type- 
approval testing. 

With their outstanding price/performance ratio, 
these signal generators are also economically 
attractive for applications in production. 

The wide frequency range from 300 kHz to 
6.4 GHz covers all main radio bands including 
their IF ranges. 

The high-grade I/Q modulator fitted as standard 
ensirres minimum error vector magnitude and 
high intermodulation suppression. 



Using modern digital signal processor (DSP) 
technology, the versatile concept allows the gen- 
eration of high-precision digital modulation sig- 
nals with high bit rates without any limitations 
on modulation modes or standards. 

In addition to digital modulation, the signal 
generators provide the full range of analog 
modulation modes as well as simultaneous 
modulation capability. 

SMIQ - A Signal Generator 
Family... 

RF CHARACTERISTICS 

► Wide output frequency range from 300 kHz 
to 3.3 GHz 

► High (up to 16 dBm) and precise output level 
(0.5 dB typ.) 

► Fast setting time for frequency (<15 ms) and 
level (<10 ms) 

► Frequency hopping (500 ps) 



www.tektronix.com/Measurement/commtest/ 



SIGNAL GENERATORS 227 







New Vector Signal Generator SMIQ 

DIGITAL SIGNALS OF YOUR CHOICE 



► High spectral purity (-126 dBc/Hz at 
1 GHz and 20 kHz carrier offset) 

► RF, AF and level sweep 
(user-programmable) 

ANALOG MODULATION 

► Broadband AM with up to 30 MHz 
modulation frequency 

► I/Q modulation with 60 MHz RF 
bandwidth (3 dB) 

► Unprecedented vector accuracy and 
high intermodulation suppression 

► Amplitude modulation 

► Pulse modulation 

► Optional frequency and phase 
modulation (SM-B5) 

DIGITAL MODULATION 

ANY DIGITAL MODULATION 
MODES (WITH OPT. SMIQB10) 

► Free choice of modulation mode 
from FSK through to 256QAM 

► Any kind of baseband filtering with 
variable filter parameters 

► Symbol rate adjustable up to 
7 Msymbol/s 

► Real-time coding of internal and 
external data 

► Internal PRBS generators 

CONVENIENT BURST GENERATION 
FOR TDMA STANDARDS (WITH 
OPT. SMIQB10/SMIQB11) 

► TDMA mobile radio standards pro- 
vided as standard GSM, DECT, 

NADC (IS-54C/IS-136), PDC, PHS 

► Versatile external synchronization 
capabilities 

► Real-time processing of external and 
internal data 

► Generation of TDMA frame structures 
with versatile timeslot configuration 

► Continuous PRBS sequences 

► Optimization of burst shaping to 
reduce spectra due to switching 

UP TO 20 MBIT INTERNAL DATA 
MEMORY (WITH OPT. SMIQB12) 

OPTIONAL CDMA STANDARD TO 
IS-95 (OPT. SMIQB42) 

OPTIONAL W-CDMA STANDARD TO 
ARIB (0.0 STANDARD) AND EXPER- 
IMENTAL W-CDMA SYSTEM (OPT. 
SMIQB43) 



...For All Requirements 

SPECIAL OPTIONS 

FADING SIMULATION (OPT. 

SMIQB14 AND SMIQB15) 

► Fading of internal or external I/Q 
signals conforming to mobile radio 
standards 

► 6-path simulation can be enhanced 
to 12-path simulation (12-channel 
fading also possible with second 
vector signal generator) 

► Selectable path attenuation and delay 

► Simulation of high speeds 

► Preprogrammed fading profiles for 
mobile radio standards GSM, NADC, 
IS-95 CDMA and TETRA 

► Frequency range of basic unit can be 
fully utilized 

► Calibrated RF level in range 
from -140 dBm to -5 dBm 

► Unrivalled price/performance ratio 

NOISE GENERATOR AND DISTOR- 
TION SIMULATOR (OPT. SMIQB17) 

► Simulation of amplitude and phase 
distortion (AM/ AM and AM/phi M 
characteristics) 

► Distortion characteristics program- 
mable from up to 30 input values 

► Superimposed noise signals (AWGN) 

► C/N ratio variable with high resolu- 
tion over a wide range 

► Broad noise bandwidth (10 kHz to 
10 MHz) 

LOW ACP FOR IS-95 CDMA AND 

W-CDMA (OPT. SMIQB47) 

► Specially designed for 1.2288 
Mchip/s, 4.096 Mchip/s and 8.192 
Mchips/s 

► Can be used with internal (Opt. 
SMIQB42/43) or external CDMA/W- 
CDMA signals 

► Typical W-CDMA adjacent-channel 
power ratio (5 MHz off-set, 4.096 
Mchip/s): -68 dBc (1 DTCH) 

► Typical IS-95 CDMA adjacent-channel 
power ratio (885 kHz off-set): —78 dBc 
(9 code channels) 

FAST CPU (OPT. SM-B50) 

► Reduction of firequency and level set- 
ting times to one fifth (3 ms and 2 ms) 

► Option required in conjunction with 
fading (SMIQB14/15) and distortion 
simulation (SMIQB17) 



Outstanding RF 
Characteristics 

FROM 300 KHZ TO 3.3 GHZ 

With its wide frequency range, the 
SMIQ family has the right model for 
every application. The uppermost fre- 
quency limit of 3.3 GHz leaves suffi- 
cient margin even for WLL (wireless 
local loop) systems. Frequency exten- 
sion options allow upgrading to higher 
frequency limits. 

LEVEL - HIGH AND PRECISE 

With an output level of maximum +13 
dBm (+16 dBm in overrange) insertion 
losses caused by cables or switching 
matrices can easily be compensated. For 
driving components with high input 
level the use of an external amplifier is 
not necessary. 

A level accuracy of typ. ±0.5 dB 
allows high-precision measurements 
even on highly sensitive analog and 
digital receivers. 

EXCELLENT SPECTRAL PURITY 

SMIQ provides output signals of excel- 
lent spectral purity. Low-noise frequen- 
cy synthesis ensures modulation of 
highest quality for reliable test signals. 

FAST SETTING TIMES 

Fast setting times are among the most 
important criteria when it comes to 
choosing the right signal generator, 
especially in production. 

The synthesizers of the SMIQ family 
excel in this respect: with a frequency 
setting time of less than 15 ms they 
allow extremely fast measurements. 
With option SM-B50 (fast CPU) the fre- 
quency setting time is reduced to 3 ms. 

Besides standard sweep functions for 
RF, AF and level, SMIQ features an 
extremely versatile and fast sweep 
mode for frequency and level settings to 
be carried out with the aid of stored 
lists. This mode with a setting time of 
less than 500 ps is ideal for frequency 
hopping applications. 

LOW COST OF OWNERSHIP 

The use of high-precision reference ele- 
ments with long-term stability ensures 
reliable operation over a long period of 
time. The three-year calibration inter- 
vals cut costs and increase availability. 



228 SIGNAL generators 



www.tektronix.com/Measurement/commtest/ 



New Vector Signal Generator SMIQ 

DIGITAL SIGNALS OF YOUR CHOICE 



(Left) Typical level accuracy at 0 dBm. 

(Right) Typical I/Q frequency response. 
(Bottom) Typical SSB phase noise at fc =1 GHz. 



DESIGNED FOR THE FUTURE 

The open concept of SMIQ allows the 
functionality of the signal generator to 
be adapted to future requirements in a 
simple and cost-effective way. 

Since SMIQ uses programmable digital 
signal processing chips throughout, its 
capabilities are not limited by the hard- 
ware used. 

New functions can be downloaded 
very simply via the serial interface of 
the generators. 

THREE WAYS OF GENERATING 
DIGITAL SIGNALS 

Vector Signal Generators SMIQ can gen- 
erate digitally modulated signals in 
three different ways. 

1. Vector Modulation 

In this mode, externally generated I/Q 
signals are applied to the I/Q modulator 
of SMIQ. I/Q Modulation Generator 
AMIQ together with Simulation 
Software WinIQSIM are perfect tools for 
the generation of external I/Q signals. 

2. Digital Modulation 

The universal modulation coder 
(SMIQBlO) and data generator 
(SMIQBll) options provide a platform 
for generating digitally modulated sig- 
nals that are variable in a wide range. 
Modulation mode, filtering, data 



source and symbol rate can be selected 
by the user. 

3. Digital Standards 

The digital standards provide at a key- 
stroke base-station and mobile-station 
signals to telecommunication 
standards - based on the capabilities of 
the optional digital modulation coder 
(SMIQBlO). The TDMA (time division 
multiple access) standards GSM, DECT, 
NADC (IS-54C, IS-136), PDC and PHS 
come with the optional data generator 
(SMIQBll). The CDMA (code division 
multiple access) standard IS-95 
(SMIQB42) or W-CDMA (SMIQB43) are 
also available as an option. The number 
of future digital standards that can be 
simultaneously accommodated in SMIQ 
is unlimited. 

Digital Modulation 

DIGITAL STANDARDS 

SMIQ, fitted with the modulation coder 
(SMIQBlO) and data generator 
(SMIQBll) options, provides standard- 
conformal signals for testing mobile and 
base stations of the main mobile radio 
networks. These test signals contain the 
necessary protocol information and 
frame structures for testing receivers. 

The timeslots (bursts) and their data 
contents can be specified for the TDMA 



standards GSM, DECT, NADC, PDC and 
PHS via user-friendly menus. The main 
burst types are predefined and available 
at a keystroke. They can easily be modi- 
fied, stored and reused for tests. 



Continuous PRBS data streams and 
internally generated data lists as well as 
externally provided serial data streams 
can be inserted in real-time into the 
data fields of the frame structures. 






GSM Global System for Mobile 
Communication 



Frames and timeslot configuration 
conform to the GSM standard. Each 
time-slot (burst) has a certain data 
structiue depending on its use, e.g., 
as traffic channel or channel for 
frequency synchronization. 

DECT Digital Enhanced Cordless 
Telecommunication Standard 

This operating mode allows signals to 
be generated to ETSI DECT standard. 



NADC North American Digital Cellular 
(IS-54, IS-136) 

The data protocol structure conforms to 
NADC specifications IS-54 and IS-136. 
The following predefined burst types 
are available: uplink burst, downlink 
burst, all data. 

PDC Personal Digital Cellular (RCR 
STD-2 7C) 

The data protocol structure conforms 
to PDC specification RCR-27C. This 
standard is largely identical with the 
NADC standard. 

PHS Personal Handy Phone System 
(RCR STD-28) 

The data protocol structure conforms to 
PHS specification RCR-28. The follow- 





www.tektronix.com/Measurement/commtest/ 



SIGNAL GENERATORS 229 



New Vector Signal Generator SMIQ 

DIGITAL SIGNALS OF YOUR CHOICE 



ing predefined burst types are provided: 
control physical slot, communication 
physical slot, sync, TCH, VOX, all data. 

CDMA IS-95 Code Division Multiple 
Access (with Opt. SMIQB42) 

For the CDMA base-station signal (for- 
ward link) up to 64 code channels can 
be generated with user-selected Walsh 
codes. The power of the code channels 
can be selected independently for up to 
four channels. The channel data con- 
sist of various internal PRBS or fixed 
data patterns. 

The mobile-station signal (reverse link) 
can be configured for full-rate as well as 
for half-rate operation. Moreover it is 
possible to generate a channel-coded 
reverse-link signal. 

W-CDMA Wideband Code Division 
Multiple Access (with Opt. SMIQB43) 

W-CDMA - a “standard” currently still 
in the definition phase — is one of the 
favored technologies for the third mobile 
radio generation. Rohde&Schwarz, 
known as a trendsetter in the field of 
mobile communication test and meas- 
urement, is already able to offer signal 
generation capabilities for this mobile 
radio standard of the future. 

Fitted with option W-CDMA 
(SMIQB43), SMIQ is able to generate W- 
CDMA signals to the Japanese specifica- 
tions of NTT DoCoMo and ARIB*^. 

Like with lS-95 CDMA, uplink (mobile 
station to base station) and downlink 
(base station to mobile station) can be 
simulated with up to 15 code channels. 
A chip rate of 4.096 Mchip/s is preset, 
but can be varied any time. 

There is a choice of different types of 
physical channels, such as perch, com- 
mon control or dedicated physical chan- 
nels. The frame structure consisting of 
various data fields (traffic power control 
or long code mask symbol) is automati- 
cally generated for each type of channel. 

Association of Radio Industries and 
Businesses (ARIB), Specifications of Air 
Interface for a 3 G Mobile System. 

Special Options 

FADING SIMULATION - OPTIONS 
SMIQB14/B15 

With the optional fading simulator, the 
SMIQ models are the first signal genera- 

230 SIGNAL GENERATORS 



tors allowing tests that correspond to the 
capabilities of conventional simulators. 
Fading is thus no longer a matter of high- 
ly speciahzed measurement technology. 

Fading simulation in SMIQ is based on 
the WSSUS (wide sense stationary 
uncorrelated scattering) model and 
meets the test specifications of all main 
mobile radio standards, such as GSM 
Rec. 05.05. Both internal and external 
I/Q baseband signals are provided with 
defined multipath propagation factors 
through digital signal processing. 
Conversion to the RF with calibrated 
level setting is made with the available 
hardware of SMIQ. 




Characteristics 



RF Features 

Frequency 

Range - 

SMIQ02B: 300 kHz to 2.2 GHz. 

SM1Q03B: 300 kHz to 3.3 GHz. 

SMIQ04B: 300 kHz to 4.4 GHz. 

SMIQ06B: 300 kHz to 6.4 GHz. 

Resolution - 0.1 Hz. 

Setting time to within <1x10"’ for f>450 MHz 
and <240 Hz for f<450 MHz after lEC/IEEE-bus 
delimiter: 

Standard: <15 ms. 

With Opt. SM-B50: <3 ms. 

Phase offset - adjustable in steps of 0.1°. 



Reference Frequency 

Aging (After 30 Days of Operation) - 

Standard: lxl0"*/year. 

Option: SM-Bl:<lxlO-7day. 

Temperature Effect (0°C to 50°C) - 

Standard: 2x10®. 

Option: <5x10'®. 

Level 

Range - -140 dBm to +13 dBm (PEP)*'. 
Overranging without guarantee of specs: up 
to 16 dBm. 

Resoiution - 0.1 dB. 

Totai Measurement Uncertainty 
-127 dBm**' * - 

f<2GHz:<±l dB. 
f>2 GHz: <±1.5 dB. 

Frequency Response at 0 dBm**' * - typ. 
<0.3 dB. 

Spectral Purity** 

Spurious - 

Harmonics at levels <10 dBm: <-30 dBc. 
Nonharmonics. 

CW, carrier offset <10 kHz. 

0.3 to 450 MHz: <-74 dBc. 

>450 to 1500 MHz: <-80 dBc. 

>1500 to 3000 MHz: <-74 dBc. 

>3000 MHz: <-60 dBc. 

Vector modulation: 

Carrier offset 10 kHz to <300 MHz: <-70 dBc. 
Carrier offset >300 MHz: <-60 dBc (typ. 
<-65 dBc). 

Broadband Noise, CW, Carrier 
Offset >5MHz - 

f = 20 MHz: <-135 dBc (typ. -140 dBc). 
f = 3 GHz: <-130 dBc (typ. -135 dBc). 

Broadband Noise, Vector Modulation, 
f >-135 dBc). 

SSB Phase Noise, Carrier Offset 20 kHz, 

I Hz Bandwidth - 

f = 20 MHz to 450 MHz - CW: <-116 dBc 
Vector/dig. mod.: <-119 dBc. 
f=l GHz -CW: <-126 dBc 
Vector/dig. mod.: <-123 dBc. 
f = 2GHz-CW: <-120 dBc 
Vector/dig. mod.: <-120 dBc. 
f = 3GHz-CW: <-116 dBc 
Vector/dig. mod.: <-116 dBc. 

Residual FM, rms (f = I GHz) - 
0.3 to 3 kHz (ITU-T): <1 Hz. 

0.03 to 20 kHz: <4 Hz. 

Residual AM, rms (0.03 to 20 kHz) - 
<0.02»/o. 



www.tektronix.com/Measurement/comiiitest/ 





New Vector Signal Generator SMIQ 

DIGITAL SIGNALS OF YOUR CHOICE 



Modulation with Coding 

The table below shows the possible combinations of modulation with coding (X = combination possible). 





Coding off 


Differential 


Differential 

phase 


Differential 

Gray 


GSM 


NADC PDC PHS, TFTS/ 

TETRA, APC025, PWT TETRA 


INMARSAT VDL 


BPSK 


X 


X 




X 








QPSK 


X 


X 




X 






X 


QPSK (IS-95) 


X 


X 




X 






X 


INMARSAT 


X 


X 




X 






X 


QPSK ICO 


X 


X 




X 






X 


OQPSK 


X 


X 




X 






X 


OQPSK (IS-95) 


X 


X 




X 






X 


pj/4QPSK 


X 














PI/4QPSK 


X 










X 




8PSK 


X 


X 




X 






X 


8PSK_EDGE 


X 


X 




X 






X 


2FSK 


X 


X 




X 


X 






4FSK, 
















4FSK,APC0 


X 






X 








GFSK 


X 


X 




X 


X 






GMSK 


X 


X 




X 


X 






16QAM 


X 


X 


X 


X 








32QAM 


X 


X 


X 


X 








64QAM 


X 


X 


X 


X 








256QAM 


X 




X 











Modulation with Filtering 

The table below shows the possible combinations of modulation with filtering (X = combination possible). 







cos 


Gauss 


Gauss Lin 
BT=0.3 


Bessel 

BT=2.5 


Bessel 

BT=1.26 


IS-95 


IS-95 Equal 


APCO 

C4FM 


TETRA 


Rectangular 


W-CDMA 


BPSK 


X 


X 




X 






X 


X 




X 


X 


X 


QPSK 


X 


X 




X 






X 


X 




X 


X 


X 


QPSK (IS-95) 


X 


X 




X 






X 


X 




X 


X 


X 


INMARSAT 


X 


X 




X 










X 




X 


X 


QPSK ICO 


X 


X 




X 










X 




X 


X 


OQPSK 


X 


X 




X 














X 


X 


OQPSK (IS-95) 


X 


X 




X 














X 


X 


pj/4QPSK 


X 


X 




X 












X 


X 


X 


pi/4 QPSK 


X 


X 


X 


X 












X 


X 


X 


8PSK 


X 


X 


X 


X 












X 


X 


X 


8PSK_EDCE 


X 


X 


X 


X 












X 


X 


X 


2FSK 


X 


X 


X 


X 


X 


X 








X 


X 


X 


4FSK, 


























4FSK, APCO 


X 


X 


X 


X 


X 


X 








X 


X 


X 


GFSK 






X 


X 












X 


X 




GMSK 






X 


X 












X 


X 




16QAM 


X 


X 




X 






X 


X 




X 


X 


X 


32QAM 


X 


X 




X 






X 


X 




X 


X 


X 


64QAM 


X 


X 




X 






X 


X 




X 


X 


X 


256QAM 


X 


X 




X 






X 


X 




X 


X 


X 



www.tektronix.com/Measurement/commtest/ 



SIGNAL GENERATORS 231 



New Vector Signal Generator SMIQ 

DIGITAL SIGNALS OF YOUR CHOICE 



Overview of Digital Standards 

The table below summarizes the key data for the digital TDMA standards implemented in SMIQ. Options SMIQBIO and SMIQB11 are required for all 
standards. 





GSM 


DEQ 


NADC 


PDC 


PHS 


Error vector magnitude. 


N/A 


N/A 


<1.2% 


<1.2% 


<1.2% 


rms (standard, <7 dBm PEP) 






typ. 0.4% 


typ. 0.4% 


typ. 0.4% 


Phase Error (standard, <7 dBm PEP) 






N/A 






rms 


<r 










typ. 0.3° 














m 


N/A 


m 


N/A 




Peak value 


>3°, typ. r 










Deviation error, rms (standard) 


N/A 


<1.3% 


N/A 


N/A 





Channel spacing/kHz 


200 


1728 


30 


25 


300 


Power density spectrum, typ. 












(standard level <7 dBm PEP, resolution 












BW 30 kHz 












Offset 200 kHz 


-34 dB 




N/A 


N/A 


N/A 


400 kHz 


-70 dB 










600 kHz 


-78 dB 










Adjacent-channel power (ACP), typ. 












at adjacent channel 


N/A 




-35 dB 


- 


- 


At 1st alternate channel 




N/A 


-75 dB 


-74 dBc 


-74 dBc 


At 2nd alternate channel 






-78 dB 


- 


-76 dBc 


At 3rd alternate channel 






- 


-78 dBc 


- 


Burst types 


NORMAL 


FULL (basic) 


up/down 


TCH, SYNC, 


TCH (32 kbit 




DUMMY 


DOUBLE (high capacity). 


TCH,ALL 


VOX, 


and 16 kbit). 




ALL DATA 


ALL DATA 


DATA 


ALL DATA 


SYNC, VOX, 








Up SHORT 




ALL DATA 



your local Tektronix representative, inside the U.S. see 



Ordering Information 



For price information: Outside the U.S. contact 

SMIQ02B 

Vector Signal Generator 300 kHz to 2.2 GHz. 
Includes - Power Cord, Operating Manual. 

SMIQ03B 

Vector Signal Generator 300 kHz to 3.3 GHz. 

SMIQ04B 

Vector Signal Generator 300 kHz to 4.4 GHz. 

SMIQ06B 

Vector Signal Generator 300 kHz to 6.0 GHz. 
Includes - Power Cord, Operating Manual. 

Opt. B1/SM-B1 - OXCO reference oscillator. 

Opt. B5/SM-B5 - FM phase modulation. 

Opt. B10/SMIQ-B10 - Modulation coder. 

Opt. B11/SMIQ-B11 - Data Generator. 

Opt. B12/SMIQ-B12 - 8 Mbit memory extension. 
Opt. B14/SMIQ-B14 - Fading Simulator six paths 
(Requires Opt. B50). 



Opt. B15/SMIQ-B15 - 2nd fading simulator 12 
paths or two channels (Requires Opt B50). 

Opt. B17/SMIQB17 - Noise Generator and 
Distortion Simulator (Requires Opt B50). 

Opt. B19/SMIQ-B19 - RF and LF rear panel 
connectors. 

Opt. B42/SMIQ-B42 - CDMA IS-95. 

Opt. B43/SMIQ-B43 - W CDMA. 

Opt. B47/SMIQ-B47 - Low ACP for IS-95 CDMA 
and W-DCMA. 

Opt. U47/SMIQ-U47 - Modification Kit for Low ACP. 
Opt. B50/SMIQ-B50 - High speed CPU. 

Opt. U50/SM-U50 - Modification Kit, High 
Speed CPU. 

Opt. 1R - ZZA94 rack mount adapter. 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of Calibration Services. 

Opt. D1 - Cal Data Report 

Opt. D3 - Test data (requires Opt. C5). 



the price list in the back of this catalog. 

Opt. R3 - Repair warranty extended to cover 
three years. 

Rackmount for 19 in. Rack - Order ZZA-94. 
Service Kit - Order SM-Z3. 

SMIQ-Z5 - BNC Adapter for rear panel, D type con- 
nector PAR DATA. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916. inside the U.S. call: 1-800-426-2200. 

Product(s) available through your local Tektronix 
Distributor listed in the back of this catalog. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



232 SIGNAL GENERATORS 



www.tektronix.com/Measurement/commtest/ 




I/Q Modulation Generator 
Simulation Software 

"t.. New AMIQ/I/Q • WinIQSIM 




Features - Benefits Applications 



AMIQ 

14-Bit Resolution 

4,000,000 Samples Memory Depth 
100 MHz Sample Rate 

Integrated Hard Disk and Floppy 
Disk Drive 

Optional BER Measurement 

WINIQSIM 

Calculation of Digitally Modulated 
I/Q and IF Signals 

Single-carrier, Multicarrier and 
CDMA Signals 

Versatile Data Editor 

Superposition/Simulation of 
Impairments 

Graphic Display 
CDMA and W-CDMA 



Verification/Type-approval Testing 
of Digital Mobile Phones and Base 
Stations 

-For Verification and Type 
Approval of Mobile Phones and 
Base Stations Signal 

Use in ATE (Automatic Test 
Equipment) Systems 
-AMIQ Is an Ideal Choice as a 
Baseband or IF Signal Source 

Development of New 
Communication Systems 

Third-generation Communication 
Systems, TDMA, CDMA, W-CDMA 
-Signals as Used by Novel and 
Future Communication Systems, 
e.g, CDMA or W-CDMA, As Well 
As by Wireless Local Loop or 
Wireless LAN Systems Can Be 
Generated with Little Effort 
Using AMIQ and WinIQSIM 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call; 
1-800-426-2200. 



New Approaches in the Generation 
OF Complex I/Q Signals 

HIGH SAMPLING RATE 

► 100 MHz clock rate 



C€ 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



► Up to 4,000,000 samples memory capacity 

► Generation of broadband digital communica- 
tion signals (e.g. W-CDMA) 

STORED WAVEFORMS FOR RECALL 

► Built-in hard disk for storage of calculated 
signals 

► Downloading of calculated waveforms and 
signals also from integrated floppy disk drive 



PRECISE SIGNALS 

► Anti-aliasing filters featuring excellent fre- 
quency response and constant group delay 

► Autoalignment and additional user correction 
of amplitude and offset 

► Fine adjustment of I/Q skew 

► Wide dynamic range by use of 14-Bit D/A 
converter, ideal for multicarrier applications 



www.tektronix.com/Measurement/commtest/ 



SIGNAL GENERATORS 233 





1/Q Modulation Generator Simulation Software 

NEW AMIQ/I/Q • WINIQSIM 



AMIQ/WinIQSIM - An Ideal 
Pair 

The number of systems based on com- 
plex digital modulation methods has 
dramatically increased in every field of 
communications. I/Q modulation is 
thus gaining in importance for the 
development of such new modulation 
methods. Modulation Generator AMIQ 
and Simulation Software WinlQSIM 
open up new dimensions for the gener- 
ation of I/Q signals. 

AMIQ is a dual-channel modulation 
generator that has been designed for use 
as an I/Q source. It is programmed with 
Software WinlQSIM. Alternatively, 
AMIQ can be operated from a Vector 
Signal Generator SMIQ. 

Each chcmnel can store 4,000,000 sam- 
ples. Even at high symbol rates 
sequences of sufficient length can thus 
be generated. With clock frequencies of 
up to 100 Msample/s and a high ampli- 
tude resolution of 14 bits, AMIQ is the 
ideal source for any signal in the world 
of digital modulation. 

An automatic amplitude/offset align- 
ment as well as fine adjustment of the 
skew provide excellent symmetry of the 
two channels which previously was 
extremely difficult to attain with dual- 
channel ARB generators. The error vec- 
tor can thus be minimized. 

The filters have also been optimized 
regarding group delay, frequency 
response and identical configuration in 
the two channels for use as an 1/Q 
modulation source. 

A typical application of AMIQ and 
WinlQSIM is not only to drive the I/Q 
inputs of a vector signal generator. This 
combination is also ideal for direct 
applications in the baseband, e.g. for 
testing I/Q modulators/demodulators. 



...THE Ultimate in IQ Signals 

I/Q SIMULATION SOFTWARE... 

► Single-carrier signals 

► Multicarrier signals (up to 512 mod- 
ulated or unmodulated carriers) 

► CDMA signals with user-selectable 
number of code channels 

► Addition of impairments 

► Data editor for creating any TDMA 
frame configuration 

► Predefined files for TDMA mobile 
radio standards (GSM, DECT, NADC 
(IS54C/IS136), PDC, PHS) 

► IF signal calculation 

► Graphic display of calculated signals 
(constellation diagram, vector dia- 
gram, i(t)/q(t), magnitude and phase, 
eye pattern, etc) 

► Remote control of AMIQ 
Modulation methods like GMSK or 
pi/4DQPSK are used in mobile commu- 
nication systems such as GSM (Global 
System for Mobile Communications) or 
NADC (North American Digital 
Cellular). These complex modulation 
modes are usually generated with the 
aid of an I/Q or vector modulator. The 
calculation and generation of the 
required baseband signals is of course 
quite complex. 

WinlQSIM, successor of the well- 
proven IQSIM, is a Windows software, 
allowing calculation of I and Q base- 
band signals. Its capabilities range 
from single-carrier modulation, genera- 
tion of multicarrier, CDMA and W- 
CDMA signals through to TDMA frame 
configurations with the help of a con- 
venient data editor. All modulation 
parameters and impairments can be 
simulated for single-carrier and multi- 
carrier as well as for CDMA signals. To 
put it in a nutshell: WinlQSIM is an 
indispensable tool for anyone engaged 
in modern digital modulation. 

SINGLE CARRIER 

Modulation parameters such as type 
of modulation, coding, symbol rate, 
filter and window functions as well 
as oversampling can be set for a 
single-carrier signal. 



Impairments which may be caused by a 
real I/Q modulator are also taken into 
consideration. It is for instance easy to 
simulate I/Q imbalance, carrier leakage 
or quadrature error. The simulation of 
VCO noise or phase and frequency off- 
sets of an oscillator is one of the very 
special features of WinlQSIM. These 
and many other setting possibilities 
enable the user to take account of real 
impairments as early as in the develop- 
ment of components and modules. But 
also for applications in production 
environments signals can be composed. 
Such signals allow several parameters 
to be tested at a time and thus testing 
time to be reduced dramatically. 

OPTION AMIQ B2: DIFFERENTIAL 
OUTPUTS FOR THE AMIQ ARBITRARY 
WAVEFORM GENERATOR 

As more components and subsystems 
are provided with balanced I/Q inputs, 
there is a need to directly provide this 
stimulus to devices such as mixers and 
modulators. In the past, customers have 
developed custom circuits to provide 
differential inputs to their DUT. AMIQ 
option B2 provides 4 outputs on the 
front panel of the AMIQ for differential 
stimulus. I, —I, Q and -Q can all be 
independently varied in DC offset for 
exacting differential drive matching. DC 
offset bias can be varied up to ± 2.5 V. 



Characteristics 



OUTPUT MEMORY 

Waveform Length (Data and Markers) - 

Clock rate mode 1 (10 Hz to 4 MHz): 24 to 
4,000,000 samples in steps of one. 

Clock rate mode 2 (2 to 100 MHz): 24 to 
4,000,000 samples in steps of four. 

Amplitude Resolution - 14 bits. 

Marker Outputs - 4. 

CLOCK GENERATION 
Clock Rate - 

Mode 1 (slow): 10 Hz to 4 MHz. 

Mode 2 (fast): 2 MHz to 100 MHz. 

Setting Range - 10 Hz to 105 MHz*L 

Resolution - lxl0~l 

Specs not guaranteed for clock >100 MHz, 
max. ambient temperature 35°C. 



SIGNAL generators 



www.tektronix.com/ Measurement/ commtest/ 



234 





I/Q Modulation Generator Simulation Software 

NEW AMIQ/I/Q • WINIQSIM 



SIGNAL OUTPUT 

Number of Outputs - 2 (I and Q). 

Output Impedance - 50 Q. 

Output Voltage (Vp into 50 Qs) - 

Fix mode: 0,5 V, same for both channels. 

Amplitude fine variation: ±10%, separately 
for each channel. 

Resolution: 0.01%. 

Level difference between the two channels: 
<0.2% (at 1 kHz, after auto-alignment). 

Residual DC offset: <0.5 mV, typ. 0.1 mV 
(after auto-alignment). 

DC fine variation: typ. ±30 mV. 

Resolution: 30 pV. 

SFDR (sinewave 1 MHz, clock rate 10 MHz): 
>70 dB, typ. 80 dB. 

Variable mode: 0 mV to 1 V, separately 

adjustable for each channel. 

Resolution: 3 digits. 

Residual DC offset: <5 mV, typ. 1 mV (after 
auto-alignment). 

DC fine variation: typ. ±70 mV. 

Resolution: 70 pV. 

SFDR (sinewave 1 MHz, clock rate 10 MHz): 
>50 dB (level >0.1 V), typ. 70 dB (level >0.5 
V) Skew between I and Q channel (filter off, 
clock rate 10 MHz, fix mode). 

Skew Between I and Q Channel (Filter Off, 

Clock Rate 10 MHz, Fix Mode) - 

Fine variation typ.: ±1 ns. 

Resolution: <10 ps. 

Effective Bits (Sinewave 5 MHz, Clock 

Frequency 50 MHz, Fix Mode) - Typ. 11. 

Rise Time - Typ. 5 ns. 



BER (OPTION AMIQ-B1) 

Data supplied by the DUT can be compared 
with a nominal random bit sequence; the 
results are transferred to the host computer 
(via the currently used remote control). 
Pseudo random bit sequences: 2 ^-1, 2 ”-l, 2 
^ 5-,2 20 - 1 , 2 23 - 1 . 

Clock source: supplied by DUT, each valid bit 
requires a clock. 

Clock rate: max. 40 MHz. 

Interface: 9-pin sub-D connector. 

Data: TTL. 

Clock: m. 

Setup time: 10 ns. 

Hold time: 2 ns. 

Polarity: normal and inverted (data, clock). 
Measurement results: BER in ppm, not syn- 
chronized, no clock from DUT. 



TECHNICAL SPECIFICATIONS FOR 
DIFFERENTIAL OUTPUTS (OPTION 
AMIQ-B2)i 

Number of Outputs - 4 (I, -I, Q and -Q). 
Output Configuration - Selectable between 
Single and Differential (50 Q or high Z). 

Bias Voltage (EMF, to Ground) - independ- 
ently adjustable for both Channels l(-l) and 
Q(-Q). 

Range: -2.5 V to +2.5 V (±10 mV). 

Resolution: < 1.5 mV. 

Level Difference between I and -I, Q and -Q 
respectively: < 0.5% + 1.5 mV. 

Output Voltage - (Upeak, EMF, between out- 
puts I and -I, Q and -Q respectively. If not 
mentioned otherwise). 

Fix Mode: 2 V, identical for all outputs. 

Level Difference I <-> Q: <0.5% @ 1 kHz, 
after auto-alignment. 

I <-> -I ( Q <-> -Q):<0.5% @ 1 kHz, after 
auto-alignment. 

Residual DC offset: <1 mV (to ground, after 
auto-alignment). 

DC fine variation: typ. ±120 mV. 

Resolution: 120 pV. 

Variable Mode: 0 mV to 4 V, for both Channels 
I and Q independently selectable. 

Resolution: 3 digits. 

DC fine variation: typ. ±280 mV. 

Resolution: 280 pV. 

Maximum Output Voltage (U«g„ai + Uyas): 

<2.5 V (to ground). 



Physical Characteristics 



Dimensions 


in. 


mm 


Width 


16.8 


427 


Height 


3.5 


88 


Depth 


17.7 


450 


Weight 


lb. 


kg 


Net 


18.5 


8.4 



Ordering Information 



For price information: Outside the U.S. contact 

AMIQ 

I/Q Modulation Generator. 

Includes: WinIQSIM version for Windows 3.x and 
Windows 95/NT on CD-ROM, manual, power cable, 
operating manual. 



your local Tektronix representative, inside the U.S. 

OPTIONS 

Opt. B1 - BER Measurement. 

Opt. B2 - Differential Outputs for AMIQ. 

Opt. K-ll- IS-95 cdma for WinIQSIM. 

Opt. B19 •* - Rear I/Q Outputs. 

RECOMMENDED ACCESSORIES 
19 in. Rack Adapter - Order ZZA-211. 



the price list in the back of this catalog. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916. inside the U.S. call: 1-800-426-2200. 

C€ 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



www.tektronix.com/MeasuremenVcomintest/ 



SIGNAL GENERATORS 235 





New Microwave Signal Generator SMR 

High-performance, Cost-effective and Reliable up to 40 GHz 





Features - Benefits Applications 



Instrument Family with 3 Models: 
-SMR20 10 MHz to 20 GHz 
-SMR27 10 MHz to 27 GHz 
-SMR40 10 MHz to 40 GHz 

Standard Version: CW Generator 
With Pulse Modulation and Digital 
Frequency Sweep 



Lab Production 

Service 

Research 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



The Allrounder - Designed for 
Future-proofness 

HIGH, LEVELED OUTPUT POWER 

► SMR20 >+10 dBm (at 20 GHz) 

► SMR27 >+11 dBm (at 27 GHz) 

► SMR40 >+9 dBm (at 40 GHz) 

THREE INSTRUMENTS IN ONE 

► CW generator with pulse modulation 
capability (standard version) 

► Signal generator with AM, FM and LF 
generator (option SMR-B5) 

► Synthesized sweeper with analog ramp 
sweep (option SMR-B4) 



CW, Signal Generator or 
Synthesized Sweep Generator... 

SMR AS CW GENERATOR 

The SMR family comprises three basic models 
designed as CW generators with pulse modula- 
tion capability. The three models have a com- 
mon lower frequency limit of 1 GHz and provide 
frequency coverage up to 20 GHz (SMR20), 

27 GHz (SMR27) and 40GHz (SMR40). The lower 
limit can be expanded to 10 MHz by the optional 
Frequency Extension 0.01 to 1 GHz (SMR-Bll). 

Offering an excellent price/performance ratio, 
each of the three basic models is ideal for the 
user wishing to enter the field of microwave test- 
ing at an affordable price. Should measurements 
become more demanding - no problem with 
SMR: all basic models can be upgraded fast and 
easily by means of options to give a signal gener- 
ator with AM/FM modulation capability or a 
synthesized sweep generator featuring fast, fully 
synthesized analog ramp sweep. 



236 



SIGNAL generators 



www.tektronix.com/Measurement/commtest/ 




New Microwave Signal Generator SMR 

HIGH-PERFORMANCE, COST-EFFEaiVE AND RELIABLE UP TO 40 GHZ 



dBc4te 




<30.0 

1400- 



2 468 2 468 2 468 2 488 2 468 

lOH? 100H7 1km lOkH? 100km 1 MH 



SSB phase noise at 10 GHz. 

Excellent Spectral Purity 

SMR stands out from other generators 
for its excellent spectral purity. 
Advanced frequency synthesis with frac- 
tional-N divider makes for low SSB 
phase noise and high spurious suppres- 
sion, both of which are for example pre- 
requisites for reliable receiver measure- 
ments. Modern microwave filters in the 
output path of the instrument ensure 
excellent harmonics suppression. This is 
necessary to obtain conclusive results in 
scalar network analysis measurements. 

Stable Output Frequency 

The crystal reference built in as stan- 
dard ensures an accurate, low-drift out- 
put frequency. SMR can be fitted with 
the optional OCXO Reference Oscillator 
SMR-Bl to satisfy the most stringent 
requirements on accuracy and aging. 

Application-oriented Frequency 
Resolution 

The standard frequency resolution of 1 
kHz of SMR offers a comfortable margin 
for most applications, for example fre- 
quency response measurements in the 
laboratory and in production and servic- 
ing. To satisfy more stringent require- 
ments, e.g. for scientific applications and 
research, option SMR-B3 is available to 
improve frequency resolution to 0.1 Hz. 



www.tektronix.com/Measurement/commtest/ 



Pulse Modulator Included 

Pulse modulation is still the most 
important modulation mode for 
microwave applications. So, each of our 
basic units is equipped with a high- 
quality pulse modulator. The on/off 
ratio is better than 80 dB, the rise/fall 
time shorter than 10 ns. Pulse widths of 
less than 20 ns are possible. These guar- 
anteed values make SMR ideal for use 
in the development, production and 
maintenance of radar equipment. 

Pulse Generator Option 

The optional Pulse Generator SMR-Bl 4 
is an ideal complement to the pulse 
modulator. It generates single and dou- 
ble pulses with pulse frequencies up to 
10 MHz. The pulse generator can also 
be triggered externally and operated in 
the external gate mode. The pulse 
width and delay are freely selectable 
over a wide range. 

SMR AS SIGNAL GENERATOR 

The optional AM/FM/SCAN Modulator 
SMR-B5 added to the basic models turns 
them into fully-fledged signal generators 
TAuth AM and FM modulation capability. 
The option also includes an LF generator 
for sinewave and squarewave signals in 
the range 0.1 Hz to 10 MHz. 

FM and FSK 

The FM modulator has a modulation 
bandwidth from DC to 5 MHz. Digital 
frequency shift keying (FSK) is possible 
with data rates from 0 to 2 MHz. 




Typical max. output level as a function 
of fi-equency. 

SMR AS SYNTHESIZED SWEEP 
GENERATOR 

Analog Ramp Sweep Option 
The analog ramp sweep mode corre- 
sponds to the analog sweep of classical 
sweep generators except that the sweep 
is fully synchronized over the complete 
range. In this way, the excellent frequen- 
cy accuracy of digital step sweeps is 
achieved on the whole, and this at much 
higher sweep rates of up to 600 MHz/ms. 
In conjunction with scalar network ana- 
lyzers or suitable spectrum analyzers, 
real-time adjustment of microwave filters 
can be performed. 

To mark important frequency ranges 
such as filter bandwidths or the position 
of attenuation poles, SMR has 10 user- 
selectable frequency markers which can 
be output as pulse markers at the mark- 
er output (HCT/TTL level) or alterna- 
tively modulated on the RF level as 
level markers (level reduction of 1 dB). 

The use of SMR in conjunction with a 
scalar network or spectrum analyzer is 
illustrated by the figure below. 

SMR AS UPCONVERTER 

IF Input Option 

Vector signal generators like SMIQ gener- 
ate all types of digitally modulated sig- 
nals up to RF frequencies of 6.4 GHz. To 
generate digitally modulated signals up to 
40 GHz, SMR offers upconversion capa- 
bility by means of the IF input option. 



SIGNAL GENERATORS 237 



New Microwave Signal Generator SMR 

HIGH-PERFORMANCE, COST-EFFEaiVE AND RELIABLE UP TO 40 GHZ 



Characteristics 



FREQUENCY / 

Range (SMR20) - 

Without Opt. SMR-B11: 1 GHz to 20 GHz. 

With Opt. SMR-B11: 10 MHz to 20 GHz. 

Range (SMR40) - 

Without Opt. SMR-Bl 1 : 1 GHz to 40 GHz. 

With Opt. SMR-Bl 1 : 10 MHz to 40 GHz. 

Resolution - 

Without Opt. SMR-B3: 1 kHz. 

With Opt. SMR-B3: 0.1 Hz. 

REFERENCE FREQUENCY 
Aging (After 30 Days of Operation) - 

Standard: lxl0"®/year. 

Opt. SMR-Bl: <lxl0-Vday. 

Temperature Effect (0 to SS’C) - 

Standard: 2x10"*. 

Opt. SMR-Bl: <+>-8. 

Warm-up Time - 15 min (Opt. SMR-Bl). 

SPECTRAL PURITY 

Spurious Signals - 

Harmonics (level <+6 dBm)*': 
f ^0 GHz: <-55 dBc. 
f >20 GHz: <-40 dBc. 

Subharmonics: 
f < 20 GHz: <-65 dBc. 
f >20 GHz: <-30 dBc. 

Nonharmonics (50 kHz from carrier): 
f<l GHz: <-60 dBc. 

1 GHz ... 2 GHz: <-50 dBc. 

>2 GHz ... 10 GHz: <-60 dBc. 

>10 GHz ... 20 GHz: <-54 dBc. 
f >20 GHz: <-48 dBc. 

SSB Phase Noise (f = 10 GHz, 10 kHz from 
Carrier, 1 Hz Bandwidth, CW, FM Off) - 

<-83 dBc. 

Residual FM, rms (f = 10 GHz, FM Off) - 

0.3 kHz to 3 kHz: <-20 Hz. 

0.03 kHz to 20 kHz: <-200 Hz. 

Specifications for harmonics above 20 GHz 
(SMR20), 27 GHz (SMR27) and 40 GHz 
(SMH40) only typical. <h+3 dBm with Opt. 
SMR-B23/SMR-B24. 

LINEAR AMPLITUDE MODULATION 
WITH OPTION SMR-B5 
Operating Modes - Internal, external AC/DC. 
Modulation Depth*' - 0% to 100%. 
Resolution - 0.1%. 

Setting Error (AF = I kHz, m <80%) - <4% 

of reading +1%. 

Modulation Frequency Range - DC to 

100 kHz. 

Modulation Frequency Response (20 Hz to 
20 kHz, m = 60%) - <1 dB. 



Maximum Level Without Opt. SMR-B23/-B24 - 



Frequency Range 


SMR20 wtthout 
Opt. SMR-BIS 


SMRZO wHh 
Opt. SMR-B15 


SMR27/SMR40 
without Opt. SMR 
-B15/-B17 


SMR27/SMR40 
with Opt. SMR 
-B15/-B17 


0.01 to <1 GHz 


>+13 dBm 


>+13 dBm 


>+12 dBm 


>+12 dBm 


1 to <18 GHz 


>+11 dBm 


>+10 dBm 


>+8 dBm 


>+7 dBm 


18 to 20 GHz 


>+10 dBm 


>+8 dBm 


>+7 dBm 


>+5 dBm 


>20 to 27 GHz 


>+11 dBm 


>+9 dBm 






>27 to 40 GHz 


>+9 dBm 


>+7 dBm 







LOGARITHMIC AMPLITUDE MODULA- 
TION WITH OPTION SMR-B5 (SCAN AM) 
Operating Modes - Internal, external. 
Dynamic Range - >30 dB. 

Sensitivity - -0.1 dB/V to -10 dB/V. 
Resolution - 0.01 dB. 

Rise/Fall Time (10/90%) - <10 \\s. 

EXT2 Modulation Input - 
Input impedance: 600 Q. or 100 kQ. 

Input voltage range: -6 V to +6 V. 

FREQUENCY MODULATION WITH 
OPTION SMR-B5 

Operating Modes - Internal, external AC/DC. 

1 GHz to 2 GHz (N = -1):5MHz. 

>2 GHz to 10 GHz (N = 0): 10 MHz. 

>10 GHz to 20 GHz (N = 1): 20 MHz. 
f>20 GHz (N = 2):40 MHz. 

Resolution - <1%, min. 10 Hz. 

Setting Error (AF = 1 kHz) - <5% of reading 
+20 Hz. 

The maximum level is reduced by up to 2 dB 
in the temperature range 35 to 55°C. 

PULSE MODULATION 

Operating Modes - external, internal with 

option SMR-B14. 

On/Off Ratio - >80 dB. 

Rise/Fail Time (10/901b) - 
62.5 MHz to 125 MHz: <50 ns. 

>125 MHz to 450 MHz: <20 ns. 

>450 MHz: <12 ns. 

Puise Repetition Frequency - 
62.5 MHz to 125 MHz: <0 to 1 MHz. 

>125 MHz to 450 MHz: <0 to 2 MHz. 

>450 MHz: <0 to 10 MHz. 

Minimum Puise Width - 20 ns. 

Puise Delay - typ. 50 ns. 

Video Feedthrough - Upp<20 mV. 

PULSE Modulation Input - 
Input level: TTL/HCT signal. 

Input impedance: 50 L2 or 10 kO. 



SIMULTANEOUS MODULATION 

FM (FSK) is independent of AM (SCAN AM, 
ASK) and pulse modulation. 

Reduced AM bandwidth for simultaneous AM 
(SCAN AM, ASK) and pulse modulation. 

IF INPUT OPTION SMR-B23/-B24 

SMR-B24 SMR-B21 



Frequency range 


DC to 700 MHz 


Level 


<0 dBm 


SWR 


>2 


RF-Output 


Frequency range 


1 to 20GHz 2 to 27/40 GHz 


Level*’ 


<-10dBm 


SWR 


<2 



The RF output level can be lowered from 0 
dB to 110 dB in steps of 10 dB with Opt. 
SMR-Bl 5 /-B17. 



LF GENERATOR WITH OPTION SMR-B5 
Frequency Range - 0.1 Hz to 10 MHz. 
Resolution - 0.1 Hz. 

Waveforms - sinewave, squarewave. 
Frequency Error - <1<10“^. 

Frequency Response (Up to 500 kHz) - 
<0.5 dB. 

Distortion (Up to 100 kHz) - <0.5% (R|oad 
>200 ^2, level = 0.5 V). 



238 SIGNAL GENERATORS 



www.tektronix.com/Measurement/coraintest/ 





New Microwave Signal Generator SMR 

HIGH-PERFORMANCE, COST-EFFECTIVE AND RELIABLE UP TO 40 GHZ 



PULSE GENERATOR OPTION SMR-B14 

Operating Modes - automatic, external trig- 
ger, external gate mode, single pulse, double 
pulse, delayed pulse (externally triggered). 
Active Trigger - edge positive or negative. 
Pulse Repetition Period - 100 ns to 85 s. 
Resolution: 5 digits, min. 20 ns. 

Accuracy: same as reference frequency. 

Pulse Width - 20 ns to 1 s. 

Resolution: 4 digits, min. 20 ns. 

Accuracy: 5% of reading ±5 ns. 

Pulse Delay - 40 ns to 1 s. 

Resolution: 4 digits, min. 20 ns. 

Accuracy: 5% of reading -10 to +20 ns. 
Double Pulse - 60 ns to 1 s. 

Resolution: 4 digits, min. 20 ns. 

Accuracy: 5% of reading -10 to +20 ns. 
Trigger Delay Typ. - 50 ns. 

PULSE Modulation Input - 
Input level: TTL/HQ signal. 

Input Impedance: 50 Q or 10 kQ. 

SYNC Output - TTL/HCT signal, 40 ns pulse 
width. 

VIDEO Output - m/HQ signal. 



RAMP SWEEP OPTION SMR-B4 

RF Sweep, AF Sweep - 

Operating modes: 

automatic, single-shot, manual or externally 
triggered. 

start/stop, center freq./span, markers. 

Sweep range: freely selectable. 

Resolution: gt 1 kHz. 

Accuracy: (0.001% of deviation)/(sweep time/s) 
± reference error, min. 75 kHz ± reference error. 

Level Sweep - 

Operating modes: automatic, single-shot, man- 
ual or externally triggered, logarithmic. 

Sweep range: 0 dB to 20 dB. 

Resolution: >0.01 dB. 

Sweep time: 10 ms to 100 s (switchover time 
£30 ms at 1 GHz, 2 GHz, 10 GHz and 20 GHz). 
Max. sweep rate: 600 MHz/ms. 

Markers: 10, freely selectable. 

MARKER output signal: TTL level (HCT), 
selectable polarity. 

X output: 0 to 10 V. 

BLANK output signal: TTL level (HCT), selec- 
table polarity. 



MEMORY FOR INSTRUMENT SETUPS 
Storable Setups - 50. 

Memory Sequence Modes - automatic, sin- 
gle-shot, manual or externally triggered. 

Step Time - 50 ms to 60 s. 

Resolution - 1 ms. 

REMOTE CONTROL 
System - lEC 625 (IEEE 488). 

Command Set - SCP1 1995.0. 

Connector - 24-contact Amphenol. 
lEC/IEEE-bus Address - 0 to 30. 

Interface Functions - SHI, AHl, T6, L4, SRI, 
RLl, PPl, DCl, DTI, CO. 

Physical Characteristics 

Dimensions mm in. 



Width 


426.7 


16.8 




Height 


87.6 


3.4 




Depth 


450 


17.7 




Weight 


ks 


lb. 




When fully equipped 


<12 


<26.5 





Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the hack of this catalog. 



SIGNAL GENERATOR SMR20 

Includes: power cable, operating manual, female 

adapter 3.5 mm. 

Order 1104.0002.20. 

SIGNAL GENERATOR SMR27 

Includes: power cable, operating manual, female 

adapter 3.5 mm. 

Order 1104.0002.27. 

SIGNAL GENERATOR SMR40 

Includes: power cable, operating manual, female 

adapter 2.9 mm. 

Order: 1104.0002.40. 

OPTIONS 

SMR-B1 - OCXO Reference Oscillator. 

Order 1104.5485.02. 

SMR-B3 - Frequency Resolution 0.1 Hz. 

Order 1104.5585.02. 

SMR-B4 - Ramp Sweep. Order 1104.5685.02. 



SMR-B5 - AM/FM/SCAN Modulator. 

Order 1104.3501.02. 

SMR-B11 - Frequency Extension 0.01 GHz to 
1 GHz*'. Order 1104.4250.02. 

SMR-B14 - Pulse Generator. Order 1104.3982.02. 
SMR-B15 - RF Attenuator 20 GHz 
(SMR20/SMR27)*'. Order 1104.4989.02. 

SMR-B17 - RF Attenuator 40 GHz (SMR40)*'. 
Order 1104.5233.02. 

SMR-B19 - Rear Connectors for RF, AF 
(SMR20/SMR27)*'. Order 1104.6281.02. 

SMR-B20 - Rear Connectors for RF, AF (SMR40)*'. 
Order 1104.6381.02. 

SMR-B23 - IF Input 20 GHz (SMR20)*'. 

Order 1104.5804.02. 

SMR-B24 IF Input 40 GHz (SMR27/SMR40)*'. 
Order 1104.6100.02. 

RECOMMENDED EXTRAS 

SMR-Zl - Service kit. Order 1103.9506.02. 

ZZA-211 - 19 in. rack adapter. Order 1096.3260.00. 



ADAPTER (SMR20/SMR27) 

3.5 mm female - Order 1021.0512.00. 

3.5 mm male - Order 1021.0529.00. 

N female - Order 1021.0535.00. 

N male - Order 1021.0541.00. 

ADAPTER (SMR40) 

2.9 mm female - Order 1036.4790.00. 

2.9 mm male - Order 1036.4802.00. 

N female - Order 1036.4777.00. 

N male - Order 1036.4783.00. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916. inside the U.S. call: 1-800-426-2200. 

Product(s) available through your local Tektronix 
Distributor listed in the back of this catalog. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



www.tektronix.com/Measurement/commtest/ 



SIGNAL GENE RATO R S 239 






Features - Benefits Applications 



Frequency Range 2 to 40 GHz 
(SMP04), 2 to 26.5 GHz (5MP03), 
10 MHz to 20 GHz (SMP02, SMP22 
Opt. 1 1), 2 to 20 GHz (SMP02, 
SMP22) 

Maximum Output Level +8 dBm 
(SMP04), +12 dBm (SMP03), 

+11.5 dBm (SMP02), +20 dBm 
(SMP22) 

Ultra-low RF Leakage 
Nonvolatile Storage for up to 50 
Complete Instrument Setups 



Radar and Communications 
Receiver Testing 
Research and Development 
EMI Testing 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call; 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 



Product(s) complies with 
IEEE Standard 488.2-1987, 
with SCPl compliance. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



SMP Signal Generator 

The SMP Signal Generator is a high-frequency 
microwave signal source providing high output 
power with accurate level setting, high spectral 
purity, and excellent pulse modulation. 



Characteristics 



FREQUENCY 
Range - See chart. 

Resolution - 0.1 Hz. 

Accuracy @ 1 CHi - 1000 Hz based on reference aging 
rate per year. 

Stability - ±1 x 10‘Vyear, ±1 x lO’Vday, with Opt. 01. 
Setting Time - <11 ms +10 ms/CHz after IEEE bus 
delimiter. 

OUTPUT LEVEL 
Range - See chart. 

Resoiution - 0.1 dB. 

Accuracy - +0.6 to +1.5 dB level dependent. 



MODULATION 
AM Rate - DC to 100 kHz. 

AM Depth - 0 to 90<Vo. 

FM Rate - DC to 1 MHz. 

FM Max Deviation - SMP02, SMP22: 10 MHz. SMP03, 
SMP04: 20 MHz (2 MHz with Opt. 5). 

Phase Modulation - Yes with Opt. 02 and 05. 

Phase Rate - 0.4/1/3/15 kHz internal, DC to 100 kHz 
external. 

Phase Deviation (maximum) - 10 radians. 

Pulse Modulation - Yes, optional. Pulse width: 20 ns 
to 1 s. 

Pulse rate: 100 ns to 85 s, 0 to 10 MHz. 

Pulse delay: 20 ns to 1 s. 

On/Off Ratio - >80 dB. 

Rise/Fall Time - <10 ns. 

Simultaneous Modulation - Yes. 

Internal Modulation Generator - 0.4/1/3/15 kHz. 
Digital Modulation - Yes, external. 

FSK Modulation - Yes, external. 

SWEEP 

Functions - Digital, in discrete steps, linear or log. 
Modes - Automatic, manual, single-shot and external 
triggered. 

Start/Stop - Yes. 

Center Frequency/Delta Frequency - Yes. 

Markers - 3. 



240 SIGNAL generators 



www.lektronix.com/Measurement/coninite$t/ 





Signal Generators 

SMP 



OTHER FEATURES 
IEEE-488 Interface - Yes. 

POWER REQUIREMENTS 

Line Voltage - 90 to 132 V, 180 to 265 V. 

Line Frequency - 47 to 440 Hz. 



ENVIRONMENTAL- 
Operating Temperature - SMP02, SMP03, 
SMP04: 0 to 50°C. SMP22: 0 to 50°C. 
Mechanicai Stress - MIL-STD 810 D. 
Electromagnetic Compatibiiity - MIL-STD 
461 B, RE02, CE03, CSOI, CS02. 



Physical Characteristics 

Dimensions mm in. 



Height 


192 


7.89 


Width 


435 


17.8 


Depth 


570 


23.42 


Vlteight 


■« 


lbs. 


Net 


27 


59.4 



SMPOZ SMP03 SMP04 SMP2Z 



FREQUENCY 


Range 


2 to 20 GHz 


2 to 27 GHz 


2 to 40 GHz 


2 to 20 GHz 




(10 MHz to 20 


(10 MHz to 27 GHz 


(10 MHz to 40 GHz 


(10 MHz to 20 GHz 




GHz with Opt 11) 


with Opt n) 


with Opt 11) 


with Opt. 11) 


OUTPUT LEVEL 


Range 


-20 to +11.5 dBm 


-20 to +12 dBm 


-20 to +8 dBm 


-20 to +20 dBm 




to -130 dBm 


to -130 dBm 


to -130 dBm 


to -130 dBm 




with Opt 15 


with Opt 15 


with Opt 15 


with Opt 15 


SPECTRAL PURITY 


Harmonics 


<-30 dB, -50 dBc typical 


<-40 dBc, f>20 GHz 


<-30 dBc, f>20 GHz 


<-25 dBc 




above 1.8 GHz 








Subharmonics 


None f<20 GHz 


<-40 dBc f>20 GHz 


<h|0 dBc f>20 GHz 


None f>20 GHz 


Nonharmonics 


<-60 dBcf<20 GHz 


<-50 dBc f<2 GHz 


<-50 dBc f<2 GHz 


<-60 dBcf<20 GHz 


at >10 kHz from carrier 




<-60 dBc f>2<20 GHz 


<-60 dBc f>2<20 GHz 








<-54 dBc f>20 GHz 


<-54 dBc f<20 GHz 




Residual FM 










10 MHz to 10 GHz 


<5 Hz 


<5 Hz 


<5 Hz 


f<5Hz 


10 GHz to 20 GHz 


<10 Hz 


<10 Hz 


<10 Hz 


f<20 GHz 


20 GHz to 27/40 GHz 










SSB Phase Noise 










10 GHz, 10 kHz Offset 


<-98 dBc 


<-98 dBc 


<-98 dBc 


<-98 dBc 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



SMP02 

20 GHz Signal Generator. 

SMP03 

26.5 GHz Signal Generator. 

SMP04 

40 GHz Signal Generator. 

SMP22 

20 GHz Signal Generator. 

Includes: Power Cable, Operating Manual, 3.5 mm 
Female Adapter (SMP02, SMP03, SMP22), 2.9 mm 
Female Adapter (SMP04). 

Opt. 01/SM-B1 - OCXO Reference Oscillator. 

Opt. 02/SM-B2 - LF Generator. 

Opt. 05/SM-B5 - FM/phiM Modulator. 

Opt. 11/SMP-B11 - 
Frequency Extension, 0.01 to 2 GHz. 



Opt. 12/SMP-B12 - Pulse Modulator, 2 to 40 GHz. 
Opt. 13/SMP-B13 - Pulse Modulator, 0.01 to 2.0 GHz. 
Opt. 14/SIVIP-B14 - Pulse Generator. 

Opt. 15/SMP-B15 - RF Attenuator, 20 GHz. 
Opt.17/SMP-B17 - RF Attenuator, 40 GHz. 

Opt. 18/SMP-B18 - Auxiliary Interface. 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of Calibration Services. 

Opt. D1 - Cal Data Report. 

Opt. D3 - Test Data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover 
three years. 

Additional Accessories - Also see page 495. 



For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, Inside the U.S. call: 1-800-426-2200. 




Product(s) complies with IEEE Standard 488.2-1987, 
with SCPI compliance. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



www.tektronix.com/Measurement/commtest/ 



SIGNAL GENERATORS 241 




Signal Generators 

SMT 




Features - Benefits Applications 



Frequency Range 5 kHz to 6 GHz 
(SMT06), 5 kHz to 3 GHz (SMT03), 
5 kHz to 1.5 GHz (SMT02) 

Broadband FM Modulation from 
DC to 8 MHz with Deviation Up to 
20 MHz 

Amplitude Modulation 

Phase Modulation OM) from DC to 
2 MHz 



Radar Applications (with SMT06 
Opt. 09, SMT03 Opt. 08, SMT02 
Opt. 03) 

VOR/ILS Receiver Tests (with Opt. 
06) 

FM Broadcast Transmitter and 
Receiver Test and Design (with Opt. 
06) 



Convenient RF, LF, and Level 
Sweeps 

Optional LF Generator (Opt. 02) 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 




Product(s) complies with 
IEEE Standard 488.2-1987, 
with SCPI compliance. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



SMT Signal Generator 

The SMT Signal Generator covers the complete 
range of conventional analog receiver measure- 
ments up to 6 GHz. It provides exceptionally 
high signal quality, outstanding level of accura- 
cy, a wide variety of modulation and signal gen- 
eration modes, a customizable configuration and 
ease of operation. 



THE IDEAL EMS SIGNAL SOURCE 

With a specified lower frequency limit of 5 kHz 
(under-range down to 1 kHz), the SMT fully cov- 
ers the frequency range for EMS measurements 
stipulated by lEC 801. The digital, step-by-step 
sweep function, with preselectable start and stop 
frequency, span, step width and step time, 
enables the convenient testing of wide frequency 
ranges. During tlie frequency sweeps, no level 
overshoots will occur. The sweep function can 
also be used for the RF level and AF fi:equency. 

The frequency response of cables, amplifiers, 
TEM cells, etc., can be compensated in the sig- 
nal generator by means of a level-correction 
function. Complicated external level controls or 
test routines are not required. 



242 



SIGNAL GENERATORS 



www.tektronix.com/Measurement/commtest/ 







Signal Generators 

SMT 



EXCELLENT RF CHARACTERISTICS AT A 
REASONABLE PRICE 

For high-frequency measurements on 
AM, FM and SSB receivers, the signal 
source must he superior to the device- 
under-test. The low residual FM and 
SSB phase noise of the SMT make it 
suitable for in-channel and blocking 
measurements, even on high-end 
receivers. The small level error of <1 dB 
throughout the frequency range allows 
high-precision sensitivity measurements. 



MINIMUM RF EMISSIONS FOR 
SENSITIVE DUTS 

Measurements on highly sensitive 
receivers such as pagers not only 
require high signal quality, but also 
extremely high RF shielding of the 
signal source. Elaborate shielding 
measures keep RF emissions of the 
SMT to a minimum. 



MEMORY SEQUENCE FUNCTION FOR 
AUTOMATIC MEASUREMENTS 

For frequently repeated measurement 
series, the memory sequence function 
allows a sequence of measurements to 
be run without an external controller. 
Up to 50 instrument settings can be 
stored in non-volatile memory. 



Characteristics 



See page 226 for characteristics. 



Ordering Information 



For price information: Outside the U.S. contact 

SMT06 

Signal Generator (5 kHz to 6 GHz). 

Includes: Power Cord, Operating Manual. 

SMT03 

Signal Generator (5 kHz to 3 GHz). 

Includes: Power Cord, Operating Manual. 

SMT02 

Signal Generator (5 kHz to 1.5 GHz). 

Includes: Power Cord, Operating Manual. 

Opt. 01/SM-B1 - OCXO Reference Oscillator. 

Opt. 02/SM-B2 - LF Generator. 

Opt. 03/SM-B3 - (SMT02) Pulse Modulator. 

Opt. 04/SM-B4 - Pulse Generator. 

Opt. 06/SM-B6 - Multifunction Generator. 

Opt. 08/SM-B8 - (SMT03) Pulse Modulator. 

Opt. 09/SM-B9 - (SMT06) Pulse Modulator. 

Opt. 20/SMT-B19 - Rear-panel Connectors for 
RF and AF. 



your local Tektronix representative, inside the U.S. 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of Calibration Services. 

Opt. D1 - Cal Data Report. 

Opt. 03 - Test Data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover 
three years. 

ADDITIONAL ACCESSORIES 

Also see page 495. 



the price list in the back of this catalog. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 




Product(s) complies with IEEE Standard 488.2-1987, 
with SCPI compliance. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



see 



www.tektronix.com/Measurement/commtest/ 



SIGNAL GENERATORS 243 







Signal Generators 

SME 




For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 




Product(s) complies with 
IEEE Standard 488.2-1987, 
with SCPI compliance. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



Features - Benefits Applications 



Frequency Range 
-5 kHz to 6 GHz SME06 
-5 kHz to 3 GHz SME03 
-5 kHz to 1.5 GHz SME02 

All Common Digital Modulation 
Modes Provided in One Unit: 

GMSK, ti/4-DQPSK, GFSK, FSK, 

4FSK, FFSK, ... 

No External Modulation or Data 
Sources Required 

Internal Control of Frequency and 
Level Hopping Synchronous with 
the Data Signal 

Freely Programmable Data 
Sequences and Trigger Conditions 

Frequency Setting Time <0.5 ms for 
Frequency-agile Systems (Not 
Available in SME03E) 

Extremely High Spectral Purity for 
Out-of-channel Measurements 

Very High Level Accuracy; Resetting 
Error of Attenuator 0.01 dB 

RF, AF and Level Sweep 

Programmable Measurement 
Sequence for up to 50 Complete 
Instrument Settings 



Digital Radio Receivers 
Digital Radio Networks 
Analog Modulations 



SME SIGNAL GENERATOR 

The SME Signal Generator supplies the complex 
signals required for the development and testing 
of digital mobile radio receivers. It’s capable of 
generating all signals used in the main TDMA 
radio networks in line with relevant standards 
regarding the type of modulation, data format, 
TDMA structure and frequency hop patterns. 
The SME is also useful in the analog signal 
world of conventional signal generators. 



The SME covers a frequency range from 5 kHz 
to 6 GHz. They can be tailored to your require- 
ments by means of a wide variety of options 
with emphasis either on digital modulation, 
analog applications or expansion into a uni- 
versal signal generator. 



244 



SIGNAL GENERATORS 



www.tektronix.com/Measurement/commtest/ 





Signal Generators 

SME 



DIGITAL MODULATION 

With the DM Coder (standard on 
SME03E, Opt. 11 all other models) the 
SME provides a variety of network-spe- 
cific digital modulation modes: 



Modulation 


Network 


GMSK 


GSM, DCS 1800/DCS 1900 
(PCN), CDPD, DSRR, 
MC9,M0BILTEX 


pi/4-DQPSK 


NADC, PDC, TFTS, 
TETRA, APC025 


GFSK 


DEa,a2,a3 


4FSK 


ERMES, APC025 
FLEX, MODACOM 


FSK,FFSK 


POCSAG, FLEX, Cityraf 



The SME has been designed to allow 
for the integration of future types of 
modulation and networks. 



Frequency and phase changes are pro- 
duced by DDS (direct digital synthe- 
sis). The frequency and phase response 
are therefore synthesizer-accurate. 
There is no drift at the carrier frequen- 
cy. The DM coder is provided standard 
in the SME03E. 

The modulation spectrum stands out 
for its high spectral purity. Sidebands 
are well below permissible levels at the 
frequency spacing relevant for adjacent- 
channel measurements. Filters other 
than the standard ones may be used for 
varying the modulation spectrum (for 
CMS network: filters with BxT = 0.2, 

0.3, 0.5). With GFSK modulation for 
DECT, non-standard deviations may be 
set to allow in-depth receiver tests. 



The data signals for modulation are 
applied externally or supplied by the 
internal data generator. Bit rates are 
selectable with FSK; they are network- 
specific for other types of modulation. 



Characteristics 



See page 226 for characteristics. 



your local Tektronix representative, inside the U.S. see 



Ordering Information 



For price information: Outside the U.S. contact 

SME06 

Signal Generator (5 kHz to 6 GHz). 

SME03 

Signal Generator (5 kHz to 3 GHz). 

SME02 

Signal Generator (5 kHz to 1.5 GHz). 

Opt. 01/SM-B1 - Reference Oscillator oao. 

Opt. 02/SM-B2 - LF Generator. 

Opt. 03/SM-B3 (SME02) - Pulse Modulator. 

Opt. 04/SM-B4 (Opt. 03, Opt. 08 or Opt. 09 
required) - Pulse Generator. 

Opt. 05/SM-B5 - FM/phiM Modulator. 

Opt. 06/SM-B6 - Multifunction Generator. 

Opt. 08/SM-B8 (SME03) - 
Pulse Modulator. 

Opt. 09/SM-B9 (SME06) - Pulse Modulator. 

Opt. 11/SME-B11 - DM Coder. 



www.tektronix.com/Measurement/comintest/ 



Opt. 12/SME-B12 - DM Memory Expansion. 

Opt. 19/SME-B19 - Rear Connectors for RF and AF. 
Opt. 41/SM-B41 - Flex Protocol. 

Opt. 42/SM-B42 - POCSAG Protocol. 

Opt. B50/SME-B50 - High Speed CPU. 

RECOMMENDED ACCESSORIES 

Also see page 495. 

19 in. Rack Adapter - Order ZZA-94. 

Service Kit - Order SMZ2. 

MEASUREMENT SERVICE OPTIONS 

SME02/03/03E/SME06 

Opt. C3 - Three years of Calibration Services. 

Opt. D1 - Cal Data Report. 

Opt. D3 - Test Data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover 
three years. 



the price list in the back of this catalog. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 




Product(s) complies with IEEE Standard 488.2-1987, 
with SCPI compliance. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



SIGNAL GENERATORS 245 






EMI/RFI Solutions 



Contents 

EMI Test Receivers: 

ESI 247 

ESCS30 250 

ESHS, ESVS, ESS 252 

EMI/Radio Monitoring Solutions: 

ESVB, ESVD, ESVN, ESN 255 

EMI Software: 

ES-Kl 259 

EMI Precertification Receiver: 

ESPC 260 

EMI Measurement System: 

27120B 262 

Stepping RF Preselection: 

2706 264 

EMC Ancillary Devices 265 

Antennas, Transducers, and Related 
Devices for EMI Testing 265 



EMI/RFI Solutions - An Introduction 

Electrical and electronic devices may emit signals 'which interfere with other 
devices, or even with themselves. These signals are known as electromagnetic inter- 
ference (EMI) or sometimes as radio frequency interference (RFI). Conversely, the 
ability of a device to withstand emissions from other devices or from itself is called 
immunity. The inverse of immunity is electromagnetic susceptibility (EMS). 

As the number of electronic devices in use increases, so does the potential for these 
devices to interfere with each other. Electromagnetic compatibility (EMC) is a meas- 
ure of how well they share their electromagnetic environment without adverse 
affects from EMI. 

The goal of EMC is to construct electrical equipment with sufficiently low emis- 
sions and sufficiently high immunity to guarantee electromagnetic compatibility. 

The definition and enforcement of “sufficiently high” and “sufficiently low” 
becomes a matter of standards and regulations. In fact, when we refer to EMC com- 
pliance, we generally mean the ability of a system or device to meet standards regu- 
lating the amount of EMI that it can emit and its immunity to EMI. 

EMC/EMI is a vital concern to manufacturers of electrical equipment subject to 
compliance. Their products must meet the applicable standards before they can be 
marketed. To ensure electromagnetic compatibility, the necessary measures should, 
therefore, be considered as early in the design phase as possible so they can be 
implemented in product development. 

EMI 

Electromagnetic interference or emissions from an electrical or electronic device 
may significantly impair radio and TV reception in the vicinity. While this is clear- 
ly an annoyance, an even greater concern is interference to navigation and commu- 
nications equipment on board aircraft. 

To prevent such a critical situation and to allow a wide variety of devices to operate 
next to and with each other, it’s important to define interference limits ensuring a 
sufficient safety margin between EMI emissions and EMS limit values. Depending 
upon the standard being applied and the limit class required, different test condi- 
tions have to be observed in interference measurements. Test measurements are 
made either in shielded rooms or at an open-area test site as required. It is impor- 
tant that the measuring instruments themselves should not influence the result. 

EMS 

EMS measurements are made to test the function of a module, instrument, or sys- 
tem under the influence of conducted or radiated interference. These measurements 
must be carried out in shielded rooms or anechoic chambers. RF absorbers in the 
test chamber prevent erroneous results and simulate open-site conditions at high 
frequencies. 

FIELD- STRENGTH AND RADIO MONITORING MEASUREMENTS 

Radiocommunications services (PTT, broadcasting corporations, military, traffic and 
security authorities, as well as civil services) use field-strength meters for propaga- 
tion measurements in the planning stage and for coverage measurements during 
operation of communication networks. 

Field-strength measurements - in particular, propagation and coverage measiue- 
ments - are usually made in mobile mode (vehicle or aircraft). Therefore, portabili- 
ty and DC or battery operation are important criteria in the choice of a test receiver. 

Radio monitoring services use test receivers to check emissions for compliance with 
the specifications. Test parameters include field-strength, wave propagation, spuri- 
ous responses, frequency, occupied bandwidth, frequency deviation, and amplitude 
modulation depth, as well as channel and band occupancy. 



EMI/RFI SOLUTIONS 



www.tektronix.com/Measurement/commtest/ 



246 



Applications 



EMI Test Receivers 



New ESI 




Features - Benefits 



Frequency Range 
-ESI7: 20 Hz -7 GHz 
-ESI26: 20 Hz - 26.5 GHz 
-ESI40: 20 Hz - 40 GHz 

State-of-the-art Technology 
-Low Inherent Noise 
-Wide Dynamic Range 
-Preselection and 
Preamplification 
-Automatic Overload Control 
-Pulse-protected 2nd RF Input 
-Fast Overview Measurements 

Current Standards 
-Correct Weighting of Pulses to 
CISPR 16-1 and VDE 0876 
-All Commercial and Military 
Standards Like CISPR, EN, ETS, 
FCC, VDE, ANSI, VCCI, MIL-STD, 
VG, DEF-STAN, and Many Others 

Straightforward Operation 
-Active Color LCD 
-Analog Level Display for Each 
Detector (Parallel Operation) 
-Split-screen Display for Detailed 
Analysis 



Industrial and Military EMI Testing 

Verifying Transmitter (BTS) 
Performance 

Digital Modulation Analysis 
EMC Diagnostic Work 
EMC Final Certification 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call; 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 



C€ 



Final-certification EMI 
Measurements up to 40 GHz 

The ESI family of EMI test receivers combines 
the flexibility and speed of spectrum analyzers 
with the large dynamic range required for EMI 
measurements in conformance with standards. 



ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



The ESI family comprises three models with dif- 
ferent upper frequency limits: 

► ESI7: 20 Hz to 7 GHz 

► ESI26: 20 Hz to 26.5 GHz 

► ESI40: 20 Hz to 40 GHz 

All three models are characterized by: 

► High sensitivity 

► Excellent large-signal immunity 

► Low measurement uncertainty 

► High measurement speed 



MEASUREMENTS TO STANDARD 

ESI carries out measurements in conformance with 
all industrial and military EMI standards such as 
CISPR, EN, VDE, ANSI, FCC, BS, ETS, VCCI, MIL- 
STD, VG, DEF-STAN, DO160 and GAM EG13. The 
ESI family complies with the basic standard, i.e. 
CISPR16-1 or VDE0876, which places stringent 
requirements on receiver d}mamic range. 

TEST ROUTINES ORIENTED TO PRAaiCAL 
REQUIREMENTS 

During the various development phases of a 
product, different measurements are performed 
as required for each stage. The ESI family offers 
appropriate featrues and routines for the differ- 
ent development stages. 



www.tektronix.com/Measurement/commtest/ 



EMI/RFI solutions 247 






EMI Test Receivers 

NEW ESI 



The ESI is outstanding for its low inher- 
ent noise, high intermodulation sup- 
pression and low SSB phase noise. 
Modulation analysis of analog or digital 
signals is possible with the optional 
Vector Signal Analyzer FSE-B7. 
Moreover, ESI provides all test routines 
offered hy modern spectrum analyzers, 
such as noise measurement, phase 
noise measurement, channel and adja- 
cent-channel power measurement and 
time-domain measurement, as known 
from the FSE family. 

DEFINITION OF STANDARD TEST 
SEQUENCES 

To meet the requirements of relevant 
standards, measurements over various 
frequency ranges and bandwidtlis have 
to be performed, using different step 
sizes and measurement times or different 
receiver settings characteristics. For this 
purpose, ESI offers a user-configurable 
scan table with up to 10 subranges. 

EMI emissions are usually measured in 
two steps. An overview measurement 
made with the peak detector identifies 
critical emissions above or close to 
limit values. In a second measurement 
with the prescribed detectors (quasi- 
peak and average, in compliance with 
CISPR) and an appropriate measure- 
ment time, the critical frequencies are 
checked for compliance with limit val- 
ues. The ESI family supports this proce- 
dure by two independent measurement 
windows on the screen. 

SPLIT-SCREEN DISPLAY 

Critical emissions can be measured 
with numerical display of frequency 
and level as with classic receivers. Bar 
graphs provide an analog display of 
measured values for the various detec- 
tors simultaneously and in different 
colors. By coupling the marker in the 
overview spectrum to the receiver fre- 
quency, emissions can be measured fast 
and reliably in line with standards. In 
the second window, the operator can 
zoom in on the displayed trace. 

ESI can store up to 70,000 measured val- 
ues per trace in background operation. 
This considerably reduces measurement 
time, since no new measurement is need- 
ed to make a detailed analysis. 



LISTEN, VIEW, MEASURE 

To analyze the spectrum and to exclude 
ambient noise, tune the receiver fre- 
quency to the marker frequency, and 
activate the built-in AM/FM demodula- 
tor by switching on the loudspeaker or 
headphones. 

DOCUMENTATION OF RESULTS 

Practically any type of printer can be 
used for the documentation of results. 
ESI runs under Windows NT, so all 
printers for which Windows drivers are 
available can be employed. 

Results can not only be output to a 
printer but also stored on a floppy disk 
or the internal hard disk in common 
Windows formats like EMF, WMF or 
BMP. The data can be integrated into 
commercial word processing programs 
for the generation of test reports. 

HIGH ACCURACY 

In the frequency range up to 1 GHz, ESI 
performs level measurements with an 
accuracy of ± 1 dB, clearly better than 
the value of 2 dB specified by CISPR16-1. 

SYSTEM INTEGRATION 

The fast data processing of ESI makes it 
an ideal choice for use in automatic 
measurement systems. The IEEE 488-2- 
bus command set (lEC 625-2) conforms 
to SCPI (1994.0). 

With a the IEEE 488-bus card (Opt. 
FSE-B17), the ESI can be used as a test 
system controller. This is possible 
because, with the operating system 
Windows NT, an integrated controller 
function is provided as standard which 
allows the use of a wide variety of 
Rohde&Schwarz software packages. 

This enables the implementation of 
complete measurement systems without 
the need for an additional controller, 
which saves space and cost. 



Characteristics 



FREQUENCY 

Frequency range: Input 1 - 

ESI 7 : 20 Hz to 7 GHz. 

ESI 26 : 20 Hz to 26.5 GHz. 

ESI 40 : 20 Hz to 40 GHz. 

Input 2 - 20 Hz to 1 GHz. 

Frequency resolution - 0.01 Hz. 
Aging per year*' - 2.5 x 10 "^. 



FREQUENCY DISPLAY (RECEIVER 
MODE) 

Display - Numerical display. 

Resolution - 0.1 Hz. 

FREQUENCY DISPLAY (ANALYZER 
MODE) 

Display - With marker. 

Resolution - 0.1 Hz to 10 kHz (depending on 
span). 

Frequency counter - Measures the marker 
frequency. 

Resolution - 0.1 Hz to 10 kHz, selectable. 

FREQUENCY SCAN (RECEIVER MODE) 
Scan - Scan with max. 10 subranges with dif- 
ferent settings. 

Measurement time per frequency - 100 ps 

to 1000 s, selectable. 

SWEEP (ANALYZER MODE) 

Span 0 Hz (zero span) - 1 ps to 16000 s, 
selectable steps of 5 %. 

Span - >10 Hz 5 ms to 1000 s, selectable in 
steps of <10%. 

Picture refresh rate/s - (span ^ GHz): > 20 
updates/s with 1 trace, > 15 updates/s with 2 
traces at shortest sweep time. 

Sampling rate - 50 ns (20 MHz A/D converter). 
Preamplifier (9 kHz to 7 GHz) - 
Selectable, between preselector and 1st mixer, 
gain 20 dB. 

IF BANDWIDTHS (RECEIVER MODE) 

6 dB bandwidths - 10 Hz, 100 Hz, 200 Hz, 1 
kHz , 9 kHz, 10 kHz, 100 kHz, 120 kHz, 1 MHz, 
10 MHz. 

RBW <1 MHz: < 10 %. 

RBW <1 kHz: < 5 o/o. 

RBW <1 kHz: <100/0. 

RESOLUTION BANDWIDTHS 
(ANALYZER MODE) 

3 dB bandwidths - 1 Hz to 10 MHz, in steps 
of 1 / 2 / 3 / 5 . 

RBW <3 MHz: <10o/o. 

RBW = 5 MHz: <150/0. 

RBW =10 MHz: + 25 o/o, - 10 o/o. 

Shape factor Bgo dB - B3 dB. 

RBW< 1 kHz: <6. 

RBW =1 kHz to 2 MHz: <12. 

RBW >2 MHz: < 7 . 

Video bandwidths - 1 Hz to 10 MHz, in steps 
of 1 / 2 / 3 / 5 . 

FFT filter - 

3 dB bandwidths: 1 Hz to 1 kHz, in steps of 
1 / 2 / 3 / 5 . 

Shape factor Bgo dB: B3 dB , nominal 2 . 5 . 



248 EMI/RFI SOLUTIONS 



www.tektronix.com/Measurenient/coinmtest/ 






EMI Test 

NEW ESI 



Receivers 



ES17 ES126 ESI40 

Max, dynamic range 1 Hz bandwidth 1 Hz bandwidth 1 Hz bandwidth 



1 dB compression point / displayed noise floor 


162 dB 


160 dB 


Max. intermodulation-free range 


150 MHz to 7 CHz/26.5 GHz (nominal) 


115 dB 


112 dB 


Intermodulation free range at 


105 dB 




-40 dBm mixer input level 







LEVEL 

Display range - Displayed noise floor to 
137 dBpV. 

Max. input level - 

Input 1 - ESI7: 20 Hz to 7 GHz. 

ESI26; 20 Hz to 26.5 GHz. 

ESI40: 20 Hz to 40 GHz. 

RF attenuation >10 dB: 

DC voltage: 0 V. 

Sinewave AC voltage: 137 dBpV (= 1 W). 

Max. pulse voltage: ESI7: 150 V, ESI26/40: 50 
V, ESI7: 1 mWs, ESI26/40: 0.5 mWs. 

Max. pulse energy (10 ps): ESI7: 150 V, 
ESI26/40: 50 V, ESI7: 1 mWs, ESI26/40: 

0.5 mWs. 

Input 2 (receiver mode) - 20 Hz to 1 GHz. 
RF attenuation >10 dB: 

Sinewave AC voltage: 137 dBpV (= 1 W). 

Max. pulse voltage: ESI7: 1500 M, ESI26/40: 
250 V. 

Max. pulse energy (10 ps): ESI7: 30 mWs, 
ESI26/40: 15 mWs. 

1 dB compression of input mixer (RF 
attenuation 0 dB) - 

Analyzer mode: +10 dBm nominal. 

Level display (receiver mode) - 

Digital: numerical, 0.1 dB resolution. 

Analog: bar graph display, separate for each 
detector. 

Spectrum: level axis 10 dB to 200 dB in steps of 
10 dB, frequency axis freely selectable, linear 
or logarithmic. 

Units of level display: dBpV, dBm, dBpA, 
dB(rho)W, dB(rho)T, dB(pV/m), dB(pA/m). 
Detectors: average (AV), RMS, peak (PK) and 
quasi-peak (QP), 4 detectors can be switched 
on simultaneously. 



Level display (analyzer mode) - 

Result display: 500 x 400 pixels (with one 
diagram displayed); max. 2 diagrams with 
Independent settings. 

Trace detectors: max. peak, min. peak, auto 
peak (normal), sample, rms, average. 

Trace functions: clear/write, max. hold, min. 
hold, average. 

AUDIO DEMODULATION 
Modulation modes - AM and FM. 

Audio output: loudspeaker and phone jack. 

TRIGGER FUNCTIONS 

Trigger - free-run, single, line, video, gated, 

delayed, external, RF. 

Display - 24 cm LC color display (9.5 in.). 
Resolution: 640 x 480 pixels (VGA resolution). 
Pixel error rate: <2 x 10"^. 

Mass memory - 1.44 Mbyte 3.5" disk drive, 
hard disk. 

Operating temperature range - 

Nominal temperature range: +5®C to +40®C. 
Limit temperature range: 0°C to +50°C. 

Storage temperature range: -40°C to +70°C. 
Environmental conditions: +40°C at 95% relative 
humidity (lEC 68-2-3). 



Power supply - 

AC supply: 200 V to 240 V: 50 Hz to 60 Hz, 100 
V to 120 V: 50 Hz to 400 Hz, class of protection 
I to VDE 411. 

Power consumption: 195 VA (ESI7) 230 VA 
(ESI26 & ESI40). 

Safety - CSAIOIO.I, EN61010-1. 



PHYSICAL CHARACTERISTICS 

Dimensions mm 



Height 


435 


width 


236 


Depth 


570 


Weight 


1(2 


ESI7 


25.1 


ESI26 


26.4 


ESI40 


27 



After 30 days of operation. 

Valid for span >100 kllz. 

For RF frequencies >7 GHz: error after calling 
peaking function. For sweep time <10 
ms/GHz: additional error .1.5 dB. 



Ordering Information 



your local Tektronix representative, inside the U.S. see 



For price information: Outside the U.S. contact 

ESI7 

EMI Test Receiver (20 Hz to 7 GHz). 

ESI26 

EMI Test Receiver (20 Hz to 26.5 GHz). 

ESI40 

EMI Test Receiver (20 Hz to 40 GHz). 

OPTIONS 

Opt. FSE-B3 - TV Demodulator. 

Opt. FSE-B7 - Vector Signal Analyzer. 

Opt. FSE-B10 - Tracking Generator 7 GHz. 

Opt. FSE-B11 - Tracking Generator 7 GHz with l/Q 
Modulator. 

Opt. FSE-B12 - Switchable Attenuator for Tracking 
Generator. 

Opt. FSE-B17 - Second lEC/IEEE-Bus Interface. 

Opt. BI602 - Ethernet Interface 15-Contact AUl 
Connector. 

Opt. BI603 - Ethernet Interface thin wire BNC 
Connector. 



SOFTWARE 
EMI Software for 

EMI Test Receiver (Windows) - Order ES-KI. 
Script Development Kit - Order ES-K2. 

Driver for ESI7/26/40 - Order ES-K16. 

Driver for Mast (HCM) and 
Turntable (HCTI2) - Order ES-K30. 

Driver for EMCO Mast/Tumtable - Order ES-K32. 
Driver for MDS Absorbing Clamp 
Slideway (HCA) - Order ES-K31. 

RECOMMENDED EXTRAS 
Service Kit - Order FSE-Zl. 

DC Block, 

5 MHz to 7000 MHz (type N) - Order FSE-Z3. 

DC Block, 10 kHz to 18 GHz (type N) - 

Order FSE-Z4. 

Microwave Measurement Cable and Adapter 

Set - Order FS-Z15. 



the price list in the back of this catalog. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

Product(s) available through your local Tektronix 
Distributor listed in the back of this catalog. 

C€ 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



www.tektronix.com/Measurement/commtest/ 



E M I / R F 



SOLUTIONS 249 




Applications 



EMI Test Receiver 

ESCS30 




Features - Benefits 



Frequency range: 9 kHz to 2.75 GHz Commercial EMI Testing 

High Measurement Accuracy: Error 
<1 dB;typ. <0.5 dB 

Fast Synthesizer: Any Frequency 
Step in <1 ms; Frequency 
Resolution Down to 10/100 Hz 
(Internal <1 Hz) 

CISPR Filters: 200 Hz, 9 kHz, 

120 kHz with Constant Group Delay 

Parallel Detectors for Peak, Quasi- 
peak and Average Indication; All 
Detectors can be Switched on 
Simultaneously 

Tracking Generator for Attenuation 
and Gain Measurements; e.g., for 
Checking Test Cables (9 kHz to 
2750 MHz; Opt. ESCS-B5) 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



Compact EMI Test Receiver Compliant 
TO All Commercial Standards 

The EMI Test Receiver ESCS30, fully complying 
with the CISPR 16-1 standard and having a 6.5" 
color LCD is an addition to the well-proven 
Rohde&Schwarz EMI test receiver family. It cov- 
ers the entire frequency range from 9 kHz to 
2.75 GHz, making it well-suited for performing 
in a wide variety of commercial EMI tests. 

Test Receiver ESCS30 combines three types of 
instruments in one: 

► A portable, manually tunable test receiver 
with built-in battery 

► An automatic test receiver which as a stand- 
alone unit performs measurements and 
reports the results 

► A system-compatible test receiver with IEEE 
488-bus interface which supports EMI soft- 
ware packages running under Windows 

Due to the optional built-in Ni-MH battery and 
an advanced power-saving circuit, the ESCS30 
satisfies all requirements for portable mobile use. 



POWERFUL FIRMWARE FUNCTIONS 

► Macros for automatic and interactive 
test routines 

► Frequency scan over up to 400 user- 
selectable channels 

► Automatic level calibration 

► Automatic consideration of frequency- 
dependent transducer factors 

► Nonvolatile storage of nine complete instru- 
ment settings, 22 difference antenna factors 
and limit lines with up to 50 reference values 

OPTIMUM RESULT DISPLAY FOR EVERY 

APPLICATION 

► 16.5 cm (6.5") TFT color LCD for display of 
interference spectra, including limit lines 

► Clear digital level indication with 0.1 dB res- 
olution on separate level display 

► Quasi-analog display of results in form of bar 
graphs to allow for quick comparison of 
results supplied by the detectors 

► Time domain analysis (oscilloscope mode) for 
measurement of pulse widths and amplitudes 



250 



E M I / R F I 



SOLUTIONS 



www.tektronix.com/Measurement/conimtest/ 





EMI Test Receiver 

ESCS30 



with a display range from 5 ms to 1 hr. 

► IF spectrum analysis with 10 MHz 
display range for visual check of 
spectrum (Opt. ESCS-B4) 

FULL STORAGE AND LOGGING OF 

RESULTS 

► Built-in 3.5 in. disk drive for storing 
test results and instrument settings; 
PC compatible 

► Storage of test results and test reports 
as HP-GL file for simple postprocess- 
ing with word processing programs 

► Output of results as lists and diagrams 
including limit lines and user-defin- 
able labeling; the complete and con- 
clusive test report with user comments 
can be output on a (pin, inkjet or 
laser) printer or plotter, also in color 



Characteristics 



Frequency Range - 9 kHz to 2750 MHz. 
Frequency setting: 

With tuning knob: In 10 Hz, 100 Hz, 

100 kHz steps or user-defined step size 
(switch-selected). 

RF Input - 50 O, N female. 

RF attenuator: 0 to 60 dB, 5-dB steps. 
Preamplifier - 
Gain: 10 dB nominal. 

Maximum Input Level - 
RF attenuation 0 dB: 

DC voltage: 50 V. 

Sinewave AC voltage: 130 dBpV. 

Pulse spectral density: 97 dBpV/MHz 
(100 Vx 0.5 ns). 

RF attenuation >10 dB: 

DC voltage: 50 V. 

Sinewave AC voltage: 137 dBpV (1 W). 
Maximum pulse voltage (10 ps): 150 V. 
Maximum pulse energy (20 ps): 10 mWs. 



Displayed Noise Level (Average) - 

Range Preamplifier off Preamplifier on 



9 kHz to 30 MHz 


BW = 200 Hz 


<-25 dBpV 
typ. -28 dBpV 


<-34 dBpV 
typ. -38 dBpV 


50 kHz to 30 MHz 


BW = 9kHz 


<-12 dBuV 


<-18 dBpV 


30 to 1000 MHz 


BW=120kHz 


<+l dBpV 
typ. -1 dBpV 


<- 4 dBpV 
typ. -7 dBpV 


1000 to 2750 MHz 


BW=120 kHz 


<+5 dBpV 


<0 dBpV 



Level Display - 

Digital in dBpV, dBpA, dBm, dBpV/m, dBpA/m, 
dBpW, dBpT: 3 1/2 -digit LCD, resolution 0.1 dB. 
Analog: on analog meter in operating range of IF 
detector with digital display of lower range limit. 
Bar graph display: Horizontal bar on the screen. 
Screen - 6.5 in. TFT color LCD. 

Resolution: 640 x 480 pixels (VGA). 

Time Domain Analysis - 

Display range (sweep time): 5 ms to 10,000 s. 

Minimum resolution (x axis): 100 ps. 

IF Spectrum Analysis (Opt. ESCS-B4) - 
Display range: 10 kHz to 10 MHz, 1/2/5 steps. 

IF input attenuation: 0/20 dB (selectable). 
Resolution: 1/3/10 kHz. 

Sweep time: 50 ms to 10 s, 1/2/5 steps. 
Level display range: 80 dB. 

Demoduiation Modes - 
AM, FM, AO (zero beat). 

Loudspeaker: Built-in loudspeaker, head- 
phones connection. 

Date, Time of Day - Built-in dock module, 
continuously active, fed from internal battery. 

Internal Memory - 

Transducer: 22 transducer factors with up to 
50 values, nonvolatile, combinable. 

Limit lines: 22 limit lines with up to 50 values, 
nonvolatile. 

Instrument settings: Nine complete setups, 
nonvolatile. 

Documentation - 

Plotter (lEC/IEEE bus) or printer (Centronics): 
Graphs with limit lines, settings and com- 
ments, complete test reports, lists with 
frequency and level. 

Scaling of graphs: lin or log frequency axis. 



CONNECTORS AND INTERFACES 
Remote Control - Interface to IEC625.2 
(IEEE488.2). 

Remote-control connector: 24-Pin Amphenol. 
Floppy Disk Drive - 3.5 in., 1.44 MB (format- 
ted) for saving instrument settings, measure- 
ment results, transducer factors and limit lines. 
Tracking Generator (Opt. ESCS-B5) - 
Generator output: 50 D, N female. 

Frequency range: 9 kHz to 2750 MHz. 

Output level: 90 dBpV, can be electronically 
reduced by maximum 10 dB. 

Frequency response: <2 dB. 

GENERAL DATA 
Power Suppiy - 

AC supply: 100/120/230/240 V ±10%, 47 to 
420 Hz (60 VA). 

Battery, external: 11 to 33 V, 2.5 A at 24 V, 4.7 
A at 12 V. 

Safety - EN61010-1, IEC61010-1. 



PHYSICAL CHARAaERISTICS 
Dimensions mm 



Width 


435 


Height 


236 


Depth 


350 


WcIieM 


ks 


Net 


18.4 


With Opt. ESCS-Bl and 
3 Battery Packs ESCS-B2 


22.9 



ESCS-Bl and ESCS-B2. 




Ordering Information 



For price information: Outside the U.S. contact 

ESCS 30 EMI TEST RECEIVER 

9 kHz to 2750 MHz. 



' local Tektronix representative, inside the U.S. s 

OPTIONS 

Opt. ESCS-Bl - Battery Controller Ni-MH and bat- 
tery support (without battery packs). 

Opt. ESCS-B2 - Ni-MH Battery Pack (maximum 
three packs can be inserted, Opt. ESCS-Bl required). 
Opt. ESCS-B4 - IF Spectrum Analysis. 

Opt. ESCS-B5 - Tracking Generator 9 kHz to 
2750 MHz. 

Opt. ESCS-B6 - OCXO Reference Oscillator. 

Opt. ESCS-B9 - RMS Detector. 



the price list in the back of this catalog. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



www.tektronix.com/Measurement/commtest/ 



EMI/RFI SOLUTIONS 251 









Features - Benefits 



Frequency Range 9 kHz to 30 MHz 
(ESHS) 

Frequency Range 20 MHz to 1 GHz 
(ESVS) 

Frequency Range 5 Hz to 1 GHz 
(ESS) 

Resolution Bandwidths from 2 Hz 
to 1 MHz (ESS) 

Operation from AC Supply or 
External Battery 



Applications 



Measurements to Military 
Standards MIL-STD-461, DEF STAN 
59-41, GAM-EG 13 and VG 95370 
and 95673 (ESS) 

Field-strength Measurements Using 
Test Antennas (ESVS and ESS) 

Conducted Emissions 
Measurements (ESHS and ESS) 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 




Product(s) complies with IEEE 
Standard 488.1-1987, RS-232-C, 
and with Tektronix Standard 
Codes and Formats. 

ROHDE& SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



The number of measurements required to ensure 
electromagnetic compatibility is continuously 
increasing. Thanks to the built-in intelligence of 
the ESHS/ESVS/ESS EMI Test Receivers, the 
time required for such measurements is reduced 
considerably. These test receivers are specialized 
for measurements to the applicable CISPR, CEN- 
ELEC, ETSI, FCC, VCCI and VDE standards. In 
addition, the ESS provides measurements to the 
relevant military standards as well ~ MIL, VG, 
DEF and STAN. 

The ESHS/ESVS/ESS featme high frequency res- 
olution and accurate level indication in peak 
average and quasi-peak detection (ESS provides 
RMS also). The real strength, however, is the 
automatic measurement of RFI voltage, current, 
power and field strength. After a fast pre-scan 
measurement, it compares the results with pre- 
scribed limits, displays the interference spectrum 
with the limits on the screen, and furnishes a 
comprehensive test report with all the necessary 
information. The time-consuming quasi-peak 
measurement is only carried out in cases where 
the peak value is close to the relevant limit. 

EMI TEST RECEIVER FEATURES 

The ESHS 10. ESHS 30, ESVS 10, ESVS 30 and 
ESS share the same basic design and perform- 
ance characteristics. The various models provide 
differing features which provide full EMI meas- 
urement performance from 5 Hz to 1 GHz. All 
models feature an excellent price/performance 



ratio, compact design, high measurement speed, 
and great operating convenience. Following are 
the primary features, shared by all instruments 
unless noted otherwise: 

RF SECTION 

► High pulse loading capacity of calibrated 
attenuator 

► Comprehensive preselection filters 

► Switchable preamplifier with wide 
dynamic range 

► Crystal-stabilized, fast synthesizer with high 
resolution and sweep 

DEMODULATION 

► Parallel detectors for average, peak and 
quasi-peak indication (ESS also provides 
RMS indication) 

► AM and AO demodulators (ESVS and ESS 
also provide FM demodulation) 

► Logarithmic amplifier with more than 70 dB 
dynamic range 

► Automatic overload detection in the mixer 
stages and in the test channel by permanently 
activated peak detectors 

POWERFUL PROCESSOR SYSTEM 

► Macros for automatic and semi-automatic 
test runs 

► 12-Bit A/D converter with short conversion 
time 



252 EMI/RFI SOLUTIONS 



www.tektronix.com/Measurement/commtest/ 






EMI Test Receivers 

ESHS • ESVS • ESS 



► Measurement time selectable 
between 1 ms and 100 s 

► Nonvolatile storage of 10 complete 
instrument setups and 22 different 
transducer factors and limit lines 

OPTIMAL DISPLAY OF RESULTS 

FOR EVERY APPLICATION 

► Measurement of voltage, field 
strength, current and pulse spectral 
density with full indication of units 

► Indication of level on analog meter 
and digital readout with 0.1 -dB reso- 
lution 



► IF analysis for visual check of inter- 
ference spectrum in manual measure- 
ment mode (ESHS 30, ESVS 30, ESS) 

► Built-in tracking generator for atten- 
uation and gain measurements 
(ESHS 30, ESVS 30, ESS) 

STORAGE AND LISTING OF RESULTS 

► Built-in 3.5 in. disk drive for storing 
test results and instrument settings 
(ESHS 30, ESVS 30, ESS) 

► Output of results as lists and dia- 
grams on printer or plotter including 
limit lines and user-definable labeling 



SIMPLE OPERATION 

A combination of hardkeys and softkeys 
ensures simple operation and fast access 
to the menu functions. All models have 
the classic test receiver controls on the 
right of the front panel for manual set- 
tings. The left section of the front panel 
is used to edit data for automatic test 
runs, tables for limit values and trans- 
ducer factors (for example, for current 
and voltage probes and antennas), as 
well as special functions and the infor- 
mation required for test reports. 



Characteristics 





ESHS 


ESVS 


ESS 


Frequenqr Related 


Frequency Range 


9 kHz to 30 MHz 


20 MHz to 1 GHz 


5 Hz to 1 GHz, subdivided 
into the following ranges: 


Range 1 






5 Hz to 50 kHz 
(tunable down to 1 Hz) 


Range il 






9 kHz to 30 MHz 


Range 111 






20 MHz to 1 GHz 



(automatic range selection, 
depending upon IF bandwidth 
and RF input (balanced/unbalanced)) 



RF Input 



Connector 


N connector, female 


N connector, female 




5 Hz to 1 GHz, 
unbalanced 
5 Hz to 50 kHz, 
balanced 






N connector, female 






Twinax connector, female 


Impedance 


50 Q 




50 n 


50 n 


Preamplifier 


Switchable between input Switchable between input Switchable between input 




filter and 1st mixer 


filter and 1 st mixer filter and 1 st mixer 


Gain 


10 dB 




10 dB 


10 dB 


IF Band widths 












Nominal 






Shape Factor 


(Selectable in Range) Bandwidth 


-3 dB (±20%) -6 dB 


BWeds/BWSO 


ESHS 


200 Hz*i 


140 Hz 


200 Hz +20/-30 Hz 


1 :8 typical 




10 kHz*2 


7 kHz 


9.5 kHz +0.5 kHz 


1:3.5 typical 


ESVS 


10 kHz 


7 kHz 


9.5 kHz ±0.5 kHz 


1 :4 typical 




120 kHz 


90 kHz 


120 kHz +10% 


1:5.5 typical 


ESS 


2 Hz 


1.4 Hz 


2 Hz 


1:2.5 (1) 




5 Hz 


3.5 Hz 


5 Hz 


1:2.5 (1) 




10 Hz 


7 Hz 


10 Hz 


1:2.5 (1) 




20 Hz 


14 Hz 


20 Hz 


1:2.5 (1) 




50 Hz 


35 Hz 


50 Hz 


1:2.5 (l+ll) 




100 Hz 


70 Hz 


100 Hz 


1:2.5 (l+ll) 




200 Hz 


140 Hz 


200 Hz 


1:2.5 n(l+ll) 




500 Hz 


350 Hz 


500 Hz 


1:2.5 (l+ll+lll) 




1 kHz 


700 Hz 


1 kHz 


1:2.5 (l+ll+lll) 




0 kHz‘5 


7 kHz 


9.5 kHz ±10.5 kHz 


1:4 (ll+lll) 




100 kHz 


70 kHz 


100 kHz 


1:5 (ll+lll) 




120 kHz 


90 kHz 


120 kHz 


1:5 (ll+lll) 




1 MHz 


700 kHz 


1 MHz 


1:5 (ll+ill) 


Meets tolerances to CISPR 1 6. 




MIL tolerances (10 kHz ± 1 0% ). 


Meets tolerances to CISPR 16 (minimum 


Complies with tolerances to CISPR and MIL 


8 kHz, 10 kHz maximum) and complies with 


tolerances of 10 kHz ±10%. 



DISPLAY RELATED 
Level Display - 

Digital, Digits: 3 1/2. Resolution: 

0.1 dB., Units: dBpV, dBpA, dBm, dBpV/m, dB|j 
A/m, dBpV/MHz, dBtjA/MHz, dBtjV/m/MHz, d 
BpA/m/MHz, dBpW, dBpT. Analog: Moving-coil 
meter in operating range of IF detector with 
additional digital display of lower range limit. 
Operating ranges: 30, 60 dB. 

Screen (ESHS 30, ESVS 30, ESS) - 
(RF analysis), 

Display: 5 in. CRT with digital video memory. 
Resolution: 1024 x 1024 pixels. 

Display range, 

X axis (frequency): Freely selectable, linear 
or logarithmic (ESS, maximum 1 GHz). 

Y axis (level): 10 to 200 dB, adjustable. 
Marker Functions: Marker, delta marker, mark- 
er set to maximum, receiver frequency set to 
marker frequency. 

Display Modes (detectors) - Average (AV), 

RMS (ESS only), peak (PK), spectral density 
measurement (PK/MHz), quasi-peak (QP). 
Averaging, Hold and Measuring Times: 1 ms to 
100 s (1-2-5 steps). 

Demodulation Modes - 
(ESHS), AO (zero beat); A3 (for A3E emissions). 
(ESVS, ESS), AO (zero beat); A3 (for A3E 
emissions); F3 (for F3E). 

Date, Time of Day - Internal clock, perma- 
nently operated from internal battery. 

INPUT/OUTPUT 

Floppy Disk Drive (ESHS 30, ESVS 30, 

ESS) - 3.5 in., 1.44 MB formatted. 

Formatting: MS-DOS compatible. Data format 
HP-GL or binary. 

Remote Control - lEC 625-2 (IEEE 488). 
Connector: 24-contact Amphenol connector. 
Front-panel Outputs - 
Supply and Coding Connector for Antennas, 
etc: 12-contact Tuchel connector. 

AF Output, Connector: JK34 jack. 



www.tektronix.com/Measurement/commtest/ 



EMI/RFI SOLUTIONS 253 




EMI Test Receivers 

ESHS • ESVS • ESS 



Impedance: 10 ohm. 

EMF: Adjustable up to 1.5 V. 

Generator output 9 kHz to 1 GHz; (ESHS 30, 
ESS). 

Connector: N female. 

Impedance: 50 Q. 

EMF: 96 dBpV±l dB. 

Noise indication 

ESHS 



POWER REQUIREMENTS 
AC Operation - 

Line Voltage: 100 V, 120 V, 220 V, 240 V ±10% 
(ESS, 230 V +6%/-10o/o). 

Line Frequency: 47 to 440 Hz. 

Power Consumption: ESHS 10, 50 VA; ESVS 10, 

Preamplifier off Preamplifier on 



Average value, BW 200 Hz 
fin 9 to 50 kHz 
fin >50 kHz 

Average value, BW 10 kHz 
fin >50 kHz 

Peak value (typical increase against average value) 

Quasi-peak 

Band A 

9 to 50 kHz 

50 to 150 kHz 

Band B >150 kHz 

PK/MHz^ 

ESVS 

Average value 
BW 10 kHz 
BW 120 kHz 
Peak value 
BW 10 kHz 
BW 120 kHz 
Quasi-peak Band C/D 

PK/MHz (spectral density measurenient, BW 120 kHz) 

ESS 



<-24 to <-30 dBpV <-30 to <-36 dBpV 

<-30 dBpV, -35 dBpV typical <-36 dBpV, -41 dBpV typical 



<-14 dBpV, -17 dBpV typical 
+11 dB 



<-20 dBpV, -25 dBpV typical 
+11 dB 



-24 to -30 dBpV typical 
-32 dBpV typical 
-13 dBpV typical 
34 dBpV/MHz typical 



-30 to -36 dBpV typical 
-38 dBpV typical 
-19 dBpV typical 
28 dBpV/MHz typical 



<-12 dBpV, -15 dBpV typical <-16 dBpV, -21 dBpV typical 
<-l dBpV, -4 dBpV typical <-5 dBpV, -10 dBpV typical 



-4 dBpV typical 
+7 dBpV typical 
+2 dBpV typical 
25 dBpV/MHz typical 



-9 dBpV typical 
+1 dBpV typical 
-4 dBpV typical 
21 dBpV/MHz typical 



Average value. Range I 
BW 2 kHz, fin = 5 to 30 Hz 
BWlOkHz, fin = >30 Hz 
Average value. Range II 
BW200 kHz, fin = 9 to 50 Hz 
BW 200 kHz, fin =>50 Hz 
Average value, Range III 
BW 120 kHz 

RMS value (typical Increase vs. average reading) 
Peak (PK) value (increase vs. average reading) 



<-38 to -48 dBpV typical 
<-40 dBpV, -44 dBpV typical 

<-24 to -30 dBpV typical 
<-30 dBpV, -35 dBpV typical 



<-38 to -52 dBpV typical 
<-41 dBpV, -48 dBpV typical 

<-30 to -36 dBpV typical 
<-36 dBpV, -41 dBpV typical 



<1 dBpV, -6 dBpV typical <-5 dBpV, -10 dBpV typical 
+1 dB +1 dB 

+11 dB +11 dB 



60 VA; ESHS 30, 80 VA; ESVS 30, 90 VA; ESS, 
llOVA. 

DC Operation - Internal Battery (ESHS 10, 
ESVS 10): 12 V, 10 AH. 

Operating Time: 

ESHS 10: « 4 hours; 

ESVS 10: « 2.5 hours. 

External Battery - Voltage Range: 11 to 33 V. 
Current Drain 24/12 V: ESHS 10, 1.2 A/2.3A; 
ESVS 10, 1.9 A/3.3A; ESHS 30, 2.1 A/3.9 A; ESVS 
30, 2.6 A/4.8 A; ESS, 3A/5.5A. 

GENERAL SPECIFICATIONS 



Physical Characteristics 

Dimensions mm in. 



Height 




236 


9.3 


Width 




435 


171 


Depth 


ESHS 10 


363 


14.3 




ESHS 30 


463 


18.2 




ESS 


572 


22.5 


Weight 




h* 


lb. 


ESHS 10 without battery 


18 


39.7 


ESVS 10 without battery 


20.4 


45 


ESHS 10 with battery 


21 


46.3 


ESVS 10 with battery 


23.7 


52.2 


ESHS 30 




28.6 


63.1 


ESVS 30 




26.4 


58.2 


ESS 




32.1 


70.8 



your local Tektronix representative, inside the U.S. see 



Ordering Information 



For price information: Outside the U.S. contact 

ESHS 10 

EMI Test Receiver. 

Includes: Power Cord, Manual. 

ESHS 30 

EMI Test Receiver. 

Includes: Power Cord, Manual. 

ESVS 10 

EMI Test Receiver. 

Includes: Power Cord, Manual. 

ESVS 30 

EMI Test Receiver. 

Includes: Power Cord, Manual. 

Opt. OI/ESVS-BI - Pulse Power Attenuator. 
Maximum pulse voltage 1500 V. 



ESS TEST RECEIVER 

EMI Test Receiver. 

Includes: Power Cable, Connector for External 
Battery, N-BNC Adapter, Sun Shield for Screen (ESS 
only). Manual. 

Opt. 01/ESS-BI - OCXO Reference Oscillator. 

1 X 10-7 setting error, 1 x lO-^day aging error and 
1 X 10"7‘*C temperature drift 

MEASUREMENT SERVICE OPTIONS ESHSIO: 
Opt. C3 - Three years of Calibration Services. 

Opt. D1 - Cal Data Report. 

Opt. D3 - Test Data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover 
three years. 



the price list in the back of this catalog. 

ADDITIONAL ACCESSORIES 

Also see page 495. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503>627-1916. inside the U.S. call: 1-800-426-2200. 




Product(s) complies with IEEE Standard 488.2-1987. 

ROHDE& SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



254 EMI/RFI SOLUTIONS 



www.tektronix.com/Measurement/commtest/ 





EMI/Radio Monitoring Solutions 



ESVB • ESVD • ESVN • ESN 




Features - Benefits Applications 



Frequenq^ Range 20 MHz to 1 GHz 
(2.05 GHz with Opt 02) (ESVB) 

Frequenq^ Range 20 MHz to 1 GHz 
(2.05 GHz with Opt. 02) (ESVD) 

Frequency Range 20 MHz to 1 GHz 
(ESVN) 

Frequency Range 9 kHz to 1 GHz 
(2.05 GHz with Opt 01) (ESN) 

Frequency Accuracy to GSM 
Recommendations (ESVD) 

In-phase and Quadrature Output 
for Evaluating Any Modulated 
Signal (ESVD) 

Remote Control via IEEE 488 
Interface 

Operation from AC Supply or 
Internal/External Battery (ESVN) 

Operation from AC Supply or 
External Battery (ESN) 



Field-strength Measurements Using 
Test Antennas 

Radio Monitoring to CCIR 
Coverage Measurements 

Selective Voltage Measurements in 
Labs and Test Shops 

Radio Interference Measurements 
to EN 5501 1 to 55022, ETS, FCC 
and ANSI C63.4, VCCI, and VDE 
0871 to 0879 

Digital Audio Broadcasting 
Networks (ESVB) 

Mobile Radio Networks - GSM, 

PCN (ESVD) 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 




Product(s) complies with IEEE 
Standard 488.1-1987, 
and with Tektronix Standard 
Codes and Formats. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



Introduction 

The ESVB/ESVD/ESVN/ESN Test Receivers are 
ideal instruments for all applications in the 
fields of radio monitoring and radio network 
planning, civil RFI measurements to all relevant 
standards, as well as for selective voltage and 
two-port measurements in manual and automatic 
mode. ESVB/ESVD/ESVN/ESN are used to meas- 
ure and demodulate both amplitude-modulated 
(DSB, SSB pulse) and frequency-modulated sig- 
nals, as well as narrowband and broadband 
interference in the range from 20 MHz to 1 GHz 
(ESVN), 9 kHz to 2.05 GHz (ESN), and 20 MHz 
to 2.05 GHz (ESVB/ESVD Opt. 02). 

Manual operation or automatic mode, with spec- 
trum display on screen and reports of results on 
printer or plotter, make these Test Receivers 
extremely versatile for many applications. 



TEST RECEIVER FEATURES 

The ESVB/ESVD/ESVN/ESN Test Receivers com- 
bine three different types of test receivers in one: 

► A compact, manually tuned and battery-oper- 
ated test receiver 

► A test receiver which automatically performs 
measurements and reports the results 

► A system-compatible test receiver 
Following are the primary features which are 
shared by all instruments unless noted otherwise: 



www.tektronix.com/Measurement/commtest/ 



E M I / R F 



SOLUTIONS 



255 





EMI/Radio Monitoring 

ESVB • ESVD • ESVN • ESN 



RF UNIT 

► High measurement accuracy: error 
<1 dB, <0.5 dB typical 

► Refined preselection 

► Switchable preamplifier with wide 
dynamic range 

► Crystal-stabilized synthesizer (ESN): 
sweep mode for fast frequency 
scans, frequency resolution down to 
10 and 100 Hz 

► Wide dynamic range: noise figure 
typically 7 dB with preamplifier, 

12 dB without preamplifier, third- 
order intercept point typically 

20 dBm (without preamplifier) 

► Tracking generator for attenuation 
and gain measurements with ESVN 
30 and ESN (9 kHz to 1 GHz) 

► High-level mixer ensuring high sup- 
pression of 1st LO 

► IF analysis with resolution band- 
width of 1, 3 and 10 kHz; span 0.01 
to 10 MHz; runs in parallel with 
level measurements 

DEMODULATION 

► High-linearity envelope detector 
with dynamic range of more than 
70 dB 

► Peak, average, RMS and quasi-peak 
detectors 

► Automatic overload detection in 
mixer stages and in test channel by 
permanently activated peak detectors 

► Logarithmic amplifier with dynamic 
range of more than 70 dB 

► Demodulators for measuring modu- 
lation depth and frequency and 
phase deviation 

► Demodulator circuits for FM, AM, 
SSB (LSB and USB), zero beat and 1- 
kHz beat 

► Built-in loudspeakers and head- 
phones connector; demodulation 
using signal processors 

► Separate signal channel with 5 MHz 
bandwidth and demodulator for TV 
signals with switchover to all com- 
mon TV standards 



256 EMI/RFI SOLUTIONS 



Solutions 



POWERFUL PROCESSOR SYSTEM 

► Macros for automatic test runs 

► Test runs over up to 400 freely selec- 
table channels with programmable 
thresholds 

► Automatic level calibration and con- 
sideration of frequency-dependent 
transducer factors (e.g., of antennas) 

► Non-volatile storage of 10 complete 
instrument setups, 22 different 
antenna factors and limit lines 

► Built-in 3.5 in. floppy disk drive 

► Output of results as lists and dia- 
grams on plotter or printer including 
limit lines and user-defined labeling 

OPTIMAL DISPLAY OF RESULTS 
FOR EVERY APPLICATION 

► Measurement of voltage, field- 
strength and current with full indi- 
cation of units 

► Level indication on analog meter and 
digital display with 0.1 dB resolution 

► Display of modulation depth, devia- 
tion and frequency or frequency off- 
set with very high resolution 

► Display of frequency spectra (RF 
ANALYSIS) including limit values 

► IF analysis with spans of up to 
10 MHz 

► Connector for TV monitor to identify 
TV programs 

MANUAL MODE 

These test receivers perform measure- 
ments at a fixed frequency with the 
desired bandwidth, attenuation, meas- 
urement time and display mode. Level 
measurement, modulation, and devia- 
tion measurement, as well as frequency 
and frequency offset measurement, are 
carried out simultaneously. 

While measurements are being per- 
formed, the IF analysis function allows 
the spectrum about the receive frequen- 
cy to be analyzed. Measurement of 
level, modulation, or frequency, as well 
as signal assessment using the built-in 
loudspeaker, are made at the center fre- 
quency of the extended spectrum with 
the settings selected. 



AUTOMATIC MODE 

The receive frequency range is scanned 
and the result displayed as a spectrum 
on the screen. The measurement param- 
eters such as start frequency, stop fi:e- 
quency, IF bandwidth, measurement 
time, attenuation and display mode can 
be freely selected. 

THREE OPERATING MODES FOR 
FREQUENCY SCANNING 

Overview Mode; Frequency scanning 
over the desired frequency range is at 
maximum speed and with fixed attenu- 
ation. 

Scan Mode: Frequency scanning is 
quasi-continuous with selectable step 
size and measurement time as well as 
automatic attenuation setting. 

Channel Mode: Frequency scanning 
over a defined data set with up to 400 
frequencies. 

DOCUMENTATION OF RESULTS 

The results, along with all relevant 
information, can be output in graphical 
form or as lists on a plotter or printer. 

In addition, data can be stored on a 
floppy disk along with the complete 
receiver setup. 

USE IN COMPUTER-CONTROLLED 
SYSTEMS 

Full use of the high measurement rate 
of these test receivers is possible only 
in the remote mode using a high-speed 
controller. In the determination of field- 
strength profiles, the receivers furnish 
5,000 measured values per second after 
being triggered by a positioning system 
or a time base. 

For radio monitoring, up to 10,000 fre- 
quencies can be stored in the receivers 
and scanned at high speed with range- 
related receiver settings. The results are 
then output to the process controller. 



www.tektronix.com/Measurement/comintest/ 



EMI/Radio Monitoring Solutions 

ESVB • ESVD • ESVN • ESN 



Table i 

ESVB/ESVD Nominal Bandwidth -ldB(llO%) -6dB(±I0%) Shape Factor 



BW,^w'BW„a 



10 kHz 


7 kHz 


9.5 kHz 


1:4 typ. 


120 kHz 


90 kHz 


120 kHz 


1:5 typ. 


300 kHz 


300 kHz 


400 kHz 


1:6 typ. 


1 MHz 


800 kHz 


1 MHz 


1:4 typ. (ESVD) 


1.5 MHz 


1.5 MHz 


1.8 MHz 


1:2.7 typ. (ESVB) 



Table 2 



ESVB/ESVD Noise Indication 


Preamplifier off 


Preamplifier on 


20 to 1000 MHz 


Average value, BW - 10 kHz 


< -12 dBpV, typ. -16 dBpV 


_ <-16dBpV,typ.-20dBpV 


BW - 120 kHz 


typ. -5 dBpV 


typ. -9 dBpV 


BW - 300 kHz 


typ. 0 dBpV 


typ. -4 dBpV 


BW - 1 MHz 


typ. 4 dBpV (ESVD) 


typ. 0 dBpV (ESVD) 


BW - 1.5 MHz 


typ. 7 dBpV (ESVB) 


typ. 3 dBpV (ESVB) 


1000 to 2050 MHz 


Average value, BW - 10 kHz 


< -10 dBpV, typ. -15 dBpV 


< -16 dBpV, typ. -20 dBpV 


BW- 120 kHz 


typ. -3 dBpV 


typ. -9 dBpV 


BW - 300 kHz 


typ. 2 dBpV 


typ. -4 dBpV 


BW-1 MHz 


typ. 6 dBpV (ESVD) 


typ. 0 dBpV (ESVD) 



BW - 1.5 MHz typ. 9 dBjiV (ESVB) typ. 3 dBpV (ESVB) 

Table 3 

ESN/ESVN Nominal Bandwidth -3 dB (±20%) -6 dB Shape Factor 

BWeWBWsodB 

1 kHz 1 kHz 1.2 kHz ±20% 01 :02.8 

3 kHz 3 kHz 3.15 kHz ±10% 01:01 .8 

9 kHz*^ 7 kHz 9. 5 kH z ±20% .51i02;2 

15 kHz 15 kHz 17 kHz ±10% 01 :01.8 

120 kHz*^ 90 kHz 120 kHz ±20% 1:05 

250 kHz 250 kHz 330 kHz ±10% 01:03.7 

Meets tolerances to CISPR 16. 

Table 4 

ESN/ESVN Noise Indication Preamplifier off Preamplifier on 

Average value, BW 1 kHz 

Range I (fin >50 kHz) <-22 dBpV, -17 dBgV typical <-28 dBpV, ~33 dBpV typical 



Range II 


<-18 dBpV, -23 dBpV typical 


<-22 dBpV, -28 dBpV typical 


Range III 


<-16 dBpV, -22 dBpV typical 


<-22 dBpV, -28 dBpV typical 



1 Characteristics I 


FREQUENCY RELATED 
Frequency Range - 

ESVB/ESVD/ESVN 


ESN 


Range 1 

Range II 20 MHz to 1 GHz 


9 kHz to 30 MHz 
30 MHz to 1 GHz 


Range III 1 GHz to 2.050 GHz 
(ESVB/ESVD) 


1 GHz to 2.050 GHz 
(with Opt. 01) 


Frequency Setting - 



With tuning knob: Fine, coarse or any step size 
selectable. 

Numerical: Via keyboard entry. 

Step size: Any selectable size. 

Automatic scanning: For RF analysis. 
Frequency Display - 8-digit LCD. 

Resolution - 
Range 1: 10 Hz. 

Range II and III: 100 Hz. 

Frequency Error - ESVN: <3 x 10"®. ESN and 
ESVN with Option 01 (after 30 minutes warm- 
up): <1 X 10-7. 

Temperature Drift - <1 x lO'V^C. 

Aging - <1 X 10-7/year. 

RF INPUT 

Connector - N connector, female. 

Impedance - 50 Q. 

RF Attenuator - 0 to 120 dB, switchable in 
10 dB steps. 

Input Filters - 

Range I: Five fixed-frequency bandpass filter. 
Range II: One fixed-frequency and five tracking 
bandpass filters. 

Range III: Four fixed-frequency bandpass filters. 
Preamplifier - Can be connected between 
input filter and 1st mixer. Gain: 10 dB. 

Maximum Input Level (with and without 
preamplifier) - 

RF Attenuation 0 dB (AC-coupled); DC Voltage: 
50 V. Sinewave AC Voltage: 130 dBpV. Spectral 
Pulse Density: 97 dBpV/MHz. 

RF Attenuation >0 dB (DC-coupled); 

DC Voltage: 7 V (corresponds to 1 W). 
Sinewave AC Voltage: 137 dBpV. Maximum 
Pulse Voltage: Range 1, 700 V; Range II and III, 
150 V. Maximum Pulse Energy: Range 1, 100 
mWs; Range II and III, 1 mWs. 

IF Bandwidths - ESVB/ESVD: See Table 1, 
ESVN/ESN:SeeTable3. 



Voltage Measurement Range - 

Lower Limit (additional error caused by inher- 
ent noise <1 dB); Average Value (AV): 4 dB 
above noise indication. RMS Value (RMS): 5 dB 
above noise indication. Peak Value (PK): 15 dB 
above noise indication. Quasi-peak (QP) 

(100 Hz pulse frequency): 3 dB above noise 
indication. 

Upper Limit (AV, RMS, PK, QP): 137 dBpV (RF 
attenuation >0 dB). 

Inherent Spurious Response (equivalent input 
voltage); Range I: <-10 dBpV. Range II and III: 
<0 dBpV. 



DISPLAY RELATED 
Level Display - 

Digital; Digits: 3. Resolution: 0.1 dB. Units: 
dBpV, dBpA, dBm, dBpV/m, dBpA/m, dBpW. 
Analog: Moving-coil meter in operating range 
of IF detector with additional digital display of 
lower range limit. 

Operating ranges: 30, 60 dB. 

Screen - 

Display: 5 in. CRT with digital memory. 
Resolution: 1024 x 1024 pixels. 

Display range; X axis (frequency): Freely selec- 
table, linear or logarithmic. Y axis (level): 10 to 
200 dB, adjustable In 10 dB steps. 



www.tektronix.com/Measurenient/coniintest/ 



EMI/RFI SOLUTIONS 257 





EMI/Radio Monitoring Solutions 

ESVB • ESVD • ESVN • ESN 



Indication Modes - Average value (AV), RMS 
value (RMS), peak value (PK), quasi-peak value 
(QP, fjn >150 kHz). Measurement time: 1 ms to 
100 s (1-2-5 steps). 

Frequency Deviation (Digitai in kHz) - 

Resolution: 0.1/0.01 kHz. Measurement Range: 
Deviation + fmod <0-5 IF bandwidth. 
Measurement Frequency fmod- KlOO kHz. 
Measurement Error (signal-to-noise >40 dB, AF 
= 1 kHz); IF Bandwidths 1, 3, 9, and 15 kHz: 

100 Hz + 3% of measured value. IF Bandwidths 
120 and 1250 kHz: 2 kHz + 3% of measured 
value. 

Phase Deviation (Bandwidths 1, 3, 9, 

15 kHz) - 

Resolution: 0.1. Maximum Deviation: 8 rad. 
Modulation Frequency: 300 Hz to 5 kHz. 
Measurement Error (signal-to-noise >40 dB, m 
= 50%, AF = 1 kHz): 0.1 rad + 5% of measured 
value. 

Modulation Depth (Digitai in %) - 

Resolution: 0.1%. Measurement range 1 to 
99%. Modulation Frequency fmod- <100 kHz. 
Measurement Error (signal-to-noise >40 dB, m 
= 50%, AF = 1 kHz): 5% (absolute). 



IF Analysis - 

Frequency Display; Range 1: 10 kHz to 2 MHz 
(1-2-5 steps). Range II and III: 10 kHz to 
10 MHz (1-2-5 steps). 

Level Display Range: 80 dB. 

Attenuation Switchover (in IF path): 0/20 dB. 
Resolution Bandwidth (-3 dB): 1, 3, 10 kHz. 
Sweep Time: 50 ms to 10 s (1-2-5 steps). 
Number of Test Curves: Maximum 2 traces. 

AF Demodulation Modes - Zero beat, 1 kHz 
beat, AM (for A3E emissions), USB and LSB 
(for SSB emissions), FM (for F3E emissions). 
Squelch: Adjustable with front-panel knob. 
Trigger Functions - External: TTL level, posi- 
tive- or negative-going edge. Internal: 
Controlled by RF level, threshold adjustable. 
Date, Time of Day - Internal clock, perma- 
nently operated from internal battery. 

INPUT/OUTPUT 

Remote Control - lEC 625-2 (IEEE 488). 
Plotter - Via lEC/IEEE-bus interface. Plotter 
Language: HP-GL. 

Printer - Connector: 15-contact Cannon con- 
nector, Parallel interface. 

Keyboard - Connector: 5-contact DIN female. 
Floppy Disk Drive - 3.5 in., 1.44 MB format- 
ted, MS-DOS compatible. 



Front-panel Outputs - Supply and Coding 
Connector for Antennas, etc: 12-contact Tuchel 
connector. 

AF Output - 

Connector: JK34 jack. Impedance: 10 Q. EMF: 
Adjustable up to 1.5 V. 

Generator output (tracking generator): (ESVN 
30, ESN); Connector: N female. Impedance: 

50 Q. Bandwidth: ESVN 30, 20 MHz to 1 GHz; 
ESN, 9 kHz to 1 GHz. EMF: 96 dBpV ±1 dB. 

POWER REQUIREMENTS 
AC Operation - Line voltage: 100 V, 120 V, 
220 V, 240 V ±10o/o: 230 V +60/0/-IO0/0. 

DC Operation - External Battery (switch-on 
voltage >12 V); Voltage Range: 11 to 33 V. 



Physical Characteristics 

Dimensions mm in. 



Height _ 


236 


9.3 


Width 


435 


171 


Depth 


ESVN 


460 


18.1 


ESN 


572 


22.5 


Weight 


k* 


lb. 


ESVN 


29 


63.9 


ESN 


32 


70.5 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 



ESVB 

Test Receiver. 

Includes: Power Cable, Manual. 

Opt. 01/ESVD-BI - l/Q Demodulator. 

Opt 02/ESVD-B2 - Frequency Extension to 2.05 GHz. 
(Opt 01 required). 

ESVD 

Test Receiver. 

Includes: Power Cable, Manual. 

Opt 01/ESVD-B1 - l/Q Demodulator. 

Opt OVESVD-BZ - Frequency Extension to 2.05 GHz. 
(Opt 01 required). 

ESVN 20 

Test Receiver. 

Includes: Power Cable, Manual. 

Opt 01/ESS-B1 - Reference Oscillator OCXO. 



ESVN 30 

Test Receiver with Tracking Generator. 

Includes: Power Cable, Manual. 

Opt. 01/ESS-B1 - Reference Oscillator OCXO. 

ESN 

EMI Test Receiver. 

Includes: Power Cable, Connector for External 
Battery, N-BNC Adapter, Viewing Hood, Operating 
Manual. 

Opt. 01/ESN-B1 - Frequency Extension. 1 GHz to 
2.050 GHz operation. 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of Calibration Services. 
Opt. D1 - Cal Data Report. 

Opt. D3 - Test Data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover 
three years. 

ADDITIONAL ACCESSORIES 

Also see page 495. 




Product(s) complies with IEEE Standard 488. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



258 EMI/RFI SOLUTIONS 



www.tektronix.com/Measurement/commtest/ 




EMI Software 

ES-Ki 




Features - Benefits Applications 



Fully Automatic and Interactive 
Operation for Maximum Speed, 
Reproducibility and User 
Friendliness 

Automatic Compensation of 
Transducers (Correction Factors) 
and Limit Lines 

Includes Powerful Scripts (Macro 
Routines) for Commonly Performed 
Measurements 

Runs Under Windows 95® and 
Windows NT^ 



Conforms to the following com- 
mercial and military standards: 

COMMERCIAL: 

CISPR 

EN 

ANSI 

FCC 

EACL 

VDE 

MILITARY: 

MIL 

VG 

DEF-STAN 
GAM-EGI 3 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call; 
1-503-627-1916, 
inside the U.S. call; 
1-800-426-2200. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



ES-Kl is an advanced, user-friendly tool which can 
be used for highly effective measurements for all 
conducted and radiated emission measurements. 

When used with Rohde&Schwarz EMI test 
receivers and accessories, the ES-Kl EMI Test 
Software provides fully automatic operation. 
The intereactive mode allows the operation to 
use his/her experience to the fullest for most 



accurate and thorough measurements. At the 
same time, operation under Windows provides 
easy access and operation for the first-time 
user. The friendly graphics user interface 
allows the operator to concentrate on the meas- 
urement at hand. Concise documentation of 
results in graphic and tabular forms is possible 
along with the associated test setup. 



Ordering Information 



For price information: 

Outside the U.S. contact your local Tektronix representative, 

ES-Kl 

EMI Test Software. 

Includes: Program Disks, Manual. 

RECOMMENDED ACCESSORIES 
Script Development Kit - Order ES-K2. 
ESCS/ESHS/ESVS/ESVD Driver - Order ES-K10. 

ESS Driver - Order ES-Kl 1. 



inside the U.S. see the price list in the hack of this catalog. 

ESAI/ESBI/ESMI Driver - Order ES-K12. 

ESVP/ESH3 Driver - Order ES-K13. 

ESVP/ESH3/EZM Driver - Order ES-K14. 

FSA/FSB/FSM Driver - Order ES-K15. 

ESI Driver - Order ES-K16. 

Slideway HCA Driver - Order ES-K31. 

EMCO 1050/1060 Driver - Order ES-K32. 



www.tektronix.com/Measurement/commtest/ 



EMI/RFI SOLUTIONS 259 








EMI Test Receiver ESPC 

EMC-compatible Development and Production 




Features - Benefits Applications 



Correct Interference Weighting to Development and Production 

CISPR 16-1 Down to 10 Hz Pulse Emission Testing of Electrical 
Repetition Frequency Products 

Integrated Preselection 

For All Commercial EMI Standards 
(CISPR, EN, ETS, FCC, ANSI 
C63.4, VCCI and VDE) 

Automatic Overload Detection 

Power Sourcing From Internal or 
External Battery 

Easy-to-use Built-in Macro 
Functions 



Windows-based EMI Software is 
Provided as Standard Accessory 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call; 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 



ISO 9001 



Tektronix measurement 
products are manufactured in 
ISO registered facilities. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



Introduction 

The EMI Precertification Test Receiver ESPC has 
been derived from various Rohde&Schw^arz full- 
compliance receiver models and thus enables 
versatile applications in the field of EMI precom- 
pliance. It is a budget-priced solution for emis- 
sion tests of all stages of development and pro- 
duction of electrical products. 

Featuring built-in preselection, ESPC is able to 
perform accurate interference measurements 
with pulse repetition frequencies (PRF) to as low 
as 10 Hz in accordance with CISPR 16-1. An 
overload detection system for the complete 
receiver signal path, from the input through to 
the IF stages, warns the user of erroneous meas- 
urements. 



SPECIAL FEATURES OF THE ESPC 

► Frequency range from 150 kHz to 1000 MHz 

► Options for frequency extension to 9 kHz and 
2500 MHz 

► Parallel detectors for average, peak and quasi- 
peak reading 

► Fast synthesizer: Frequency resolution 10 and 
100 Hz 

POWERFUL PROCESSOR SYSTEM 

► Macros for automatic and semi-automatic test 
routines 

► Automatic level calibration 

► Measurement of voltage, field strength, cur- 
rent and pulse spectral density with display 
of relevant units 



260 



E M I / R F 



SOLUTIONS 



www.tektronix.com/Measurement/comnitest/ 






EMI Test Receiver ESPC 

EMC-COMPATIBLE DEVELOPMENT AND PRODUaiON 



COMPLETE TESTS AT A KEYSTROKE 

The test receiver automatically selects 
the correct CISPR bandwidths for the 
relevant test frequency. In conjunction 
with firmware macros for automatic test 
routines, comparisons with limit lines, 
for instance to EN standards, can con- 
veniently be made. 

Up to 22 different: 

► Limit lines 

► Transducer factors 

can be stored in a built-in nonvolatile 
memory, ensuring high accuracy for 
every frequency step. 

Users not specialized in EMI can also 
easily handle and carry out these repro- 
ducible test runs. The ESPC shows its 
true strength by making the following 
measurements at the press of a button: 

► RFI Voltage 

► RFI Power 

► RFI Field Strength 

SOFTWARE-SUPPORTED EMI MEAS- 
UREMENTS 

The Windows Software ESPC-Kl sup- 
plied with the ESPC supports EMI 
measurements in accordance with com- 
mercial standards. 



Characteristics 



Data with tolerances are guaranteed values (all 
other data are typical or approximate values). 

FREQUENCY RANGE 

Lower Limit - 150 kHz (optionally 9 kHz with 

ESPC-B2). 

Upper Limit - 1000 MHz (optionally 
2500 MHz with ESPC-B3). 

RF INPUT 

RF Attenuator - 0 to 70 dB, 10 dB steps. 

IF BANDWIDTHS 

Nominal Bandwidth - -3 dB, -6 dB. 

200 Hz* (with Opt. ESPC-B2) - 180 Hz, 

200 Hz. 

10 kHz** - 7 kHz, 9.5 kHz. 

120 kHz* - 90 kHz, 120 kHz. 

Tolerances to CISPR 16-1. 

NOISE INDICATION, AVERAGE 

9 kHz to 3 MHz, BW = 200 Hz with Opt. ESPC-B2. 
150 kHz to 3 MHz, BW=10 kHz. 

Average Indication (AV), f >3 MHz - 

BW=200 Hz: typ. -28 dBpV. 

BW=10 kHz: typ. -12 dpV. 

BW=120 kHz: <+3 dBpV, typ. -2 dBpV. 

Upper Limit AV, PK, QP - 130 dBpV 
(RF attenuation >10 dB). 

LEVEL DISPLAY 
Digital - 

In dBpV, dBpA, dBm, dBpV/m, dBpA/m, dBpW, 
3-digit LCD with backlighting (can be switched 
off), resolution 0.1 dB. 

Analog - On moving-coil meter in operating 
range of IF detector with digital display of 
lower range limit. 



MEASUREMENT ERROR 
Level Calibration - Harmonics generator; 
calibrates the receiver for settings, correction 
values stored in nonvolatile memory, duration 
approx. 1 min. 

Demodulation Modes - AM, FM, AO (zero 
beat), internal loudspeaker, headphones con- 
nector. 

Volume - Adjustable with rotary knob. 

Day, Time of Day - Internal clock, perma- 
nently operated from internal battery. 

INTERNAL MEMORY 
Transducer - 22 transducer factors with up to 
50 reference values, nonvolatile, can be com- 
bined. 

Limit Lines - 22 limit lines with up to 50 ref- 
erence values, nonvolatile. 

Instrument Settings - Nine complete setups, 
nonvolatile. 

CONNECTORS AND INTERFACES 
Remote Control - Interface to IEC625- 
2/IEEE488.2. 

Remote-control Connector - 24-contact 
Amphenol connector. 

Plotter - Via lEC/IEEE-bus interface. 

Printer - Parallel interface (15-contact 
Cannon connector). 

FRONT-PANEL OUTPUTS 
Power Supply - 

AC supply: 100/120/240 V ±10o/o, 230 V 
+6/-10%, 80 VA, 47 to 420 Hz, safety class I 
toVDE0411 (IEC348). 

Battery (external): 11 to 33 V. 

Safety - EN61010-1, IEC61010-1. 



Dimensions 


mm 


Height 


435 


Width 


236 


Depth 


350 


WeiKht 


Its 


Net 


17 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



For your local Tektronix representative see the list in 
the oack of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 



EMI TEST RECEIVER- 

ESPC. Order 1082-8007-10. 

Includes: Windows Software ESPC-Kl, Power Cable, 
Connector for External Battery, Operating Manual. 

PC Configuration Required for Software 
ESPC-Kl - IBM-AT-compatible, 386 or higher. 



OPTIONS 

Internal Battery with Automatic Charging - 

ESPC-Bl. Order 1082-9503-02. 

Frequency Extension 9 kHz to 150 kHz and IF 
bandwidth 200 Hz - ESPC-B2. Order 1082-9555-02. 
Frequency Extension 1000 to 2500 MHz - 

ESPC-B3. Order 1082-9603-02. 




Tektronix measurement products are manufactured 
in ISO registered facilities. 

ROHDE&SCHWARZ 

Rohde & Schwar/ quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



www.tektronix.com/Measurement/commtest/ 



EMI/RFI SOLUTIONS 261 







EMI Measurement System/Software 
New 27120B EMC120 




Features - Benefits Applications 



Configurable System Designed to EMC Diagnostic Work 
Meet Your EMI Testing Needs Prequalification Testing 

Powerful EMC 120 Software Saves 
Time in Acquiring Data and 
Preparing Engineering Reports 

Built-in 2712 Preamp Provides Low 
Noise Floor for Tight Spec Limits 

Diagnose and Correct 
"Hot Spots" Using the 2712 
and Near-Field Probes 

Option 1 1 Includes Antennas, 

Tripod and Cable for Radiated 
Emissions Measurements 



Option 16 Includes LISN and 
Transient Limiter for Conducted 
Emissions Measurements 



Option 17 Provides 2706 RF 
Preselector Which Protects Against 
Signal Overload 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1 - 503 - 627 - 1916 , 
inside the U.S. call: 
1 - 800 - 426 - 2200 . 

C€ 

^ isowi 



Tektronix measurement 
products are manufactured in 
ISO registered facilities. 



The time to address compliance is before it 
becomes a problem. Proper attention to EMC, 
from the design stage through pre-certification 
testing, can reduce your product development 
cost and decrease your time to market. 

Achieve these objectives and more with the 
Tektronix 271 2 OB EMI Measurement System - a 
complete solution for EMI pre- and post-certifi- 
cation of your products. The heart of the system 
is the easy-to-use 2712 Option 12 Spectrum 
Analyzer. It includes many features helpful in 
identifying and measuring EMC signals: 

► Internal preamp 

► Frequency counter 

► AM/FM demodulator 

► True analog display 

► 4-trace digital display 

► Peak. Quasi-peak and Average detection 

► 200 Hz, 9 kHz, 120 kHz EMC filters 



Overload capability is enhanced and ambient 
signal interference is minimized by the 2706 
Stepping RF Preselector (Opt. 17). This may be 
controlled manually or automatically, via IEEE 
488 interface, by the EMC120 software. 

For diagnostic work, the 27120B provides a set 
of two E-field probes, three H-field probes and 
an extender. These allow you to quickly locate 
the source and frequency of radiation. 

Conducted emissions measurements are made 
with Option 16, which includes a 25 Amp LISN 
(Line Impedance Stabilization Network) and a 
Transient Limiter. Radiated emissions measure- 
ments are made with Option 11, which includes 
a biconical antenna and log-periodic antenna. A 
tripod and 10 m low-loss cable are also provided. 

The new EMC120 Windows-based software is a 
feature-filled package that takes the drudgery out 
of EMC testing. It does everything from data 
acquisition, to correcting for transducer factors, 
to graphing and printing final test results. 



262 E M I / R F 



SOLUTIONS 



wvnw.tektroiiix.coni/MeasureneaVcoaintesV 






EMI Measurement System/Software 

NEW 27120B EMC120 




Figure 1. The EMC120 Test Setup Screen. 



EMCi20 - Windows-based 
EMI Software for the 271206 

The EMC120 package is optimized for 
the Tektronix 2712 Option 12 Spectrum 
Analyzer, but it also runs with a stan- 
dard 2712. or a 2711. The EMC120 
automatically controls the Tektronix 
2706 Preselector by switching to the 
appropriate 2706 filter setting as the 
test is being run. 

FILE OPERATIONS 

A library of typical test routines, with 
commonly used limit lines, is provided 
with the software. These support com- 
mercial testing according to standards 
such as CISPR 11, CISPR 22. FCC Part 
15 (Class A and B) and the European 
Norms standards. 

TEST SETUP 

The Test Setup screen (see Figure 1) 
was designed so that commonly used 
spectrum analyzer test parameters are 
readily accessible. These include items 
such as the Start/Stop Frequency, 
Reference Level, Resolution Bandwidth 



and Sweep Speed. A frequency-band 
table allows precise control over each 
acquisition window on the 2712. 

RUNNING THE TEST 

Three detector modes are available 
when using a 2712 Option 12: Peak, 
Quasi-peak, and Average (the Average 
detector is simulated via the 2712 video 
filter). During Peak testing, data may be 
accumulated in Maxhold mode over a 
specified number of sweeps, or the data 
may be accumulated continuously until 
terminated by the user. 

VIEWING THE DATA 

As a test is being run, data is graphed 
as it is acquired. Once a test has com- 
pleted, it’s possible to enable one or 
two markers which provide absolute or 
relative frequency/amplitude values. 

If a Quasi-peak or Average test is being 
run, the graph is drawn and a window 
with Suspect Signals pops up on 
screen. You can then run a test on each 
of these signals, or edit the list (add or 
delete signals) prior to executing the QP 
or Average test. 

REPORT GENERATION 

EMC120 Software has a very versatile 
report generator. Each of the columns in 
the tabular report is user definable and 
can include elements such as the fre- 
quency of the signal, the peak ampli- 
tude, the limit line, etc. 

SYSTEM REQUIREMENTS 

EMC120 Software runs on a PC-compat- 
ible computer equipped with a National 
Instruments GPIB (IEEE 488.2) card. A 
486/33 or faster processor with at least 




Figure 2. Graph of EMC120 data. 



8 MB of RAM is recommended. A VGA 
monitor and hard disk with at least 
10 MB of free space is required. 



Characteristics 



2706 STEPPING RF PRESELEaOR 
(OPT. 17) 

Frequency Range - 9 kHz to 1.8 GHz. 
Bandpass/Highpass Filters - Eight spanning 
the full frequenqr range. 

Insertion Loss - 3 dB <1 GHz. 

LISN (OPT. 16) 

Facilitates conducted emissions. 

Frequency Range - 9 kHz to 100 MHz. 

TRANSIENT LIMITER (OPT. 16) 

Use with LISN to prevent inadvertent damage 
to spectrum analyzer. 

ANTENNAS (OPT. 11) 

Only two antennas required to cover the entire 
EC/FCC 1 GHz radiated measurement range. 
Biconical - Useable from 20 MHz to 
300 MHz. 

Log Periodic - Useable from 200 MHz to 1 GHz. 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



27120B EMI MEASUREMENT STSTEM 
Includes: 27120A System Manual and individual 
component instruments manuals. 

27120B STSTEM OPTIONS 

Opt. 05 - Add 2707 External Tracking Generator. 

Useable for site attenuation, filter design and 

evaluation. 

Frequency Range: 100 kHz to 1.8 GHz. 

Output Level: -48 to 0 dBm. 

Opt. 10 - Add television demodulation. Useful for 
signal identification, includes broadcast (AM) and 
satellite (FM) demodulation. 

Opt. 11 - Add antennas, tripod and cable when sys- 
tem used for radiated measurements. 



Opt. 16 - Add LISN and Transient Limiter when sys- 
tem used for conducted measurements. 

Opt. 17 - Add 2706 RF Preselector. 

INTERNATIONAL POWER PLUGS 
Opt. A1 - Universal Euro 220 V, 50 Hz. 

Opt. A2 - UK 240 V, 50 Hz. 

Opt. A3 - Australian 240 V, 50 Hz. 

Opt. A4 - North American 240 V, 60 Hz. 

Opt. A5 - Switzerland 220 V, 50 Hz. 

See page 619 for description. 

EMI MEASUREMENT SOFTWARE 

EMC120 Software. 



Includes: Instruction manual and four 3.5 in. 
floppy disks. 

EMC120U SOFTWARE UPGRADE PACKAGE 

Upgrades S26EM12 Software to EMC120 Software. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

C€ 

ISO 9001 

Tektronix measurement products are manufactured 
in ISO registered facilities. 



www.tektronix.com/Measurement/commtest/ 



EMI/RFI SOLUTIONS 263 







Features - Benefits Applications 



Part of Automated Measurement 
System Using Tektronix EMC120 
EMI Software 

9 kHz to 1800 MHz Overall Range 
(Bypass Mode) 

Continuous Bandpass Filtering from 
9 kHz to 1800 MHz in Eight 
Selectable Bands 

Attaches to the Tektronix 271 X 
Spectrum Analyzers to Form 
Integrated Unit 



EMC Precompliance Measurements 

Distortion-free Measurements in 
High Ambient Environments 

Manual or GPIB Control 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 



C€ 

ISO 9001 

Tektronix measurement 
products are manufactured in 
ISO registered facilities. 




Product(s) complies with IEEE 
Standard 488.2-1987, 
and with Tektronix Standard 
Codes and Formats. 



2706 Preselector 

The 2706 Stepping RF Preselector facilitates dis- 
tortion-free measurements in the presence of 
large signals at the spectrum analyzer input. If 
total signal power at the first mixer stage of the 
spectrum analyzer exceeds the 1 dB compression 
point, inaccurate amplitude measurements and 
spurious intermodulation products can result. 
The 2706 Preselector enables the spectrum ana- 
lyzer user to make accurate measurements over a 
wider range of signal environments by: 



► Significantly attenuating undesired out-of- 
band signals 

► Reducing energy from high amplitude, short 
duration pulses 

► Minimizing the total number of individual 
signals present at the analyzer input 

Use of commercial RF preselectors has been lim- 
ited because of high costs. Now Tektronix offers 
an affordable and cost-effective solution for pre- 
certification testing. 



Ordering Information 



For price information: 

Outside the U.S. contact your local Tektronix representative, 

2706 

Stepping RF Preselector. 

Includes: 

Power Cord (U.S. 115 V, 60 Hz), Operator's Manual. 

271 X Spectrum Analyzer Mounting Hardware and RF 
Interconnect Cable - Order 118-8800-00. 

MEASUREMENT SERVICE OPTIONS 

Opt. R3 - Repair warranty extended to cover three years. 

SOFTWARE 

See page 262 for complete description. 



inside the U.S. see the price list in the back of this catalog. 

Commercial EMI Test Software - 

Order EMC120. 

INTERNATIONAL POWER PLUGS 
Opt. A1 - Universal Euro 220 V, 50 Hz. 

Opt. A2 - United Kingdom 240 V, 50 Hz. 

Opt. A3 - Australian 240 V, 50 Hz. 

Opt. A4 - North American 240 V, 60 Hz. 

Opt. AS - Switzerland 220 V, 50 Hz. 

See page 619 for description. 



264 E M I / R F 



SOLUTIONS 



www.tektronix.com/Measurement/commtest/ 







EMC Ancillary Devices 



EMC ANCILLARY DEVICES 

► Active Loop Antenna 

► Adjustable-length Dipoles 

► Biconical Antenna 

► Log-periodic Antenna 

► RF Near-field Probe Set 

► LISN 

► Transient Limiter 

► 10 m Low-loss Coaxial Cable 

► Adjustable Tripod 

Sensors or transducers are required for 
EMI signal reception. The sensor picks 
up the EMI signal and couples it to the 
spectrum analyzer. The spectrum ana- 
lyzer then displays the EMI signal as a 
plot of amplitude (vertically) versus fre- 
quency (horizontally). 




The type of sensor needed depends on 
the test standard and the nature of the 
test (radiated or conducted electric field, 
or radiated magnetic field). For radiated 
electric (E) field tests, a biconical, log 
periodic, or dipole antenna may be used. 
Electrostatically shielded loop antennas 
are used for magnetic (H) field tests. 

The specific transducer type required 
also depends on the test standard and 
frequency range. Tektronix has avail- 
able a line of antennas and other sen- 
sors, as shown in the figure at left. 

For conducted measurement, Tektronix 
offers a Line Impedance Stabilization 
Network (LISN). It is inserted between 
the AC power source and the EUT. 
Outputs on the LISN couple the EMI 
emitted by the EUT to the spectrum 
analyzer’s input. 

Our complete line of ancillary devices is 
listed in the ordering information below. 



Ordering Information 



For price information: Outside the U.S. contact 3 

LOOP ANTENNA 

9 kHz to 30 MHz. Order No. 119-4144-00. 

Application Information: Radiated H-field 
(magnetic) emissions. 

ADJUSTABLE-LENGTH DIPOLES 

28 MHz to 1 GHz. Order No. 119-4145-00. 
Application Information: Radiated E-field emis- 
sions/CATV leakage. Ideal for EMI testing and site 
attenuation measurements. Includes four baluns. 

BICONICAL ANTENNA 

30 MHz to 300 MHz. Order No. 119-4148-00. 
Application Information: Radiated E-field 
emissions. Broadband frequency capability elimi- 
nates need for band switching, element extension 
or external tuning. 

LOG-PERIODIC ANTENNA 

200 MHz to 1 GHz. Order No. 119-4142-00. 
Application Information: Radiated E-field (electric) 
emissions. Linearly polarized design permits separate 
measurement of horizontal and vertical fields. 
Broadband frequency. 



• local Tektronix representative, inside the U.S. see 

RF PROBE SET 

9 kHz to 1.8 GHz. Order No. 119-4146-00. 

Application Information: Locates RF "Hot Spots." 
Useful in diagnostic testing. Includes five probes 

(3 H-field, 2 E-field) plus extension. 

LISN 

10 kHz to 100 MHz. Order No. 119-4147-02. 
Application Information: Facilitates measurement 
of conducted emissions on power line from equip- 
ment under test. Filters undesired signals imported 
on mains supply. 

TRANSIENT LIMITER 

9 kHz to 100 MHz. Order No. 011-0164-00. 

Application Information: Use with LISN to prevent 
Inadvertent damage to spectrum analyzer input. 

10 M COAXIAL CABLE 

Order No. 012-1291-00. 

Application Information: Couples antenna to 
spectrum analyzer (male fittings). 

ADJUSTABLE TRIPOD 

Order No. 016-1102-00. 

Application Information: Mounting for all above 
antennas. Wooden frame reduces field disturbance. 



the price list in the back of this catalog. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 



EMI/RFI SOLUTIONS 



www.tektronix.com/Measurement/commtest/ 



265 




Wireless Communication Test Sets 



Contents 



M366plus 267 

MCGS 269 

CMD80 271 

CTRC02 274 

CMD53 277 

CMD55 277 

CTS55 280 

CMD57 281 

CMU 283 

UPD 05 285 

UPL06 286 

UPL66 286 

UPL16 288 



SIGNALING 

Radio test sets, covering major national and international standards, including 
CDMA, GSM, DCS 1800, PCS 1900 and AMPS are described here. 

In addition to the conventional RF and AF measuring facilities, many units also 
include special signaling capabilities. Testers with signaling simulate the base sta- 
tion and perform all signaling measurements to PTT regulations, in addition to all 
conventional radio measurements. For large cellular-radio networks, they also pro- 
vide base-station testing, including signaling. 

Integration of a signaling unit into the radio tester ensures fast data exchange 
between the control units, thus creating the prerequisites for real-time measure- 
ments under practical conditions. 

If in-depth spectral analysis is required, including modulation without signaling, 
refer to the Spectrum Analyzers section. In particular, see information on the 
FSEA Series, R3465, R3463, and R3263. 

► CDMA Mobile Unit Test CMD80 

► CDMA Base Station Test R3465/R3463 CDMA 

► GSM Mobile Unit Test CRTC02, CMD55, CMD53, CTS55 

► GSM Base Station Test CMD57, CMD59 



WIRELESS COMMUNICATION TEST SETS 



266 



www.tektronix.com/Measurement/commtest/ 






Quality of Service Analyzer for 



GSM Networks 

New M366PLUS 




Features - Benefits Applications 



Quality of Service, O&M and 
Network Optimization for GSM900, 
DCS1800, Dual Band and for 
PCS 1900 

Voice Quality Measurements 
Cellular Data and Fax Quality Test 
SMS Verification 



Automatic Generation of Calls from 
a Cellular Phone to a Fixed or 
Cellular Phone 

Simultaneous Measurements on up 
to 4 Different Networks 

Run-Time Display of Results on 
Digital Maps 

Post-processing of Data Obtained 
During Measurement Campaigns 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1 - 503 - 627 - 1916 , 
inside the U.S. call: 
1 - 800 - 426 - 2200 . 



C€ 



MEASURING QUALITY FROM THE 
SUBSCRIBER'S POINT OF VIEW 

Nearly 200 cellular operators worldwide com- 
pete everyday to provide the best quality and, 
at the same time, increase their market penetra- 
tion - as new ones are arriving. After the first 
battle of price rates, they have now understood 
that quality is the key to success: not only 
voice quality, but quality in all services which 
can be provided. 

The M366plus System now provides objective 
measures of Quality even more accurately - not 
only voice quality - everywhere, all the time. 

OPTIMIZING THE "MOBILE" NETWORK 

A cellular network is a “mobile” network not 
only because of the mobility of their customers, 
but also because it is never stationary like a 
fixed one is: new BTSs are deployed, frequency 
plans vary, in other words the network is always 
being optimized. 

The M366plus System is the best companion for 
this job. 

By collecting protocol information and significant 
events, and by means of its powerful post-analy- 
sis tools, the M366plus identifies critical zones 
and highlights the reasons for the problems. 



QOS: NOT ONLY VOICE, BUT ALSO DATA, FAX 
AND SMS 

With the M366plus System it is possible to 
objectively measure not only the quality of voice 
service, but also of SMS, data and fax transmis- 
sion over a cellular network. 

QOS: THE ULTIMATE APPROACH 

Although “Quality is not a matter of opinion,” 
each of us has a different ear and method of 
judgment. This is why one feels more comfort- 
able when he or she can personally listen on the 
receiving end of the communication channel and 
scribble down his or her own MOS. But in the 
M366plus System we have gone one step further: 
we have put together two methods in a single 
system, so that the accuracy, the simplicity and 
the unquestionable precision of our experienced 
technology, based on tbe measurement of impair- 
ment factors (clipping, impulsive noise, psopho- 
metric noise, loudness rating and echo), can be 
combined with the immediateness and confi- 
dence that arises from the automated measure- 
ments of real speech samples. 

The M366PLUS System 

The M366plus System has different components: 
each of them is flexible, configurable and powerful. 



www.tektronix.com/Measurement/commtest/ 



WIRELESS COMMUNICATION TEST SETS 267 





Quality of Service Analyzer for GSM Networks 

NEW M366PLUS 



THE BASE STATION 

The M366plus Base Station is the 
fixed node of the M366plus System. It 
is configurable with up to 4 interfaces 
and DSP measurement boards, emu- 
lating SPSTN-interfaces, provided 
with a local PC controller, and it per- 
forms all the operations required from 
its side: originating and receiving 
voice, data and fax calls, measuring 
Quality, storing data. 

THE MOBILE STATION 

The new generation of M366plus 
Mobile Station boasts a remarkably 
increased capacity of up to 4 test 
phones in any combination of GSM 
900, 1800, dual band and PCS 1900. 

Also provided with the local PC, the 
Mobile Station also features all the new 
powerful quality measurements and 
protocol analysis capabilities. 

THE POST PROCESSING SYSTEM 

In some cases, the M366plus 
Measurement Units can collect huge 
amounts of data and information. In 




order to quickly and effectively focus 
the data of interest, Tektronix offers a 
powerful tool of analysis: M366 REPORT. 

M366PLUS REPORT 

REPORT is the software tool used for 
storing, organizing and analyzing the 
information collected by the measure- 
ment units. 

REPORT can give the user all the 
required views on single or multiple 
sessions compare networks, to filter the 
data in any combination, and to gener- 
ate all sorts of REPORTS, of course, also 
in graphical form. 




The level of detail can be as specific as 
a single event occurring during one of 
the calls. 

This information is fully exploited by 
M366plus REPORT, which, utilizing 
MAPINFO-based software, allows view- 
ing of measurement information on dig- 
ital geographic maps. 

The M366plus System offers two archi- 
tectures for the post-processing envi- 
ronment, which both support the same 
REPORT application. 

► Standalone based on MS-ACCESS 

► Client-server based on ORACLE 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the hack of this catalog. 



BASE STATION 

7KM366-BS - M366plus/GSM Basestation Platform, 
Includes 2 interfaces to access a PSTN network, 
removable notebook, DSP board, power supply and 
AC/DC converter. 

7KM366-MT - M366plus/GSM PSTN Interface 
Board. Extends the Basestation with 2 interfaces to 
access a PSTN network. 

7KM366-DSP - M366plus/GSM DSP Board. 
7KM366-BS-SW-R50 - M366plus Basestation 
Software Release 5.0. Software license for one 
Basestation, media and manual. 

MOBILESTATION (2 INTERFACES) 
7KM366-MS-900 - M366plus/GSM Mobilestation 
Platform, Includes 1 interfaces to access a GSM 900 
network, removable notebook, DSP board, power 
supply, AC/DC converter and battery backup unit. 
Supports Max. 2 interfaces. 

7KM366-MR-900 - M366plus/GSM Radio interface 
Board to extend the Mobile Station with a second 
interface to access a GSM 900 network (Mobile 
(GSM 900) included). 

7KM366-MR-SAG - M366pius/GSM Radio 
Interface Board to extend the Mobile Station with a 
second interface to connect a SAGEM Mobile Phone 
(Mobile not included). 

7KM366-DCR - Remote Control Unit for 
Mobilestation. For starting, pausing, stopping a test 
session. For using inside the testcar. 

7KM366-GPS - M366pius/GSM GSP Board, includ- 
ing antenna. 



7KM366-MS-SW-R50 - M366plus/GSM 
Mobilestation Softw. Rel. 5.0. Software base license 
for one Mobilestation, media and manual. 

MOBILE STATION (4 INTERFACES) 
7KM366-VMS - M366plus Mobilestation for 4 
interfaces, Incl. removable notebook, one controller 
board with DSP processor (Mobile not included), 
power supply (12 VDC), battery backup unit, AC/DC 
converter. 

7KM366-VMR - Mobile controlboard with DSP 
processor (only for 7KM366-VMS). Interface board 
for one mobile (Mobile not included). 
7KM366-VGPS - M366plus/GSM GPS board. 
Including antenna. 

7KM366-VMS-SW-R50 - M366plus Mobilestation 
Softw. Rel. 5.0. Software base license for one 
Mobilestation, media and manual. 
7KM366-VOT35-D - SAGEM Mobile for GSM 1800 
network. Antenna not Included. 
7KM366-VOT35-D-A - Antenna kit for SAGEM 
GSM 1800 mobile. 

7KM366-VOT35-G - SAGEM Mobile for GSM 900 
Network. Antenna not included. 
7KM366-VOT35-G-A - Antenna Kit for SAGEM 
GSM 900 Mobile. 

7KM366-VOT35-P - SAGEM Mobile For GSM 1900 
network. Antenna not included. 
7KM366-VOT35-P-A - Antenna Kit for SAGEM 
GSM 1900 Mobile. 



7KM366-VOT75-M - SAGEM OT75 Dualband 
GSM900,1800 Mobile. Supports EFR. Includes 220 V 
battery charger, 2 rechargeable batteries, user 
manuals. 

7KM366-VOT35-M-A - Antenna Kit for SAGEM 
Dualband Mobile. 

POST-PROCESSING 

7KM366-PC - Desktop PC, Pentium 400 MHz, 

128 MB RAM, 9 GB HD, 17 in. color monitor, internal 
modem, Ethernet LAN communication boari CD-R 
unit, Windows NT4.0 in English. Optional. 
7KIVI366-PP-CSW-R50 - Client Software of Post- 
processing tool for data analysis, report generation 
and mapping of measurements on geographical 
maps based on Oracle. License for one client in a 
client-server architecture. Incl. also 1 MAPINFO run- 
time license. 

7KM366-PP-SSW-R50 - Server Software of Post- 
processing tool for data analysis, report generation 
and mapping of measurements on geographical 
maps based on Oracle. License for server In a client- 
server architecture. 

7KM366-PP-SW-R50 - Post-processIng tool for 
data analysis, report generation and mapping of 
measurements on geographical maps based on MS- 
Access. Incl. MAPINFO runtime license. Software 
license for one stand alone version. 

TRAINING 

7KM366-Traming - M366plus/GSM Training. Price 
Is for three days/per person. Training at the customer 
site on request. 



268 WIRELESS COMMUNICATION TEST SETS 



www.tektronix.com/Measurement/commtest/ 






Mobile Call Generation System 



New MCGS 




Features - Benefits 



Air Interface Test System for 
GSM900, DCS 1800, PCS 1900 and 
Dual Band Networks 

Generating End-to-End Traffic 

Stimulates GSM Mobile Networks 
and Tests All the Components 
(MSC, BSC, BTS) 

Easy Expandable and Automatic 
Recognition of System 
Configuration 



Applications 



Graphical and Flexible Call and 
Traffic Configuration 

Powerful Analysis Including 
Protocol Decoding 

Ideal Product for Load Testing, 
Automatic Sen/ice Testing, Billing 
Verification and Roaming Tests 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1 - 503 - 627 - 1916 , 
inside the U.S. call: 
1 - 800 - 426 - 2200 . 

C€ 



Test of GSM Network Components 

Controlled traffic is one of the most recognized 
ways to test the operation of telecommunication 
systems. 

Tests are accomplished by emulating real users 
of the services, in all GSM variants (GSM900, 
DCS1800, PCS1900 and Dual Band ER/EFR). 



Use of MCGS 

With tlie MCGS, GSM network equipment (BTS, 
BSC, MSC) can be stimulated and tested by 
means of special call patterns which can be 
defined according to the specific testing needs. 

IN THE TEST PLANT 

The MCGS is particularly useful where several 
pieces of equipment are being integrated and 
tested before being put into service. 

By using the MCGS. you can: 

► Trace and analyze the correct execution of 
any single GSM procedure 

► Check the performance of the network in 
stress conditions 

► Find out the reason of the faults 



IN THE OPERATION PHASE 

The MCGS is very useful for discovering faults 
which remained inside the software even after the 
in-house testing or which are due to specific situ- 
ations that cannot be reproduced in a Test Plant. 

It is also useful to verify quickly and effectively 
that everything is correctly working after net- 
work re-configuration or software upgrades. 

Product Description 

The automatic and controlled traffic generation 
at the GSM air interface (Um) is the main func- 
tion of the MCGS. 

MOC and MTC (Mobile Originated and Mobile 
Terminated Calls) are generated in order to emu- 
late any kind of traffic scenario according to the 
schedules and patterns defined by the user. 

The call progression is monitored for each test 
call. 

Speech continuity checks and speech quality 
measurements (on the Traffic Channel) are made 
on the speech calls. 

The GSM layer 2, 3 messages can be traced. 



www.tektronix.com/Measurement/commtest/ 



WIRELESS COMMUNICATION TEST SETS 269 





Mobile Call Generation System 

NEW MCGS 




The users’ mobility is emulated by forc- 
ing lock and handovers. 

GSM Service Emulation 

All the services commonly used by 
the GSM customers can be emulated, 
for example: 

► Standard speech calls 

► Data calls, SMS 

► Phase 2 supplementary services 
(call forv^arding, call hold, 3-party 
calls, etc.) 

Analysis of test results 

The ability to quickly focus on the data 
of interest is one of the most important 
features of a traffic generator and the 




MCGS provides an analysis tool specifi- 
cally designed to quickly focus on 
important data. 

Powerful filtering utilities, summary 
and detailed reporting, fast navigation 
in the “ocean of data” are available. 

The MCGS features strong capabilities 
in the area of fault analysis. More than 
200 fault causes are recognized auto- 
matically and reported by the MCGS in 
several effective ways. 



Flexible Traffic Scenario 
Configuration 

You can take advantage of a graphical 
editor to define any single step and tim- 
ing of any test call. Any possible 
sequence of keystroke selection by a 
GSM customer can be reproduced. 

Traffic scenarios are easily configured 
by grouping different kinds of user- 
defined test calls and by associating 
them to the MCGS telephone interfaces. 

System Architecture 

The MCGS is a modular, open and dis- 
tributed system, based on a Windows 
NT Workstation connected, by means of 
an Ethernet LAN, to a user-definable 
number of Test Control Boards that can 
be hosted both in rack-mounted and in 
transportable platforms. 

The Test Control Boards interface the 
Control Unit and the GSM test or stan- 
dard mobiles that actually access the 
GSM network. 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



RACK PLATFORM 

7KM410-Base - MCGS Basic rack set. Includes 
19 in. rack unit (12 slots), 1 radio interface board 
with Ethernet/Lan interface and a branching unit for 
12 mobile phones. 

7KM410-CONTRL - Radio interface board to con- 
trol one test phone. Test phone not included. 
Occupies one slot. 

7KM410-SPLITTER-2 - Splitter. Used for a wired 
connection of the RF output from an MCGS rack to 
2 separate BTS, or for combining 2 RF outputs from 
2 racks into one output to one BTS. Includes two 
2 m coax cables. 

7KM410-SPLITTER-4 - Splitter. Used for a wired 
connection of the RF output from an MCGS rack to 
4 separate BTS, or for combining 4 RF outputs from 
4 racks into one output to one BTS. Includes two 
2 m coax cables. 

7KM410-KIT - Accessories for a MCGS rack. 
Includes: one 20 dB attenuator, 1 antenna; 1 headset 
with mouthpiece. One compulsory for each rack unit. 
7KM410-FP - Filler panel for the empty slots. To be 
ordered according to the following rule: number of 
FP = 12 - number of radio interface boards. 
7KM410-CABINET - 19 in. Cabinet. Can house up to 
2 MCGS racks with telephone trays and AC/DC con- 
verters; Includes pre-arranged cabling and fuse block. 
7KM410-ACDC - AC/DC Converter 220 V-48 V, 

200 W. Power supply for one MCGS cabinet. 
7KM4I0-PC - Desktop PC, Pentium 400 MHz, 

128 MB RAM, 9 GB HD, 17 in. color monitor, internal 
modem, Ethernet LAN communication board, CD-R 
unit, Windows NT 4.0 In English. Optional. 



TRANSPORTABLE PLATFORM 
7KM410-TRANS-6 - MCGS 19 in. transportable plat- 
form, includes, power unit, AC/DC, dualband antenna, 
radio interface board with Ethemet/Lan interface filler 
panels, cables and accessories. Provides 5 slots for 
additional radio Interface boards (7KM410-CONTRL). 
7KM410-BRAN-T - Branching unit for 6 phones 
and 20 dB attenuators.Optional for the MCGS 
transportable platform. 

7KM410-LPC - PC Notebook with 160 MB RAM, 
Ethernet LAN communication board, Windows NT 
4.0 in English. Includes 20 m LAN Cable. Optional. 

TEST TELEPHONES 

7KM410-OT35-G - SAGEM OT35 Test Telephone for 
GSM900. Includes 220 V battery charger, 2 recharge- 
able batteries, user manuals. 

7KM410-OT35-D - SAGEM OT35 Test Telephone for 
DCS 1800. Includes 220 V battery charger, 2 recharge- 
able batteries, user manuals. 

7KM410-OT35-P - SAGEM OT35 Test Telephone for 
PCS 1900. Includes 220 V battery charger, 2 recharge- 
able batteries, user manuals. 

7KM410-Ons-M - SAGEM OT75 Test Telephone for 
GSM 900, DCS 1800. Supports ER. Includes 220 V bat- 
tery charger, 2 rechargeable batteries, user manuals. 
7KM410-OTXX-X-A - Dual cable for connection of a 
SAGEM telephone, with 90 degr. RF Connector. One 
has to be ordered for each radio interface board 
(MCGS-Control and MCGS-CPU-Control). 
7KM410-OTXX-X-UPG - Kit for upgrading the soft- 
ware of SAGEM mobile from a PC. 



SOFTWARE 

7KM410-SW-V-B-R10 - Base and user license for 
MCGS Application SW - Rel.1.0, in English. First user. 
7KM410-SW-V-B-8-R10 - Base and user license 
for MCGS Application SW - Rel.1.0, In English, from 
2nd-8th user. 

7KM410-SW-V-B-M-R10 - Base and user license 
for MCGS Application SW - Rel.1.0, in English, from 
9th user. 

7KM410-SW-V-12-R10 - Software license for 
MCGS Application SW for the first to 12th Interface. 
7KM410-SW-V-24-R10 - Software license for 
MCGS Application SW for the 13th to 24th interface. 
7KM410-SW-V-M-R10 - Software license for 
MCGS Application SW from the 25th interface. 
7KM410-SW-S-B-R10 - Base license for MCGS 
Voice Quality Measurement SW - Rel.1.0, In English. 
7KM410-SW-B-B-R10 - Base license for MCGS 
Billing Verification SW - Rel.1.0, in English. 

For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

C€ 



270 WIRELESS communication TEST SETS 



www.tektronix.com/Measurement/commtest/ 







Features - Benefits Applications 



Fast Measurement Times CDMA Mobile Phone Testing 

Large LCD Display Enhances the AMPS Mobile Phone Testing 

Friendly User Interface Mobile Phone Testing 

Minimal Coding Required 

Dual-mode CDMA/Analog 
Measurements 

Cellular and PCS Frequencies in a 
Single Test Set 

IS-136 Support 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 



C€ 




Product(s) complies with IEEE 
Standard 488.2-1987, RS-232-C, 
and with Tektronix Standard 
Codes and Formats. 



Tektronix 

/ 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



CMD 80 Digital Radio 
Communication Tester 

The CMD80 is a multi-protocol mobile handset 
tester that is optimized for manufacturing test 
environments, attacking those areas that are 
most significant to a handset manufacturer; min- 
imized capital expenditure, maximized 
speed/throughput and reduced test design time. 

To reduce capital expenditure, the CMD80 
allows the handset manufacturer to create uni- 
versal test lines. The CMD80 supports all of the 
following network types without the use of 
external modules: 

► CDMA 

► IS-136 (NEW) 

► AMPS 

► NAMPS 

► ETACS 

► NTACS 

► JTACS 

By creating universal test lines, the handset 
manufacturer reduces the amount spent on 
spares, training, manufacturing space and labor. 

The CMD80 provides maximum speed and 
throughput for the handset manufacturer. In 
benchmarks and in field trials, the CMD80 has 
been demonstrated to be as much as 20% faster 
than major competitors. This allows the manu- 



facturer to produce more phones per dollar of 
labor and capital expense. 

The CMD80 also uses the concept of test “envi- 
ronments” that allow the CMD80 to execute tests 
using l/6th of the code required for most testers. 

These environments allow the test programmer 
to define standard test parameter defaults that 
are used until they are redefined. 

By using the environment technique, the test pro- 
grammer is not required to repeatedly reissue a 
laundry list of setup commands each time a test 
needs to be executed. This reduces the amount of 
test time overhead, the time required to construct 
test programs, and the effort required to debug 
and support test programs. All of this adds up to 
more reliable testing for less investment. 

The CMD80 Digital Radio Communication Tester 
is a compact tester for CDMA, AMPS, TDMA 
and other mobiles. The mobile RF parameters 
are verified under similar conditions as found in 
a real network; i.e., the tester simulates a base 
station, makes a call to the mobile, and performs 
the measurements without any special test 
modes in the device-under-test. In the CDMA 
mode the CMD80 measures several key IS 95 
parameters using IS 98 methods: 

► FER service option 2 

► Frame errors 

► Waveform quality p 



www.tektronix.com/Measuremeiit/commtest/ 



WIRELESS COMMUNICATION TEST SETS 271 






Communications Test Sets 

CMD80 WITH IS-136 SUPPORT 



► Error vector magnitude 

► Phase error 

► Magnitude error 

► Carrier feedthrough 

► Frequency accuracy 

► Power measiuements 

► Base station signaling for mobile 
testing 

SIMULATION OF A BASE STATION 

The CDM 80 simulates a base station 
and provides all the signaling necessary 
to hold up a call: 

► Synchronization of mobile 

► Registration of mobile 

► Incoming/outgoing calls 

► Handoffs 

During the call, the tester verifies the RF 
performance and checks the correct 
operation of the basic signaling features. 

The CMD 80 does not rely on any spe- 
cial test modes in the mobile station 
and performs the measurements under 
conditions almost identical to those in 
the real network. A voice loop-back 
allows quick verification of mobile per- 
formance as it is perceived by tlie user. 

EASY TO USE 

The CMD 80 is extremely user friendly 
and requires little detailed network 
knowledge. The large high-contrast liq- 
uid crystal display provides softkeys on 
both sides to allow convenient call-up 
of test routines under menu control. 

Easily, the user can switch to a menu 
and change the current settings of sig- 
naling and measurement parameters. 
The user is guided through the menus 
by explanatory text and may always 
return to the default setting with a push 
of a button. 

FAST MEASUREMENTS 

State-of-the-art digital technology leads 
to quick and efficient measurements for 
rho and power. In remote control mode 
via IEEE bus, the instrument is excep- 
tionally fast and yields high throughput 
in production. 



TEST CAPABILITIES 

All essential characteristics of a mobile 
station can be tested with high accura- 
cy. The CMD 80 not only verifies the RF 
performance of a mobile but, in addi- 
tion, checks software features of the 
mobile which are important for the cor- 
rect operation of the network. In many 
cases, this avoids the need for expen- 
sive custom test beds in development 
and QA. 

HIGH FLEXIBILITY 

Almost every signaling and measure- 
ment parameter can be modified by the 
user in the configuration menus, either 
dynamically during a test or in advance. 
Even the tolerances for pass/fail verdicts 
can be changed to match the require- 
ments of the application. 

DC MEASUREMENTS 

The DC ammeter/voltmeter designed for 
pulsed signals allows correct measure- 
ment of the power consumption of the 
mobile station. 



Characteristics 



SIGNAL GENERATOR 
CDMA Frequency - 

Range: 

PCS U.S.: 1930 to 1990 MHz. 
PCS Korea: 1805 to 1870 MHz. 
U.S. Cellular: 869 to 894 MHz. 
Resolution: 1 Hz. 

Error: Same as timebase. 
Output Level - 
RF/ln/Out: -20 to -132 dBm. 

RF Out2:Oto-113 dBm. 

Resolution: 0.1 dB. 

Error (RF In/Out): <1.0 dB. 

Modulation - 

Carrier Suppression: -30 dBc. 

ANALYZER 
CDMA Frequency - 

Range: 

PCS U.S.: 1850 to 1910 MHz. 

PCS Korea: 1715 to 1780 MHz. 
U.S. Cellular: 824 to 849 MHz. 
Japan Cellular: 887 to 925 MHz. 
Resolution: 1 Hz. 

Error: Same as time base. 



Power Measurement - 

Reference level range: 

RF In/Out (full scale): +41 to -28 dBm. 

RF In2 (full scale): 0 to -69 dBm. 
Measurement error: 

Absolute: <1.5 dBm. 

Relative: <0.3 dB (reference level to -30 dB). 
Typical: <0.5 dB. 

Dynamic Range: 50 dB below reference level. 
Modulation Analyzer - 
p error (25 ±10®C): 0.003 (for p 0.9 to 1). 
Frequency Measurement Range: ±3 kHz. 
Frequency Measurement Error: Reference 
±30 Hz. 

Timing Measurement Error: ±60 ns. 

Timebase - 

Standard: 

Nominal frequency: 10 MHz. 

Frequency drift (0 to 35®C): <1.5 x 10'®. 
Frequency aging: <0.5 x 10"® /year 
(at 35®C). 

OCXO Reference Oscillator (Opt CMD Bl): 
Nominal frequency: 10 MHz. 

Frequency drift (0 to 45®C): <1.1 x 10"^. 
Frequency aging: ^ x 10"^ /yr (<0.5 x 
10"7day after 30 days operation). 

Warm up tlme(at 25°C): Approx. 5 minutes. 

REFERENCE FREQUENCY 
INPUTS/OUTPUTS 
Synchronization Input - 

Frequency: ], 2, 5, or 10 MHz. 

Impedance: Approx. 100 Q. 

Level: 0 dBm to TTL. 

Synchronization Output - 
Frequency: 10 MHz or frequency at 
synchronization input. 

HL, Rout = 50 a. 

AWGN (ADDITIVE WHITE GAUSSIAN 

NOISE) GENERATOR 

Equivalent Noise Bandwidth - 1.8 MHz 

typical. 

Gain Adjustment Range - -20 to +6 dB of 

forward channel power. 

DC VOLTAGE MEASUREMENTS 
Range - 0 to ±30 V. 

Resolution - 10 mV. 

Error - 2% + resolution. 



272 WIRELESS COMMUNICATION TEST SETS 



www.tektronix.com/Measurenient/commtest/ 





Communications Test Sets 

CIVID80 WITH IS-136 SUPPORT 



DC CURRENT MEASUREMENT 
Mode - Averaging, + peak, - peak. 

Range - 0 to ±10 A. 

Common-mode Rejection - ±30 V. 

Shunt Resistance - 50 mQ. 

Resolution for Averaging - 1 mA/10 mA. 
Resolution for Peak - 10 mA. 

Residual Indices - <10 mA. 

Error - <2% + resolution + residual 
indication. 



ENVIRONMENTAL 
Temperature Range - 

Operating: 0 to +45° C, to DIN lEC 68-2-1/2. 
Nonoperating: -40° to +60° C. 
Electromagnetic Compatibility - 
Corresponds to the requirements of European 
EMC directive (89/336/EEC). 

POWER SUPPLY 

Line Voltage - 110 to 120 V AC ±10o/o, 200 to 
240 VAC ±10%. 



Line Frequency - 50 to 400 Hz ±5%. 
Electrical Safety - VDE 0411, class 1, 
lEC 1010-1, EN6101 part 1. 

Physical Characteristics 

Dimensions mm in. 



Height 


192 


7.6 


Width 


435 


17.1 


Depth 


363 


14.3 


Weight 


.k* 


lb. 


Without options 


= 15 


=33 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the hack of this catalog. 



CMD80 

Digital Radiocommunication Tester. 

Includes - Power Cord, Manual. 

Standard - CDMA Support, 800 MHz (U.S. Cellular), 
Memory Card Interface. 

Opt. B1 - OCXO Reference Oscillator. Ensures high 
absolute accuracy, minimum temperature-dependent 
drift, and especially high long-term stability. 

Opt. B84 - TDMA Support. 

Opt. B14 - Rate set 2 (13K) Vocoder. 

Opt. CMD-B17IQ - l/Q Outputs. 

Opt. B3 - Reference Frequency Inputs/Outputs. 

Opt. B60 - Adapter for Opt. 861 and 
Opt. 862 (standard). 

Opt. B61 - lEC/IEEE 8us Interface. 

Opt. B62 - Memory Card Interface (standard). 



Opt. B81 - AWGN Generator. Allows testing mobile 
with additional noise (requires Opt. 04 Adapter). 
Opt. K2 - Adds PCS. 

Opt. K1 - Adds Cellular (standard). 

Opt. B82 - AMPS Support. 

Opt. MM 18 - Message Monitor. 

ZZA-94 - ZZA-94 - Rackmount Adapter. 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of Calibration Services. 

Opt. D1 - Cal Data Report. 

Opt. D3 - Test Data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover 
three years. 

ADDITIONAL ACCESSORIES 

MM 18 - Message Monitor. 



For your local Tektronix representative see the list in 
the oack of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 



C€ 




Product(s) complies with IEEE Standard 488.2-1987, 
RS-232-C, and with Tektronix Standard Codes and Formats. 

Tektronix 

/ 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



www.tektronix.com/Measurement/commtest/ 



WIRELESS COMMUNICATION TEST SETS 273 





Communications Test Sets 



CRTC02 




Features - Benefits 



Automatic Measurements and 
Logging Using Supplied Test 
Procedures 

Built-in TTL Inputs/Outputs in the 
Transmit and Receive Path 

Fast and Reliable Testing of 
Modules and Complete Mobile 
Stations 

Automatic Test Routines 
Simulate Base Station with Call 
Setup, Data Transfer and All 
Signaling Procedures Between 
CRTC02 and the Station-Under-Test 

Log All Signaling Activities in OSI 
Layers 1, 2 and 3 for Protocol 
Analysis; Mnemonic Display of 
Message Content for Protocol 
Troubleshooting 

Check Error-correction Facilities of 
the Mobile Station by Implanting 
Errors in the Data Stream 



Applications 



Measurements on GMSK-modulat- 
ed RF Signals and Receiver Testing 

Testing for Compliance with GSM, 
DCS 1800 and PCS 1900 
Recommendations 

Simple Generation of Customized 
Test Procedures 
Research and Development 
Quality Assurance 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 



C€ 




Product(s) complies with 
IEEE Standard 488.2. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



Transmitter Measurements: 

-Power Ramp and Phase 
Trajectory 
-Burst Delay 
-Frequency Error 

Receiver Measurements: 

-Bit Error Rate in Real Time 
- Receiver Sensitivity 

Speech Coder and Decoder Tests 

Numerical and Graphical Output of 
Results 

I EC/IEEE Bus Interface (Opt. 04) 



CRTC02 Radiocommunications 
Test Set 

The CRTC02 provides signal generation, signal 
measurement and user-friendly soft^vare. They 
are extremely powerful test sets, providing all 
simulation and analysis capabilities - from 
measurement of GSM/DCS 1800/PCS 1900- 



specific signals to detailed checking for hidden 
errors in signaling. 

SIGNALING 

The CRTC02 accurately simulates the functions 
of an ideal base station. For troubleshooting on 
the unit-under-test, the signaling parameters can 
also be varied. 



274 WIRELESS communication TEST SETS 



www.tektronix.com/Measurement/comintest/ 




Communications Test Sets 

CRTC02 



All layer 1 channel coding, as well as 
layer 2 signaling, is automatically per- 
formed in real time. The layer 3 signal- 
ing sequence is defined by special test 
programs. 

PROTOCOL ANALYSIS 

Every transmitted or received layer 2 or 
layer 3 message, or even the bits of a 
burst, are marked with a frame number 
and recorded in the log memory. 
Depending upon whether everything is 
logged or just selected logical channels, 
the log can cover a inter\^al between ten 
seconds and 15 minutes. The logged 
messages are displayed in mnemonic 
form on the screen, using the same 
basic mask as the message editor. 

BURST ANALYSIS 

After data have been logged, power 
ramping as well as phase and frequency 
errors are calculated and displayed as a 
whole. Detailed analysis is supported 
by the zoom function. 

To check the timing-advance measure- 
ment function of a mobile station, the 
CRTC02 measures the arrival of the 
burst and monitors the response of the 
mobile station to timing advance com- 
mands in the generator channels. 

To permit synchronization of external 
measuring instruments, a spectrum ana- 
lyzer for example, the CRTC has a trigger 
output for automatically starting meas- 
urement at the beginning of a burst. 

TESTING RECEIVER SENSITIVITY 

In the loop-back mode, bit error rates 
(BER) can be measured in real to test the 
receiver sensitivity of a mobile station. 

The same test can be made on base sta- 
tions by applying a .signal modulated 
with a CCITT test pattern to the 
receiver input. 

ACOUSTIC TESTS 

These tests are supported by the built- 
in speech coder function and the 
Digital Audio Interface (DAI) of the 
mobile .station as defined in 
Recommendation 11.10.III.6.4. 

A serial EMMI is provided for remote 
control of the mobile station. 

AF MEASUREMENTS (OPTION 01) 

A wide range of audio measurements 
can be performed on the AF section of 



the station-under-test. The AF generator 
provides single or double tones. The 
following measurement functions are 
implemented: 

► AF voltmeter with RMS or peak 
weighting 

► Continuously tunable distortion and 
SINAD meter 

► AF frequency counter 

► DC ammeter/ voltmeter 



Characteristics 



ANALOG UNIT 

SIGNAL GENERATOR 
Frequency Range - 

GSM band: 935 to 960 MHz. 

DCS 1800 band: 1805 to 1880 MHz. 

PCS 1900 band: 1930.2 to 1989.8 MHz. 

Hop Size - Any frequency step within GSM, 
DCS 1800, or PCS 1900 bands. 

Frequency Fine Timing - 0 to 60 Hz with 
about 2 Hz resolution. 

Frequency Setting - <500 ps (to within 
<4° of final phase). 

Spurious Phase Modulation - <T RMS, 

<4° peak. 

Frequency Drift - <2 x \0~yX. 

Aging (After 30 Days Operation) - 

<2 X lO-^day. 

Maximum Output Level - 13 dBm. 

Static Attenuation Setting - 0 to 135 dB. 

Resolution: 5 dB. 

Dynamic Attenuation (Electronic) - 0 to 

35 dB. 

Level Error (Dynamic Attenuation 0 dB) - 

<1.5 dB from - 122 to +13 dBm. 

Modulation - GMSK, bit rate 270833 bit/s to 
GSM Rec. 05.04. 

Burst Delay - -4.6 to +4.6 ms, variable in 
0.46 steps. 

ANALYZER 
Frequency Range - 

GSM band: 890 to 915 MHz. 

DCS 1800 band: 1710 to 1785 MHz. 

PCS 1900 band: 1850.2 to 1909.8 MHz. 

Reference Level for Full Dynamic Range 
(Adjustable in 3 dB Steps) - 

RF IN/OUT: 9 to 36 dBm. 

RF IN 2: -21 to +6 dBm. 

Level Error - <2 dB. 

Sampler - Two 12-Bit A/D converters for I and 
Q signals, sampled at 1.083 MHz (4 samples 
per bit). 



SYNCHRONIZATION 

10 MHz output, 10 MHz input/output, 52 MHz 
output, slot sync output. 

INPUTS/OUTPUTS 

Fading Simulator - Two type N connectors, 
50 Q per channel. 

Output Level - 8 to 13 dBm. 

RF IN/OUT and RF IN 2 - N-type female 
connectors, 50 Q. 

Speech Coder Input - 

Full dynamic range: 20 mV to 2 V. 

Rjp: 100 kQ. 

Speech Decoder Output - 

Full dynamic range: 2 V. 

Rout- "^3 n. 

Audio Monitor - Built-in loudspeaker, head- 
phones connector, volume control. 

Modes - Voltmeter, AF generator, speech 
decoder, speech coder. 






m 



DIGITAL UNIT 
Processor - Pentium 233 MHz. 

RAM - 8 MB. 

Hard Disk - 2 GB. 

Floppy Disk Drive - 3.5-in., 1.44 MB. 
Graphics - VGA. 

Interfaces - IEC-625/IEEE 488 bus; RS-232C; 
Centronics; Keyboard connector on front and 
rear panels; CODEC input/output; Control 
interface; DAI/EMMI. 

AF MEASUREMENT UNIT (OPT. B1) 



AF GENERATOR 
Signal Source - 

Single or dual tone: 

Frequency range: 20 Hz to 20 kHz. 

Output level (RMS): 10 pV to 5 V. 

Output impedance: <3 Q. 

AF Voltmeter - 
Modes: RMS, + Peak, - Peak. 

Frequency range: 50 Hz to 20 kHz. 

Level range (RMS): 0.1 mV to 30 V. 

Weighting Filters - 
can filter: To can 0.41. 

Programmable highpass filter: 107 Hz to 
10.6 kHz. 

Programmable lowpass filter: 235 Hz to 21 kHz. 
Programmable notch filter: 100 Hz to 5 kHz 
(notch frequency). 

Distortion and SINAD Meter - 

Fundamental frequency range: 100 Hz to 
5 kHz. 

Measurement range: 0 to 50%, 1 to 50 dB. 
Safety - EN61010-1, IEC61010-1. 



www.tektronix.com/Measurement/commtest/ 



WIRELESS COMMUNICATION TEST SETS 275 




Communications Test Sets 

CRTC02 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



Opt. 2T - Advanced Training. 

Opt. BI/CRTP-Bl- AF Measurement Unit. 

Opt. B2/CRTS-B1 - AF Measurement Unit. 

Opt. B4/CRT-B4 - Half rate/enhanced full rate 
sheet coder. 

Opt. B7/CRTP-B7 - l/Q Inputs/Outputs. 

Opt. B9/CRTP-B9 - 2nd internal pilot synthesizer. 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of Calibration Services. 

Opt. D1 - Cal Data Report. 

Opt. D3 - Test Data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover 
three years. 

SOFTWARE 

GSM Phase 2+ Operation Software - Required 
on the CRTC02 Slave and Master Unit. 

Order CR02P2P. 

One Year Software Upgrade for CR02P2P - 

Required on the CRTC02 Slave and Master Unit. 

Order C2P2PSC. 

Basic Software for Multislot - Transparent data 
services. REQUIRED on master Unit only. REQUIRES 
CRT-K8. Order CR49P2P. 

Channel Coder for 14.4 Kbit - Used to permit 
investigation of the channel encoder software. 

Order CRT-K9. 

Basic Operation Software for Communication 
Between CRTx Master and Slave (DUO) - 

Required on the CRTC02 Master Unit Order CR02DUO. 
One Year Software Upgrade for CR02DUO - 
Required on the CRTC02 Master Unit Order C2DU0SC. 
DUO - Allows the connection of two CRTC02S in 
order to handle multislot applications. Required on 
the CRTC02 Master Unit Order CRT-U5. 
GSM900/1800/1900 Audio Testcases - Section 30. 
Audio Analyzer UPL15 required. Order CRTKAUD. 
One Year Software Upgrade for CRTKAUD - 
Order CRAUDSC. 

Testcases for EGSM and R-GSM (Railway) - 

Order CRTKEGS. 

One Year Software Upgrade for CRTKEGS - 
Order CREGSSC. 

Test SIM Card -Order CRTZ2. 

GSM/DCS 1800 Phase 2 Basic Software - 

Order CR02PH2. 

SMS/TDS Phase 2 Basic Software for 
GSM/DCS 1800 - Order CR48 PH2. 

Ciphering Software - Order CRTS-K1. 

Ciphering Software (A5-2) - Order CRTS K2. 



PCS 1900 Phase II Test Case - Order CRTPK72. 

PCS 1900 Phase II Test Case - Order CRTPK73. 

PCS 1900 Phase II Test Case - Order CRTPK74. 

PCS 1900 Handover Phase II Test Case - 

Order CRTPK75. 

PCS 1900 Supplementary Service Phase II Test 
Case - Order CRTPK78. 

PCS1900 Phase II SMS Test Case - Order CRTPK79 
GSM TDS Phase II Test Case - Order CRTPK5A. 
DCS1800 TDS Phase II Test Case - Order CRTPK6A. 
PCS1900 TDS Phase II Test Case - Order CRTPK7A. 
GSM NTDS Phase II Test Case - Order CRTPK5B. 
DCS1800 NTDS Phase II Test Case - 
Order CRTPK6B. 

PCS 1900 NTDS Phase II Test Case - 

Order CRTPK7B. 

GSM Phase II Bundled Test Case - Order CRTBR19. 
DCS1800 Phase II Bundled Test Case - 

Order CRTBR31. 

PCS 1900 Phase II Bundled Test Case - 

Order CRNATA. 

Half Rate/ Data Channel Coding - Order CRT-K3. 
HSCSD/Multislot Channel Coding - Order CRT-K8. 
NTDS/RLP Basic Software - Order CR28PH2. 
HR/EFR Speech Coder - Order CRT-B4 Hardware 
and CRT-K5 and CRT-K7 Software. 

Multiband Handover - Order CRT-B9 Hardware 
and CRTMKBl Software. 

GSM Phase 2 Test Cases - Order CRTP K52. 

GSM Phase 2 Test Cases - Order CRTP K53. 

GSM Phase 2 Test Cases - Order CRTP K54. 

GSM Handover Test Phase 2 - Order CRTP K55. 
GSM Test Cases Phase 2 - Order CRTP K56. 

GSM Phase 2 Supplementary Service Test 
Case - Order CRTP K58. 

GSM Phase 2 SMS Test Case - Order CRTP K59. 
DCS 1800 Phase 2 Test Case - Order CRTP K62. 
DCS 1800 Phase 2 Test Case - Order CRTP K63. 
DCS 1800 Phase 2 Test Case - Order CRTP K64. 
DCS 1800 Handover Test Phase 2 - 
Order CRTP K65. 

DCS 1800 Test Cases Phase 2 - Order CRTP K66. 
DCS 1800 Supplementary Service Test Case - 

Order CRTP K68. 

DCS 1800 Phase 2 SMS Test Case - 

Order CRTP K69. 



ADDITIONAL ACCESSORIES 
One Year Software Upgrade for: 
CRTPK52 - Order CPK52SC. 
CRTPK53 - Order CPK53SC. 
CRTPK54 - Order CPK54SC. 
CRTPK55 - Order CPK55SC. 
CRTPK56 - Order CPK56SC. 
CRTPK58 - Order CPK58SC. 
CRTPK59 - Order CPK59SC. 
CRTPK5A - Order CPK5ASC. 
CRTPK5B - Order CPK5BSC. 
CRTPK62 - Order CPK62SC. 
CRTPK63 - Order CPK63SC. 
CRTPK64 - Order CPK64SC. 
CRTPK65 - Order CPK65SC. 
CRTPK66 - Order CPK66SC. 
CRTPK68 - Order CPK68SC. 
CRTPK69 - Order CPK69SC. 
CRTPK6A - Order CPK6ASC. 
CRTPK6B - Order CPK6BSC. 
CRTPK72 - Order CPK72SC. 
CRTPK73 - Order CPK73SC. 
CRTPK74 - Order CPK74SC. 
CRTPK75 - Order CPK75SC. 
CRTPK76 - Order CPK76SC. 
CRTPK78 - Order CPK78SC. 
CRTPK79 - Order CPK79SC. 
CRTPK7A - Order CPK7ASC. 
CRTPK7B - Order CPK7BSC. 
CRTKMB1 - Order CRMBISC 
2 GB Hard Drive - Order CRTS-B2. 



For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

C€ 




Product(s) complies with IEEE Standard 488.2. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



276 WIRELESS COMMUNICATION TEST SETS 



www.tektronix.com/Measurement/commtest/ 






Communications Test Sets 

CMD53 • CMD55 




Features - Benefits Applications 



Development & QA 

Production 

Service 



Go/Nogo Test as well as Sen/ice 
Mode for Exact Fault Location 

CMD53 

GSM900, GSM 1800 and GSM 1900 

Testing of Handover From GSM900 
and Back 

Other Features as CMD50 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 



C€ 




Product(s) complies with IEEE 
Standard 488.2-1987, RS-232-C, 
and with Tektronix Standard 
Codes and Formats. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



Meeting the Challenges of 
Modern Communications 

► Go/nogo tests and comprehensive testing of 
mobiles 

► Powerful signaling capabilities 

► Short measurement time ensuring high 
throughput 

► High measurement accuracy 

► Simple interactive operation 

► No specialized GSM knowledge required 

► Service mode for exact fault location 

► Autotest — complete mobile testing at a 
keystroke 

► Very fast remote control operation 

► Compact and lightweight 

► Excellent price/performance ratio 

MANUAL OPERATION PHILOSOPHY 

Research and development engineers have found 
the CMD’s large clear LC display and user inter- 
face with logically structured menus unsur- 
passed when measuring RF parameters. This is 
true both in the manual test mode and in the 
flexible module test with system-specific signal 
generator and burst analyzer. During call setup 
the network and system-specific signaling 
parameters allow the R&D engineers to control 



the influence of signaling parameters on the 
mobil’s behavior in the network. 

USER-DEFINABLE AUTOTEST 

The user-friendly display and operation of the 
CMD is a main requirement when testing manu- 
ally, but for automated testing, the engineer 
wants a quick and easy way to a ready-made 
autotest or he has to create his own test script 
for the specific task to be performed. The CMD 
family of testers offers different ways of creating 
such autotests and test scripts, depending on the 
CMD model and the test requirements. 

FAST lEEE-BUS 

In a production line there are two main factors 
that contribute to high throughput and product 
quality: lEC/IEEE-bus speed and measurement 
repeatability. 

The CMD offers the fastest lEEE-bus operation 
available. With combined measurements and 
measurements like RF peak power which takes 
only milliseconds, time-consuming power level 
adjustments where multiple measurements are 
required are completed in seconds. The level of 
measurement repeatability offered ensures the 
highest possible quality of the end product leav- 
ing the factory. 



www.tektronix.com/Measurement/commtest/ 



WIRELESS COMMUNICATION TEST SETS 277 





Communications Test Sets 

CMD53 • CMD55 



COVERING ANY NEED FOR 
TEST MODES 

Service and repair of digital mobiles 
and cordless phones call for a variety of 
tests, ranging from simple go/nogo tests 
to complete factory-like production 
tests and calibration of the phone. The 
CMD range offers cost-effective solu- 
tions for manual testing, stand-alone 
autotest, as well as remote RS232 oper- 
ation solutions covering any need for 

Tailored to Your Application 



testing. Every CMD comes, of course, 
with the same large display and user 
interface for manual test of phones 
and/or modules and RS232 interface for 
remote operation. 

BASE STATION SURVEY 
MEASUREMENTS 

These are often done on real base sta- 
tions or by using analog signal genera- 
tors with power amplifiers. The CMD is 



able to simulate any GSM base station 
BCCH, including parameters like MCC, 
MNC, NCC, BA list, DTX and DRX 
information. These and the “cell barred” 
feature enable close-to-life conditions 
without having to use a real BTS. 

Safety - UL3111-1, CSAIOIO.I. 



Options 



Name 


Description 


Notes 


Opt. B1 


oao reference oscillator, aging ±1 x 10'^ Ensures high absolute accuracy, minimum 
temperature-dependent drift and especially high long-term stability. Used for measurements 
with exacting requirements on frequency stability. 


Cannot be ordered with Opt. B2 


Opt. B17 


I/Q signals from the CMD modulator and burst trigger signals are provided for 
Rohde&Schwarz Signal Generator SMIQ for GSM-conformity tests under fading conditions. 




Opt B19 


GSM1900 mobile and base station test Provides the capability to test GSM1900 mobiles 
used on the North American market. Includes factory recalibration of unit 


For CMD53, 55 as of Serial No. 837176 


Opt B2 


High-stability OaO, aging 3.5 x 10"®. Oven crystal with highest long-term stability. Ensures 
compliance with tolerances specified by GSM. Used for highly demanding requirements on frequency 
stability to GSM 11.20. 


Cannot be ordered with Opt. B1 


Opt B20 


GSM-specific voltage and current measurement Allows readings to be taken In synchronicity 

with the GSM pulsed mode. 


Comes as standard in all models 
except CMD53 


Opt B3 


Multifrequency reference input/output For synchronizing DUT and measuring instrument 

with Internal or external frequencies. Allows synchronization of CMD to an internal or external frequency 

of 2.048, 10, 13, 26, 39, 52 MHz, or to the GSM bit clock. 




Opt. B30 


High-level RF output/sensith/e RF input In addition to the normal RF I/O the CMD has optionally 
a high-sensitivity input and a high-level output which enable over-the-air tests on modules or 
handhelds by means of couplers like CTD-Z10. 


Comes as standard in all models 
except CMD53 


Opt B4 


Fast power ramp, phase/frequency error & BER measurement Provides fast testing and numeric/graphic 
display of power bursts and phase/frequency error as well as various BER, RBER and FER test routines 
(necessary for Autotest). „ 


Required for options Opt. B41, Opt B42, 
Opt. B43, Opt B44 and Opt K43 


Opt B41 


Includes audio frequency (AF) generator, voltmeter, distortion meter and frequency counter. Allows 
measurements on the audio interface or on modules. Enables frequency measurements up to 
60 MHz which is required for LO alignment 


Requires Opt. B4 


Opt. B42 


High dynamic range burst analyzer. Enhances the dynamic range to more than 72 dB and allows 
the power ramp to be measured in the entire specified GSM, GSM 1800 and GSM 1900 range. 
Determines whether transmitter blanking in inactive time slots is correct 


Requires Opt B4 


Opt. B43 


Carries out GSM measurements of spectrum due to switching and modulation according to the 
GSM, GSM 1800 and GSM 1900 recommendations faster than any spectrum analyzer. 


Requires Opt B4 and Opt B42 


Opt. B44 


Audio multitone option based on DSP techniques. Makes it possible to generate and measure up to 
14 tones in about a second. Useful for loudness rating, frequency response and intermodulation analysis. 


Requires Opt B4 and Opt B41 


Opt B51 


Internal GSM full rate (FR) and enhanced full rate (EFR) speech coder/decoder. This option converts 
digital speech signals into analog signals and vice versa, allowing for separate uplink and 
downlink audio measurements. 


■ 


Opt B6 


Adapters for B6x options. Provides GSM specific signals and trigger signals for CMD52/55/65 on 
the multifunction connector at the front of the instrument. 


Required for options Opt. B61 and Opt B62 


Opt B61 


lEC/IEEE 488-bus interface. Remote control alternative to the RS-232-C interface fitted as standard. 
Used for fast remote control of CMD. 


Requires Opt. B6 


Opt. B62 


Memory card interface. Allows storage of instrument setups and fast and easy upgrade to new 
software features. Highly recommended. 


Requires Opt B6 


Opt K43 


Narrowband spectrum analyzer. This option is used for narrowband spectrum analysis 
(i.e.. adjustments of I/Q modulators). Analysis of constant envelope and burst signals is possible. 


Requires Opt. B4 


Opt. K80 


Frequency extension option. For CMD5x and CMD65. Additional frequency range R-GSM. 


Requires Opt UlO 


Opt U1 


Upgrade to GSM multiband functionality. Allows for GSM dual-band handover with CMD53 and CMD55. 


Some mobiles require Opt U20 to ensure 
correct dual-band handover operation 



278 WIRELESS COMMUNICATION TEST SETS 



www.tektronix.com/Measurement/comintest/ 



Communications Test Sets 

CMD53 • CMD55 



Name 


Description 


Notes 


Opt. UlO 


8 MB memory extension for CPUl or CPU2. This update allows the use of several advanced software 
features such as GSM dual-band handover, fast BER measurement (burst-ty-burst) and R-GSM band. 


Only applicable to older versions of CMD53 
and CMD55 


Opt. Ull 


High-speed processor including 8 MB RAM. Allows for the latest software versions with the 
functionality as mentioned in this data sheet and ensures future updates. 


For older versions of CMD55 only 


Opt. U12 


Modification for fast BER (burst-by-burst) capability. 


For older versions of 55 only 


Opt. U13 


10 dB higher sensivity at RF input/output N connector. RF input level range 
-10 dBm to +37 dBm instead of 0 dBm to +47 dBm. 


Only for GSM signals 


Opt. U18 


Output level of -15 dBm for RF input/output N connector. RF out 2 becomes non-functional, 
RF in/out 6 dB more sensitive (max. +40 dBm). 


Only for GSM signals 


Opt. U19 


GSM 1900 mobile test. Provides the capability to test GSM 1900 mobiles used on the North American 
market Same as CMD-B19 if installation and recalibration can be done at the local R&S service center. 


For CMD53, 55 as of Serial No. 837176 and 
CMD65 only 


Opt. U20 


A special RF converter for the CMD53/55 enables handover between GSM900 and GSM 1800/1900 while 
maintaining the BCCH in the band (lower/upper) in which the handover was initiated. Standard 
in current version of CM D55. 


For older CMD53 in conjunction with 
Opt UlO only 


Opt. U5 


GSM time synchronization signal and demodulated 1 and Q signals are copied from the 
multifunction connector to three BNC connectors at the rear panel. 


Not compatible with instruments upgrades 
Opt U56. Factory installation 


Opt use 


Upgrade to support DECT in CMD53/55 multiband testers. 


See under Opt U5. Factory installation 


Optuei 


Frequency extension upgrade covering "DEQ Latin America," for CMD60 and CMD65. 


For D version hardware only. Factory installation 


Opt. U65 


GSM multiband upgrade for CMD60. Functionality comparable to CMD6. 


Factory installation 




Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 



Recommended instruments and options 

Development & QA Production High-end service Service 



OptBI 


X 


X 


X 


+*2 


OptB2 


+ 


X 


+« 


X 


Opt B4 


+ 


+ 


+ 


+ 


Opt B51 


+ 


+ 


+ 


X 


OptB17 


+ 


X 


X 


X 


Opt B41 


+ 


+ 


+ 


X 


Opt B43 


+ 


+ 


+ 


X 


Opt B6I 


+ 


+ 


. 


. 


Opt B62 


-I- 


+ 


+ 


+ 


OptK43 


+ 


+ 


+ 


X 


Opt UlO 


- 


- 


X 


X 


Opt Ull 


+ 


+ 


+ 


+ 


0ptU13 


X 


+ 


X 


X 


OptU20 


+ 


+ 


+ 


X 


+ highly recommended 
X recommended 
- not recommended 

External frequency reference may be used, if available. 

One of two OCXOs should be installed to ensure high frequency accuracy. 





DIGITAL RADIOCOMMUNICATION TESTERS 
CMD 53 
CMD 55 

Includes: Power Cord, Operating Manual, Fuses, 
Calibration with Certificate CMD-CAL. 

RECOMMENDED ACCESSORIES 

GSM Test SIM - (Essential for BER measurements). 

Order CRT-Z2. 

Formatted Memory Card - (Opt. B62 required). 
Order CMD-Zl. 

Shielded Chamber - With antenna coupler for 
mobile radio. Order CTD-ZIO. 



For your local Tektronix representative see the list in 
the back of this catalog or outside the U.S. call: 
1-503-627-1916, inside the U.S. call: 1-800-426-2200. 

C€ 



GPIB 

IEEE4U 



Product(s) complies with IEEE Standard 488.2-1987, 
RS-232-C, and with Tektronix Standard Codes and Formats. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality system complies with 
the DIN ISO 9001 standard and has been 
certified by DQS (German Association for the 
Certification of Quality Systems). 



www.tektronix.com/Measurement/commtest/ 



WIRELESS COMMUNICATION TEST SETS 279 








Features - Benefits 



Screen, Diagnose and Facilitate 
Repair of GSM/PCS 1900 Mobiles 

Light Weight and Small Size for 
Stationary, Portable and Mobile Use 

Comprehensive Mobile Phone 
Testing 

High Measurement Accuracy 



Applications 



Mobile Phone Testing 
Network Operator Repair Centers 
Independent Dealerships 
Central Repair Deports 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



CTS 55 Digital Radio Tester 

The CTS 55 Digital Radio Tester is a compact 
imit for testing GSM, DCS 1800 and PCS 1900 
mobile phones. 

THREE STEPS TO REPAIR 

With an ideal combination of Quick, Auto and 
Manual Test, the CTS 55 caters to all steps in the 
process. Quick Test allows the operator to quick- 
ly check the true status of returned phones. Auto 
Test provides for fast diagnosis of the faulty 
parameter. Manual Test allows the operator to 
concentrate on a particular parameter during the 
repair phase. 



ALL THE NEEDED MEASUREMENTS 

The CTS provides the following measurement 
and test functions: 

► Call setup and cleardown (incoming and out- 
going) 

► Free selection of channels 

► Power and channel change 

► Echo test 

► Power measurement 

► Receiver sensitivity test through bit error rate 
measurement as well as RxLev and RxQual 

► Phase and frequency error 

► Dynamic range for measuring power ramp, 
GSM > 55 dB 



Ordering Information 



For price information: 

Outside the U.S. contact your local Tektronix representative, 

as 55 

Digital Radio Tester. 

Includes: Power Cord, Operating Manual. 

as 55 OPTIONS 

Opt. B1 - OCXO 2 X lO'Vyear Reference Oscillator. 

Opt. B7 - Module Test and Output RF. 

Opt. K6 - Remote Control support via RS232. 



inside the U.S. see the price list in the back of this catalog. 

MEASUREMENT SERVICE OPTIONS 
Opt. C3 - Three years of Calibration Services. 

Five years of Calibration Services. 

Opt. D1 - Cal Data Report. 

Opt. 03 - Test Data (requires Opt. C3). 

Opt. R3 - Repair warranty extended to cover three years. 

RECOMMENDED ACCESSORIES 
GSM Test SIM - Order CRT-Z2. 

Standard PC Keyboard - Order PSA-Z2. 



WIRELESS COMMUNICATION TEST SETS 



280 



www.tektronix.com/Measurement/comnite$t/ 






Applications 



Communications Test Sets 

CM D57 




Features - Benefits 



Complete Range of Transmitter and 
Receiver Measurements 

Large Illuminated LCD Display for 
Fast Reading of Parameters and 
Measured Values 

Menu-guided User Interface for 
Quick Tests as Well as for In-depth 
Analysis 

Softkey Control with Display of All 
the Important Parameters Enabling 
Operator to Work Error-free 

Extremely Short Setting and 
Measuring for Both Manual and 
Remote Control via IEEE Bus 



GSM 900, DCS 1800, and PCS 
1900 Base Station Measurements 

Manufacturing, Installation, and 
Maintenance 



For your local Tektronix 
representative see the list in 
the back of this catalog or 
outside the U.S. call: 
1-503-627-1916, 
inside the U.S. call: 
1-800-426-2200. 




Product(s) complies with 
IEEE Standard 488.2. 

ROHDE&SCHWARZ 

Rohde & Schwarz' quality 
system complies with the DIN 
ISO 9001 standard and has 
been certified by DQS 
(German Association for the 
Certification of Quality 
Systems). 



Abis Control Options Available 
In-service Testing Option 



CMD 57 Digital 
Radiocommunication Tester 

The CMD 57 Digital Radiocommunication Tester 
is a compact unit for testing GSM, DCS 1800 and 
PCS 1900 base stations (BTS) and BTS modules. 
It allows measurements on base station transmit- 
ters and receivers without affecting calls in 
progress. With the in-service test option, meas- 
urements can be made without taking a cell site 
out of service. 

DETAILED KNOWLEDGE NOT REQUIRED 

The CMD 57 is easy to use and is equally at 
home in production, installation and service 
environments. Ease of use goes beyond the front 
panel. All parameters can be individually modi- 
fied in the configmation menu to allow easy 
adaptation to stringent user-specific tolerances. 
Any parameters that have modified with respect 
to the default standard specifications are clearly 
shown on the display. 

Additional attenuators, cables, and amplifiers are 
often required for connecting to the BTS. The 
effect of these additions are taken into account 
by the CMD 57 when calculating the measure- 
ment results. 



TEST YOUR TRANSMITTER 

The following GSM/DCS/PCS specific measure- 
ments are available for transmitter testing: 

► Mean RF carrier power 

► Power ramping 

► Phase/frequency error 

► Spectrum due to modulation 

► Spectrum due to switching 
Measurements results on the transmitter’s traffic 
channel (TGH) are obtained by simply switching 
to the corresponding menu. The results are 
graphically displayed along with applicable sta- 
tistical functions. 

... AND RECEIVERS TOO 

You can also make the required tests on 
receivers. 

► Bit error rate (BER) 

► Adjacent time slot rejection 

PLUS MANY OTHER MEASUREMENTS 

You can also make may other base station meas- 
urements with the GMD 57 including: 

► Echo test 



www.tektronix.com/Measurement/comnitest/ 



WIRELESS COMMUNICATION TEST SETS 281 





Communications Test Sets 

CMD57 



► Module tests without signaling or 
time synchronization 

► Alignment using built-in multifunc- 
tion RF generator 

► AF measurements with optional fre- 
quency counter 



Characteristics 



environmental 

Rated Temperature Range - 0 to -t-AS^C 

(to DIN lEC 68-2-1/2). 



Storage Temperature Range - -40 to +60°C. 
Electromagnetic Compatibility - Complies 
with requirements of European EMC dirertive 
(89/336/EEC). 

Mechanical Resistance - 

Sine vibration: DIN lEC 68-2-6, 5 to 55 Hz, 
amplitude 0.15 mm, two cycles; 

Random vibration: DIN 40046, part 24, 10 to 
300 Hz, 10 ms/s2 rms, 5 min/axis; 

Shock: To MIL-STD-810D, 400 m/s2, shock 
spectrum in six main axes. 

POWER REQUIREMENTS 

Line Voltage - 100 to 120 V AC ±10%; 200 to 



240 VAC ±10%. 

Line Frequency - 50 to 400 Hz ±5%. 
Power Consumption (without options) - 

Approx. 85 W. 

Safety -UL31 11, CSAIOIO.I. 



Physical Characteristics 



Dimensions 


mm 


in. 


Height 


192 


7.6 


Width 


435 


17.1 


Depth 


363 


14.3 


WeigM 


Itg 


lb. 


Without options 


Approx. 14 


30.8 



Ordering Information 



For price information: Outside the U.S. contact your local Tektronix representative, inside the U.S. see the price list in the back of this catalog. 

Opt. K13 - NMC Abis Control Software 



CMD57 

Digital Radiocommunication Tester. 